dan cheng 6/11/2015 qxf coil measurements plan at lbnl
TRANSCRIPT
![Page 1: Dan Cheng 6/11/2015 QXF coil measurements plan at LBNL](https://reader036.vdocument.in/reader036/viewer/2022070410/56649f255503460f94c3c6bf/html5/thumbnails/1.jpg)
Dan Cheng6/11/2015
QXF coil measurementsplan at LBNL
![Page 2: Dan Cheng 6/11/2015 QXF coil measurements plan at LBNL](https://reader036.vdocument.in/reader036/viewer/2022070410/56649f255503460f94c3c6bf/html5/thumbnails/2.jpg)
QXF Coil CMM measurements at LBNL 2
Cross Section Measurement Locations
6/11/2015
• Same axial locations as being performed at BNL– With the addition of one more measurement
location at 742.24 mm (29.22”) for the SG location
![Page 3: Dan Cheng 6/11/2015 QXF coil measurements plan at LBNL](https://reader036.vdocument.in/reader036/viewer/2022070410/56649f255503460f94c3c6bf/html5/thumbnails/3.jpg)
QXF Coil CMM measurements at LBNL 3
CMM Measurements
6/11/2015
• LBNL uses Zeiss Accura for CMM, using built-in Calypso for post-processing – But we have not been able to weight different surfaces for alignment– All surfaces “best-fit” to reference geometry with equal weight
![Page 4: Dan Cheng 6/11/2015 QXF coil measurements plan at LBNL](https://reader036.vdocument.in/reader036/viewer/2022070410/56649f255503460f94c3c6bf/html5/thumbnails/4.jpg)
QXF Coil CMM measurements at LBNL 4
Post-processing Comparisons
6/11/2015
• Prior to identification of the asymmetry issue, all HQ magnets were built using data processed by the Calypso software for overall coil size
• LBNL now has the ability to post-process, with weighting, with both Polyworks and Spatial Analyzer
• We are performing an apples-to-apples comparison– BNL Coil measurement data (Faro Arm)– LBNL (Zeiss) measurement data, processed with:
• Calypso (for historical comparison)• SA (for comparison with BNL processing)• Polyworks (additional process check)
![Page 5: Dan Cheng 6/11/2015 QXF coil measurements plan at LBNL](https://reader036.vdocument.in/reader036/viewer/2022070410/56649f255503460f94c3c6bf/html5/thumbnails/5.jpg)
QXF Coil CMM measurements at LBNL 5
Fitting the profiles
6/11/2015
• Two methods per cross section:– “Global” best fit
• Objective is to compare with prior Zeiss/Calypso post processing
– “Weighted” best fit• Objective: to compare
with BNL data and to determine coil asymmetry
Global:Midplanes + OD + Alignment Key
Weighted:OD + Alignment Key
![Page 6: Dan Cheng 6/11/2015 QXF coil measurements plan at LBNL](https://reader036.vdocument.in/reader036/viewer/2022070410/56649f255503460f94c3c6bf/html5/thumbnails/6.jpg)
QXF Coil CMM measurements at LBNL 6
Status
6/11/2015
• Data is being processed on a few cross sections before applying to the rest of the cross sections and coils
• All four coils will have to be measured again next week, since axial locations of cross sections did not match those made by BNL