danger laser beam · 2020. 9. 17. · danger laser beam. apply to other type of metering point (...
TRANSCRIPT
![Page 1: DANGER LASER BEAM · 2020. 9. 17. · DANGER LASER BEAM. APPLY TO OTHER TYPE OF METERING POINT ( any service) BANDSTAND / ROTUNDA / SPORTS FIELD STANDS / OTHER PARK BUILDING Traffic](https://reader035.vdocument.in/reader035/viewer/2022071413/610c7af609edb360e824f66b/html5/thumbnails/1.jpg)
APPLY TO OTHER TYPE OF METERING POINT ( any service)
BANDSTAND / ROTUNDA / SPORTS FIELD STANDS /OTHER PARK BUILDING
Traffic Lights / Traffic Light Controller /Variable Speed Sign / Traffic Signal
Public Transport (bus stop, tram stop, railway station, taxi rank, ferry wharf)
Transformer / Kiosk / Pad Mount Sub-station / Pole Mount Transformer
Links / Link Pole / MV / HV Links / ABC Links / Dynamic Switch / Airbrake Switch / Isolator
Water Infrastructure (storage, pumps, valves water supply, waste water, sewerage stations)
Natural Gas Infrastructure
Camera (security / traffic)
Bridge control, swing bridge, traffic control gates, railway boom gates)
Mobile Phone Tower / radio antenna
Street Lighting Pole / street light controller
Unmanned (council) car park
POINT OF SALE DEVICE (vending machine, ticket machine)
Symbol to be used when replacing/removing existing network
ATMATM
DEPTHALIGN
FSA Boundary
FSAM Boundary
FDA Boundary
CABLE CONFIGURATIONCABLE TYPE:
CABLES DIVIDE INTO FOLLOWING CATEGORIES AND ARECOLOUR CODED:TRANSIT CABLESDISTRIBUTION CABLESLOCAL CABLESTETHER CABLESLEAD IN (DROP) CABLES
CABLE SIZE:
CABLE SIZE IS THE TOTAL NUMBER OF OPTICFIBRES IN THE CABLE AND IS DETERMINED BY ANUMBER FOLLOWED BY F (FIBRE) OR R (RIBBON) IN THE MIDDLEOF THE LINE TYPE
CABLE LOCATION:CABLE LOCATIONS DETERMINES WHERE THECABLE IS USED AS PER BELOW:
IN-CONDUITAERIALBURIED
EXAMPLE:
144 FIBRE AERIAL LOCAL CABLE1 FIBRE BURIED DROP CABLE432 FIBRE IN-CONDUIT TRANSIT CABLE
LINE TYPES ARE CATEGORIZED INTO 3 TYPES:
1- IN-CONDUIT: (XXXF) 312F , ...
2- AERIAL: (XXXF_A) 144_A , ...
3- BURIED: (XXXF_B) 12_B , ...
COLOUR NO: 1COLOUR NO: 190COLOUR NO: 4COLOUR NO: 3COLOUR NO: 5
312F288F144F12F
1F
288F144F
96F
144F1F 1F
48F
576F
CONDUITS AND DUCTS ARE IN LAYER :< L460 NBN Support - Underground >AND TERMINOLOGY CATEGORIZED INTO TWO GROUPS INTHE DRAWING AS PER BELOW:1- DUCT USED WITH LOCAL NETWORK
2-CONDUIT USED WITH LEAD-IN DROPSATTRIBUTES ATTACHED ARE AS SHOWN
CONDUIT SIZE CONDUIT LENGTH
CONDUIT CONFIGURATION
DEPTH OVER ALIGNMENT SYMBOL TO BE USED WITH EVERY MARKER POST
ASSISTANCE TELEPHONES (EG ELEVATOR AND ROADSIDE PHONES)
PRIVATELY OPERATED PAYPHONESPOP
APS
26.5P100
--
CAR
LIT
MOB
CTL
CAM
GAS
WAT
SWT
PBT
TRF
PSD
PRK
ATM
MET
PIT-ID9
PIT-ID5
LASER BEAMDANGER
Fibre Distribution Hub-FDH Cabinet with Cabinet ID shown
Splice Joint on a Transit Cable (TJL)
Splice Joint on a Local Cable (LJL)
Zone Terminal / Splice Joint (AJL)
Splice Joint on a Distribution Cable (DJL)
Splice Joint on a Tether Cable (MJL)
FDH-ID
MJL-ID
PIT-ID9
PIT-ID5
PIT-ID2
AJL-ID
LJL-ID
DJL-ID
TJL-ID
Service Drop Access Pit
Network Boundary/Local Network Pit (Single Lid)
Fibre Distribution Hub (FDH) Pit
Distribution/Local Network Connection PitPIT-ID8
(650mmX280mmX565mm)
(700mmX450mmX650mm)
(1360mmX555mmX860mm)
(2000mmX555mmX900mm)
PIT-ID6 Distribution/Local Network Connection Pit (Dual Lid)
(1360mmX555mmX650mm)
nbn NTDNTDNBN Optional Battery Backup UnitOBBU
PDH nbn Premises Distribution Hub
CTLFDT
FIP
nbn Cable Transition Location
nbn Fibre Distribution Terminal
nbn NTD Fire Indicator Panel
Riser Riser
Network Access Point (NAP)
Multiport (MPT)n is the number of ports (eg 4,6,8,12)Multiport (MPT)
MPT-IDN
NAP-IDN
Penetration
Shared Trench
Premise Connection Device (PCD)
Pole (showing pole identity)POLE-ID
CABLE TRAY:
NBN MARKER POSTMARKER POST TO BE NUMBERED< _>
Example of Telstra Major Conduit Layout withProposed duct marked to be used by NBN
Telstra exchange
Existing Telstra Pit ( 2,3,4,5,6,7,8,9 )5
LIFTAP
nbn NTD LIFT
Access Panel
SEC nbn NTD Security
CET nbn Communications Earth Terminal
Example of descriptor box that will show thetype of work and the quantity involved
DESQTY
nbn manhole
Existing Telstra manhole
Multi Dwelling Unit (MDU)RCXX138A
FAN Fan Access Node site (FAN)AAAA
STAGE 1 STAGE 2
STAGE 3STAGE 4
STAGE 5FSA:
STATE: REGION:
SAM:
DRAFTER
ADA:
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
DRAWING TITLE:
PROJECT No:
SCALE SHEET No. REV.
QUALITY RECORD :
APPROVED
NBNCO APPROVAL RECORD:
DD
AB
WD
REV DATE DESCRIPTION
SIGNATURE DATE
NBNCO DISCLAIMER
CADREF No:
NN KEY PLAN
OF
STRICTLY CONFIDENTIAL
THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE USE OFNBNCO LIMITED (ABN 86 136 533 741) FOR USE IN MAINTAININGNBNCO FACILITIES. IT HAS NOT BEEN CREATED FOR ANY OTHERUSE. IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS. NOWARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE ORCOMPLETE.
ENABLE#:
J&P RICHARDSONINDUSTRIES
NBN Co. PIT & PIPE INFRASTRUCTURETO PROPOSED SUBDIVISIONCASH STREET STAGE 1D'AGUILAR
QLD
STG-W000123258
E20-P.0302698.D.01
N/A 1 3 -
- 25-05-20 M.L./B.H. ORIGINAL ISSUE
![Page 2: DANGER LASER BEAM · 2020. 9. 17. · DANGER LASER BEAM. APPLY TO OTHER TYPE OF METERING POINT ( any service) BANDSTAND / ROTUNDA / SPORTS FIELD STANDS / OTHER PARK BUILDING Traffic](https://reader035.vdocument.in/reader035/viewer/2022071413/610c7af609edb360e824f66b/html5/thumbnails/2.jpg)
FSA:
STATE: REGION:
SAM:
DRAFTER
ADA:
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
DRAWING TITLE:
PROJECT No:
SCALE SHEET No. REV.
QUALITY RECORD :
APPROVED
NBNCO APPROVAL RECORD:
DD
AB
WD
REV DATE DESCRIPTION
SIGNATURE DATE
NBNCO DISCLAIMER
CADREF No:
NN KEY PLAN
OF
STRICTLY CONFIDENTIAL
THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE USE OFNBNCO LIMITED (ABN 86 136 533 741) FOR USE IN MAINTAININGNBNCO FACILITIES. IT HAS NOT BEEN CREATED FOR ANY OTHERUSE. IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS. NOWARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE ORCOMPLETE.
ENABLE#:
J&P RICHARDSONINDUSTRIES
NBN Co. PIT & PIPE INFRASTRUCTURETO PROPOSED SUBDIVISIONCASH STREET STAGE 1D'AGUILAR
QLD
STG-W000123258
E20-P.0302698.D.01
1:500 @ A1 2 3 -
- 25-05-20 M.L./B.H. ORIGINAL ISSUE
INTERCONNECTION BETWEEN PROPOSED NBN CO. NETWORK AND THEINTO THE EXISTING INFRASTRUCTURE AT STATION 2.
EXISTING NETWORK TO BE ORGANISED AND CARRIED OUT BY NBN. CO.3.
2.
SOURCE DOCUMENTSDRG. No.AUTHOR REV. No. DATEM2584E-BASE - STANDARD.ZIP-----
JFP-----
------
28-04-20-----
INTERNALSTEPD
L W
SOURCE DOCUMENTSDRG. No.AUTHOR REV. No. DATE
-
CANCELLING LOT 1 ON RP230991PROPOSED LOTS 1-27
PROPOSED SUBDIVISION
CIVIL CONSULTANT - JFP URBAN CONSULTANTS - 5450 3900SURVEYOR - JFP URBAN CONSULTANTS - 5450 3900
- (CONSTRUCTION) - PETER HARLEY - 3271 2911- (DESIGNER) - MITCHELL LE GRANGE - 3271 2911
GAS - APA GROUP - SILVIA HART - 3215 6655
No OF LOTS:- 27
TARGET DATES
ON SITE CHECKS OF EXISTING SERVICES SHOULD BE
MATERIALS REQ'D - OCTOBER 2020INSTALLATION REQ'D - OCTOBER 2020
ON SITE SERVICE CHECKS
NBN - WORKS CO-ORDINATOR - JOHN CROWLEY - 0408 469 685J&P RICHARDSON
COUNCIL - DIAL BEFORE YOU DIG - 1100DIAL BEFORE YOU DIG - 1100
ARRANGED WITH THE RELEVANT AUTHORITIES LISTED BELOW.
* NBN Co. GUIDELINES FOR DEVELOPERS: NBN-TE-CTO-194 V8.0
THIS WORKS PLAN IS TO BE READ IN CONJUNCTION WITHTHE FOLLOWING NBN Co. MANUAL AND SPECIFICATIONS:
SPECIFICATIONS
1.
4.
NEW RESIDENTIAL SUBDIVISIONORIGIN:NOTES:
P100 TO BE INSTALLED TO BOUNDARY OF DEVELOPMENT
P100 TO BE INSTALLED UP TO BUT NOT CONNECTED
INSTALL LEAD IN PIPE FOR FUTURE STAGE.AND CAPPED FOR FUTURE STAGE EXTENSION.
STAGE 1 STAGE 2
STAGE 3STAGE 4
STAGE 5
DRAINAGE901
RESERVE
AKOO
NAH
WY
HART
LEY
DR
CASH ST
FLINDERS ST
FLIND
ERS
ST
BRAD
MAN
ST
BANK
SIA C
L
1
23
4
56
7
8
9
10
11
12
13
14
15
16
17
1821
22
23
24
25
26
PWR
5
3
5
5
3
3
6
P35
P35
P35
P50
P100P100
P100P100
P100
P100P10
0
P50
PIT-0015
PIT-0025
PIT-0035
PIT-0046
PIT-0
055
PIT-0
062
PIT-0
075
PIT-0
082
PIT-0
095
PIT-0
106
PIT-0
125
PIT-0136
PIT-0
165
PIT-0
175
PIT-0
182
P100
19.7
P100
60.2P100
38.6 P100
66.8
P100
44.8
P5019
P100
33.7
P50 18.8
P100
32.4
P100
18.5
P100
154.1 P100
P100
50.4
P100
43
P100
P100
40.7
P100
29
P50
19.8
29
P202
P202
P202
P202
P202
P202
P202
P202
P202
P202
P202
P202
P202
P202
P202
P2015
P202
P202
P202
P202
P202
P202
![Page 3: DANGER LASER BEAM · 2020. 9. 17. · DANGER LASER BEAM. APPLY TO OTHER TYPE OF METERING POINT ( any service) BANDSTAND / ROTUNDA / SPORTS FIELD STANDS / OTHER PARK BUILDING Traffic](https://reader035.vdocument.in/reader035/viewer/2022071413/610c7af609edb360e824f66b/html5/thumbnails/3.jpg)
FSA:
STATE: REGION:
SAM:
DRAFTER
ADA:
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
DRAWING TITLE:
PROJECT No:
SCALE SHEET No. REV.
QUALITY RECORD :
APPROVED
NBNCO APPROVAL RECORD:
DD
AB
WD
REV DATE DESCRIPTION
SIGNATURE DATE
NBNCO DISCLAIMER
CADREF No:
NN KEY PLAN
OF
STRICTLY CONFIDENTIAL
THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE USE OFNBNCO LIMITED (ABN 86 136 533 741) FOR USE IN MAINTAININGNBNCO FACILITIES. IT HAS NOT BEEN CREATED FOR ANY OTHERUSE. IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS. NOWARRANTY IS GIVEN THAT THE INFORMATION IS ACCURATE ORCOMPLETE.
ENABLE#:
J&P RICHARDSONINDUSTRIES
NBN Co. PIT & PIPE INFRASTRUCTURETO PROPOSED SUBDIVISIONCASH STREET STAGE 1D'AGUILAR
QLD
STG-W000123258
E20-P.0302698.D.01
1:500 @ A1 3 3 -
- 25-05-20 M.L./B.H. ORIGINAL ISSUE
SOURCE DOCUMENTSDRG. No.AUTHOR REV. No. DATEM2584E-BASE - STANDARD.ZIP-----
JFP-----
------
28-04-20-----
SOURCE DOCUMENTSDRG. No.AUTHOR REV. No. DATE
-
STAGE 1 STAGE 2
STAGE 3STAGE 4
STAGE 5
CASH ST
AKOO
NAH
WY
FLINDERS ST
FLIND
ERS
ST
BRAD
MAN
ST
BRADMAN ST
14
15
16
17
18
19
20
21
22
23
24
25
26
27
PWR
3
6
5
P35
P35
P100P10
0
P50
P100
PIT-0
106
PIT-0116
PIT-0
125
PIT-0136
PIT-0145
PIT-0152
PIT-0
165
PIT-0
175
PIT-0
182
PIT-0
195
PIT-0205
154.1 P100
44.8 P100 14.2
P100
50.4
P100
43
P10024.9
P50
19
P100
40.7
P100
29
P50
19.8
P100
29
P100
50.7
P2014
P2014
P202
P202
P202 P20
2
P202
P202
P2015
P202
P202
P202
P202
P202
P202
P202
P202 P20
2
SDU Development InformationDevelopment Name:
Developer Company:
Authorised Rep:
Development Address:
nbn Reference Number: Stage Number:
Phone:E-Mail:
Design Revision:-
CASH ST D'AGUILAR
[email protected] 3271 2911
1STG-W000123258
MITCHELL LE GRANGE
CASH ST D'AGUILAR
DENNIS FAMILY CORPORATION
BILL OF MATERIAL
PITSSIZE25
89
QTYDUCTS
SIZE QTY MTRSP100P50P20
TOTAL NUMBER OF PITS:
TOTAL NUMBER OF CONDUITS:TOTAL LENGTH OF CONDUITS:
NO OF LOTS:
TOTAL NUMBER OF MANHOLES:
6
412400
18 795.54 76.627 79
20049951.1
27