Speedor Storm Speedor Storm Speedor Storm Speedor Storm is a new model from the family of Speedor high speed energy saving industrial doors, designed for frequent use on exposed external openings: Warehouses Refuse / Waste Plants, EfW, Grain tipping bays AD Facilities Factories Distribution stores Ports Large wind exposed areas Main features include unique guide system offering exceptional wind resistance, reliable and clean inline drive system complete with integral safety brake and variable speed operation. Benefits include reduced heat loss, odour control, vermin control, refuse containment and safety control. Redburn Road, Westerhope Industrial Estate, Newcastle upon Tyne, NE5 1PJ, UK. T: +44 (0) 191 214 0404 F: +44 (0) 191 271 1611 E: [email protected] www.hartdoors.com DATA SHEET 109 V8

Upload: others

Post on 25-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Speedor Storm Speedor Storm Speedor Storm Speedor Storm is a new model from the family of Speedor high speed energy saving industrial

    doors, designed for frequent use on exposed external openings:

    • Warehouses • Refuse / Waste Plants, EfW, Grain tipping bays • AD Facilities • Factories • Distribution stores • Ports • Large wind exposed areas

    Main features include unique guide system offering exceptional wind resistance, reliable and

    clean inline drive system complete with integral safety brake and variable speed operation.

    Benefits include reduced heat loss, odour control, vermin control, refuse containment and safety

    control.

    Redburn Road, Westerhope Industrial Estate, Newcastle upon Tyne, NE5 1PJ, UK.

    T: +44 (0) 191 214 0404 F: +44 (0) 191 271 1611

    E: [email protected] www.hartdoors.com

    DA

    TA

    SH

    EE

    T 1

    09

    V8

  • Call us to see how we can help. Telephone 0191 214 0404

    Induction Loop Movement SensorsPhotocells Push Button

    Wind Resistance Class 3Wind Resistance Class 3Wind Resistance Class 3Wind Resistance Class 3----5 optional5 optional5 optional5 optional Bracing with wind lock guide and pairs of roller bearings is tested to one

    tonne loading. Wind loading is dependant on door size and the quantity of

    horizontal wind bracing across the width of the door. Wind resistance

    standard BS:EN:12424 details levels from class 0 to class 5 tested in the door

    closed position. Small Speedor Storms can

    be designed to achieve class 5 whilst larger

    Speedors Storms with similar structure will

    achieve class 3. When deciding on the wind class

    requirement, it is important to fully consider

    the unique environment each door system

    is to be installed within and the implications

    of building layouts, sizes and the possible

    resultant pressures on the door system.

    Contact us for clarification and more details.

    Fabric:Fabric:Fabric:Fabric: Multilayer PVC and textile which combine to ensure excellent strength, tear

    resistance and long life. The curtain has very good isolation properties, highly

    scratch resistance and is easy to clean. Curtain braces are fixed horizontally

    within a contrasting PVC pocket which not only offer further strengthening and

    wind resistance, but also add to visual appearance of the door system.

    Optional transparent vision panel available.

    Standards:Standards:Standards:Standards: The machinery directive safety in use of power operated doors BS EN 12453 &

    12444 and safety devices for power operated doors BSEN 12978.

    Requirements for the safe installation and use PREN 12625. Third party

    certified Quality system ISO 9001 is in operation.

    Installation:Installation:Installation:Installation: Hart will do it all, whatever you require, we will work with your contractor or

    undertake the entire preparation, specialist bracketry and installation,

    including electrical work. All works will be completed to ISO 9002. which

    includes IEE regulations.

    Operators and options:Operators and options:Operators and options:Operators and options:

    System operators are used to open the door, they include

    induction floor loops, photo cells, radar, hand held or vehicle

    mounted radio transmitters, press buttons or pull cords. Any

    of these operators can be used individually or in parallel.

    They can be used to exclude pedestrians, be a security

    barrier or open for all. Please Note: Major benefits come

    with full automatic door by providing efficient throughput of

    vehicles and staff whilst giving major energy savings and

    environmental improvements.

    Size Availability:Size Availability:Size Availability:Size Availability: All doors are made to measure to specific requirements. Up 8 metres Up 8 metres Up 8 metres Up 8 metres in

    width or height providing a maximum surface area of 48 sq meters is

    complied with.

    Visit www.hartdoors.com to see our full range of products

    Movement Sensors Radio activated Pull Cords

    Control Panel:Control Panel:Control Panel:Control Panel: The control panel has been designed to provide for all conceivable options

    required for automatic door operations and interface with vehicles, specialist

    equipment including conveyors.

    Various control panel upgrades are available to suit client interfacing and

    requirements

    Door drive and Speeds:Door drive and Speeds:Door drive and Speeds:Door drive and Speeds: The highly rated direct shaft drive with built

    on frequency inverter. Anti-fall protection

    to BS:EN12453:2001. Variable Speed

    options from 0.5mps up to 1.5mps.

    Special environment options including

    IP65i drives and heated insulated covers to

    prevent moisture build up.

    Metal Hoods Covers and Infill's:Metal Hoods Covers and Infill's:Metal Hoods Covers and Infill's:Metal Hoods Covers and Infill's: Barrel Hood, Motor Hood and Infills can be supplied as optional items depending

    on requirements. Available in galvanised sheet or powder coated steel.

    Insulated and heated motor hood options also available.

    Safety Systems and HSE requirements:Safety Systems and HSE requirements:Safety Systems and HSE requirements:Safety Systems and HSE requirements: Standard: Standard: Standard: Standard: The standard door system includes a pressure sensitive edge on the

    leading edge of the door, which will stop and reverse the door to the fully open

    position if contacted. This system is complemented with a safety photocell

    which is mounted within the door frame 875mm from finished floor level.

    UpUpUpUp----Grade option: Grade option: Grade option: Grade option: -The light curtain safety system upgrade uses category E

    safety light curtain within an IP67 enclosure which protects the required area

    under the door system to conform to BSEN12453:2001 and ensures a

    contactless safety system.

    Good practiseGood practiseGood practiseGood practise: - we recommend that forward warning photocells fitted between

    600mm and 750mm in advance of the door are fitted to both sides of the door

    to act as further safety if pedestrians are to use the doorway.

    Further options include traffic or warning lights, Klaxons, presence or movement

    detection systems.

    Seals:Seals:Seals:Seals: An optional deep brush seal is mounted across the head of the door above the

    clear opening. A PVC extrusion is fitted to the bottom rail over the rubber draught

    seal to minimise floor deviations.

    Other options:Other options:Other options:Other options:

    • Clear Vision Panel • Barrel / Motor Covers • Safety Light curtain • Traffic Lights • Battery back up • Audible warnings • Part open facility

    • Low level hand chain • Airlock facility with other

    doors

    • Atex rated • IP65 Specifications • Alarm if door left open after

    set amount of time.

    Safety Light Curtain

  • Redburn Road, Westerhope Industrial Estate, Newcastle upon Tyne, NE5 1PJ, UK.

    T: +44 (0) 191 214 0404 F: +44 (0) 191 271 1611

    E: [email protected] www.hartdoors.com

    DA

    TA

    SH

    EE

    T 1

    09

    Power RequirementsPower RequirementsPower RequirementsPower Requirements

    3 phase neutral and earth supply terminated in a 16 amp socket (5-pin) in accordance with IEC 60309-2. The socket is to be positioned at low level (approx 1.5 metre from floor). 240V single phase option available on selected

    sizes— contact us for more information.

    Architects ShortformArchitects ShortformArchitects ShortformArchitects Shortform

    Speedor Storm high speed door complete with heavy duty fabric, wind bracing with roller restrictors, aluminium bottom rail, high speed operation, powder coated side guides, top and bottom seals, inverter direct drive complete with safety brake, unique control panel, safety

    photocell and bottom edge.

    Operator options:Operator options:Operator options:Operator options:

    Induction floor loop, Movement sensor, photocell operators, pull cords, push buttons, radio operation. Specialist controls for integration to

    building management systems.

    Optional items:Optional items:Optional items:Optional items:

    Hood and motor hood, additional wind bracing, vision panel, breakaway bottom rail, audio/visual devices, airlock/interlocking and optional upgrade

    to safety light curtain.

    Features and AppearanceFeatures and AppearanceFeatures and AppearanceFeatures and Appearance

    Door sizesDoor sizesDoor sizesDoor sizes Up to 6m wide x 8m high or 8m wide x 6m high.

    (max area 48 sq. meters)

    Door applicationsDoor applicationsDoor applicationsDoor applications Warehouse, Factories, Distribution stores, waste facilities,

    AD facilities, EfW, large exposed openings.

    Colour availabilityColour availabilityColour availabilityColour availability

    RAL 2002 Red—Subject to availability

    RAL 6002 Olive Green—Subject to availability

    Other colours available on request.

    Safety optionsSafety optionsSafety optionsSafety options Optical touch sensitive safety bottom edge, safety

    photocells, non-contact safety light curtain, movement

    sensors, presence sensors and laser detection.

    Curtain optionsCurtain optionsCurtain optionsCurtain options Clear vision panels, logo / images on curtain.

    HoodsHoodsHoodsHoods Optional, hoods with rounded edges or water slopes to

    hoods for external.

    Door speedsDoor speedsDoor speedsDoor speeds Standard variable speed up to 1.3m /sec opening

    speed and 0.4m /sec closing speed at 2.5m from finished

    floor level. Higher or slower speed options upon request.

    AutomationAutomationAutomationAutomation Full or partial automation vehicle or pedestrian

    Wind ResistanceWind ResistanceWind ResistanceWind Resistance Up to class 5 in the closed position dependant on size.

    Doors should not be operated in extreme wind conditions.

    Typical General layout drawing of steelwork requirements

    RAL 5013 RAL 1018