Visit our Homepage: compressors.danfoss.com DEHC.PI.100.K1.02/520N0651 06-2008Technical data subject to change without prior notice1/2
InstructionsDanfoss One Wire/LIN
Gateway 105N9501
8238-35
Gateway 105N9501 package contains:Pos. Spare part
numberDescription
1 105N9522 Serial RS232 Cable with USB Voltage Supply2 Standard USB 2.0 A/B Cable3 105N9523 One Wire/LIN Gateway Communication Cable BD350GH
4Danfoss One Wire/LIN GatewayLength, Height: 55 mm / Width: 82 mm / Depth: 80 mm
CD-ROM Future Technology Devices International Ltd. USB Driver
approx. 2500 mm
approx. 1800 mm
approx. 1000 mm
on
ly fo
r su
pp
ly
8673
1
2
3
USBDanfoss One Wire
LIN Gateway One Wire/ LINUSB Code n o.: 105N9501
RS232/485USB 2.0
Electronics(One Wire / LIN)
RS232RS485
Tx Rx
8676-3
32
4
USB Connection
COM
Danfoss One WireLIN Gateway One Wire
/ LINUSB Code n o.: 105N9501
RS232/485USB 2.0
Electronics(One Wire / LIN)
RS232RS485
Tx RxUSB(only for supply)
8676-2
1
3
4
COM Connection
Visit our Homepage: compressors.danfoss.com DEHC.PI.100.K1.02/520N0651 06-2008Technical data subject to change without prior notice2/2
InstructionsDanfoss One Wire/LIN
Gateway 105N9501
8238-35
RS232/485 Selection via internal DIP Switch:
Default: RS232 or USB <-> Danfoss One Wire/LINDIP-Switch SW1 Settings
1 2 3 4 5 6 7 8off off off off off on off off
Option: RS485 <-> Danfoss One Wire/LINDIP-Switch SW1 Settings
1 2 3 4 5 6 7 8on on on on on on off off
Bias resistors620 Ω
Terminal resistor 120 Ω RxTx+ (A) RxTx- (B)
D9-Sub-Pin-no: RxTx+ (A) RxTx- (B) Power Input+5 V / ≤ 100 mA GND
1 6 9 5
1 2 3 4 5 6 7 8
SW1 DIP-switch placement inside the Danfoss One Wire/LIN Gateway8675
ON
COM Connection