dantura_3d
DESCRIPTION
Dantura_3DTRANSCRIPT
Dantura model pastic / Plastic Teeth 1/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
[mm]
-0.020
-0.016
-0.012
-0.008
-0.004
0.000
0.004
0.008
0.012
0.016
0.020
+0.01
-0.02
+0.00
+0.00
+0.02
Dimension 1Nominal Actual Dev Check
lZ +25.00 +24.82 -0.18
Dantura model pastic / Plastic Teeth 2/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
3D Mesh Quality 3/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
Dantura model pastic / Plastic Teeth 4/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
[mm] -70-65-60-55-50-45-40-35-30-25-20-15-10-5051015202530354045505560
-5
0
5
10
15
20
25
30
35
40
45
50
55
CAD model - Geomagic reverse engineering 5/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
CAD model - Geomagic reverse engineering 6/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
[mm] -70-65-60-55-50-45-40-35-30-25-20-15-10-5051015202530354045505560
-5
0
5
10
15
20
25
30
35
40
45
50
55
Control 3D - CAD model - Geomagic reverse engineering 7/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
[mm]
-0.020
-0.016
-0.012
-0.008
-0.004
0.000
0.004
0.008
0.012
0.016
0.020
+0.00
-0.02
+0.02
+0.01
+0.01
+0.00
Control 3D - CAD model - Geomagic reverse engineering 8/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
[mm]
-0.020
-0.016
-0.012
-0.008
-0.004
0.000
0.004
0.008
0.012
0.016
0.020
-0.02
+0.00
+0.00
+0.01
+0.02
+0.01
sectiuni prin modelul scanat 9/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
sectiuni prin modelul scanat 10/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
Control dimensiuni Dimensiuni 11/11
Inspector: Romeo TudoseCompany: Facultatea de Medicina DentaraDepartment: ImplantologieLocation: BucurestiDate: 6/30/11
Project: Reverse EngineeringPart:Part no.: Dummy Plastic Teeth Version: v1Charge no.:
System: ATOS IIeAlignment: Aligned 1
Generated with GOM Inspect V7 SR2
Length unit: mm
Dimension 1Nominal Actual Dev Check
lZ +25.00 +24.82 -0.18