SPECIFICATIONS1
Current consumption (Note 2)
Within % of sensing range at 20℃ over -25 to +70℃ temperature range+15-10
IncorporatedShort-circuit protection
0.15mm2 2-core cabtyre cable, 1m longCable
Orange LED (lights up when the output is ON)Operation indicator
20% or less of operation distance
2.5mm±20%
HysteresisIron sheet 15×15×t1mmStandard sensing object
Enclosure: PolyalylateMaterial
Sensing range variation
12g approx.Weight
1kHzMax. response frequency
IP67 (IEC)Protection-25 to +70℃, Storage: -30 to +80℃Ambient temperature
35 to 95% RH, Storage: 35 to 95% RHAmbient humidityTemperature characteristics
Within ±2% for ±10% fluctuation of the supply voltageVoltage characteristics
Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed
Output
Output operation
Non-contact DC 2-wire type・Load current: 3 to 70mA (Note 3)・Residual voltage: 3V or less (Note 4)
12 to 24V DC±10%0.8mA or less
Supply voltage
Max. operation distance (Note 1)0 to 1.8mmStable sensing range (Note 1)
Type
Model No.Item GL-8FU×10 GL-8FUB×10 GL-8FUI×10 GL-8FUIB×10Standard
GL-8HU×10 GL-8HUB×10StandardDifferent frequency
GL-8HUI×10 GL-8HUIB×10Different frequency
Front sensing Top sensing
Notes: 1)
2)3)4)
The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and / or supply voltage fluctuation.It is the leakage current when the output is in the OFF state.The maximum load current varies with the ambient temperature. Refer to ' I/O CIRCUIT DIAGRAM' for details.When the cable is extended, the residual voltage becomes larger according to the resistance of the cable.
3
Thank you very much for purchasing Panasinic products. Please read this Instruction Manual carefully and thorough-ly for the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference.
●
●
Never use this product as a sensing device for personnel protection.In case of using sensing devices for per-sonnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
WARNING
CAUTIONS2●
●●●
●
●
●
This product has been developed / produced for industrial use only.Make sure that the power supply is off while wiring.Take care that wrong wiring will damage the sensor.Verify that the supply voltage variation is within the rating.If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicini-ty of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.Do not run the wires together with high-voltage lines or power lines or put them in the same race-way. This can cause malfunction due to induction.
●
●
●
●
●
●
●
Extension up to total 50m is possible with a 0.3mm2, or more, cable.Do not use during the initial transient time (50ms) after the power supply is switched on.Take care that the product does not come in con-tact with oil, grease, organic solvents, such as, thinner etc., or strong acid, and alkaline.Make sure that stress by forcible bend or pulling is not applied to the sensor cable joint.Since the cable end is not waterproof, do not use the sensor in the application where water may seep in from the cable end.Make sure that the sensing end is not covered with metal dust, scrap or spatter. It will result in malfunction.Never disassemble or modify this sensor. It will get damaged.
MOUNTING4●・
MountingBe sure to mount using an M3 (length 12mm or more) truss head screw. The tightening torque should be 0.5N・m or less.(Do not use a flat head screw or a pan head screw.)
Front sensing type
If mounting using nut and washers.(Accessory with MS-GL8×10)
MS-GL8×10 (Optional)
M3(length 12mm or more) trusshead screw(Accessory with MS-GL8×10)
(Depth: 3mm or more)φ2.4mm hole
M3×0.5mm tapped hole(Depth: 8mm or more)or φ3.4mm thru-hole
11.5mm
(Depth: 3mm or more)φ2.4mm hole
If mounting using nut and washers.(Accessory with MS-GL8×10)
11.5mm
MS-GL8×10 (Optional)
M3(length 12mm or more) trusshead screw(Accessory with MS-GL8×10)
M3×0.5mm tapped hole(Depth: 8mm or more)or φ3.4mm thru-hole
Top sensing type
Between 'I' type and non 'I' type
Between 'I' type and non 'I' type
A 0mm (Note 2)
Between two 'I' types or two non 'I' types
Between two 'I' types or two non 'I' types
20mmB 15mm 40mm
0mm (Note 2) 25mm15mm 40mm
GL-8FU type GL-8HU type
Notes: 1)2)
'I' in the model No. specifies the different frequency type.Close mounting is possible for up to two sensors. When mounting three sensors or more, at an equal spacing, in a row, the minimum value of dimension 'A' should be as given below.GL-8FU type: 6mm, GL-8HU type: 8.5mm
Front sensing type Top sensing type
8mm Metal
Metal3mm
3mm10mm
Metal
Metal Metal
3mm3mm
Metal
3mm
3mm
A BA AB
●・
Mutual interference preventionWhen two or more sensors are installed in parallel or face to face, keep the minimum separation dis-tance specified below to avoid mutual interference.
●・
Sensing rangeThe sensing range is specified for the stand-ard sensing object. With a non-ferrous metal, the sensing range is ob-tained by multiplying with the correction coefficient specified on the right.
Note: The sensing range will also change if the sensing object is smaller than the standard sensing object or if it is plated.
Correction coefficientCorrectioncoefficientMetal
1Iron0.80approx.
Stainless steel (SUS304)
0.54approx.Brass
0.52approx.Aluminum
●・
Influence of surrounding metalWhen there is a metal near the sensor, keep the minimum separation distance specified below.
Top sensing type
Front sensing typeNote: The maximum load current varies depending on the am-
bient temperature.
Symbols...ZD
Tr
: Surge absorption zener diode: NPN output transistor
I/O CIRCUIT DIAGRAM3
Conditions for connected load(1) The load should not be actuated by the leakage current (0.8mA) in the OFF state.(2) The load should be actuated by (supply voltage -3V) in the ON state.(3) The current in the ON state should be between 3 to 70mA DC.
In case the current is less than 3mA, connect a bleeder resistance in parallel to the load so that a current of 3mA, or more, flows.
+
-12 to 24V DC±10%
Mai
n ci
rcui
t
TrZD
Internal circuit Users' circuit
(Brown) Output
(Blue) 0V
3V in theON state
3 to 70mA in the ON state(Note)0.8mA in the OFF state
Color code Bleeder resistance
Load
Load
70
35
-25 55 70
3
Ambient temperature (℃)
Max
. loa
d cu
rren
t(m
A)
INTENDED PRODUCTS FOR CE MARKING
5
● The models listed under ' SPECIFICATIONS' come with CE Marking.As for all other models, please contact our office.
1
GL-8FU□, GL-8HU□DC 2-wire Low Price & Compact
Inductive Proximity Sensor
INSTRUCTIONMANUAL
● Contact for CEPanasonic Marketing Europe GmbH Panasonic Testing CenterWinsbergring 15, 22525 Hamburg,Germany
MJEC-GL8U No.0054-93V
http://panasonic.net/id/pidsx/global
© Panasonic Industrial Devices SUNX Co., Ltd. 2016PRINTED IN JAPAN
Overseas Sales Division (Head Office) 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591For sales network, please visit our website.