AIR CONDITIONERS XC21 DAVE LENNOX SIGNATURE ® COLLECTION R-410A - Two-Stage Compressor - SilentComfort™ Technology Bulletin No. 210586 November 2017 Supersedes August 2017 SEER up to 21.00 2 to 5 Tons Cooling Capacity - 23,000 to 60,500 Btuh x c 21 - 036 - 230 - 5 Nominal SEER Unit Type C = Air Conditioner Refrigerant Type X = R-410A Nominal Cooling Capacity 024 = 2 tons 036 = 3 tons 048 = 4 tons 060 = 5 tons Minor Revision Number Voltage 230 = 208/230V-1ph-60hz MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS

Upload: dangthuy

Post on 18-Apr-2018

223 views

Category:

Documents


2 download

TRANSCRIPT

A I R C O N D I T I O N E R S

XC21DAVE LENNOX SIGNATURE® COLLECTION

R-410A - Two-Stage Compressor - SilentComfort™ TechnologyBulletin No. 210586

November 2017 Supersedes August 2017

SEER up to 21.002 to 5 Tons

Cooling Capacity - 23,000 to 60,500 Btuh

x c 21 - 036 - 230 - 5

Nominal SEER

Unit Type C = Air Conditioner

Refrigerant Type X = R-410A

Nominal Cooling Capacity 024 = 2 tons 036 = 3 tons 048 = 4 tons 060 = 5 tons

Minor Revision Number

Voltage 230 = 208/230V-1ph-60hz

MODEL NUMBER IDENTIFICATION

P R O D U C T S P E C I F I C AT I O N S

XC21 2-5 TON AIR CONDITIONERS

XC21 - 2 to 5 Ton Air Conditioner / Page 2

WARRANTY

Compressor - ten year limited warranty in residential installations and five years in non-residential installations.

All other covered components - ten years in residential installations and one year in non-residential installations.

Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details.

APPROVALSAHRI Certified to AHRI Standard 210/240-2008Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008.Tested in the Lennox Research Laboratory environmental test room.Rated according to U.S. Department of Energy (DOE) test procedures.Air conditioners and components within bonded for grounding to meet safety standards for servicing required by ETL, NEC, and CEC.Units are ETL certified for the U.S. and Canada.ISO 9001 Registered Manufacturing Quality System.For expanded ratings, see www.LennoxPROs.com.All models are listed in the GreenSpec® Directory, a leading resource of environmentally responsible products.

APPLICATIONSSEER up to 21.00.2 through 5 ton.Single phase power supply.Sound levels as low as 69 dB.Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof.Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches.See Indoor Coils and Air Handlers tab sections for data. Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory insuring proper operation.Installer must set air conditioner, connect refrigerant lines, and make electrical connections to complete job.

B

C

D

E

FG

HK

I

J

FEATURES

CONTENTSAHRI System Matches............................................... 15Dimensions ................................................................ 13Electrical Data............................................................ 11Features....................................................................... 2Field Wiring ................................................................ 12Installation Clearances .............................................. 12Model Number Identification ........................................ 1Optional Accessories ................................................. 11Outdoor Sound Data .................................................. 12Specifications............................................................. 11Sunsource® Home Energy System - Components ...... 7

XC21 - 2 to 5 Ton Air Conditioner / Page 3

REFRIGERATION SYSTEMR-410A RefrigerantNon-chlorine, ozone friendly, R-410A. Unit pre-charged with refrigerant. See Specification table.

Outdoor Coil Fan with SilentComfort™ TechnologySpecially-designed, SilentComfort™ fan guard uses Passive Vortex Suppression to reduce air noise. Constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel. Specially designed fan blades reduce operating sound levels. Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity.Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor is inherently protected. All models have a variable-speed outdoor fan motor for quiet operation. Motor totally enclosed for maximum protection from weather, dust and corrosion. Fan service access accomplished by removal of fan guard.

Copper Tube/Enhanced Fin CoilLennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning.

High Pressure SwitchShuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Automatic reset.

Low Pressure SwitchShuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Automatic reset.

Hi-Capacity Liquid Line DrierFactory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 100% molecular-sieve bead type drier.

A B

C

D

E

F

G

Optional Accessories

Expansion Valve KitsMust be ordered separately and field installed on certain indoor units. See TXV Usage table on page 14.Chatleff style fitting.

FreezestatInstalls on or near the discharge line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it’s setpoint. Opens at 29°F and closes at 58°F.

Refrigerant Line KitsRefrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized, and sealed at factory.Suction line fully insulated.L15 lines are stubbed at both ends.See Specifications table for selection.Not available for -060 model and must be field fabricated.

COMPRESSORCopeland Scroll Ultra Tech™ Two-Stage CompressorCompressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation.Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them.During compression, one scroll remains stationary while the other scroll orbits around it.Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates.As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced.When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle.

H

FEATURES

XC21 - 2 to 5 Ton Air Conditioner / Page 4

COMPRESSOR (continued)Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged.During the compression process, there are several pockets in the scroll that are compressing gas.

Modulation is achieved by venting a portion of the gas in the first suction pocket back to the low side of the compressor thereby reducing the effective displacement of the compressor.A 24-volt DC solenoid valve inside the compressor controls staging. When the 3-way solenoid

is energized it moves the lift ring assembly to block the ports and the compressor operates at full-load or 100% capacity. When the solenoid is de-energized the lift ring assembly moves to unblock the compressor ports and the compressor operates at part-load or approximately 67% of its full-load capacity.The "loading" and "unloading" of the two stage scroll is done “on the fly” without shutting off the single-speed compressor motor between stages.Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature.Compressor is installed in the unit on specially formulated, resilient rubber mounts for better sound dampening and vibration free operation.

Crankcase HeaterCrankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication.

CONTROLSiComfort™ Communicating Control Advanced control communicates information about various operating parameters in the air conditioner to the optional iComfort® Communicating Thermostat to constantly maintain the highest level of comfort, performance and efficiency available.Connections for connecting a conventional heating/cooling thermostat are also provided on the control.Auto Configuration - On start-up the control automatically sends a description of the unit to the optional iComfort® Communicating Thermostat to automatically configure the number of stages and features available.

Seven-Segment DisplaySeven-segment display shows information about outdoor unit type and capacity and also displays alerts for common fault conditions (electrical and mechanical).Control also features:• Compressor anti-short cycle delay. User

selectable with communicating thermostat - 1, 2, 3, 4 or 5 minutes. Default setting is 5 minutes. Compressor must operate in first stage a minimum of 5 seconds before second stage operation is permitted.

• Low voltage protection prevents 2nd stage compressor operation when voltage is not within the specified range.

• High and low pressure switch monitoring with provisions for lockout.

• Five-Strike lockout protection protects compressor.

• Discharge line temperature and sensor monitoring.

• Fan cycling operates outdoor fan for 5 minutes when outdoor ambient air temperature is between 15°F and 35°F and the compressor has been off for 25 to 30 minutes. Reduces the potential for ice buildup on the fan orifice ring. User selectable 5 minutes on or off (default setting).

• Lennox Humiditrol® Whole Home Dehumidification System (EDA) compatible.

• EEPROM storage of all local configurations.

Outdoor Air Temperature Sensor Used with iComfort® Communicating Thermostats.Sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat.Also used for Humiditrol® applications.

I

FEATURES

XC21 - 2 to 5 Ton Air Conditioner / Page 5

CONTROLS (continued)

Optional Accessories

iComfort® S30 Ultra-Smart Thermostat (part of the iComfort® Residential Communicating Control System)The iComfort® S30 Thermostat recognizes and connects to all iComfort® Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for iComfort® Communicating products to simplify system setup.Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders.Dealer Dashboard features online real-time monitoring of installed iComfort® Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen.Easy to read 7 in. high definition color display (measured diagonally).Works with Amazon® Alexa-enabled products.Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 18-gauge standard thermostat wiring.Remote outdoor temperature sensor (furnished with outdoor unit) allows the thermostat to display outdoor temperature. Required in Humiditrol® applications.High Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation.See the iComfort® S30 Thermostat Product Specifications bulletin in the Controls section for more information.

iComfort Wi-Fi® Thermostat (part of the iComfort® Residential Communicating Control System)The iComfort Wi-Fi® Thermostat recognizes and connects to all iComfort® Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for iComfort® Communicating products to simplify system setup.Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders.Dealer Dashboard features online real-time monitoring of installed iComfort® Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen.Easy to read 7-inch color screen (measured diagonally). Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 18-gauge standard thermostat wiring.Remote outdoor temperature sensor (furnished with outdoor unit) allows the thermostat to display outdoor temperature. Required in Humiditrol® applications.See the iComfort Wi-Fi® Thermostat Product Specifications bulletin in the Controls section for more information.

FEATURES

XC21 - 2 to 5 Ton Air Conditioner / Page 6

CONTROLS (continued)

Optional Accessories

ComfortSense® 7500 Touchscreen ThermostatElectronic 7-day, universal, multi-stage, programmable, touchscreen thermostat.4 Heat/2 Cool.Auto-changeover.Controls dehumidification during cooling mode.Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol® control, and equipment maintenance reminders.Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen.See the ComfortSense® 7500 Product Specifications bulletin in the Controls section for more information.

Remote Outdoor Temperature Sensor for ComfortSense® 7500 ThermostatAllows the thermostat to display outdoor temperature. Required in Humiditrol® applications.

ThermostatThermostat is not furnished with unit.See Thermostat bulletins in Controls Section and Lennox Price Book for selection.

Blower Relay Kit (For Use With EL195E and ML180E Gas Furnaces)Allows furnace blower speed changes when matched with two-stage air conditioners.

Compressor Hard Start KitSingle-phase units are equipped with a PSC compressor motor.This type of motor normally does not need a potential relay and start capacitor.In conditions such as low voltage, kit may be required to increase the compressor starting torque.

Indoor Blower Off Delay RelayDelays the indoor blower-off time during the cooling cycle. Required if outdoor unit is used with a conventional heating-cooling thermostat and air handler (not iComfort® Communicating). See furnace or air handler specifications to determine if relay is needed.

Indoor Blower Speed Relay KitRelay kit provides the option of changing blower speeds on standard permanent split capacitor (PSC) multi-tap blower motors during cooling operation.Provides optimum humidity control conditions by automatically reducing indoor blower speed during continuous fan operation or low stage compressor operation to reduce humidity levels.

FEATURES

Low Ambient KitAir conditioner will operate satisfactorily down to 45°F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30°F.A Freezestat should be installed on compressors equipped with a Low Ambient Kit.A Compressor Low Ambient Cut-Off Switch should be added to terminate compressor operation below recommended operation conditions.

CABINETHeavy-gauge steel constructionPre-painted cabinet finish.Compressor and control box located in a separate compartment, insulated with thick fiberglass insulation. Compartment provides protection from the weather and keeps sound transmission at a minimum.Control box is conveniently located with all controls factory wired.Large removable panel provides service access.Drainage holes are provided in base section for moisture removal.High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture.

PermaGuard™ Unit BaseDurable zinc-coated base section resists rust and corrosion.

SmartHinge™ Louvered Coil ProtectionSteel louvered panels provides complete coil protection.Panels are hinged to allow easy cleaning and servicing of coils.Panels may be completely removed.Interlocking tabs and slots assure tight fit on cabinet.

Refrigerant Line Connections, Electrical Inlets and Service ValvesSuction and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing.Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system.Suction and liquid line service valves and gauge ports are located inside the cabinet.Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing.

J

K

XC21 - 2 to 5 Ton Air Conditioner / Page 7

SUNSOURCE® HOME ENERGY SYSTEM - COMPONENTS

SYSTEM OVERVIEWAll Dave Lennox Signature® Collection air conditioners and heat pumps are equipped at the factory for upgrading to the SunSource® Home Energy System.Units can be upgraded at the time of installation or in the future.Solar energy is first used to meet cooling/heating demands. When the cooling/heating system is not operating, the system powers lighting, appliances and other electronic devices in the home. And in some locations, any surplus power is sent back to the utility company for a possible credit (check with your local utility company for availability).The SunSource system consists of the following components:• Lennox Solar Sub-Panel field installed in a Dave

Lennox Signature® Collection air conditioner or heat pump unit.

• SolarWorld Pre-Engineered Kits consisting of:• SolarWorld Solar Modules (1 to 16 may be used

to vary the amount of electricity generated).• Enphase Microinverter that converts Direct

Current to Alternating Current.• Enphase Envoy Communications Gateway for

solar power performance monitoring.• Roof Mounting Components.Wiring from the roof mounted solar modules is routed to the outdoor unit. From there power travels to the home electrical service panel using the existing outdoor unit power wiring.NOTE - Refer to separate Product Specifications Bulletin for the SunSource® Home Energy System for more detailed information. See section Solar - Kits/Accessories.Also refer to SunSource® Home Energy System Applications and Design Guidelines Manual (Corp. 1312-L2) for complete information on designing, sizing and installing a complete system.

APPROVALSThe SunSource® Home Energy System meets the requirements for federal tax credit eligibilty listed under the U.S. Emergency Economic Stabilization Act of 2008, covering 30% of the cost of the solar modules, including installation.

LENNOX® SOLAR SUB-PANELThe Lennox® Solar Sub-Panel replaces the factory piping panel on the outdoor unit and provides circuit breaker protection and power entry for both HVAC (line) and solar power wiring.Sub-Panel is equipped with separate circuit breakers for both HVAC (line) voltage and solar power.Equipped with pigtail connections for easy field wiring.Sub-Panel is an ETL listed accessory.Split design (upper/lower panel) allows installation on different size outdoor units. Sub-Panel is furnished with three separate lower panels. See Outdoor Unit Usage table for correct lower panel size.NOTE - Sub-Panel is not backwards compatible with older non Solar-Ready Dave Lennox Signature® Collection outdoor units.Disconnects for HVAC (line) and solar power wiring are not furnished and must be field provided.

Solar Modules

Future Modules

Air Conditioneror Heat Pump

StandardOutlet

CommunicationGateway

PerformanceMonitoring

Website

BroadbandInternet

Connection

ElectricalPanel

Unit

XC21 - 2 to 5 Ton Air Conditioner / Page 8

SUNSOURCE® HOME ENERGY SYSTEM - COMPONENTS

SOLAR MODULECaptures solar energy to convert into AC power through the Enphase Microinverter.

Laminated solar module structure consists of the solar glass, two ethylene vinyl acetate (EVA) sheets, the solar cell matrix and a back sheet.Thick low-iron safety glass withstands extreme weather conditions and heavy snow loads.Solar modules are ETL/Intertek listed for the US and Canada to UL Standard 1703 and meet National and Canadian Electrical Code requirements.

Solar Module FrameAvailable in black or clear anodized silver frame with cast aluminum corner keys.Low profile with extended flange.Compatible with “top-down” and “bottom-up” mounting methods.Eight grounding locations (Four corners of the frame and four locations along the length of the module in the extended flange).Extended cable lengths for easier installation.

ENPHASE MICROINVERTER

Converts Direct Current (DC), captured by a solar module, to Alternating Current (AC) power. Each solar module is paired with one Enphase Microinverter. Installed beneath each solar module on the roof.Enphase Microinverters operate independently from each other allowing solar modules that are not shaded or dirty to operate with optimum performance.Supports low-light and low-voltage operation.

SYSTEM MONITORINGEnphase Envoy Communications Gateway (Communications Booster Furnished)The Enphase Envoy Communications Gateway monitors microinverter (on solar modules) performance and can be connected to a broadband internet connection to send data to the Enphase Enlighten™ web site for online monitoring by the homeowner. The Enphase Envoy Communications Gateway is not required, but must be used if system performance monitoring is desired.Limited system monitoring is also available locally with the Enphase Envoy Communications Gateway and a personal computer if no internet connection is available.Various Event Messages are also available when monitoring the system via a personal computer locally.Contents - (1) Enphase Envoy Communications Gateway, (1) Communications Booster, (1) 6 ft. power cord, (1) 10 ft. Ethernet cable, communications booster.CSA (US/C) listed.The Enphase Envoy Communications Gateway includes a Communications Booster which may or may not be needed depending upon how far the Envoy is away from the solar modules.

Communications BoosterEthernet bridge signal booster for the Enphase Envoy Communications Gateway. Booster is only needed if the communications gateway is installed and signal is not strong enough in the installed location. Allows the unit to be plugged into an outlet closer to the distribution panel, yet still plug into the broadband router.

Enphase Enlighten™ Performance Monitoring Website

Powered by the Enphase Envoy Communications Gateway, the Enphase Enlighten™ Performance Monitoring website allows the homeowner to keep track of home energy usage and see environmental benefits in real time. Also aids in troubleshooting any solar-related issues.

See demos, view reference installations and other additional information at: http://enlighten.enphaseenergy.com/

XC21 - 2 to 5 Ton Air Conditioner / Page 9

SUNSOURCE® HOME ENERGY SYSTEM - COMPONENTS

B

C

D

E

F

G

H

I

ROOF MOUNTING COMPONENTS

Rails - Provides a mounting surface for Solar Modules in portrait orientation using associated hardware. Serrations on sides of rails provide a secure and stable mating surface for hardware (L-Brackets, Rail Splice Ground Jumper, Ground Lug). Available in 122 in. (3099 mm) and 162 in. (4115 mm) lengths.

Rail Splice Bar Connector - For connecting two lengths of rail together. No fasteners required. Pin on center of splice leaves a gap between rails to allow for thermal expansion.

Top Clamp Assembly (Silver or Black) - M8 T40 bolt with channel nut, bolt positioning retainer and serrated module clamping washer. Inserts into rail slot to secure modules and set spacing in-between each one.

End Clamp Aluminum Spacer (Silver or Black) - Used with Top Clamp Assembly for securing the end of module mounting row.

Composition Roof Mount/Flashing (Mil Aluminum or Bronze) - Provides roof mounting surface for mounting system. Size - 12 x 12 in. (305 x 305 mm). Base block, hanger bolt and hardware furnished. Adds 1-1/4 in. (32 mm) height below the L-Bracket.

L-Bracket - Clear anodized aluminum with serrated mating surface. Fastens rail to Roof Mount/Flashing. Has two 1 in. (25 mm) slots that provide adjustment from 2-1/2 to 3-1/2 in. (64 to 89 mm).

Wire Clip (not shown) - Provides wire management for solar array wiring. Fastens to edge of rail. For 10 AWG.

Ground Lug (not shown) - Tin plated, WEEB 8.0, lay-in type. Mounts to corner of solar module.

Rail-Equipment Ground WEEB 8.0 Lug - T-bolt slides into rail for secure connection.

Rail Splice Ground Jumper - WEEB 8.0, pre-assembled with T-bolts. Electrically bonds rails together. Required at each rail splice.

A

B

C

D

E

F

G

H

I

Rooftop Junction Box (not shown) - Soladeck JBox with flashing. Used to transition from the AC-Interconnection cable to wiring/conduit to the outdoor unit. ETL-listed weather-tight enclosure.

Passthru Kit (not shown) - Used with Rooftop Junction Box. One-branch AC passthru kits. Contains all necessary wiring hardware.

ENPHASE ENGAGE CABLE COMPONENTS

Enphase Engage Cable - The Engage Cable (shown with connector) is a 12 AWG cable with pre-installed connectors (portrait aligned) that plug into the

Microinverter. Four wire cable (240V single-phase).

Enphase Engage Cable Terminator - Each Engage Cable is terminated at a junction or combiner box. The opposite end of the cable must be terminated with an Engage Cable Terminator cap.

Enphase Engage Disconnect Tool - Specialized tool that disconnects the Engage Cable from a Microinverter or watertight sealing cap.

Enphase Engage Water-tight Sealing Cap - Use when open connections on the Engage Cable are not mated to a Microinverter.

ENPHASE MICROINVERTER MOUNTING L-Bracket and associated hardware to mount microinverter to rail.

XC21 - 2 to 5 Ton Air Conditioner / Page 10

SUNSOURCE® - PRE-ENGINEERED KITS

ORDERINGSunSource® Pre-Engineered Kits are available for composition shingle roofs, standing seam roofs, trapezoid metal roofs, flat tile roofs and S tile roofs. See the Sunsource Home Energy System Product Specifications bulletin for complete Pre-Engineered Kits ordering instructions and the Ordering Process Flowchart/Worksheet.The Installation Package contains the appropriate number of required Rails, Splices, Brackets, Clamps, Clips and assorted hardware (nuts/bolts/washers) for the installation.NOTEThe Lennox® Solar Sub-Panel for the outdoor unit must be ordered separately. See below for ordering information.

Lennox® Solar Sub-Panel

Order one per outdoor unit. Replaces the outdoor unit piping panel and provides the connection between the solar modules and outdoor unit.

62E02

LENNOX® SOLAR SUBPANEL - OUTDOOR UNIT USAGE

Outdoor Unit Model No.Lower Subpanel Height - in. (mm)

27 (686)XC21 (All Sizes) X

XC21 - 2 to 5 Ton Air Conditioner / Page 11

SPECIFICATIONSGeneral Data

Model No. XC21-024 XC21-036 XC21-048 XC21-060Nominal Tonnage 2 3 4 5

Connections (sweat)

Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8Suction line (o.d.) - in. 7/8 7/8 7/8 1-1/8

Refrigerant 1 R-410A charge furnished 11 lbs. 12 oz. 12 lbs. 5 oz. 13 lbs. 8 oz. 12 lbs. 8 oz.Outdoor Coil

Net face area - sq. ft. Outer coil 27.21 27.21 27.21 27.21Inner coil 26.36 26.36 26.36 26.36

Tube diameter - in. 5/16 5/16 5/16 5/16No. of rows 2 2 2 2

Fins per inch 22 22 22 22Outdoor Fan

Diameter - in. 26 26 26 26No. of blades 5 5 5 5

Motor hp 1/3 1/3 1/3 1/3Cfm - 1st stage 2500 3350 3825 3825

2nd stage 2900 3845 4230 4230Rpm - 1st stage 425 525 600 600

2nd stage 500 600 675 675Watts - 1st stage 50 90 135 135

2nd stage 75 125 185 185Shipping Data - lbs. - 1 pkg. 314 331 337 338

ELECTRICAL DATALine voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph2 Maximum overcurrent protection (amps) 25 35 45 603 Minimum circuit ampacity 20 21.1 28.5 35.8Compressor Rated load amps 11.7 15.3 21.2 27.1

Locked rotor amps 58.3 83 104 152.9Power factor 0.98 0.98 0.98 0.98

Outdoor Fan Motor - Full load amps 2.0 2.0 2.0 2.0

CONTROLSiComfort® S30 Thermostat 12U67 • • • •iComfort Wi-Fi® Thermostat 10F81 • • • •ComfortSense® 7500 Thermostat 13H14 • • • •Outdoor Temperature Sensor - for ComfortSense® 7500

X2658 • • • •

4 Discharge Air Temp. Sensor 88K38 • • • •OPTIONAL ACCESSORIES - ORDER SEPARATELYBlower Relay Kit (for EL195E and ML195E gas furnaces)

85W66 • • • •

Compressor Hard Start Kit - Required in applications with less than 230V

10J42 • •12J90 • •

Freezestat 3/8 in. tubing 93G35 • • • •5/8 in. tubing 50A93 • • • •

Indoor Blower Speed Relay Kit 40K58 • • • •5 Low Ambient Kit (Fan Cycling) 68M04 • • • •Refrigerant Line Sets

L15-65-30 L15-65-40 L15-65-50

• • • •

Field Fabricate • • • •Indoor Blower Off Delay Relay 58M81 • • • • NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines.2 HACR type breaker or fuse.3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.4 Used with the iComfort® Communicating Thermostats for optional service diagnostics.5 Freezestat is recommended with Low Ambient Kit.

XC21 - 2 to 5 Ton Air Conditioner / Page 12

OUTDOOR SOUND DATA

1 Unit Model No.

Octave Band Linear Sound Power Levels dB, re 10-12 Watts 1Sound Rating

Number (dB)

Center Frequency - HZ

125 250 500 1000 2000 4000 8000XC21-024 54.5 61 64 62 60 56 49 69XC21-036 60 65 66.5 64.5 61.5 56.5 50 71XC21-048 59.5 66.5 68 67 63 58 52 73XC21-060 60 65.5 70 68.5 64 57 50.5 73NOTE - the octave sound power data does not include tonal correction.1 Tested according to AHRI Standard 270-2008 test conditions.

SeeNotes

SeeNotes

SeeNotes

SeeNotes

Service

NOTES - One of these three sides must be 36 in. (914 mm).One of the two remaining sides may be 12 in. (305 mm).The remaining side may be 6 in. (152 mm).

Service Clearance − 30 in. (762 mm)

48 in. (1219 mm) clearance required on top of unit24 in. (610 mm) required between two units

B

DISCONNECTSWITCH

(By Others)

LENNOXAIR

CONDITIONER

LENNOXHEATING UNIT

ORAIR HANDLER

UNIT

DISCONNECTSWITCH

(By Others)THERMOSTAT

(Optional)

C

DA

A - Two Wire Power (not furnished)B - Two Power (not furnished) See Electrical DataC - Four Wire Low Voltage (not furnished) 18 ga. minimumD - Six Wire Low Voltage (not furnished) 18 ga. minimum -

With Conventional Thermostat Four Wire Low Voltage RSBus (not furnished) 18 ga. minimum - With iComfort® Communicating Thermostat

All wiring must conform to NEC or CEC and local electrical codes.

INSTALLATION CLEARANCES - INCHES (MM)

FIELD WIRING

XC21 - 2 to 5 Ton Air Conditioner / Page 13

39-1/2 (1003) 35-1/2 (902)

47(1194)

18-1/2(470)

8 (203)

1 (25)

4-1/2(114)

LIQUID LINEINLET

SUCTION LINEINLET

ELECTRICALINLETS

TOP VIEW

WEIV SSECCAWEIV EDIS

DISCHARGE AIR

UNIT SUPPORTFEET

TOP VIEW BASE SECTION(Large Base)

16-7/8(429)

4-5/8(117)

26-7/8(683)

8-3/4(222)

30-3/4(781)

3-3/4(95)

3-1/8(79)

DIMENSIONS - INCHES (MM)

XC21 - 2 to 5 Ton Air Conditioner / Page 14

TXV USAGEUse this table for C33, C35, CH23, CH33, CH35 and CR33 Field Installed TXV Match-Ups.Outdoor Unit Model No.

Order No.

XC21-024 12J18XC21-036 12J19XC21-048 12J20XC21-060 12J20CX34 and CX35 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed.If a change out is required it will be listed in the “TXV SUBSTITUTIONS” table. The correct TXV must be ordered and field installed.C33, C35, CH33 and CH35 coils - Factory installed orifice must be replaced with the expansion valve listed.CR33 and CH23 coils - Use the expansion valve listed.

MOST POPULAR MATCHESOutdoor Unit Model No.

Indoor Unit Model No

XC21-024 CX34-31 + SL280UH090V36BXC21-036 CX34-49 + SL280UH090V60CXC21-048 CX34-49 + SL280UH090V60CXC21-060 CX34-62D + SL280UH135V60D

AHRI STANDARD 210/240

Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation.Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated.

*TXV SUBSTITUTIONSUse this table to determine if the factory installed TXV in the indoor unit needs to be replaced.Outdoor Unit Model No.

Indoor Coil or Air Handler

Factory TXV

Replacement TXV

XC21-024 CX34-42 12J20 12J18

XC21-024 CX35-48 12J20 12J18

XC21-048 CBX32MV-036 12J19 12J20

XC21-048 CBX40UHV-036 12J19 12J20* CX34, CX35 coils and all air handlers - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used.

XC21 - 2 to 5 Ton Air Conditioner / Page 15

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-024-230 TXV 24000 19 14 C35-24A EL180UH045E36A 8248660XC21-024-230 TXV 24000 20 14 C35-24A SL280UH070V36A 8248661XC21-024-230 TXV 24000 20 14 C35-24A SL280UH070XV36A 8248662XC21-024-230 TXV 24000 17 13 C35-24A 8248663XC21-024-230 TXV 24000 19 14 C35-24B EL296UH045XV36B 8248664XC21-024-230 TXV 24000 20 14 C35-24B EL296UH070XV36B 8248665XC21-024-230 TXV 24000 19 14.5 C35-24B SL280UH090V48B 8248666XC21-024-230 TXV 24000 20 14 C35-24B SLP98UH070XV36B 8249634XC21-024-230 TXV 24000 17 13 C35-24B 8248667XC21-024-230 TXV 24000 20 14 C35-30/36C EL296UH090XV36C 8248678XC21-024-230 TXV 24000 20 14 C35-30/36C SLP98UH090XV36C 8248679XC21-024-230 TXV 24000 17 13 C35-30/36C 8248680XC21-024-230 TXV 24000 19 14 C35-30A EL180UH045E36A 8248668XC21-024-230 TXV 24000 20 14 C35-30A EL296UH045XV36B 8248681XC21-024-230 TXV 24000 20 14 C35-30A SL280UH070V36A 8248669XC21-024-230 TXV 24000 20 14 C35-30A SL280UH070XV36A 8248670XC21-024-230 TXV 24000 17 13 C35-30A 8248671XC21-024-230 TXV 24000 19 14 C35-30B CBWMV-36B-070 8248672XC21-024-230 TXV 24000 19 14 C35-30B EL296UH045XV36B 8248674XC21-024-230 TXV 24000 19 14 C35-30B EL296UH070XV36B 8248675XC21-024-230 TXV 24000 19 14 C35-30B SL280UH090V48B 8248676XC21-024-230 TXV 24000 20 14 C35-30B SL280UH090XV36B 10040429XC21-024-230 TXV 24000 19 14 C35-30B SL280UH090XV48B 8248683XC21-024-230 TXV 24000 20 14 C35-30B SLP98UH070XV36B 8248684XC21-024-230 TXV 24000 17 13 C35-30B 8248677XC21-024-230 TXV 24000 19 14 C35-36A EL180UH045E36A 8248686XC21-024-230 TXV 24000 20 14 C35-36A SL280UH070V36A 8249635XC21-024-230 TXV 24000 20 14 C35-36A SL280UH070XV36A 8249636XC21-024-230 TXV 24000 17 13 C35-36A 8248689XC21-024-230 TXV 24000 20 14 C35-36B EL296UH045XV36B 8248690XC21-024-230 TXV 24000 20 14 C35-36B EL296UH070XV36B 8248692XC21-024-230 TXV 24000 21 14 C35-36B SL280UH090V36B 8249637XC21-024-230 TXV 24000 19 14 C35-36B SL280UH090V48B 8248694XC21-024-230 TXV 24000 20 14 C35-36B SLP98UH070XV36B 8248696XC21-024-230 TXV 24000 17 13 C35-36B 8248698XC21-024-230 TXV 24000 20 14 C35-48B EL296UH045XV36B 8248700XC21-024-230 TXV 24000 20 14 C35-48B EL296UH070XV36B 8248701XC21-024-230 TXV 24000 20 14 C35-48B SL280UH090V36B 8249638XC21-024-230 TXV 24000 19 14 C35-48B SL280UH090V48B 8248702XC21-024-230 TXV 24000 20 14 C35-48B SLP98UH070XV36B 8248703XC21-024-230 TXV 24000 17 13 C35-48B 8248704XC21-024-230 TXV 24000 19 15 CBA27UHE-024 10259509XC21-024-230 TXV 24000 20.5 13.5 CBA27UHE-030 10259510XC21-024-230 TXV 25800 19 15 CBX27UH-024 5992461XC21-024-230 TXV 24600 19 13.5 CBX27UH-030 5992462XC21-024-230 TXV 25200 17 13.5 CBX32M-018/024 5992453XC21-024-230 TXV 25400 17 13.5 CBX32M-030 5992454XC21-024-230 TXV 25200 19 14 CBX32M-036 5992455NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 16

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-024-230 TXV 25600 19 14 CBX32MV-018/024 5992456XC21-024-230 TXV 26200 21 15 CBX32MV-024/030 5992457XC21-024-230 TXV 25800 20.5 15 CBX32MV-036 5992458XC21-024-230 TXV 25800 20 15 CBX40UHV-024 5992459XC21-024-230 TXV 25600 21 15 CBX40UHV-030 5992604XC21-024-230 TXV 25600 19 14 CBX40UHV-036 5992460XC21-024-230 TXV 23600 18 13.5 CH23-21 EL296UH045XV36B 5992517XC21-024-230 TXV 23600 18 13.5 CH23-21 EL296UH070XV36B 5992537XC21-024-230 TXV 23400 18 13.5 CH23-21 EL296UH090XV36C 5992554XC21-024-230 TXV 23600 18 13.5 CH23-21 SL280UH070V36A 5992422XC21-024-230 TXV 23600 18 13.5 CH23-21 SL280UH070XV36A 5992586XC21-024-230 TXV 23400 18 13.5 CH23-21 SL280UH090V36B 5992603XC21-024-230 TXV 23600 17 13 CH23-21 SL280UH090V48B 5992497XC21-024-230 TXV 23600 18 13.5 CH23-21 SLP98UH070XV36B 5992423XC21-024-230 TXV 23000 15.5 12.2 CH23-21 5992373XC21-024-230 TXV 23800 18 14 CH23-31 EL296UH045XV36B 5992518XC21-024-230 TXV 23800 18 14 CH23-31 EL296UH070XV36B 5992538XC21-024-230 TXV 23800 18 14 CH23-31 EL296UH090XV36C 5992555XC21-024-230 TXV 24000 19 13.5 CH23-31 SL280UH070V36A 5992424XC21-024-230 TXV 26000 20 14 CH23-31 SL280UH070XV36A 5992587XC21-024-230 TXV 26200 20 15 CH23-31 SL280UH090V36B 5992442XC21-024-230 TXV 23600 18.2 13 CH23-31 SL280UH090V48B 5992498XC21-024-230 TXV 24000 19 14 CH23-31 SLP98UH070XV36B 5992425XC21-024-230 TXV 24000 19 14 CH23-31 SLP98UH090XV36C 5992426XC21-024-230 TXV 23200 15.7 12.2 CH23-31 5992374XC21-024-230 TXV 25200 19 14 CH23-41 EL296UH045XV36B 5992519XC21-024-230 TXV 25200 18 14 CH23-41 EL296UH070XV36B 5992539XC21-024-230 TXV 25200 19 14 CH23-41 EL296UH090XV36C 5992556XC21-024-230 TXV 25400 20 14 CH23-41 SL280UH070V36A 5992427XC21-024-230 TXV 25400 20 14 CH23-41 SL280UH070XV36A 5992588XC21-024-230 TXV 25800 20 14 CH23-41 SL280UH090V36B 5992428XC21-024-230 TXV 25000 19 14 CH23-41 SL280UH090V48B 5992499XC21-024-230 TXV 25400 19 14 CH23-41 SLP98UH070XV36B 5992429XC21-024-230 TXV 25400 20 14 CH23-41 SLP98UH090XV36C 5992430XC21-024-230 TXV 24600 16 13 CH23-41 5992375XC21-024-230 TXV 25400 19 14 CH23-51 EL296UH045XV36B 5992520XC21-024-230 TXV 25400 20 14 CH23-51 EL296UH070XV36B 5992540XC21-024-230 TXV 25400 20 15 CH23-51 EL296UH090XV36C 5992557XC21-024-230 TXV 25600 20 14.5 CH23-51 SL280UH070V36A 5992431XC21-024-230 TXV 25600 20 14.5 CH23-51 SL280UH070XV36A 5992589XC21-024-230 TXV 25800 20 15 CH23-51 SL280UH090V36B 5992432XC21-024-230 TXV 25200 19 14 CH23-51 SL280UH090V48B 5992500XC21-024-230 TXV 25600 20 14 CH23-51 SLP98UH070XV36B 5992433XC21-024-230 TXV 25600 20 14 CH23-51 SLP98UH090XV36C 5992434XC21-024-230 TXV 24800 17 13 CH23-51 5992376XC21-024-230 TXV 25000 19 14 CH33-19 SL280UH070V36A 5992435XC21-024-230 TXV 25000 19 14 CH33-19 SL280UH070XV36A 5992590XC21-024-230 TXV 24200 16 12.5 CH33-19 5992377NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 17

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-024-230 TXV 24800 19 14 CH33-24/30 SL280UH070V36A 5992436XC21-024-230 TXV 24800 19 14 CH33-24/30 SL280UH070XV36A 5992591XC21-024-230 TXV 24200 16 12.5 CH33-24/30 5992346XC21-024-230 TXV 25200 19 14 CH33-25 EL296UH045XV36B 5992507XC21-024-230 TXV 25200 20 14 CH33-25 EL296UH070XV36B 5992541XC21-024-230 TXV 25600 20 14 CH33-25 SL280UH070V36A 5992437XC21-024-230 TXV 25600 20 14 CH33-25 SL280UH070XV36A 5992592XC21-024-230 TXV 25600 20 14 CH33-25 SL280UH090V36B 5992438XC21-024-230 TXV 25000 19.2 14.2 CH33-25 SL280UH090V48B 5992501XC21-024-230 TXV 25400 20 14 CH33-25 SLP98UH070XV36B 5992439XC21-024-230 TXV 25000 17 13 CH33-25A 5992347XC21-024-230 TXV 24800 17 13 CH33-25B 5992348XC21-024-230 TXV 26000 20 15 CH33-31 EL296UH045XV36B 5992521XC21-024-230 TXV 26000 20 15 CH33-31 EL296UH070XV36B 5992542XC21-024-230 TXV 26000 20 14.5 CH33-31 SL280UH070V36A 5992440XC21-024-230 TXV 26000 20 14.5 CH33-31 SL280UH070XV36A 5992593XC21-024-230 TXV 26400 20 15 CH33-31 SL280UH090V36B 5992441XC21-024-230 TXV 25800 19 14.5 CH33-31 SL280UH090V48B 5992502XC21-024-230 TXV 25200 20 14 CH33-31 SLP98UH070XV36B 5992443XC21-024-230 TXV 25400 17 13 CH33-31A 5992349XC21-024-230 TXV 25400 17 13 CH33-31B 5992350XC21-024-230 TXV 25200 19 14 CH33-36 EL296UH045XV36B 5992522XC21-024-230 TXV 25200 19 14 CH33-36 EL296UH070XV36B 5992543XC21-024-230 TXV 25400 20 15 CH33-36 EL296UH090XV36C 5992552XC21-024-230 TXV 25600 19 14 CH33-36 SL280UH070V36A 5992444XC21-024-230 TXV 25200 19 14 CH33-36 SL280UH070XV36A 5992594XC21-024-230 TXV 25400 20 14 CH33-36 SL280UH090V36B 5992445XC21-024-230 TXV 25600 20 15 CH33-36 SLP98UH070XV36B 5992446XC21-024-230 TXV 26200 20 15 CH33-36 SLP98UH090XV36C 5992447XC21-024-230 TXV 24600 17 13 CH33-36A 5992351XC21-024-230 TXV 25000 19 14 CH33-36B SL280UH090V48B 5992503XC21-024-230 TXV 24600 17 13 CH33-36B 5992352XC21-024-230 TXV 24800 17 13 CH33-36C 5992353XC21-024-230 TXV 25800 20 15 CH33-42 EL296UH045XV36B 5992523XC21-024-230 TXV 25800 20 15 CH33-42 EL296UH070XV36B 5992544XC21-024-230 TXV 26000 20 15 CH33-42 SL280UH090V36B 5992448XC21-024-230 TXV 25600 19 14 CH33-42 SL280UH090V48B 5992504XC21-024-230 TXV 26800 20 15.5 CH33-42 SLP98UH070XV36B 5992449XC21-024-230 TXV 25200 17 13 CH33-42 5992354XC21-024-230 TXV 26400 20 15 CH33-43 EL296UH045XV36B 5992524XC21-024-230 TXV 26400 20 15 CH33-43 EL296UH070XV36B 5992545XC21-024-230 TXV 26200 21 15.5 CH33-43 EL296UH090XV36C 5992553XC21-024-230 TXV 26600 20 15 CH33-43 SL280UH090V36B 5992450XC21-024-230 TXV 26200 20 14.5 CH33-43 SL280UH090V48B 5992505XC21-024-230 TXV 26400 21 15.5 CH33-43 SLP98UH070XV36B 5992451XC21-024-230 TXV 24800 17 13 CH33-43 SLP98UH090XV36C 5992452XC21-024-230 TXV 25800 17 13.5 CH33-43B 5992355XC21-024-230 TXV 25600 17 13.5 CH33-43C 5992356NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 18

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-024-230 TXV 24000 19 13 CH35-18A EL180UH045E36A 7164909XC21-024-230 TXV 24000 20 14 CH35-18A SL280UH070V36A 7165559XC21-024-230 TXV 24000 20 14 CH35-18A SL280UH070XV36A 7165560XC21-024-230 TXV 24000 16 12.5 CH35-18A 7164908XC21-024-230 TXV 24000 19 14 CH35-24A EL180UH045E36A 7164911XC21-024-230 TXV 24000 20 14 CH35-24A SL280UH070V36A 7165561XC21-024-230 TXV 24000 20 14 CH35-24A SL280UH070XV36A 7165562XC21-024-230 TXV 24000 17 13 CH35-24A 7164910XC21-024-230 TXV 24000 19 13 CH35-24B EL195UH045XE36B 7164913XC21-024-230 TXV 24000 19 14 CH35-24B EL195UH070XE36B 7164914XC21-024-230 TXV 24000 19 13 CH35-24B EL296UH045XE36B 7164915XC21-024-230 TXV 24000 19 14 CH35-24B EL296UH045XV36B 7164917XC21-024-230 TXV 24000 19 14 CH35-24B EL296UH070XE36B 7164916XC21-024-230 TXV 24000 20 14 CH35-24B EL296UH070XV36B 7164918XC21-024-230 TXV 24000 20 15 CH35-24B SL280UH090V36B 7165563XC21-024-230 TXV 24000 19 14 CH35-24B SL280UH090V48B 7164919XC21-024-230 TXV 24000 20 14 CH35-24B SLP98UH070XV36B 7165564XC21-024-230 TXV 24000 17 13 CH35-24B 7164912XC21-024-230 TXV 24000 19 14 CH35-30A EL180UH045E36A 7164921XC21-024-230 TXV 24000 20 14 CH35-30A SL280UH070V36A 7165565XC21-024-230 TXV 24000 20 14 CH35-30A SL280UH070XV36A 7165566XC21-024-230 TXV 24000 17 13 CH35-30A 7164920XC21-024-230 TXV 24000 19 14 CH35-30B EL195UH045XE36B 7164923XC21-024-230 TXV 24000 19 14 CH35-30B EL195UH070XE36B 7164924XC21-024-230 TXV 24000 19 14 CH35-30B EL296UH045XE36B 7164925XC21-024-230 TXV 24000 20 15 CH35-30B EL296UH045XV36B 7164927XC21-024-230 TXV 24000 19 14 CH35-30B EL296UH070XE36B 7164926XC21-024-230 TXV 24000 20 15 CH35-30B EL296UH070XV36B 7164928XC21-024-230 TXV 24000 20 15 CH35-30B SL280UH090V36B 7165567XC21-024-230 TXV 24000 19 14 CH35-30B SL280UH090V48B 7164929XC21-024-230 TXV 24000 20 15 CH35-30B SLP98UH070XV36B 7165568XC21-024-230 TXV 24000 17 13 CH35-30B 7164922XC21-024-230 TXV 24000 19 14 CH35-36A EL180UH045E36A 9857587XC21-024-230 TXV 24000 20 14 CH35-36A SL280UH070V36A 7165569XC21-024-230 TXV 24000 20 14 CH35-36A SL280UH070XV36A 7165570XC21-024-230 TXV 24000 17 13 CH35-36A 7164930XC21-024-230 TXV 24000 19 13 CH35-36B EL195UH045XE36B 7164933XC21-024-230 TXV 24000 19 13 CH35-36B EL195UH070XE36B 7164934XC21-024-230 TXV 24000 19 13 CH35-36B EL296UH045XE36B 7164935XC21-024-230 TXV 24000 19 14 CH35-36B EL296UH045XV36B 7164937XC21-024-230 TXV 24000 19 13 CH35-36B EL296UH070XE36B 7164936XC21-024-230 TXV 24000 20 14 CH35-36B EL296UH070XV36B 7164938XC21-024-230 TXV 24000 20 14 CH35-36B SL280UH090V36B 7165571XC21-024-230 TXV 24000 19 14 CH35-36B SL280UH090V48B 7164939XC21-024-230 TXV 24000 20 14 CH35-36B SLP98UH070XV36B 7165572XC21-024-230 TXV 24000 17 13 CH35-36B 7164932XC21-024-230 TXV 24000 20 15 CH35-36C EL296UH090XV36C 7164941XC21-024-230 TXV 24000 20 15 CH35-36C SLP98UH090XV36C 7165573NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 19

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-024-230 TXV 24000 17 13 CH35-36C 7164940XC21-024-230 TXV 24000 19 14 CH35-42B EL195UH045XE36B 7164943XC21-024-230 TXV 24000 20 14 CH35-42B EL195UH070XE36B 7164944XC21-024-230 TXV 24000 19 14 CH35-42B EL296UH045XE36B 7164945XC21-024-230 TXV 24000 20 15 CH35-42B EL296UH045XV36B 7164947XC21-024-230 TXV 24000 20 14 CH35-42B EL296UH070XE36B 7164946XC21-024-230 TXV 24000 20 15 CH35-42B EL296UH070XV36B 7164948XC21-024-230 TXV 24000 20 15 CH35-42B SL280UH090V36B 7165574XC21-024-230 TXV 24000 20 15 CH35-42B SL280UH090V48B 7164949XC21-024-230 TXV 24000 21 15 CH35-42B SLP98UH070XV36B 7165575XC21-024-230 TXV 24000 17 13 CH35-42B 7164942XC21-024-230 TXV 24000 21 15 CH35-42C EL296UH090XV36C 7164951XC21-024-230 TXV 24000 21 15 CH35-42C SLP98UH090XV36C 7165576XC21-024-230 TXV 24000 17 13 CH35-42C 7164950XC21-024-230 TXV 23200 18 13 CR33-24 EL195DF045XE36B 5992561XC21-024-230 TXV 23200 18 13 CR33-24 EL296DF045XE36B 5992620XC21-024-230 TXV 23800 18 13.5 CR33-24 EL296DF045XV36B 5992558XC21-024-230 TXV 24200 18 13.5 CR33-24 SL280DF070V36A 5992418XC21-024-230 TXV 24000 18 13.5 CR33-24 SL280DF090V48B 5992419XC21-024-230 TXV 24800 19 14 CR33-30/36 EL195DF045XE36B 5992560XC21-024-230 TXV 24800 19 14 CR33-30/36 EL296DF045XE36B 5992619XC21-024-230 TXV 25600 20 14 CR33-30/36 EL296DF045XV36B 5992559XC21-024-230 TXV 26000 20 14 CR33-30/36 SL280DF070V36A 5992420XC21-024-230 TXV 26000 20 14 CR33-30/36 SL280DF090V48B 5992421XC21-024-230 TXV 25800 20 15 CR33-30/36 SLP98DF070XV36B 5992477XC21-024-230 TXV 24000 18 13.5 CR33-30/36 SLP98DF090XV36C 5992478XC21-024-230 TXV 25000 17 13 CR33-30/36 5992372XC21-024-230 TXV 23800 18 13.5 CX35-18/24A EL180UH045E36A 8248705XC21-024-230 TXV 24000 19 13.5 CX35-18/24A SL280UH070V36A 8248706XC21-024-230 TXV 24000 19 13.5 CX35-18/24A SL280UH070XV36A 8248707XC21-024-230 TXV 23600 16 12.5 CX35-18/24A 8248708XC21-024-230 TXV 24000 18 13.5 CX35-18/24B CBWMV-24B-040 8248709XC21-024-230 TXV 24000 18 13.5 CX35-18/24B EL296UH045XV36B 8248710XC21-024-230 TXV 24000 18 14 CX35-18/24B EL296UH070XV36B 8248711XC21-024-230 TXV 24000 18 14 CX35-18/24B SL280UH090V36B 8248712XC21-024-230 TXV 23800 18 13.5 CX35-18/24B SL280UH090V48B 8248713XC21-024-230 TXV 24000 18 13.5 CX35-18/24B SLP98UH070XV36B 8248714XC21-024-230 TXV 23600 16 12.5 CX35-18/24B 8248715XC21-024-230 TXV 24000 19 14 CX35-24A EL180UH045E36A 8249639XC21-024-230 TXV 24000 20 14 CX35-24A SL280UH070V36A 8249640XC21-024-230 TXV 24000 20 14 CX35-24A SL280UH070XV36A 8249641XC21-024-230 TXV 24000 17 13 CX35-24A 8249642XC21-024-230 TXV 24000 19 14 CX35-24B EL296UH045XV36B 8249643XC21-024-230 TXV 24000 20 14 CX35-24B EL296UH070XV36B 8249644XC21-024-230 TXV 24000 19 14 CX35-24B SL280UH090V48B 8249645XC21-024-230 TXV 24000 17 13 CX35-24B 8249646XC21-024-230 TXV 24000 19 14 CX35-30/36A EL180UH045E36A 8248716XC21-024-230 TXV 24000 20 14 CX35-30/36A SL280UH070V36A 8248717NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 20

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-024-230 TXV 24000 20 14 CX35-30/36A SL280UH070XV36A 8248718XC21-024-230 TXV 24000 17 13 CX35-30/36A 8248719XC21-024-230 TXV 24000 19 14 CX35-30/36B CBWMV-36B-070 8248720XC21-024-230 TXV 24000 19 14 CX35-30/36B EL296UH045XV36B 8248721XC21-024-230 TXV 24000 19 14 CX35-30/36B EL296UH070XV36B 8248722XC21-024-230 TXV 24000 20 14 CX35-30/36B SL280UH090V36B 8249647XC21-024-230 TXV 24000 19 14 CX35-30/36B SL280UH090V48B 8248723XC21-024-230 TXV 24000 20 14 CX35-30/36B SLP98UH070XV36B 8911946XC21-024-230 TXV 24000 17 13 CX35-30/36B 8248725XC21-024-230 TXV 24000 19 14 CX35-30/36C CBWMV-36C-090 8248726XC21-024-230 TXV 24000 20 14 CX35-30/36C EL296UH090XV36C 8248727XC21-024-230 TXV 24000 19 14 CX35-30/36C SLP98UH090XV36C 8911945XC21-024-230 TXV 24000 17 13 CX35-30/36C 8248729XC21-024-230 TXV 24000 19 14 CX35-30A EL180UH045E36A 8248730XC21-024-230 TXV 24000 20 14 CX35-30A SL280UH070V36A 8248731XC21-024-230 TXV 24000 20 14 CX35-30A SL280UH070XV36A 8248732XC21-024-230 TXV 24000 17 13 CX35-30A 8248733XC21-024-230 TXV 24000 20 14 CX35-30B EL296UH045XV36B 8248734XC21-024-230 TXV 24000 20 14 CX35-30B EL296UH070XV36B 8248735XC21-024-230 TXV 24000 20 14 CX35-30B SL280UH090V36B 10498615XC21-024-230 TXV 24000 19 14 CX35-30B SL280UH090XV48B 8248737XC21-024-230 TXV 24000 20 14 CX35-30B SLP98UH070XV36B 8248738XC21-024-230 TXV 24000 17 13 CX35-30B 8248739XC21-024-230 TXV 24000 19 14 CX35-36A EL180UH045E36A 8248740XC21-024-230 TXV 24000 20 14 CX35-36A SL280UH070V36A 8248741XC21-024-230 TXV 24000 20 14 CX35-36A SL280UH070XV36A 8248742XC21-024-230 TXV 24000 17 13 CX35-36A 8248743XC21-024-230 TXV 24000 20 14 CX35-36B EL296UH045XV36B 8248744XC21-024-230 TXV 24000 20 14 CX35-36B EL296UH070XV36B 8248745XC21-024-230 TXV 24000 21 14 CX35-36B SL280UH090V36B 8249648XC21-024-230 TXV 24000 19 14 CX35-36B SL280UH090V48B 8248746XC21-024-230 TXV 24000 20 14 CX35-36B SLP98UH070XV36B 8248747XC21-024-230 TXV 24000 17 13 CX35-36B 8248748XC21-024-230 TXV 24000 20 14 CX35-48B EL296UH045XV36B 8248749XC21-024-230 TXV 24000 20 14 CX35-48B EL296UH070XV36B 8248750XC21-024-230 TXV 26000 20 14.5 CX38-31B SL280UH090V36B 10559910XC21-036-230 TXV 35000 17 13 C35-30/36A EL180UH045E36A 8249649XC21-036-230 TXV 34000 16 12.2 C35-30/36A 8249650XC21-036-230 TXV 35000 18 13 C35-30/36B CBWMV-36B-070 8249651XC21-036-230 TXV 35000 18 13 C35-30/36B EL180UH070E36B 8249652XC21-036-230 TXV 35000 18 13 C35-30/36B EL180UH090E48B 8249653XC21-036-230 TXV 34800 17 12.5 C35-30/36B EL195UH045XE36B 8249654XC21-036-230 TXV 34800 17 12.5 C35-30/36B EL195UH070XE36B 8249655XC21-036-230 TXV 34800 17 12.5 C35-30/36B EL296UH045XE36B 8249657XC21-036-230 TXV 35000 18 13 C35-30/36B EL296UH045XV36B 8249656XC21-036-230 TXV 34800 17 12.5 C35-30/36B EL296UH070XE36B 8249659XC21-036-230 TXV 35000 18 13 C35-30/36B EL296UH070XV36B 8249658XC21-036-230 TXV 34800 18 13 C35-30/36B SL280UH090V36B 8249660NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 21

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 35000 18 13 C35-30/36B SL280UH090V48B 8249661XC21-036-230 TXV 35000 18 13 C35-30/36B SL280UH090XV48B 8249662XC21-036-230 TXV 36000 18 13 C35-30/36B SLP98UH070XV36B 8249663XC21-036-230 TXV 34000 16 12.2 C35-30/36B 8249664XC21-036-230 TXV 35000 18 13 C35-30/36C CBWMV-36C-090 8249665XC21-036-230 TXV 34800 17 13 C35-30/36C EL195UH090XE48C 8249666XC21-036-230 TXV 34800 17 13 C35-30/36C EL296UH090XE48C 8249669XC21-036-230 TXV 35000 18 13 C35-30/36C EL296UH090XV36C 8249667XC21-036-230 TXV 35000 18 13 C35-30/36C EL296UH090XV48C 8249668XC21-036-230 TXV 35600 18 13 C35-30/36C EL296UH090XV60C 8249670XC21-036-230 TXV 35200 18 13 C35-30/36C EL296UH110XV48C 8249671XC21-036-230 TXV 35000 18 13 C35-30/36C EL296UH110XV60C 8249672XC21-036-230 TXV 35000 18 13 C35-30/36C SLP98UH090XV36C 8249673XC21-036-230 TXV 35000 18 13 C35-30/36C SLP98UH090XV48C 8249674XC21-036-230 TXV 35600 18 13 C35-30/36C SLP98UH090XV60C 8249675XC21-036-230 TXV 35400 18 13.5 C35-30/36C SLP98UH110XV60C 8249676XC21-036-230 TXV 34000 16 12.2 C35-30/36C 8249677XC21-036-230 TXV 36000 18 13.5 C35-36A EL180UH045E36A 8249678XC21-036-230 TXV 36000 18 13 C35-36A SL280UH070V36A 8249679XC21-036-230 TXV 36000 18 13 C35-36A SL280UH070XV36A 8249680XC21-036-230 TXV 36000 16 12.5 C35-36A 8249681XC21-036-230 TXV 36000 18 13.5 C35-36B CBWMV-36B-070 8249682XC21-036-230 TXV 36000 18 13.5 C35-36B EL180UH070E36B 8249683XC21-036-230 TXV 36000 18 13.5 C35-36B EL180UH090E48B 8249684XC21-036-230 TXV 36000 18 13 C35-36B EL195UH045XE36B 8249685XC21-036-230 TXV 36000 18 13 C35-36B EL195UH070XE36B 8249686XC21-036-230 TXV 36000 18 13 C35-36B EL296UH045XE36B 8249688XC21-036-230 TXV 36000 18 13.5 C35-36B EL296UH045XV36B 8249687XC21-036-230 TXV 36000 18 13 C35-36B EL296UH070XE36B 8249690XC21-036-230 TXV 36000 18 13.5 C35-36B EL296UH070XV36B 8249689XC21-036-230 TXV 36000 19 13.5 C35-36B SL280UH090V36B 8249691XC21-036-230 TXV 36000 18 13.5 C35-36B SL280UH090V48B 8249692XC21-036-230 TXV 36000 18 13.5 C35-36B SL280UH090XV48B 8249693XC21-036-230 TXV 36000 18 13.5 C35-36B SLO185B124/141V60 8249694XC21-036-230 TXV 36000 19 13.5 C35-36B SLO185UF124/141V60 8249695XC21-036-230 TXV 36000 18 13.5 C35-36B SLP98UH070XV36B 8249696XC21-036-230 TXV 36000 16 12.5 C35-36B 8249697XC21-036-230 TXV 36000 18 13.5 C35-48B EL180UH070E36B 8249698XC21-036-230 TXV 36000 18 13.5 C35-48B EL180UH090E48B 8249699XC21-036-230 TXV 36000 18 13 C35-48B EL195UH045XE36B 8249700XC21-036-230 TXV 36000 18 13 C35-48B EL195UH070XE36B 8249701XC21-036-230 TXV 36000 18 13 C35-48B EL296UH045XE36B 8249703XC21-036-230 TXV 36000 18 13.5 C35-48B EL296UH045XV36B 8249702XC21-036-230 TXV 36000 18 13 C35-48B EL296UH070XE36B 8249705XC21-036-230 TXV 36000 18 13.5 C35-48B EL296UH070XV36B 8249704XC21-036-230 TXV 36000 18 14 C35-48B SL280UH090V36B 8249706XC21-036-230 TXV 36000 18 13.5 C35-48B SL280UH090V48B 8249707XC21-036-230 TXV 36000 18 13.5 C35-48B SL280UH090XV48B 8249708NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 22

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 36000 18 13.5 C35-48B SLP98UH070XV36B 8249709XC21-036-230 TXV 36000 16 12.5 C35-48B 8249710XC21-036-230 TXV 36000 18 13.5 C35-48C CBWMV-36C-090 8249711XC21-036-230 TXV 36000 18 13.5 C35-48C EL195UH090XE48C 8249712XC21-036-230 TXV 36000 18 13.5 C35-48C EL296UH090XE48C 8249715XC21-036-230 TXV 36000 18 13.5 C35-48C EL296UH090XV36C 8249713XC21-036-230 TXV 36000 19 14 C35-48C EL296UH090XV48C 8249714XC21-036-230 TXV 36000 19 13.5 C35-48C EL296UH090XV60C 8249716XC21-036-230 TXV 36000 19 14 C35-48C EL296UH110XV48C 8249717XC21-036-230 TXV 36000 19 14 C35-48C EL296UH110XV60C 8249718XC21-036-230 TXV 36000 19 14 C35-48C SL280UH090V60C 8249719XC21-036-230 TXV 36000 19 14 C35-48C SL280UH090XV60C 8249720XC21-036-230 TXV 36000 18 13.5 C35-48C SL280UH110V60C 8249721XC21-036-230 TXV 36000 18 13.5 C35-48C SL280UH110XV60C 8249722XC21-036-230 TXV 36000 18 13.5 C35-48C SLO185B124/141V60 8249723XC21-036-230 TXV 36000 18 13.5 C35-48C SLO185UF124/141V60 8249724XC21-036-230 TXV 36000 18 13.5 C35-48C SLP98UH090XV36C 8249725XC21-036-230 TXV 36000 18 14 C35-48C SLP98UH090XV48C 8249726XC21-036-230 TXV 36000 19 13.5 C35-48C SLP98UH090XV60C 8249727XC21-036-230 TXV 36000 19 14 C35-48C SLP98UH110XV60C 8249728XC21-036-230 TXV 36000 16 12.5 C35-48C 8249729XC21-036-230 TXV 36000 18 13.5 C35-50/60C EL195UH090XE48C 8249730XC21-036-230 TXV 36000 18 13.5 C35-50/60C EL296UH090XE48C 8249733XC21-036-230 TXV 36000 18 13.5 C35-50/60C EL296UH090XV36C 8249731XC21-036-230 TXV 36000 19 13.5 C35-50/60C EL296UH090XV48C 8249732XC21-036-230 TXV 36000 19 13.5 C35-50/60C EL296UH090XV60C 8249734XC21-036-230 TXV 36000 19 13.5 C35-50/60C EL296UH110XV48C 8249735XC21-036-230 TXV 36000 18 13.5 C35-50/60C SLO185B124/141V60 8249736XC21-036-230 TXV 36000 18 13.5 C35-50/60C SLO185UF124/141V60 8249737XC21-036-230 TXV 36000 18 13.5 C35-50/60C SLP98UH090XV36C 8249738XC21-036-230 TXV 36000 18 13.5 C35-50/60C SLP98UH090XV48C 8249739XC21-036-230 TXV 36000 19 13.5 C35-50/60C SLP98UH090XV60C 8249740XC21-036-230 TXV 36000 16 12.5 C35-50/60C 8249741XC21-036-230 TXV 36000 19 14 C35-60C SLO185B124/141V60 8249742XC21-036-230 TXV 36000 19 13.5 C35-60C SLO185UF124/141V60 8249743XC21-036-230 TXV 36000 19 14 C35-60D SLO185B124/141V60 8249744XC21-036-230 TXV 36000 19 13.5 C35-60D SLO185UF124/141V60 8249745XC21-036-230 TXV 36000 18 13 CBA27UHE-036 10259511XC21-036-230 TXV 36000 19 14 CBA27UHE-042 10259512XC21-036-230 TXV 36000 18 13.5 CBX27UH-036 5991575XC21-036-230 TXV 37200 19 14 CBX27UH-042 5991576XC21-036-230 TXV 35200 17 12.5 CBX32M-030 5991571XC21-036-230 TXV 35600 17 12.5 CBX32M-036 5991572XC21-036-230 TXV 35800 17 12.5 CBX32M-042 5991573XC21-036-230 TXV 36800 17 13.5 CBX32M-048 5991574XC21-036-230 TXV 35600 18 13 CBX32MV-024/030 5991577XC21-036-230 TXV 35600 19 13.5 CBX32MV-036 5991578XC21-036-230 TXV 37200 19.5 14.2 CBX32MV-048 5991579NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 23

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 36000 19 13.5 CBX40UHV-030 5991580XC21-036-230 TXV 35600 18 13.5 CBX40UHV-036 5991581XC21-036-230 TXV 37200 19 14 CBX40UHV-042 5991582XC21-036-230 TXV 37200 19 14.2 CBX40UHV-048 5991583XC21-036-230 TXV 33000 16 12.5 CH23-31 EL180UH090E48B 5991992XC21-036-230 TXV 32800 16 12.5 CH23-31 EL195UH090XE48C 5991747XC21-036-230 TXV 33200 17 12.5 CH23-31 EL296UH045XV36B 5991628XC21-036-230 TXV 33200 17 12.5 CH23-31 EL296UH070XV36B 5991635XC21-036-230 TXV 32800 16 12.5 CH23-31 EL296UH090XE48C 5991924XC21-036-230 TXV 33200 17 12.5 CH23-31 EL296UH090XV36C 5991661XC21-036-230 TXV 33000 17 12.5 CH23-31 EL296UH090XV48C 5991679XC21-036-230 TXV 33200 17 12.5 CH23-31 EL296UH110XV48C 5991697XC21-036-230 TXV 33200 17 12.5 CH23-31 SL280UH070V36A 5991528XC21-036-230 TXV 33200 17 12.5 CH23-31 SL280UH070XV36A 5991849XC21-036-230 TXV 33000 17 13 CH23-31 SL280UH090V36B 5991529XC21-036-230 TXV 32800 17 12.5 CH23-31 SLP98UH070XV36B 5991530XC21-036-230 TXV 35200 17 13 CH23-41 EL180UH045E36A 5992016XC21-036-230 TXV 35200 18 13 CH23-41 EL180UH070E36B 5992003XC21-036-230 TXV 35200 18 13 CH23-41 EL180UH090E48B 5991993XC21-036-230 TXV 35000 17 12.5 CH23-41 EL195UH045XE36B 5991715XC21-036-230 TXV 35000 17 12.5 CH23-41 EL195UH070XE36B 5991730XC21-036-230 TXV 35000 17 13 CH23-41 EL195UH090XE48C 5991748XC21-036-230 TXV 35000 17 12.5 CH23-41 EL296UH045XE36B 5991965XC21-036-230 TXV 35200 18 13 CH23-41 EL296UH045XV36B 5991629XC21-036-230 TXV 35000 17 12.5 CH23-41 EL296UH070XE36B 5991943XC21-036-230 TXV 35200 18 13 CH23-41 EL296UH070XV36B 5991636XC21-036-230 TXV 35000 17 13 CH23-41 EL296UH090XE48C 5991925XC21-036-230 TXV 35400 18 13.5 CH23-41 EL296UH090XV36C 5991662XC21-036-230 TXV 35200 18 13.5 CH23-41 EL296UH090XV48C 5991680XC21-036-230 TXV 35400 18 13.5 CH23-41 EL296UH110XV48C 5991973XC21-036-230 TXV 35400 18 13 CH23-41 SL280UH070V36A 5991531XC21-036-230 TXV 35400 18 13 CH23-41 SL280UH070XV36A 5991850XC21-036-230 TXV 35200 18 13.5 CH23-41 SL280UH090V36B 5991532XC21-036-230 TXV 35000 18 13.5 CH23-41 SLP98UH070XV36B 5991533XC21-036-230 TXV 35000 18 13.5 CH23-41 SLP98UH090XV36C 5991534XC21-036-230 TXV 35200 18 13.5 CH23-41 SLP98UH090XV48C 5991535XC21-036-230 TXV 35400 18 13 CH23-51 EL180UH070E36B 5992004XC21-036-230 TXV 35200 18 13 CH23-51 EL180UH090E48B 5991994XC21-036-230 TXV 35000 17 12.5 CH23-51 EL195UH045XE36B 5991716XC21-036-230 TXV 35200 17 12.5 CH23-51 EL195UH070XE36B 5991731XC21-036-230 TXV 35200 18 13 CH23-51 EL195UH090XE48C 5991749XC21-036-230 TXV 35000 17 12.5 CH23-51 EL296UH045XE36B 5991966XC21-036-230 TXV 35400 18 13 CH23-51 EL296UH045XV36B 5991630XC21-036-230 TXV 35200 17 12.5 CH23-51 EL296UH070XE36B 5991944XC21-036-230 TXV 35400 18 13 CH23-51 EL296UH070XV36B 5991637XC21-036-230 TXV 35200 18 13 CH23-51 EL296UH090XE48C 5991926XC21-036-230 TXV 35600 18 13.5 CH23-51 EL296UH090XV36C 5991663XC21-036-230 TXV 35400 18 13.5 CH23-51 EL296UH090XV48C 5991681NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 24

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 35600 19 13.5 CH23-51 EL296UH110XV48C 5991974XC21-036-230 TXV 35400 18 13 CH23-51 SL280UH070V36A 5991536XC21-036-230 TXV 35400 18 13 CH23-51 SL280UH070XV36A 5991851XC21-036-230 TXV 35200 18 13.5 CH23-51 SL280UH090V36B 5991537XC21-036-230 TXV 35200 18 13.5 CH23-51 SLP98UH070XV36B 5991538XC21-036-230 TXV 35000 18 13.5 CH23-51 SLP98UH090XV36C 5991539XC21-036-230 TXV 35400 18 13.5 CH23-51 SLP98UH090XV48C 5991540XC21-036-230 TXV 36200 18 13 CH33-31 EL180UH045E36A 5992013XC21-036-230 TXV 34800 18 13 CH33-36 EL296UH045XV36B 5991616XC21-036-230 TXV 35000 18 13 CH33-36 EL296UH070XV36B 5991631XC21-036-230 TXV 35600 18 13.5 CH33-36 EL296UH090XV36C 5991656XC21-036-230 TXV 35400 18 13.5 CH33-36 EL296UH090XV48C 5991674XC21-036-230 TXV 34800 18 13.5 CH33-36 SL280UH090V36B 5991541XC21-036-230 TXV 35000 18 13 CH33-36 SL280UH090V48B 5991542XC21-036-230 TXV 35000 18 13 CH33-36 SL280UH090XV48B 5991843XC21-036-230 TXV 34600 18 13 CH33-36 SLP98UH070XV36B 5991543XC21-036-230 TXV 35000 18 13.5 CH33-36 SLP98UH090XV36C 5991544XC21-036-230 TXV 35400 18 13.5 CH33-36 SLP98UH090XV48C 5991545XC21-036-230 TXV 34800 17 12.5 CH33-36A EL180UH045E36A 5992014XC21-036-230 TXV 35000 18 13 CH33-36A SL280UH070V36A 5991853XC21-036-230 TXV 35000 18 13 CH33-36A SL280UH070XV36A 5991852XC21-036-230 TXV 35000 18 13 CH33-36B EL180UH070E36B 5991998XC21-036-230 TXV 34800 18 13 CH33-36B EL180UH090E48B 5991988XC21-036-230 TXV 34600 17 12.5 CH33-36B EL195UH045XE36B 5991710XC21-036-230 TXV 34800 17 12.5 CH33-36B EL195UH070XE36B 5991725XC21-036-230 TXV 35200 18 13 CH33-36B EL195UH090XE48C 5991742XC21-036-230 TXV 34600 17 12.5 CH33-36B EL296UH045XE36B 5991960XC21-036-230 TXV 34800 17 12.5 CH33-36B EL296UH070XE36B 5991938XC21-036-230 TXV 35200 18 13 CH33-36B EL296UH090XE48C 5991919XC21-036-230 TXV 35600 18 13.5 CH33-36C EL296UH110XV48C 5991692XC21-036-230 TXV 35000 16 12.5 CH33-36C 5991450XC21-036-230 TXV 36000 18 13 CH33-42 EL180UH070E36B 5991999XC21-036-230 TXV 35800 18 13.5 CH33-42 EL180UH090E48B 5991989XC21-036-230 TXV 35600 17 12.5 CH33-42 EL195UH045XE36B 5991711XC21-036-230 TXV 35800 17 13 CH33-42 EL195UH070XE36B 5991726XC21-036-230 TXV 35600 17 12.5 CH33-42 EL296UH045XE36B 5991961XC21-036-230 TXV 35800 18 13 CH33-42 EL296UH045XV36B 5991617XC21-036-230 TXV 35800 17 13 CH33-42 EL296UH070XE36B 5991939XC21-036-230 TXV 35800 18 13 CH33-42 EL296UH070XV36B 5991632XC21-036-230 TXV 35800 18 13.5 CH33-42 SL280UH090V36B 5991546XC21-036-230 TXV 36000 18 13.5 CH33-42 SL280UH090V48B 5991547XC21-036-230 TXV 36000 18 13.5 CH33-42 SL280UH090XV48B 5991844XC21-036-230 TXV 35600 18 13 CH33-42 SLP98UH070XV36B 5991548XC21-036-230 TXV 35600 18 13.5 CH33-42 SLP98UH090XV36C 5991549XC21-036-230 TXV 35800 18 13.5 CH33-42 SLP98UH090XV48C 5991550XC21-036-230 TXV 35600 16 12.5 CH33-42 5991451XC21-036-230 TXV 37400 18 13.5 CH33-43 EL296UH045XV36B 5991618XC21-036-230 TXV 37400 18 13.5 CH33-43 EL296UH070XV36B 5991633NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 25

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 37000 19 14 CH33-43 EL296UH090XV36C 5991657XC21-036-230 TXV 36600 19 14 CH33-43 EL296UH090XV48C 5991675XC21-036-230 TXV 37400 19 14 CH33-43 EL296UH090XV60C 5991811XC21-036-230 TXV 37200 19 14 CH33-43 EL296UH110XV60C 5991815XC21-036-230 TXV 37200 19 14 CH33-43 SL280UH090V36B 5991551XC21-036-230 TXV 37400 19 14 CH33-43 SL280UH090V48B 5991552XC21-036-230 TXV 37400 19 14 CH33-43 SL280UH090XV48B 5991845XC21-036-230 TXV 37000 19 13.5 CH33-43 SLP98UH070XV36B 5991553XC21-036-230 TXV 36400 19 14 CH33-43 SLP98UH090XV36C 5991554XC21-036-230 TXV 36600 19 14 CH33-43 SLP98UH090XV48C 5991555XC21-036-230 TXV 37400 19.2 14 CH33-43 SLP98UH090XV60C 5991608XC21-036-230 TXV 37200 19.2 14 CH33-43 SLP98UH110XV60C 5991609XC21-036-230 TXV 37600 19 13.5 CH33-43B EL180UH070E36B 5992000XC21-036-230 TXV 37400 19 14 CH33-43B EL180UH090E48B 5991990XC21-036-230 TXV 37200 18 13 CH33-43B EL195UH045XE36B 5991712XC21-036-230 TXV 37200 18 13.5 CH33-43B EL195UH070XE36B 5991727XC21-036-230 TXV 37200 18 13 CH33-43B EL296UH045XE36B 5991962XC21-036-230 TXV 37200 18 13.5 CH33-43B EL296UH070XE36B 5991940XC21-036-230 TXV 37000 16 13 CH33-43B 5991452XC21-036-230 TXV 36400 18 13.5 CH33-43C EL195UH090XE48C 5991743XC21-036-230 TXV 36400 18 13.5 CH33-43C EL296UH090XE48C 5991920XC21-036-230 TXV 37000 19 14 CH33-43C EL296UH110XV48C 5991693XC21-036-230 TXV 36400 16 12.5 CH33-43C 5991453XC21-036-230 TXV 36600 18 13.5 CH33-44/48 EL180UH070E36B 5992001XC21-036-230 TXV 36400 18 13.5 CH33-44/48 EL180UH090E48B 5991991XC21-036-230 TXV 36200 18 13 CH33-44/48 EL195UH045XE36B 5991713XC21-036-230 TXV 36400 18 13 CH33-44/48 EL195UH070XE36B 5991728XC21-036-230 TXV 36200 18 13 CH33-44/48 EL296UH045XE36B 5991963XC21-036-230 TXV 36400 18 13 CH33-44/48 EL296UH045XV36B 5991619XC21-036-230 TXV 36400 18 13 CH33-44/48 EL296UH070XE36B 5991941XC21-036-230 TXV 36400 18 13 CH33-44/48 EL296UH070XV36B 5991634XC21-036-230 TXV 36200 18 13.5 CH33-44/48 SL280UH090V36B 5991556XC21-036-230 TXV 36400 18 13.5 CH33-44/48 SL280UH090V48B 5991557XC21-036-230 TXV 36400 18 13.5 CH33-44/48 SL280UH090XV48B 5991846XC21-036-230 TXV 36200 18 13.5 CH33-44/48 SLP98UH070XV36B 5991558XC21-036-230 TXV 36000 16 12.5 CH33-44/48 5991454XC21-036-230 TXV 36600 19 13.5 CH33-48 EL296UH090XV36C 5991658XC21-036-230 TXV 36400 19 14 CH33-48 EL296UH090XV48C 5991676XC21-036-230 TXV 37200 19 13.5 CH33-48 EL296UH090XV60C 5991812XC21-036-230 TXV 37000 19 14 CH33-48 EL296UH110XV60C 5991816XC21-036-230 TXV 37200 19 13.5 CH33-48 SL280UH090V60C 5991559XC21-036-230 TXV 37200 19 13.5 CH33-48 SL280UH090XV60C 5991821XC21-036-230 TXV 37000 19 13.5 CH33-48 SL280UH110V60C 5991560XC21-036-230 TXV 37000 19 13.5 CH33-48 SL280UH110XV60C 5991830XC21-036-230 TXV 36200 19 13.5 CH33-48 SLP98UH090XV36C 5991561XC21-036-230 TXV 36400 18 14 CH33-48 SLP98UH090XV48C 5991562XC21-036-230 TXV 37200 19.2 13.7 CH33-48 SLP98UH090XV60C 5991610XC21-036-230 TXV 37000 19.2 14 CH33-48 SLP98UH110XV60C 5991611NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 26

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 36200 16 12.5 CH33-48 5991455XC21-036-230 TXV 36200 18 13.5 CH33-48C EL195UH090XE48C 5991744XC21-036-230 TXV 36200 18 13.5 CH33-48C EL296UH090XE48C 5991921XC21-036-230 TXV 36800 19 14 CH33-48C EL296UH110XV48C 5991694XC21-036-230 TXV 37000 18 14 CH33-49 EL195UH090XE48C 5991745XC21-036-230 TXV 37000 18 14 CH33-49 EL296UH090XE48C 5991922XC21-036-230 TXV 37400 19 14 CH33-49 EL296UH090XV36C 5991659XC21-036-230 TXV 37200 19 14 CH33-49 EL296UH090XV48C 5991677XC21-036-230 TXV 38000 19 14 CH33-49 EL296UH090XV60C 5991813XC21-036-230 TXV 37400 19 14 CH33-49 EL296UH110XV48C 5991695XC21-036-230 TXV 37800 19 14 CH33-49 EL296UH110XV60C 5991817XC21-036-230 TXV 38000 19 13.5 CH33-49 SL280UH090V60C 5991563XC21-036-230 TXV 38000 19 13.5 CH33-49 SL280UH090XV60C 5991822XC21-036-230 TXV 37600 19 13.5 CH33-49 SL280UH110V60C 5991564XC21-036-230 TXV 37600 19 13.5 CH33-49 SL280UH110XV60C 5991831XC21-036-230 TXV 36800 19 14 CH33-49 SLP98UH090XV36C 5991565XC21-036-230 TXV 37200 19 14 CH33-49 SLP98UH090XV48C 5991566XC21-036-230 TXV 38000 19.5 14 CH33-49 SLP98UH090XV60C 5991612XC21-036-230 TXV 37800 19.5 14.2 CH33-49 SLP98UH110XV60C 5991613XC21-036-230 TXV 36800 16 13 CH33-49 5991456XC21-036-230 TXV 36800 18 13.5 CH33-50/60C EL195UH090XE48C 5991746XC21-036-230 TXV 36800 18 13.5 CH33-50/60C EL296UH090XE48C 5991923XC21-036-230 TXV 37200 19 14 CH33-50/60C EL296UH090XV36C 5991660XC21-036-230 TXV 37000 19 14 CH33-50/60C EL296UH090XV48C 5991678XC21-036-230 TXV 37800 19 14 CH33-50/60C EL296UH090XV60C 5991814XC21-036-230 TXV 37200 19 14 CH33-50/60C EL296UH110XV48C 5991696XC21-036-230 TXV 37600 19 14 CH33-50/60C EL296UH110XV60C 5991818XC21-036-230 TXV 37800 19 13.5 CH33-50/60C SL280UH090V60C 5991567XC21-036-230 TXV 37800 19 13.5 CH33-50/60C SL280UH090XV60C 5991823XC21-036-230 TXV 37400 19 13.5 CH33-50/60C SL280UH110V60C 5991568XC21-036-230 TXV 37400 19 13.5 CH33-50/60C SL280UH110XV60C 5991832XC21-036-230 TXV 36600 19 14 CH33-50/60C SLP98UH090XV36C 5991569XC21-036-230 TXV 37000 19 14 CH33-50/60C SLP98UH090XV48C 5991570XC21-036-230 TXV 37800 19.5 14 CH33-50/60C SLP98UH090XV60C 5991614XC21-036-230 TXV 37600 19.5 14.2 CH33-50/60C SLP98UH110XV60C 5991615XC21-036-230 TXV 36600 16 13 CH33-50/60C 5991457XC21-036-230 TXV 36000 18 13 CH35-30A EL180UH045E36A 7164813XC21-036-230 TXV 35800 16 12.5 CH35-30A 7164818XC21-036-230 TXV 36000 16 12.5 CH35-30B 7164819XC21-036-230 TXV 35000 17 13 CH35-36A EL180UH045E36A 7164814XC21-036-230 TXV 35200 18 13 CH35-36A SL280UH070V36A 7164816XC21-036-230 TXV 35200 18 13 CH35-36A SL280UH070XV36A 7164815XC21-036-230 TXV 35200 18 13 CH35-36B EL180UH070E36B 7164826XC21-036-230 TXV 35000 18 13 CH35-36B EL180UH090E48B 7164827XC21-036-230 TXV 34800 17 12.5 CH35-36B EL195UH045XE36B 7164821XC21-036-230 TXV 34800 17 12.5 CH35-36B EL195UH070XE36B 7164823XC21-036-230 TXV 34800 17 12.5 CH35-36B EL296UH045XE36B 7165577XC21-036-230 TXV 34800 17 12.5 CH35-36B EL296UH045XV36B 7164822NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 27

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 34800 17 12.5 CH35-36B EL296UH070XE36B 7164824XC21-036-230 TXV 35000 18 13 CH35-36B EL296UH070XV36B 7164825XC21-036-230 TXV 34800 18 13 CH35-36B SL280UH090V36B 7164828XC21-036-230 TXV 35200 18 13 CH35-36B SL280UH090V48B 7164829XC21-036-230 TXV 35200 18 13 CH35-36B SL280UH090XV48B 7164830XC21-036-230 TXV 34800 18 13 CH35-36B SLP98UH070XV36B 7164831XC21-036-230 TXV 35200 18 13 CH35-36C EL195UH090XE48C 7164833XC21-036-230 TXV 35200 18 13 CH35-36C EL296UH090XE48C 7165578XC21-036-230 TXV 35600 18 13 CH35-36C EL296UH090XV36C 7164835XC21-036-230 TXV 35200 18 13 CH35-36C EL296UH090XV48C 7164834XC21-036-230 TXV 35600 18 13 CH35-36C EL296UH110XV48C 7164836XC21-036-230 TXV 35200 18 13 CH35-36C SLP98UH090XV36C 7164837XC21-036-230 TXV 35400 18 13 CH35-36C SLP98UH090XV48C 7164838XC21-036-230 TXV 36000 19 13 CH35-42B EL180UH070E36B 7164846XC21-036-230 TXV 36000 19 13 CH35-42B EL180UH090E48B 7164847XC21-036-230 TXV 36000 18 13 CH35-42B EL195UH045XE36B 7164840XC21-036-230 TXV 36000 18 13 CH35-42B EL195UH070XE36B 7164842XC21-036-230 TXV 36000 18 13 CH35-42B EL296UH045XE36B 7164841XC21-036-230 TXV 36000 18 13 CH35-42B EL296UH045XV36B 7164844XC21-036-230 TXV 36000 18 13 CH35-42B EL296UH070XE36B 7164843XC21-036-230 TXV 36000 18 13 CH35-42B EL296UH070XV36B 7164845XC21-036-230 TXV 36000 19 14 CH35-42B SL280UH090V36B 7164848XC21-036-230 TXV 36000 19 13 CH35-42B SL280UH090V48B 7164849XC21-036-230 TXV 36000 19 13 CH35-42B SL280UH090XV48B 7164850XC21-036-230 TXV 36000 19 13 CH35-42B SLP98UH070XV36B 7164851XC21-036-230 TXV 36000 17 13 CH35-42B 7164839XC21-036-230 TXV 36000 18 13 CH35-42C EL195UH090XE48C 7164853XC21-036-230 TXV 36000 18 13 CH35-42C EL296UH090XE48C 7164854XC21-036-230 TXV 36000 19 13 CH35-42C EL296UH090XV36C 7164855XC21-036-230 TXV 36000 19 13 CH35-42C EL296UH090XV48C 7164856XC21-036-230 TXV 36000 19 13 CH35-42C EL296UH090XV60C 7164857XC21-036-230 TXV 36000 19 14 CH35-42C EL296UH110XV48C 7164858XC21-036-230 TXV 36000 19 14 CH35-42C EL296UH110XV60C 7164859XC21-036-230 TXV 36000 19 13 CH35-42C SLP98UH090XV36C 7164860XC21-036-230 TXV 36000 19 13 CH35-42C SLP98UH090XV48C 7164861XC21-036-230 TXV 36000 19 13 CH35-42C SLP98UH090XV60C 7164862XC21-036-230 TXV 36000 19 14 CH35-42C SLP98UH110XV60C 7164863XC21-036-230 TXV 36000 16 12.5 CH35-42C 7164852XC21-036-230 TXV 36000 18 13 CH35-48B EL180UH070E36B 7164871XC21-036-230 TXV 36000 18 13 CH35-48B EL180UH090E48B 7164872XC21-036-230 TXV 36000 18 13 CH35-48B EL195UH045XE36B 7164865XC21-036-230 TXV 36000 18 13 CH35-48B EL195UH070XE36B 7164867XC21-036-230 TXV 36000 18 13 CH35-48B EL296UH045XE36B 7164866XC21-036-230 TXV 36000 18 13 CH35-48B EL296UH045XV36B 7164869XC21-036-230 TXV 36000 18 13 CH35-48B EL296UH070XE36B 7164868XC21-036-230 TXV 36000 18 13 CH35-48B EL296UH070XV36B 7164870XC21-036-230 TXV 36000 18 13 CH35-48B SL280UH090V36B 7164873XC21-036-230 TXV 36000 18 13 CH35-48B SL280UH090V48B 7164874NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 28

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 36000 18 13 CH35-48B SL280UH090XV48B 7164875XC21-036-230 TXV 36000 18 13 CH35-48B SLP98UH070XV36B 7164876XC21-036-230 TXV 36000 16 12.5 CH35-48B 7164864XC21-036-230 TXV 36000 18 13 CH35-48C EL195UH090XE48C 7164878XC21-036-230 TXV 36000 18 13 CH35-48C EL296UH090XE48C 7164879XC21-036-230 TXV 36000 19 13 CH35-48C EL296UH090XV36C 7164880XC21-036-230 TXV 36000 19 13 CH35-48C EL296UH090XV48C 7164881XC21-036-230 TXV 36000 19 13 CH35-48C EL296UH090XV60C 7164882XC21-036-230 TXV 36000 19 13 CH35-48C EL296UH110XV48C 7164883XC21-036-230 TXV 36000 19 13 CH35-48C EL296UH110XV60C 7164884XC21-036-230 TXV 36000 19 14 CH35-48C SL280UH090V60C 7164885XC21-036-230 TXV 36000 19 14 CH35-48C SL280UH090XV60C 7164886XC21-036-230 TXV 36000 19 13 CH35-48C SL280UH110V60C 7164887XC21-036-230 TXV 36000 19 13 CH35-48C SL280UH110XV60C 7164888XC21-036-230 TXV 36000 19 13 CH35-48C SLP98UH090XV36C 7164889XC21-036-230 TXV 36000 18 13 CH35-48C SLP98UH090XV48C 7164890XC21-036-230 TXV 36000 19 13 CH35-48C SLP98UH090XV60C 7164891XC21-036-230 TXV 36000 19 13 CH35-48C SLP98UH110XV60C 7164892XC21-036-230 TXV 36000 16 12.5 CH35-48C 7164877XC21-036-230 TXV 36000 18 13 CH35-51C EL195UH090XE48C 7164894XC21-036-230 TXV 36000 18 13 CH35-51C EL296UH090XE48C 7164895XC21-036-230 TXV 36000 19 14 CH35-51C EL296UH090XV36C 7164896XC21-036-230 TXV 36000 19 14 CH35-51C EL296UH090XV48C 7164897XC21-036-230 TXV 36000 19 14 CH35-51C EL296UH090XV60C 7164898XC21-036-230 TXV 36000 19 14 CH35-51C EL296UH110XV48C 7164899XC21-036-230 TXV 36000 19 14 CH35-51C EL296UH110XV60C 7164900XC21-036-230 TXV 36000 19 14 CH35-51C SL280UH090V60C 7164901XC21-036-230 TXV 36000 19 14 CH35-51C SL280UH090XV60C 7164902XC21-036-230 TXV 36000 19 14 CH35-51C SL280UH110V60C 7164903XC21-036-230 TXV 36000 19 14 CH35-51C SL280UH110XV60C 7164904XC21-036-230 TXV 36000 19 13 CH35-51C SLP98UH090XV36C 7164905XC21-036-230 TXV 36000 19 14 CH35-51C SLP98UH090XV48C 7165579XC21-036-230 TXV 36000 19 14 CH35-51C SLP98UH090XV60C 7164906XC21-036-230 TXV 36000 19 14 CH35-51C SLP98UH110XV60C 7164907XC21-036-230 TXV 36000 16 13 CH35-51C 7164893XC21-036-230 TXV 35200 18 13.5 CR33-30/36 EL180DF070E36B 5992007XC21-036-230 TXV 35400 17 12.5 CR33-30/36 EL195DF045XE36B 5991788XC21-036-230 TXV 35200 18 13 CR33-30/36 EL195DF070XE48B 5991791XC21-036-230 TXV 35400 18 13 CR33-30/36 EL195DF090XE48C 5991911XC21-036-230 TXV 35400 17 12.5 CR33-30/36 EL296DF045XE36B 5991927XC21-036-230 TXV 35400 18 13 CR33-30/36 EL296DF045XV36B 5991792XC21-036-230 TXV 35200 18 13 CR33-30/36 EL296DF070XE48B 5991930XC21-036-230 TXV 35400 17 12.5 CR33-30/36 EL296DF070XV48B 5991794XC21-036-230 TXV 35400 18 13 CR33-30/36 EL296DF090XE48C 5991931XC21-036-230 TXV 35400 18 13 CR33-30/36 SL280DF090V48B 5991519XC21-036-230 TXV 35200 18 13 CR33-30/36 SLP98DF070XV36B 5991520XC21-036-230 TXV 35200 18 13 CR33-30/36 SLP98DF090XV36C 5991521XC21-036-230 TXV 35200 18 13.5 CR33-30/36 SLP98DF090XV48C 5991522NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 29

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 35200 16 12.5 CR33-30/36 5991443XC21-036-230 TXV 35600 18 13.5 CR33-48 EL180DF070E36B 5992008XC21-036-230 TXV 35800 17 12.5 CR33-48 EL195DF045XE36B 5991789XC21-036-230 TXV 35800 18 13.5 CR33-48 EL195DF070XE48B 5991790XC21-036-230 TXV 35800 18 13.5 CR33-48 EL195DF090XE48C 5991912XC21-036-230 TXV 35800 17 12.5 CR33-48 EL296DF045XE36B 5991928XC21-036-230 TXV 36000 18 13 CR33-48 EL296DF045XV36B 5991793XC21-036-230 TXV 35800 18 13.5 CR33-48 EL296DF070XE48B 5991929XC21-036-230 TXV 36000 18 13 CR33-48 EL296DF070XV48B 5991795XC21-036-230 TXV 35800 18 13.5 CR33-48 EL296DF090XE48C 5991932XC21-036-230 TXV 35800 18 13.5 CR33-48 SL280DF090V48B 5991523XC21-036-230 TXV 36600 19 14 CR33-48 SL280DF090V60C 5991868XC21-036-230 TXV 35800 18 13.5 CR33-48 SLP98DF070XV36B 5991524XC21-036-230 TXV 35800 18 13.5 CR33-48 SLP98DF090XV36C 5991525XC21-036-230 TXV 36200 19 13.5 CR33-48 SLP98DF090XV48C 5991526XC21-036-230 TXV 35600 16 12.5 CR33-48 5991444XC21-036-230 TXV 36000 18 13.5 CR33-50/60 EL195DF090XE48C 5991913XC21-036-230 TXV 36000 18 13.5 CR33-50/60 EL296DF090XE48C 5991933XC21-036-230 TXV 35800 18 13.5 CR33-50/60 SLP98DF090XV36C 5991527XC21-036-230 TXV 35600 16 12.5 CR33-50/60 5991445XC21-036-230 TXV 35000 17 13 CX35-30/36A EL180UH045E36A 8249746XC21-036-230 TXV 34000 16 12.2 CX35-30/36A 8249747XC21-036-230 TXV 35000 18 13 CX35-30/36B CBWMV-36B-070 8249748XC21-036-230 TXV 35000 18 13 CX35-30/36B EL180UH070E36B 8249749XC21-036-230 TXV 35000 18 13 CX35-30/36B EL180UH090E48B 8249750XC21-036-230 TXV 34800 17 12.5 CX35-30/36B EL195UH045XE36B 8249751XC21-036-230 TXV 34800 17 12.5 CX35-30/36B EL195UH070XE36B 8249752XC21-036-230 TXV 34800 17 12.5 CX35-30/36B EL296UH045XE36B 8249754XC21-036-230 TXV 35000 18 13 CX35-30/36B EL296UH045XV36B 8249753XC21-036-230 TXV 34800 17 12.5 CX35-30/36B EL296UH070XE36B 8249756XC21-036-230 TXV 35000 18 13 CX35-30/36B EL296UH070XV36B 8249755XC21-036-230 TXV 34800 18 13 CX35-30/36B SL280UH090V36B 8249757XC21-036-230 TXV 35000 18 13 CX35-30/36B SL280UH090V48B 8249758XC21-036-230 TXV 35000 18 13 CX35-30/36B SL280UH090XV48B 8249759XC21-036-230 TXV 34600 18 13 CX35-30/36B SLP98UH070XV36B 8249760XC21-036-230 TXV 34000 16 12.2 CX35-30/36B 8249761XC21-036-230 TXV 35000 18 13 CX35-30/36C CBWMV-36C-090 8249762XC21-036-230 TXV 34800 17 13 CX35-30/36C EL195UH090XE48C 8249763XC21-036-230 TXV 34800 17 13 CX35-30/36C EL296UH090XE48C 8249766XC21-036-230 TXV 35000 18 13 CX35-30/36C EL296UH090XV36C 8249764XC21-036-230 TXV 35000 18 13 CX35-30/36C EL296UH090XV48C 8249765XC21-036-230 TXV 35600 18 13 CX35-30/36C EL296UH090XV60C 8249767XC21-036-230 TXV 35200 18 13 CX35-30/36C EL296UH110XV48C 8249768XC21-036-230 TXV 35000 18 13 CX35-30/36C EL296UH110XV60C 8249769XC21-036-230 TXV 35000 18 13 CX35-30/36C SLP98UH090XV36C 8249770XC21-036-230 TXV 35000 18 13 CX35-30/36C SLP98UH090XV48C 8249771XC21-036-230 TXV 35600 18 13 CX35-30/36C SLP98UH090XV60C 8249772XC21-036-230 TXV 35400 18 13.5 CX35-30/36C SLP98UH110XV60C 8249773NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 30

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 34000 16 12.2 CX35-30/36C 8249774XC21-036-230 TXV 36000 18 13.5 CX35-36A EL180UH045E36A 8249775XC21-036-230 TXV 36000 18 13 CX35-36A SL280UH070V36A 8249776XC21-036-230 TXV 36000 18 13 CX35-36A SL280UH070XV36A 8249777XC21-036-230 TXV 36000 16 12.5 CX35-36A 8249778XC21-036-230 TXV 36000 18 13.5 CX35-36B CBWMV-36B-070 8249779XC21-036-230 TXV 36000 18 13.5 CX35-36B EL180UH070E36B 8249780XC21-036-230 TXV 36000 18 13.5 CX35-36B EL180UH090E48B 8249781XC21-036-230 TXV 36000 18 13 CX35-36B EL195UH045XE36B 8249782XC21-036-230 TXV 36000 18 13 CX35-36B EL195UH070XE36B 8249783XC21-036-230 TXV 36000 18 13 CX35-36B EL296UH045XE36B 8249785XC21-036-230 TXV 36000 18 13.5 CX35-36B EL296UH045XV36B 8249784XC21-036-230 TXV 36000 18 13 CX35-36B EL296UH070XE36B 8249787XC21-036-230 TXV 36000 18 13.5 CX35-36B EL296UH070XV36B 8249786XC21-036-230 TXV 36000 19 13.5 CX35-36B SL280UH090V36B 8249788XC21-036-230 TXV 36000 18 13.5 CX35-36B SL280UH090V48B 8249789XC21-036-230 TXV 36000 18 13.5 CX35-36B SL280UH090XV48B 8249790XC21-036-230 TXV 36000 18 13.5 CX35-36B SLO185B124/141V60 8249791XC21-036-230 TXV 36000 19 13.5 CX35-36B SLO185UF124/141V60 8249792XC21-036-230 TXV 36000 18 13.5 CX35-36B SLP98UH070XV36B 8249793XC21-036-230 TXV 36000 16 12.5 CX35-36B 8249794XC21-036-230 TXV 36000 18 13.5 CX35-48B EL180UH070E36B 8249795XC21-036-230 TXV 36000 18 13.5 CX35-48B EL180UH090E48B 8249796XC21-036-230 TXV 36000 18 13 CX35-48B EL195UH045XE36B 8249797XC21-036-230 TXV 36000 18 13 CX35-48B EL195UH070XE36B 8249798XC21-036-230 TXV 36000 18 13 CX35-48B EL296UH045XE36B 8249800XC21-036-230 TXV 36000 18 13.5 CX35-48B EL296UH045XV36B 8249799XC21-036-230 TXV 36000 18 13 CX35-48B EL296UH070XE36B 8249802XC21-036-230 TXV 36000 18 13.5 CX35-48B EL296UH070XV36B 8249801XC21-036-230 TXV 36000 18 13.5 CX35-48B SL280UH090V48B 8249803XC21-036-230 TXV 36000 18 13.5 CX35-48B SL280UH090XV48B 8249804XC21-036-230 TXV 36000 18 13.5 CX35-48B SLP98UH070XV36B 8249805XC21-036-230 TXV 36000 16 12.5 CX35-48B 8249806XC21-036-230 TXV 36000 18 13.5 CX35-48C CBWMV-36C-090 8249807XC21-036-230 TXV 36000 18 13.5 CX35-48C EL195UH090XE48C 8249808XC21-036-230 TXV 36000 18 13.5 CX35-48C EL296UH090XE48C 8249811XC21-036-230 TXV 36000 18 13.5 CX35-48C EL296UH090XV36C 8249809XC21-036-230 TXV 36000 19 14 CX35-48C EL296UH090XV48C 8249810XC21-036-230 TXV 36000 19 13.5 CX35-48C EL296UH090XV60C 8249812XC21-036-230 TXV 36000 19 14 CX35-48C EL296UH110XV48C 8249813XC21-036-230 TXV 36000 19 14 CX35-48C EL296UH110XV60C 8249814XC21-036-230 TXV 36000 19 14 CX35-48C SL280UH090V60C 8249815XC21-036-230 TXV 36000 19 14 CX35-48C SL280UH090XV60C 8249816XC21-036-230 TXV 36000 18 13.5 CX35-48C SL280UH110V60C 8249817XC21-036-230 TXV 36000 18 13.5 CX35-48C SL280UH110XV60C 8249818XC21-036-230 TXV 36000 18 14 CX35-48C SLO185B124/141V60 8249819XC21-036-230 TXV 36000 18 13.5 CX35-48C SLO185UF124/141V60 8249820XC21-036-230 TXV 36000 18 13.5 CX35-48C SLP98UH090XV36C 8249821NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 31

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-036-230 TXV 36000 18 14 CX35-48C SLP98UH090XV48C 8249822XC21-036-230 TXV 36000 19 13.5 CX35-48C SLP98UH090XV60C 8249823XC21-036-230 TXV 36000 19 14 CX35-48C SLP98UH110XV60C 8249824XC21-036-230 TXV 36000 16 12.5 CX35-48C 8249825XC21-036-230 TXV 36000 18 13.5 CX35-50/60C EL195UH090XE48C 8249826XC21-036-230 TXV 36000 18 13.5 CX35-50/60C EL296UH090XE48C 8249829XC21-036-230 TXV 36000 18 13.5 CX35-50/60C EL296UH090XV36C 8249827XC21-036-230 TXV 36000 19 13.5 CX35-50/60C EL296UH090XV48C 8249828XC21-036-230 TXV 36000 19 13.5 CX35-50/60C EL296UH090XV60C 8249830XC21-036-230 TXV 36000 19 13.5 CX35-50/60C EL296UH110XV48C 8249831XC21-036-230 TXV 36000 18 13.5 CX35-50/60C SLO185B124/141V60 8249832XC21-036-230 TXV 36000 18 13.5 CX35-50/60C SLO185UF124/141V60 8249833XC21-036-230 TXV 36000 18 13.5 CX35-50/60C SLP98UH090XV36C 8249834XC21-036-230 TXV 36000 18 13.5 CX35-50/60C SLP98UH090XV48C 8249835XC21-036-230 TXV 36000 19 13.5 CX35-50/60C SLP98UH090XV60C 8249836XC21-036-230 TXV 36000 16 12.5 CX35-50/60C 8249837XC21-036-230 TXV 36000 19 14 CX35-60C SLO185B124/141V60 8249838XC21-036-230 TXV 36000 19 13.5 CX35-60C SLO185UF124/141V60 8249839XC21-036-230 TXV 36000 16 13 CX35-60C 8249840XC21-036-230 TXV 37000 19.2 14 CX38-49C SL280UH090V60C 10560067XC21-048-230 TXV 48000 17 12.5 C35-48B SL280UH090V48B 8251476XC21-048-230 TXV 48000 17 12.5 C35-48B SL280UH090XV48B 8251477XC21-048-230 TXV 48000 16 12 C35-48B 8251478XC21-048-230 TXV 48000 17 12.5 C35-48C EL180UH090E60C 8251479XC21-048-230 TXV 48000 17 13 C35-48C EL180UH110E60C 8251480XC21-048-230 TXV 48000 17 12.5 C35-48C EL195UH090XE48C 8251481XC21-048-230 TXV 48000 17 12.5 C35-48C EL195UH110XE60C 8251482XC21-048-230 TXV 48000 17 12.5 C35-48C EL296UH090XE48C 8251485XC21-048-230 TXV 48000 17 12.5 C35-48C EL296UH090XV48C 8251483XC21-048-230 TXV 48000 17 12.5 C35-48C EL296UH090XV60C 8251484XC21-048-230 TXV 48000 17 12.5 C35-48C EL296UH110XE60C 8251488XC21-048-230 TXV 48000 17 12.5 C35-48C EL296UH110XV48C 8251486XC21-048-230 TXV 48000 17 12.5 C35-48C EL296UH110XV60C 8251487XC21-048-230 TXV 48000 17 13 C35-48C SL280UH090V60C 8251489XC21-048-230 TXV 48000 17 13 C35-48C SL280UH090XV60C 8251490XC21-048-230 TXV 48000 17 13 C35-48C SL280UH110V60C 8251491XC21-048-230 TXV 48000 17 13 C35-48C SL280UH110XV60C 8251492XC21-048-230 TXV 48000 17 12.5 C35-48C SLP98UH090XV48C 8251493XC21-048-230 TXV 48000 17 12.5 C35-48C SLP98UH090XV60C 8251494XC21-048-230 TXV 48000 17 12.5 C35-48C SLP98UH110XV60C 8251495XC21-048-230 TXV 48000 16 12 C35-48C 8251496XC21-048-230 TXV 48000 17 13 C35-49C EL180UH090E60C 8251497XC21-048-230 TXV 48000 17 13 C35-49C EL180UH110E60C 8251498XC21-048-230 TXV 48000 17 12.5 C35-49C EL195UH090XE48C 8251499XC21-048-230 TXV 48000 17 12.5 C35-49C EL195UH110XE60C 8251500XC21-048-230 TXV 48000 17 12.5 C35-49C EL296UH090XE48C 8251503XC21-048-230 TXV 48000 17 13 C35-49C EL296UH090XV48C 8251501XC21-048-230 TXV 48000 17 13 C35-49C EL296UH090XV60C 8251502NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 48000 17 12.5 C35-49C EL296UH110XE60C 8251506XC21-048-230 TXV 48000 17 13 C35-49C EL296UH110XV48C 8251504XC21-048-230 TXV 48000 17 13 C35-49C EL296UH110XV60C 8251505XC21-048-230 TXV 48000 17 13 C35-49C SL280UH090V60C 8251507XC21-048-230 TXV 48000 17 13 C35-49C SL280UH090XV60C 8251508XC21-048-230 TXV 48000 17 13 C35-49C SL280UH110V60C 8251509XC21-048-230 TXV 48000 17 13 C35-49C SL280UH110XV60C 8251510XC21-048-230 TXV 48000 17 13 C35-49C SLP98UH090XV48C 8251511XC21-048-230 TXV 48000 17 13 C35-49C SLP98UH090XV60C 8251512XC21-048-230 TXV 48000 17 13 C35-49C SLP98UH110XV60C 8251513XC21-048-230 TXV 47500 15.7 12 C35-49C 8251514XC21-048-230 TXV 48000 17 12.5 C35-50/60C CBWMV-60C-100 8251515XC21-048-230 TXV 48000 17 12.5 C35-50/60C CBWMV-60C-120 8251516XC21-048-230 TXV 48000 17 12.5 C35-50/60C EL180UH090E60C 8251517XC21-048-230 TXV 47000 17 12.5 C35-50/60C EL180UH110E60C 8251518XC21-048-230 TXV 48000 16.5 12.5 C35-50/60C EL195UH090XE48C 8251519XC21-048-230 TXV 48000 17 12.5 C35-50/60C EL195UH110XE60C 8251520XC21-048-230 TXV 48000 16.5 12.5 C35-50/60C EL296UH090XE48C 8251522XC21-048-230 TXV 47500 17 12.5 C35-50/60C EL296UH090XV48C 8251523XC21-048-230 TXV 47500 17 12.5 C35-50/60C EL296UH090XV60C 8251521XC21-048-230 TXV 48000 17 12.5 C35-50/60C EL296UH110XE60C 8251526XC21-048-230 TXV 47500 17 12.5 C35-50/60C EL296UH110XV48C 8251524XC21-048-230 TXV 47500 17 12.5 C35-50/60C EL296UH110XV60C 8251525XC21-048-230 TXV 47500 17 12.5 C35-50/60C SL280UH090V60C 8251527XC21-048-230 TXV 47500 17 12.5 C35-50/60C SL280UH090XV60C 8251528XC21-048-230 TXV 47500 17 12.5 C35-50/60C SL280UH110V60C 8251529XC21-048-230 TXV 47500 17 12.5 C35-50/60C SL280UH110XV60C 8251530XC21-048-230 TXV 47500 17 12.5 C35-50/60C SLO185B124/141V60 8251531XC21-048-230 TXV 47500 16 12.5 C35-50/60C SLO185UF124/141V60 8251532XC21-048-230 TXV 47500 17 12.5 C35-50/60C SLP98UH090XV48C 8251533XC21-048-230 TXV 47500 17 12.5 C35-50/60C SLP98UH090XV60C 8251534XC21-048-230 TXV 48000 17 12.5 C35-50/60C SLP98UH110XV60C 8251535XC21-048-230 TXV 48000 15.7 12 C35-50/60C 8251536XC21-048-230 TXV 48000 18 13 C35-60C CBWMV-60C-100 8251537XC21-048-230 TXV 48000 18 13 C35-60C CBWMV-60C-120 8251538XC21-048-230 TXV 48000 18 13 C35-60C EL180UH090E60C 8251539XC21-048-230 TXV 48000 17 13.5 C35-60C EL180UH110E60C 8251540XC21-048-230 TXV 48000 17 13 C35-60C EL195UH090XE48C 8251541XC21-048-230 TXV 48000 17 13 C35-60C EL195UH110XE60C 8251542XC21-048-230 TXV 48000 17 13 C35-60C EL296UH090XE48C 8251545XC21-048-230 TXV 48000 18 13 C35-60C EL296UH090XV48C 8251543XC21-048-230 TXV 48000 18 13 C35-60C EL296UH090XV60C 8251544XC21-048-230 TXV 48000 17 13 C35-60C EL296UH110XE60C 8251548XC21-048-230 TXV 48000 18 13 C35-60C EL296UH110XV48C 8251546XC21-048-230 TXV 48000 18 13 C35-60C EL296UH110XV60C 8251547XC21-048-230 TXV 48000 18 13.5 C35-60C SL280UH090V60C 8251549XC21-048-230 TXV 48000 18 13.5 C35-60C SL280UH090XV60C 8251550XC21-048-230 TXV 48000 18 13.5 C35-60C SL280UH110V60C 8251551NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 33

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 48000 18 13.5 C35-60C SL280UH110XV60C 8251552XC21-048-230 TXV 48000 18 13.5 C35-60C SLO185B124/141V60 8251553XC21-048-230 TXV 48000 18 13.5 C35-60C SLO185UF124/141V60 8251554XC21-048-230 TXV 48000 18 13 C35-60C SLP98UH090XV48C 8251555XC21-048-230 TXV 48000 18 13 C35-60C SLP98UH090XV60C 8251556XC21-048-230 TXV 48000 18 13 C35-60C SLP98UH110XV60C 8251557XC21-048-230 TXV 48000 16 12.5 C35-60C 8251558XC21-048-230 TXV 48000 17 13 C35-60D EL296UH135XV60D 8251559XC21-048-230 TXV 48000 18 13 C35-60D SL280UH135V60D 8251560XC21-048-230 TXV 48000 17 13 C35-60D SLO185B124/141V60 8251561XC21-048-230 TXV 48000 17 13 C35-60D SLO185UF124/141V60 8251562XC21-048-230 TXV 48000 17 13 C35-60D SLP98UH135XV60D 8251563XC21-048-230 TXV 48000 16 12.5 C35-60D 8251564XC21-048-230 TXV 48000 18 13 CBA27UHE-048 10259513XC21-048-230 TXV 48000 18 13 CBA27UHE-060 10259514XC21-048-230 TXV 49500 18 13 CBX27UH-048 5991261XC21-048-230 TXV 48500 18 13 CBX27UH-060 5991262XC21-048-230 TXV 49000 17 12.5 CBX32M-048 5991263XC21-048-230 TXV 46500 17 12 CBX32MV-036 5991264XC21-048-230 TXV 49500 18 13 CBX32MV-048 5991265XC21-048-230 TXV 49500 18 13 CBX32MV-060 5991266XC21-048-230 TXV 49000 18 13 CBX32MV-068 5991317XC21-048-230 TXV 46500 17 12 CBX40UHV-036 5991318XC21-048-230 TXV 49500 18 13 CBX40UHV-048 5991319XC21-048-230 TXV 49500 18 13 CBX40UHV-060 5991320XC21-048-230 TXV 47000 16 12 CH23-41 EL180UH090E48B 5991406XC21-048-230 TXV 46500 16 12.5 CH23-41 EL180UH090E60C 5991421XC21-048-230 TXV 46500 16 12.5 CH23-41 EL180UH110E60C 5991399XC21-048-230 TXV 46500 16 12 CH23-41 EL195UH090XE48C 5991101XC21-048-230 TXV 46500 16 12 CH23-41 EL195UH110XE60C 5991141XC21-048-230 TXV 46500 16 12 CH23-41 EL296UH090XE48C 5991355XC21-048-230 TXV 47000 17 12.5 CH23-41 EL296UH090XV48C 5991013XC21-048-230 TXV 47000 17 12.5 CH23-41 EL296UH090XV60C 5991030XC21-048-230 TXV 46500 16 12 CH23-41 EL296UH110XE60C 5991373XC21-048-230 TXV 47000 17 12.5 CH23-41 EL296UH110XV48C 5991048XC21-048-230 TXV 47000 17 12.5 CH23-41 EL296UH110XV60C 5991070XC21-048-230 TXV 46500 15.5 11.7 CH23-41 5990977XC21-048-230 TXV 47000 16 12 CH23-51 EL180UH090E48B 5991407XC21-048-230 TXV 47000 16 12.5 CH23-51 EL180UH090E60C 5991422XC21-048-230 TXV 46500 16 12.5 CH23-51 EL180UH110E60C 5991400XC21-048-230 TXV 46500 16 12 CH23-51 EL195UH090XE48C 5991113XC21-048-230 TXV 47000 16 12.5 CH23-51 EL195UH110XE60C 5991142XC21-048-230 TXV 46500 16 12 CH23-51 EL296UH090XE48C 5991356XC21-048-230 TXV 47000 17 12.5 CH23-51 EL296UH090XV48C 5991014XC21-048-230 TXV 47000 17 12.5 CH23-51 EL296UH090XV60C 5991031XC21-048-230 TXV 47000 16 12.5 CH23-51 EL296UH110XE60C 5991374XC21-048-230 TXV 47000 17 12.5 CH23-51 EL296UH110XV48C 5991049XC21-048-230 TXV 47000 17 12.5 CH23-51 EL296UH110XV60C 5991071NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 34

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 47000 17 12.5 CH23-51 EL296UH135XV60D 5991306XC21-048-230 TXV 47500 17 12.5 CH23-51 SL280UH090V60C 5991175XC21-048-230 TXV 47500 17 12.5 CH23-51 SL280UH090XV60C 5991278XC21-048-230 TXV 47000 17 12.5 CH23-51 SL280UH110V60C 5991176XC21-048-230 TXV 47000 17 12.5 CH23-51 SL280UH110XV60C 5991294XC21-048-230 TXV 47500 17 12.5 CH23-51 SL280UH135V60D 5991177XC21-048-230 TXV 47000 17 12.5 CH23-51 SLP98UH090XV60C 5991178XC21-048-230 TXV 47000 17 12.5 CH23-51 SLP98UH110XV60C 5991190XC21-048-230 TXV 47000 17 12.5 CH23-51 SLP98UH135XV60D 5991191XC21-048-230 TXV 47000 15.5 12 CH23-51 5990978XC21-048-230 TXV 47500 17 12.5 CH23-65 EL180UH090E60C 5991423XC21-048-230 TXV 47000 17 12.5 CH23-65 EL180UH110E60C 5991401XC21-048-230 TXV 47500 16 12.5 CH23-65 EL195UH090XE48C 5991114XC21-048-230 TXV 47500 17 12.5 CH23-65 EL195UH110XE60C 5991143XC21-048-230 TXV 47500 16 12.5 CH23-65 EL296UH090XE48C 5991357XC21-048-230 TXV 48000 17 12.5 CH23-65 EL296UH090XV48C 5991015XC21-048-230 TXV 48000 17 12.5 CH23-65 EL296UH090XV60C 5991032XC21-048-230 TXV 47500 17 12.5 CH23-65 EL296UH110XE60C 5991375XC21-048-230 TXV 48000 17 13 CH23-65 EL296UH110XV48C 5991050XC21-048-230 TXV 48000 17 12.5 CH23-65 EL296UH110XV60C 5991072XC21-048-230 TXV 47500 17 12.5 CH23-65 EL296UH135XV60D 5991307XC21-048-230 TXV 48000 17 13 CH23-65 SL280UH090V60C 5991192XC21-048-230 TXV 48000 17 13 CH23-65 SL280UH090XV60C 5991279XC21-048-230 TXV 48000 17 13 CH23-65 SL280UH110V60C 5991193XC21-048-230 TXV 48000 17 13 CH23-65 SL280UH110XV60C 5991295XC21-048-230 TXV 48000 17 13 CH23-65 SL280UH135V60D 5991194XC21-048-230 TXV 48000 17 12.5 CH23-65 SLP98UH090XV60C 5991195XC21-048-230 TXV 48000 17 12.5 CH23-65 SLP98UH110XV60C 5991196XC21-048-230 TXV 48000 17 12.5 CH23-65 SLP98UH135XV60D 5991197XC21-048-230 TXV 47500 15.7 12.2 CH23-65 5990979XC21-048-230 TXV 49500 17 13 CH23-68 EL180UH090E60C 5991424XC21-048-230 TXV 49000 17 13 CH23-68 EL180UH110E60C 5991402XC21-048-230 TXV 49500 17 13 CH23-68 EL195UH090XE48C 5991115XC21-048-230 TXV 49500 17 13 CH23-68 EL195UH110XE60C 5991144XC21-048-230 TXV 49500 17 13 CH23-68 EL296UH090XE48C 5991358XC21-048-230 TXV 50000 18 13 CH23-68 EL296UH090XV48C 5991016XC21-048-230 TXV 50000 18 13 CH23-68 EL296UH090XV60C 5991033XC21-048-230 TXV 49500 17 13 CH23-68 EL296UH110XE60C 5991376XC21-048-230 TXV 49500 18 13 CH23-68 EL296UH110XV48C 5991051XC21-048-230 TXV 49500 18 13 CH23-68 EL296UH110XV60C 5991073XC21-048-230 TXV 49500 18 13.5 CH23-68 EL296UH135XV60D 5991308XC21-048-230 TXV 50000 18 13.5 CH23-68 SL280UH090V60C 5991198XC21-048-230 TXV 50000 18 13.5 CH23-68 SL280UH090XV60C 5991280XC21-048-230 TXV 49500 18 13 CH23-68 SL280UH110V60C 5991199XC21-048-230 TXV 49500 18 13 CH23-68 SL280UH110XV60C 5991296XC21-048-230 TXV 50000 18 13.5 CH23-68 SL280UH135V60D 5991213XC21-048-230 TXV 50000 18 13 CH23-68 SLP98UH090XV60C 5991200XC21-048-230 TXV 49500 18 13 CH23-68 SLP98UH110XV60C 5991212NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 35

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 50000 18 13.5 CH23-68 SLP98UH135XV60D 5991214XC21-048-230 TXV 49500 16 12.5 CH23-68 5990980XC21-048-230 TXV 50000 17 13 CH33-43 SL280UH090V48B 5991253XC21-048-230 TXV 50000 17 13 CH33-43 SL280UH090XV48B 5991254XC21-048-230 TXV 48500 16 12.5 CH33-43 5990981XC21-048-230 TXV 48500 17 12.5 CH33-43B SLP98UH070XV36B 9100729XC21-048-230 TXV 48500 17 13 CH33-43C EL180UH090E60C 5991425XC21-048-230 TXV 48500 17 13 CH33-43C EL180UH110E60C 5991403XC21-048-230 TXV 48500 17 12.5 CH33-43C EL195UH090XE48C 5991116XC21-048-230 TXV 48500 17 13 CH33-43C EL195UH110XE60C 5991145XC21-048-230 TXV 48500 17 12.5 CH33-43C EL296UH090XE48C 5991359XC21-048-230 TXV 49000 17 12.5 CH33-43C EL296UH090XV48C 5991017XC21-048-230 TXV 49000 17 12.5 CH33-43C EL296UH090XV60C 5991034XC21-048-230 TXV 48500 17 13 CH33-43C EL296UH110XE60C 5991377XC21-048-230 TXV 49000 17 13 CH33-43C EL296UH110XV48C 5991052XC21-048-230 TXV 48500 17 12.5 CH33-43C EL296UH110XV60C 5991074XC21-048-230 TXV 48500 17 12.5 CH33-44/48 SL280UH090V48B 5991255XC21-048-230 TXV 48500 17 12.5 CH33-44/48 SL280UH090XV48B 5991267XC21-048-230 TXV 48500 17 12.5 CH33-48 EL296UH090XV48C 5991018XC21-048-230 TXV 48500 17 12.5 CH33-48 EL296UH090XV60C 5991035XC21-048-230 TXV 48500 17 12.5 CH33-48 EL296UH110XV60C 5991075XC21-048-230 TXV 48500 17 12.5 CH33-48 SL280UH090V60C 5991215XC21-048-230 TXV 48500 17 12.5 CH33-48 SL280UH090XV60C 5991281XC21-048-230 TXV 48500 17 12.5 CH33-48 SL280UH110V60C 5991216XC21-048-230 TXV 48500 17 12.5 CH33-48 SL280UH110XV60C 5991297XC21-048-230 TXV 48500 17 12.5 CH33-48 SLP98UH090XV48C 5991218XC21-048-230 TXV 48500 17 12.5 CH33-48 SLP98UH090XV60C 5991217XC21-048-230 TXV 48500 17 12.5 CH33-48 SLP98UH110XV60C 5991219XC21-048-230 TXV 48500 16 12.5 CH33-48 5990982XC21-048-230 TXV 47500 17 12.5 CH33-48C EL180UH090E60C 5991413XC21-048-230 TXV 48000 17 13 CH33-48C EL180UH110E60C 5991408XC21-048-230 TXV 48000 17 12.5 CH33-48C EL195UH090XE48C 5991117XC21-048-230 TXV 48500 17 13 CH33-48C EL195UH110XE60C 5991157XC21-048-230 TXV 48000 17 12.5 CH33-48C EL296UH090XE48C 5991360XC21-048-230 TXV 48500 17 13 CH33-48C EL296UH110XE60C 5991378XC21-048-230 TXV 48500 17 12.5 CH33-48C EL296UH110XV48C 5991053XC21-048-230 TXV 49500 18 13 CH33-49 CBWMV-60C-100 5991311XC21-048-230 TXV 49000 17 13 CH33-49 EL180UH090E60C 5991426XC21-048-230 TXV 49000 17 13 CH33-49 EL180UH110E60C 5991409XC21-048-230 TXV 49000 17 13 CH33-49 EL195UH090XE48C 5991118XC21-048-230 TXV 49000 17 13 CH33-49 EL195UH110XE60C 5991158XC21-048-230 TXV 49000 17 13 CH33-49 EL296UH090XE48C 5991361XC21-048-230 TXV 49500 17 13 CH33-49 EL296UH090XV48C 5991019XC21-048-230 TXV 49500 17 13 CH33-49 EL296UH090XV60C 5991036XC21-048-230 TXV 49000 17 13 CH33-49 EL296UH110XE60C 5991379XC21-048-230 TXV 49500 17 13 CH33-49 EL296UH110XV48C 5991054XC21-048-230 TXV 49500 17 13 CH33-49 EL296UH110XV60C 5991076XC21-048-230 TXV 49500 17 13 CH33-49 SL280UH090V60C 5991220NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 36

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 49500 17 13 CH33-49 SL280UH090XV60C 5991282XC21-048-230 TXV 49500 17 13 CH33-49 SL280UH110V60C 5991221XC21-048-230 TXV 49500 17 13 CH33-49 SL280UH110XV60C 5991298XC21-048-230 TXV 49500 17 13 CH33-49 SLP98UH090XV48C 5991234XC21-048-230 TXV 49500 17 13 CH33-49 SLP98UH090XV60C 5991222XC21-048-230 TXV 49500 17 13 CH33-49 SLP98UH110XV60C 5991235XC21-048-230 TXV 49500 16 12.5 CH33-49 5990983XC21-048-230 TXV 48000 17 12.5 CH33-50/60C EL180UH090E60C 5991417XC21-048-230 TXV 48500 17 13 CH33-50/60C EL180UH110E60C 5991410XC21-048-230 TXV 49000 17 13 CH33-50/60C EL195UH090XE48C 5991119XC21-048-230 TXV 49000 17 13 CH33-50/60C EL195UH110XE60C 5991159XC21-048-230 TXV 49000 17 13 CH33-50/60C EL296UH090XE48C 5991362XC21-048-230 TXV 49000 17 12.5 CH33-50/60C EL296UH090XV48C 5991020XC21-048-230 TXV 49000 17 12.5 CH33-50/60C EL296UH090XV60C 5991037XC21-048-230 TXV 49000 17 13 CH33-50/60C EL296UH110XE60C 5991380XC21-048-230 TXV 49000 17 13 CH33-50/60C EL296UH110XV48C 5991386XC21-048-230 TXV 49000 17 12.5 CH33-50/60C EL296UH110XV60C 5991077XC21-048-230 TXV 49500 17 13 CH33-50/60C SL280UH090V60C 5991236XC21-048-230 TXV 49500 17 13 CH33-50/60C SL280UH090XV60C 5991283XC21-048-230 TXV 49000 17 13 CH33-50/60C SL280UH110V60C 5991237XC21-048-230 TXV 49000 17 13 CH33-50/60C SL280UH110XV60C 5991299XC21-048-230 TXV 49000 17 12.5 CH33-50/60C SLP98UH090XV48C 5991239XC21-048-230 TXV 49000 17 12.5 CH33-50/60C SLP98UH090XV60C 5991238XC21-048-230 TXV 49500 17 13 CH33-50/60C SLP98UH110XV60C 5991240XC21-048-230 TXV 49000 16 12.5 CH33-50/60C 5990984XC21-048-230 TXV 48500 17 13 CH33-60D EL296UH135XV60D 5991309XC21-048-230 TXV 49000 17 13 CH33-60D SL280UH135V60D 5991241XC21-048-230 TXV 49000 17 13 CH33-60D SLP98UH135XV60D 5991242XC21-048-230 TXV 48500 16 12 CH33-60D 5990985XC21-048-230 TXV 48500 17 13 CH33-62D EL296UH135XV60D 5991310XC21-048-230 TXV 49000 17 13 CH33-62D SL280UH135V60D 5991243XC21-048-230 TXV 49000 17 13 CH33-62D SLP98UH135XV60D 5991244XC21-048-230 TXV 48500 16 12.5 CH33-62D 5990986XC21-048-230 TXV 48000 17 13 CH35-42B SL280UH090V48B 7164726XC21-048-230 TXV 48000 17 13 CH35-42B SL280UH090XV48B 7164727XC21-048-230 TXV 48000 16 12.5 CH35-42B 7164729XC21-048-230 TXV 48000 17 13 CH35-42C EL180UH090E60C 7164741XC21-048-230 TXV 48000 17 13 CH35-42C EL180UH110E60C 7164742XC21-048-230 TXV 48000 17 13 CH35-42C EL195UH090XE48C 7164731XC21-048-230 TXV 48000 17 13 CH35-42C EL195UH110XE60C 7164733XC21-048-230 TXV 48000 17 13 CH35-42C EL296UH090XE48C 7164732XC21-048-230 TXV 48000 17 12.5 CH35-42C EL296UH090XV48C 7164736XC21-048-230 TXV 48000 17 12.5 CH35-42C EL296UH090XV60C 7164737XC21-048-230 TXV 48000 17 13 CH35-42C EL296UH110XE60C 7164735XC21-048-230 TXV 48000 17 13 CH35-42C EL296UH110XV48C 7164738XC21-048-230 TXV 48000 17 12.5 CH35-42C EL296UH110XV60C 7164739XC21-048-230 TXV 48000 16 12.5 CH35-42C 7164730XC21-048-230 TXV 48000 17 12.5 CH35-48B SL280UH090V48B 7164743XC21-048-230 TXV 48000 17 12.5 CH35-48B SL280UH090XV48B 7164744NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 37

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 48000 16 12.5 CH35-48B 7164745XC21-048-230 TXV 48000 17 13 CH35-48C EL180UH090E60C 7164757XC21-048-230 TXV 48000 17 13 CH35-48C EL180UH110E60C 7164758XC21-048-230 TXV 48000 17 12.5 CH35-48C EL195UH090XE48C 7164748XC21-048-230 TXV 48000 17 13 CH35-48C EL195UH110XE60C 7164750XC21-048-230 TXV 48000 17 12.5 CH35-48C EL296UH090XE48C 7164749XC21-048-230 TXV 48000 17 12.5 CH35-48C EL296UH090XV48C 7164752XC21-048-230 TXV 48000 17 12.5 CH35-48C EL296UH090XV60C 7164753XC21-048-230 TXV 48000 17 13 CH35-48C EL296UH110XE60C 7164751XC21-048-230 TXV 48000 17 13 CH35-48C EL296UH110XV48C 7164754XC21-048-230 TXV 48000 17 12.5 CH35-48C EL296UH110XV60C 7164756XC21-048-230 TXV 48000 17 13 CH35-48C SL280UH090V60C 7164759XC21-048-230 TXV 48000 17 13 CH35-48C SL280UH090XV60C 7164761XC21-048-230 TXV 48000 17 13 CH35-48C SL280UH110V60C 7164764XC21-048-230 TXV 48000 17 13 CH35-48C SL280UH110XV60C 7164766XC21-048-230 TXV 48000 17 12.5 CH35-48C SLP98UH090XV48C 7164768XC21-048-230 TXV 48000 17 12.5 CH35-48C SLP98UH090XV60C 7164770XC21-048-230 TXV 48000 17 12.5 CH35-48C SLP98UH110XV60C 7164771XC21-048-230 TXV 48000 16 12.5 CH35-48C 7164746XC21-048-230 TXV 48000 18 13 CH35-51C CBWMV-60C-100 7164775XC21-048-230 TXV 48000 17 13 CH35-51C EL180UH090E60C 7164790XC21-048-230 TXV 48000 17 13 CH35-51C EL180UH110E60C 7164791XC21-048-230 TXV 48000 17 13 CH35-51C EL195UH090XE48C 7164777XC21-048-230 TXV 48000 17 13 CH35-51C EL195UH110XE60C 7164780XC21-048-230 TXV 48000 17 13 CH35-51C EL296UH090XE48C 7164778XC21-048-230 TXV 48000 17 13 CH35-51C EL296UH090XV48C 7164783XC21-048-230 TXV 48000 17 13 CH35-51C EL296UH090XV60C 7164784XC21-048-230 TXV 48000 17 13 CH35-51C EL296UH110XE60C 7164782XC21-048-230 TXV 48000 17 13 CH35-51C EL296UH110XV48C 7164786XC21-048-230 TXV 48000 17 13 CH35-51C EL296UH110XV60C 7164788XC21-048-230 TXV 48000 18 13 CH35-51C SL280UH090V60C 7164793XC21-048-230 TXV 48000 18 13 CH35-51C SL280UH090XV60C 7164795XC21-048-230 TXV 48000 17 13 CH35-51C SL280UH110V60C 7164797XC21-048-230 TXV 48000 17 13 CH35-51C SL280UH110XV60C 7164798XC21-048-230 TXV 48000 17 13 CH35-51C SLP98UH090XV48C 7164800XC21-048-230 TXV 48000 17 13 CH35-51C SLP98UH090XV60C 7164802XC21-048-230 TXV 48000 17 13 CH35-51C SLP98UH110XV60C 7164804XC21-048-230 TXV 48000 16 12.5 CH35-51C 7164773XC21-048-230 TXV 48000 17 13 CH35-60D EL296UH135XV60D 7164807XC21-048-230 TXV 48000 17 13 CH35-60D SL280UH135V60D 7164809XC21-048-230 TXV 48000 17 13 CH35-60D SLP98UH135XV60D 7164810XC21-048-230 TXV 48000 16 12.5 CH35-60D 7164806XC21-048-230 TXV 48000 17 13 CR33-48 EL180DF110E60C 5991387XC21-048-230 TXV 47000 16 12 CR33-48 EL195DF070XE48B 5991160XC21-048-230 TXV 47500 16 12.5 CR33-48 EL195DF090XE48C 5991161XC21-048-230 TXV 48500 17 13 CR33-48 EL195DF110XE60C 5991164XC21-048-230 TXV 47000 16 12 CR33-48 EL296DF070XE48B 5991381XC21-048-230 TXV 47500 16 12.5 CR33-48 EL296DF090XE48C 5991382NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 38

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 47500 17 12 CR33-48 EL296DF090XV60C 5991078XC21-048-230 TXV 48500 17 13 CR33-48 EL296DF110XE60C 5991385XC21-048-230 TXV 47500 16 12 CR33-48 SL280DF090V48B 9100728XC21-048-230 TXV 47500 15.7 12.2 CR33-48 5990960XC21-048-230 TXV 49000 18 13 CR33-50/60 EL180DF110E60C 5991388XC21-048-230 TXV 48500 17 12.5 CR33-50/60 EL195DF090XE48C 5991162XC21-048-230 TXV 48500 17 13 CR33-50/60 EL195DF110XE60C 5991163XC21-048-230 TXV 48500 17 12.5 CR33-50/60 EL296DF090XE48C 5991383XC21-048-230 TXV 49000 17 12.5 CR33-50/60 EL296DF090XV60C 5991079XC21-048-230 TXV 48500 17 13 CR33-50/60 EL296DF110XE60C 5991384XC21-048-230 TXV 49000 17 13 CR33-50/60 EL296DF110XV60C 5991316XC21-048-230 TXV 49000 18 13 CR33-50/60 SL280DF090V60C 5991256XC21-048-230 TXV 49000 18 13 CR33-50/60 SL280DF110V60C 5991257XC21-048-230 TXV 49000 17 12.5 CR33-50/60 SLP98DF090XV48C 5991259XC21-048-230 TXV 49000 17 12.5 CR33-50/60 SLP98DF090XV60C 5991258XC21-048-230 TXV 49000 17 13 CR33-50/60 SLP98DF110XV60C 5991260XC21-048-230 TXV 48500 16 12.5 CR33-50/60 5990961XC21-048-230 TXV 48500 16 12.5 CR33-60 5990976XC21-048-230 TXV 48000 17 12.5 CX35-48B EL180UH090E60C 8251565XC21-048-230 TXV 48000 17 12.5 CX35-48B SL280UH090V48B 8251566XC21-048-230 TXV 48000 17 12.5 CX35-48B SL280UH090XV48B 8251567XC21-048-230 TXV 48000 16 12 CX35-48B 8251568XC21-048-230 TXV 48000 17 12.5 CX35-48C CBWMV-60C-100 8251569XC21-048-230 TXV 48000 17 12.5 CX35-48C CBWMV-60C-120 8251570XC21-048-230 TXV 48000 17 12.5 CX35-48C EL180UH090E60C 8251571XC21-048-230 TXV 48000 17 13 CX35-48C EL180UH110E60C 8251572XC21-048-230 TXV 48000 17 12.5 CX35-48C EL195UH090XE48C 8251573XC21-048-230 TXV 48000 17 12.5 CX35-48C EL195UH110XE60C 8251574XC21-048-230 TXV 48000 17 12.5 CX35-48C EL296UH090XE48C 8251577XC21-048-230 TXV 48000 17 12.5 CX35-48C EL296UH090XV48C 8251575XC21-048-230 TXV 48000 17 12.5 CX35-48C EL296UH090XV60C 8251576XC21-048-230 TXV 48000 17 12.5 CX35-48C EL296UH110XE60C 8251580XC21-048-230 TXV 48000 17 12.5 CX35-48C EL296UH110XV48C 8251578XC21-048-230 TXV 48000 17 12.5 CX35-48C EL296UH110XV60C 8251579XC21-048-230 TXV 48000 17 12.5 CX35-48C SL280UH090V60C 8251581XC21-048-230 TXV 48000 17 12.5 CX35-48C SL280UH090XV60C 8251582XC21-048-230 TXV 48000 17 12.5 CX35-48C SL280UH110V60C 8251583XC21-048-230 TXV 48000 17 12.5 CX35-48C SL280UH110XV60C 8251584XC21-048-230 TXV 48000 17 12.5 CX35-48C SLP98UH090XV48C 8251585XC21-048-230 TXV 48000 17 12.5 CX35-48C SLP98UH090XV60C 8251586XC21-048-230 TXV 48000 17 12.5 CX35-48C SLP98UH110XV60C 8251587XC21-048-230 TXV 48000 16 12 CX35-48C 8251588XC21-048-230 TXV 48000 17 12.5 CX35-49C CBWMV-60C-100 8251589XC21-048-230 TXV 48000 17 12.5 CX35-49C CBWMV-60C-120 8251590XC21-048-230 TXV 48000 17 13 CX35-49C EL180UH090E60C 8251591XC21-048-230 TXV 48000 17 13 CX35-49C EL180UH110E60C 8251592XC21-048-230 TXV 48000 17 12.5 CX35-49C EL195UH090XE48C 8251593XC21-048-230 TXV 48000 17 12.5 CX35-49C EL195UH110XE60C 8251594NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 39

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 48000 17 12.5 CX35-49C EL296UH090XE48C 8251597XC21-048-230 TXV 48000 17 12.5 CX35-49C EL296UH090XV48C 8251595XC21-048-230 TXV 48000 17 12.5 CX35-49C EL296UH090XV60C 8251596XC21-048-230 TXV 48000 17 12.5 CX35-49C EL296UH110XE60C 8251600XC21-048-230 TXV 48000 17 13 CX35-49C EL296UH110XV48C 8251598XC21-048-230 TXV 48000 17 12.5 CX35-49C EL296UH110XV60C 8251599XC21-048-230 TXV 48000 17 13 CX35-49C SL280UH090V60C 8251601XC21-048-230 TXV 48000 17 13 CX35-49C SL280UH090XV60C 8251602XC21-048-230 TXV 48000 17 13 CX35-49C SL280UH110V60C 8251603XC21-048-230 TXV 48000 17 13 CX35-49C SL280UH110XV60C 8251604XC21-048-230 TXV 48000 17 12.5 CX35-49C SLP98UH090XV48C 8251605XC21-048-230 TXV 48000 17 12.5 CX35-49C SLP98UH090XV60C 8251606XC21-048-230 TXV 48000 17 12.5 CX35-49C SLP98UH110XV60C 8251607XC21-048-230 TXV 47500 15.7 12 CX35-49C 8251608XC21-048-230 TXV 48000 17 12.5 CX35-50/60C CBWMV-60C-100 8251609XC21-048-230 TXV 48000 17 12.5 CX35-50/60C CBWMV-60C-120 8251610XC21-048-230 TXV 48000 17 12.5 CX35-50/60C EL180UH090E60C 8251611XC21-048-230 TXV 47000 17 12.5 CX35-50/60C EL180UH110E60C 8251612XC21-048-230 TXV 48000 16.5 12.5 CX35-50/60C EL195UH090XE48C 8251613XC21-048-230 TXV 48000 17 12.5 CX35-50/60C EL195UH110XE60C 8251614XC21-048-230 TXV 48000 16.5 12.5 CX35-50/60C EL296UH090XE48C 8251616XC21-048-230 TXV 47500 17 12.5 CX35-50/60C EL296UH090XV48C 8251617XC21-048-230 TXV 48000 17 12.5 CX35-50/60C EL296UH090XV60C 8251615XC21-048-230 TXV 48000 17 12.5 CX35-50/60C EL296UH110XE60C 8251620XC21-048-230 TXV 47500 17 12.5 CX35-50/60C EL296UH110XV48C 8251618XC21-048-230 TXV 47500 17 12.5 CX35-50/60C EL296UH110XV60C 8251619XC21-048-230 TXV 47500 17 12.5 CX35-50/60C SL280UH090V60C 8251621XC21-048-230 TXV 47500 17 12.5 CX35-50/60C SL280UH090XV60C 8251622XC21-048-230 TXV 47500 17 12.5 CX35-50/60C SL280UH110V60C 8251623XC21-048-230 TXV 47500 17 12.5 CX35-50/60C SL280UH110XV60C 8251624XC21-048-230 TXV 47500 17 12.5 CX35-50/60C SLO185B124/141V60 8251625XC21-048-230 TXV 47500 16 12.5 CX35-50/60C SLO185UF124/141V60 8251626XC21-048-230 TXV 47500 17 12.5 CX35-50/60C SLP98UH090XV48C 8251627XC21-048-230 TXV 47500 17 12.5 CX35-50/60C SLP98UH090XV60C 8251628XC21-048-230 TXV 48000 17 12.5 CX35-50/60C SLP98UH110XV60C 8251629XC21-048-230 TXV 48000 15.7 12 CX35-50/60C 8251630XC21-048-230 TXV 48000 18 13 CX35-60C CBWMV-60C-100 8251631XC21-048-230 TXV 48000 18 13 CX35-60C CBWMV-60C-120 8251632XC21-048-230 TXV 48000 18 13 CX35-60C EL180UH090E60C 8251633XC21-048-230 TXV 48000 17 13.5 CX35-60C EL180UH110E60C 8251634XC21-048-230 TXV 48000 17 13 CX35-60C EL195UH090XE48C 8251635XC21-048-230 TXV 48000 17 13 CX35-60C EL195UH110XE60C 8251636XC21-048-230 TXV 48000 17 13 CX35-60C EL296UH090XE48C 8251639XC21-048-230 TXV 48000 18 13 CX35-60C EL296UH090XV48C 8251637XC21-048-230 TXV 48000 18 13 CX35-60C EL296UH090XV60C 8251638XC21-048-230 TXV 48000 17 13 CX35-60C EL296UH110XE60C 8251642XC21-048-230 TXV 48000 18 13 CX35-60C EL296UH110XV48C 8251640XC21-048-230 TXV 48000 18 13 CX35-60C EL296UH110XV60C 8251641NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 40

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-048-230 TXV 48000 18 13.5 CX35-60C SL280UH090V60C 8251643XC21-048-230 TXV 48000 18 13.5 CX35-60C SL280UH090XV60C 8251644XC21-048-230 TXV 48000 18 13.5 CX35-60C SL280UH110V60C 8251645XC21-048-230 TXV 48000 18 13.5 CX35-60C SL280UH110XV60C 8251646XC21-048-230 TXV 48000 18 13.5 CX35-60C SLO185B124/141V60 8251647XC21-048-230 TXV 48000 18 13.5 CX35-60C SLO185UF124/141V60 8251648XC21-048-230 TXV 48000 18 13 CX35-60C SLP98UH090XV48C 8251649XC21-048-230 TXV 48000 18 13 CX35-60C SLP98UH090XV60C 8251650XC21-048-230 TXV 48000 18 13 CX35-60C SLP98UH110XV60C 8251651XC21-048-230 TXV 48000 16 12.5 CX35-60C 8251652XC21-048-230 TXV 48000 17 13 CX35-60D EL296UH135XV60D 8251653XC21-048-230 TXV 48000 18 13 CX35-60D SL280UH135V60D 8251654XC21-048-230 TXV 48000 17 13 CX35-60D SLO185B124/141V60 8251655XC21-048-230 TXV 48000 17 13 CX35-60D SLO185UF124/141V60 8251656XC21-048-230 TXV 48000 17 13 CX35-60D SLP98UH135XV60D 8251657XC21-048-230 TXV 48000 16 12.5 CX35-60D 8251658XC21-048-230 TXV 49000 17.7 13 CX38-49C SL280UH090V60C 10560153XC21-060-230 TXV 56000 15 11.7 C35-48C CBWMV-60C-100 8248758XC21-060-230 TXV 56000 15 11.7 C35-48C CBWMV-60C-120 8248759XC21-060-230 TXV 55500 15 11.7 C35-48C EL180UH090E60C 8248760XC21-060-230 TXV 55500 15 11.7 C35-48C EL180UH110E60C 8248761XC21-060-230 TXV 55500 15 11.7 C35-48C EL180UH110XE60C 8248762XC21-060-230 TXV 55500 14.5 11.7 C35-48C EL195UH110XE60C 8248763XC21-060-230 TXV 55000 15 11.7 C35-48C EL296UH090XV60C 8248764XC21-060-230 TXV 55500 15 11.7 C35-48C EL296UH110XE60C 8248765XC21-060-230 TXV 56000 15 11.7 C35-48C SL280UH090V60C 8248767XC21-060-230 TXV 56000 15 11.7 C35-48C SL280UH090XV60C 8248768XC21-060-230 TXV 55500 15 11.7 C35-48C SL280UH110V60C 8248769XC21-060-230 TXV 55500 15 11.7 C35-48C SL280UH110XV60C 8249843XC21-060-230 TXV 55000 15 11.7 C35-48C SLP98UH090XV60C 8248770XC21-060-230 TXV 57000 15.5 11.7 C35-49C CBWMV-60C-100 8248773XC21-060-230 TXV 57000 15 11.7 C35-49C CBWMV-60C-120 8248774XC21-060-230 TXV 56500 15 12 C35-49C EL180UH090E60C 8248775XC21-060-230 TXV 56500 15 12 C35-49C EL180UH110E60C 8248777XC21-060-230 TXV 56500 15 12 C35-49C EL180UH110XE60C 8248776XC21-060-230 TXV 55000 14.5 11.7 C35-49C EL195UH110XE60C 8248778XC21-060-230 TXV 56000 15 11.7 C35-49C EL296UH090XV60C 8248779XC21-060-230 TXV 56500 15 11.7 C35-49C EL296UH110XE60C 8248780XC21-060-230 TXV 57000 15 11.7 C35-49C EL296UH110XV60C 8248781XC21-060-230 TXV 57500 15.5 12 C35-49C SL280UH090V60C 8248782XC21-060-230 TXV 57500 15.5 12 C35-49C SL280UH090XV60C 8248783XC21-060-230 TXV 56500 15 12 C35-49C SL280UH110V60C 8248784XC21-060-230 TXV 56500 15 12 C35-49C SL280UH110XV60C 8248785XC21-060-230 TXV 56000 15 11.7 C35-49C SLP98UH090XV60C 8248786XC21-060-230 TXV 57000 15 11.7 C35-49C SLP98UH110XV60C 8248787XC21-060-230 TXV 57000 14.5 11.7 C35-49C 8248788XC21-060-230 TXV 55000 15 11.7 C35-50/60C EL180UH090E60C 8248790XC21-060-230 TXV 55000 15 11.7 C35-50/60C EL180UH110E60C 8248791NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 41

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-060-230 TXV 55000 15 11.7 C35-50/60C EL180UH110XE60C 8248792XC21-060-230 TXV 55500 14.5 11.7 C35-50/60C EL195UH110XE60C 8248793XC21-060-230 TXV 55500 15 11.7 C35-50/60C EL296UH110XE60C 8248795XC21-060-230 TXV 55000 14.5 11.7 C35-50/60C EL296UH110XV60C 8248796XC21-060-230 TXV 55000 15 11.7 C35-50/60C SL280UH090V60C 8248797XC21-060-230 TXV 55000 15 11.7 C35-50/60C SL280UH090XV60C 8248798XC21-060-230 TXV 55000 14.5 11.7 C35-50/60C SL280UH110V60C 8248799XC21-060-230 TXV 55000 14.5 11.7 C35-50/60C SL280UH110XV60C 8248800XC21-060-230 TXV 55000 14.5 11.7 C35-50/60C SLP98UH110XV60C 8248802XC21-060-230 TXV 58500 16 12 C35-60C CBWMV-60C-100 8248804XC21-060-230 TXV 58000 15 11.7 C35-60C CBWMV-60C-120 8248805XC21-060-230 TXV 58000 15.5 12 C35-60C EL180UH090E60C 8248806XC21-060-230 TXV 58000 15.5 12 C35-60C EL180UH110E60C 8248809XC21-060-230 TXV 58000 15.5 12.2 C35-60C EL180UH110XE60C 8248808XC21-060-230 TXV 57500 15.5 12 C35-60C EL195UH110XE60C 8248810XC21-060-230 TXV 58000 15.5 12.2 C35-60C EL296UH090XV60C 8248811XC21-060-230 TXV 58500 15.5 12 C35-60C EL296UH110XE60C 8248812XC21-060-230 TXV 58000 15.2 12.2 C35-60C EL296UH110XV60C 8248807XC21-060-230 TXV 58500 16 12 C35-60C SL280UH090V60C 8248813XC21-060-230 TXV 58000 15.5 12.2 C35-60C SL280UH090XV60C 8248814XC21-060-230 TXV 58000 15.5 12 C35-60C SL280UH110V60C 8248815XC21-060-230 TXV 57500 15.5 12 C35-60C SL280UH110XV60C 8248816XC21-060-230 TXV 58000 15.5 12 C35-60C SLP98UH090XV60C 8248817XC21-060-230 TXV 58500 14.5 12 C35-60C SLP98UH110XV60C 8248818XC21-060-230 TXV 57500 15.5 12 C35-60C 8248819XC21-060-230 TXV 57500 15 11.7 C35-60D EL195UH135XE60D 8248821XC21-060-230 TXV 58000 15.5 12 C35-60D EL296UH135XE60D 8248822XC21-060-230 TXV 57500 16 12 C35-60D EL296UH135XV60D 8248823XC21-060-230 TXV 58000 15.5 11.7 C35-60D SL280UH135V60D 8248824XC21-060-230 TXV 58000 15.5 11.7 C35-60D SLO185B124/141V60 8248825XC21-060-230 TXV 58000 15.5 12 C35-60D SLO185UF124/141V60 8248826XC21-060-230 TXV 56500 14 11.7 C35-60D SLP98UH135XV60D 8248827XC21-060-230 TXV 56000 15 11.7 C35-60D 8248828XC21-060-230 TXV 56500 15.5 12 CBA27UHE-060 10259515XC21-060-230 TXV 56500 15.5 12 CBX27UH-060 6332803XC21-060-230 TXV 57500 14.5 12 CBX32M-060 6332804XC21-060-230 TXV 57000 16 12 CBX32MV-048 6332805XC21-060-230 TXV 57500 16 12 CBX32MV-060 6332806XC21-060-230 TXV 58000 16 12 CBX32MV-068 6332807XC21-060-230 TXV 56500 15.5 11.7 CBX40UHV-048 6332808XC21-060-230 TXV 57000 15.5 11.7 CBX40UHV-060 6332809XC21-060-230 TXV 55000 15 11.7 CH23-65 EL180UH090E60C 6332938XC21-060-230 TXV 56000 15.2 11.7 CH23-65 EL180UH110E60C 6332980XC21-060-230 TXV 55000 15 11.7 CH23-65 EL180UH110XE60C 6333583XC21-060-230 TXV 55000 15 11.7 CH23-65 EL180UH135E60D 6333588XC21-060-230 TXV 55000 14.5 11.7 CH23-65 EL195UH110XE60C 6332821XC21-060-230 TXV 55000 14.5 11.7 CH23-65 EL296UH110XE60C 6332823XC21-060-230 TXV 55500 15 11.7 CH23-65 EL296UH135XV60D 9150362NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 42

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-060-230 TXV 55500 15 11.7 CH23-65 SL280UH090V60C 6332831XC21-060-230 TXV 55500 15 11.7 CH23-65 SL280UH090XV60C 6332832XC21-060-230 TXV 55000 15 11.7 CH23-65 SL280UH110V60C 6332833XC21-060-230 TXV 55000 15 11.7 CH23-65 SL280UH110XV60C 6332834XC21-060-230 TXV 55500 15 11.7 CH23-65 SL280UH135V60D 6332835XC21-060-230 TXV 54500 15 11.7 CH23-65 SLP98UH090XV60C 6332836XC21-060-230 TXV 57500 15.5 12.2 CH23-68 EL180UH090E60C 6332939XC21-060-230 TXV 57500 15.5 12.2 CH23-68 EL180UH110E60C 6333573XC21-060-230 TXV 57500 15.5 12.2 CH23-68 EL180UH110XE60C 6333584XC21-060-230 TXV 60500 16 12 CH23-68 EL180UH135E60D 6332981XC21-060-230 TXV 57500 15.5 12 CH23-68 EL195UH110XE60C 6332840XC21-060-230 TXV 58000 15 12 CH23-68 EL195UH135XE60D 6332841XC21-060-230 TXV 57000 15.5 12.2 CH23-68 EL296UH090XV60C 6332844XC21-060-230 TXV 57500 15.5 12 CH23-68 EL296UH110XE60C 6332842XC21-060-230 TXV 58000 15.5 12.2 CH23-68 EL296UH110XV60C 6332845XC21-060-230 TXV 58000 15 12 CH23-68 EL296UH135XE60D 6332843XC21-060-230 TXV 58500 15.5 12.2 CH23-68 EL296UH135XV60D 6332846XC21-060-230 TXV 58500 16 12 CH23-68 SL280UH090V60C 6332851XC21-060-230 TXV 58500 16 12 CH23-68 SL280UH090XV60C 6332852XC21-060-230 TXV 57500 15.5 12.2 CH23-68 SL280UH110V60C 6332853XC21-060-230 TXV 57500 15.5 12.2 CH23-68 SL280UH110XV60C 6332854XC21-060-230 TXV 58500 16 12 CH23-68 SL280UH135V60D 6332855XC21-060-230 TXV 58000 15.5 11.7 CH23-68 SLP98UH090XV60C 6332856XC21-060-230 TXV 58000 15.5 12.2 CH23-68 SLP98UH110XV60C 6332857XC21-060-230 TXV 58500 16 12 CH23-68 SLP98UH135XV60D 6332858XC21-060-230 TXV 58000 14.5 12 CH23-68 6332839XC21-060-230 TXV 57500 15.5 12.2 CH33-49 EL180UH090E60C 6332940XC21-060-230 TXV 59000 15.2 11.7 CH33-49 EL180UH110E60C 6332982XC21-060-230 TXV 57000 15.5 12 CH33-49 EL180UH110XE60C 6333585XC21-060-230 TXV 57000 15.5 12 CH33-49 EL195UH110XE60C 6332860XC21-060-230 TXV 56500 15.5 11.7 CH33-49 EL296UH090XV60C 6332862XC21-060-230 TXV 57000 15.5 12 CH33-49 EL296UH110XE60C 6332861XC21-060-230 TXV 57500 15.5 11.7 CH33-49 EL296UH110XV60C 6332863XC21-060-230 TXV 57500 15.5 12 CH33-49 SL280UH090V60C 6332867XC21-060-230 TXV 57500 15.5 12 CH33-49 SL280UH090XV60C 6332868XC21-060-230 TXV 57000 15.5 12 CH33-49 SL280UH110V60C 6332869XC21-060-230 TXV 57000 15.5 12 CH33-49 SL280UH110XV60C 6332870XC21-060-230 TXV 56500 15.5 11.7 CH33-49 SLP98UH090XV60C 6332871XC21-060-230 TXV 57500 15.5 12 CH33-49 SLP98UH110XV60C 6332872XC21-060-230 TXV 56500 14.5 11.7 CH33-49 6332859XC21-060-230 TXV 57500 15.5 12.2 CH33-50/60C EL180UH090E60C 6332941XC21-060-230 TXV 58500 15.2 11.7 CH33-50/60C EL180UH110E60C 6332983XC21-060-230 TXV 57000 15.5 12 CH33-50/60C EL180UH110XE60C 6333586XC21-060-230 TXV 57000 15.5 12 CH33-50/60C EL195UH110XE60C 6332874XC21-060-230 TXV 56500 15 11.7 CH33-50/60C EL296UH090XV60C 6332876XC21-060-230 TXV 57000 15.5 12 CH33-50/60C EL296UH110XE60C 6332875XC21-060-230 TXV 56000 15 11.7 CH33-50/60C EL296UH110XV60C 6332877XC21-060-230 TXV 57000 15.5 12 CH33-50/60C SL280UH090V60C 6332881NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 43

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-060-230 TXV 57000 15.5 12 CH33-50/60C SL280UH090XV60C 6332882XC21-060-230 TXV 56500 15 11.7 CH33-50/60C SL280UH110V60C 6332883XC21-060-230 TXV 56500 15 11.7 CH33-50/60C SL280UH110XV60C 6332884XC21-060-230 TXV 56500 15 11.7 CH33-50/60C SLP98UH090XV60C 6332885XC21-060-230 TXV 56000 15 11.7 CH33-50/60C SLP98UH110XV60C 6332886XC21-060-230 TXV 56000 14 11.7 CH33-50/60C 6332873XC21-060-230 TXV 59000 15.7 12 CH33-60D EL180UH135E60D 6332968XC21-060-230 TXV 57000 15 11.7 CH33-60D EL195UH135XE60D 6332888XC21-060-230 TXV 57000 15 11.7 CH33-60D EL296UH135XE60D 6332889XC21-060-230 TXV 57000 15.5 12 CH33-60D EL296UH135XV60D 6332890XC21-060-230 TXV 56500 14 11.7 CH33-60D SL280UH135V60D 6332887XC21-060-230 TXV 57000 15.5 11.7 CH33-60D SLP98UH135XV60D 6332892XC21-060-230 TXV 60000 15.7 12.2 CH33-62D EL180UH135E60D 6332969XC21-060-230 TXV 57000 15 11.7 CH33-62D EL195UH135XE60D 6332894XC21-060-230 TXV 57000 15 11.7 CH33-62D EL296UH135XE60D 6332895XC21-060-230 TXV 57500 15.5 12 CH33-62D EL296UH135XV60D 6332896XC21-060-230 TXV 57000 15.5 12.2 CH33-62D SL280UH135V60D 6332898XC21-060-230 TXV 57500 15.5 12 CH33-62D SLP98UH135XV60D 6332899XC21-060-230 TXV 57000 14.5 11.7 CH33-62D 6332893XC21-060-230 TXV 57500 15.1 11.7 CH35-51C CBWMV-060C-120 7164641XC21-060-230 TXV 57500 15.5 12 CH35-51C EL180UH090E60C 7164646XC21-060-230 TXV 57500 15.5 12 CH35-51C EL180UH110E60C 7164647XC21-060-230 TXV 57500 15.5 12 CH35-51C EL180UH110XE60C 7164648XC21-060-230 TXV 57500 15.5 12 CH35-51C EL195UH110XE60C 7164642XC21-060-230 TXV 57500 15.5 12 CH35-51C EL296UH090XV60C 7164644XC21-060-230 TXV 57000 15.1 12 CH35-51C EL296UH110XE60C 7164643XC21-060-230 TXV 56500 15.1 12 CH35-51C EL296UH110XV60C 7164645XC21-060-230 TXV 57500 15.5 12 CH35-51C SL280UH090V60C 7164649XC21-060-230 TXV 57500 15.5 12 CH35-51C SL280UH090XV60C 7164650XC21-060-230 TXV 57500 15.5 12 CH35-51C SL280UH110V60C 7164651XC21-060-230 TXV 57500 15.5 12 CH35-51C SL280UH110XV60C 7164652XC21-060-230 TXV 57000 15.1 12 CH35-51C SLP98UH090XV60C 7164654XC21-060-230 TXV 56500 15.1 12 CH35-51C SLP98UH110XV60C 7164656XC21-060-230 TXV 56500 14.5 11.7 CH35-51C 7164640XC21-060-230 TXV 57500 15.1 12 CH35-60D EL180UH135E60D 7164662XC21-060-230 TXV 57000 15.1 11.7 CH35-60D EL195UH135XE60D 7164659XC21-060-230 TXV 57000 15.1 11.7 CH35-60D EL296UH135XE60D 7164660XC21-060-230 TXV 57500 15.5 12 CH35-60D EL296UH135XV60D 7164661XC21-060-230 TXV 57000 15.5 12 CH35-60D SL280UH135V60D 7164663XC21-060-230 TXV 58000 15.5 12 CH35-60D SLP98UH135XV60D 7164664XC21-060-230 TXV 57000 14.5 11.7 CH35-60D 7164658XC21-060-230 TXV 55000 15 11.7 CR33-50/60 EL296DF110XV60C 6332911XC21-060-230 TXV 56000 15.5 11.7 CR33-50/60 SL280DF090V60C 6332912XC21-060-230 TXV 56000 15.5 12 CR33-50/60 SL280DF110V60C 6332913XC21-060-230 TXV 55500 15 11.7 CR33-50/60 SLP98DF110XV60C 6332915XC21-060-230 TXV 56500 15 12 CR33-60 EL180DF110E60C 6333569XC21-060-230 TXV 55500 15 11.7 CR33-60 EL296DF110XV60C 6332918XC21-060-230 TXV 56000 15.5 11.7 CR33-60 SL280DF090V60C 6332921NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 44

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-060-230 TXV 56000 15.5 11.7 CR33-60 SL280DF110V60C 6332922XC21-060-230 TXV 55500 15 11.7 CR33-60 SLP98DF110XV60C 6332924XC21-060-230 TXV 56000 15 11.7 CX35-48C CBWMV-60C-100 8248829XC21-060-230 TXV 55500 15 11.7 CX35-48C CBWMV-60C-120 8248830XC21-060-230 TXV 55500 15 11.7 CX35-48C EL180UH090E60C 8248831XC21-060-230 TXV 55500 15 11.7 CX35-48C EL180UH110E60C 8248832XC21-060-230 TXV 55500 14.5 11.7 CX35-48C EL180UH110XE60C 8248833XC21-060-230 TXV 55000 15 11.7 CX35-48C EL195UH110XE60C 8248834XC21-060-230 TXV 55500 15 11.7 CX35-48C EL296UH090XV60C 8248835XC21-060-230 TXV 56000 15 11.7 CX35-48C EL296UH110XV60C 8248837XC21-060-230 TXV 56000 15 11.7 CX35-48C SL280UH090V60C 8248838XC21-060-230 TXV 55500 15 11.7 CX35-48C SL280UH090XV60C 8248839XC21-060-230 TXV 55500 15 11.7 CX35-48C SL280UH110V60C 8249844XC21-060-230 TXV 55000 15 11.7 CX35-48C SL280UH110XV60C 8248840XC21-060-230 TXV 56000 14 11.7 CX35-48C SLP98UH110XV60C 8248842XC21-060-230 TXV 57000 15.5 11.7 CX35-48C 8248843XC21-060-230 TXV 57000 15 11.7 CX35-49C CBWMV-60C-100 8248844XC21-060-230 TXV 56500 15 12 CX35-49C CBWMV-60C-120 8248845XC21-060-230 TXV 56500 15 12 CX35-49C EL180UH090E60C 8248846XC21-060-230 TXV 55000 14.5 11.7 CX35-49C EL180UH110E60C 8248848XC21-060-230 TXV 56500 15 12 CX35-49C EL180UH110XE60C 8248847XC21-060-230 TXV 56000 15 11.7 CX35-49C EL195UH110XE60C 8248849XC21-060-230 TXV 56500 15 11.7 CX35-49C EL296UH090XV60C 8248850XC21-060-230 TXV 57000 15 11.7 CX35-49C EL296UH110XE60C 8248851XC21-060-230 TXV 57500 15.5 12 CX35-49C EL296UH110XV60C 8248852XC21-060-230 TXV 57500 15.5 12 CX35-49C SL280UH090V60C 8248853XC21-060-230 TXV 56500 15 12 CX35-49C SL280UH090XV60C 8248854XC21-060-230 TXV 56500 15 12 CX35-49C SL280UH110V60C 8248855XC21-060-230 TXV 56000 15 11.7 CX35-49C SL280UH110XV60C 8248856XC21-060-230 TXV 57000 15 11.7 CX35-49C SLP98UH090XV60C 8248857XC21-060-230 TXV 57000 14.5 11.7 CX35-49C SLP98UH110XV60C 8248858XC21-060-230 TXV 55000 15 11.7 CX35-50/60C CBWMV-60C-100 8248860XC21-060-230 TXV 55000 15 11.7 CX35-50/60C EL180UH090E60C 8248861XC21-060-230 TXV 55000 15 11.7 CX35-50/60C EL180UH110E60C 8248862XC21-060-230 TXV 55500 14.5 11.7 CX35-50/60C EL180UH110XE60C 8248863XC21-060-230 TXV 55500 15 11.7 CX35-50/60C EL296UH090XV60C 8248865XC21-060-230 TXV 55000 14.5 11.7 CX35-50/60C EL296UH110XE60C 8248866XC21-060-230 TXV 55000 15 11.7 CX35-50/60C EL296UH110XV60C 8248867XC21-060-230 TXV 55000 15 11.7 CX35-50/60C SL280UH090V60C 8248868XC21-060-230 TXV 55000 14.5 11.7 CX35-50/60C SL280UH090XV60C 8248869XC21-060-230 TXV 55000 14.5 11.7 CX35-50/60C SL280UH110V60C 8248870XC21-060-230 TXV 55000 14.5 11.7 CX35-50/60C SLP98UH090XV60C 8248872XC21-060-230 TXV 58500 16 12 CX35-50/60C 8248874XC21-060-230 TXV 58000 15 11.7 CX35-60C CBWMV-60C-100 8248875XC21-060-230 TXV 58000 15.5 12 CX35-60C CBWMV-60C-120 8248876XC21-060-230 TXV 58000 15.2 12.2 CX35-60C EL180UH090E60C 8248877XC21-060-230 TXV 58000 15.5 12 CX35-60C EL180UH110E60C 8248879XC21-060-230 TXV 58000 15.5 12.2 CX35-60C EL180UH110XE60C 8248878NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

XC21 - 2 to 5 Ton Air Conditioner / Page 45

AHRI SYSTEM MATCHESNOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

XC21-060-230 TXV 57500 15.5 12 CX35-60C EL195UH110XE60C 8248880XC21-060-230 TXV 58000 15.5 12.2 CX35-60C EL296UH090XV60C 8248881XC21-060-230 TXV 58500 15.5 12 CX35-60C EL296UH110XE60C 8248882XC21-060-230 TXV 58500 16 12 CX35-60C EL296UH110XV60C 8248883XC21-060-230 TXV 58500 16 12 CX35-60C SL280UH090V60C 8248884XC21-060-230 TXV 58000 15.5 12 CX35-60C SL280UH110V60C 8248885XC21-060-230 TXV 58000 15.5 12 CX35-60C SL280UH110XV60C 8248886XC21-060-230 TXV 57500 15.5 12 CX35-60C SLP98UH090XV60C 8248887XC21-060-230 TXV 58000 15.5 12 CX35-60C SLP98UH110XV60C 8248888XC21-060-230 TXV 58500 14.5 11.7 CX35-60C 8248889XC21-060-230 TXV 57500 15 11.7 CX35-60D EL195UH135XE60D 8248891XC21-060-230 TXV 57500 15 11.7 CX35-60D EL296UH135XE60D 8248892XC21-060-230 TXV 58000 15.5 12 CX35-60D EL296UH135XV60D 8248893XC21-060-230 TXV 57500 16 12 CX35-60D SL280UH135V60D 8248894XC21-060-230 TXV 58000 15.5 11.7 CX35-60D SLO185B124/141V60 8248895XC21-060-230 TXV 58000 15.5 11.7 CX35-60D SLO185UF124/141V60 8248896XC21-060-230 TXV 58000 15.5 12 CX35-60D SLP98UH135XV60D 8248897XC21-060-230 TXV 56500 14 11.7 CX35-60D 8248898XC21-060-230 TXV 57500 16 12 CX38-62C SL280UH135V60D 10560270XC21-060-230 TXV 57500 16 12 CX38-62C SL280UH135V60D 10560270NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.Ratings are AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries, Inc.

Visit us at www.lennox.com

For the latest technical information, www.LennoxPROs.com

Contact us at 1-800-4-LENNOX

REVISIONS

Sections Description of Change

AHRI System Matches Updated

REVISIONS