(Split system, air to air heat pump type) DUCT CONNECTED-LOW/MIDDLE STATIC PRESSURE TYPE Single type FDUM100VNAWVH 100VSAWVH 125VNAWVH 125VSAWVH 140VNAWVH 140VSAWVH Twin type FDUM100VNAWPVH 100VSAWPVH 125VNAWPVH 125VSAWPVH 140VNAWPVH 140VSAWPVH Triple type FDUM140VNAWTVH 140VSAWTVH CEILING CASSETTE-4 WAY COMPACT TYPE Twin type FDTC100VNAWPVH 100VSAWPVH 125VNAWPVH 125VSAWPVH Single type FDT100VNAWVH 100VSAWVH 125VNAWVH 125VSAWVH 140VNAWVH 140VSAWVH CEILING CASSETTE-4 WAY TYPE Twin type FDT100VNAWPVH 100VSAWPVH 125VNAWPVH 125VSAWPVH 140VNAWPVH 140VSAWPVH Triple type FDT140VNAWTVH 140VSAWTVH Triple type FDTC140VNAWTVH 140VSAWTVH MICRO INVERTER PACKAGED AIR-CONDITIONERS Single type SRK100VNAWZR 100VSAWZR WALL MOUNTED TYPE Twin type SRK100VNAWPZSX 100VSAWPZSX 125VNAWPZSX 125VSAWPZSX 140VNAWPZR 140VSAWPZR Triple type SRK140VNAWTZSX 140VSAWTZSX DUCT CONNECTED-HIGH STATIC PRESSURE TYPE Single type FDU100VNAWVH 100VSAWVH 125VNAWVH 125VSAWVH 140VNAWVH 140VSAWVH (OUTDOOR UNIT) FDC100VNA-W 100VSA-W 125VNA-W 125VSA-W 140VNA-W 140VSA-W (INDOOR UNIT) FDT50VH 60VH 71VH FDE50VH 60VH 71VH V Multi System Single type FDE100VNAWVH 100VSAWVH 125VNAWVH 125VSAWVH 140VNAVWH 140VSAVWH Twin type FDE100VNAWPVH 100VSAWPVH 125VNAWPVH 125VSAWPVH 140VNAWPVH 140VSAWPVH CEILING SUSPENDED TYPE Triple type FDE140VNAWTVH 140VSAWTVH Manual No.'19 • PAC-DB-308D DATA BOOK DRAFT

Upload: others

Post on 24-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

(Split system, air to air heat pump type)

DUCT CONNECTED-LOW/MIDDLE STATIC PRESSURE TYPESingle type

FDUM100VNAWVH100VSAWVH125VNAWVH125VSAWVH140VNAWVH140VSAWVH

Twin type FDUM100VNAWPVH

100VSAWPVH125VNAWPVH125VSAWPVH140VNAWPVH140VSAWPVH

Triple type FDUM140VNAWTVH

140VSAWTVH

CEILING CASSETTE-4 WAY COMPACT TYPETwin type FDTC100VNAWPVH

100VSAWPVH125VNAWPVH125VSAWPVH

Single type FDT100VNAWVH

100VSAWVH125VNAWVH125VSAWVH140VNAWVH140VSAWVH

CEILING CASSETTE-4 WAY TYPETwin type FDT100VNAWPVH

100VSAWPVH125VNAWPVH125VSAWPVH140VNAWPVH140VSAWPVH

Triple type FDT140VNAWTVH

140VSAWTVH

Triple type FDTC140VNAWTVH

140VSAWTVH

MICRO INVERTER PACKAGED AIR-CONDITIONERS

Single type SRK100VNAWZR

100VSAWZR

WALL MOUNTED TYPETwin type

SRK100VNAWPZSX100VSAWPZSX125VNAWPZSX125VSAWPZSX140VNAWPZR140VSAWPZR

Triple typeSRK140VNAWTZSX

140VSAWTZSX

DUCT CONNECTED-HIGH STATIC PRESSURE TYPESingle type

FDU100VNAWVH100VSAWVH125VNAWVH125VSAWVH140VNAWVH140VSAWVH

(OUTDOOR UNIT)FDC100VNA-W

100VSA-W125VNA-W125VSA-W140VNA-W140VSA-W

(INDOOR UNIT)FDT50VH

60VH71VH

FDE50VH60VH71VH

V Multi System

Single type FDE100VNAWVH

100VSAWVH125VNAWVH125VSAWVH140VNAVWH140VSAVWH

Twin type FDE100VNAWPVH

100VSAWPVH125VNAWPVH125VSAWPVH140VNAWPVH140VSAWPVH

CEILING SUSPENDED TYPETriple type FDE140VNAWTVH

140VSAWTVH

Manual No.'19 • PAC-DB-308D

DATA BOOK

DRAFT

Page 2: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 1 -

TABLE OF CONTENTS

1. MICRO INVERTER PACKAGED AIR-CONDITIONERS ................................................. 22. V MULTI SYSTEM ...........................................................................................................208

Page 3: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 2 -

CONTENTS1.1 SPECIFICATIONS ........................................................................................ 3

(1) Ceiling cassette-4 way type (FDT) .......................................................... 3

(5) Ceiling suspended type (FDE) ................................................................ 43(6) Wall mounted type (SRK) ......................................................................... 57

(7) Wall mounted type (SRK) ............................................................................165

(3) Duct connected-High static pressure type (FDU) .................................... 23

1.2 EXTERIOR DIMENSIONS ............................................................................ 67(1) Indoor units .............................................................................................. 67(2) Outdoor units ........................................................................................... 79

1.4 NOISE LEVEL1.5 CHARACTERISTICS OF FAN

1.7 PIPING SYSTEM1.6 TEMPERATURE AND VELOCITY DISTRIBUTION

1.3 ELECTRICAL WIRING ................................................................................. 83

1.8 RANGE OF USAGE & LIMITATIONS

(1) Indoor units .............................................................................................. 83(2) Outdoor units ........................................................................................... 92

(3) Remote control (Option parts) .................................................................. 80

1.9 SELECTION CHART1.9.1 Capacity tables

1.9.2 Correction of cooling and heating capacity in relation to air flow rate control (fan speed)

(2) Ceiling cassette-4 way compact type (FDTC) ......................................... 17

(4) Duct connected-Low/Middle static pressure type (FDUM) ...................... 29

(1) Ceiling cassette-4 way type (FDT) ..............................................................134

(3) Ceiling suspended type (FDE) ....................................................................144

(6) Floor standing type (FDF) ...........................................................................161

(4) Duct connected-High static pressure type (FDU) ........................................151

(2) Ceiling cassette-4 way compact type (FDTC) .............................................141

(5) Duct connected-Low/Middle static pressure type (FDUM) ..........................154

1.9.3 Correction of cooling and heating capacity in relation to one way length of refrigerant piping1.9.4 Height difference between the indoor unit and outdoor unit

1.10 APPLICATION DATA1.10.1 Installation of indoor unit .....................................................................171

...................................................................................171

........................................................................................134

(1) Ceiling cassette-4 way type (FDT) ..............................................................171

(3) Ceiling suspended type (FDE) ....................................................................184(4) Duct connected-High static pressure type (FDU) ........................................188

(2) Ceiling cassette-4 way compact type (FDTC) .............................................178

..........170.....170

..............170

.................................................................................................108........................................................................113

........................................119.............................................................................................128

............................................................130.......................................................................................134

1. MICRO INVERTER PACKAGED AIR-CONDITIONERS

■How to read the model name

FDT : Ceiling cassette-4 way type

SRK : Wall mounted type

FDTC : Ceiling cassette-4 way compact typeFDU : Duct connected-High static pressure typeFDUM : Duct connected-Low/Middle static pressure type

Example: FDT 100 VNAW P VH

Series code

P : Twin type

: Single type

T : Triple typeApplicable power source...See the specificationProduct capacityModel name

FDC : Outdoor unit

(blank)

..........................................................................336(1) List of troubles ...........................................................................................336(2) Troubleshooting ........................................................................................338

1.12.2 Troubleshooting flow

(1) Selfdiagnosis function ...............................................................................301(2) Troubleshooting procedure .......................................................................306(3) Troubleshooting at the indoor unit .............................................................306(4) Troubleshooting at the outdoor unit ..........................................................321(5) Check of anomalous operation data with the remote control ....................331(6) Inverter checker for diagnosis of inverter output ......................................333(7) Outdoor unit control failure diagnosis circuit diagram ...............................334

1.12 MAINTENANCE DATA ...............................................................................3011.12.1 Diagnosing of microcomputer circuit ...............................................301

1.4 TECHNICAL INFORMATION ....................................................................... 94(1) Ceiling cassette-4 way type (FDT) .......................................................... 94

(5) Ceiling suspended type (FDE) ................................................................166(6) Wall mounted type (SRK) .......................................................................191

(3) Duct connected-High static pressure type (FDU) ...................................130(2) Ceiling cassette-4 way compact type (FDTC) .........................................119

1.13 DISASSEMBLY PROCEDURE ...................................................................418(1) Indoor unit ...............................................................................................418(2) Outdoor unit .............................................................................................432

(4) Duct connected-Low/Middle static pressure type (FDUM) .....................141

FDE : Ceiling suspended type

Page 4: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

FDT100VNAWVHIndoor unit FDT100VH Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.73

Heating 2.54Max power consumption 6.40

Running currentCooling

A13.2 / 13.8

Heating 12.4 / 13.0Inrush current, max current 5, 24

Power factorCooling

%90

Heating 89EER Cooling 3.66COP Heating 4.41

Sound power levelCooling

dB(A)

6269

Heating 70

Sound pressure levelCooling P-Hi: 47 Hi: 39 Me: 36 Lo: 30 54Heating P-Hi: 47 Hi: 39 Me: 36 Lo: 29 55

Silent mode sound pressure level — 48 /44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 298 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 25 Panel 5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 140 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 37 Hi: 26 Me: 23 Lo: 1775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") Pipe φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

PJF000Z589 B

(1) Ceiling cassette-4 way type (FDT) (a) Single type

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

1.1 SPECIFICATIONS

- 3 -

Page 5: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT100VSAWVHIndoor unit FDT100VH Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.73

Heating 2.54Max power consumption 10.20

Running currentCooling

A4.2 / 4.4

Heating 3.9 / 4.1Inrush current, max current 5, 15

Power factorCooling

%94

Heating 93EER Cooling 3.66COP Heating 4.41

Sound power levelCooling

dB(A)

6269

Heating 70

Sound pressure levelCooling P-Hi: 47 Hi: 39 Me: 36 Lo: 30 54Heating P-Hi: 47 Hi: 39 Me: 36 Lo: 29 55

Silent mode sound pressure level — 48 /44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 298 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 25 Panel 5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 140 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 37 Hi: 26 Me: 23 Lo: 1775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") Pipe φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 4 -

Page 6: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

FDT125VNAWVHIndoor unit FDT125VH Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.05

Heating 3.59Max power consumption 6.40

Running currentCooling

A18.7 / 19.6

Heating 16.8 / 17.5Inrush current, max current 5, 24

Power factorCooling

%94

Heating 93EER Cooling 3.09COP Heating 3.90

Sound power levelCooling

dB(A)

6371

Heating 64

Sound pressure levelCooling P-Hi: 48 Hi: 41 Me: 39 Lo: 31 54Heating P-Hi: 48 Hi: 41 Me: 38 Lo: 31 56

Silent mode sound pressure level — 48 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 298 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 25 Panel 5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 140 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 38 Hi: 28 Me: 25 Lo: 1875

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") Pipe φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PJF000Z589 B

- 5 -

Page 7: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT125VSAWVHIndoor unit FDT125VH Outdoor unit FDC125VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.05

Heating 3.59Max power consumption 10.20

Running currentCooling

A6.2 / 6.5

Heating 5.5 / 5.7Inrush current, max current 5, 15

Power factorCooling

%94

Heating 95EER Cooling 3.09COP Heating 3.90

Sound power levelCooling

dB(A)

6371

Heating 64

Sound pressure levelCooling P-Hi: 48 Hi: 41 Me: 39 Lo: 31 54Heating P-Hi: 48 Hi: 41 Me: 38 Lo: 31 56

Silent mode sound pressure level — 48 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 298 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 25 Panel 5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 140 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 38 Hi: 28 Me: 25 Lo: 1875

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") Pipe φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 6 -

Page 8: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

FDT140VNAWVHIndoor unit FDT140VH Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.79

Heating 4.18Max power consumption 6.40

Running currentCooling

A21.5 / 22.4

Heating 18.5 / 19.4Inrush current, max current 5, 24

Power factorCooling

%97

Heating 98EER Cooling 2.84COP Heating 3.71

Sound power levelCooling

dB(A)

63 72Heating 64 73

Sound pressure levelCooling P-Hi: 48 Hi: 42 Me: 39 Lo: 32 56Heating P-Hi: 48 Hi: 41 Me: 38 Lo: 31 58

Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 298 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 25 Panel 5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 140 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 38 Hi: 29 Me: 26 Lo: 1975

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") Pipe φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

PJF000Z589 B

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 7 -

Page 9: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT140VSAWVHIndoor unit FDT140VH Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.79

Heating 4.18Max power consumption 10.20

Running currentCooling

A7.4 / 7.7

Heating 6.6 / 7.0Inrush current, max current 5, 15

Power factorCooling

%94

Heating 91EER Cooling 2.84COP Heating 3.71

Sound power levelCooling

dB(A)

63 72Heating 64 73

Sound pressure levelCooling P-Hi: 48 Hi: 42 Me: 39 Lo: 32 56Heating P-Hi: 48 Hi: 41 Me: 38 Lo: 31 58

Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 298 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 25 Panel 5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 140 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 38 Hi: 29 Me: 26 Lo: 1975

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 8 -

Page 10: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

(b) Twin type

ModelItem

FDT100VNAWPVHIndoor unit FDT50VH (2 units) Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.82

Heating 2.73Max power consumption 6.40

Running currentCooling

A12.4 / 12.9

Heating 12.0 / 12.5Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.55COP Heating 4.11

Sound power levelCooling

dB(A)

55 69Heating 56 70

Sound pressure levelCooling P-Hi: 41 Hi: 33 Me: 30 Lo: 26 54Heating P-Hi: 42 Hi: 33 Me: 28 Lo: 20 55

Silent mode sound pressure level — 48 /44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 236 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 19 Panel 5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre - charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 22 Hi: 16 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 9 -

Page 11: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT100VSAWPVHIndoor unit FDT50VH (2 units) Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.82

Heating 2.73Max power consumption 10.20

Running currentCooling

A4.1 / 4.3

Heating 4.0 / 4.2Inrush current, max current 5, 15

Power factorCooling

%99

Heating 98EER Cooling 3.55COP Heating 4.11

Sound power levelCooling

dB(A)

55 69Heating 56 70

Sound pressure levelCooling P-Hi: 41 Hi: 33 Me: 30 Lo: 26 54Heating P-Hi: 42 Hi: 33 Me: 28 Lo: 20 55

Silent mode sound pressure level — 48 /44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 236 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 19 Panel 5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre - charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 22 Hi: 16 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 10 -

Page 12: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT125VNAWPVHIndoor unit FDT60VH (2 units) Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW3.79

Heating 3.31Max power consumption 6.40

Running currentCooling

A16.6 / 17.4

Heating 14.5 / 15.2Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.30COP Heating 4.23

Sound power levelCooling

dB(A)

5871

Heating 59

Sound pressure levelCooling P-Hi: 44 Hi: 34 Me: 30 Lo: 27 54Heating P-Hi: 44 Hi: 34 Me: 30 Lo: 20 56

Silent mode sound pressure level — 48 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 236 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 21 Panel 5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre - charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 26 Hi: 17 Me: 14 Lo: 1175

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 11 -

Page 13: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT125VSAWPVHIndoor unit FDT60VH (2 units) Outdoor unit FDC125VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW3.79

Heating 3.31Max power consumption 10.20

Running currentCooling

A5.5 / 5.8

Heating 4.8 / 5.1Inrush current, max current 5, 15

Power factorCooling

%99

Heating 99EER Cooling 3.30COP Heating 4.23

Sound power levelCooling

dB(A)

5871

Heating 59

Sound pressure levelCooling P-Hi: 44 Hi: 34 Me: 30 Lo: 27 54Heating P-Hi: 44 Hi: 34 Me: 30 Lo: 20 56

Silent mode sound pressure level — 48 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 236 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 21 Panel 5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre - charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 26 Hi: 17 Me: 14 Lo: 1175

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 12 -

Page 14: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT140VNAWPVHIndoor unit FDT71VH (2 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.22

Heating 3.57Max power consumption 6.40

Running currentCooling

A18.5 / 19.4

Heating 15.7 / 16.4Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.22COP Heating 4.34

Sound power levelCooling

dB(A)

59 72Heating 60 73

Sound pressure levelCooling

P-Hi: 46 Hi: 34 Me: 31 Lo: 2656

Heating 58Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 236 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 21 Panel 5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre - charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 28 Hi: 18 Me: 15 Lo: 1275

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") ②φ15.88(5/8")x1.0 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 13 -

Page 15: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT140VSAWPVHIndoor unit FDT71VH (2 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.22

Heating 3.57Max power consumption 10.20

Running currentCooling

A6.2 / 6.5

Heating 5.2 / 5.5Inrush current, max current 5, 15

Power factorCooling

%99

Heating 99EER Cooling 3.22COP Heating 4.34

Sound power levelCooling

dB(A)

59 72Heating 60 73

Sound pressure levelCooling

P-Hi: 46 Hi: 34 Me: 31 Lo: 2656

Heating 58Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 236 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 21 Panel 5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre - charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 28 Hi: 18 Me: 15 Lo: 1275

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") ②φ15.88(5/8")x1.0 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 14 -

Page 16: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT140VNAWTVHIndoor unit FDT50VH (3 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.22

Heating 3.57Max power consumption 6.40

Running currentCooling

A18.5 / 19.4

Heating 15.7 / 16.4Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.22COP Heating 3.88

Sound power levelCooling

dB(A)

55 72Heating 56 73

Sound pressure levelCooling P-Hi: 41 Hi: 33 Me: 30 Lo: 26 56Heating P-Hi: 42 Hi: 33 Me: 28 Lo: 20 58

Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 236 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 19 Panel 5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre - charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 22 Hi: 16 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.

(c) Triple type

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is three indoor units are combined and run together.(7) Branching pipe set "DIS-TB1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 15 -

Page 17: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT140VSAWTVHIndoor unit FDT50VH (3 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.22

Heating 3.57Max power consumption 10.20

Running currentCooling

A6.2 / 6.5

Heating 5.2 / 5.5Inrush current, max current 5, 15

Power factorCooling

%99

Heating 99EER Cooling 3.22COP Heating 3.88

Sound power levelCooling

dB(A)

55 72Heating 56 73

Sound pressure levelCooling P-Hi: 41 Hi: 33 Me: 30 Lo: 26 56Heating P-Hi: 42 Hi: 33 Me: 28 Lo: 20 58

Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 236 x 840 x 840Panel 35 x 950 x 950 845x970x370

Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 19 Panel 5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre - charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 22 Hi: 16 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-T-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is three indoor units are combined and run together.(7) Branching pipe set "DIS-TB1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 16 -

Page 18: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z517 B

ModelItem

FDTC100VNAWPVHIndoor unit FDTC50VH (2 units) Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW3.15

Heating 3.05Max power consumption 6.40

Running currentCooling

A13.8 / 14.5

Heating 13.4 / 14.0Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.17COP Heating 3.67

Sound power levelCooling

dB(A)

5969

Heating 70

Sound pressure levelCooling

P-Hi: 44 Hi 40 Me: 35 Lo: 2754

Heating 55Silent mode sound pressure level — 48 / 44 (Normal / Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 248 x 570 x 570Panel 10 x 620 x 620 845x970x370

Exterior appearance(Munsell color )(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9001) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 14 Panel 2.5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m )Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x 1Fan motor (Starting method) W 50 < Direct line start > 86 (Direct line start)

Air flow Cooling

m3/min P-Hi: 13 Hi: 11 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5, RCH-E3 Wireless : RCN-TC-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line I/U φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 O/Uφ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 ( Outdoor unit is higher ) / Max.15 ( Outdoor unit is lower ) Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts OA Spacer : TC-OAS-E2 , TC-OAD-E , Motion sensor : LB-TC-5W-E

The pipe length is 7.5m.

(2) Ceiling cassette-4 way compact type (FDTC) (a) Twin type

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 17 -

Page 19: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z517 B

ModelItem

FDTC100VSAWPVHIndoor unit FDTC50VH (2 units) Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW3.15

Heating 3.05Max power consumption 10.20

Running currentCooling

A4.6 / 4.9

Heating 4.4 / 4.7Inrush current, max current 5, 15

Power factorCooling

%98

Heating 99EER Cooling 3.17COP Heating 3.67

Sound power levelCooling

dB(A)

5969

Heating 70

Sound pressure levelCooling

P-Hi: 44 Hi 40 Me: 35 Lo: 2754

Heating 55Silent mode sound pressure level — 48 / 44 (Normal / Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 248 x 570 x 570Panel 10 x 620 x 620 845x970x370

Exterior appearance(Munsell color )(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9001) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 14 Panel 2.5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m )Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x 1Fan motor (Starting method) W 50 < Direct line start > 86 (Direct line start)

Air flow Cooling

m3/min P-Hi: 13 Hi: 11 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5, RCH-E3 Wireless : RCN-TC-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line I/U φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 O/Uφ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 ( Outdoor unit is higher ) / Max.15 ( Outdoor unit is lower ) Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts OA Spacer : TC-OAS-E2 , TC-OAD-E , Motion sensor : LB-TC-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 18 -

Page 20: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z517 B

ModelItem

FDTC125VNAWPVHIndoor unit FDTC60VH (2 units) Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.90

Heating 4.30Max power consumption 6.40

Running currentCooling

A21.5 / 22.5

Heating 18.9 / 19.7Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 2.55COP Heating 3.26

Sound power levelCooling

dB(A)

59 71Heating

Sound pressure levelCooling

P-Hi: 44 Hi 40 Me: 35 Lo: 2754

Heating 56Silent mode sound pressure level — 48 / 45 (Normal / Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 248 x 570 x 570Panel 10 x 620 x 620 845x970x370

Exterior appearance(Munsell color )(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9001) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 14 Panel 2.5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m )Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x 1Fan motor (Starting method) W 50 < Direct line start > 86 (Direct line start)

Air flow Cooling

m3/min P-Hi: 13 Hi: 11 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5, RCH-E3 Wireless : RCN-TC-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line I/U φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 O/Uφ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 ( Outdoor unit is higher ) / Max.15 ( Outdoor unit is lower ) Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts OA Spacer : TC-OAS-E2 , TC-OAD-E , Motion sensor : LB-TC-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 19 -

Page 21: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z517 B

ModelItem

FDTC125VSAWPVHIndoor unit FDTC60VH (2 units) Outdoor unit FDC125VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.90

Heating 4.30Max power consumption 10.20

Running currentCooling

A7.1 / 7.5

Heating 6.3 / 6.6Inrush current, max current 5, 15

Power factorCooling

%99

Heating 99EER Cooling 2.55COP Heating 3.26

Sound power levelCooling

dB(A)

59 71Heating

Sound pressure levelCooling

P-Hi: 44 Hi 40 Me: 35 Lo: 2754

Heating 56Silent mode sound pressure level — 48 / 45 (Normal / Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 248 x 570 x 570Panel 10 x 620 x 620 845x970x370

Exterior appearance(Munsell color )(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9001) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 14 Panel 2.5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m )Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x 1Fan motor (Starting method) W 50 < Direct line start > 86 (Direct line start)

Air flow Cooling

m3/min P-Hi: 13 Hi: 11 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5, RCH-E3 Wireless : RCN-TC-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line I/U φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 O/Uφ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 ( Outdoor unit is higher ) / Max.15 ( Outdoor unit is lower ) Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts OA Spacer : TC-OAS-E2 , TC-OAD-E , Motion sensor : LB-TC-5W-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 20 -

Page 22: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z517 B

ModelItem

FDTC140VNAWTVHIndoor unit FDTC50VH (3 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.75

Heating 4.60Max power consumption 6.40

Running currentCooling

A20.9 / 21.8

Heating 20.2 / 21.1Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 2.86COP Heating 3.37

Sound power levelCooling

dB(A)

5972

Heating 73

Sound pressure levelCooling

P-Hi: 44 Hi 40 Me: 35 Lo: 2756

Heating 58Silent mode sound pressure level — 49 / 45 (Normal / Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 248 x 570 x 570Panel 10 x 620 x 620 845x970x370

Exterior appearance(Munsell color )(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9001) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 14 Panel 2.5 77Compressor type & Q'ty — RMT5126SWP3 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m )Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x 1Fan motor (Starting method) W 50 < Direct line start > 86 (Direct line start)

Air flow Cooling

m3/min P-Hi: 13 Hi: 11 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5, RCH-E3 Wireless : RCN-TC-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line I/U φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 O/Uφ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 ( Outdoor unit is higher ) / Max.15 ( Outdoor unit is lower ) Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts OA Spacer : TC-OAS-E2 , TC-OAD-E , Motion sensor : LB-TC-5W-E

The pipe length is 7.5m.

(b) Triple type

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 21 -

Page 23: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z517 B

ModelItem

FDTC140VSAWTVHIndoor unit FDTC50VH (3 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.75

Heating 4.60Max power consumption 10.20

Running currentCooling

A6.9 / 7.3

Heating 6.7 / 7.1Inrush current, max current 5, 15

Power factorCooling

%99

Heating 99EER Cooling 2.86COP Heating 3.37

Sound power levelCooling

dB(A)

5972

Heating 73

Sound pressure levelCooling

P-Hi: 44 Hi 40 Me: 35 Lo: 2756

Heating 58Silent mode sound pressure level — 49 / 45 (Normal / Silent)

Exterior dimensions (Height x Width x Depth) mm Unit 248 x 570 x 570Panel 10 x 620 x 620 845x970x370

Exterior appearance(Munsell color )(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9001) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg Unit 14 Panel 2.5 78Compressor type & Q'ty — RMT5126SWP4 x 1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m )Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Turbo fan x1 Propeller fan x 1Fan motor (Starting method) W 50 < Direct line start > 86 (Direct line start)

Air flow Cooling

m3/min P-Hi: 13 Hi: 11 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x1(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5, RCH-E3 Wireless : RCN-TC-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line I/U φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 O/Uφ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 ( Outdoor unit is higher ) / Max.15 ( Outdoor unit is lower ) Drain hose Hose connectable with VP25(O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 850 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts OA Spacer : TC-OAS-E2 , TC-OAD-E , Motion sensor : LB-TC-5W-E

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U - Branch, ② : Pipe of Branch - I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 22 -

Page 24: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Notes (1) The data are measured at the following conditions.

PJG000Z625 A

ModelItem

FDU100VNAWVHIndoor unit FDU100VH Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.99

Heating 2.66Max power consumption 6.40

Running currentCooling

A14.3 / 14.9

Heating 12.7 / 13.3Inrush current, max current 5, 26

Power factorCooling

%91

Heating 91EER Cooling 3.35COP Heating 4.21

Sound power levelCooling

dB(A)

6569

Heating 70

Sound pressure levelCooling

P-Hi: 44 Hi: 38 Me: 36 Lo: 3054

Heating 55Silent mode sound pressure level — 48 / 44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 130 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 36 Hi: 28 Me: 25 Lo: 1975

Heating 73Available external static pressure Pa Standard: 60 Max: 200 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-KIT

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) When wireless remote control is used, fan is 3 speed setting (Hi-Me-Lo) only.(6) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(7) The factory E.S.P. setting is set within the range of 80 - 150 Pa.If SW8-4 is turned to "ON",

E.S.P. setting range can be changed to 10 - 200 Pa.(For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

(3) Duct connected-High static pressure type (FDU) Single type

The pipe length is 7.5m.

- 23 -

Page 25: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z625 A

ModelItem

FDU100VSAWVHIndoor unit FDU100VH Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.99

Heating 2.66Max power consumption 10.20

Running currentCooling

A4.6 / 4.9

Heating 4.1 / 4.3Inrush current, max current 5, 17

Power factorCooling

%93

Heating 93EER Cooling 3.35COP Heating 4.21

Sound power levelCooling

dB(A)

6569

Heating 70

Sound pressure levelCooling

P-Hi: 44 Hi: 38 Me: 36 Lo: 3054

Heating 55Silent mode sound pressure level — 48 / 44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 130 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 36 Hi: 28 Me: 25 Lo: 1975

Heating 73Available external static pressure Pa Standard: 60 Max: 200 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) When wireless remote control is used, fan is 3 speed setting (Hi-Me-Lo) only.(6) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(7) The factory E.S.P. setting is set within the range of 80 - 150 Pa.If SW8-4 is turned to "ON",

E.S.P. setting range can be changed to 10 - 200 Pa.(For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 24 -

Page 26: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z625 A

ModelItem

FDU125VNAWVHIndoor unit FDU125VH Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.36

Heating 3.69Max power consumption 6.40

Running currentCooling

A20.4 / 21.3

Heating 17.8 / 18.6Inrush current, max current 5, 26

Power factorCooling

%93

Heating 90EER Cooling 2.87COP Heating 3.79

Sound power levelCooling

dB(A)

67 71Heating

Sound pressure levelCooling

P-Hi: 45 Hi: 40 Me: 34 Lo: 2954

Heating 56Silent mode sound pressure level — 48 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 200 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 39 Hi: 32 Me: 26 Lo: 2075

Heating 73Available external static pressure Pa Standard: 60 Max: 200 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) When wireless remote control is used, fan is 3 speed setting (Hi-Me-Lo) only.(6) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(7) The factory E.S.P. setting is set within the range of 80 - 150 Pa.If SW8-4 is turned to "ON",

E.S.P. setting range can be changed to 10 - 200 Pa.(For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 25 -

Page 27: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z625 A

ModelItem

FDU125VSAWVHIndoor unit FDU125VH Outdoor unit FDC125VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.36

Heating 3.69Max power consumption 10.20

Running currentCooling

A6.8 / 7.2

Heating 5.9 / 6.2Inrush current, max current 5, 17

Power factorCooling

%92

Heating 90EER Cooling 2.87COP Heating 3.79

Sound power levelCooling

dB(A)

67 71Heating

Sound pressure levelCooling

P-Hi: 45 Hi: 40 Me: 34 Lo: 2954

Heating 56Silent mode sound pressure level — 48 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 200 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 39 Hi: 32 Me: 26 Lo: 2075

Heating 73Available external static pressure Pa Standard: 60 Max: 200 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) When wireless remote control is used, fan is 3 speed setting (Hi-Me-Lo) only.(6) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(7) The factory E.S.P. setting is set within the range of 80 - 150 Pa.If SW8-4 is turned to "ON",

E.S.P. setting range can be changed to 10 - 200 Pa.(For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 26 -

Page 28: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z625 A

ModelItem

FDU140VNAWVHIndoor unit FDU140VH Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.13

Heating 4.21Max power consumption 6.40

Running currentCooling

A23.7 / 24.8

Heating 20.3 / 21.3Inrush current, max current 5, 27

Power factorCooling

%94

Heating 90EER Cooling 2.65COP Heating 3.68

Sound power levelCooling

dB(A)

7072

Heating 73

Sound pressure levelCooling

P-Hi: 47 Hi: 40 Me: 35 Lo: 3056

Heating 58Silent mode sound pressure level — 49 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 200 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 48 Hi: 35 Me: 28 Lo: 2275

Heating 73Available external static pressure Pa Standard: 60 Max: 200 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) When wireless remote control is used, fan is 3 speed setting (Hi-Me-Lo) only.(6) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(7) The factory E.S.P. setting is set within the range of 80 - 150 Pa.If SW8-4 is turned to "ON",

E.S.P. setting range can be changed to 10 - 200 Pa.(For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 27 -

Page 29: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z625 A

ModelItem

FDU140VSAWVHIndoor unit FDU140VH Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.13

Heating 4.21Max power consumption 10.20

Running currentCooling

A8.1 / 8.6

Heating 6.8 / 7.2Inrush current, max current 5, 18

Power factorCooling

%91

Heating 89EER Cooling 2.65COP Heating 3.68

Sound power levelCooling

dB(A)

7072

Heating 73

Sound pressure levelCooling

P-Hi: 47 Hi: 40 Me: 35 Lo: 3056

Heating 58Silent mode sound pressure level — 49 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 200 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 48 Hi: 35 Me: 28 Lo: 2275

Heating 73Available external static pressure Pa Standard: 60 Max: 200 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare piping

Attached length of piping m — —

Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mmx 3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) When wireless remote control is used, fan is 3 speed setting (Hi-Me-Lo) only.(6) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(7) The factory E.S.P. setting is set within the range of 80 - 150 Pa.If SW8-4 is turned to "ON",

E.S.P. setting range can be changed to 10 - 200 Pa.(For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 28 -

Page 30: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM100VNAWVHIndoor unit FDUM100VH Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.99

Heating 2.66Max power consumption 6.40

Running currentCooling

A14.3 / 14.9

Heating 12.7 / 13.3Inrush current, max current 5, 26

Power factorCooling

%91

Heating 91EER Cooling 3.35COP Heating 4.21

Sound power levelCooling

dB(A)

6569

Heating 70

Sound pressure levelCooling

P-Hi: 44 Hi: 38 Me: 36 Lo: 3054

Heating 55Silent mode sound pressure level — 48 / 44 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 130 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 36 Hi: 28 Me: 25 Lo: 1975

Heating 73Available external static pressure Pa Standard: 60 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL3EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Static pressure of option air filter "UM-FL3EF" is 5Pa initially.(7) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

(4) Duct connected-Low / Middle static pressure type (FDUM)(a) Single type

The pipe length is 7.5m.

- 29 -

Page 31: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM100VSAWVHIndoor unit FDUM100VH Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.99

Heating 2.66Max power consumption 10.20

Running currentCooling

A4.6 / 4.9

Heating 4.1 / 4.3Inrush current, max current 5, 17

Power factorCooling

%93

Heating 93EER Cooling 3.35COP Heating 4.21

Sound power levelCooling

dB(A)

6569

Heating 70

Sound pressure levelCooling

P-Hi: 44 Hi: 38 Me: 36 Lo: 3054

Heating 55Silent mode sound pressure level — 48 / 44 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 130 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 36 Hi: 28 Me: 25 Lo: 1975

Heating 73Available external static pressure Pa Standard: 60 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL3EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Static pressure of option air filter "UM-FL3EF" is 5Pa initially.(7) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 30 -

Page 32: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM125VNAWVHIndoor unit FDUM125VH Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.36

Heating 3.69Max power consumption 6.40

Running currentCooling

A20.4 / 21.3

Heating 17.8 / 18.6Inrush current, max current 5, 26

Power factorCooling

%93

Heating 90EER Cooling 2.87COP Heating 3.79

Sound power levelCooling

dB(A)

67 71Heating

Sound pressure levelCooling

P-Hi: 45 Hi: 40 Me: 34 Lo: 2954

Heating 56Silent mode sound pressure level — 48 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 200 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 39 Hi: 32 Me: 26 Lo: 2075

Heating 73Available external static pressure Pa Standard: 60 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL3EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Static pressure of option air filter "UM-FL3EF" is 5Pa initially.(7) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 31 -

Page 33: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM125VSAWVHIndoor unit FDUM125VH Outdoor unit FDC125VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.36

Heating 3.69Max power consumption 10.20

Running currentCooling

A6.8 / 7.2

Heating 5.9 / 6.2Inrush current, max current 5, 17

Power factorCooling

%92

Heating 90EER Cooling 2.87COP Heating 3.79

Sound power levelCooling

dB(A)

67 71Heating

Sound pressure levelCooling

P-Hi: 45 Hi: 40 Me: 34 Lo: 2954

Heating 56Silent mode sound pressure level — 48 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 200 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 39 Hi: 32 Me: 26 Lo: 2075

Heating 73Available external static pressure Pa Standard: 60 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL3EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Static pressure of option air filter "UM-FL3EF" is 5Pa initially.(7) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 32 -

Page 34: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM140VNAWVHIndoor unit FDUM140VH Outdoor unit FDC140VNA-W

Power source 1 Phase, 220-240V - 50Hz / 220V - 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.13

Heating 4.21Max power consumption 6.40

Running currentCooling

A23.7 / 24.8

Heating 20.3 / 21.3Inrush current, max current 5, 27

Power factorCooling

%94

Heating 90EER Cooling 2.65COP Heating 3.68

Sound power levelCooling

dB(A)

7072

Heating 73

Sound pressure levelCooling

P-Hi: 47 Hi: 40 Me: 35 Lo: 3056

Heating 58Silent mode sound pressure level — 49 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 200 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 48 Hi: 35 Me: 28 Lo: 2275

Heating 73Available external static pressure Pa Standard: 60 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL3EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Static pressure of option air filter "UM-FL3EF" is 5Pa initially.(7) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 33 -

Page 35: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM140VSAWVHIndoor unit FDUM140VH Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.13

Heating 4.21Max power consumption 10.20

Running currentCooling

A8.1 / 8.6

Heating 6.8 / 7.2Inrush current, max current 5, 18

Power factorCooling

%91

Heating 89EER Cooling 2.65COP Heating 3.68

Sound power levelCooling

dB(A)

7072

Heating 73

Sound pressure levelCooling

P-Hi: 47 Hi: 40 Me: 35 Lo: 3056

Heating 58Silent mode sound pressure level — 49 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 1,370 × 740 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 54 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×3 Propeller fan ×1Fan motor (Starting method) W 100 + 200 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 48 Hi: 35 Me: 28 Lo: 2275

Heating 73Available external static pressure Pa Standard: 60 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipeφ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL3EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Static pressure of option air filter "UM-FL3EF" is 5Pa initially.(7) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

60PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 34 -

Page 36: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM100VNAWPVHIndoor unit FDUM50VH (2 units) Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW3.25

Heating 3.04Max power consumption 6.40

Running currentCooling

A14.6 / 15.2

Heating 13.6 / 14.2Inrush current, max current 5, 26

Power factorCooling

%97

Heating 97EER Cooling 3.08COP Heating 3.68

Sound power levelCooling

dB(A)

6069

Heating 70

Sound pressure levelCooling

P-Hi: 37 Hi: 32 Me: 29 Lo: 2654

Heating 55Silent mode sound pressure level — 48 / 44 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 750 × 635 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 29 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×1 Propeller fan ×1Fan motor (Starting method) W 100 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 13 Hi: 10 Me: 9 Lo: 875

Heating 73Available external static pressure Pa Standard: 35 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL1EF , Motion sensor : LB-KIT

(b) Twin type

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch,② : Pipe of Branch-I/U(8) Static pressure of option air filter "UM-FL1EF" is 5Pa initially.(9) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

35PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 35 -

Page 37: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM100VSAWPVHIndoor unit FDUM50VH (2 units) Outdoor unit FDC100VSA-W

Power source 3 Phase, 380-415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW3.25

Heating 3.04Max power consumption 10.20

Running currentCooling

A4.9 / 5.2

Heating 4.6 / 4.8Inrush current, max current 5, 17

Power factorCooling

%95

Heating 96EER Cooling 3.08COP Heating 3.68

Sound power levelCooling

dB(A)

6069

Heating 70

Sound pressure levelCooling

P-Hi: 37 Hi: 32 Me: 29 Lo: 2654

Heating 55Silent mode sound pressure level — 48 / 44 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 750 × 635 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 29 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×1 Propeller fan ×1Fan motor (Starting method) W 100 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 13 Hi: 10 Me: 9 Lo: 875

Heating 73Available external static pressure Pa Standard: 35 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL1EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch,② : Pipe of Branch-I/U(8) Static pressure of option air filter "UM-FL1EF" is 5Pa initially.(9) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

35PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 36 -

Page 38: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM125VNAWPVHIndoor unit FDUM60VH (2 units) Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.53

Heating 3.52Max power consumption 6.40

Running currentCooling

A20.3 / 21.2

Heating 15.8 / 16.5Inrush current, max current 5, 26

Power factorCooling

%97

Heating 97EER Cooling 2.76COP Heating 3.98

Sound power levelCooling

dB(A)

60 71Heating

Sound pressure levelCooling

P-Hi: 36 Hi: 31 Me: 28 Lo: 2554

Heating 56Silent mode sound pressure level — 48 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 950 × 635 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 34 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×2 Propeller fan ×1Fan motor (Starting method) W 130 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 20 Hi: 15 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa Standard: 35 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL2EF , Motion sensor : LB-KIT

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch,② : Pipe of Branch-I/U(8) Static pressure of option air filter "UM-FL2EF" is 5Pa initially.(9) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

35PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 37 -

Page 39: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM125VSAWPVHIndoor unit FDUM60VH (2 units) Outdoor unit FDC125VSA-W

Power source 3 Phase, 380-415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.53

Heating 3.52Max power consumption 10.20

Running currentCooling

A6.7 / 7.0

Heating 5.2 / 5.5Inrush current, max current 5, 17

Power factorCooling

%98

Heating 97EER Cooling 2.76COP Heating 3.98

Sound power levelCooling

dB(A)

60 71Heating

Sound pressure levelCooling

P-Hi: 36 Hi: 31 Me: 28 Lo: 2554

Heating 56Silent mode sound pressure level — 48 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 950 × 635 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 34 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×2 Propeller fan ×1Fan motor (Starting method) W 130 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 20 Hi: 15 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa Standard: 35 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL2EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch,② : Pipe of Branch-I/U(8) Static pressure of option air filter "UM-FL2EF" is 5Pa initially.(9) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

35PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 38 -

Page 40: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM140VNAWTVHIndoor unit FDUM71VH (2 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.02

Heating 4.20Max power consumption 6.40

Running currentCooling

A22.5 / 23.5

Heating 18.8 / 19.7Inrush current, max current 5, 27

Power factorCooling

%97

Heating 97EER Cooling 2.71COP Heating 3.69

Sound power levelCooling

dB(A)

6572

Heating 73

Sound pressure levelCooling

P-Hi: 38 Hi: 33 Me: 29 Lo: 2556

Heating 58Silent mode sound pressure level — 49 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 950 × 635 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 34 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×2 Propeller fan ×1Fan motor (Starting method) W 130 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 24 Hi: 19 Me: 15 Lo: 1075

Heating 73Available external static pressure Pa Standard: 35 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") ②φ15.88(5/8")x1.0 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL2EF , Motion sensor : LB-KIT

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch,② : Pipe of Branch-I/U(8) Static pressure of option air filter "UM-FL2EF" is 5Pa initially.(9) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

35PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 39 -

Page 41: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM140VSAWPVHIndoor unit FDUM71VH (2 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60H

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.02

Heating 4.20Max power consumption 10.20

Running currentCooling

A7.5 / 7.9

Heating 6.1 / 6.4Inrush current, max current 5, 18

Power factorCooling

%97

Heating 99EER Cooling 2.71COP Heating 3.69

Sound power levelCooling

dB(A)

6572

Heating 73

Sound pressure levelCooling

P-Hi: 38 Hi: 33 Me: 29 Lo: 2556

Heating 58Silent mode sound pressure level — 49 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 950 × 635 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 34 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×2 Propeller fan ×1Fan motor (Starting method) W 130 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 24 Hi: 19 Me: 15 Lo: 1075

Heating 73Available external static pressure Pa Standard: 35 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 15.88 (5/8") ②φ15.88(5/8")x1.0 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL2EF , Motion sensor : LB-KIT

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch,② : Pipe of Branch-I/U(8) Static pressure of option air filter "UM-FL2EF" is 5Pa initially.(9) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

35PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 40 -

Page 42: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM140VNAWTVHIndoor unit FDUM50VH (3 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.02

Heating 4.20Max power consumption 6.40

Running currentCooling

A22.5 / 23.5

Heating 18.8 / 19.7Inrush current, max current 5, 27

Power factorCooling

%97

Heating 97EER Cooling 2.71COP Heating 3.69

Sound power levelCooling

dB(A)

6072

Heating 73

Sound pressure levelCooling

P-Hi: 37 Hi: 32 Me: 29 Lo: 2656

Heating 58Silent mode sound pressure level — 49 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 750 × 635 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 29 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×1 Propeller fan ×1Fan motor (Starting method) W 100 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 13 Hi: 10 Me: 9 Lo: 875

Heating 73Available external static pressure Pa Standard: 35 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL1EF , Motion sensor : LB-KIT

(c) Triple type

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is three indoor units are combined and run together.(7) Branching pipe set "DIS-TA1G"×1(Option). ① : Pipe of O/U-Branch,② : Pipe of Branch-I/U(8) Static pressure of option air filter "UM-FL1EF" is 5Pa initially.(9) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

35PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 41 -

Page 43: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJG000Z491 B

ModelItem

FDUM140VSAWTVHIndoor unit FDUM50VH (3 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380-415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.02

Heating 4.20Max power consumption 10.20

Running currentCooling

A7.5 / 7.9

Heating 6.1 / 6.4Inrush current, max current 5, 18

Power factorCooling

%97

Heating 99EER Cooling 2.71COP Heating 3.69

Sound power levelCooling

dB(A)

6072

Heating 73

Sound pressure levelCooling

P-Hi: 37 Hi: 32 Me: 29 Lo: 2656

Heating 58Silent mode sound pressure level — 49 / 45 (Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 280 × 750 × 635 845 × 970 × 370Exterior appearance(Munsell color )(RAL color )

—Stucco white

(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 29 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 ( M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan ×1 Propeller fan ×1Fan motor (Starting method) W 100 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 13 Hi: 10 Me: 9 Lo: 875

Heating 73Available external static pressure Pa Standard: 35 Max: 100 0Outside air intake Possible —Air filter, Quality / Quantity Procure locally —Shock & vibration absorber Rubber sleeve (for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20 (Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A,RC-E5,RCH-E3 Wireless : RCN-KIT4-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35 (1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/Uφ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ12.7(1/2")x0.8 ①φ15.88(5/8")x1.0 φ15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable VP25 (I.D.25, O.D.32) Hole size φ 20 x 3pcs

Drain pump, max lift height mm Built-in drain pump , 600 —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ1.6mm×3 cores + earth cable / Terminal block (Screw fixing type)IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Filter set : UM-FL1EF , Motion sensor : LB-KIT

Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is three indoor units are combined and run together.(7) Branching pipe set "DIS-TA1G"×1(Option). ① : Pipe of O/U-Branch,② : Pipe of Branch-I/U(8) Static pressure of option air filter "UM-FL1EF" is 5Pa initially.(9) The external static pressure setting can be changed to 10-100Pa. (For RC-EX3A and RC-E5 only)

ItemOperation

Indoor air temperature Outdoor air temperature External static pressure of indoor unit Standards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C

35PaISO5151-T1

Heating 20˚C — 7˚C 6˚C ISO5151-H1

The pipe length is 7.5m.

- 42 -

Page 44: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE100VNAWVHIndoor unit FDE100VH Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.85

Heating 2.54Max power consumption 6.40

Running currentCooling

A13.8 / 14.4

Heating 12.4 / 13.0Inrush current, max current 5, 24

Power factorCooling

%90

Heating 89EER Cooling 3.51COP Heating 4.41

Sound power levelCooling

dB(A)

6469

Heating 70

Sound pressure levelCooling

P-Hi: 48 Hi: 43 Me: 38 Lo: 3454

Heating 55Silent mode sound pressure level — 48 /44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 250 x 1,620 x 690 845 x 970 x 370Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 43 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 80 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 32 Hi: 26 Me: 21 Lo: 16.575

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Connecting method

Liquid linemm

I/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")Gas line φ 15.88 (5/8") φ 15.88(5/8")x1.0 φ 15.88 (5/8")

Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

(5) Ceiling suspended type (FDE) (a) Single type

- 43 -

Page 45: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE100VSAWVHIndoor unit FDE100VH Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.85

Heating 2.54Max power consumption 10.20

Running currentCooling

A4.6 / 4.8

Heating 4.0 / 4.2Inrush current, max current 5, 15

Power factorCooling

%90

Heating 91EER Cooling 3.51COP Heating 4.41

Sound power levelCooling

dB(A)

6469

Heating 70

Sound pressure levelCooling

P-Hi: 48 Hi: 43 Me: 38 Lo: 3454

Heating 55Silent mode sound pressure level — 48 /44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 250 x 1,620 x 690 845 x 970 x 370Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 43 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 80 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 32 Hi: 26 Me: 21 Lo: 16.575

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Connecting method

Liquid linemm

I/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")Gas line φ 15.88 (5/8") φ 15.88(5/8")x1.0 φ 15.88 (5/8")

Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 44 -

Page 46: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE125VNAWVHIndoor unit FDE125VH Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.45

Heating 3.74Max power consumption 6.40

Running currentCooling

A20.4 / 21.3

Heating 17.5 / 18.3Inrush current, max current 5, 24

Power factorCooling

%95

Heating 93EER Cooling 2.81COP Heating 3.74

Sound power levelCooling

dB(A)

64 71Heating

Sound pressure levelCooling

P-Hi: 48 Hi: 45 Me: 40 Lo: 3554

Heating 56Silent mode sound pressure level — 48 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 250 x 1,620 x 690 845 x 970 x 370Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 43 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 80 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 32 Hi: 29 Me: 23 Lo: 1775

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Connecting method

Liquid linemm

I/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")Gas line φ 15.88 (5/8") φ 15.88(5/8")x1.0 φ 15.88 (5/8")

Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 45 -

Page 47: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE125VSAWVHIndoor unit FDE125VH Outdoor unit FDC125VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.45

Heating 3.74Max power consumption 10.20

Running currentCooling

A6.9 / 7.3

Heating 5.9 / 6.2Inrush current, max current 5, 15

Power factorCooling

%93

Heating 91EER Cooling 2.81COP Heating 3.74

Sound power levelCooling

dB(A)

64 71Heating

Sound pressure levelCooling

P-Hi: 48 Hi: 45 Me: 40 Lo: 3554

Heating 56Silent mode sound pressure level — 48 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 250 x 1,620 x 690 845 x 970 x 370Exterior appearance(Munsell color )(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 43 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 80 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 32 Hi: 29 Me: 23 Lo: 1775

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Connecting method

Liquid linemm

I/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")Gas line φ 15.88 (5/8") φ 15.88(5/8")x1.0 φ 15.88 (5/8")

Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 46 -

Page 48: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE140VNAWVHIndoor unit FDE140VH Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.05

Heating 4.18Max power consumption 6.40

Running currentCooling

A22.2 / 23.2

Heating 18.4 / 19.2Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 2.69COP Heating 3.71

Sound power levelCooling

dB(A)

6572

Heating 73

Sound pressure levelCooling

P-Hi: 49 Hi: 45 Me: 40 Lo: 3656

Heating 58Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 250 x 1,620 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 43 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 90 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 34 Hi: 29 Me: 23 Lo: 1875

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 47 -

Page 49: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

FDE140VSAWVHIndoor unit FDE140VH Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW5.05

Heating 4.18Max power consumption 10.20

Running currentCooling

A7.8 / 8.2

Heating 6.5 / 6.8Inrush current, max current 5, 15

Power factorCooling

%94

Heating 93EER Cooling 2.69COP Heating 3.71

Sound power levelCooling

dB(A)

6572

Heating 73

Sound pressure levelCooling

P-Hi: 49 Hi: 45 Me: 40 Lo: 3656

Heating 58Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 250 x 1,620 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 43 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing Straight fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 90 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 34 Hi: 29 Me: 23 Lo: 1875

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PFA004Z088 B

- 48 -

Page 50: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE100VNAWPVHIndoor unit FDE50VH (2 units) Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.3(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW3.12

Heating 2.99Max power consumption 6.40

Running currentCooling

A14.0 / 14.6

Heating 13.4 / 14.0Inrush current, max current 5, 24

Power factorCooling

%97

Heating 97EER Cooling 3.21COP Heating 3.75

Sound power levelCooling

dB(A)

6069

Heating 70

Sound pressure levelCooling

P-Hi: 46 Hi: 38 Me: 36 Lo: 3154

Heating 55Silent mode sound pressure level — 48 /44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 210 x 1,070 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 28 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x2 Propeller fan x1Fan motor (Starting method) W 30 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 13 Hi: 10 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

(b) Twin type

- 49 -

Page 51: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

FDE100VSAWPVHIndoor unit FDE50VH (2 units) Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW3.12

Heating 2.99Max power consumption 10.20

Running currentCooling

A4.6 / 4.8

Heating 4.4 / 4.6Inrush current, max current 5, 15

Power factorCooling

%98

Heating 98EER Cooling 3.21COP Heating 3.75

Sound power levelCooling

dB(A)

6069

Heating 70

Sound pressure levelCooling

P-Hi: 46 Hi: 38 Me: 36 Lo: 3154

Heating 55Silent mode sound pressure level — 48 /44(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 210 x 1,070 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 28 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x2 Propeller fan x1Fan motor (Starting method) W 30 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 13 Hi: 10 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PFA004Z088 B

- 50 -

Page 52: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

FDE125VNAWPVHIndoor unit FDE60VH (2 units) Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 4.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.16

Heating 3.54Max power consumption 6.40

Running currentCooling

A18.3 / 19.1

Heating 15.5 / 16.3Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.00COP Heating 3.95

Sound power levelCooling

dB(A)

60 71Heating

Sound pressure levelCooling

P-Hi: 47 Hi: 41 Me: 37 Lo: 3254

Heating 56Silent mode sound pressure level — 48 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 210 x 1,320 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 33 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 20 Hi: 16 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa 0 0Outside air intake Possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PFA004Z088 B

- 51 -

Page 53: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

FDE125VSAWPVHIndoor unit FDE60VH (2 units) Outdoor unit FDC125VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.16

Heating 3.54Max power consumption 10.20

Running currentCooling

A6.1 / 6.4

Heating 5.2 / 5.5Inrush current, max current 5, 15

Power factorCooling

%99

Heating 98EER Cooling 3.00COP Heating 3.95

Sound power levelCooling

dB(A)

60 71Heating

Sound pressure levelCooling

P-Hi: 47 Hi: 41 Me: 37 Lo: 3254

Heating 56Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 210 x 1,320 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 33 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 20 Hi: 16 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PFA004Z088 B

- 52 -

Page 54: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

FDE140VNAWPVHIndoor unit FDE71VH (2 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.74

Heating 4.21Max power consumption 6.40

Running currentCooling

A20.8 / 21.8

Heating 18.5 / 19.3Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 2.87COP Heating 3.68

Sound power levelCooling

dB(A)

6072

Heating 73

Sound pressure levelCooling

P-Hi: 47 Hi: 41 Me: 37 Lo: 3256

Heating 58Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 210 x 1,320 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 33 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 20 Hi: 16 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52(3/8") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") ②φ 15.88(5/8")x1.0 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PFA004Z088 B

- 53 -

Page 55: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE140VSAWPVHIndoor unit FDE71VH (2 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.74

Heating 3.21Max power consumption 10.20

Running currentCooling

A6.9 / 7.3

Heating 6.2 / 6.5Inrush current, max current 5, 15

Power factorCooling

%99

Heating 98EER Cooling 2.87COP Heating 3.68

Sound power levelCooling

dB(A)

6072

Heating 73

Sound pressure levelCooling

P-Hi: 47 Hi: 41 Me: 37 Lo: 3256

Heating 58Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 210 x 1,320 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 33 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x4 Propeller fan x1Fan motor (Starting method) W 50 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 20 Hi: 16 Me: 13 Lo: 1075

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52(3/8") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") ②φ 15.88(5/8")x1.0 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1G"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 54 -

Page 56: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE140VNAWTVHIndoor unit FDE50VH (3 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.74

Heating 4.21Max power consumption 6.40

Running currentCooling

A20.8 / 21.8

Heating 18.5 / 19.3Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 2.87COP Heating 3.68

Sound power levelCooling

dB(A)

6072

Heating 73

Sound pressure levelCooling

P-Hi: 46 Hi: 38 Me: 36 Lo: 3156

Heating 58Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 210 x 1,070 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 28 77Compressor type & Q'ty — RMT5126SWP3 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x2 Propeller fan x1Fan motor (Starting method) W 30 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 13 Hi: 10 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-TA1G"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

(c) Triple type

- 55 -

Page 57: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem

FDE140VSAWTVHIndoor unit FDE50VH (3 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.74

Heating 3.21Max power consumption 10.20

Running currentCooling

A6.9 / 7.3

Heating 6.2 / 6.5Inrush current, max current 5, 15

Power factorCooling

%99

Heating 98EER Cooling 2.87COP Heating 3.68

Sound power levelCooling

dB(A)

6072

Heating 73

Sound pressure levelCooling

P-Hi: 46 Hi: 38 Me: 36 Lo: 3156

Heating 58Silent mode sound pressure level — 49 /45(Normal/Silent)

Exterior dimensions (Height x Width x Depth) mm 210 x 1,070 x 690 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Plaster white(6.8Y8.9/0.2) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 28 78Compressor type & Q'ty — RMT5126SWP4 ( Twin rotary type )x1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Centrifugal fan x2 Propeller fan x1Fan motor (Starting method) W 30 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/min P-Hi: 13 Hi: 10 Me: 9 Lo: 775

Heating 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Pocket plastic net x2(Washable) —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipments

Overload protection for fan motorFrost protection thermostat

Internal thermostat for fan motorAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingInsulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP20(O.D.26) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Drain hose —Option parts Motion sensor : LB-E

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-TA1G"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 56 -

Page 58: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PCA001Z857 A

ModelItem

SRK100VNAWZRIndoor unit SRK100ZR-W Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW3.19

Heating 3.04Max power consumption 6.40

Running currentCooling

A14.3 / 14.9

Heating 13.6 / 14.2Inrush current, max current 5, 24

Power factorCooling

%97

Heating 97EER Cooling 3.13COP Heating 3.68

Sound power levelCooling

dB(A)

6369

Heating 70

Sound pressure levelCooling P-Hi: 48 Hi: 45 Me: 40 Lo: 27 54Heating P-Hi: 48 Hi: 43 Me: 38 Lo: 30 55

Silent mode sound pressure level — 48 /44(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 339 x 1,197 x 262 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 16.5 77Compressor type & Q'ty — RMT5126SWP3×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x 1 Propeller fan x1Fan motor (Starting method) W 56 x 1 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 24.5 Me: 21.3 Lo: 17.6 ULo: 10.4 75

Heating Hi: 27.5 Me: 23.2 Lo: 19.1 ULo: 13.6 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green, TIMER: Yellow, ECO: Blue

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping — —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP16 Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Clean filter —Option parts —

(6) Wall mounted type (SRK)

(a) Single type

- 57 -

Page 59: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PCA001Z857 A

ModelItem

SRK100VSAWZRIndoor unit SRK100ZR-W Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW3.19

Heating 3.04Max power consumption 10.20

Running currentCooling

A4.8 / 5.1

Heating 4.6 / 4.8Inrush current, max current 5, 15

Power factorCooling

%95

Heating 96EER Cooling 3.13COP Heating 3.68

Sound power levelCooling

dB(A)

6369

Heating 70

Sound pressure levelCooling P-Hi: 48 Hi: 45 Me: 40 Lo: 27 54Heating P-Hi: 48 Hi: 43 Me: 38 Lo: 30 55

Silent mode sound pressure level — 48 /44(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 339 x 1,197 x 262 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 16.5 78Compressor type & Q'ty — RMT5126SWP4×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 56 x 1 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 24.5 Me: 21.3 Lo: 17.6 ULo: 10.4 75

Heating Hi: 27.5 Me: 23.2 Lo: 19.1 ULo: 13.6 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green, TIMER: Yellow, ECO: Blue

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52 (3/8") Pipe φ 9.52 (3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") φ 15.88(5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping — —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP16 Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Clean filter —Option parts —

- 58 -

Page 60: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PCA001Z857 A

ModelItem

SRK100VNAWPZSXIndoor unit SRK50ZSX-W (2 units) Outdoor unit FDC100VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.89

Heating 2.61Max power consumption 6.40

Running currentCooling

A12.7 / 13.3

Heating 11.5 / 12.0Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.46COP Heating 4.29

Sound power levelCooling

dB(A)

59 69Heating 62 70

Sound pressure levelCooling P-Hi: 44 Hi: 39 Me: 31 Lo: 22 54Heating P-Hi: 46 Hi: 41 Me: 33 Lo: 23 55

Silent mode sound pressure level — 48 /44(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 305 x 920 x 220 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 13 77Compressor type & Q'ty — RMT5126SWP3×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 42 x 1 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 14.3 Me: 12.4 Lo: 7.8 ULo: 5.4 75

Heating Hi: 17.3 Me: 14.3 Lo: 9.8 ULo: 6.2 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green, TIMER: Yellow, ECO: Blue

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping — —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP16 Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Clean filter —Option parts —

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

(b) Twin type

- 59 -

Page 61: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

SRK100VSAWPZSXIndoor unit SRK50ZSX-W (2 units) Outdoor unit FDC100VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.) - 11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.) - 12.5(Max.)]

Power consumptionCooling

kW2.89

Heating 2.61Max power consumption 10.20

Running currentCooling

A4.2 / 4.4

Heating 3.8 / 4.0Inrush current, max current 5, 15

Power factorCooling

%99

Heating 99EER Cooling 3.46COP Heating 4.29

Sound power levelCooling

dB(A)

59 69Heating 62 70

Sound pressure levelCooling P-Hi: 44 Hi: 39 Me: 31 Lo: 22 54Heating P-Hi: 46 Hi: 41 Me: 33 Lo: 23 55

Silent mode sound pressure level — 48 /44(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 305 x 920 x 220 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 13 78Compressor type & Q'ty — RMT5126SWP4×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 42 x 1 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 14.3 Me: 12.4 Lo: 7.8 ULo: 5.4 75

Heating Hi: 17.3 Me: 14.3 Lo: 9.8 ULo: 6.2 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green, TIMER: Yellow, ECO: Blue

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping — —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP16 Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Clean filter —Option parts —

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PCA001Z857 A

- 60 -

Page 62: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

SRK125VNAWPZSXIndoor unit SRK60ZSX-W (2 units) Outdoor unit FDC125VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.54

Heating 3.58Max power consumption 6.40

Running currentCooling

A19.9 / 20.8

Heating 15.7 / 16.4Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 2.76COP Heating 3.91

Sound power levelCooling

dB(A)

6271

Heating 63

Sound pressure levelCooling P-Hi: 44 Hi: 41 Me: 33 Lo: 22 54Heating P-Hi: 46 Hi: 42 Me: 34 Lo: 23 56

Silent mode sound pressure level — 48 /45(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 305 x 920 x 220 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 13 77Compressor type & Q'ty — RMT5126SWP3×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 42 x 1 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 16.3 Me: 13.4 Lo: 8.9 ULo: 5.4 75

Heating Hi: 17.8 Me: 13.7 Lo: 10.9 ULo: 6.2 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green, TIMER: Yellow, ECO: Blue

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping — —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP16 Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Clean filter —Option parts —

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PCA001Z857 A

- 61 -

Page 63: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

SRK125VSAWPZSXIndoor unit SRK60ZSX-W (2 units) Outdoor unit FDC125VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.) - 14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.) - 16.0(Max.)]

Power consumptionCooling

kW4.54

Heating 3.58Max power consumption 10.20

Running currentCooling

A6.6 / 7.0

Heating 5.2 / 5.5Inrush current, max current 5, 15

Power factorCooling

%99

Heating 99EER Cooling 2.76COP Heating 3.91

Sound power levelCooling

dB(A)

6271

Heating 63

Sound pressure levelCooling P-Hi: 46 Hi: 41 Me: 33 Lo: 22 54Heating P-Hi: 46 Hi: 42 Me: 34 Lo: 23 56

Silent mode sound pressure level — 48 /45(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 305 x 920 x 220 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 13 78Compressor type & Q'ty — RMT5126SWP4×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 42 x 1 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 16.3 Me: 13.4 Lo: 8.9 ULo: 5.4 75

Heating Hi: 17.8 Me: 13.7 Lo: 10.9 ULo: 6.2 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green, TIMER: Yellow, ECO: Blue

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping — —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP16 Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Clean filter —Option parts —

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PCA001Z857 A

- 62 -

Page 64: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

SRK140VNAWPZRIndoor unit SRK71ZR-W (2 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.26

Heating 4.03Max power consumption 6.40

Running currentCooling

A18.7 / 19.6

Heating 17.7 / 18.5Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.19COP Heating 3.85

Sound power levelCooling

dB(A)

57 72Heating 60 73

Sound pressure levelCooling P-Hi: 44 Hi: 41 Me: 37 Lo: 25 56Heating P-Hi: 46 Hi: 39 Me: 35 Lo: 28 58

Silent mode sound pressure level — 49 /45(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 339 x 1,197 x 262 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 15.5 77Compressor type & Q'ty — RMT5126SWP3×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 56 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 20.5 Me: 18.6 Lo: 16.2 ULo: 10.4 75

Heating Hi: 25.0 Me: 19.8 Lo: 17.3 ULo: 13.3 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green , TIMER: Yellow , HI POWER: Green , 3D AUTO: Orange

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52(3/8") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") ②φ 15.88(5/8")x1.0 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping Liquid line : 0.78 / Gas line : 0.72 —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with (VP16) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24

Standard accessoriesMounting kit, Clean filter

(Allergen clear filter ×1 , Photocatalytic washable deodorizing filter × 1)

Option parts —

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PCA001Z857 A

- 63 -

Page 65: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PCA001Z857 A

ModelItem

SRK140VSAWPZRIndoor unit SRK71ZR-W (2 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.26

Heating 4.03Max power consumption 10.20

Running currentCooling

A6.2 / 6.5

Heating 5.9 / 6.2Inrush current, max current 5, 15

Power factorCooling

%99

Heating 99EER Cooling 3.19COP Heating 3.85

Sound power levelCooling

dB(A)

57 72Heating 60 73

Sound pressure levelCooling P-Hi: 44 Hi: 41 Me: 37 Lo: 25 56Heating P-Hi: 46 Hi: 39 Me: 35 Lo: 28 58

Silent mode sound pressure level — 49 /45(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 339 x 1,197 x 262 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 15.5 78Compressor type & Q'ty — RMT5126SWP4×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 56 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 20.5 Me: 18.6 Lo: 16.2 ULo: 10.4 75

Heating Hi: 25.0 Me: 19.8 Lo: 17.3 ULo: 13.3 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green , TIMER: Yellow , HI POWER: Green , 3D AUTO: Orange

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 9.52(3/8") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 15.88 (5/8") ②φ 15.88(5/8")x1.0 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping Liquid line : 0.78 / Gas line : 0.72 —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with (VP16) Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24

Standard accessoriesMounting kit, Clean filter

(Allergen clear filter ×1 , Photocatalytic washable deodorizing filter × 1)

Option parts —

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-WA1"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

- 64 -

Page 66: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PCA001Z857 A

ModelItem

SRK140VNAWTZSXIndoor unit SRK50ZSX-W (3 units) Outdoor unit FDC140VNA-W

Power source 1 Phase, 220 - 240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.26

Heating 3.74Max power consumption 6.40

Running currentCooling

A18.7 / 19.6

Heating 16.4 / 17.2Inrush current, max current 5, 24

Power factorCooling

%99

Heating 99EER Cooling 3.19COP Heating 4.14

Sound power levelCooling

dB(A)

57 72Heating 62 73

Sound pressure levelCooling P-Hi: 44 Hi: 39 Me: 31 Lo: 22 56Heating P-Hi: 46 Hi: 41 Me: 33 Lo: 23 58

Silent mode sound pressure level — 49 /45(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 305 x 920 x 220 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 13 77Compressor type & Q'ty — RMT5126SWP3×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 42 x 1 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 14.3 Me: 12.4 Lo: 7.8 ULo: 5.4 75

Heating Hi: 17.3 Me: 14.3 Lo: 9.8 ULo: 6.2 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green, TIMER: Yellow, ECO: Blue

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping — —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP16 Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Clean filter —Option parts —

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-TA1"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

(c) Triple type

- 65 -

Page 67: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

ModelItem

SRK140VSAWTZSXIndoor unit SRK50ZSX-W (3 units) Outdoor unit FDC140VSA-W

Power source 3 Phase, 380 - 415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.) - 14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.) - 16.5(Max.)]

Power consumptionCooling

kW4.26

Heating 3.74Max power consumption 10.20

Running currentCooling

A18.7 / 19.6

Heating 16.4 / 17.2Inrush current, max current 5, 15

Power factorCooling

%99

Heating 98EER Cooling 3.19COP Heating 4.14

Sound power levelCooling

dB(A)

59 72Heating 62 73

Sound pressure levelCooling P-Hi: 44 Hi: 39 Me: 31 Lo: 22 56Heating P-Hi: 46 Hi: 41 Me: 33 Lo: 23 58

Silent mode sound pressure level — 49 /45(Normal/Silent)Exterior dimensions (Height x Width x Depth) mm 305 x 920 x 220 845 x 970 x 370Exterior appearance(Munsell color)(RAL color )

Fine snow(8.0Y9.3/0.1) near equivalent(RAL 9003) near equivalent

Stucco white(4.2Y7.5/1.1) near equivalent(RAL 7044) near equivalent

Net weight kg 13 78Compressor type & Q'ty — RMT5126SWP4×1Compressor motor (Starting method) kW — Direct line startRefrigerant oil (Amount, type) L — 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Pre-charged up to the piping length of 30m)Heat exchanger Louver fin & inner grooved tubing M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Tangential fan x1 Propeller fan x1Fan motor (Starting method) W 42 x 1 < Direct line start > 86 < Direct line start >

Air flow Cooling

m3/minHi: 14.3 Me: 12.4 Lo: 7.8 ULo: 5.4 75

Heating Hi: 17.3 Me: 14.3 Lo: 9.8 ULo: 6.2 73Available external static pressure Pa 0 0Outside air intake Not possible —Air filter, Quality / Quantity Polypropylene net (Washable) x 2 —Shock & vibration absorber Rubber sleeve(for fan motor) Rubber sleeve (for fan motor & compressor)Electric heater W — 20(Crank case heater)

Operation control

Remote control (Option) Wired : RC-EX3A, RC-E5 , RCH-E3 Interface kit : SC-BIKN2-ERoom temperature control Thermostat by electronicsOperation display RUN: Green, TIMER: Yellow, ECO: Blue

Safety equipmentsInternal thermostat for fan motor

Frost protection thermostatAbnormal discharge temperature protection

Installation data

Refrigerant piping size (O.D)Liquid line

mmI/U φ 6.35(1/4") ②φ 9.52(3/8")x0.8 ①φ 9.52(3/8")x0.8 O/U φ 9.52 (3/8")

Gas line φ 12.7 (1/2") ②φ 12.7(1/2")x0.8 ①φ 15.88 (5/8")x1.0 φ 15.88 (5/8")Connecting method Flare piping Flare pipingAttached length of piping — —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50Vertical height diff. between O/U and I/U m Max.50 (Outdoor unit is higher) Max.15 (Outdoor unit is lower)Drain hose Hose connectable with VP16 Hole size φ 20 x 3pcs

Drain pump, max lift height mm — —Recommended breaker size A —L.R.A. (Locked rotor ampere) A 5.0Interconnecting wires Size x Core number φ 1.6mm x 3 cores + earth cable / Terminal block (Screw fixing type) IP number IPX0 IP24Standard accessories Mounting kit, Clean filter —Option parts —

The pipe length is 7.5m.Notes (1) The data are measured at the following conditions.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) Select the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.(6) Indoor unit specifications for one unit. Capacity and operation data is two indoor units are combined and run together.(7) Branching pipe set "DIS-TA1"×1(Option). ① : Pipe of O/U-Branch, ② : Pipe of Branch-I/U

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PCA001Z857 A

- 66 -

Page 68: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

PJF000Z552

15.88(

5 8")(F

lare)

9.52(3

8")(F

lare)

71

d

1.2 EXTERIOR DIMENSIONS(1) Indoor units

(a) Ceiling cassette-4 way type (FDT)

Models FDT50VH, 60VH, 71VH

- 67 -

Page 69: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Models FDT100VH, 125VH, 140VH

PJF000Z553

- 68 -

Deco

rativ

e pa

nel

Note

s(1) T

he m

odel

nam

e la

bel is

atta

ched

to th

e

con

trol b

ox lid

. 

(2) S

uspe

nsio

n bo

lt pi

tch

P1,P

2 is

adju

stab

le

by

a pa

ttern

of t

he ri

ght t

able

. 

  (

3) D

raft

prev

entio

n fu

nctio

n (※

1) is

pro

vided

on

the

pane

l T-P

SAE-

5AW

-E o

nly.

Unit:

mm

Obsta

cle

Mak

e a

spac

e of

500

0 or

mor

e be

twee

nth

e un

its w

hen

insta

lling

mor

e th

an o

ne.

or more

or mo

re10

00

1000

Spac

e fo

r ins

talla

tion

and

serv

ice

177

02

770ー

800

725

725ー

770

P1P2

Patte

rnSy

mbol

Susp

ensio

n bo

lt pitc

h ra

nge

ACo

ntent

Gas p

iping

φ15

.88(5/

8")(Fla

re)B

Liquid

pipin

9.52(3

/8")(

Flare)

CDr

ain pi

ping

VP25(

O.D.

32)

DHo

le for

wirin

gF

Susp

ensio

n bolt

s(M

10 or

M8)

G

Hang

er pla

te for

susp

ensio

n bolt

(Max. drain lift)

H1φ

125(K

nock

out)

Contr

ol bo

x

Symb

ol

H2φ

200(K

nock

out)

Outsi

de ai

r ope

ning

for du

cting

Air ou

tlet o

penin

gfor

ducti

ng

Contr

olbo

x

Susp

ensio

n bolt

s pitc

h:P1(7

78)

Suspension bolts pitch:P2(725)

(Ins

talled

on si

te)

Drain

hose

piec

e(A

cces

sory)

Hole

Holes

for

tappin

g scre

ws

Holes

for

tappin

g scre

ws

(Kno

ck ou

t)

Hole

Hole

Holes

for

tappin

g sc

rews

Air su

pply

Air re

turn g

rille

Draft

prev

entio

n fun

ction(

※1)

□630

□950

860ー

910(C

eiling

hole

size)

568420

42024

5 303

333

50 or more140

188

□840

131173

298 35

215ー

245

850 or less

140100

10060140

140

6-φ4

140100

130

240

1406-φ

420

076

112

137

129

5038

9940

65

5-φ4

167

4413

H1,2

G

H1,2

H1,2

BA

FC

H1H2

H1,2

D

G

Unit:

mm

AGa

s pipi

ngφ

15.88(

5/8")(

Flare)

BLiq

uid pi

ping

φ9.5

2(3/8

")(Fla

re)C

Drain

pipin

gVP

25(O.

D.32)

DHo

le for

wirin

gF

Susp

ensio

n bolt

s(M

10 or

M8)

G

Spac

e for

instal

lation

and s

ervice

Obsta

cle

H1,2

G

H1,2

H1,2

Drain

hose

piec

e

BA

FC

(Max. Drain lift)

H1H2

φ12

5(Kno

ck ou

t)φ

200(K

nock

out)

H1,2

D

G

177

02

770-8

0072

572

5-770

P1P2

Patte

rnSymb

olPit

ch ar

ea ta

ble of

susp

ensio

n bolt

Symb

olCo

ntent

Outsid

e air o

penin

gfor

ductin

gAir

outle

t ope

ning

for du

cting

(Kno

ck ou

t)

or more

or mo

re

Make

a sp

ace o

f 500

0 or m

ore be

twee

n th

e unit

s whe

n ins

tallin

g more

than

one.

Holes

for

tappin

g scre

wsHo

les fo

r tap

ping s

crews

Deco

rative

pane

l

Air su

pply

Air re

turn g

rille

Susp

ensio

n bolt

s pitc

h:P1

(Ceil

ing ho

le siz

e)

box

Contr

ol

Suspension bolts pitch:P2

(Acc

esso

ry)(I

nstal

led on

site)

susp

ensio

n bolt

Hang

er pla

te for

Contr

ol bo

x

Hole

Hole

Holes

for

tappin

g sc

rews

Hole

H1 H2

Anti d

raft fu

nctio

n(※1)

Note

s (1)

The

mod

el na

me

label

is at

tach

ed to

the

con

trol b

ox lid

. 

2)Su

spen

sion

bolt p

itch

P1,P

2 is

adjus

table

b

y a p

atte

rn o

f the

righ

t tab

le.    (

3)Se

ction

1(※

1)is

prov

ided

on th

e pa

nel

T-P

SAE-

5AW

-E o

nly.

1000

1000

□630

□950

(778)

860-9

10

(725)568

420

42024

5 303

333

50 or more140

188

□840

131173

298 35

215-2

45

850 or less

140100

10060140

140

6-φ4

140100

130

240

1406-φ

420

0

76

112

137

129

5038

9940

65

5-φ4

167

4413

Page 70: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Unit:

mm

ACo

ntent

Gas p

iping

BLiq

uid pi

ping

CDr

ain pi

ping

VP25(

O.D.

32)

D1Po

wer s

ource

conn

ectio

n

FSu

spen

sion b

olts

(M10

or M

8)

G

Spac

e fo

r ins

talla

tion

and

serv

ice

Obsta

cle

Mak

e a

spac

e of

400

0 or

mor

e be

twee

n

125(K

nock

out)

Symb

ol

for du

cting

Outsi

de ai

r ope

ning

for du

cting

Air o

utlet

open

ing

or more

or mo

re

the

units

whe

n in

stal

ling

mor

e th

an o

ne.

(Kno

ck ou

t)

Note

s (1)

The

mod

el n

ame

labe

l is a

ttach

ed to

the

cont

rol b

ox lid

. 

2)Th

is un

it is

desig

ned

for 2

x2 g

rid c

eilin

g.

If it

is in

stal

led

on a

cei

ling

othe

r tha

n 2x

2 gr

id c

eilin

g,

prov

ide

an in

spec

tion

open

ing

on th

e co

ntro

l box

sid

e. 

  

 (3)

Draf

t pre

vent

ion

func

tion(

※) i

s pr

ovid

ed o

n th

e pa

nel T

C-PS

AE-5

AW-E

onl

y.

φ6.3

5(1/4

")(Fla

re)

Hang

er p

late

for

box

susp

ensio

n bo

lt

(Ac

cess

ory)

(In

stalle

d on

site)

Drain

hos

e pie

ce

Draf

t pre

vent

ion fu

nctio

n(※

Deco

rative

pane

l

Air s

upply

Air r

etur

n gr

ille

Hole Ho

le

6-φ4

Holes

for

tappin

g scre

ws

4-φ4

Holes

for

tappin

g scre

ws

D2Re

mote

contr

ol co

de an

dsig

nal w

iring c

onne

ction

Contr

ol

JIns

pecti

on op

ening

450×

450

φ12

.7(1/

2")(Fla

re)

H

H

H

BA

CF

G

D2D1

H GD1

Cont

rol b

ox

J

Insp

ectio

n op

enin

g(Re

fer t

o no

te(2)

1000

1000

530

530

□570

248

130190

10210

130

288

110

50

46722

517

518

5

354325

73

184

63

Susp

ensio

n bo

lts p

itch

Suspension bolts pitch(

)()

8960

140

140

88 77

89

100

100

158

Max. drain lift ()or less

-245

215

850

or more

□400

□620

□576

-600

□576

-610

Ceilin

g ho

le siz

e(

)Sy

stem

ceilin

g ho

le siz

e(

φ10

0

150-200

(b) Ceiling cassette-4 way compact type (FDTC)

Models FDTC50VH, 60VH

PJF000Z515 A

- 69 -

Page 71: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

(c) Duct connected-High static pressure type(FDU)

Models FDU100VH, 125VH, 140VH

PJG000Z579

- 70 -

(Duct dimension)

(Du

ct dim

ensio

n)

Note(c)

Fan unit

View M

tapping screwsHoles for

Return air duct

Hole

A Gas pipingB Liquid piping

D Hole for wiringE Suspension bolts M10

FOutside air opening

Air outlet openingG

Symbol Content

φ9.52(3/8")(Flare)

for ducting

for ducting

Drain pipingC2

(Gravity drainage)

φ15.88(5/8")(Flare)

(Knock out)

(Knock out)

Drain hose piece(Accessory)

(Installed on site)

H Inspection hole (450×450)

φ170

φ124

φ170

tapping screwsHoles for

Space for installation and service

or m

ore

or m

ore

or m

ore

or m

ore

(Case 1) From side of unitSelect either of two cases to keep space for installation and services.

or m

ore

or m

ore

(Case 2) From bottom of unit

Notes(a)There must not be obstacle to draw out 2 fan units. For fan units maintenance, refer to the service manual. (b)Install refrigerant pipes, drain pipe, and wiring so as not to cross marked area. (c)The case that pipes are installed to upper(bottom)of fan unit, keep space of 60mm or more to upper(bottom)of unit.

C1 Drain piping VP25(O.D.32)

VP20

Unit:mm

4-φ4

(Suspension bolts pitch)

Air supply duct

Control box

(Duct dimension)

(Du

ct dim

ensio

n)

18 1368 181404

suspension boltHanger plate for

104 1200 104

92 250

184.

513

4.5

467

405468

63573830 30

280

71

59

86284

152 285

23.5

235

21.5

64 1280 64

139

□90

600

(M

ax. d

rain

lift)

(Su

spen

sion

bolts

pitc

h)28

530

180

or le

ss

113

69

295�325

4317

0

4-φ4

100015

0─ 200

100―200

100

Slab

2020

Note(a)370

Ceiling

Note(b)

600

1720

100

Inspectionhole

725

Note(a)

1550

F G

M

C2

D

AC1

BG

F

E

H

Note(1)The model name label    is attached on the lid    of the control box.

Page 72: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Notes (a) There must not be obstacle to draw out fan unit. For fan unit maintenance, refer to the service manual. (b) Install refrigerant pipes, drain pipe,and wiring so as not to cross marked area. (c) The case that pipes are installed to upper (bottom) of fan unit, keep space of 60mm or more to upper (bottom) of unit.

295~325

Note (c)

Fan unit

View M

tapping screwsHoles for

Return air duct

Drain hose piece(Accessory)

(Installed on site)

Hole

tapping screwHoles for

A Gas pipingB Liquid piping

C1 Drain piping VP25(O.D.32)

D Hole for wiringE Suspension bolts (M10)

FOutside air opening

Air outlet openingG

Symbol Content

φ12.7(1/2")(Flare)

for ducting

for ducting

(φ150)(Knock out)

(φ125)(Knock out)

Drain pipingC2

(Gravity drainage)VP20

φ6.35(1/4")(Flare)

H Inspection opening (450×450)

φ170

φ124

φ170

tapping screwsHoles for

Space for installation and service

or m

ore

or m

ore

or m

ore

or m

ore

(Case 1) From side of unit

or m

ore

or m

ore

(Case 2) From bottom of unit

(Suspension bolts pitch)

Air supply duct

Control box

600

(M

ax. d

rain

lift)

or le

ss

(Duct dimension)

(Du

ct d

imen

sion)

4317

028

472

135

18 750 18786

suspension boltHanger plate for

55 680 55

76

6758

86284

152 262

41200

39

65 660 65

139

□90

46 200200 4620031

170

31

280

467

413471

510635 3030

105

175

250

(Duct dimension)

(Du

ct d

imen

sion)

69 113

100015

0-20

0

100-200

100

Slab

2020

Note (a)

370Ceiling

Note (b)

600

1100 10

0

Inspectionopening

620

Note (a)

Unit:mm

1550

(Su

spen

sion

bolts

pitc

h)

F G

M

E

C2

D

A

1C

B

G

F

H

Note(1) The model name label is attached on the lid of the control box.

Select either of two cases to keep space for installation and services.

12-φ4

4-φ44-φ4

(d) Duct connected-Low / Middle static pressure type (FDUM)

Model FDUM50VH

PJG000Z485

- 71 -

Page 73: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Models FDUM60VH, 70VH

PJG000Z486

- 72 -

295~325

View M

tapping screwsHoles for

Return air duct

Drain hose piece(Accessory)

(Installed on site)

tapping screwHoles for

A Gas piping

Model

B Liquid piping

C1 Drain piping

D Hole for wiringE Suspension bolts (M10)

FOutside air opening

Air outlet openingG

Symbol Content

φ6.35(1/4")(Flare)

for ducting

for ducting

Drain pipingC2

(Gravity drainage)

(φ150)(Knock out)

(φ125)(Knock out)

φ12.7(1/2")(Flare)

60 71

φ9.52(3/8")(Flare)

φ15.88(5/8")(Flare)

H Inspection opening (450×450)

Hole

φ170

φ124

φ170

tapping screwsHoles for 4-φ4

(Suspension bolts pitch)

Control box

600

(M

ax. d

rain

lift)

or le

ss

(Duct dimension)

(Du

ct d

imen

sion)

(Su

spen

sion

bolts

pitc

h)

2847

213

5

18 950 18986

suspension boltHanger plate for

55 880 55

76 250 17

510

5

467

413471

51063530 30

280

67

86284

152 262

41200

39

65 860 65

139

□90

46 4×200=800 46

3117

031

14-φ4

58

113

Air supply duct

4317

0(

Duct

dim

ensio

n)

(Duct dimension)

69

4-φ4

200

1550M

C2

D

A

C1

B

G

F

F G

E

Space for installation and service

or m

ore

or m

ore

or m

ore

or m

ore

(Case 1) From side of unitSelect either of two cases to keep space for installation and services.

or m

ore

or m

ore

(Case 2) From bottom of unit

Notes (a) There must not be obstacle to draw out fan unit. For fan unit maintenance, refer to the service manual. (b) Install refrigerant pipes, drain pipe,and wiring so as not to cross marked area. (c) The case that pipes are installed to upper (bottom) of fan unit, keep space of 60mm or more to upper (bottom) of unit.

100015

0-20

0

100-200

100

Slab

2020

Note (a)

370Ceiling

Note (b)

600

1300 10

0

Inspectionopening

620

H

Note (c)

Fan unit

Note (a)

Note(1) The model name label is attached on the lid of the control box.

VP25( O.D.32)

VP20

Page 74: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Models FDUM100VH, 125VH, 140VH

PJG000Z487

- 73 -

Note c

Fan unit

View M

Holes fortapping screws

Return air duct

Hole

tapping screwHoles for

A Gas pipingB Liquid piping

D Hole for wiringE Suspension bolts (M10)

FOutside air opening

Air outlet openingG

Symbol Content

9.52(3 8")(Flare)

for ducting

for ducting

Drain pipingC2 (Gravity drainage)

15.88(5 8")(Flare)

( 150)(Knock out)

( 125)( Knock out)

Drain hose piece(Accessory)(Installed on site)

H Inspection opening 450×450

170

124

170

Holes fortapping screws

Space for installation and service

or m

ore

or m

ore

or m

ore

or m

ore

(Case 1) From side of unitSelect either of two cases to keep space for installation and services.

or m

ore

or m

ore

(Case 2) From bottom of unit

Note(1) The model name labelis attached on the lid

of the control box.

Notes a) There must not be obstacle to draw out 2 fan units. For fan units maintenance, refer to service manual.

b Install refrigerant pipes, drain pipe,and wiring so as not to cross marked area.

c The case that pipes are installed to upper bottom of fan unit, keep space of 60mm or more to upper bottom of unit.

C1 Drain piping VP25 O.D.32

VP20

Unit:mm

4 4

Suspension bolts pitch

Air supply duct

Control box

Duct dimension

Duct

dim

ensio

n

18 1368 181404

Hanger plate forsuspension bolt

104 1200 104

92 250

184.

513

4.5

467

405468

63573830 30

280

71

59

86284

152 285

23.5

235

21.5

64 1280 64

139

90

100 100

24.5

205

24.5 14 4

600

Max

. dra

in lif

t

Susp

ensio

n bo

lts p

itch

2853

018

0

or le

ss

4 280=1120

113

69

295 325

4317

0Du

ct d

imen

sion

Duct dimension

280

4 4

100015

0 200

100 200

100

Slab

2020

Note (a)370

Ceiling

Note (b)

600

1720

100

Inspectionopening

725

Note (a)

1545

F G

M

C2

D

AC1

BG

F

E

H

Page 75: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

(e) Ceiling suspended type (FDE)

Model FDE50VH

PFA004Z084

C 2

C 1,C

2

C 1,C

2

C 1A

B

GE

F

D

B A

- 74 -

Page 76: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

C 2C 1

AB

AB

D

C 1,C

2

C 1,C

2

EG

F

Models FDE60VH, 71VH

PFA004Z085

- 75 -

Page 77: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Models FDE100VH, 125VH, 140VH

PFA004Z086

- 76 -

C 1,C

2

C 1,C

2

C 2C1

A

E

GF

AB

B

D

Page 78: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

RLF000Z202

(f) Wall mounted type (SRK)

Models SRK50ZSX-W, 60ZSX-W

- 77 -

Hole

on w

all fo

r righ

t rea

r pipi

ngHo

le on

wall

for l

eft r

ear p

iping

Gas p

iping

Outle

t for

pipi

ngDr

ain h

ose

FEC D

Sym

bol

A

(φ

65)

VP16

Cont

ent

(φ

65)

φ9.

52(

3/8"

)(

Flar

e)

Wire

less r

emot

e co

ntro

l

Wire

d re

mot

e co

ntro

l(

Optio

n)

φ6.

35(

1/4"

)(

Flar

e)Liq

uid p

iping

B

Uni

t:mm

Not

es(

1)Th

e m

odel

nam

e la

bel i

s at

tach

ed 

   

on th

e rig

ht s

ide

of th

e un

it.

2)To

con

nect

the

wire

d re

mot

e co

ntro

l, 

   

the

inte

rface

kit(

SC

-BIK

N2-

E) is

requ

ired.

□120

19

6024

167

□120

19

920

305

6045

55

6035

55

59.5 12.5

45

59.5 12.5

61

220

3

100

100

118.

511

8.5

683

145

630

145

176

568

176

460

460

10.3 277.3 17.4

56.4

47

48.6

76.6

47

6570

548

533

65 120

88.6

(Service space)

480

(Se

rvice

spac

e)

(Service space)

(Se

rvice

spac

e)

Outle

t for

dow

nwar

d pip

ing(

Refe

r to

the

top

view)

Unit

Insta

llatio

n bo

ard

Term

inal b

lock

Spac

e fo

r ins

talla

tion

and

serv

ice w

hen

viewi

ng fr

om th

e fro

nt

DB

AE

C

FF

FF

Page 79: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

43.5

64

55

G

Hole

on w

all fo

r righ

t rea

r pipi

ngHo

le on

wall

for l

eft r

ear p

iping

Gas p

iping

Outle

t for

wirin

g(on

bot

h sid

e)Dr

ain h

ose

Liquid

pipi

ng

FEC DB

Sym

bol

A

(φ

65)

VP16

Cont

ent

(φ

65)

Outle

t for

pipi

ng(on

bot

h sid

e)G

Wire

less

rem

ote

cont

rol

Wire

d re

mot

e co

ntro

l(

Opt

ion)

φ6.

35(1/

4")(

Flar

e)φ

15.8

8(5/

8")(

Flar

e)SR

K 71

φ9.

52(3/

8")(

Flar

e)SR

K 10

0

Spac

e fo

r Ser

vice

Unit

Spac

e fo

r ins

talla

tion

and

serv

ice w

hen

viewi

ng fr

om th

e fro

nt

768

157

48 240

6.7322.4

214.

521

4.5

883

157

10

326

2

1964

55

47

5377

47

1197

339

150

50Sp

ace

for s

ervic

e

Space for service Space for service 15100

780

715 75

9

55

Insta

llatio

n bo

ard

Outle

t for

dow

nwar

d pip

ing(

Refe

r to

the

top

view)

Term

inal b

lock

60

24043

470

363.

536

3.5

568.

556

8.5

1160

Unit:m

m

Note

s(1)

The

mod

el n

ame

labe

l is a

ttach

ed  

 on

the

unde

rsid

e of

the

indo

or u

nit.

(2)

To c

onne

ct th

e wi

red

rem

ote

cont

rol,

  

 th

e in

terfa

ce k

it(SC

-BIK

N2-E) i

s re

quire

d.

DE

CA

B

G

G F

□120

19

6024

167

Models SRK71ZR-W, 100ZR-W

RLD000Z005 A

- 78 -

Page 80: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

51

40

40

103

110 50195242279

970

5016

55

37039 3941019 19

56

60

325

263

39

7618

958

020

160

16

10316

502752

110 50195

67

70 50150

41

Term

inal b

lock

Note

s (

1) It

mus

t not

be

surro

unde

d by

wal

ls on

the

four

sid

es.

 (2)

The

uni

t mus

t be

fixed

with

anc

hor b

olts

. An

anch

or b

olt m

ust n

ot

pr

otru

de m

ore

the

15m

m.

 (3)

Whe

re th

e un

it is

subj

ect t

o st

rong

win

ds, l

ay it

in s

uch

a

dire

ctio

n th

at th

e bl

ower

out

let f

aces

per

pend

icula

rly

to th

e do

min

ant w

ind

dire

ctio

n. (

4) L

eave

1m

or m

ore

spac

e ab

ove

the

unit.

 (5)

A w

all in

fron

t of t

he b

lowe

r out

let m

ust n

ot e

xcee

d th

e un

its h

eigh

t. (

6) T

he m

odel

nam

e la

bel is

atta

ched

on

the

lowe

r rig

ht c

orne

r of t

he fr

ont p

anel

.

φ15

.88(

5/8")(

Flar

e)Co

ntent

CPi

pe/

cable

dra

w-ou

t hole

D EAn

chor

bolt

hole

Drain

disc

harg

e ho

le

Symb

ol

BASe

rvice

valve

conn

ectio

n(ga

s side)

M10

×4 p

laces

φ20

×3 p

laces

Serv

ice va

lve co

nnec

tion(

liquid

side)

φ9.

52(3/

8")(

Flar

e)

L2L4

L2 L3 L4L130

015

015

0

OpenI

Open

150

150

500

Open

150

3005

FCa

ble d

raw-

out h

oleφ

30×3

plac

es

Exam

ples o

f

Dimen

sions ins

tallation

9

Unit:

mm

84510

C3

C1

C2Cent

er o

f Gra

vity

FDC1

00,12

5,140

VNA-

W37

838

0C1

178

178

370

382C2

C3

FDC1

00,12

5,140

VSA-

W

MOD

ELL1L3

Intak

e

Outle

t

Intak

e

Min

imum

inst

alla

tion

spac

e

spac

eSe

rvice

C

E

C

D

AB

FF

B

A

CCF

(2) Outdoor units

Model FDC100VNA-W, 125VNA-W, 140VNA-W

100VSA-W, 125VSA-W, 140VSA-W

PCA001Z853

- 79 -

Page 81: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Installation space

30mm

30mm

30mm

120mm

配線

30mm 30mm

30mm

120m

m

Wiring

R/C temperature sensor

Secure minimum spaces for disassembling the case.Upper left and Upper right sides ……30mm or moreBottom side…120mm or moreIf using L-shaped screwdriver, 50mm or more is available.

Dimensions (Viewed from front)

37 23 23

固定穴

18.3

83.5

120

19120

37 23 23 19120

Fixing holes 83.5

120

18.3

≦ 200 m 0.5 mm2 x 2 cores

≦ 300m 0.75 mm2 x 2 cores

≦ 400m 1.25 mm2 x 2 cores

≦ 600m 2.0 mm2 x 2 cores

● Do not install the remote control at following places. 1) It could cause break-down or deformation of remote control.・Where it is exposed to direct sunlight・Where the ambient temperature becomes 0 °C or below, or 40 °C or above・Where the surface is not flat・Where the strength of installation area is insufficient

2) Moisture may be attached to internal parts of the remote control, resulting in a display failure.・Place with high humidity where condensation occurs on the remote control・Where the remote control gets wet

3) Accurate room temperature may not be detected using the temperature sensor of the remote control.・Where the average room temperature cannot be detected・Place near the equipment to generate heat・Place affected by outside air in opening/closing the door・Place exposed to direct sunlight or wind from air-conditioner・Where the difference between wall and room temperature is large

4) When you are using the automatic grille up and down panel in the IU, you may not be able to confirm the up and down motion.・Where the IU cannot be visually confirmed

● When installing the unit at a hospital, telecommunication facility, etc., take measures tosuppress electric noises.

It could cause malfunction or break-down due to hazardous effects on the inverter, private power generator,high frequency medical equipment, radio communication equipment, etc.The influences transmitted from the remote control to medical or communication equipment could disrupt medicalactivities, video broadcasting or cause noise interference.

R/C cable:0.3mm2x2 coresWhen the cable length is longer than 100 m, the max size for wires used in the R/C case is 0.5 mm2 . Connect them to wires of larger size near the outside of R/C. When wires are connected, take measures to prevent water, etc. from entering inside.

Adapted RoHS directive

(3) Remote control (Option parts)

(a) Wired remote control

Model RC-EX3A

PJZ000Z333

- 80 -

Page 82: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

TEMP ON/OFF

48

120

L C D

Wall surface

Wiring

Electrical boxNot included

19

Wiring specifications

Exposed mounting

2346

11.5 11

Remote control outline

12045

83.5

42

120

Remote control installation dimensions

Wiring oulet

Installation hole12×7 slot hole

9.5×5 slot hole 4 places

1 Installation screw for remote controlM4 screw (2 pieces)

44

1) If the prolongation is over 100m, change to the size below. But, wiring in the remote control case should be under 0.5mm2. Change the wire size outside of the case according to wire connecting. Waterproof treatment is necessary at the wire connecting section. Be careful about contact failure.

Length Wiring thickness

100 to 200m 0.5mm2×2 cores0.75mm2×2 cores1.25mm2×2 cores2.0mm2×2 cores

Under 300mUnder 400mUnder 600m

Upper part

Lower part

Lower case

Sheath

Upper cace

Board

Wiring

Upper

Lower

X Y

Sheath

Upper cace

Board

Wiring

Upper

Lower

YX

Tighten the screws aftercutting off the thin part ofscrew mounting part.

Embedded mounting

The peeling-off length of sheath

The peeling-off length of sheath

In case of pulling out fromupper left

In case of pulling out from upper left

In case of pulling out from upper left

X wiring : 170mmY wiring : 190mm

Pulling out from center

X wiring : 215mmY wiring : 195mm

Pulling out from upper left

In case of pulling out from center

In case of pulling out from center

In case of pulling out from center

Wiring outletCut off the upper thin part of remote control lower case with a nipper or knife,and grind burrs with a file etc.

0.3mm2×2 cores

X, Y terminal blockAttach M3 screw with washer

Unit:mm

Exterior appearance(Munsell color)

Pearl white(N8.5) near equivalent

Model RC-E5

PJZ000Z295

- 81 -

Page 83: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

(b) Wireless remote controlRCN-E2(Option parts) (Except SRK series)

60 2416

7

(3) Remote control

Unit : mm

60 24

167

SRK series only

- 82 -

Unit: mm

Unit: mm

Page 84: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D1.3 ELECTRICAL WIRING

(1) Indoor units

(a) Ceiling cassette-4 way type (FDT)

Models FDT50VH, 60VH, 71VH, 100VH, 125VH, 140VH

PJF000Z554

- 83 -

Notes

1.

ind

icates

wirin

g on s

ite.

  

2. Se

e the

wirin

g diag

ram of

outsi

de un

it abo

ut the

line b

etwee

n

  

3. U

se tw

in co

re co

rd(0.3

mm2 )

at rem

ote co

ntrol

line.

  

See

spec

shee

t of re

mote

contr

ol in

case

that

the to

tal le

ngth

is mo

re tha

n 100

m.

indoo

r unit

and o

utdoo

r unit

.

  

4. D

o not

put re

mote

contr

ol lin

e alon

gside

powe

r sou

rce lin

e. 

  5.

Secti

on 1(

※1)

is pro

vided

on th

e pan

el T-P

SAE-

5AW-

E only

.

CNTA BL

12

Th -A

CNI

BL

CNJ1 WH

LM4

LM1

LM2

LM3

CNJ2 GY

M AM4

M AM1

1

M AM2

M AM3

6 5 4 3 2 1

CNN

YE

Thi-R

3

Thi-R

2

Thi-R

1t°t°t°

2 1CN

CWHCN

LBK

CNH

BK

12

t°I

SW6

SW7

DM

12 CN

RWH

M

CNM1 WH

FMi M

F2

CNB

BK

LED・

3LE

D・2

23

45

12

34

51

23

45

12

34

5

12

34

56

78

910

1112

1314

1516

1718

1920

3 1 2 1

RD RDRDRDYEBKBK YE

2

14

56

7

Pow

er c

ircui

t

XR1

XR5

(Oper

ation)

(Heat

ing)

(Com

presso

r ON)

(Insp

ection

Prep

are on

site

XR2

XR3

XR4

1 2 3 4 5 6

FS

X YX Y

Rem

ote

cont

rol

TB2

WH BKTh

1 2TB1

Earth

YE/

GN

F1

CNWO WH

13

5

MM

1

MM

BK

23

45

12

34

51

23

45

12

34

5

12

34

56

78

910

1112

1314

1516

1718

1920

BKBK

BKBK

BKBK

BKBK

BK

BLRD

BROR

WH

YE/

GN

RD

+12

+12

+12

3

Powe

r sou

rce lin

eSig

nal lin

e1

2

3

CNW3 WH1 3

WH BL

(2.0

A)(

3.15A

WHYE

/GN

PIS

WHWH

WHWH

WHWH

WHWH

WHWH

BLBL

BLBL

BLBL

BLBL

BLBL

RDRD

RDRD

RDRD

RDRD

RDRD

SW2

※1

BKBKBK

BKBK

RDWH

E1

Indoo

r unit

PCB

1 2

Optio

n

Remo

te oper

ation in

put(v

olt-fre

e cont

act)

The

line

betw

een

indoo

r unit

and

out

door

unit

[ ]

CNT

BL

HSBKBK

Remo

te op

eratio

n inp

ut(

volt-f

ree co

ntact)

Opera

tion ch

eck,dr

ain pu

mp m

otor te

st run

Temp

eratur

e sen

sor(

Remo

te co

ntrol)

Mode

l cap

acity

settin

gSW

6

Term

inal bl

ock(P

ower

source

)(□ ma

rk)TB

1TB

2

SW2

Remo

te co

ntrol

comm

unica

tion a

ddres

s

SW7-1

Thi-A

Thi-R

1,2,3

Th C

Term

inal b

lock(

Signa

l line)

( □ m

ark)

Temp

eratur

e sen

sor(

Retur

n air)

Temp

eratur

e sen

sor(

Heat

exch

ange

r)

Drain

pump

moto

r

Fan m

otor

DMFu

seF1

,2

Conn

ector

CNB-

Z

FMi

Desc

riptio

nIte

mDr

aft p

reve

ntion

func

tion

mot

orAM

1-4

Louv

er m

otor

Float

switc

h

LM1-

4

FS

Indica

tion l

amp(

Red-I

nspe

ction)

LED・

2Ind

icatio

n lam

p(Gr

een-N

omal

opera

tion)

LED・

3

LRe

actor

PISMo

tion s

enso

r

Humi

dity s

enso

rHS SW

5Plu

ral un

its Ma

ster/

Slave

settin

g

Color

mark

sMa

rkCo

lor

Blue

BK BLBr

own

Oran

geBR OR

Red

RD

Black

Mark

Color

Yello

wWH YE

Gray

Yellow

/Gree

nGY YE

/GN

White

Prep

are on

site

SW5

Page 85: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Thi-A

[ ]

Opera

tion ch

eck,dr

ain pu

mp m

otor te

st run

Tempe

rature

senso

r(Rem

ote co

ntrol)

Mode

l capa

city se

tting

SW6

Termin

al bloc

k(Pow

er sou

rce)(□

mark)

TB1

TB2

SW2

Remo

te con

trol co

mmun

ication

addre

ss

SW7-1

Thi-A

Thi-R

1,2,3

Thc

Termin

al bloc

k(Sign

al line)(□

mark)

Tempe

rature

senso

r(Retu

rn air)

Tempe

rature

senso

r(Hea

t exch

ange

r)

Drain p

ump m

otor

Fan m

otor

DMFu

seF1

,2

Conn

ector

CNB-Z

FMi

Descr

iption

Item

Draft p

reven

tion fu

nction

moto

rAM

1-4

Louve

r moto

r

Float

switch

LM1-4

FS

Indica

tion lam

p(Red

-Inspe

ction)

LED・2

Indica

tion lam

p(Gree

n-Nom

al ope

ration)

LED・3

PISMo

tion se

nsor

Humid

ity sen

sorHS SW

5Plu

ral un

its Ma

ster/

Slave

setting

Color

mark

s

Mean

ing of

mark

s

Mar

kCo

lor

Blue

BK BLBr

own

Oran

geBR OR

Red

RD

Black

Mar

kCo

lor

Yello

wWH YE

Gray

Yellow/G

reen

GY YE/G

N

White

CNTA BL

12

CNI

BL

CNJ1

WHCN

J2 GY

AM4

AM1

AM2

AM3

6 5 4 3 2 1

CNN

YE

Thi-R

3

Thi-R

2

Thi-R

1t°t°t°

2 1CN

CWH

CNH

BK

12

t°DM

12 CN

RWH

M

CNM1 WH

FMi M

F2

CNB

BK

12

34

56

78

910

1112

1314

1516

1718

1920

2 1

RD RDRDRDYEBKBK YE

14

56

7

FSX Y

X Yt°

TB2 WH BK

Thc

TB1

YE/G

N

12

34

56

78

910

1112

1314

1516

1718

1920

BLRD

BROR

WH

+12

+12

(2.0A)

YE/G

N

※1

BKBK

RDWH

LM4

LM1

LM2

LM3

MM

1

MM

23

45

12

34

51

23

45

12

34

5

MM

1

MM

BK

23

45

12

34

51

23

45

12

34

5

BKBK

BKBK

BKBK

BKBK

BK

WHWH

WHWH

WHWH

WHWH

WHWH

BLBL

BLBL

BLBL

BLBL

BLBL

RDRD

RDRD

RDRD

RDRD

RDRD

E1

F1

CNWO WH

13

5

YE/G

N

RD

(3.15

A)

WH Powe

r circ

uit

Indoo

r unit

PCB

CNL

BK3 12

BKBKBKOp

tion

1 2

(volt

-free c

ontac

t)

HSBKBK

Remo

te op

eratio

n inp

ut

BKBK

BKBK

BKBK

BKBK

BKBK

RDRD

RDRD

RDRD

RDRD

RDRD

CNJ3 WH

CNJ4 WH

WHWH

WHWH

WHWH

WHWH

WHWH

BLBL

BLBL

BLBL

BLBL

BLBL

1 2

Earth

3

Powe

r sou

rce lin

eSig

nal lin

e1

2

3

CNW3 WH1 3

WH BL

The l

ine be

twee

nind

oor u

nit an

d outd

oor u

nit

XR1

XR5

(Ope

ration)

(Hea

ting)

(Com

presso

r ON)

(Ins

pecti

on)

Prep

are on

site

XR2

XR3

XR4

1 2 3 4 5 6

+12

Remo

te op

eratio

n inp

ut(v

olt-fre

e con

tact)

CNT

BL

CNM2 WH

BLRD

BROR

WH

PIS3 12

Remo

te con

trol

SW2

SW6

SW7

LED・

3LE

D・2

Prep

are on

site

SW5

Note

s 1

.

in

dica

tes

wirin

g on

site

.  

2. S

ee th

e wi

ring

diag

ram

of o

utdo

or u

nit a

bout

the

line

betw

een

  

3. U

se tw

in c

ore

cord(

0.3m

m )

at re

mot

e co

ntro

l line

.2

ind

oor u

nit a

nd o

utdo

or u

nit.

  

4. D

o no

t put

rem

ote

cont

rol li

ne a

long

side

powe

r sou

rce

line.

  

5. D

raft

prev

entio

n fu

nctio

n(※1) i

s pr

ovid

ed o

n th

e pa

nel T

C-PS

AE-5

AW-E

onl

y.

(b) Ceiling casette-4 way compact type (FDTC)

Models FDTC50VH, 60VH

PJF000Z516 A

- 84 -

Page 86: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FMi1

FMi2

BL31

WHCN

W3 WH

RD RD

1 2CN

IBL

FS

CNZ

CNC

For H

A WH RD

RD

Contr

ol PC

B

RD YE

t°YE BK

t°BK

1 2 3 4 5 6

BK

t°BK

1 2

XR1

XR2

XR3

XR4

1 2 3 4 5 6

+12

SW2

SW6

SW5

SW7

LED・

2LE

D・3

X Y1 3

TB2

WH BK WH8 9 10 11 12

CNW2 WH

CNW1 WH

CNB

WHCN

NYE CN

HBK CN

TBL

1 2WHRD

YE/G

N

3 5

CNW0 WH

1

(Ope

ration)

(Hea

ting)

(Com

presso

r ON)

(Ins

pecti

on)

3

Thi-R

1

Thi-R

2

Thi-R

3

Thi-A

WH WH WH WHWH WH WH WHWH WH WH WH5 6 72 3 41

YE/G

NCN

RWH

1 2DM

MRD WH

+12

8 9 10 11 125 6 72 3 41

1

PISCN

GBL CN

V2 BK

24 3

1 3

WH BK RD

WH RD BK

Prep

are on

site

TB1

M

14

56

7

RD

F4 (2A)

CNM2 BK

Powe

r circ

uit BKWH

BLYE

L

CNWR WH

13

Powe

r PCB

※1

Earth

The l

ine be

twee

n

21 3

Powe

r sou

rce lin

eSig

nal lin

e

indoo

r unit

and o

utdoo

r unit

Optio

n

X Yt°Th

cRe

mote

contr

ol

M

14

56

7

RD

F3 (2A)

CNM1 WH

BKWH

BLYE

F1(6.3

A)

1 2CN

TA BL(R

emote

opera

tion

 inp

ut:vo

lt-free

conta

ct)

+12

Prep

are on

site

XR5(R

emote

opera

tion

input:

volt-f

ree co

ntact)

Thi-A

FMi1,

2FS

Float

switc

h

Indica

tion l

amp(R

ed-In

spec

tion)

Indica

tion l

amp(G

reen-N

ormal

opera

tion)

LED・

3LE

D・2

Conn

ector

CNB-Z

Mode

l cap

acity

settin

gSW

6Op

eratio

n che

ck,dr

ain pu

mp m

otor te

st run

SW7-1

SW5

Temp

eratur

e sen

sor(R

emote

contr

ol)

Temp

eratur

e sen

sor(H

eat e

xcha

nger)

Temp

eratur

e sen

sor(R

eturn

air)

Thc

Thi-R

1,2,3

TB2

Term

inal b

lock(S

ignal

line)(□m

ark)

TB1

Term

inal b

lock(P

ower

sourc

e)(□m

ark)

Remo

te co

ntrol

comm

unica

tion a

ddres

sSW

2Plu

ral un

its M

aster/S

lave s

etting

LRe

actor

F1,3,

4Fu

seFa

n moto

r

Drain

pump

moto

rDM

Motio

n sen

sor

PIS

Close

d-end

conn

ector

■mark

BKBla

ckBlu

e

Color

Mark

s

BLMark

Color

Red

RD WHYe

llow

White

Yello

w/Gr

een

YEYE/G

N

Item

Desc

riptio

nM

eanin

g of

mar

ks

Note

s 1

.

in

dica

tes

wirin

g on

site

.

2. S

ee th

e wi

ring

diag

ram

of o

utdo

or u

nit a

bout

the

line

betw

een

indo

or u

nit a

nd o

utdo

or u

nit.

3.

Use

twin

cor

e co

rd(0.

3mm

2)a

t rem

ote

cont

rol li

ne.

See

spec

she

et o

f rem

ote

cont

rol in

cas

e th

at th

e to

tal le

ngth

is m

ore

than

100

m.

4.

Do

not p

ut re

mot

e co

ntro

l line

alo

ngsid

e po

wer s

ourc

e lin

e.

5. S

ectio

n 1 (※

1)sh

ows

elec

tric

circu

it of

mot

ion

sens

or(O

ptio

n).

PJG000Z580

(c) Duct connected-High static pressure type (FDU)

Models FDU100VH, 125VH, 140VH

- 85 -

Page 87: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Note

s 1

.

in

dica

tes

wirin

g on

site

.

2. S

ee th

e wi

ring

diag

ram

of o

utdo

or u

nit a

bout

the

line

betw

een

indo

or u

nit a

nd o

utdo

or u

nit.

3.

Use

twin

cor

e co

rd(0.

3mm

2)a

t rem

ote

cont

rol li

ne.

See

spec

she

et o

f rem

ote

cont

rol in

cas

e th

at th

e to

tal le

ngth

is m

ore

than

100

m.

4.

Do

not p

ut re

mot

e co

ntro

l line

alo

ngsid

e po

wer s

ourc

e lin

e.

5. S

ectio

n 1(※

1)sh

ows

elec

tric

circu

it of

mot

ion

sens

or(O

ptio

n).FM

i1

RD RD

1 2CN

IBL

FS

CNZ

CNC

For H

A WH RD

RD

Contr

ol PC

B

RD YE

t°YE BK

t°BK

1 2 3 4 5 6

BK

t°BK

1 2

XR1

XR2

XR3

XR4

1 2 3 4 5 6

+12

SW2

SW6

SW5

SW7

LED・

2LE

D・3

X Y1 3

X Yt°

TB2

WH BK WH8 9 10 11 12

CNW2 WH

CNW1 WH

CNB

WHCN

NYE CN

HBK CN

TBL

(Ope

ration)

(Hea

ting)

(Com

presso

r ON)

(Ins

pecti

on)

Thc

Thi-R

1

Thi-R

2

Thi-R

3

Thi-A

WH WH WH WH

Remo

te co

ntrol

WH WH WH WHWH WH WH WH5 6 72 3 41

CNR

WH1 2

DMM

RD WH

+12

8 9 10 11 125 6 72 3 41

1

PISCN

GBL CN

V2 BK

24 3

1 3

Optio

n

WH BK RD

WH RD BK

Prep

are on

site

M

14

56

7

RD

F3 (2A)

CNM1 WH

Powe

r PCB

Powe

r circ

uit

BL or BK

BR or WH

WH or BL

OR or YE

※1

BL31

WHCN

W3 WH

1 2WHRD

YE/G

N

3 5

CNW0 WH

1

3

YE/G

NTB

1

F1(3.1

5A)

LCN

WR2

W

H BK

F2(3.1

5A)

Earth

The l

ine be

twee

n

21 3

Powe

r sou

rce lin

eSig

nal lin

e

indoo

r unit

and o

utdoo

r unit

1 2CN

TA BL(R

emote

opera

tion

 inp

ut:vo

lt-free

conta

ct)

+12

Prep

are on

site

XR5(R

emote

opera

tion

input:

volt-f

ree co

ntact)FM

i1FS

Float

switc

h

Indica

tion l

amp(R

ed-In

spec

tion)

Indica

tion l

amp(G

reen-N

ormal

opera

tion)

LED・

3LE

D・2

Conn

ector

CNB-Z

Mode

l cap

acity

settin

gSW

6Op

eratio

n che

ck,dr

ain pu

mp m

otor te

st run

SW7-1

SW5

Temp

eratur

e sen

sor (

Remo

te co

ntrol)

Temp

eratur

e sen

sor (

Heat

exch

ange

r)Te

mpera

ture s

enso

r (Re

turn a

ir)Th

c

Thi-R

1,2,3

Thi-A

TB2

Term

inal b

lock(S

ignal

line)(□m

ark)

TB1

Term

inal b

lock(P

ower

sourc

e)(□m

ark)

Remo

te co

ntrol

comm

unica

tion a

ddres

sSW

2Plu

ral un

its M

aster/S

lave s

etting

LRe

actor

F1-3

Fuse

Fan m

otor

Drain

pump

moto

rDM

Motio

n sen

sor

PIS

Close

d-end

conn

ector

■mark

BKBla

ckBlu

e

Color

Mark

s

BLMark

Color

BRBr

own

Oran

geOR

Red

RD WHYe

llow

White

Yello

w/Gr

een

YEYE/G

N

Item

Desc

riptio

nMe

aning

of m

arks

(d) Duct connected-Low / Middle static pressure type (FDUM)

Model FDUM50VH

PJG000Z488

- 86 -

Page 88: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Note

s 1

.

in

dica

tes

wirin

g on

site

.

2. S

ee th

e wi

ring

diag

ram

of o

utdo

or u

nit a

bout

the

line

betw

een

indo

or u

nit a

nd o

utdo

or u

nit.

3.

Use

twin

cor

e co

rd(0.

3mm

2)a

t rem

ote

cont

rol li

ne.

See

spec

she

et o

f rem

ote

cont

rol in

cas

e th

at th

e to

tal le

ngth

is m

ore

than

100

m.

4.

Do

not p

ut re

mot

e co

ntro

l line

alo

ngsid

e po

wer s

ourc

e lin

e.

5. S

ectio

n 1(※

1)sh

ows

elec

tric

circu

it of

mot

ion

sens

or(O

ptio

n).

FMi2

RD RD

1 2CN

IBL

FS

CNZ

CNC

For H

A WH RD

RD

Contr

ol PC

B

RD YE

t°YE BK

t°BK

1 2 3 4 5 6

BK

t°BK

1 2

XR1

XR2

XR3

XR4

1 2 3 4 5 6

+12

SW2

SW6

SW5

SW7

LED・

2LE

D・3

X Y1 3

X Yt°

TB2

WH BK WH8 9 10 11 12

CNW2 WH

CNW1 WH

CNB

WHCN

NYE CN

HBK CN

TBL

(Ope

ration)

(Hea

ting)

(Com

presso

r ON)

(Ins

pecti

on)

Thc

Thi-R

1

Thi-R

2

Thi-R

3

Thi-A

WH WH WH WH

Remo

te co

ntrol

WH WH WH WHWH WH WH WH5 6 72 3 41

CNR

WH1 2

DMM

RD WH

+12

8 9 10 11 125 6 72 3 41

1

PISCN

GBL CN

V2 BK

24 3

1 3

Optio

n

WH BK RD

WH RD BK

Prep

are on

site

Powe

r PCB

Powe

r circ

uit

※1

Earth

The l

ine be

twee

n

21 3

Powe

r sou

rce lin

eSig

nal lin

e

indoo

r unit

and o

utdoo

r unit

M

14

56

7

F4 (2A)

CNM2 BK

RDBL or BK

BR or WH

WH or BL

OR or YE

BL31

WHCN

W3 WH

1 2WHRD

YE/G

N

3 5

CNW0 WH

1

3 TB1

F1(5A)

YE/G

N

1 2CN

TA BL(R

emote

opera

tion

 inp

ut:vo

lt-free

conta

ct)

+12

Prep

are on

site

XR5(R

emote

opera

tion

input:

volt-f

ree co

ntact)FM

i2FS

Float

switc

h

Indica

tion l

amp(R

ed-In

spec

tion)

Indica

tion l

amp(G

reen-N

ormal

opera

tion)

LED・

3LE

D・2

Conn

ector

CNB-Z

Mode

l cap

acity

settin

gSW

6Op

eratio

n che

ck,dr

ain pu

mp m

otor te

st run

SW7-1

SW5

Temp

eratur

e sen

sor(R

emote

contr

ol)

Temp

eratur

e sen

sor(H

eat e

xcha

nger)

Temp

eratur

e sen

sor(R

eturn

air)

Thc

Thi-R

1,2,3

Thi-A

TB2

Term

inal b

lock(S

ignal

line)(□m

ark)

TB1

Term

inal b

lock(P

ower

sourc

e)(□m

ark)

Remo

te co

ntrol

comm

unica

tion a

ddres

sSW

2Plu

ral un

its M

aster/S

lave s

etting

F1,4

Fuse

Fan m

otor

Drain

pump

moto

rDM

Motio

n sen

sor

PIS

Close

d-end

conn

ector

■mark

BKBla

ckBlu

e

Color

Mark

s

BLMark

Color

BRBr

own

Oran

geOR

Red

RD WHYe

llow

White

Yello

w/Gr

een

YEYE/G

N

Item

Desc

riptio

nM

eanin

g of

mar

ks

Models FDUM60VH, 71VH

PJG000Z489

- 87 -

Page 89: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Note

s 1

.

in

dica

tes

wirin

g on

site

.

2. S

ee th

e wi

ring

diag

ram

of o

utdo

or u

nit a

bout

the

line

betw

een

indo

or u

nit a

nd o

utdo

or u

nit.

3.

Use

twin

cor

e co

rd(0.

3mm

2)a

t rem

ote

cont

rol li

ne.

See

spec

she

et o

f rem

ote

cont

rol in

cas

e th

at th

e to

tal le

ngth

is m

ore

than

100

m.

4.

Do

not p

ut re

mot

e co

ntro

l line

alo

ngsid

e po

wer s

ourc

e lin

e.

5. S

ectio

n 1(※

1)sh

ows

elec

tric

circu

it of

mot

ion

sens

or(O

ptio

n).

FMi1

FMi2

RD RD

1 2CN

IBL

FS

CNZ

CNC

For H

A WH RD

RD

Contr

ol PC

B

RD YE

t°YE BK

t°BK

1 2 3 4 5 6

BK

t°BK

1 2

XR1

XR2

XR3

XR4

1 2 3 4 5 6

+12

SW2

SW6

SW5

SW7

LED・

2LE

D・3

X Y1 3

X Yt°

TB2

WH BK WH8 9 10 11 12

CNW2 WH

CNW1 WH

CNB

WHCN

NYE CN

HBK CN

TBL

(Ope

ration)

(Hea

ting)

(Com

presso

r ON)

(Ins

pecti

on)

Thc

Thi-R

1

Thi-R

2

Thi-R

3

Thi-A

WH WH WH WH

Remo

te co

ntrol

WH WH WH WHWH WH WH WH5 6 72 3 41

CNR

WH1 2

DMM

RD WH

+12

8 9 10 11 125 6 72 3 41

1

PISCN

GBL CN

V2 BK

24 3

1 3

Optio

n

WH BK RD

WH RD BK

Prep

are on

site

Powe

r PCB

Powe

r circ

uit

※1

Earth

The l

ine be

twee

n

21 3

Powe

r sou

rce lin

eSig

nal lin

e

indoo

r unit

and o

utdoo

r unit

M

14

56

7

F4 (2A)

CNM2 BK

RDBL or BK

BR or WH

WH or BL

OR or YE

BL31

WHCN

W3 WH

1 2WHRD

YE/G

N

3 5

CNW0 WH

1

3 TB1

F1(5A)

YE/G

N

M

14

56

7

RD

F3 (2A)

CNM1 WH

BL or BK

BR or WH

WH or BL

OR or YEL

CNWR WH

13

1 2CN

TA BL(R

emote

opera

tion

 inp

ut:vo

lt-free

conta

ct)

+12

Prep

are on

site

XR5(R

emote

opera

tion

input:

volt-f

ree co

ntact)Th

i-R1,2

,3

FMi1,

2FS

Float

switc

h

Indica

tion l

amp(R

ed-In

spec

tion)

Indica

tion l

amp(G

reen-N

ormal

opera

tion)

LED・

3LE

D・2

Conn

ector

CNB-Z

Mode

l cap

acity

settin

gSW

6Op

eratio

n che

ck,dr

ain pu

mp m

otor te

st run

SW7-1

SW5

Temp

eratur

e sen

sor(R

emote

contr

ol)

Temp

eratur

e sen

sor(H

eat e

xcha

nger)

Temp

eratur

e sen

sor(R

eturn

air)

Thc

Thi-A

TB2

Term

inal b

lock(S

ignal

line)(□m

ark)

TB1

Term

inal b

lock(P

ower

sourc

e)(□m

ark)

Remo

te co

ntrol

comm

unica

tion a

ddres

sSW

2Plu

ral un

its M

aster/S

lave s

etting

LRe

actor

F1,3,

4Fu

seFa

n moto

r

Drain

pump

moto

rDM

Motio

n sen

sor

PIS

Close

d-end

conn

ector

■mark

BKBla

ckBlu

e

Color

Mark

s

BLMark

Color

BRBr

own

Oran

geOR

Red

RD WHYe

llow

White

Yello

w/Gr

een

YEYE/G

N

Item

Desc

riptio

nM

eanin

g of

mar

ks

Models FDUM100VH, 125VH, 140VH

PJG000Z490

- 88 -

Page 90: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

(e) Ceiling suspended type (FDE)

Models FDE50VH, 60VH, 71VH, 100VH, 125VH, 140VH

PFA004Z087

- 89 -

Powe

r PCB

1 2 3 4 5CN

W1 WH

F1(3.1

5A)

3 5CNW0 WH

1

Powe

r circ

uit6 7 8 9 10 11 12

WHRD1 2 TB

1Ea

rth

M

14

56

7

F3(2

.0A) R D

B KW H

Y EB L

FMi

CNM1 WH

YE/G

N

3

BLWH1 3

CNW3 WHF2(

3.15A)

Mark BK BL BR OR

Color

Black

Blue

Brow

nOr

ange

RD WHRe

dWh

iteYe

llow

Yello

w/Gr

een

Pink

The l

ine be

twee

n

21 3

Powe

r sou

rce lin

eSig

nal lin

e

indoo

r unit

and o

utdoo

r unit

YE/G

N

PK YEYE/G

N

14

56

7

R DB K

W HY E

B LCN

F1WH

RD

WHRD

1 2CN

IBL

RD

Contr

ol PC

B

t°YE YE BK

t°6

BK

1 2 3 4 5

BK

t°BK

1 2

XR1

XR2

XR3

XR4

XR5(R

emote

opera

tion

Prep

are on

site

1 2 3 4 5 6

+12

X Y1 3

X Yt°

TB2

WH BK

CNW2 WHCNB

WHCN

NYE CN

HBK CN

TBL

(Ope

ration)

(Hea

ting)

(Com

presso

r ON)

(Ins

pecti

on)

Thc

Thi-R

1

Thi-R

2

Thi-R

3

Thi-A

Remo

te co

ntrol

input:

volt-f

ree co

ntact)

1 2CN

TA BL(R

emote

opera

tion

 inp

ut:vo

lt-free

conta

ct)

8 9 10 11 125 6 72 3 41WH WH WH WH WH WH WH WH WH WH WH WH

M

1 2 3 4 5

1 2 3 4 5

LM

6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

CNJ

WH

BL PK BR OR RD

+12

1

PISCN

GBL CN

V2 BK

24 3

1 3

Optio

n

WH BK RD

WH RD BK

WH RD BK

WH RD BK

CNL1

WHCN

L2 WH

Prep

are on

site

CNZ

CNC

For H

A WH RD

SW2

SW6

SW5

SW7

LED・

2LE

D・3

SW8

※1

5.

Sec

tion

1(※

1)sh

ows

elec

tric

circu

it of

mot

ion

sens

or(O

ptio

n).

Note

s 1

.

in

dica

tes

wirin

g on

site

.

2. S

ee th

e wi

ring

diag

ram

of o

utdo

or u

nit a

bout

the

line

betw

een

indo

or u

nit a

nd o

utdo

or u

nit.

3.

Use

twin

cor

e co

rd(0.

3mm

2)a

t rem

ote

cont

rol li

ne.

See

spec

she

et o

f rem

ote

cont

rol in

cas

e th

at th

e to

tal le

ngth

is m

ore

than

100

m.

4.

Do

not p

ut re

mot

e co

ntro

l line

alo

ngsid

e po

wer s

ourc

e lin

e.

Opera

tion c

heck

,drain

pump

moto

r test

run

Color

mark

s

Indica

tion l

amp(R

ed-In

spec

tion)

Indica

tion l

amp(G

reen-N

ormal

opera

tion)

LED・

3LE

D・2

Conn

ector

CNB-Z

Mode

l cap

acity

settin

gSW

6SW

7-1

SW5

L

Tempe

rature

senso

r(Rem

ote co

ntrol)

Tempe

rature

senso

r(Hea

t exc

hang

er)

Thc

Tempe

rature

senso

r(Retu

rn air)

Thi-R

1,2,3

Thi-A

TB2

Term

inal b

lock(S

ignal

line)(□m

ark)

TB1

Term

inal b

lock(P

ower

sourc

e)(□m

ark)

LM

Remo

te co

ntrol

comm

unica

tion a

ddres

sSW

2Plu

ral un

its M

aster/S

lave s

etting

Reac

tor

F1-3

Fuse

FMi

Louv

er mo

tor

Fan m

otor

Motio

n sen

sor

PIS

Item

Desc

riptio

n

Anti-f

reeze

contr

olSW

8-1

Mean

ing of

mark

s

Page 91: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

(f) Wall mounted type (SRK)

Models SRK50ZSX-W, 60ZSX-W

RWA000Z413

- 90 -

F3.1

5AFU

SE

G2

L250

V

S/N

VARI

STOR

CNU

CNS

INTE

RFAC

E KI

T

CNG

CNE

DISPL

AYWI

RELE

SS RE

CEIVE

R

JCNF

U

M1 3 4 5 6

BACK

-UP S

W

52

L

BOAR

DCI

RCUI

TPR

INTE

DCN

LM M M M

5 5

RED

WHI

TE

RED

WHI

TEBL

ACK

BLUE

YELL

OW

YELL

OW/

GREE

N

BLAC

K

t t t

POW

ER C

ABLE

SIGN

AL W

IRE

M

5 5 5

M5

M5

LEFT

MOT

ORLO

UVER

RIGH

TM

OTOR

LOUV

ER

RIGH

TLO

WER

MOT

ORFL

AP

UPPE

RM

OTOR

FLAP

LEFT

MOT

ORIN

LET

RIGH

TM

OTOR

INLE

T

SWLIM

ITPA

NEL

INLE

T MOT

ORFA

N

STAC

KDI

ODE

13

EXCH

ANGE

RHE

AT

EXCH

ANGE

RHE

AT

Powe

r sou

rce

1 Ph

ase

220-

240V

50H

z22

0V 6

0Hz

TO O

UTDO

OR U

NIT

CNJ

3

SENS

ORRO

OM T

EMP.

SENS

OR 1

HEAT

EXC

HANG

ER

SENS

OR 2

HEAT

EXC

HANG

ER

SENS

ORHU

MID

ITY

SENS

ORM

OTIO

N

31

[

]

CNZ

CNX

CNY

CNM

CNP

Desc

riptio

nIte

mCo

nnec

tor

CNE

CNF

CNG

CNJ

CNL

CNM

CNP

CNS

CNU

CNX

CNY

CNZ

LEFT

LOW

ERM

OTOR

FLAP

7

YELL

OW/

GREE

N

BLOC

KTE

RMIN

AL

EART

H W

IRE

T2

N2

N

4

Page 92: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Models SRK71ZR-W, 100ZR-W

RWA000Z417A

- 91 -

tototo

TO O

UTDO

OR

UNIT

POW

ER C

ABLE

SIG

NAL

WIR

E

EART

H W

IRE

12/

N

3

POW

ER S

OUR

CE1

Phas

e 22

0-24

0V 5

0Hz

22

0V 6

0Hz

F 3.

15A

F

G S/N

Va

FMi

CNU

CNS

INTE

RFAC

E KIT

J

U

MHE

AT

1 3 4 5 6

5

TB 1 2/N 3

EXCH

ANGE

RL

HEAT

EXCH

ANGE

R

BOAR

DCI

RCUI

TPR

INTE

D

SM1

LM1

CNX

M M M

5 5LM

2

RDWH

RD WH

BK BLY

Y/G BK

CNG

CNE

DISP

LAY

WIRE

LESS

RECE

IVER

CNF

BACK

-UP

SW

28

Th21

Th22

Th1

Th3

CNY

Y/G

CNM

5

Colo

r Mar

ks

Blue

Blac

kBK

Red

BL RDW

hite

WH

Yello

w/G

reen

Y/G

Yello

wY

Colo

rM

ark

Heat

exch

ange

r temp

eratur

e sen

sor

Hum

idity

sen

sor

Fan

mot

or

Room

tem

pera

ture

sen

sor

Flap

mot

or

Th1

Th21

,2

Th3

Diod

e st

ack

DSFu

seF

Conn

ecto

rCN

E

FMi

Term

inal

blo

ckTB

Louv

er m

otor

LM1,

2

SM1

Desc

riptio

nIte

m

Varis

tor

VaCNF

CNG

CNM

CNS

CNU

CNX

CNY

L 250

V

DS

Page 93: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

(2) Outdoor units

Models FDC100VNA-W, 125VNA-W, 140VNA-W

PCA001Z854

SW3-

3,4

SW3-

2

SW3-

1

Loca

l set

ting

switc

h SW

3,5,

7(Se

t up

at s

hipm

ent O

FF)

100

Mode

l

Powe

r cab

le, i

ndoo

r-out

door

con

nect

ing

wire

s

125

2422

φ1.

6mm

x 3

φ1.

6

100

Mode

l

※At

the

conn

ectio

n wi

th th

e du

ct ty

pe in

door

uni

t.

125

2620

φ1.

6mm

x 3

φ1.

6

The

spec

ificat

ions

sho

wn in

the

abov

e ta

ble

are

for u

nits

with

out h

eate

rs. F

or u

nits

with

hea

ters

, ref

erto

the

inst

alla

tion

inst

ruct

ions

or t

he c

onst

ruct

ion

inst

ruct

ions

of t

he in

door

uni

t.Sw

itchg

ear o

f circ

uit b

reak

er c

apac

ity w

hich

is c

alcu

late

d fro

m M

AX. o

ver c

urre

nt s

houl

d be

cho

sen

alon

g th

e re

gula

tions

in e

ach

coun

try.

The

cabl

e sp

ecific

atio

ns a

re b

ased

on

the

assu

mpt

ion

that

a m

etal

or p

last

ic co

ndui

t is

used

with

no

mor

e th

an th

ree

cabl

es c

onta

ined

in a

con

duit

and

a vo

ltage

dro

p is

2%. F

or a

n in

stal

latio

n fa

lling

outs

ide

of th

ese

cond

itions

, ple

ase

follo

w th

e in

tern

al c

ablin

g re

gula

tions

. Ada

pt it

to th

e re

gula

tion

in e

ffect

in e

ach

coun

try.

140

140

27

5.5

5.5

SW5-

2

SW7-

2

SW7-

3

Snow

gua

rd fa

n co

ntro

l

Defro

st co

ntro

l cha

nge

Trial

ope

ratio

n

wher

e ou

tside

tem

pera

ture

bec

omes

belo

w

21 3 op

erat

ion is

finish

ed.

4 SW

3-3

is ON

.

Met

hod

of tr

ial o

pera

tion

Be su

re to

turn

OFF

SW

3-3

afte

r the

trial

op

erat

ion w

hen

SW3-

4 is

ON

Cooli

ng tr

ial o

pera

tion

will b

e pe

rform

ed

Com

pres

sor w

ill be

in th

e op

erat

ion w

hen

Trial

ope

ratio

n ca

n be

per

form

ed b

y usin

g

runn

ing w

hen

the

unit i

s use

d in

a ve

ry

3°C

or lo

wer a

nd th

e co

mpr

esso

r is n

ot

minu

tes,

when

out

door

tem

pera

ture

falls

toun

it fan

will

run

for 3

0 se

cond

s in

ever

y 10

Whe

n th

is sw

itch

is tu

rned

ON,

the

outd

oor

This

switc

h sh

ould

be tu

rned

ON

in th

e ar

ea

shor

ter b

y tur

ning

ON th

is sw

itch.

Th

e de

frost

oper

ation

inte

rval

beco

mes

MAX

ove

r cur

rent

Powe

r cab

le s

ize(

mm

)2(

A)Po

wer c

able

lengt

h(

m)

indoo

r-out

door

wire

size

x nu

mbe

r Ea

rth w

ire s

ize(

mm)

MAX

ove

r cur

rent

Powe

r cab

le s

ize(

mm

)2(

A)Po

wer c

able

lengt

h(

m)

indoo

r-out

door

wire

size

x nu

mbe

r Ea

rth w

ire s

ize(

mm)

the

freez

ing p

oint.

snow

y cou

ntry,

set t

his sw

itch

to O

N.

SW3-

3,4.

wh

en S

W3-

4 is

OFF,

and

heat

ing tr

ial

High

heig

ht d

iffere

nce

unit b

y 30m

or m

ore.

insta

lled

at a

pos

ition

highe

r tha

n ind

oor

Set t

his sw

itch

to O

N wh

en o

utdo

or u

nit is

op

erat

ion co

ntro

l

exte

rnal

equip

men

t.op

erat

ion b

y rem

ote

cont

rol c

onne

cted

Set t

his sw

itch

to O

N wh

en m

anag

ing u

nit

Defro

st co

ntro

l cha

nge

spee

d be

com

es lo

wer i

n sil

ent m

ode.

Uppe

r lim

it of c

ompr

esso

r spe

ed a

nd fa

n Lo

wer n

oise

silen

t mod

e

Pow

erso

urce

1P

hase

220-

240V

50Hz

/ 22

0V

60Hz

Cran

kcas

e hea

ter

Mea

ning

of m

arks

Col

or m

arks

CHIte

mDe

scrip

tion

Comp

ress

or m

otor

CMCo

nnec

torCN

Curre

nt se

nsor

CT

1Dr

ain pa

n hea

terDH

Expa

nsion

valve

for c

oolin

gEE

VCEx

pans

ion va

lve fo

r hea

ting

EEVH

Intell

igent

powe

r mod

ule

FFa

n moto

rFM

1IP

MInd

icatio

n lam

p(GR

EEN)

LED1

Indica

tion l

amp(

RED)

LED2

Reac

torL1

,2

Switc

hSW

1SW

3,5,7

Loca

l sett

ing sw

itch

Term

inal b

lock

TBTe

mper

ature

sens

or(Ou

tdoor

air)

THo-

ATe

mper

ature

seso

r(Disc

harg

e pipe)

THo-

D

Temp

eratu

re se

nsor(

Sucti

on pi

pe)

THo-

R1,R

2

Solen

oid va

lve fo

r 4-w

ay va

lveAu

xillia

ry re

lay

THo-

S

Auxil

liary

relay

20S

Auxil

liary

relay(

for 20

S)

52X1

Auxil

liary

relay(

for C

H)

52X3

High

pres

sure

switc

h63

H1

Y/GN

Yello

w/Gr

een

YYe

llow

WH

Whit

eRD

Red

OROr

ange

GNGr

een

BRBr

own

BLBl

ueBK

Blac

kMa

rkCo

lor

52X1

152

X14

52X1

5Au

xillia

ry re

lay(for

DH)

Temp

eratu

re se

nsor(

Heat

exch

ange

r)

Fuse

IPM

T12

T22L2

CNP

(WH)

CNEE

V1(W

H)CN

EEV2

(RD)

CNFA

N1(W

H)

CNF

(BK)

CNR

( WH)

CNS

(RD)

CNH

(BR)

CNTH

(WH)

CNB

(RD)

LED1

LED2

SW5

SW1

52X3

52X1

5

52X1RD

RD

BLOR

WH

RD

BLOR

WH

WHORBRBLRD

64

32

16

43

21

76

54

1

BR

BR

BR

BR

BK

BK

BKBK

BKBK

RDRD

YY

BKBK

CH20

S

63H1

Tho-

R1Th

o-D

Tho-

STh

o-A

Tho-

R2

PCB1

RD WH

L NNO

ISE

FILT

ERPC

B2

23

41

MM

MEE

VCEE

VHFM

1

TB

t°t°

t°t°

TB9

TB8

TB7

U VW

BLWH

RD

CNW

2(O

R)

WH

BL

WH

WH

DH

Optio

n

Y

Y

52X1

1

52X1

4

SW3

SW7

23

41

23

1

(2A)

CM

WH

WH

RD

WH

TB5

TB6

RD

TB4

TB3

1 2 3

TO I

NDOO

R UN

ITPO

WER

CAB

LE 1

2SI

GNAL

WIR

E 3

TB7

TB8

Y/GN

TB

WH

RD

GN

MCCB

ELCB

GN

CN1

(WH)

CT1

TB1

TB2

T1Y/

GN

L1PW

B7

Y/GN

E

CN1

MS

3~

F (2A)

F (3.15

A)

F

(8A)

F(3

0A)

F

CNPS

L(

WH)

BK

RD

PSLWH

Low

pres

sure

sens

orPS

L

- 92 -

Page 94: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Models FDC100VSA-W, 125VSA-W, 140VSA-W

PCA001Z855

Powe

r sou

rce 3P

hase

380ー4

15V 5

0Hz

100

Mode

l

Powe

r cab

le, i

ndoo

r-out

door

con

nect

ing

wire

s

125

153.

546

φ1.

6mm

x 3

φ1.

6

100

Mode

l

※At

the

conn

ectio

n wi

th th

e du

ct ty

pe in

door

uni

t.

125

1740

φ1.

6mm

x 3

The

spec

ificat

ions

sho

wn in

the

abov

e ta

ble

are

for u

nits

with

out h

eate

rs. F

or u

nits

with

hea

ters

, ref

erto

the

inst

alla

tion

inst

ruct

ions

or t

he c

onst

ruct

ion

inst

ruct

ions

of t

he in

door

uni

t.Sw

itchg

ear o

f circ

uit b

reak

er c

apac

ity w

hich

is c

alcu

late

d fro

m M

AX. o

ver c

urre

nt s

houl

d be

cho

sen

alon

g th

e re

gula

tions

in e

ach

coun

try.

The

cabl

e sp

ecific

atio

ns a

re b

ased

on

the

assu

mpt

ion

that

a m

etal

or p

last

ic co

ndui

t is

used

with

no

mor

e th

an th

ree

cabl

es c

onta

ined

in a

con

duit

and

a vo

ltage

dro

p is

2%. F

or a

n in

stal

latio

n fa

lling

outs

ide

of th

ese

cond

itions

, ple

ase

follo

w th

e in

tern

al c

ablin

g re

gula

tions

. Ada

pt it

to th

e re

gula

tion

in e

ffect

in e

ach

coun

try.

140

140

1838

3.5

φ1.

6

SW3-

3,4

SW3-

2

SW3-

1

Loca

l set

ting

switc

h SW

3,5,

7(Se

t up

at s

hipm

ent O

FF)

SW5-

2

SW7-

2

SW7-

3

Mea

ning

of m

arks

Col

or m

arks

MAX

ove

r cur

rent

Powe

r cab

le s

ize(

mm

)2(

A)Po

wer c

able

lengt

h(

m)

indoo

r-out

door

wire

size

x nu

mbe

r Ea

rth w

ire s

ize(

mm)

MAX

ove

r cur

rent

Powe

r cab

le s

ize(

mm

)2(

A)Po

wer c

able

lengt

h(

m)

indoo

r-out

door

wire

size

x nu

mbe

r Ea

rth w

ire s

ize(

mm)

Snow

gua

rd fa

n co

ntro

l

Defro

st co

ntro

l cha

nge

Trial

ope

ratio

n

wher

e ou

tside

tem

pera

ture

bec

omes

belo

w

21 3 op

erat

ion is

finish

ed.

4 SW

3-3

is ON

.

Met

hod

of tr

ial o

pera

tion

Be su

re to

turn

OFF

SW

3-3

afte

r the

trial

op

erat

ion w

hen

SW3-

4 is

ON

Cooli

ng tr

ial o

pera

tion

will b

e pe

rform

ed

Com

pres

sor w

ill be

in th

e op

erat

ion w

hen

Trial

ope

ratio

n ca

n be

per

form

ed b

y usin

g

runn

ing w

hen

the

unit i

s use

d in

a ve

ry

3°C

or lo

wer a

nd th

e co

mpr

esso

r is n

ot

minu

tes,

when

out

door

tem

pera

ture

falls

toun

it fan

will

run

for 3

0 se

cond

s in

ever

y 10

Whe

n th

is sw

itch

is tu

rned

ON,

the

outd

oor

This

switc

h sh

ould

be tu

rned

ON

in th

e ar

ea

shor

ter b

y tur

ning

ON th

is sw

itch.

Th

e de

frost

oper

ation

inte

rval

beco

mes

the

freez

ing p

oint.

snow

y cou

ntry,

set t

his sw

itch

to O

N.

SW3-

3,4.

wh

en S

W3-

4 is

OFF,

and

heat

ing tr

ial

High

heig

ht d

iffere

nce

unit b

y 30m

or m

ore.

insta

lled

at a

pos

ition

highe

r tha

n ind

oor

Set t

his sw

itch

to O

N wh

en o

utdo

or u

nit is

op

erat

ion co

ntro

l

exte

rnal

equip

men

t.op

erat

ion b

y rem

ote

cont

rol c

onne

cted

Set t

his sw

itch

to O

N wh

en m

anag

ing u

nit

Defro

st co

ntro

l cha

nge

spee

d be

com

es lo

wer i

n sil

ent m

ode.

Uppe

r lim

it of c

ompr

esso

r spe

ed a

nd fa

n Lo

wer n

oise

silen

t mod

e

IPM

T11

T12

L

CNW

3(

WH)

CNEE

V1(

WH)

CNEE

V2(

RD)

CNFA

N1(

WH)

LED1

LED2

SW5

SW1

52X2

52X1

5

52X1

BK

WH

RD

BLOR

WH

RD

BLOR

WH

WHORBRBLRD

64

32

16

43

21

76

54

1

PCB1

RD WH

TB7

L1 N

NOIS

E FI

LTER

PCB2

23

41

MM

M

EEVC

EEVH

FM1

TB

TB9

TB8

TB7

U VW

BLWH

RD

CNW

2(

OR)

CNW

1(

Y)

BK

RD

Y

Y

52X1

1

52X1

452

X6

SW3

SW7

23

41

23

1CM

Y

WH

TB3

TB2

TB1

RD

WH

BLTB

8BK

TB9

TB6

RD

TB2

TB3

TB4

TB1

1 2 3

TO I

NDOO

R UN

ITPO

WER

CAB

LE 1

2SI

GNAL

WIR

E 3

T12

TB5

L2 L3BL BK Y/

GN

BL

TBRD

BK

BK

Y/GN

GN

MCCB

ELCB

MS

3~

(10

A)F

(2A)

F (2A)

F (2A)

F

CNF

(BK)

CNR

(W

H)CN

S(

RD)

CNH

(BR)

CNTH

(W

H)CN

B(

RD)

BR

BR

BR

BR

BK

BK

BKBK

BKBK

RDRD

YY

BKBK

CH20

S

63H1

Tho-

R1Th

o-D

Tho-

STh

o-A

Tho-

R2

t°t°

t°t°

WH

WH

DH

Optio

n

Cran

kcas

e hea

terCH

Item

Desc

riptio

n

Comp

ress

or m

otor

CMCo

nnec

torCN

Drain

pan h

eater

DHEx

pans

ion va

lve fo

r coo

ling

EEVC

Expa

nsion

valve

for h

eatin

gEE

VH

Intell

igent

powe

r mod

ule

FFa

n moto

rFM

1IP

M

Indica

tion l

amp(

GREE

N)LE

D1Ind

icatio

n lam

p(RE

D)LE

D2

Switc

h SW

1 SW

3,5,7

Loca

l sett

ing sw

itch

Term

inal b

lock

TBTe

mper

ature

sens

or(Ou

tdoor

air)

THo-

ATe

mper

ature

sens

or(Di

scha

rge p

ipe)

THo-

D

Temp

eratu

re se

nsor(

Sucti

on pi

pe)

THo-

R1,R

2

Solen

oid va

lve fo

r 4-w

ay va

lveAu

xillia

ry re

lay

THo-

S

Auxil

liary

relay

20S

Auxil

liary

relay(

for 20

S)

52X1

Auxil

liary

relay(

for C

H)

52X2

High

pres

sure

switc

h63

H1

52X1

152

X14

52X1

5Au

xillia

ry re

lay(for

DH)

Temp

eratu

re se

nsor(

Heat

exch

ange

r)

Fuse

Reac

torL

Auxil

iary r

elay (

for F

M1)

52X6

Y/GN

Yello

w/Gr

een

YYe

llow

WH

Whit

eRD

Red

OROr

ange

GNGr

een

BRBr

own

BLBl

ueBK

Blac

kMa

rkCo

lor

CNPS

L(

WH)

BK

RD

PSLWH

Low

pres

sure

sens

orPS

L

- 93 -

Page 95: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D1.4 TECHNICAL INFORMATION

(1) Ceiling cassette-4 way type (FDT)

FDT100VNAWVH

- 94 -

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDT100VH information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 7.13 A++heating / Average Pdesignh 8.50 kW heating / Average SCOP/A 4.60 A++heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.50 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.66 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.71 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 9.24 -Tj=20℃ Pdc 3.10 kW Tj=20℃ EERd 11.64 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.26 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.43 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.78 -Tj=12℃ Pdh 2.90 kW Tj=12℃ COPd 7.19 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.96 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.25 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 7 W cooling Qce 491 kWh/astandby mode Psb 7 W heating / Average Qhe 2590 kWh/athermostat-off mode Pto(cooling) 22 W heating / Warmer Qhe - kWh/a

Pto(heating) 34 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 62 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 2220 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex,UB11 1ET, United kingdom

PJF000Z589 B

Page 96: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT100VSAWVH

- 95 -

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDT100VH information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 7.13 A++heating / Average Pdesignh 8.50 kW heating / Average SCOP/A 4.60 A++heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.50 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.66 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.71 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 9.24 -Tj=20℃ Pdc 3.10 kW Tj=20℃ EERd 11.64 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.26 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.43 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.78 -Tj=12℃ Pdh 2.90 kW Tj=12℃ COPd 7.19 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.96 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.25 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 7 W cooling Qce 491 kWh/astandby mode Psb 7 W heating / Average Qhe 2590 kWh/athermostat-off mode Pto(cooling) 22 W heating / Warmer Qhe - kWh/a

Pto(heating) 34 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 62 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675staged No Rated air flow(indoor) - 2220variable Yes Rated air flow(outdoor) - 4500

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex,UB11 1ET, United kingdom

kgCO2eq.m3/hm3/h

PJF000Z589 B

Page 97: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT100VNAWPVH

- 96 -

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDT50VH (x2 units) information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 7.41 A++heating / Average Pdesignh 8.50 kW heating / Average SCOP/A 4.47 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.50 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.55 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.60 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 9.60 -Tj=20℃ Pdc 3.49 kW Tj=20℃ EERd 15.30 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.05 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.15 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 6.10 -Tj=12℃ Pdh 2.82 kW Tj=12℃ COPd 7.60 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.70 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.25 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 10 W cooling Qce 473 kWh/astandby mode Psb 10 W heating / Average Qhe 2665 kWh/athermostat-off mode Pto(cooling) 15 W heating / Warmer Qhe - kWh/a

Pto(heating) 30 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 62 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675staged No Rated air flow(indoor) - 1200variable Yes Rated air flow(outdoor) - 4500

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex,UB11 1ET, United kingdom

kgCO2eq.m3/hm3/h

PJF000Z589 B

Page 98: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT100VSAWPVH

- 97 -

kgCO2eq.m3/hm3/h

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDT50VH (x2 units) information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 7.41 A++heating / Average Pdesignh 8.50 kW heating / Average SCOP/A 4.47 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.50 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.55 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.60 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 9.60 -Tj=20℃ Pdc 3.49 kW Tj=20℃ EERd 15.30 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.05 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.15 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 6.10 -Tj=12℃ Pdh 2.82 kW Tj=12℃ COPd 7.60 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.70 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.25 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 10 W cooling Qce 473 kWh/astandby mode Psb 10 W heating / Average Qhe 2665 kWh/athermostat-off mode Pto(cooling) 15 W heating / Warmer Qhe - kWh/a

Pto(heating) 30 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 62 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675staged No Rated air flow(indoor) - 1200variable Yes Rated air flow(outdoor) - 4500

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex,UB11 1ET, United kingdom

PJF000Z589 B

Page 99: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT125VNAWVH

- 98 -

Model(s) : FDC125VNA-W / FDT125VHOutdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.8 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.007 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.022 kW Standby mode PSB 0.007 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

309.0 %

Prated,c 12.5 kW 258.0 %

m3/h

486.0 %

773.0 %

Contact details

LWA 71.0 dB

NOx*** -

675

1164.0 %

0.25

4500

kgCO2eq.

PJF000Z589 B

Page 100: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 99 -

Information to identify the model(s) to which the information relates : FDC125VNA-W / FDT125VHOutdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 2.9 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.007 kW

Thermostat-off mode PTO 0.034 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%172.1

No

Prated,h 14.0 kW

300.0 %

425.0 %

545.0 %

719.0 %

0.25

270.0 %

220.0 %

- %

- �

- kW

m3/h

LWA 71.0 dB- m3/h

PSB 0.007 kW

elbu

NOx*** -

675

Contact details

4380

kgCO2eq.

PJF000Z589 B

Page 101: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT125VSAWVH

- 100 -

Model(s) : FDC125VSA-W / FDT125VHOutdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.8 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.007 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.022 kW Standby mode PSB 0.007 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

309.0 %

Prated,c 12.5 kW 258.0 %

m3/h

486.0 %

773.0 %

Contact details

LWA 71.0 dB

NOx*** -

675

1164.0 %

0.25

4500

kgCO2eq.

PJF000Z589 B

Page 102: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 101 -

Information to identify the model(s) to which the information relates : FDC125VSA-W / FDT125VHOutdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 2.9 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.007 kW

Thermostat-off mode PTO 0.034 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%172.1

No

Prated,h 14.0 kW

300.0 %

425.0 %

545.0 %

719.0 %

0.25

270.0 %

220.0 %

- %

- ℃

- kW

m3/h

LWA 71.0 dB- m3/h

PSB 0.007 kW

elbu

NOx*** -

675

Contact details

4380

kgCO2eq.

PJF000Z589 B

Page 103: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT140VNAWVH

- 102 -

Model(s) : FDC140VNA-W / FDT140VHOutdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.007 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.022 kW Standby mode PSB 0.007 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

284.0 %

Prated,c 13.6 kW 243.6 %

m3/h

443.0 %

717.0 %

Contact details

LWA 72.0 dB

NOx*** -

675

1164.0 %

0.25

4500

kgCO2eq.

PJF000Z589 B

Page 104: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 103 -

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDT140VHOutdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.0 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.7 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 2.9 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.007 kW

Thermostat-off mode PTO 0.034 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%173.9

No

Prated,h 15.5 kW

305.0 %

430.0 %

550.0 %

719.0 %

0.25

250.0 %

210.0 %

- %

- ℃

- kW

m3/h

LWA 73.0 dB- m3/h

PSB 0.007 kW

elbu

NOx*** -

675

Contact details

4380

kgCO2eq.

PJF000Z589 B

Page 105: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT140VSAWVH

- 104 -

Model(s) : FDC140VSA-W / FDT140VHOutdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.007 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.022 kW Standby mode PSB 0.007 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

284.0 %

Prated,c 13.6 kW 243.6 %

m3/h

443.0 %

717.0 %

Contact details

LWA 72.0 dB

NOx*** -

675

1164.0 %

0.25

4500

kgCO2eq.

PJF000Z589 B

Page 106: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 105 -

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDT140VHOutdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.0 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.7 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 2.9 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.007 kW

Thermostat-off mode PTO 0.034 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%173.9

No

Prated,h 15.5 kW

305.0 %

430.0 %

550.0 %

719.0 %

0.25

250.0 %

210.0 %

- %

- ℃

- kW

m3/h

LWA 73.0 dB- m3/h

PSB 0.007 kW

elbu

NOx*** -

675

Contact details

4380

kgCO2eq.

PJF000Z589 B

Page 107: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT125VNAWPVH

- 106 -

Model(s) : FDC125VNA-W / FDT60VH (x2 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.6 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

0.25

4500 m3/h

Contact details

LWA 71.0 dB

NOx*** -

675

Prated,c 12.5 kW 315.5 %

330.0 %

519.0 %

950.0 %

1960.0 %

kgCO2eq.

PJF000Z589 B

Page 108: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 107 -

Information to identify the model(s) to which the information relates : FDC125VNA-W / FDT60VH (x2 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%205.1

No

Prated,h 14.0 kW

662.0 %

985.0 %

328.0 %

508.0 %

0.25

270.0 %

220.0 %

- %

- ℃

NOx*** -

675

Contact details

4380

- kW

m3/h

LWA 71.0 dB- m3/h

PSB 0.008 kW

elbu

kgCO2eq.

PJF000Z589 B

Page 109: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT125VSAWPVH

- 108 -

Model(s) : FDC125VSA-W / FDT60VH (x2 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.6 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

330.0 %

Prated,c 12.5 kW 315.5 %

m3/h

519.0 %

950.0 %

Contact details

LWA 71.0 dB

NOx*** -

675

1960.0 %

0.25

4500

kgCO2eq.

PJF000Z589 B

Page 110: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 109 -

Information to identify the model(s) to which the information relates : FDC125VSA-W / FDT60VH (x2 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%205.1

No

Prated,h 14.0 kW

662.0 %

985.0 %

328.0 %

508.0 %

0.25

270.0 %

220.0 %

- %

- ℃

NOx*** -

675

Contact details

4380

- kW

m3/h

LWA 71.0 dB- m3/h

PSB 0.008 kW

elbu

kgCO2eq.

PJF000Z589 B

Page 111: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT140VNAWPVH

- 110 -

Model(s) : FDC140VNA-W / FDT71VH (x2 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

322.0 %

Prated,c 13.6 kW 313.3 %

m3/h

530.0 %

870.0 %

Contact details

LWA 72.0 dB

NOx*** -

675

2200.0 %

0.25

4500

kgCO2eq.

PJF000Z589 B

Page 112: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 111 -

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDT71VH (x2 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%201.6

No

Prated,h 15.5 kW

330.0 %

500.0 %

640.0 %

940.0 %

0.25

270.0 %

220.0 %

- %

- ℃

- kW

m3/h

LWA 73.0 dB- m3/h

PSB 0.008 kW

elbu

NOx*** -

675

Contact details

4380

kgCO2eq.

PJF000Z589 B

Page 113: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT140VSAWPVH

- 112 -

Model(s) : FDC140VSA-W / FDT71VH (x2 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

322.0 %

Prated,c 13.6 kW 313.3 %

m3/h

530.0 %

870.0 %

Contact details

LWA 72.0 dB

NOx*** -

675

2200.0 %

0.25

4500

kgCO2eq.

PJF000Z589 B

Page 114: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 113 -

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDT71VH (x2 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%201.6

No

Prated,h 15.5 kW

330.0 %

500.0 %

640.0 %

940.0 %

0.25

270.0 %

220.0 %

- %

- ℃

- kW

m3/h

LWA 73.0 dB- m3/h

PSB 0.008 kW

elbu

NOx*** -

675

Contact details

4380

kgCO2eq.

PJF000Z589 B

Page 115: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT140VNAWTVH

- 114 -

Model(s) : FDC140VNA-W / FDT50VH (x3 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Prated,c 13.6 kW 313.3 %

322.0 %

530.0 %

2200.0 %

870.0 %

0.25

4500 m3/h

675

LWA 72.0 dB

Contact details

NOx*** -

kgCO2eq.

PJF000Z589 B

Page 116: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 115 -

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDT50VH (x3 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

%201.6

No

Prated,h 15.5 kW

640.0 %

940.0 %

330.0 %

500.0 %

0.25

270.0 %

220.0 %

- %

- ℃

NOx*** -

675

Contact details

4380

- kW

m3/h

LWA 73.0 dB- m3/h

PSB 0.008 kW

elbu

kgCO2eq.

PJF000Z589 B

Page 117: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

FDT140VSAWTVH

- 116 -

Model(s) : FDC140VSA-W / FDT50VH (x3 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Prated,c 13.6 kW 313.3 %

322.0 %

530.0 %

2200.0 %

870.0 %

0.25

4500 m3/h

675

LWA 72.0 dB

Contact details

NOx*** -

kgCO2eq.

PJF000Z589 B

Page 118: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

- 117 -

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDT50VH (x3 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

675

Contact details

4380

LWA 73.0 dB- m3/h

elbu - kW

PSB 0.008 kW

m3/h

NOx*** -

0.25

270.0 %

220.0 %

- %

- ℃

500.0 %

201.6

640.0 %

940.0 %

No

Prated,h 15.5 kW %

330.0 %

kgCO2eq.

PJF000Z589 B

Page 119: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

'19 • PAC-DB-308D

Models FDT50VH, 60VH, 71VH, 100VH, 125VH, 140VH

- 118 -

Model(s) :

Item Symbol Value Unit Item Symbol Value Unit

Cooling capacity (sensible) Prated,c 3.9 kW Total electric power input Pelec 0.030 kW

Cooling capacity (latent) Prated,c 0.1 kW LWA 50.0 dB

Heating capacity Prated,h 4.5 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Value Unit Item Symbol Value Unit

Cooling capacity (sensible) Prated,c 4.4 kW Total electric power input Pelec 0.040 kW

Cooling capacity (latent) Prated,c 0.6 kW LWA 55.0 dB

Heating capacity Prated,h 5.4 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Value Unit Item Symbol Value Unit

Cooling capacity (sensible) Prated,c 5.5 kW Total electric power input Pelec 0.070 kW

Cooling capacity (latent) Prated,c 0.1 kW LWA 58.0 dB

Heating capacity Prated,h 6.7 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Value Unit Item Symbol Value Unit

Cooling capacity (sensible) Prated,c 6.2 kW Total electric power input Pelec 0.080 kW

Cooling capacity (latent) Prated,c 0.9 kW LWA 59.0 dB

Heating capacity Prated,h 8.0 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Value Unit Item Symbol Value Unit

Cooling capacity (sensible) Prated,c 8.4 kW Total electric power input Pelec 0.130 kW

Cooling capacity (latent) Prated,c 1.6 kW LWA 62.0 dB

Heating capacity Prated,h 11.2 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Value Unit Item Symbol Value Unit

Cooling capacity (sensible) Prated,c 9.6 kW Total electric power input Pelec 0.140 kW

Cooling capacity (latent) Prated,c 2.9 kW LWA 63.0 dB

Heating capacity Prated,h 14.0 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Value Unit Item Symbol Value Unit

Cooling capacity (sensible) Prated,c 10.4 kW Total electric power input Pelec 0.140 kW

Cooling capacity (latent) Prated,c 3.6 kW LWA 63.0 dB

Heating capacity Prated,h 16.0 kW

Mitsubishi heavy industries thermal systems,LTD

Contact details

FDT40VH

Sound power level(per speed setting,if applicable)

Contact details

FDT50VH

Sound power level(per speed setting,if applicable)

Contact details

FDT60VH

Sound power level(per speed setting,if applicable)

Contact details

FDT71VH

Sound power level(per speed setting,if applicable)

FDT140VH

Sound power level(per speed setting,if applicable)

Contact details

FDT100VH

Sound power level(per speed setting,if applicable)

Contact details

FDT125VH

Sound power level(per speed setting,if applicable)

Contact details

PJF000Z589 B

Page 120: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 119 -

'19 • PAC-DB-308D

(2) Ceiling cassette-4 way compact type (FDTC)

FDTC100VNAWPVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDTC50VH (x2 units) information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.17 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.38 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.17 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 4.80 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 7.50 -Tj=20℃ Pdc 3.25 kW Tj=20℃ EERd 12.00 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.04 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.30 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.50 -Tj=12℃ Pdh 2.82 kW Tj=12℃ COPd 6.60 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.50 -Tj=operating limit Pdh 6.20 kW Tj=operating limit COPd 2.10 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 10 W cooling Qce 567 kWh/astandby mode Psb 10 W heating / Average Qhe 2715 kWh/athermostat-off mode Pto(cooling) 15 W heating / Warmer Qhe - kWh/a

Pto(heating) 30 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 59 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 780 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

PJF000Z517 B

Page 121: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 120 -

'19 • PAC-DB-308D

FDTC100VSAWPVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDTC50VH (x2 units) information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.17 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.38 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.17 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 4.80 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 7.50 -Tj=20℃ Pdc 3.25 kW Tj=20℃ EERd 12.00 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.04 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.30 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.50 -Tj=12℃ Pdh 2.82 kW Tj=12℃ COPd 6.60 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.50 -Tj=operating limit Pdh 6.20 kW Tj=operating limit COPd 2.10 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 10 W cooling Qce 567 kWh/astandby mode Psb 10 W heating / Average Qhe 2715 kWh/athermostat-off mode Pto(cooling) 15 W heating / Warmer Qhe - kWh/a

Pto(heating) 30 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 59 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 780 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

PJF000Z517 B

Page 122: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 121 -

'19 • PAC-DB-308D

FDT125VNAWPVH

Model(s) : FDC125VNA-W / FDTC60VH (x2 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.5 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.010 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.010 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

255.0 %

Prated,c 12.5 kW 260.6 %

450.0 %

739.0 %

1782.0 %

0.25

4500 m3/h

Contact details

LWA 71.0 dB

NOx*** -

675kgCO2eq.

PJF000Z517 B

Page 123: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 122 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC125VNA-W / FDTC60VH (x2 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.010 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

LWA 71.0 dB- m3/h

- %

- ℃

PSB 0.010 kW

4380 m3/h

0.25

No

Prated,h 14.0 kW 171.3 %

270.0 %

420.0 %

580.0 %

805.0 %

230.0 %

200.0 %

elbu - kW

kgCO2eq.

PJF000Z517 B

Page 124: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 123 -

'19 • PAC-DB-308D

FDTC125VSAWPVH

Model(s) : FDC125VSA-W / FDTC60VH (x2 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.5 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.010 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.010 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

255.0 %

Prated,c 12.5 kW 260.6 %

450.0 %

739.0 %

1782.0 %

0.25

4500 m3/h

Contact details

LWA 71.0 dB

NOx*** -

675kgCO2eq.

PJF000Z517 B

Page 125: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 124 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC125VSA-W / FDTC60VH (x2 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.010 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

LWA 71.0 dB- m3/h

- %

- ℃

PSB 0.010 kW

4380 m3/h

0.25

No

Prated,h 14.0 kW 171.3 %

270.0 %

420.0 %

580.0 %

805.0 %

230.0 %

200.0 %

elbu - kW

kgCO2eq.

PJF000Z517 B

Page 126: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 125 -

'19 • PAC-DB-308D

FDTC140VNAWTVH

Model(s) : FDC140VNA-W / FDTC50VH (x3 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.5 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

286.0 %

Prated,c 13.6 kW 271.4 %

442.0 %

773.0 %

1860.0 %

0.25

4500 m3/h

Contact details

LWA 72.0 dB

NOx*** -

675kgCO2eq.

PJF000Z517 B

Page 127: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 126 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDTC50VH (x3 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.8 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

LWA 73.0 dB- m3/h

- %

- ℃

PSB 0.008 kW

4380 m3/h

0.25

No

Prated,h 15.5 kW 196.0 %

317.0 %

474.0 %

660.0 %

963.0 %

240.0 %

200.0 %

elbu - kW

kgCO2eq.

PJF000Z517 B

Page 128: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 127 -

'19 • PAC-DB-308D

FDTC140VSAWTVH

Model(s) : FDC140VSA-W / FDTC50VH (x3 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.5 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

286.0 %

Prated,c 13.6 kW 271.4 %

442.0 %

773.0 %

1860.0 %

0.25

4500 m3/h

Contact details

LWA 72.0 dB

NOx*** -

675kgCO2eq.

PJF000Z517 B

Page 129: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 128 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDTC50VH (x3 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.8 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

LWA 73.0 dB- m3/h

- %

- ℃

PSB 0.008 kW

4380 m3/h

0.25

No

Prated,h 15.5 kW 196.0 %

317.0 %

474.0 %

660.0 %

963.0 %

240.0 %

200.0 %

elbu - kW

kgCO2eq.

PJF000Z517 B

Page 130: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 129 -

'19 • PAC-DB-308D

Models FDTC50VH, 60VH

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 3.8 kW Total electric power input Pelec 0.050 kW

Cooling capacity (latent) Prated,c 1.2 kW LWA 59.0 dB

Heating capacity Prated,h 5.4 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 3.9 kW Total electric power input Pelec 0.060 kW

Cooling capacity (latent) Prated,c 1.7 kW LWA 60.0 dB

Heating capacity Prated,h 6.7 kW

Mitsubishi heavy industries thermal systems,LTD

FDTC50VH

Sound power level(per speed setting,if applicable)

Contact details

FDTC60VH

Sound power level(per speed setting,if applicable)

Contact details

PJF000Z517 B

Page 131: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 130 -

'19 • PAC-DB-308D

PJG000Z625 A

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDU100VH information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.11 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.19 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.35 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.00 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 8.05 -Tj=20℃ Pdc 3.10 kW Tj=20℃ EERd 9.50 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.14 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.02 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.24 -Tj=12℃ Pdh 2.90 kW Tj=12℃ COPd 6.27 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.50 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.10 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol -20 ℃heating / Colder Tbiv - ℃ heating / Colder Tol -20 ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 8 W cooling Qce 574 kWh/astandby mode Psb 8 W heating / Average Qhe 2843 kWh/athermostat-off mode Pto(cooling) 65 W heating / Warmer Qhe - kWh/a

Pto(heating) 75 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 65 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 2,160 m3/hvariable Yes Rated air flow(outdoor) - 4,500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

(3) Duct connected-High static pressure type (FDU)

FDU100VNAWVH

Page 132: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 131 -

'19 • PAC-DB-308D

FDU100VSAWVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDU100VH information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.11 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.19 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.35 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.00 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 8.05 -Tj=20℃ Pdc 3.10 kW Tj=20℃ EERd 9.50 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.14 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.02 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.24 -Tj=12℃ Pdh 2.90 kW Tj=12℃ COPd 6.27 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.50 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.10 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol -20 ℃heating / Colder Tbiv - ℃ heating / Colder Tol -20 ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 8.0 W cooling Qce 574 kWh/astandby mode Psb 8.0 W heating / Average Qhe 2843 kWh/athermostat-off mode Pto(cooling) 65.0 W heating / Warmer Qhe - kWh/a

Pto(heating) 75.0 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5.0 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 65 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 2,160 m3/hvariable Yes Rated air flow(outdoor) - 4,500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

PJG000Z625 A

Page 133: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 132 -

'19 • PAC-DB-308D

PJG000Z625 A

Model(s) : FDC125VNA-W / FDU125VH

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.008 kW

Thermostat-off mode PTO 0.075 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Prated,c 12.5 kW 219.8 %

425.0 %

287.0 %

920.0 %

705.0 %

0.25

4,500 m3/h

LWA 71.0 dB

Contact details

NOx*** -

675kgCO2eq.

FDU125VNAWVH

Page 134: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 133 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC125VNA-W / FDU125VH

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 2.7 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.090 kW Type of energy inputCrankcase heater mode PCK 0.008 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

300.0 %

No

Prated,h 14.0 kW 162.1 %

615.0 %

270.0 %

399.0 %

515.0 %

- ℃

0.25

210.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 71.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

PJG000Z625 A

Page 135: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 134 -

'19 • PAC-DB-308D

PJG000Z625 A

Model(s) : FDC125VSA-W / FDU125VH

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.008 kW

Thermostat-off mode PTO 0.075 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Prated,c 12.5 kW 219.8 %

425.0 %

287.0 %

920.0 %

705.0 %

0.25

4,500 m3/h

LWA 71.0 dB

Contact details

NOx*** -

675kgCO2eq.

FDU125VSAWVH

Page 136: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 135 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC125VSA-W / FDU125VH

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 2.7 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.090 kW Type of energy inputCrankcase heater mode PCK 0.008 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

300.0 %

No

Prated,h 14.0 kW 162.1 %

615.0 %

270.0 %

399.0 %

515.0 %

- ℃

0.25

210.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 71.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

PJG000Z625 A

Page 137: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 136 -

'19 • PAC-DB-308D

PJG000Z625 A

Model(s) : FDC140VNA-W / FDU140VH

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.2 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.008 kW

Thermostat-off mode PTO 0.090 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Prated,c 13.6 kW 208.8 %

390.0 %

265.0 %

900.0 %

680.0 %

0.25

4,500 m3/h

LWA 72.0 dB

Contact details

NOx*** -

675kgCO2eq.

FDU140VNAWVH

Page 138: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 137 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDU140VH

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 2.7 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.100 kW Type of energy inputCrankcase heater mode PCK 0.008 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

295.0 %

No

Prated,h 15.5 kW 157.4 %

596.0 %

270.0 %

385.0 %

500.0 %

- ℃

0.25

220.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 73.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

PJG000Z625 A

Page 139: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 138 -

'19 • PAC-DB-308D

PJG000Z625 A

Model(s) : FDC140VSA-W / FDU140VH

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.2 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.008 kW

Thermostat-off mode PTO 0.090 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Prated,c 13.6 kW 208.8 %

390.0 %

265.0 %

900.0 %

680.0 %

0.25

4,500 m3/h

LWA 72.0 dB

Contact details

NOx*** -

675kgCO2eq.

FDU140VSAWVH

Page 140: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 139 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDU140VH

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 2.7 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.100 kW Type of energy inputCrankcase heater mode PCK 0.008 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

295.0 %

No

Prated,h 15.5 kW 157.4 %

596.0 %

270.0 %

385.0 %

500.0 %

- ℃

0.25

220.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 73.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

PJG000Z625 A

Page 141: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 140 -

'19 • PAC-DB-308D

Models FDU100VH, 125VH, 140VH

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 7.7 kW Total electric power input Pelec 0.350 kW

Cooling capacity (latent) Prated,c 2.3 kW LWA 65.0 dB

Heating capacity Prated,h 11.2 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 10.5 kW Total electric power input Pelec 0.400 kW

Cooling capacity (latent) Prated,c 2.0 kW LWA 67.0 dB

Heating capacity Prated,h 14.0 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 11.2 kW Total electric power input Pelec 0.550 kW

Cooling capacity (latent) Prated,c 2.8 kW LWA 70.0 dB

Heating capacity Prated,h 16.0 kW

Mitsubishi heavy industries thermal systems,LTD

FDU140VH

Sound power level(per speed setting,if applicable)

Contact details

FDU100VH

Sound power level(per speed setting,if applicable)

Contact details

FDU125VH

Sound power level(per speed setting,if applicable)

Contact details

PJG000Z625 A

Page 142: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 141 -

'19 • PAC-DB-308D

PJG000Z491 B

(4) Duct connected-Low/Middle static pressure type (FDUM)

FDUM100VNAWVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDUM100VH information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.11 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.19 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.35 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.00 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 8.05 -Tj=20℃ Pdc 3.10 kW Tj=20℃ EERd 9.50 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.14 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.02 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.24 -Tj=12℃ Pdh 2.90 kW Tj=12℃ COPd 6.27 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.50 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.10 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol -20 ℃heating / Colder Tbiv - ℃ heating / Colder Tol -20 ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 8 W cooling Qce 574 kWh/astandby mode Psb 8 W heating / Average Qhe 2843 kWh/athermostat-off mode Pto(cooling) 65 W heating / Warmer Qhe - kWh/a

Pto(heating) 75 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 65 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 2160 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

Page 143: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 142 -

'19 • PAC-DB-308D

PJG000Z491 B

FDUM100VSAWVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDUM100VH information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.11 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.19 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.35 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.00 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 8.05 -Tj=20℃ Pdc 3.10 kW Tj=20℃ EERd 9.50 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.14 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.02 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.24 -Tj=12℃ Pdh 2.90 kW Tj=12℃ COPd 6.27 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.50 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.10 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol -20 ℃heating / Colder Tbiv - ℃ heating / Colder Tol -20 ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 8 W cooling Qce 574 kWh/astandby mode Psb 8 W heating / Average Qhe 2843 kWh/athermostat-off mode Pto(cooling) 65 W heating / Warmer Qhe - kWh/a

Pto(heating) 75 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 65 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 2160 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

Page 144: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 143 -

'19 • PAC-DB-308D

FDUM100VNAWPVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDUM50VH x2 information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 5.82 A+heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.00 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.08 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.00 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 7.50 -Tj=20℃ Pdc 3.45 kW Tj=20℃ EERd 11.30 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 2.84 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.03 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 4.85 -Tj=12℃ Pdh 2.93 kW Tj=12℃ COPd 5.79 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.40 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.00 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 15 W cooling Qce 602 kWh/astandby mode Psb 15 W heating / Average Qhe 2974 kWh/athermostat-off mode Pto(cooling) 110 W heating / Warmer Qhe - kWh/a

Pto(heating) 130 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 60 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 780 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

PJG000Z491 B

Page 145: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 144 -

'19 • PAC-DB-308D

PJG000Z491 B

FDUM100VSAWPVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDUM50VH x2 information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 5.82 A+heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.00 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.08 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.00 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 7.50 -Tj=20℃ Pdc 3.45 kW Tj=20℃ EERd 11.30 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 2.84 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.03 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 4.85 -Tj=12℃ Pdh 2.93 kW Tj=12℃ COPd 5.79 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.40 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.00 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 15 W cooling Qce 602 kWh/astandby mode Psb 15 W heating / Average Qhe 2974 kWh/athermostat-off mode Pto(cooling) 110 W heating / Warmer Qhe - kWh/a

Pto(heating) 130 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 60 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 780 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

Page 146: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 145 -

'19 • PAC-DB-308D

FDUM125VNAWVH

Model(s) : FDC125VNA-W / FDUM125VH

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.008 kW

Thermostat-off mode PTO 0.075 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 71.0 dB

0.25

4,500 m3/h

920.0 %

705.0 %

425.0 %

287.0 %

Prated,c 12.5 kW 219.8 %

kgCO2eq.

PJG000Z491 B

Page 147: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 146 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC125VNA-W / FDUM125VH

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 2.7 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.090 kW Type of energy inputCrankcase heater mode PCK 0.008 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

300.0 %

No

Prated,h 14.0 kW 162.1 %

615.0 %

270.0 %

399.0 %

515.0 %

- ℃

0.25

210.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 71.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 148: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 147 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC125VSA-W / FDUM125VH

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.008 kW

Thermostat-off mode PTO 0.075 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 71.0 dB

0.25

4,500 m3/h

920.0 %

705.0 %

425.0 %

287.0 %

Prated,c 12.5 kW 219.8 %

kgCO2eq.

FDUM125VSAWVH

Page 149: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 148 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC125VSA-W / FDUM125VH

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 2.7 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.090 kW Type of energy inputCrankcase heater mode PCK 0.008 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

300.0 %

No

Prated,h 14.0 kW 162.1 %

615.0 %

270.0 %

399.0 %

515.0 %

- ℃

0.25

210.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 71.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 150: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 149 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC140VNA-W / FDUM140VH

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.2 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.008 kW

Thermostat-off mode PTO 0.090 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 72.0 dB

0.25

4,500 m3/h

900.0 %

680.0 %

390.0 %

265.0 %

Prated,c 13.6 kW 208.8 %

kgCO2eq.

FDUM140VNAWVH

Page 151: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 150 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDUM140VH

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 2.7 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.100 kW Type of energy inputCrankcase heater mode PCK 0.008 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

295.0 %

No

Prated,h 15.5 kW 157.4 %

596.0 %

270.0 %

385.0 %

500.0 %

- ℃

0.25

220.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 73.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 152: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 151 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC140VSA-W / FDUM140VH

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.2 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.008 kW

Thermostat-off mode PTO 0.090 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 72.0 dB

0.25

4,500 m3/h

900.0 %

680.0 %

390.0 %

265.0 %

Prated,c 13.6 kW 208.8 %

kgCO2eq.

FDUM140VSAWVH

Page 153: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 152 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDUM140VH

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 2.7 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.100 kW Type of energy inputCrankcase heater mode PCK 0.008 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

295.0 %

No

Prated,h 15.5 kW 157.4 %

596.0 %

270.0 %

385.0 %

500.0 %

- ℃

0.25

220.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 73.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 154: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 153 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC125VNA-W / FDUM60VH (2 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.6 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 71.0 dB

0.25

4,500 m3/h

1730.0 %

810.0 %

480.0 %

276.0 %

Prated,c 12.5 kW 277.3 %

kgCO2eq.

FDUM125VNAWPVH

Page 155: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 154 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC125VNA-W / FDUM60VH (2 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

310.0 %

No

Prated,h 14.0 kW 188.3 %

855.0 %

250.0 %

470.0 %

596.0 %

- ℃

0.25

210.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 71.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 156: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 155 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC125VSA-W / FDUM60VH (2 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.6 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 71.0 dB

0.25

4,500 m3/h

1730.0 %

810.0 %

480.0 %

276.0 %

Prated,c 12.5 kW 277.3 %

kgCO2eq.

FDUM125VSAWPVH

Page 157: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 156 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC125VSA-W / FDUM60VH (2 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

310.0 %

No

Prated,h 14.0 kW 188.3 %

855.0 %

250.0 %

470.0 %

596.0 %

- ℃

0.25

210.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 71.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 158: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 157 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC140VNA-W / FDUM71VH (2 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.3 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 72.0 dB

0.25

4,500 m3/h

1680.0 %

850.0 %

500.0 %

285.0 %

Prated,c 13.6 kW 288.0 %

kgCO2eq.

FDUM140VNAWPVH

Page 159: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 158 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDUM71VH (2 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

335.0 %

No

Prated,h 15.5 kW 205.7 %

933.0 %

250.0 %

506.0 %

678.0 %

- ℃

0.25

200.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 73.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 160: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 159 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC140VSA-W / FDUM71VH (2 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.3 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 72.0 dB

0.25

4,500 m3/h

1680.0 %

850.0 %

500.0 %

285.0 %

Prated,c 13.6 kW 288.0 %

kgCO2eq.

FDUM140VSAWPVH

Page 161: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 160 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDUM71VH (2 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

335.0 %

No

Prated,h 15.5 kW 205.7 %

933.0 %

250.0 %

506.0 %

678.0 %

- ℃

0.25

200.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 73.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 162: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 161 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC140VNA-W / FDUM50VH (3 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.3 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 72.0 dB

0.25

4,500 m3/h

1680.0 %

850.0 %

500.0 %

285.0 %

Prated,c 13.6 kW 288.0 %

kgCO2eq.

FDUM140VNAWTVH

Page 163: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 162 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDUM50VH (3 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

335.0 %

No

Prated,h 15.5 kW 205.7 %

933.0 %

250.0 %

506.0 %

678.0 %

- ℃

0.25

200.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 73.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 164: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 163 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) : FDC140VSA-W / FDUM50VH (3 units)

Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.3 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

NOx*** -

675

LWA 72.0 dB

0.25

4,500 m3/h

1680.0 %

850.0 %

500.0 %

285.0 %

Prated,c 13.6 kW 288.0 %

kgCO2eq.

FDUM140VSAWTVH

Page 165: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 164 -

'19 • PAC-DB-308D

PJG000Z491 B

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDUM50VH (3 units)

Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,binTj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,binTj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,binTj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,binTbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd or

temperature GUEh,bin / AEFh,binTOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperature

coefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

335.0 %

No

Prated,h 15.5 kW 205.7 %

933.0 %

250.0 %

506.0 %

678.0 %

- ℃

0.25

200.0 %

- %

PSB 0.008 kW

elbu - kW

4,380 m3/h

LWA 73.0 dB- m3/h

Contact details

NOx*** -

675kgCO2eq.

Page 166: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 165 -

'19 • PAC-DB-308D

PJG000Z491 B

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 3.7 kW Total electric power input Pelec 0.100 kW

Cooling capacity (latent) Prated,c 1.3 kW LWA 60.0 dB

Heating capacity Prated,h 5.4 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 3.9 kW Total electric power input Pelec 0.160 kW

Cooling capacity (latent) Prated,c 1.7 kW LWA 60.0 dB

Heating capacity Prated,h 6.7 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 5.8 kW Total electric power input Pelec 0.200 kW

Cooling capacity (latent) Prated,c 1.3 kW LWA 65.0 dB

Heating capacity Prated,h 8.0 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 7.7 kW Total electric power input Pelec 0.290 kW

Cooling capacity (latent) Prated,c 2.3 kW LWA 65.0 dB

Heating capacity Prated,h 11.2 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 10.5 kW Total electric power input Pelec 0.330 kW

Cooling capacity (latent) Prated,c 2.0 kW LWA 67.0 dB

Heating capacity Prated,h 14.0 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 11.2 kW Total electric power input Pelec 0.450 kW

Cooling capacity (latent) Prated,c 2.8 kW LWA 70.0 dB

Heating capacity Prated,h 16.0 kW

Mitsubishi heavy industries thermal systems,LTD

FDUM50VH

Sound power level(per speed setting,if applicable)

Contact details

FDUM60VH

Sound power level(per speed setting,if applicable)

Contact details

FDUM71VH

Sound power level(per speed setting,if applicable)

Contact details

FDUM100VH

Sound power level(per speed setting,if applicable)

Contact details

FDUM125VH

Sound power level(per speed setting,if applicable)

Contact details

FDUM140VH

Sound power level(per speed setting,if applicable)

Contact details

Models FDUM50VH, 60VH, 71VH, 100VH, 125VH, 140VH

Page 167: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 166 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDE100VH information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.67 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.31 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.51 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.29 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 8.79 -Tj=20℃ Pdc 3.10 kW Tj=20℃ EERd 10.60 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.10 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.16 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.35 -Tj=12℃ Pdh 2.90 kW Tj=12℃ COPd 6.70 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.80 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.20 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 8 W cooling Qce 525 kWh/astandby mode Psb 8 W heating / Average Qhe 2764 kWh/athermostat-off mode Pto(cooling) 26 W heating / Warmer Qhe - kWh/a

Pto(heating) 43 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 62 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 1920 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

(5) Ceiling suspended type (FDE)

FDE100VNAWVH

Page 168: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 167 -

'19 • PAC-DB-308D

PFA004Z088 B

FDE100VSAWVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDE100VH information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.67 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.31 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.51 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.29 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 8.79 -Tj=20℃ Pdc 3.10 kW Tj=20℃ EERd 10.60 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.10 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.16 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.35 -Tj=12℃ Pdh 2.90 kW Tj=12℃ COPd 6.70 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.80 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.20 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 8 W cooling Qce 525 kWh/astandby mode Psb 8 W heating / Average Qhe 2764 kWh/athermostat-off mode Pto(cooling) 26 W heating / Warmer Qhe - kWh/a

Pto(heating) 43 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 62 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 1920 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

Page 169: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 168 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDE50VHx2 information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.16 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.10 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.21 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.20 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 7.40 -Tj=20℃ Pdc 3.30 kW Tj=20℃ EERd 12.40 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 2.89 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.14 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 4.89 -Tj=12℃ Pdh 2.87 kW Tj=12℃ COPd 5.85 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.30 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.25 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 15 W cooling Qce 569 kWh/astandby mode Psb 15 W heating / Average Qhe 2906 kWh/athermostat-off mode Pto(cooling) 35 W heating / Warmer Qhe - kWh/a

Pto(heating) 55 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 62 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 780 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

FDE100VNAWPVH

Page 170: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 169 -

'19 • PAC-DB-308D

PFA004Z088 B

FDE100VSAWPVH

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name FDE50VHx2 information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.16 A++heating / Average Pdesignh 8.5 kW heating / Average SCOP/A 4.10 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.5 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.21 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.20 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 7.40 -Tj=20℃ Pdc 3.30 kW Tj=20℃ EERd 12.40 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 2.89 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.14 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 4.89 -Tj=12℃ Pdh 2.87 kW Tj=12℃ COPd 5.85 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.30 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.25 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 15 W cooling Qce 569 kWh/astandby mode Psb 15 W heating / Average Qhe 2906 kWh/athermostat-off mode Pto(cooling) 35 W heating / Warmer Qhe - kWh/a

Pto(heating) 55 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 62 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 780 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET,United Kingdom

Page 171: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 170 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC125VNA-W / FDE125VHOutdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.030 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

LWA 71.0 dB

NOx*** -

675

1034.0 %

0.25

4,500 m3/h

281.0 %

Prated,c 12.5 kW 238.1 %

449.0 %

739.0 %

kgCO2eq.

FDE125VNAWVH

Page 172: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 171 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC125VNA-W  / FDE125VHOutdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.045 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

4,380 m3/h

LWA 71.0 dB - m3/h

elbu - kW

PSB 0.008 kW

0.25

270.0 %

220.0 %

- %

- ℃

545.0 %

675.0 %

%

300.0 %

415.0 %

169.1

No

Prated,h 14.0 kW

kgCO2eq.

Page 173: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 172 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC125VSA-W / FDE125VHOutdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.030 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

281.0 %

Prated,c 12.5 kW 238.1 %

449.0 %

739.0 %

1034.0 %

0.25

4,500 m3/h

Contact details

LWA 71.0 dB

NOx*** -

675kgCO2eq.

FDE125VSAWVH

Page 174: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 173 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC125VSA-W / FDE125VHOutdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.045 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

4,380 m3/h

LWA 71.0 dB - m3/h

elbu - kW

PSB 0.008 kW

0.25

270.0 %

220.0 %

- %

- ℃

545.0 %

675.0 %

%

300.0 %

415.0 %

169.1

No

Prated,h 14.0 kW

kgCO2eq.

Page 175: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 174 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC140VNA-W / FDE140VHOutdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.030 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

269.0 %

Prated,c 13.6 kW 227.6 %

420.0 %

682.0 %

1034.0 %

0.25

4,500 m3/h

Contact details

LWA 72.0 dB

NOx*** -

675kgCO2eq.

FDE140VNAWVH

Page 176: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 175 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDE140VHOutdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.2 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.045 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 15.5 kW %

290.0 %

410.0 %

166.6

540.0 %

675.0 %

0.25

250.0 %

210.0 %

- %

- ℃

elbu - kW

PSB 0.008 kW

4,380 m3/h

LWA 73.0 dB - m3/h

NOx*** -

675

Contact details

kgCO2eq.

Page 177: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 176 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC140VSA-W / FDE140VHOutdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.1 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.030 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

269.0 %

Prated,c 13.6 kW 227.6 %

420.0 %

682.0 %

1034.0 %

0.25

4,500 m3/h

Contact details

LWA 72.0 dB

NOx*** -

675kgCO2eq.

FDE140VSAWVH

Page 178: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 177 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDE140VHOutdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.2 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.045 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 15.5 kW 166.6 %

290.0 %

410.0 %

540.0 %

675.0 %

%

- ℃

0.25

250.0 %

210.0 %

4,380 m3/h

LWA 73.0 dB - m3/h

elbu - kW

PSB 0.008 kW

-

NOx*** -

675

Contact details

kgCO2eq.

Page 179: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 178 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC125VNA-W / FDE60VH (2units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.5 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

LWA 71.0 dB

NOx*** -

675

1995.0 %

0.25

4,500 m3/h

487.0 %

853.0 %

303.0 %

Prated,c 12.5 kW 294.7 %

kgCO2eq.

FDE125VNAWPVH

Page 180: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 179 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC125VNA-W / FDE60VH (2units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 14.0 kW %

324.0 %

487.0 %

198.8

655.0 %

905.0 %

0.25

280.0 %

230.0 %

- %

- ℃

elbu - kW

PSB 0.008 kW

4,380 m3/h

LWA 71.0 dB - m3/h

NOx*** -

675

Contact details

kgCO2eq.

Page 181: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 180 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC125VSA-W / FDE60VH (2units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.5 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

LWA 71.0 dB

NOx*** -

675

1995.0 %

0.25

4,500 m3/h

487.0 %

853.0 %

303.0 %

Prated,c 12.5 kW 294.7 %

kgCO2eq.

FDE125VSAWPVH

Page 182: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 181 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC125VSA-W / FDE60VH (2units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 14.0 kW %

324.0 %

487.0 %

198.8

655.0 %

905.0 %

0.25

280.0 %

230.0 %

- %

- ℃

elbu - kW

PSB 0.008 kW

4,380 m3/h

LWA 71.0 dB - m3/h

NOx*** -

675

Contact details

kgCO2eq.

Page 183: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 182 -

'19 • PAC-DB-308D

PFA004Z088 B

FDE140VNAWPVH

Model(s) : FDC140VNA-W / FDE71VH (2units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

LWA 72.0 dB

NOx*** -

675

2026.0 %

0.25

4,500 m3/h

456.0 %

789.0 %

287.0 %

Prated,c 13.6 kW 279.5 %

kgCO2eq.

Page 184: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 183 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDE71VH (2units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 15.5 kW %

296.0 %

467.0 %

188.8

628.0 %

867.0 %

0.25

260.0 %

220.0 %

- %

- ℃

elbu - kW

PSB 0.008 kW

4,380 m3/h

LWA 73.0 dB - m3/h

NOx*** -

675

Contact details

kgCO2eq.

Page 185: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 184 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC140VSA-W / FDE71VH (2units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

LWA 72.0 dB

NOx*** -

675

2026.0 %

0.25

4,500 m3/h

456.0 %

789.0 %

287.0 %

Prated,c 13.6 kW 279.5 %

kgCO2eq.

FDE140VSAWPVH

Page 186: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 185 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDE71VH (2units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 15.5 kW %

296.0 %

467.0 %

188.8

628.0 %

867.0 %

0.25

260.0 %

220.0 %

- %

- ℃

elbu - kW

PSB 0.008 kW

4,380 m3/h

LWA 73.0 dB - m3/h

NOx*** -

675

Contact details

kgCO2eq.

Page 187: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 186 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC140VNA-W / FDE50VH (3units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

LWA 72.0 dB

NOx*** -

675

2026.0 %

0.25

4,500 m3/h

456.0 %

789.0 %

287.0 %

Prated,c 13.6 kW 279.5 %

kgCO2eq.

FDE140VNAWTVH

Page 188: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 187 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC140VNA-W / FDE50VH (3units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 15.5 kW %

296.0 %

467.0 %

188.8

628.0 %

867.0 %

0.25

260.0 %

220.0 %

- %

- ℃

elbu - kW

PSB 0.008 kW

4,380 m3/h

LWA 73.0 dB - m3/h

NOx*** -

675

Contact details

kgCO2eq.

Page 189: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 188 -

'19 • PAC-DB-308D

PFA004Z088 B

Model(s) : FDC140VSA-W / FDE50VH (3units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space

cooling energy η s,c

efficiency

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Contact details

LWA 72.0 dB

NOx*** -

675

2026.0 %

0.25

4,500 m3/h

456.0 %

789.0 %

287.0 %

Prated,c 13.6 kW 279.5 %

kgCO2eq.

FDE140VSAWTVH

Page 190: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 189 -

'19 • PAC-DB-308D

PFA004Z088 B

Information to identify the model(s) to which the information relates : FDC140VSA-W / FDE50VH (3units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :if applicable : electric motorParameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.Item Symbol Value Unit Item Symbol Value UnitRated heating capacity Seasonal space

heating energy η s,hefficiency

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd orGUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd orGUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd orGUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd orGUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd orGUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd orTj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heatpumps:Operation limit

Degradation Tol temperaturecoefficient Cdh -heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater back-up heating capacity

Off mode POFF 0.008 kWThermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other itemsFor air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchangerEmissions of nitrogen mg/kWhoxides(if applicable) fuel input

GCV

GWP of the refrigerant (100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.*** from 26 September 2018Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performanceof the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 15.5 kW %

296.0 %

467.0 %

188.8

628.0 %

867.0 %

0.25

260.0 %

220.0 %

- %

- ℃

elbu - kW

PSB 0.008 kW

4,380 m3/h

LWA 73.0 dB - m3/h

NOx*** -

675

Contact details

kgCO2eq.

Page 191: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 190 -

'19 • PAC-DB-308D

PFA004Z088 B

Models FDE50VH, 60VH, 71VH, 100VH, 125VH, 140VH

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 3.8 kW Total electric power input Pelec 0.050 kW

Cooling capacity (latent) Prated,c 1.2 kW LWA 60.0 dB

Heating capacity Prated,h 5.4 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 5.0 kW Total electric power input Pelec 0.080 kW

Cooling capacity (latent) Prated,c 0.6 kW LWA 60.0 dB

Heating capacity Prated,h 6.7 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 5.6 kW Total electric power input Pelec 0.080 kW

Cooling capacity (latent) Prated,c 1.5 kW LWA 60.0 dB

Heating capacity Prated,h 8.0 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 8.4 kW Total electric power input Pelec 0.130 kW

Cooling capacity (latent) Prated,c 1.6 kW LWA 64.0 dB

Heating capacity Prated,h 11.2 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 9.3 kW Total electric power input Pelec 0.130 kW

Cooling capacity (latent) Prated,c 3.2 kW LWA 64.0 dB

Heating capacity Prated,h 14.0 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 10.2 kW Total electric power input Pelec 0.140 kW

Cooling capacity (latent) Prated,c 3.8 kW LWA 65.0 dB

Heating capacity Prated,h 16.0 kW

Mitsubishi heavy industries thermal systems,LTD

Contact details

FDE100VH

Sound power level(per speed setting,if applicable)

Contact details

FDE125VH

Sound power level(per speed setting,if applicable)

Contact details

FDE50VH

Sound power level(per speed setting,if applicable)

Contact details

FDE60VH

Sound power level(per speed setting,if applicable)

Contact details

FDE71VH

Sound power level(per speed setting,if applicable)

FDE140VH

Sound power level(per speed setting,if applicable)

Contact details

Page 192: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 191 -

'19 • PAC-DB-308D

PCA001Z857 A

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name SRK100ZR-W information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.13 A++heating / Average Pdesignh 8.50 kW heating / Average SCOP/A 4.33 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.50 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.10 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 4.95 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 7.75 -Tj=20℃ Pdc 3.00 kW Tj=20℃ EERd 10.05 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.36 kW Tj=-7℃ COPd 2.75 -Tj=2℃ Pdh 4.47 kW Tj=2℃ COPd 4.18 -Tj=7℃ Pdh 2.88 kW Tj=7℃ COPd 5.74 -Tj=12℃ Pdh 2.95 kW Tj=12℃ COPd 7.46 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.77 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.10 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 7 W cooling Qce 571 kWh/astandby mode Psb 7 W heating / Average Qhe 2746 kWh/athermostat-off mode Pto(cooling) 30 W heating / Warmer Qhe - kWh/a

Pto(heating) 30 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 63 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 1470 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex,UB11 1ET, United kingdom

(6) Wall mounted type (SRK)

SRK100VNAWZR

Page 193: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 192 -

'19 • PAC-DB-308D

PCA001Z857 A

SRK100VSAWZR

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name SRK100ZR-W information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 6.13 A++heating / Average Pdesignh 8.50 kW heating / Average SCOP/A 4.33 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.50 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.10 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 4.95 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 7.75 -Tj=20℃ Pdc 3.00 kW Tj=20℃ EERd 10.05 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.36 kW Tj=-7℃ COPd 2.75 -Tj=2℃ Pdh 4.47 kW Tj=2℃ COPd 4.18 -Tj=7℃ Pdh 2.88 kW Tj=7℃ COPd 5.74 -Tj=12℃ Pdh 2.95 kW Tj=12℃ COPd 7.46 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.77 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.10 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 7 W cooling Qce 571 kWh/astandby mode Psb 7 W heating / Average Qhe 2746 kWh/athermostat-off mode Pto(cooling) 30 W heating / Warmer Qhe - kWh/a

Pto(heating) 30 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 63 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 1470 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex,UB11 1ET, United kingdom

Page 194: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 193 -

'19 • PAC-DB-308D

PCA001Z857 A

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name SRK50ZSX-W (x2 units) information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VNA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 7.05 A++heating / Average Pdesignh 8.50 kW heating / Average SCOP/A 4.47 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.50 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.46 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.30 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 9.20 -Tj=20℃ Pdc 3.58 kW Tj=20℃ EERd 15.30 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.06 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.28 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.86 -Tj=12℃ Pdh 2.93 kW Tj=12℃ COPd 7.55 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.40 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.00 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 10 W cooling Qce 497 kWh/astandby mode Psb 10 W heating / Average Qhe 2661 kWh/athermostat-off mode Pto(cooling) 50 W heating / Warmer Qhe - kWh/a

Pto(heating) 65 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 59 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 858 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex,UB11 1ET, United kingdom

SRK100VNAWPZSX

Page 195: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 194 -

'19 • PAC-DB-308D

PCA001Z857 A

SRK100VSAWPZSX

Information to identify the model(s) to which the information relates to: If function includes heating: Indicate the heating season theIndoor unit model name SRK50ZSX-W (x2 units) information relates to. Indicated values should relate to oneOutdoor unit model name FDC100VSA-W heating season at a time. Include at least the heating season 'Average'.

Function(indicate if present) Average(mandatory) Yescooling Yes Warmer(if designated) Noheating Yes Colder(if designated) No

Item symbol value unit Item symbol value classDesign load Seasonal efficiency and energy efficiency classcooling Pdesignc 10.0 kW cooling SEER 7.05 A++heating / Average Pdesignh 8.50 kW heating / Average SCOP/A 4.47 A+heating / Warmer Pdesignh - kW heating / Warmer SCOP/W - -heating / Colder Pdesignh - kW heating / Colder SCOP/C - -

unitDeclared capacity at outdoor temperature Tdesignh Back up heating capacity at outdoor temperature Tdesignhheating / Average (-10℃) Pdh 8.50 kW heating / Average (-10℃) elbu 0 kWheating / Warmer (2℃) Pdh - kW heating / Warmer (2℃) elbu - kWheating / Colder (-22℃) Pdh - kW heating / Colder (-22℃) elbu - kW

Declared capacity for cooling, at indoor temperature 27(19)℃ and Declared energy efficiency ratio, at indoor temperature 27(19)℃ andoutdoor temperature Tj outdoor temperature TjTj=35℃ Pdc 10.00 kW Tj=35℃ EERd 3.46 -Tj=30℃ Pdc 7.37 kW Tj=30℃ EERd 5.30 -Tj=25℃ Pdc 4.74 kW Tj=25℃ EERd 9.20 -Tj=20℃ Pdc 3.58 kW Tj=20℃ EERd 15.30 -

Declared capacity for heating / Average season, at indoor Declared coefficient of performance / Average season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh 7.40 kW Tj=-7℃ COPd 3.06 -Tj=2℃ Pdh 4.50 kW Tj=2℃ COPd 4.28 -Tj=7℃ Pdh 2.90 kW Tj=7℃ COPd 5.86 -Tj=12℃ Pdh 2.93 kW Tj=12℃ COPd 7.55 -Tj=bivalent temperature Pdh 8.50 kW Tj=bivalent temperature COPd 2.40 -Tj=operating limit Pdh 6.30 kW Tj=operating limit COPd 2.00 -

Declared capacity for heating / Warmer season, at indoor Declared coefficient of performance / Warmer season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -

Declared capacity for heating / Colder season, at indoor Declared coefficient of performance / Colder season, at indoortemperature 20℃ and outdoor temperature Tj temperature 20℃ and outdoor temperature TjTj=-7℃ Pdh - kW Tj=-7℃ COPd - -Tj=2℃ Pdh - kW Tj=2℃ COPd - -Tj=7℃ Pdh - kW Tj=7℃ COPd - -Tj=12℃ Pdh - kW Tj=12℃ COPd - -Tj=bivalent temperature Pdh - kW Tj=bivalent temperature COPd - -Tj=operating limit Pdh - kW Tj=operating limit COPd - -Tj=-15℃ Pdh - kW Tj=-15℃ COPd - -

Bivalent temperature Operating limit temperatureheating / Average Tbiv -10 ℃ heating / Average Tol -20 ℃heating / Warmer Tbiv - ℃ heating / Warmer Tol - ℃heating / Colder Tbiv - ℃ heating / Colder Tol - ℃

Cycling interval capacity Cycling interval efficiencyfor cooling Pcycc - kW for cooling EERcyc - -for heating Pcych - kW for heating COPcyc - -

Degradation coefficient Degradation coefficientcooling Cdc 0.25 - heating Cdh 0.25 -

Electric power input in power modes other than 'active mode' Annual electricity consumptionoff mode Poff 10 W cooling Qce 497 kWh/astandby mode Psb 10 W heating / Average Qhe 2661 kWh/athermostat-off mode Pto(cooling) 50 W heating / Warmer Qhe - kWh/a

Pto(heating) 65 W heating / colder Qhe - kWh/acrankcase heater mode Pck 5 W

Capacity control(indicate one of three options) Other itemsSound power level(indoor) Lwa 59 dB(A)Sound power level(outdoor) Lwa 69 dB(A)

fixed No Global warming potential GWP 675 kgCO2eq.staged No Rated air flow(indoor) - 858 m3/hvariable Yes Rated air flow(outdoor) - 4500 m3/h

Contact details for obtaining Name and address of the manufacturer or of its authorised representative.more information Mitsubishi Heavy Industries Air-Conditioning Europe, Ltd.

5 The Square, Stockley Park, Uxbridge, Middlesex,UB11 1ET, United kingdom

Page 196: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 195 -

'19 • PAC-DB-308D

PCA001Z857 A

Model(s) : FDC125VNA-W / SRK60ZSX-W (x2 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.4 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

0.25

4500 m3/h

Contact details

LWA 71.0 dB

NOx*** -

675

Prated,c 12.5 kW 295.4 %

276.0 %

480.0 %

880.0 %

2130.0 %

kgCO2eq.

SRK125VNAWPZSX

Page 197: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 196 -

'19 • PAC-DB-308D

PCA001Z857 A

Information to identify the model(s) to which the information relates : FDC125VNA-W / SRK60ZSX-W (x2 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

4380

- kW

m3/h

LWA 71.0 dB- m3/h

PSB 0.008 kW

elbu

0.25

270.0 %

210.0 %

- %

- ℃

944.0 %

310.0 %

458.0 %

%192.5

No

Prated,h 14.0 kW

671.0 %

kgCO2eq.

Page 198: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 197 -

'19 • PAC-DB-308D

PCA001Z857 A

Model(s) : FDC125VSA-W / SRK60ZSX-W (x2 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 12.5 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 9.2 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 5.9 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.4 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.008 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.008 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

276.0 %

Prated,c 12.5 kW 295.4 %

m3/h

480.0 %

880.0 %

Contact details

LWA 71.0 dB

NOx*** -

675

2130.0 %

0.25

4500

kgCO2eq.

SRK125VSAWPZSX

Page 199: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 198 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC125VSA-W / SRK60ZSX-W (x2 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 8.7 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.3 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.4 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.0 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 9.8 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.4 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.008 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

4380

- kW

m3/h

LWA 71.0 dB- m3/h

PSB 0.008 kW

elbu

0.25

270.0 %

210.0 %

- %

- ℃

944.0 %

310.0 %

458.0 %

%192.5

No

Prated,h 14.0 kW

671.0 %

kgCO2eq.

PCA001Z857 A

Page 200: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 199 -

'19 • PAC-DB-308D

PCA001Z857 A

Model(s) : FDC140VNA-W / SRK71ZR-W (x2 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.010 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.010 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

319.0 %

Prated,c 13.6 kW 311.5 %

m3/h

540.0 %

890.0 %

Contact details

LWA 72.0 dB

NOx*** -

675

2270.0 %

0.25

4500

kgCO2eq.

SRK140VNAWPZR

Page 201: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 200 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC140VNA-W / SRK71ZR-W (x2 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.010 kW

Thermostat-off mode PTO 0.020 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

4380

- kW

m3/h

LWA 73.0 dB- m3/h

PSB 0.010 kW

elbu

0.25

250.0 %

200.0 %

- %

- ℃

736.0 %

1090.0 %

320.0 %

504.0 %

%209.5

No

Prated,h 15.5 kW

kgCO2eq.

PCA001Z857 A

Page 202: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 201 -

'19 • PAC-DB-308D

PCA001Z857 A

Model(s) : FDC140VSA-W / SRK71ZR-W (x2 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.010 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.010 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

319.0 %

Prated,c 13.6 kW 311.5 %

m3/h

540.0 %

890.0 %

Contact details

LWA 72.0 dB

NOx*** -

675

2270.0 %

0.25

4500

kgCO2eq.

SRK140VSAWPZR

Page 203: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 202 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC140VSA-W / SRK71ZR-W (x2 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.010 kW

Thermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

4380

- kW

m3/h

LWA 73.0 dB- m3/h

PSB 0.010 kW

elbu

0.25

250.0 %

200.0 %

- %

- ℃

750.0 %

1120.0 %

349.0 %

529.0 %

%219.6

No

Prated,h 15.5 kW

kgCO2eq.

PCA001Z857 A

Page 204: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 203 -

'19 • PAC-DB-308D

PCA001Z857 A

Model(s) : FDC140VNA-W / SRK50ZSX-W (x3 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.010 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.010 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Prated,c 13.6 kW 311.5 %

319.0 %

540.0 %

2270.0 %

890.0 %

0.25

4500 m3/h

675

LWA 72.0 dB

Contact details

NOx*** -

kgCO2eq.

SRK140VNAWTZSX

Page 205: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 204 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC140VNA-W / SRK50ZSX-W (x3 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.010 kW

Thermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

NOx*** -

675

Contact details

4380

- kW

m3/h

LWA 73.0 dB- m3/h

PSB 0.010 kW

elbu

0.25

250.0 %

200.0 %

- %

- ℃

1120.0 %

349.0 %

529.0 %

%219.6

No

Prated,h 15.5 kW

750.0 %

kgCO2eq.

PCA001Z857 A

Page 206: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 205 -

'19 • PAC-DB-308D

PCA001Z857 A

Model(s) : FDC140VSA-W / SRK50ZSX-W (x3 units)Outdoor side heat exchanger of air conditioner : airIndoor side heat exchanger of air conditioner : airType : vapour compression

if applicable : electric motor

Item Symbol Value Unit Item Symbol Value Unit

Rated cooling capacity Seasonal space cooling energy

efficiency ηs,c

Declared cooling capacity for part load at given outdoor temperatures Declared energy efficiency ratio or gas utilization efficiency /

Tj and indoor 27℃/19℃(dry/wet bulb) auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=+35℃ Pdc 13.6 kW Tj=+35℃ EERd or

GUEc,bin / AEFc,bin

Tj=+30℃ Pdc 10.0 kW Tj=+30℃ EERd or

GUEc,bin / AEFc,bin

Tj=+25℃ Pdc 6.4 kW Tj=+25℃ EERd or

GUEc,bin / AEFc,bin

Tj=+20℃ Pdc 3.7 kW Tj=+20℃ EERd or

GUEc,bin / AEFc,bin

Degradation

coefficient for Cdc -

air conditioners**

Power consumpiton in other than 'active mode'

Off mode POFF 0.010 kW Crankcase heater mode PCK 0.005 kW

Thermostat-off mode PTO 0.000 kW Standby mode PSB 0.010 kW

Other items

For air-to-air air conditioner:Capacity control variable air flow-rate,outdoor measured

Sound power level,

outdoor

If engine driven: mg/kWh

Emissions of nitrogen fuel input

oxides GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

Prated,c 13.6 kW 311.5 %

319.0 %

540.0 %

2270.0 %

890.0 %

0.25

4500 m3/h

675

LWA 72.0 dB

Contact details

NOx*** -

kgCO2eq.

SRK140VSAWTZSX

Page 207: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 206 -

'19 • PAC-DB-308D

Information to identify the model(s) to which the information relates : FDC140VSA-W / SRK50ZSX-W (x3 units)Outdoor side heat exchanger of heat pump : airIndoor side heat exchanger of heat pump : airIndication if the heater is equipped with a supplementary heater :

if applicable : electric motor

Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.

Item Symbol Value Unit Item Symbol Value Unit

Rated heating capacity Seasonal space heating energy efficiency ηs,h

Declared heating capacity for part load at indoor temperature 20℃ Declared coefficient of performance or gas utilization efficiency /

and outdoor temperature Tj auxiliary energy factor for part load at given outdoor temperatures Tj

Tj=-7℃ Pdh 9.3 kW Tj=-7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+2℃ Pdh 5.6 kW Tj=+2℃ COPd or

GUEh,bin / AEFh,bin

Tj=+7℃ Pdh 3.6 kW Tj=+7℃ COPd or

GUEh,bin / AEFh,bin

Tj=+12℃ Pdh 3.1 kW Tj=+12℃ COPd or

GUEh,bin / AEFh,bin

Tbiv=bivalent temperature Pdh 10.5 kW Tbiv=bivalent COPd ortemperature

GUEh,bin / AEFh,bin

TOL=operation limit Pdh 7.9 kW TOL=operation limit COPd or

GUEh,bin / AEFh,bin

For air-to-water heat pumps : Pdh - kW For air-to-water heat COPd or

Tj=-15℃ pumps:Tj=-15℃ GUEh,bin / AEFh,bin

(if TOL<-20℃) (if TOL<-20℃)

Bivalent temperature Tbiv -10.0 ℃ For water-to-air heat

pumps:Operation limit

Degradation Tol temperature

coefficient Cdh -

heat pumps**

Power consumpiton in modes other than 'active mode' Supplementary heater

back-up heating capacityOff mode POFF 0.010 kW

Thermostat-off mode PTO 0.000 kW Type of energy inputCrankcase heater mode PCK 0.005 kW Standby mode

Other items

For air-to-air heat pumps:

Capacity control variable air flow-rate,outdoor measured

Sound power level, For water-/brine-to-air heat pumps :

outdoor measured Rated brine or water fiow-rate,

outdoor side heat exchanger

Emissions of nitrogen mg/kWh

oxides(if applicable) fuel input

GCV

GWP of the

refrigerant(100years)

Mitsubishi heavy industries thermal systems,LTD ** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.

*** from 26 September 2018

Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance

of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.

No

Prated,h 15.5 kW %

349.0 %

529.0 %

219.6

750.0 %

1120.0 %

0.25

250.0 %

200.0 %

- %

- ℃

675

Contact details

4380

LWA 73.0 dB- m3/h

elbu - kW

PSB 0.010 kW

m3/h

NOx*** -

kgCO2eq.

PCA001Z857 A

Page 208: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 207 -

'19 • PAC-DB-308D

PCA001Z857 A

Models SRK50ZSX-W, 60ZSX-W, 71ZR-W, 100ZR-W

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 4.0 kW Total electric power input Pelec 0.030 kW

Cooling capacity (latent) Prated,c 1.0 kW LWA 59.0 dB

Heating capacity Prated,h 6.0 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 4.7 kW Total electric power input Pelec 0.040 kW

Cooling capacity (latent) Prated,c 1.4 kW LWA 62.0 dB

Heating capacity Prated,h 6.8 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 5.2 kW Total electric power input Pelec 0.056 kW

Cooling capacity (latent) Prated,c 1.9 kW LWA 60.0 dB

Heating capacity Prated,h 7.1 kW

Mitsubishi heavy industries thermal systems,LTD

Model(s) :

Item Symbol Vaiue Unit Item Symbol Vaiue Unit

Cooling capacity (sensible) Prated,c 7.4 kW Total electric power input Pelec 0.060 kW

Cooling capacity (latent) Prated,c 2.6 kW LWA 63.0 dB

Heating capacity Prated,h 11.2 kW

Mitsubishi heavy industries thermal systems,LTD Contact details

SRK50ZSX-W

Sound power level(per speed setting,if applicable)

Contact details

SRK60ZSX-W

Sound power level(per speed setting,if applicable)

Contact details

SRK71ZR-W

Sound power level(per speed setting,if applicable)

Contact details

SRK100ZR-W

Sound power level(per speed setting,if applicable)

Page 209: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 208 -

'19 • PAC-DB-308D

2. V MULTI SYSTEM

CONTENTS

2.1 GENERAL INFORMATION

2.1 GENERAL INFORMATION

....................................................................................208.........................................................................208

..............................................................................................209......................................................................209

2.1.1 How to read the model name

2.1.1 How to read the model name

2.1.2 Table of models2.1.3 Table of system combinations

2.2 SPECIFICATIONS(1) Indoor units

(a) Ceiling cassette-4 way type (FDT)(b) Ceiling suspended type (FDE)

(2) Outdoor units(3) Operation chart

2.3 EXTERIOR DIMENSIONS2.4 ELECTRICAL WIRING2.5 TECHNICAL INFORMATION

.................................................................................................210.........................................................................................................210

..................................................................210........................................................................213

......................................................................................................216....................................................................................................222

......................................................................................225...........................................................................................225

..................................................................................225

Example: FDT 50 VH

Series code

Product capacity

Model name FDT : Ceiling cassette-4 way typeFDE : Ceiling suspended type

Example: FDC 100 VNA-W

Applicable power source...See the specificationProduct capacityModel name (FDC : Outdoor unit)

Page 210: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 209 -

'19 • PAC-DB-308D

2.1.2 Table of models

2.1.3 Table of system combinations

Notes(1) Always use the branch piping set (option) at branches in the refrigerant piping. Notes(2) If wireless specifications are used, use 1 wireless indoor unit in combination with wired indoor units.Notes(3) The combinations except the above table forbids.

CapacityModel

Ceiling cassette-4 way type (FDT)

Ceiling suspended type (FDE)

Outdoor unit to be combined (FDC)

50 60 71

FDC100VNA-WFDC100VSA-W(4 HP)

FDC125VNA-WFDC125VSA-W(5 HP)

FDC140VNA-WFDC140VSA-W(6 HP)

Indoor unit assembly capacity Branch pipe set(Option)

71+71

50+50+50

DIS-WA1G

DIS-TA1Gor

DIS-WA1G×2 sets

TypeOutdoor unit

50+50FDC100VNA-WFDC100VSA-W

60+6050+71

FDC125VNA-WFDC125VSA-W

FDC140VNA-WFDC140VSA-W

Twin

Twin

Triple

Page 211: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 210 -

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDT50VH

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Sound power levelCooling

dB(A)

55Heating 56

Sound pressure levelCooling P-Hi : 41 Hi : 33 Me : 30 Lo : 26Heating P-Hi : 42 Hi : 33 Me : 28 Lo : 20

Silent mode sound pressure level —

Exterior dimensions (Height × Width × Depth) mmUnit 236 × 840 × 840Panel 35 × 950 × 950

Exterior appearance( Munsell color )

Plaster white( 6.8Y8.9/0.2 ) near equivalent

Net weight kgUnit 19Panel 5

Heat exchanger Louver fin & inner grooved tubingFan type & Q'ty Turbo fan ×1Fan motor (Starting method) W 50 < Direct line start >

Air flow Cooling

m3/min P-Hi : 22 Hi : 16 Me : 13 Lo : 10Heating

Available external static pressure Pa 0Outside air intake PossibleAir filter, Quality / Quantity Pocket plastic net ×1 (Washable)Shock & vibration absorber Rubber sleeve (for fan motor)Electric heater W —

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipmentsInternal thermostat for fan motor.

Frost protection thermostat.

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ 6.35 (1/4") Gas line: φ 12.7 (1/2")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Drain hose Hose connectable VP25 (O.D.32)

Drain pump, max lift height mm Built-in drain pump, 850IP number IPX0Standard accessories Mounting kit, Drain hoseOption parts —Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

2.2 SPECIFICATIONS(1) Indoor units

(a) Ceiling cassette -4 way type (FDT)

Page 212: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 211 -

'19 • PAC-DB-308D

ModelItem

FDT60VH

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Sound power levelCooling

dB(A)

58Heating 59

Sound pressure levelCooling P-Hi : 44 Hi : 34 Me : 30 Lo : 27Heating P-Hi : 44 Hi : 34 Me : 30 Lo : 23

Silent mode sound pressure level —

Exterior dimensions (Height × Width × Depth) mmUnit 236 × 840 × 840Panel 35 × 950 × 950

Exterior appearance( Munsell color )

Plaster white( 6.8Y8.9/0.2 ) near equivalent

Net weight kgUnit 21Panel 5

Heat exchanger Louver fin & inner grooved tubingFan type & Q'ty Turbo fan ×1Fan motor (Starting method) W 50 < Direct line start >

Air flow Cooling

m3/min P-Hi : 26 Hi : 17 Me : 14 Lo : 11Heating

Available external static pressure Pa 0Outside air intake PossibleAir filter, Quality / Quantity Pocket plastic net ×1 (Washable)Shock & vibration absorber Rubber sleeve (for fan motor)Electric heater W —

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipmentsInternal thermostat for fan motor.

Frost protection thermostat.

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ 6.35 (1/4") Gas line: φ 12.7 (1/2")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Drain hose Hose connectable VP25 (O.D.32)

Drain pump, max lift height mm Built-in drain pump, 850IP number IPX0Standard accessories Mounting kit, Drain hoseOption parts —Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PJF000Z589 B

Page 213: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 212 -

'19 • PAC-DB-308D

ModelItem

FDT71VH

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Sound power levelCooling

dB(A)

59Heating 60

Sound pressure levelCooling P-Hi : 46 Hi : 34 Me : 31 Lo : 26Heating P-Hi : 46 Hi : 34 Me : 31 Lo : 26

Silent mode sound pressure level —

Exterior dimensions (Height × Width × Depth) mmUnit 236 × 840 × 840Panel 35 × 950 × 950

Exterior appearance( Munsell color )

Plaster white( 6.8Y8.9/0.2 ) near equivalent

Net weight kgUnit 21Panel 5

Heat exchanger Louver fin & inner grooved tubingFan type & Q'ty Turbo fan ×1Fan motor (Starting method) W 50 < Direct line start >

Air flow Cooling

m3/min P-Hi : 28 Hi : 18 Me : 15 Lo : 12Heating

Available external static pressure Pa 0Outside air intake PossibleAir filter, Quality / Quantity Pocket plastic net ×1 (Washable)Shock & vibration absorber Rubber sleeve (for fan motor)Electric heater W —

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2Room temperature control Thermostat by electronicsOperation display —

Safety equipmentsInternal thermostat for fan motor.

Frost protection thermostat.

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ 9.52 (3/8") Gas line: φ 15.88 (5/8")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Drain hose Hose connectable VP25 (O.D.28)

Drain pump, max lift height mm Built-in drain pump, 850IP number IPX0Standard accessories Mounting kit, Drain hoseOption parts —Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

PJF000Z589 B

Page 214: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 213 -

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem FDE50VH

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity kW 5.0Nominal heating capacity kW 5.4

Sound power levelCooling

dB(A)

60Heating

Sound pressure levelCooling

P-Hi : 46 Hi : 38 Me : 36 Lo : 31Heating

Silent mode sound pressure level —

Exterior dimensions (Height x Width x Depth) mm 210 × 1070 × 690

Exterior appearance( Munsell color )( RAL color )

Plaster white( 6.8Y8.9/0.2 ) near equivalent( RAL 9003 ) near equivalent

Net weight kg 28Heat exchanger Louver fin & inner grooved tubingFan type & Q'ty Centrifugal fan ×2Fan motor (Starting method) W 30 < Direct line start >

Air flowCooling

m3/min P-Hi : 13 Hi : 10 Me : 9 Lo : 7Heating

Available external static pressure Pa 0Outside air intake Not possibleAir filter, Quality / Quantity Pocket plastic net ×2(Washable)Shock & vibration absorber Rubber sleeve(for fan motor)Electric heater W —

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipmentsOverload protection for fan motor

Frost protection thermostat

Installationdata

Refrigerant piping size ( O.D. ) mmLiquid line: φ6.35 (1/4")Gas line: φ12.7 (1/2")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Drain hose Hose connectable VP20(O.D.26)

Drain pump, max lift height mm —IP number IPX0Standard accessories Mounting kit, Drain hoseOption parts Motion sensor : LB-E

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

Notes (1) The data are measured at the following conditions.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

(b) Ceiling suspended type (FDE)

Page 215: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 214 -

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem FDE60VH

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity kW 5.6Nominal heating capacity kW 6.7

Sound power levelCooling

dB(A)

60Heating

Sound pressure levelCooling

P-Hi : 47 Hi : 41 Me : 37 Lo : 32Heating

Silent mode sound pressure level —

Exterior dimensions (Height x Width x Depth) mm 210 × 1320 × 690

Exterior appearance( Munsell color )( RAL color )

Plaster white( 6.8Y8.9/0.2 ) near equivalent( RAL 9003 ) near equivalent

Net weight kg 33Heat exchanger Louver fin & inner grooved tubingFan type & Q'ty Centrifugal fan ×4Fan motor (Starting method) W 50 < Direct line start >

Air flowCooling

m3/min P-Hi : 20 Hi : 16 Me : 13 Lo : 10Heating

Available external static pressure Pa 0Outside air intake Not possibleAir filter, Quality / Quantity Pocket plastic net ×2(Washable)Shock & vibration absorber Rubber sleeve(for fan motor)Electric heater W —

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipmentsOverload protection for fan motor

Frost protection thermostat

Installationdata

Refrigerant piping size ( O.D. ) mmLiquid line: φ6.35 (1/4")Gas line: φ12.7 (1/2")

Connecting method Flare pipingAttached length of piping m —Drain hose Hose connectable VP20(O.D.26)

Drain pump, max lift height mm —IP number IPX0Standard accessories Mounting kit, Drain hoseOption parts Motion sensor : LB-E

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

Notes (1) The data are measured at the following conditions.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

Page 216: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 215 -

'19 • PAC-DB-308D

PFA004Z088 B

ModelItem FDE71VH

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 7.1Nominal heating capacity (range) kW 8.0

Sound power levelCooling

dB(A)

60Heating

Sound pressure levelCooling

P-Hi : 47 Hi : 41 Me : 37 Lo : 32Heating

Silent mode sound pressure level —

Exterior dimensions (Height x Width x Depth) mm 210 × 1320 × 690

Exterior appearance( Munsell color )( RAL color )

Plaster white( 6.8Y8.9/0.2 ) near equivalent( RAL 9003 ) near equivalent

Net weight kg 33Heat exchanger Louver fin & inner grooved tubingFan type & Q'ty Centrifugal fan ×4Fan motor (Starting method) W 50 < Direct line start >

Air flowCooling

m3/min P-Hi : 20 Hi : 16 Me : 13 Lo : 10Heating

Available external static pressure Pa 0Outside air intake Not possibleAir filter, Quality / Quantity Pocket plastic net ×2(Washable)Shock & vibration absorber Rubber sleeve(for fan motor)Electric heater W —

Operation control

Remote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-E-E3Room temperature control Thermostat by electronicsOperation display —

Safety equipmentsOverload protection for fan motor

Frost protection thermostat

Installationdata

Refrigerant piping size ( O.D. ) mmLiquid line: φ9.52 (3/8")Gas line: φ15.88 (5/8")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Drain hose Hose connectable VP20(O.D.26)

Drain pump, max lift height mm —IP number IPX0Standard accessories Mounting kit, Drain hoseOption parts Motion sensor : LB-E

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.(4) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

Notes (1) The data are measured at the following conditions.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

Page 217: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 216 -

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDC100VNA-W

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.)-11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.)-12.5(Max.)]

Sound power levelCooling

dB(A)

69Heating 70

Sound pressure levelCooling 54Heating 55

Silent mode sound pressure level 48/44 (Normal/Silent)

Exterior dimensions (Height × Width × Depth) mm 845×970×370

Exterior appearance( Munsell color )(RAL color)

Stucco white( 4.2Y7.5/1.1) near equivalent( RAL 7044 ) near equivalent

Net weight kg 77Compressor type & Q'ty RMT5126SWP3×1Compressor motor (Starting method) kW Direct line startRefrigerant oil (Amount, type) L 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Propeller fan ×1Fan motor (Starting method) W 86 < Direct line start >

Air flow Cooling

m3/min75

Heating 73Shock & vibration absorber Rubber sleeve (for fan motor & compressor)Electric heater W 20 (Crank case heater)

Safety equipmentsInternal thermostat for fan motor

Abnormal discharge temperature protection

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ9.52 (3/8") Gas line: φ15.88 (5/8")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50mVertical height diff. between O/U and I/U m Max.50m (Outdoor unit is higher) Max.15m (Outdoor unit is lower)Drain hose Hole size φ20 × 3 pcs

IP number IP24Standard accessories —Option parts —

Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) Slect the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

(2) Outdoor units

Page 218: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 217 -

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDC100VSA-W

Power source 3 Phase 380-415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 10.0 [ 4.0(Min.)-11.2(Max.)]Nominal heating capacity (range) kW 11.2 [ 4.0(Min.)-12.5(Max.)]

Sound power levelCooling

dB(A)

69Heating 70

Sound pressure levelCooling 54Heating 55

Silent mode sound pressure level 48/44 (Normal/Silent)

Exterior dimensions (Height × Width × Depth) mm 845×970×370

Exterior appearance( Munsell color )(RAL color)

Stucco white( 4.2Y7.5/1.1) near equivalent( RAL 7044 ) near equivalent

Net weight kg 78Compressor type & Q'ty RMT5126SWP4×1Compressor motor (Starting method) kW Direct line startRefrigerant oil (Amount, type) L 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Propeller fan ×1Fan motor (Starting method) W 86 < Direct line start >

Air flow Cooling

m3/min75

Heating 73Shock & vibration absorber Rubber sleeve (for fan motor & compressor)Electric heater W 20 (Crank case heater)

Safety equipmentsInternal thermostat for fan motor

Abnormal discharge temperature protection

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ9.52 (3/8") Gas line: φ15.88 (5/8")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50mVertical height diff. between O/U and I/U m Max.50m (Outdoor unit is higher) Max.15m (Outdoor unit is lower)Drain hose Hole size φ20 × 3 pcs

IP number IP24Standard accessories —Option parts —

Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) Slect the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

Page 219: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 218 -

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDC125VNA-W

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.)-14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.)-16.0(Max.)]

Sound power levelCooling

dB(A)

71Heating

Sound pressure levelCooling 54Heating 56

Silent mode sound pressure level 48/45 (Normal/Silent)

Exterior dimensions (Height × Width × Depth) mm 845×970×370

Exterior appearance( Munsell color )(RAL color)

Stucco white( 4.2Y7.5/1.1) near equivalent( RAL 7044 ) near equivalent

Net weight kg 77Compressor type & Q'ty RMT5126SWP3×1Compressor motor (Starting method) kW Direct line startRefrigerant oil (Amount, type) L 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Propeller fan ×1Fan motor (Starting method) W 86 < Direct line start >

Air flow Cooling

m3/min75

Heating 73Shock & vibration absorber Rubber sleeve (for fan motor & compressor)Electric heater W 20 (Crank case heater)

Safety equipmentsInternal thermostat for fan motor

Abnormal discharge temperature protection

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ9.52 (3/8") Gas line: φ15.88 (5/8")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50mVertical height diff. between O/U and I/U m Max.50m (Outdoor unit is higher) Max.15m (Outdoor unit is lower)Drain hose Hole size φ20 × 3 pcs

IP number IP24Standard accessories —Option parts —

Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) Slect the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

Page 220: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 219 -

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDC125VSA-W

Power source 3 Phase 380-415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 12.5 [ 5.0(Min.)-14.0(Max.)]Nominal heating capacity (range) kW 14.0 [ 4.0(Min.)-16.0(Max.)]

Sound power levelCooling

dB(A)

71Heating

Sound pressure levelCooling 54Heating 56

Silent mode sound pressure level 48/45 (Normal/Silent)

Exterior dimensions (Height × Width × Depth) mm 845×970×370

Exterior appearance( Munsell color )(RAL color)

Stucco white( 4.2Y7.5/1.1) near equivalent( RAL 7044 ) near equivalent

Net weight kg 78Compressor type & Q'ty RMT5126SWP4×1Compressor motor (Starting method) kW Direct line startRefrigerant oil (Amount, type) L 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Propeller fan ×1Fan motor (Starting method) W 86 < Direct line start >

Air flow Cooling

m3/min75

Heating 73Shock & vibration absorber Rubber sleeve (for fan motor & compressor)Electric heater W 20 (Crank case heater)

Safety equipmentsInternal thermostat for fan motor

Abnormal discharge temperature protection

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ9.52 (3/8") Gas line: φ15.88 (5/8")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50mVertical height diff. between O/U and I/U m Max.50m (Outdoor unit is higher) Max.15m (Outdoor unit is lower)Drain hose Hole size φ20 × 3 pcs

IP number IP24Standard accessories —Option parts —

Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) Slect the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

Page 221: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 220 -

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDC140VNA-W

Power source 1 Phase 220-240V 50Hz / 220V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.)-14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.)-16.5(Max.)]

Sound power levelCooling

dB(A)

72Heating 73

Sound pressure levelCooling 56Heating 58

Silent mode sound pressure level 49/45 (Normal/Silent)

Exterior dimensions (Height × Width × Depth) mm 845×970×370

Exterior appearance( Munsell color )(RAL color)

Stucco white( 4.2Y7.5/1.1) near equivalent( RAL 7044 ) near equivalent

Net weight kg 77Compressor type & Q'ty RMT5126SWP3×1Compressor motor (Starting method) kW Direct line startRefrigerant oil (Amount, type) L 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Propeller fan ×1Fan motor (Starting method) W 86 < Direct line start >

Air flow Cooling

m3/min75

Heating 73Shock & vibration absorber Rubber sleeve (for fan motor & compressor)Electric heater W 20 (Crank case heater)

Safety equipmentsInternal thermostat for fan motor

Abnormal discharge temperature protection

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ9.52 (3/8") Gas line: φ15.88 (5/8")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50mVertical height diff. between O/U and I/U m Max.50m (Outdoor unit is higher) Max.15m (Outdoor unit is lower)Drain hose Hole size φ20 × 3 pcs

IP number IP24Standard accessories —Option parts —

Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) Slect the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 230V 50Hz or 220V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

Page 222: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 221 -

'19 • PAC-DB-308D

PJF000Z589 B

ModelItem

FDC140VSA-W

Power source 3 Phase 380-415V 50Hz / 380V 60Hz

Operation data

Nominal cooling capacity (range) kW 13.6 [ 5.0(Min.)-14.5(Max.)]Nominal heating capacity (range) kW 15.5 [ 4.0(Min.)-16.5(Max.)]

Sound power levelCooling

dB(A)

72Heating 73

Sound pressure levelCooling 56Heating 58

Silent mode sound pressure level 49/45 (Normal/Silent)

Exterior dimensions (Height × Width × Depth) mm 845×970×370

Exterior appearance( Munsell color )(RAL color)

Stucco white( 4.2Y7.5/1.1) near equivalent( RAL 7044 ) near equivalent

Net weight kg 82Compressor type & Q'ty RMT5126SWP4×1Compressor motor (Starting method) kW Direct line startRefrigerant oil (Amount, type) L 0.9 (M-MB75)Refrigerant (Type, amount, pre-charge length) kg R32 3.3 in outdoor unit (Incl. the amount for the piping of 30m)Heat exchanger M shape fin & inner grooved tubingRefrigerant control Electronic expansion valveFan type & Q'ty Propeller fan ×1Fan motor (Starting method) W 86 < Direct line start >

Air flow Cooling

m3/min75

Heating 73Shock & vibration absorber Rubber sleeve (for fan motor & compressor)Electric heater W 20 (Crank case heater)

Safety equipmentsInternal thermostat for fan motor

Abnormal discharge temperature protection

Installation data

Refrigerant piping size ( O.D. ) mmLiquid line: φ9.52 (3/8") Gas line: φ15.88 (5/8")

Connecting method Flare pipingAttached length of piping m —Insulation for piping Necessary (both Liquid & Gas lines)Refrigerant line (one way) length m Max.50mVertical height diff. between O/U and I/U m Max.50m (Outdoor unit is higher) Max.15m (Outdoor unit is lower)Drain hose Hole size φ20 × 3 pcs

IP number IP24Standard accessories —Option parts —

Notes (1) The data are measured at the following conditions. The pipe length is 7.5m.

(2) This air-conditioner is manufactured and tested in conformity with the ISO.(3) Sound level indicates the value in an anechoic chamber. During operation these values are somewhat

higher due to ambient conditions.(4) Slect the breaker size according to the own national standard.(5) The operation data indicate when the air-conditioner is operated at 400V 50Hz or 380V 60Hz.

ItemOperation

Indoor air temperature Outdoor air temperatureStandards

DB WB DB WBCooling 27˚C 19˚C 35˚C 24˚C ISO5151-T1Heating 20˚C — 7˚C 6˚C ISO5151-H1

Page 223: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 222 -

'19 • PAC-DB-308D

Cooling power consumptionHeating power consumptionCooling running currentHeating running currentInrush current (L.R.A) <Max. running current>

(220-240V 50Hz/220V 60Hz)

Item Model FDC125VNA-W FDC140VNA-W

kW

A

A 5 <24>

FDC100VNA-W3.02/3.022.89/2.89

13.6-13.0/13.613.0-12.4/13.0

4.00/4.003.38/3.38

17.6-16.8/17.614.8-14.0/14.8

4.59/4.594.06/4.06

20.3-19.3/20.317.8-17.0/17.8

Cooling power consumptionHeating power consumptionCooling running currentHeating running currentInrush current (L.R.A) <Max. running current>

(380-415V 50Hz/380V 60Hz)

Item Model FDC100VSA-W FDC125VSA-W FDC140VSA-W

kW

A

A

3.02/3.022.89/2.89

4.5-4.3/4.54.3-4.1/4.3

4.00/4.003.38/3.38

5.9-5.6/5.95.0-4.7/5.0

5 <15>

4.59/4.594.06/4.066.8-6.4/6.86.0-5.7/6.0

(3) Operation chart The V Multi is a system that allows for different models and capacities of indoor units to be connected so the individual operating characteristics of the indoor and outdoor are provided. Use the procedure shown in item (c) to calculate the combined operating characteristics.

(a) Operating characteristic of outdoor unit

Note(1) This packaged air-conditioner is manufactured and tested in conformity with the following standard. ISO-T1 “UNITARY AIR-CONDITIONERS”

(b) Operating characteristic of indoor unit

Notes(1) This packaged air-conditioner is manufactured and tested in conformity with the following standard. ISO-T1 “UNITARY AIR-CONDITIONERS” Notes(2) The values shown in the above table are common to both cooling and heating operations.

ModelItem FDT50VH FDT60VH FDT71VH

Cooling power consumptionkW

0.04-0.04/0.04 0.07-0.07/0.07 0.08-0.08/0.08Heating power consumption 0.04-0.04/0.04 0.07-0.07/0.07 0.08-0.08/0.08Cooling running current

A0.36-0.33/0.36 0.62-0.57/0.62 0.70-0.64/0.70

Heating running current 0.36-0.33/0.36 0.62-0.57/0.62 0.70-0.64/0.70

FDT Series (220-240V 50Hz/220V 60Hz)

ModelItem FDE50VH FDE60VH FDE71VH

Cooling power consumptionkW

0.05-0.05/0.05 0.08-0.08/0.08Heating power consumption 0.05-0.05/0.05 0.08-0.08/0.08Cooling running current

A0.50-0.50/0.50 0.75-0.75/0.75

Heating running current 0.50-0.50/0.50 0.75-0.75/0.75

0.08-0.08/0.080.08-0.08/0.080.75-0.75/0.750.75-0.75/0.75

FDE Series (220-240V 50Hz/220V 60Hz)

Page 224: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 223 -

'19 • PAC-DB-308D

(c) Calculation of total operation characteristics Since the operation characteristics of V Multi system depend on combination of indoor unit, calculate the total operation characteristics of the system by using the formulas below according to speciations of each indoor unit or outdoor unit. (i) 1 Phase models 1) Total power consumption Total power consumption (kW) = Power consumption of outdoor unit + ∑ (Power consumption of indoor unit)

2) Total running current Total running current (A) = Running current of outdoor unit + ∑ (Running current of indoor unit)

3) Total power factor Total power factor (%) = [Total power consumption (W) / Total running current (A) × Power source] × 100

Total operation characteristics = Operation characteristic value of outdoor unit + Operation characteristic value of indoor unit

[Example]

(Conditions) Operation voltage ········· Indoor unit: 220 V, 50 Hz

Outdoor unit: 220 V, 50 Hz

Operation mode ··········· Cooling and Heating

Unit······························· Outdoor unit: FDC140VNA-W × 1 unit

Indoor unit: FDT71VH × 2 units

Item Model FDC140VNA-W FDT71VH

Operation characteristics of each unit (Cooling/Heating)

Power consumption (kW)

Running current (A)

0.08/0.08

0.70/0.70

4.59/4.06

20.3/17.8

① Total power consumption (kW)

(Cooling) 4.59 + (0.08 × 2) = 4.75

(Heating) 4.06 + (0.08 × 2) = 4.22

② Total running current (A)

(Cooling) 20.3 + (0.70 × 2) = 21.7

(Heating) 17.8 + (0.70 × 2) = 19.2

③ Total power factor (%)

(Cooling) × 100 = 99 %

(Heating) × 100 = 99 %

4.75 × 100021.7 × 220

4.22 × 100019.2 × 220

. .

. .

(ii) 3 Phase models 1) Total power consumption Total power consumption (kW) = Power consumption of outdoor unit + ∑ (Power consumption of indoor unit)

2) Total running current Total running current (A) = Running current of outdoor unit + [∑ (Running current of indoor unit) × 1/3]

3) Total power factor Total power factor (%) = [Total power consumption (W) / √ × Total running current (A) × Power source] × 100

Total operation characteristics = Operation characteristic value of outdoor unit + Operation characteristic value of indoor

unit

3

Page 225: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 224 -

'19 • PAC-DB-308D

[Example]

(Conditions) Operation voltage ········ Indoor unit: 220 V, 50 Hz

Outdoor unit: 380 V, 50 Hz

Operation mode ··········· Cooling and Heating

Unit······························· Outdoor unit: FDC125VSA-W × 1 unit

Indoor unit: FDT50VH × 1 unit, FDT71VH × 1 unit

Item Model FDC125VSA-W FDT50VH FDT71VH

Operation characteristics of each unit (Cooling/Heating)

Power consumption (kW)

Running current (A)

0.04/0.04

0.36/0.36

0.08/0.08

0.70/0.70

4.00/3.38

5.9/5.0

① Total power consumption (kW)

(Cooling) 4.00 + 0.04 + 0.08 = 4.12 (kW)

(Heating) 3.38 + 0.04 + 0.08 = 3.50 (kW)

② Total running current (A)

(Cooling) 5.9 + [(0.36 + 0.70) × )] = 6.3 (A)

(Heating) 5.0 + [(0.36 + 0.70) × )] = 5.4 (A)

31

③ Total power factor (%)

(Cooling) × 100 = 99 %

(Heating) × 100 = 98 %

4.12 × 10003 × 6.3 × 380

. .

. .

. .

. .

3.50 × 10003 × 5.4 × 380

31

Page 226: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

- 225 -

'19 • PAC-DB-308D

2.3 EXTERIOR DIMENSIONS (1) Indoor units (a) Ceiling cassette-4 way type (FDT) .............................................................See page 67 (b) Ceiling suspended type (FDE) ...................................................................See page 74 (2) Outdoor units .............................................................................................See page 79 (3) Remote control (Option parts) ...................................................................See page 80 2.4 ELECTRICAL WIRING (1) Indoor units (a) Ceiling cassette-4 way type (FDT) .........................................................See page 83 (b) Ceiling suspended type (FDE) ................................................................See page 89 (2) Outdoor units ..............................................................................................See page 92 2.5 TECHNICAL INFORMATION (1) Ceiling cassette-4 way type (FDT) ............................................................See page 118 (2) Ceiling suspended type (FDE) .................................................................See page 190

Page 227: DATA BOOKRemote control (Option) Wired : RC-EX3A , RC-E5 , RCH-E3 Wireless : RCN-T-5AW-E2 Room temperature control Thermostat by electronics Operation display — Safety equipments

HYPER INVERTER PACKAGED AIR-CONDITIONERS(Split system, Air to air heat pump type)

Twin type FDTC71VNXPVD FDTC100VNXPVD FDTC100VSXPVD FDTC125VNXPVD FDTC125VSXPVD

Triple type FDTC140VNXTVD FDTC140VSXTVD

CEILING CASSETTE- 4 WAY COMPACT TYPESingle type FDUM71VNXVD FDUM100VNXVD FDUM100VSXVD FDUM125VNXVD FDUM125VSXVD FDUM140VNXVD FDUM140VSXVD

Twin type FDUM100VNXPVD FDUM100VSXPVD FDUM125VNXPVD FDUM125VSXPVD FDUM140VNXPVD FDUM140VSXPVD

Triple type FDUM140VNXTVD FDUM140VSXTVD

DUCT CONNECTED-LOW/MIDDLE STATIC PRESSURE TYPE

Single type FDU71VNXVD FDU100VNXVD FDU100VSXVD FDU125VNXVD FDU125VSXVD FDU140VNXVD FDU140VSXVD

DUCT CONNECTED-HIGH STATIC PRESSURE TYPESingle type FDT71VNXVD FDT100VNXVD FDT100VSXVD FDT125VNXVD FDT125VSXVD FDT140VNXVD FDT140VSXVD

Twin type SRK100VNXPZIX SRK100VNXPZJX SRK100VSXPZIX SRK100VSXPZJX SRK125VNXPZIX SRK125VNXPZJX SRK125VSXPZIX SRK125VSXPZJX

Triple type SRK140VNXTZIX SRK140VNXTZJX SRK140VSXTZIX SRK140VSXTZJX

WALL MOUNTED TYPE

Twin type FDT71VNXPVD FDT100VNXPVD FDT100VSXPVD FDT125VNXPVD FDT125VSXPVD FDT140VNXPVD FDT140VSXPVD

Triple type FDT140VNXTVD FDT140VSXTVD

CEILING CASSETTE- 4 WAY TYPE

Single type FDEN71VNXVD FDEN100VNXVD FDEN100VSXVD FDEN125VNXVD FDEN125VSXVD FDEN140VNXVD FDEN140VSXVD

Twin type FDEN71VNXPVD FDEN100VNXPVD FDEN100VSXPVD FDEN125VNXPVD FDEN125VSXPVD FDEN140VNXPVD FDEN140VSXPVD

Triple type FDEN140VNXTVD FDEN140VSXTVD

CEILING SUSPENDED TYPE

Manual No. '10 • PAC - DB - 136

DATA BOOK

MICRO INVERTER PACKAGED AIR-CONDITIONERS

Air-Conditioning & Refrigeration Systems16-5, Konan 2-chome, Minato-ku, Tokyo, 108-8215 Japanhttp://www.mhi.co.jp

© Copyright MITSUBISHI HEAVY INDUSTRIES, LTD.

Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice.

DATA BOOK

Manual No. '09 • PAC - DB -136

DRAFTINVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS

HYPER INVERTER PACKAGED AIR-CONDITIONERS(Split system, Air to air heat pump type)

Single type FDT125VNXV 125VSXV 140VNXV 140VSXV

Twin type FDTC125VNXPVB 125VSXPVB

Triple type FDTC140VNXTVB 140VSXTVB

CEILING CASSETTE - 4WAY COMPACT TYPETwin type SRK125VNXPZIX 125VSXPZIX

Triple type SRK140VNXTZIX 140VSXTZIX

WALL MOUNTED TYPE

Twin type FDT125VNXPV 125VSXPV 140VNXPV 140VSXPV

Triple type FDT140VNXTV 140VSXTV

CEILING CASSETTE - 4WAY TYPE

Single type FDUM125VNXV 125VSXV 140VNXV 140VSXV

Twin type FDUM125VNXPV 125VSXPV 140VNXPV 140VSXPV

Triple type FDUM140VNXTV 140VSXTV

DUCT CONNECTED MIDDLE STATIC PRESSURE TYPE

Single type FDU125VNXV 125VSXV 140VNXV 140VSXV

DUCT CONNECTED HIGH STATIC PRESSURE TYPE

Single type FDEN125VNXV 125VSXV 140VNXV 140VSXV 125VNXVA 125VSXVA 140VNXVA 140VSXVA

Twin type FDEN125VNXPV 125VSXPV 140VNXPV 140VSXPV 125VNXPVA 125VSXPVA 140VNXPVA 140VSXPVA

Triple type FDEN140VNXTV 140VSXTV 140VNXTVA 140VSXTVA

CEILING SUSPENDED TYPE

Copyright MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD.Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice.

C

MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD.16-5 Konan 2-chome, Minato-ku, Tokyo, 108-8215, Japanhttp://www.mhi-mth.co.jp/en/