Cyclone separator design
Flowrate : 500 cfm
Estimate DC :
Dc = sqrt ( 8. Q/ 2400) [feet]
Dc = 1.29 feet= 15.49 inch= 16.00 inch (rounded)
Find another parameter :
BC = Dc/4 = 4.00 inch
Hc = Dc/2 = 8.00 inch
De = Dc/1.6 = 10.00 inch
Lc = Dc = 16.00 inch
Sc = Dc/1.6 = 10.00 inchSc = Dc/2 = 8.00 inch
Zc = 2Dc = 32.00 inch
Jc = Dc/2 = 8.00 inch