U.I. Lapp GmbH DATA SHEET ÖLFLEX ® SOLAR XLR WP DB 1023501EN valid from: 22.04.2015 Originator: A. Terpe / PCM approved: PDC Document: DB1023501EN page 1 of 2 All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34. PD 0019/2.1_11.09EN 1. Application ÖLFLEX ® SOLAR XLR WP cables are weather-, abrasion- and UV-resistant photovoltaic cables. Due to optimized cable de- sign, a constant high volume resistivity can be ensured even after long-term period in not contaminated water. An intentional installation in or under water is not permitted. The cable is suitable for direct burial considering the common VDE installation guide lines. These cross-linked, halogen free and double insulated solar cables are suitable for permanent outdoor use and especially for the interconnection of grounded and ungrounded photovoltaic power systems. They are applicable for the connection of solar panels among themselves and as extension cable between the individual module strings or the DC/AC inverter. 2. Cable design Design according to TÜV specification 2 PfG 1169/08.2007 (PV1-F) Certification code designation PV1-F, certified according to 2 PfG 1169/08.2007 (TÜV certificate number R50202588) 1. Conductor: Fine wire strands of tinned copper according to IEC 60228, Class 5 2. Core insulation: Electron beam cross-linked polyolefin co-polymer Colour: white 3. Outer sheath: Electron beam cross-linked polyolefin co-polymer Outer sheath colour: black or black with red or blue coloured stripe 3. Electrical properties Rated voltage U 0 /U acc. IEC AC 600/1000 V DC 900/1500 V Max. permissible operating voltage DC 1800 V (conductor/conductor, non earthed system) according to 2 PfG 1169/08.2007 Test voltage AC 6,5 kV 4. Mechanical and thermal properties Temperature range fixed installation: -40°C up to +120°C (max. conductor temperature according to EN 60216-2) Temperature range according fixed installation: -40°C up to +90°C ambient temperature (according to TÜV 2 PfG 1169/08.2007) Installation temperature flexible: > -25°C Minimum bending radius occasional flexing: 15 x cable diameter fixed installation: 5 x cable diameter Weathering/UV-resistance according to HD 605/A1 Ozone resistance according to EN 50396

Upload: ajay-chacko

Post on 24-Jan-2016

225 views

Category:

Documents


0 download

DESCRIPTION

datasheet

TRANSCRIPT

Page 1: Data Sheet Olflex Solar XLR WP

U.I. Lapp

GmbH DATA SHEET

ÖLFLEX® SOLAR XLR WP

DB 1023501EN valid from: 22.04.2015

Originator: A. Terpe / PCM

approved: PDC Document: DB1023501EN page 1 of 2

All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34. PD 0019/2.1_11.09EN

1. Application

ÖLFLEX®

SOLAR XLR WP cables are weather-, abrasion- and UV-resistant photovoltaic cables. Due to optimized cable de-

sign, a constant high volume resistivity can be ensured even after long-term period in not contaminated water. An intentional

installation in or under water is not permitted. The cable is suitable for direct burial considering the common VDE installation

guide lines.

These cross-linked, halogen free and double insulated solar cables are suitable for permanent outdoor use and especially for

the interconnection of grounded and ungrounded photovoltaic power systems. They are applicable for the connection of

solar panels among themselves and as extension cable between the individual module strings or the DC/AC inverter.

2. Cable design

Design according to TÜV specification 2 PfG 1169/08.2007 (PV1-F)

Certification code designation PV1-F, certified according to 2 PfG 1169/08.2007

(TÜV certificate number R50202588)

1. Conductor: Fine wire strands of tinned copper according to IEC 60228, Class 5

2. Core insulation: Electron beam cross-linked polyolefin co-polymer

Colour: white

3. Outer sheath: Electron beam cross-linked polyolefin co-polymer

Outer sheath colour: black or black with red or blue coloured stripe

3. Electrical properties

Rated voltage U0/U acc. IEC AC 600/1000 V

DC 900/1500 V

Max. permissible operating voltage DC 1800 V (conductor/conductor, non earthed system)

according to 2 PfG 1169/08.2007

Test voltage AC 6,5 kV

4. Mechanical and thermal properties

Temperature range fixed installation: -40°C up to +120°C

(max. conductor temperature according to EN 60216-2)

Temperature range according fixed installation: -40°C up to +90°C ambient temperature

(according to TÜV 2 PfG 1169/08.2007)

Installation temperature flexible: > -25°C

Minimum bending radius occasional flexing: 15 x cable diameter

fixed installation: 5 x cable diameter

Weathering/UV-resistance according to HD 605/A1

Ozone resistance according to EN 50396

Page 2: Data Sheet Olflex Solar XLR WP

U.I. Lapp

GmbH DATA SHEET

ÖLFLEX® SOLAR XLR WP

DB 1023501EN valid from: 22.04.2015

Originator: A. Terpe / PCM

approved: PDC Document: DB1023501EN page 2 of 2

All deviations from this specification are subject to explicit consent of U.I. Lapp GmbH. All rights reserved acc. to DIN 34. PD 0019/2.1_11.09EN

Halogen free according to EN 50267, IEC 61034

Flame retardant according to IEC 60332-1-2

Acid and alkaline resistance according to EN 60811-2-1 (Oxal-acid and Sodium hydroxide)

Oil resistance according to DIN EN 50290-2-22 resp. VDE 0819-102, TM54

Direct burial according to UL 1277 chapter 19 (Crushing Test),

UL 854 chapter 23 (Impact-Resistance-Test) and

UL 854 chapter 24 (Crushing-Resistance Test)

EU directives This cable is conform to the EU-Directives 2014/35/EU (Low Voltage Directive) and

2011/65/EU (RoHS, Restriction of the use of certain hazardous substances).

5. Underground installation

ÖLFLEX®

SOLAR XLR WP cables are suitable for the installation underground if the cable is laid in a cable trench

according to VDE 0100, part 520 or comparable standards.

Storage or use of the cables in or under not contaminated water (salt or fresh water) is only permitted with the fol-

lowing conditions:

Water temperature: +45°C (maximum)

Water pressure: 0.08 bar; 8kPa (maximum)

6. Versions

Part.No. Colour insulation Colour outer sheath Conductor cross section

[mm²]

Outer diameter approx.

[mm]

1023501 white black 1 x 2.5 5.2

1023502 white black 1 x 4 5.6

1023503 white black 1 x 6 6.2

1023504 white black 1 x 10 7.4

1023505 white black 1 x 16 8.7

1023521 white black + red stripe 1 x 2.5 5.2

1023522 white black + red stripe 1 x 4 5.6

1023523 white black + red stripe 1 x 6 6.2

1023524 white black + red stripe 1 x 10 7.4

1023525 white black + red stripe 1 x 16 8.7

1023526 white black + blue stripe 1 x 2.5 5.2

1023527 white black + blue stripe 1 x 4 5.6

1023528 white black + blue stripe 1 x 6 6.2

1023529 white black + blue stripe 1 x 10 7.4

1023530 white black + blue stripe 1 x 16 8.7