dab pump kv ad 3 - 6 -10 info@lenntech · kv ad 3 - 6 -10 sets with active driver 3-6-10 at...
TRANSCRIPT
![Page 1: DAB pump KV AD 3 - 6 -10 info@lenntech · KV AD 3 - 6 -10 SETS WITH ACTIVE DRIVER 3-6-10 AT CONSTANT PRESSURE. DAB PUMPS reserves the right to make modifications without notice PRESSURE](https://reader030.vdocument.in/reader030/viewer/2022013022/5f8e264cc1474d618671dbc8/html5/thumbnails/1.jpg)
DAB PUMPS reserves the right to make modifications without notice
PRES
SURE
UNI
TS
DAB pump KV AD 3 - 6 -10SETS WITH ACTIVE DRIVER 3-6-10 AT CONSTANT PRESSURE
Pressure units, particularly suitable for domestic applications and small systems for civil or industrial uses, irrigation systems and washing installations.CONSTRUCTION FEATURES - COMPONENTS• 2-3 KV centrifugal multistage electric pump on a vertical axis• Galvanized steel skid complete with four rubber antivibration feet for 2 or 3-pump units.• Suction and delivery manifold in galvanized steel for 2 or 3-pump units• Ball valves on the suction and delivery pipe union of each single pump
• Check valves on suction port of each pump• 2 Galvanized steel plugs for manifolds for 2 or 3-pump units• Radial pressure gauge with shut-off valve for 2 or 3-pump units.• 1 Active Driver module on the discharge line of each pump
TECHNICAL DATA
MODEL CODE
1 KV A.D. 3/12 M 500390010
1 KV A.D. 6/11 M 500390020
1 KV A.D. 10/6 M 500390030
2 KV A.D. 3/10 T/ N 60121952
2 KV A.D. 3/12 T / N 500390110
2 KV A.D. 6/7 T / N 500390170
2 KV A.D. 6/9 T / N 500390160
2 KV A.D. 6/11 T / N 500390120
2 KV A.D. 10/4 T / N 500390140
2 KV A.D. 10/5 T / N 500390150
2 KV A.D. 10/6 T / N 500390130
2 KV A.D. 10/8 T 500390180
3 KV A.D. 3/12 T / N 500390210
3 KV A.D. 6/11 T / N 500390220
3 KV A.D. 10/6 T / N 500390230
3KV A.D. 10/8 T 60118791
ELECTRICAL DATA HYDRAULIC DATAØ WEIGHT
KgVOLTAGE 50 HzP2
NOMINAL Qm3/h
Hm A MkW HP
1 X 230 V ~ 1,5 2 0,5-7 100-20 1”¼ 1”¼ 39
1 X 230 V ~ 1,85 2,5 0,5-8 90-25 1”¼ 1”¼ 38
1 X 230 V ~ 1,85 2,5 0,5-13 55-20 1”¼ 1”¼ 38
3 X 230 V ~ 2 x 1,1 2 x 1,5 0,5-14 80-20 2” 2” 120
3 X 230 V ~ 2 x 1,5 2 x 2 0,5-14 100-20 2” 2” 125
3 X 230 V ~ 2 x 1,1 2 x 1,5 0,5-16 60-20 2” 2” 121
3 X 230 V ~ 2 x 1,5 2 x 2 0,5-16 85-25 2” 2” 125
3 X 230 V ~ 2 x 1,85 2 x 2,5 0,5-16 90-25 2” 2” 128
3 X 230 V ~ 2 x 1,1 2 x 1,5 0,5-26 35-20 2” 1/2 2” 1/2 117
3 X 230 V ~ 2 x 1,5 2 x 2 0,5-26 50-25 2” 1/2 2” 1/2 120
3 X 230 V ~ 2 x 1,85 2 x 2,5 0,5-26 55-20 2” 1/2 2” 1/2 126
3 X 400 V ~ 2 x 2,2 2 x 3 0,5-26 70-30 2” 1/2 2” 1/2 132
3 X 230 V ~ 3 x 1,5 3 x 2 0,5-21 100-20 2” 1/2 2” 1/2 150
3 X 230 V ~ 3 x 1,85 3 x 2,5 0,5-24 90-25 2” 1/2 2” 1/2 160
3 X 230 V ~ 3 x 1,85 3 x 2,5 0,5-39 55-20 DN 80 DN 80 200
3 X 400 V ~ 3 x 2,2 3 x 3 0,5-39 70-30 DN 80 DN 80 220
[email protected]. +31-15-261.09.00Fax. +31-15-261.62.89
![Page 2: DAB pump KV AD 3 - 6 -10 info@lenntech · KV AD 3 - 6 -10 SETS WITH ACTIVE DRIVER 3-6-10 AT CONSTANT PRESSURE. DAB PUMPS reserves the right to make modifications without notice PRESSURE](https://reader030.vdocument.in/reader030/viewer/2022013022/5f8e264cc1474d618671dbc8/html5/thumbnails/2.jpg)
DAB PUMPS reserves the right to make modifications without notice
PRES
SURE
UNI
TS
2 KV AD 3 2 KV AD 6
0 Q m3/h2 4 6 8 10 12 140
20
40
60
80
100
120
140
160
180
Hm
0
200
400
600
800
1000
1200
1400
1600
1800
PkPa
0 40 80 120 160 200 240 Q l/min
0 1 2 3 4 Q l/s
0
100
200
300
400
500
600
H ft
0 10 20 30 40 50 60 Q US gpm
0 10 20 30 40 50 Q IMP gpm
2 KV 3/12
2 KV 3/10
0 Q m3/h4 8 12 16 20 24 280
10
20
30
40
50
60
70
Hm
0
100
200
300
400
500
600
700
PkPa
0 80 160 240 320 400 480 Q l/min
0 2 4 6 8 Q l/s
0
40
80
120
160
200
240
H ft
0 20 40 60 80 100 120 Q US gpm
0 20 40 60 80 100 Q IMP gpm
2 KV 10/8
2 KV 10/6
2 KV 10/5
2 KV 10/4
0 Q m3/h2 4 6 8 10 12 14 16 180
20
40
60
80
100
120
Hm
0
200
400
600
800
1000
1200
PkPa
0 40 80 120 160 200 240 280 Q l/min
0 1 2 3 4 5 Q l/s
0
50
100
150
200
250
300
350
400
H ft
0 10 20 30 40 50 60 70 Q US gpm
0 10 20 30 40 50 60 Q IMP gpm
2 KV 6/11
2 KV 6/9
2 KV 6/7
2 KV AD 10
3 KV AD 3 3 KV AD 6
0 Q m3/h3 6 9 12 15 18 210
20
40
60
80
100
120
140
160
180
Hm
0
200
400
600
800
1000
1200
1400
1600
1800
PkPa
0 60 120 180 240 300 360 Q l/min
0 1,5 3 4,5 6 Q l/s
0
100
200
300
400
500
600
H ft
0 15 30 45 60 75 90 Q US gpm
0 15 30 45 60 75 Q IMP gpm
3 KV 3/12
0 Q m3/h6 12 18 24 30 36 420
10
20
30
40
50
60
70
Hm
0
100
200
300
400
500
600
700
PkPa
0 120 240 360 480 600 720 Q l/min
0 3 6 9 12 Q l/s
0
40
80
120
160
200
240
H ft
0 30 60 90 120 150 180 Q US gpm
0 30 60 90 120 150 Q IMP gpm
3 KV 10/8
3 KV 10/6
0 Q m3/h3 6 9 12 15 18 21 24 270
20
40
60
80
100
120
Hm
0
200
400
600
800
1000
1200
PkPa
0 60 120 180 240 300 360 420 Q l/min
0 1,5 3 4,5 6 7,5 Q l/s
0
50
100
150
200
250
300
350
400
H ft
0 15 30 45 60 75 90 105 Q US gpm
0 15 30 45 60 75 90 Q IMP gpm
3 KV 6/11
3 KV AD 10
1 KV AD 3 1 KV AD 6 1 KV AD 10
0 Q m3/h1 2 3 4 5 6 70
20
40
60
80
100
120
140
160
180
Hm
0
200
400
600
800
1000
1200
1400
1600
1800
PkPa
0 10 20 30 40 50 60 70 80 90 100 110 120 Q l/min
0 0,5 1 1,5 2 Q l/s
0
100
200
300
400
500
600
H ft
0 5 10 15 20 25 30 Q US gpm
0 5 10 15 20 25 Q IMP gpm
1 KV 3/12
0 Q m3/h1 2 3 4 5 6 7 8 90
20
40
60
80
100
120
Hm
0
200
400
600
800
1000
1200
PkPa
0 20 40 60 80 100 120 140 Q l/min
0 0,5 1 1,5 2 2,5 Q l/s
0
50
100
150
200
250
300
350
400
H ft
0 5 10 15 20 25 30 35 Q US gpm
0 5 10 15 20 25 30 Q IMP gpm
1 KV 6/11
0 Q m3/h2 4 6 8 10 12 140
10
20
30
40
50
60
70
Hm
0
100
200
300
400
500
600
700
PkPa
0 20 40 60 80 100 120 140 160 180 200 220 240 Q l/min
0 1 2 3 4 Q l/s
0
40
80
120
160
200
240
H ft
0 5 10 15 20 25 30 35 40 45 50 55 60 Q US gpm
0 5 10 15 20 25 30 35 40 45 50 Q IMP gpm
1 KV 10/6
KV AD 3 - 6 -10SETS WITH ACTIVE DRIVER 3-6-10 AT CONSTANT PRESSURE
![Page 3: DAB pump KV AD 3 - 6 -10 info@lenntech · KV AD 3 - 6 -10 SETS WITH ACTIVE DRIVER 3-6-10 AT CONSTANT PRESSURE. DAB PUMPS reserves the right to make modifications without notice PRESSURE](https://reader030.vdocument.in/reader030/viewer/2022013022/5f8e264cc1474d618671dbc8/html5/thumbnails/3.jpg)
DAB PUMPS reserves the right to make modifications without notice
PRES
SURE
UNI
TS
DIMENSIONS
KV AD 3 - 6 -10SETS WITH ACTIVE DRIVER 3-6-10 AT CONSTANT PRESSURE
R
412
H2
+ 4
2060
circa 129
H2
+ 4
80
EP 1
155
195
PUMP PERFORMANCE
R R
300
500570
H2
+ 4
8012
5
190
H2
+ 7
05
EP 1
PUMP PERFORMANCE
R R
600
800570
H2
+ 4
8012
5
190
H2
+ 7
05
EP 1
R