d i s r u pt i n g t h e w o r l d o f c o a t i n g s t o
TRANSCRIPT
Hood
SpeedCoating speed 200m2/hour with 200µm epoxyCrawler speed 0 – 0,3m/s
Coating coverage
Layers & Paints
Control report
80%. At least 80cm from obstacles
Min 75µm dry per layer – max 900µm dry per layer2K protective coatings, mixing ratio from 1:1 to 1:10
Layer thickness per position on tank
Less than 1% paint outside hood (clearance of hood is +-20mm)
Atomization system This system consists out of a 2K pump. Max static pressure: 530 bar
Coating method Depending on the paint and layer thickness requirement of the client thespray head settings and coating method (required overlap) can bedetermined
ATEX Suction system and paint system is EX certified
Needed from the cl ient380V/15kW Bracket for fall arresters and electrical winch Paint Optional: compressed air at 10 bars
Limitat ions
Tank limitations: Max height of tank 30m. Minimum tank diameter20m→Smaller diameters will be evaluated case by case. There needs to bespace for equipment next to the tank Environment limitations: No rain, wind max 4bft
Operators ' requirement 10Q training and safety certificates required by the terminal
MaintenanceDaily and weekly maintenance to be done by client. Monthly and yearly maintenance to be done by Qlayers
10Q™ robot Disrupting the world of coating storage tanks
Qlayers' 10Q robots coatstorage tanks with aninnovative applicationsystem that makes thecoating processes faster,safer and more efficient.
If you are interested toknow how our automatedrobotic solution canbenefit your business,please contact us at:
(+31)6-834 576 94
www.qlayers.com
General specif ications