d i s r u pt i n g t h e w o r l d o f c o a t i n g s t o

1
Hood Speed Coating speed 200m2/hour with 200µm epoxy Crawler speed 0 – 0,3m/s Coating coverage Layers & Paints Control report 80%. At least 80cm from obstacles Min 75µm dry per layer – max 900µm dry per layer 2K protective coatings, mixing ratio from 1:1 to 1:10 Layer thickness per position on tank Less than 1% paint outside hood (clearance of hood is +-20mm) Atomization system This system consists out of a 2K pump. Max static pressure: 530 bar Coating method Depending on the paint and layer thickness requirement of the client the spray head settings and coating method (required overlap) can be determined ATEX Suction system and paint system is EX certified Needed from the client 380V/15kW Bracket for fall arresters and electrical winch Paint Optional: compressed air at 10 bars Limitations Tank limitations: Max height of tank 30m. Minimum tank diameter 20m Smaller diameters will be evaluated case by case. There needs to be space for equipment next to the tank Environment limitations: No rain, wind max 4bft Operators' requirement 10Q training and safety certificates required by the terminal Maintenance Daily and weekly maintenance to be done by client. Monthly and yearly maintenance to be done by Qlayers 10Q™ robot Disrupting the world of coating storage tanks Qlayers' 10Q robots coat storage tanks with an innovative application system that makes the coating processes faster, safer and more efficient. If you are interested to know how our automated robotic solution can benefit your business, please contact us at: [email protected] (+31)6-834 576 94 www.qlayers.com General specifications

Upload: others

Post on 20-May-2022

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: D i s r u pt i n g t h e w o r l d o f c o a t i n g s t o

Hood

SpeedCoating speed 200m2/hour with 200µm epoxyCrawler speed 0 – 0,3m/s

Coating coverage

Layers & Paints

Control report

80%. At least 80cm from obstacles

Min 75µm dry per layer – max 900µm dry per layer2K protective coatings, mixing ratio from 1:1 to 1:10

Layer thickness per position on tank

Less than 1% paint outside hood (clearance of hood is +-20mm)

Atomization system This system consists out of a 2K pump. Max static pressure: 530 bar

Coating method Depending on the paint and layer thickness requirement of the client thespray head settings and coating method (required overlap) can bedetermined

ATEX Suction system and paint system is EX certified

Needed from the cl ient380V/15kW Bracket for fall arresters and electrical winch Paint Optional: compressed air at 10 bars

Limitat ions

Tank limitations: Max height of tank 30m. Minimum tank diameter20m→Smaller diameters will be evaluated case by case. There needs to bespace for equipment next to the tank Environment limitations: No rain, wind max 4bft

Operators ' requirement 10Q training and safety certificates required by the terminal

MaintenanceDaily and weekly maintenance to be done by client. Monthly and yearly maintenance to be done by Qlayers

10Q™ robot Disrupting the world of coating storage tanks

Qlayers' 10Q robots coatstorage tanks with aninnovative applicationsystem that makes thecoating processes faster,safer and more efficient.

If you are interested toknow how our automatedrobotic solution canbenefit your business,please contact us at:

[email protected]

(+31)6-834 576 94

www.qlayers.com

General specif ications