2
Cyclone separator design Flowrate : 500 cfm Estimate DC : Dc = sqrt ( 8. Q/ 2400) [feet] Dc = 1.29 feet = 15.49 inch = 16.00 inch (rounded) Find another parameter : BC = Dc/4 = 4.00 inch Hc = Dc/2 = 8.00 inch De = Dc/1.6 = 10.00 inch Lc = Dc = 16.00 inch Sc = Dc/1.6 = 10.00 inch Sc = Dc/2 = 8.00 inch Zc = 2Dc = 32.00 inch Jc = Dc/2 = 8.00 inch

Upload: mamank-ira-sudrajat

Post on 29-Nov-2015

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cylone Design

Cyclone separator design

Flowrate : 500 cfm

Estimate DC :

Dc = sqrt ( 8. Q/ 2400) [feet]

Dc = 1.29 feet= 15.49 inch= 16.00 inch (rounded)

Find another parameter :

BC = Dc/4 = 4.00 inch

Hc = Dc/2 = 8.00 inch

De = Dc/1.6 = 10.00 inch

Lc = Dc = 16.00 inch

Sc = Dc/1.6 = 10.00 inchSc = Dc/2 = 8.00 inch

Zc = 2Dc = 32.00 inch

Jc = Dc/2 = 8.00 inch