dani instruments a scent of future - strumelab.com · dani instruments a scent of future...
TRANSCRIPT
DANI Instrumentsa scent of future
International Sales & Service Meeting 2007
Automatic samplerAS
is an automatic sampler to inject liquid samples in DANI
Automatic sampler
AS
GC
Sample trays and syringe needles are
positioned away from all heated surfaces. This configuration prevents volatile
solvent evaporation and degradation of thermally sensitive
samples.
MASTER AS – Sample Integrity
Why an Automatic Sampler?
The automatic sampler assures:
– identical movements– constant amount of solvent, air, internal
standard and sample into the syringe– constant speed of the plunger and time
intervals
MASTER AS – Why an Automatic Sampler
It offers repeatability and accuracy not available by manual injection.By manual injection, RSD% is never lower than 3%, ever with cold injection.
C12 C16 C20 C24 C26 C32 C36 C40
0
0,5
1
1,5
2
2,5
3
3,5
4
automatic sampling manual sampling
MASTER AS – Why an Automatic Sampler
Providing innovative sampling solutions, the DANI AS maximizes
laboratory productivity, mixing robotic technology with advanced three-dimensional
space movements (X-Y-Z)
MASTER AS – Innovation
3D Space Movements
Y
X Z
MASTER AS – 3D Space Movements
AS provides unprecedented automation and greater flexibility in sample capacity.
It provides maximum sample throughput with a standard 160 sample tray for 2mL vials or 65 sample tray for 10mL vials.
Sample Vial Tray
MASTER AS – Sample Vial Trey
Syringe
It is possible to use syringes of several volumes5, 10, 25, 50, 100, 250, 500 μL
5, 10, 25, 50, 100, 250, 500 µlSyringe sizes accepted
5Waste vials
5Solvent vials
65Sample capacity (10 ml vials)
160Sample capacity (2 ml vials)
MASTER AS – Syringe
The sample volumes, from 0.1 to 500 µl, are measured with great accuracy and precision.
This guarantees repeatability and linearity of the quantitative data.
MASTER AS - Precision
487,8698,8548,759,5max volume μL
5001005010syringe type μL
Linearity of Syringes
y = 0,9762xR2 = 0,9999
0
100
200
300
400
500
600
0 100 200 300 400 500 600
ul
mg
Gravimetric Test
MASTER AS - Repeatability
Average of 8 samplings of 1 µL for each syringe
Syringe Volume (µL) Weight (g) RSD%
10 1.007 0,173
25 0.887 0,157
50 0.893 0,158
100 0.905 0,157
250 0.862 0,199
500 0.970 0,153
Chromatographic TestC8 C10 C12 C14
1 188,749 157,419 102,825 101,7232 188,317 156,319 102,568 101,5773 187,259 155,916 101,847 101,074 187,479 156,438 101,89 101,6445 188,231 156,458 102,241 102,0046 188,108 156,314 102,214 101,8287 188,109 156,861 102,165 101,9568 188,024 156,89 101,859 101,1969 188,73 156,865 102,498 101,875
10 188,891 156,833 102,431 101,77111 188,518 157,469 102,749 101,401
Media (mV.s) 188,220 156,707 102,299 101,640SD 0,512 0,474 0,347 0,305
RSD% 0,272 0,303 0,339 0,300
y = 0,9733xR2 = 0,9999
0
100
200
300
400
500
600
0 100 200 300 400 500 600
ul
mg
Linearity of 500μL Syringe
MASTER AS - Linearity
Configuration
MASTER AS – Configuration
Software
Touch Screen
MASTER AS – Setup
Vial
&
Syringe
4 parameters• Solvent plug• Internal standard• Sample• Air plug
Injection Mode
MASTER AS – Parameters
With solvent plug it is not possible to rinse with sample and to set a number for plunger strokes
MASTER AS – Injection Mode
Solvent Plug
This parameter is an innovation of master AS compared with old ALS 1000
MASTER AS – Injection Mode
Internal Standard
Sample Handling
MASTER AS – Parameters
It is possible to set up to five solvents and I.S. with five wastes, to eliminate the possibility of sample carry over
MASTER AS – Setup
Solvent&Waste
All, any or a combination of pre and post solvent washes can be programmed during method setup
SolventWash
MASTER AS – Parameters
Injector
Up to three injectors can be selected for each method
MASTER AS – Parameters
You can set up to25 sequences of methods
MASTER AS – Sequence
Sample Sequence
The possibility during a analysisof setting up a sequence that startsimmediately after the end of thecurrent run
MASTER AS – Sequence
Priority Sequence
Software Setup
MASTER AS – Setup
Software Setup
MASTER AS – Parameters
Technical Specifications
YESFlush&Dry Sampling Mode
25 times/25 secSolvent post-injection washings
25 times/25 secSample pre-injection washings
CustomisableSampling Mode
YESVariable Sampling Depth
up to 100Injection per Vial
5, 10, 25, 50, 100, 250, 500 µlSyringe sizes
500 µlMaximum Sample Injection
0.1 µlMinimum Sample Injection
5 / 5Solvent / Waste Vials
65Sample Capacity (10ml vials)
160Sample Capacity (2ml vials)
X-Y-Z RobotSystem Type
MASTER AS - Specifications
YESVariable Injection Speed
YESInternal Standard Addition
YESPriority Sequence
3Injection Positions
RSD% < 0.5% (C12-C40)Repeatability
Touch Screen on MASTER GC Clarity Software
Instrument Control
YESExternal Software Control
RS-232Data Communications
455x750x650 mmDimensions (WxHxD)
13KgWeight
85-264Vac 50-60 HzPower Supply
MASTER AS - Specifications
MASTER AS - Consumables
What do you need for your
AS ?
MASTER AS - Consumables
Vials VIALS for Liquid Autosamplers Description Set of Code Vial 12x32 mm - volume 100 µl Vial 12x32 mm - volume 100 µl
50 pieces 50 pezzi
1262.011 004 Sample
MASTER AS - ALS1000 - HT300A - HT310A
Vial 12x32 mm - volume 1,5 ml Vial 12x32 mm - volume 1,5 ml
50 pieces 50 pezzi
1262.095 002 Sample
MASTER AS - ALS1000 - HT300A - HT310A
Vial 23x50 mm - volume 10.5 ml - screw top + cap + septa TFE/SIL Vial 23x50 mm - volume 10.5 ml - chiusura a vite completo di tappo e setto TFE/SIL
5 pieces 5 pezzi
1262.017 001 Solvent
MASTER AS - ALS1000
Vial 23x50 mm - volume 10.5 ml - screw top + cap + septa TFE/SIL Vial 23x50 mm - volume 10.5 ml - chiusura a vite completo di tappo e setto TFE/SIL
5 pieces 5 pezzi
1262.017 001 Waste
MASTER AS
Septa and Crimps
Septa and Crimp for Liquid Autosamplers Description Set of Code Crimp seal for Vial 12x32 mm Capsula per Vial 12x32 mm
100 pieces 100 pezzi
1260.895 001 MASTER AS - ALS1000 - HT300A - HT310A
Septa TFE/BUT for Crimp seal Setto TFE/BUT per Capsula
100 pieces 100 pezzi
1260.995 004 MASTER AS - ALS1000 - HT300A - HT310A
Septa TFE/SIL for Crimp seal Setto TFE/SIL per Capsula
100 pieces 100 pezzi
1260.905 004 MASTER AS - ALS1000 - HT300A - HT310A
Hand crimper for Crimp seal Pinza Chiudi Vials per Capsula
1 piece 1 pezzo
1343.000 006 MASTER AS - ALS1000 - HT300A - HT310A
1343.000 006
1260.995 004
1260.895 001
MASTER AS - Consumables
Syringes
MASTER AS - Consumables
SYRINGES for Liquid Autosamplers
Description Set of Code Microsyringe 5 ul Microsiringa 5 ul
1 piece 1 pezzo
1250.400 003 MASTER AS
Microsyringe 10 ul Microsiringa 10 ul
1 piece 1 pezzo
1250.401 002 MASTER AS - ALS1000
Microsyringe 25 ul Microsiringa 25 ul
1 piece 1 pezzo
1250.400 004 MASTER AS - HT300A - HT310A
Microsyringe 50 ul Microsiringa 50 ul
1 piece 1 pezzo
1250.400 005 MASTER AS - HT300A - HT310A
Microsyringe 100 ul Microsiringa 100 ul
1 piece 1 pezzo
1250.400 006 MASTER AS - HT300A - HT310A
Microsyringe 250 ul Microsiringa 250 ul
1 piece 1 pezzo
1250.400 007 MASTER AS
Microsyringe 500 ul Microsiringa 500 ul
1 piece 1 pezzo
1250.400 008 MASTER AS
Conclusions
Combined with
MASTER AS – Conclusions
GCit offers a complete system,
versatyle and reliable for every injection type.