    The Quality Connection

    High Speed Cables

    or Enterprise Data Solutions

    Business Unit Telecom

  • 7/28/2019 data cables with drawings and charts

    2/16

    Enterprise Data Solutions (EDS)

    The escalating Internet data trac has stimulated anunprecedented growth in the communication data center

    inrastructure. Higher bandwidth networking protocols

    such as Ethernet and InniBand are evolving rapidly to

    support data rates o 40/100 Gb/s and 120 Gb/s respec-

    tively. Signicant changes in storage area networking

    (SAN) and high perormance computing (HPC) are trans-

    orming the cabling technology requirements or data

    centers and computer rooms.

    The cabling interconnect technology, materials and

    construction, plays an increasingly larger role in the

    achievable interconnect distances and cable manage-

    ment aspects or these high speed-high density data cen-

    ters, computer rooms, and equipment rooms. Network

    designers are struggling with critical path design choices.

    LEONIs EDS makes the right design choices possible.

    LEONI high speed parallel pair cables with LEONIsespecially ormulated dielectric enables a smaller cable

    diameter; reducing cable density and improving air fow

    and heat dissipation within servers and storage enclos-

    ures. LEONIZELL dielectrics oer signicantly lower loss

    and reduced time delay skew and amplitude skew over

    alternative materials.

    Due to their combined mechanical and electrical

    perormance, high speed cables rom LEONI are also

    deployed in mobile networks serving as high speed inter-

    connections between racks inside base stations.

    LEONIs ParaLinkcable product line is designed and

    oered to optimise the bandwidth cost ratio or a variety

    o high speed copper applications. ParaLinkhas esta-

    blished the benchmark or size, perormance, and cost

    over current data center product oerings.

    Due to its almost unique value added chain, LEONI is able

    to oer ber optic and data cables or EDS next to the

    Telecom business units ParaLinksolutions.

    Fast Cables. Quick Solutions.

    www.leoni-telecom.com

  • 7/28/2019 data cables with drawings and charts

    3/16

    Issue 11/2008

    All ParaLinkproducts are permanently enhanced

    or our customers. Thereore this brochure is subject

    to change and error. You will nd the updated status

    in our datasheets at www.leoni-telecom.com

    Features & Benefts 4

    10 GHz Operations 8

    5 GHz Operations 9

    3 GHz Operations 10

    3 GHz Fibre Channel 11

    5 GHz PCI Express 12

    10 GHz PCI Express 13

    Measuring Laborator y 14

    The Quality Connection Worldwide 15

    Contents

    LEONI is a member

    o the ollowing organisations:

    LEONI 3

  • 7/28/2019 data cables with drawings and charts

    4/16

    ParaLinkFeatures and Benets

    Outside diameter < 15 %

    increased cooling/airfow

    Mode conversion excellent

    reduces common mode propagations

    Insertion loss 15 20% improvementequals longer distance

    Skew

  • 7/28/2019 data cables with drawings and charts

    5/16

    Dielectric Technologies

    LEONIZELL unique gas injection skin-oam-skin dielectric technology

    has been specically developed or the ParaLinkhigh speed dieren-

    tial pair product line. The LEONIZELL structure oers a very rugged

    and stable mechanical structure with the ollowing advantages and

    benets compared to legacy industry structures:

    Maximum adhesion to the inner conductor

    limits pistoning eects with cable fexure

    minimises shrink back eects

    o the dielectric during termination (soldering / welding)

    eliminates air voids close to the center conductor

    prevents instable electrical perormance

    Resilience to mechanical deormations

    minimises perormance degradation during and ater installation

    eliminates insertion loss suck-outs caused by bending and fexure

    ensures predictable perormance even ater severe abuse

    Colour coding

    enables an easy termination

    enables orientation o the conductors within the pair

    elimination o perormance degradation due to pigmentation

    within dielectric technologies

    Cabling Technologies

    The unique cabling technology used in the ParaLinkmanuacturing

    process oers signicant space savings and a reduction o the outer

    cable diameter, in most cases up to 15 % and even as much as 20 %

    compared to conventional cabling technologies. The ParaLinkunilay

    cable lay-up prevents mechanical deormation o the dierential pair

    at the same time as reducing the eect o compression on dierential

    pairs. Thereore it minimises negative infuences on the transmission

    line and

    improves the transmission lines signal integrity.

    reduces the cables outer diameter

    (i.e. 4XAWG26 diameter is equal to that o many

    competitors 4XAWG28).

    simplies routing and cable management.enables smaller and tighter bending radii.

    increases cable densities.

    reduces weight.

    reduces pistoning eects.

    100 %

    Par aL i n k r educes pi sto n in g eects co m par ed to r equen t h i gh speed cabl es .

    Comparison LEONIZELL and requent dielectric. ParaLink diameter compared to requently used high speed cable diameter.

    LEONIZELL commonly used

    dielectric technology

    LEONI 5

  • 7/28/2019 data cables with drawings and charts

    6/16

    0 2000 4000 6000 8000 10000 12000 14000 16000 180000.00

    1.00

    2.00

    3.00

    4.00

    5.00

    6.00

    Insertion Loss Deviation

    SDD21/dB

    /MHz 0 5108 1109 1.5109 2109 2.5109 3109 3.5109 4109 4.5109 5109

    0

    10

    20

    30

    40

    50

    60

    /MHz

    Mode Conversion IL with Mode Conversion IL ideal

    Sxy21/dB

    Infuence o mode conversion on the insertion loss

    min.

    max.

    ParaLinkUnique Perormance

    The variation o insertion loss (ILV) measures the dierences o inser-

    tion loss between channels or pairs. Certain actor, or example return

    loss, mode conversion, impedance, dimensions o cable, insulation

    materials have an infuence on the pair insertion loss (IL). I the IL

    between all pairs o a cable varies in a small range (typ. less than

    5 % with ParaLink) the quality o the cable is high and the channel

    perormance is predictable.

    Mode Conversion (SCDxy) describes the relationship between trans-

    mitted dierential mode signal energy at one end o the cable to the

    received common mode energy at the other end. It is measured in the

    requency domain. The eect o mode conversion (MC) is additional

    insertion loss and it occurs mostly due to asymmetry between both

    signal wires o a pair. In time domain this eect is well known as intra

    pair skew, a time delay between both signal parts at 50 % o the sig-

    nal step. Measuring the mode conversion o a cable has the advantageagainst skew measurements, that the losses o the dierential signal

    or dierent data rates (= dierent requency bandwidths) will be

    visible.

    Examples or Mode Conversion:

    Insertion Loss Variation (ILV) Mode Conversion

    Ideal cable: A symmetric dierential signal is transmitted into a cable

    without loss. Tx+(t) = Tx-(t)

    At the receiving end the dierential mode signal has twice the height

    o the signal parts Tx+ and Tx-. In this case a common mode signal

    does not exist.

    Tx+

    Tx

    Tx Rx

    Rx di = Rx+ - Rx

    Rx comm = Rx+ + Rx

    Transmission o an ideal cable

    6 LEONI

  • 7/28/2019 data cables with drawings and charts

    7/16

    0 5108 1109 1.5109 2109 2.5109 3109 3.5109 4109 4.5109 5109

    0

    10

    20

    30

    40

    50

    60

    /MHz

    Mode Conversion IL with Mode Conversion IL ideal

    Sxy21/dB

    Sxy21/dB

    0 5108 1109 1.5109 2109 2.5109 3109 3.5109 4109 4.5109 5109

    0

    10

    20

    30

    40

    50

    60

    /MHz

    Mode Conversion IL with Mode Conversion IL ideal

    Bad CableParaLink

    I the cable is almost absolutely symmetric, both transmitted signal

    parts arrive simultaneously with the same (opposite) amplitude atten-

    uated at the receiving end o the cable. Because Rx+(t) signal is close

    to Rx-(t) signal, the common mode signal is still very low.

    Due to dierent lengths o the wires within the shielded pair, the posi-

    tive signal part o the dierential signal arrives at the receiving end o

    the cable at a dierent time compared to the negative part. The Rx+(t)

    signal is not equal to -Rx-(t) any more. A common mode signal arises.

    At the same time the dierential mode signal energy decreases.

    Rx+

    Rx

    Tx Rx

    Rx di = Rx+ - Rx

    Rx comm = Rx+ + Rx

    Tx+

    Tx

    Tx+

    Tx

    Tx Rx

    Rx di = Rx+ - Rx

    Rx comm = Rx+ + Rx

    Rx+

    Rx

    Skew

    Common Mode Energie

    Jitt er: T he mom ent

    at which the signal

    changes are getting

    indeterminate.

    LEONI 7

  • 7/28/2019 data cables with drawings and charts

    8/16

    100 900 1700 2500 3300 4100 4900 5700 6500 7300 8100 890 0 9700 10000

    0

    1

    2

    3

    4

    5

    6

    7

    8

    MHz

    a/(dB/m)

    Insertion loss

    24 AWG26 AWG

    28 AWG

    30 AWG

    32 AWG

    * InfniBand is a registered t rademark o the InfniBand Trade Association.

    ParaLink11

    Guarantees swept perormance up to 10 GHz

    Form Factor 1X 4X 10X 12X

    32 AWG L45468-J11-C245 (PVC)

    L45468-J11-C246 (LSZH)

    L45468-J411-C215 (PVC)

    L45468-J411-C216 (LSZH)

    L45468-J1211-C55 (PVC)

    L45468-J1211-C56 (LSZH)

    30 AWG L45468-J12-C245 (PVC)

    L45468-J12-C246 (LSZH)

    L45468-J412-C215 (PVC)

    L45468-J412-C216 (LSZH)

    L45468-J1012-C55 (PVC)

    L45468-J1012-C56 (LSZH)

    L45468-J1212-C55 (PVC)

    L45468-J1212-C56 (LSZH)

    28 AWG L45468-J13-C245 (PVC)

    L45468-J13-C246 (LSZH)

    L45468-J413-C215 (PVC)

    L45468-J413-C216 (LSZH)

    L45468-J1013-C55 (PVC)

    L45468-J1013-C56 (LSZH)

    L45468-J1213-C55 (PVC)

    L45468-J1213-C56 (LSZH)

    26 AWG L45468-J14-C245 (PVC)

    L45468-J14-C246 (LSZH)

    L45468-J414-C215 (PVC)

    L45468-J414-C216 (LSZH)

    L45468-J1014-C55 (PVC)

    L45468-J1014-C56 (LSZH)

    L45468-J1214-C55 (PVC)

    L45468-J1214-C56 (LSZH)

    24 AWG L45468-J15-C245 (PVC)

    L45468-J15-C246 (LSZH)

    L45468-J415-C215 (PVC)

    L45468-J415-C216 (LSZH)

    L45468-J1015-C55 (PVC)

    L45468-J1015-C56 (LSZH)

    L45468-J1215-C55 (PVC)

    L45468-J1215-C56 (LSZH)

    Application

    ParaLink11 is designed or dierential I/O interconnections in servers,

    routers, switches, storage systems and any application with theoretical

    data transmission speeds o up to 20 Gb/s per channel.

    Mechancial properties

    Bending radius Due to the extreme durability o the special materi-

    als and the unique cable geometry the cables can

    withstand multiple fexure over a small bending

    radius.

    Fire perormance Due to an outer jacket, which is available with halo-

    gen and lead-ree propietary elastomer, the cable is

    certied according to UL 13 CL2 in compliance with

    CSA FT4 and thereore is tested according to UL

    1685 and IEC 60332-3-24.

    Electrical properties

    Impedance 100 Ohm

    Insertion loss Up to 15 % lower than the industry average

    Skew Conductor to conductor

    100 ps/10 m (3 ps/t)

    Pair to pair

    400 ps/10 m (12 ps/t)

    ILV max. +/ 5%

    *HSSG = High Speed Study Group

    EA QSFP MGInfniBand*

    HSSG*(IEEE)

    SFP+

    8 LEONI

  • 7/28/2019 data cables with drawings and charts

    9/16

    100 900 1700 2500 3300 4100 4900 5000

    0

    1

    2

    3

    4

    MHz

    a/(dB/m)

    Insertion loss

    24 AWG26 AWG

    28 AWG

    30 AWG

    ParaLink5

    Guarantees swept perormance up to 5 GHz

    Form Factor 1X 4X 12X

    30 AWG L45468-J12-C25 (PVC)

    L45468-J12-C26 (LSZH)

    L45468-J412-C15 (PVC)

    L45468-J412-C16 (LSZH)

    L45468-J1212-C5 (PVC)

    L45468-J1212-C6 (LSZH)

    28 AWG L45468-J13-C25 (PVC)

    L45468-J13-C26 (LSZH)

    L45468-J413-C15 (PVC)

    L45468-J413-C16 (LSZH)

    L45468-J1213-C15 (PVC)

    L45468-J1213-C16 (LSZH)

    26 AWG L45468-J14-C75 (PVC)

    L45468-J14-C76 (LSZH)

    L45468-J414-C115 (PVC)

    L45468-J414-C116 (LSZH)

    L45468-J1214-C85 (PVC)

    L45468-J1214-C86 (LSZH)

    24 AWG L45468-J15-C45 (PVC)

    L45468-J15-C46 (LSZH)

    L45468-J415-C25 (PVC)

    L45468-J415-C26 (LSZH)

    L45468-J1215-C25 (PVC)

    L45468-J1215-C26 (LSZH)

    Application

    ParaLink5 is designed or dierential I/O interconnections in servers,

    routers, switches, storage systems and any application with theoreti-

    cal data transmission speeds o up to 8 Gb/s per channel.

    Mechancial properties

    Bending radius Due to the extreme durability o the special materi-

    als and the unique cable geometry the cables can

    withstand multiple fexure over a small bending

    radius.

    Fire perormance Due to an outer jacket, which is available with halo-

    gen and lead-ree propietary elastomer, the cable is

    certied according to UL 13 CL2 in compliance with

    CSA FT4 and thereore is tested according to UL

    1685 and IEC 60332-3-24.

    Electrical properties

    Impedance 100 Ohm

    Insertion loss Up to 15 % lower than the industry average

    Skew Conductor to conductor

    200 ps/10 m (6 ps/t)

    Pair to pair

    500 ps/10 m (15 ps/t)

    ILV max. +/ 5 %

    QSFP MGHSSG(IEEE)

    SFPInfniBand

    SAS2

    LEONI 9

  • 7/28/2019 data cables with drawings and charts

    10/16

    100 900 1700 2500 3000

    0

    1

    2

    3

    4

    MHz

    a/(dB/m)

    Insertion loss

    24 AWG26 AWG

    28 AWG

    30 AWG

    Form Factor 1X 4X 8X 12X

    30 AWG L45468-J12-C15 (PVC)

    L45468-J12-C16 (LSZH)

    L45468-J412-C25 (PVC)

    L45468-J412-C26 (LSZH)

    L45468-J812-C15 (PVC)

    L45468-J812-C16 (LSZH)

    L45468-J1212-C25 (PVC)

    L45468-J1212-C26 (LSZH)

    28 AWG L45468-J13-C45 (PVC)

    L45468-J13-C46 (LSZH)

    L45468-J413-C25 (PVC)

    L45468-J413-C26 (LSZH)

    L45468-J813-C5 (PVC)

    L45468-J813-C6 (LSZH)

    L45468-J1213-C25 (PVC)

    L45468-J1213-C26 (LSZH)

    26 AWG L45468-J14-C65 (PVC)

    L45468-J14-C66 (LSZH)

    L45468-J414-C35 (PVC)

    L45468-J414-C36 (LSZH)

    L45468-J814-C5 (PVC)

    L45468-J814-C6 (LSZH)

    L45468-J1214-C25 (PVC)

    L45468-J1214-C26 (LSZH)

    24 AWG L45468-J15-C95 (PVC)

    L45468-J15-C96 (LSZH)

    L45468-J415-C65 (PVC)

    L45468-J415-C66 (LSZH)

    L45468-J815-C5 (PVC)

    L45468-J815-C6 (LSZH)

    L45468-J1215-C15 (PVC)

    L45468-J1215-C16 (LSZH)

    ParaLink3

    Guarantees swept perormance up to 3 GHz

    Application

    ParaLink-3 is designed or dierential I/O interconnections in servers,

    routers, switches, storage systems and any application with theoreti-

    cal data transmission speeds o up to 5 Gb/s per channel.

    Mechancial properties

    Bending radius Due to the extreme durability o the special materi-

    als and the unique cable geometry the cables can

    withstand multiple fexure over a small bending

    radius.

    Fire perormance Due to an outer jacket, which is available with halo-

    gen and lead-ree propietary elastomer, the cable is

    certied according to UL 13 CL2 in compliance with

    CSA FT4 and thereore is tested according to UL

    1685 and IEC 60332-3-24.

    Electrical properties

    Impedance 100 Ohm

    Insertion loss Up to 15 % lower than the industry average

    Skew Conductor to conductor

    200 ps/10 m (6 ps/t)

    Pair to pair

    500 ps/10 m (15 ps/t)

    ILV max. +/ 5 %

    eSATA SAS SFPEAInfniBand

    FCIA HSSDCII MG

    10 LEONI

  • 7/28/2019 data cables with drawings and charts

    11/16

    100 900 1700 2500 3000

    0

    1

    2

    3

    4

    MHz

    a/(dB/m)

    Insertion loss

    24 AWG26 AWG

    28 AWG

    30 AWG

    ParaLink3or Fibre Channel

    Guarantees swept perormance up to 3 GHz

    Application

    ParaLinkor Fibre Channel is designed or dierential I/O interconnec-

    tions in servers, routers, switches, storage systems and any application

    with theoretical data transmission speeds o up to 8 Gb/s per channel

    at 150 Ohm.

    Mechancial properties

    Bending radius Due to the extreme durability o the special materi-

    als and the unique cable geometry the cables can

    bear up against extreme fexure and small bending

    radius.

    Fire perormance Due to an outer jacket, which is available with halo-

    gen and lead-ree propietary elastomer, the cable is

    certied according to UL 13 CL2 in compliance with

    CSA FT4 and thereore is tested according to UL

    1685 and IEC 60332-3-24.

    Electrical properties

    Impedance 150 Ohm

    Insertion loss Up to 15 % lower than the industry average

    Skew Conductor to conductor

    200 ps/10 m (3 ps/t)

    Pair to pair

    500 ps/10 m (12 ps/t)

    ILV max. +/ 5 %

    Form Factor 1X

    28 AWG L45468-G12-C5 (PVC)

    L45468-G12-C6 (LSZH)

    26 AWG L45468-G14-C5 (PVC)

    L45468-G14-C6 (LSZH)

    24 AWG L45468-G15-C5 (PVC)

    L45468-G15-C6 (LSZH)

    22 AWG L45468-G16-C5 (PVC)

    L45468-G16-C6 (LSZH)

    HSSDCII MGFCIA

    LEONI 11

  • 7/28/2019 data cables with drawings and charts

    12/16

    ParaLink5or PCI Express

    with sideband signalling

    Guarantees swept perormance up to 5 GHz

    Application

    ParaLink or PCI express is designed or dierential I/O interconnec-

    tions in servers, routers, switches, storage systems and any application

    with theoretical data transmission speeds o up to 5 Gb/s per channel.

    Side band and clock pair (28 AWG) are available with power con-

    ductors.

    Mechancial properties

    Bending radius Due to the extreme durability o the special materi-

    als and the unique cable geometry the cables can

    bear up against extreme fexure and small bending

    radius.

    Fire perormance Due to an outer jacket, which is available with halo-

    gen and lead-ree propietary elastomer, the cable is

    certied according to UL 13 CL2 in compliance with

    CSA FT4 and thereore is tested according to UL

    1685 and IEC 60332-3-24.

    Electrical properties

    Impedance 100 Ohm

    Insertion loss Up to 15 % lower than the industry average

    Skew Conductor to conductor

    200 ps/10 m (3 ps/t)

    Pair to pair

    500 ps/10 m (12 ps/t)

    ILV max. +/ 5 %

    Form Factor 4X

    30 AWG L45468-J712-C45 (PVC)

    L45468-J712-C46 (LSZH)

    28 AWG L45468-J713-C45 (PVC)L45468-J713-C46 (LSZH)

    26 AWG L45468-J714-C45 (PVC)

    L45468-J714-C46 (LSZH)

    24 AWG L45468-J715-C45 (PVC)

    L45468-J715-C46 (LSZH)

    IPass is a registered trademark o molex

    IPASSGEN 2PCIExpress

    e.g. L45468-J715-C45 & L45468-J715-C46

    100 900 1700 2500 3300 4100 4900 5000

    0

    1

    2

    3

    4

    a/(dB/m)

    Insertion loss

    24 AWG26 AWG

    28 AWG

    30 AWG

    MHz

    12 LEONI

  • 7/28/2019 data cables with drawings and charts

    13/16

    IPASSGEN 3PCIExpress

    ParaLink11or PCI Express

    with sideband signalling

    Guarantees swept perormance up to 10 GHz

    Application

    ParaLink11 or PCI express is designed or dierential I/O interconnec-

    tions in servers, routers, switches, storage systems and any application

    with theoretical data transmission speeds o up to 8 Gb/s per channel.

    Side band and clock pair (28 AWG) are available with power con-

    ductors.

    Mechancial properties

    Bending radius Due to the extreme durability o the special materi-

    als and the unique cable geometry the cables can

    bear up against extreme fexure and small bending

    radius.

    Fire perormance Due to an outer jacket, which is available with halo-

    gen and lead-ree propietary elastomer, the cable is

    certied according to UL 13 CL2 in compliance with

    CSA FT4 and thereore is tested according to UL1685 and IEC 60332-3-24.

    Electrical properties

    Impedance 100 Ohm

    Insertion loss Up to 15 % lower than the industry average

    Skew Conductor to conductor

    200 ps/10 m (3 ps/t)

    Pair to pair

    500 ps/10 m (12 ps/t)

    ILV max. +/ 5 %

    Form Factor 4X

    30 AWG L45468-J712-W215 (PVC)

    L45468-J712-W216 (LSZH)

    28 AWG L45468-J713-W215 (PVC)

    L45468-J713-W216 (LSZH)

    26 AWG L45468-J714-W215 (PVC)

    L45468-J714-W216 (LSZH)

    24 AWG L45468-J715-W215 (PVC)

    L45468-J715-W216 (LSZH)

    100 900 1700 2500 3300 4100 4900 5700 6500 7300 8100 890 0 9700 10000

    0

    1

    2

    3

    4

    5

    6

    7

    8

    MHz

    a/(dB/m)

    Insertion loss

    24 AWG26 AWG

    28 AWG

    30 AWG

    e.g. L45468-J714-W215 & L45468 -J714-W216

    LEONI 13

  • 7/28/2019 data cables with drawings and charts

    14/16

    LEONI Measuring Laboratory

    The measuring laboratory o the LEONI Business Unit Telecom isintended to unction as a research and development lab. It will also

    provide quality assurance or manuacturing high-speed cables or

    high-bandwidth/requency applications.

    A ully air-conditioned, antistatic environment and proper measu-

    rement xture methods have been created and developed to ensure

    the accuracy, calibration and repeatability o testing activities. The test

    lab is equipped with state-o-the-art network analyzers rom Agilent

    Technologies, enabling tests or dierential transmission lines in re-

    quencies up to 50 GHz.

    Two 4 port network analyzers (4x 50 Ohm or 2x 100 Ohm) equipped

    with the newest PLTS (Physical Layer Test System) sotware avoid the

    need or transormers, thus providing accurate measurements o the

    transmission line.

    Traditional measuring transormers must be used with an impe-

    dance matching the impedance or the transmission line, usually about

    100 Ohm or InniBand and 150 Ohm or Fibre Channel applications.

    They are limited in the measurement o high requencies and cannot

    measure mode conversion. This makes it virtually impossible to take

    accurate measurements in the bandwidth o interest or the high-

    perormance transmission line applications mentioned above.

    The lab is also equipped with two Tektronix TDA or time domainmeasurements, such as time delay, skew, impedance and distance

    to ault, which can also be determined in the requency domain

    using network analyzers. However, using network analyzers requires

    signicant margins o error in mathematical transormations rom

    requency to time domain.

    The LEONI signal integrity development laboratory has extensive

    proprietary sotware at disposal to model, simulate and emulate all

    perormance aspects o the signal integrity o a given dierential

    transmission line, including SPICE and eField models. That, combinded

    with 12,5 GB/s Advantest pulse pattern generators, provides LEONI

    with a solid engineering base to aid and accelerate customer develop-

    ment programs.

    Foto: Agilent Technologies

    Foto: D3186 rom Advantest

    14 LEONI

  • 7/28/2019 data cables with drawings and charts

    15/16

    LEONI quality managementA consistently high level o quality is vital or our products.

    This means that the entire process at LEONI rom a products plan-

    ning to its completion is constantly monitored. Our quality man-

    agement system is certied in accordance with DIN/ISO 9001:2000

    and is updated permanently.

    Environment-riendly and sae

    O course, halogen-ree versions o a great number o the cables in

    our range are also available. This does reduce the strain in the envi-

    ronment, it also means less smoke and corrosive emissions in case

    o a re or your saety.

    LEONI environmental management

    For us, business success with ecological responsibility is not a con-

    tradiction in terms. Because o this, environmental protection is an

    intrinsic element o our corporate activities. Our environment man-

    agement system is certied as complying with DIN EN ISO 14001,

    conrming that our environment policy is eectively implemented.

    The Quality ConnectionWorldwide

    Please fnd your sales contact at www.leoni-telecom.com/sales