dcmotor 1
Basics of a Electric Motor
![Page 2: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/2.jpg)
dcmotor 2
A Two Pole DC Motor
![Page 3: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/3.jpg)
dcmotor 3
A Four Pole DC Motor
![Page 4: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/4.jpg)
dcmotor 4
Operating Principle of a DC Machine
![Page 5: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/5.jpg)
dcmotor 5
FORE FINGER = MAGNETIC FIELD
900
900
900
MIDDLE FINGER= CURRENT
THU
MB =
MO
TION
FORCE = B IAl
Fleming’s Left Hand Rule Or Motor Rule
![Page 6: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/6.jpg)
dcmotor 6
FORE FINGER = MAGNETIC FIELD
900
900
900
MIDDLE FINGER = INDUCEDVOLTAGE
THUMB = M
OTION
VOLTAGE = B l u
Fleming’s Right Hand Rule OrGenerator Rule
![Page 7: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/7.jpg)
dcmotor 7
Action of a Commutator
![Page 8: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/8.jpg)
dcmotor 8
Armature of a DC Motor
![Page 9: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/9.jpg)
dcmotor 9
Generated Voltage in a DC Machine
![Page 10: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/10.jpg)
dcmotor 10
Armature Winding in a DC Machine
![Page 11: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/11.jpg)
dcmotor 11
Lap Winding of a DC Machine
• Used in high current low voltage circuits
•Number of parallel pathsequals number of brushes or poles
![Page 12: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/12.jpg)
dcmotor 12
Wave Winding of a DC Machine
• Used in high voltage low current circuits
•Number of parallel pathsalways equals 2
![Page 13: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/13.jpg)
dcmotor 13
Magnetic circuit of a 4 pole DC Machine
![Page 14: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/14.jpg)
dcmotor 14
Magnetic circuit of a 2 pole DC Machine
![Page 15: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/15.jpg)
dcmotor 15
Summary of a DC Machine
• Basically consists of
1. An electromagnetic or permanent magnetic structure called field which is static2. An Armature which rotates
• The Field produces a magnetic medium• The Armature produces voltage and torque under the action of the magnetic field
![Page 16: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/16.jpg)
dcmotor 16
Deriving the induced voltage in a DC Machine
![Page 17: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/17.jpg)
dcmotor 17
Deriving the electromagnetic torque in a DC Machine
![Page 18: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/18.jpg)
dcmotor 18
Voltage and Torque developed in a DC Machine
•Induced EMF, Ea = Kam (volts) •Developed Torque, Tdev = KaIa (Newton-meter or Nm)
where m is the speed of the armature in rad/sec., is the flux per pole in weber (Wb) Ia is the Armature current Ka is the machine constant
![Page 19: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/19.jpg)
dcmotor 19
Interaction of Prime-mover DC Generator and Load
Prime-mover(Turbine)
DC Generator
Loa
d
IaTdev
m Ea
+
-
VL
+
-Tpm
Ea is Generated voltageVL is Load voltageTpm is the Torque generated by Prime MoverTdev is the opposing generator torque
![Page 20: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/20.jpg)
dcmotor 20
Interaction of the DC Motor and Mechanical Load
DC MotorMechanicalLoad(Pump,Compressor)
Tload
mEa
+
- Tdev
Ea is Back EMFVT is Applied voltageTdev is the Torque developed by DC MotorTload is the opposing load torque
Ia
VT
+
--
![Page 21: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/21.jpg)
dcmotor 21
Power Developed in a DC Machine
•Input mechanical power to dc generator
= Tdev m= KaIam =Ea Ia
= Output electric power to load
•Input electrical power to dc motor
= Ea Ia= Ka m Ia = Tdev m
= Output mechanical power to load
Neglecting Losses,
![Page 22: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/22.jpg)
dcmotor 22
Equivalence of motor and generator
•In every generator there is a motor (Tdev opposes Tpm)
•In every motor there is a generator (Ea opposes VT)
![Page 23: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/23.jpg)
dcmotor 23
Example of winding specific motor and generator
Worked out on greenboard
![Page 24: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/24.jpg)
dcmotor 24
Magnetization Curve
maa KE
•Flux is a non-linear function of field current and
hence Ea is a non-linear function of field current
•For a given value of flux Ea
is directly proportional to m
![Page 25: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/25.jpg)
dcmotor 25
Field Coil
Armature
RA
Vf
Separately Excited DC Machine
+
-
![Page 26: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/26.jpg)
dcmotor 26
Shunt Field Coil Armature
RA
Shunt Excited DC Machine
![Page 27: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/27.jpg)
dcmotor 27
Series Field Coil
Armature
RA
Series Excited DC Machine
![Page 28: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/28.jpg)
dcmotor 28
Shunt Field Coil Armature
RA
Compound Excited DC MachineSeries Field Coil
•If the shunt and series field aid each other it is called a cumulativelyexcited machine•If the shunt and series field oppose each other it is called a differentiallyexcited machine
![Page 29: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/29.jpg)
dcmotor 29
Armature Reaction(AR)
• AR is the magnetic field produced by the armature current
•AR aids the main flux in one half of the pole and opposes the main flux in the other half of the pole
•However due to saturation of the pole faces the net effect of AR is demagnetizing
![Page 30: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/30.jpg)
dcmotor 30
Effects of Armature Reaction
• The magnetic axis of the AR is 900 electrical (cross) out-of-phase with the main flux. This causes commutation problems as zero of the flux axis is changed from the interpolar position.
![Page 31: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/31.jpg)
dcmotor 31
Minimizing Armature Reaction
•Since AR reduces main flux, voltage in generators and torque in motors reduces with it. This is particularly objectionable in steel rolling mills that require sudden torque increase.
•Compensating windings put on polefaces can effectively negate the effectof AR. These windings are connectedin series with armature winding.
![Page 32: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/32.jpg)
dcmotor 32
Minimizing commutation problems•Smooth transfer of current during commutation is hampered by a) coil inductance and b) voltage due to AR flux in the interpolar axis. This voltage is called reactance voltage.
•Can be minimized using interpoles. Theyproduce an opposing field that cancels out the AR in the interpolar region. Thus this winding is also connected in series with the armature winding.
Note: The UVic lab motors have interpoles in them. This should be connected in series with the armature winding for experiments.
![Page 33: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/33.jpg)
dcmotor 33
Question:
Can interpoles be replaced by compensatingwindings and vice-versa?
Why or why not?
![Page 34: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/34.jpg)
dcmotor 34
Field CoilArmature
Ra
Vf
Separately Excited DC Generator
+
-
Rf
Vt
+
-
Field equation: Vf=RfIf
If
Ia
+
-
Ea
Armature equation: Vt=Ea-IaRa
Vt=IaRL, Ea=Kam
RL
![Page 35: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/35.jpg)
dcmotor 35
Shunt Generators
Field equation: Vt=Rf If
Rf=Rfw+Rfc
Armature equation: Vt=Ea-Ia Ra
Vt=(Ia – If) RL, Ea=Kam
Shunt Field Coil Armature
Ra
RL
If IaIa – If
Vt
+
-
Rfc
Ea
+
-Field coil has Rfw :
Implicit field resistance
![Page 36: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/36.jpg)
dcmotor 36
Voltage build-up of shunt generators
![Page 37: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/37.jpg)
dcmotor 37
Example on shunt generators’ buildup
For proper voltage build-up the following are required:
• Residual magnetism
• Field MMF should aid residual magnetism
•Field circuit resistance should be less than criticalfield circuit resistance
![Page 38: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/38.jpg)
dcmotor 38
Field CoilArmature
Ra
Vf
Separately Excited DC Motor
+
-
Rf
Vt
+
-
If
Ia
+
-
Ea
Armature equation: Ea=Vt-IaRa
Ea=Kam
Field equation: Vf=RfIf
![Page 39: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/39.jpg)
dcmotor 39
Field Coil
Armature
RA
Vf
Separately Excited DC MotorTorque-speed Characteristics
+
-
m
T
TK
R
K
V
a
a
a
tm 2)(
Mechanical Load
+
-
![Page 40: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/40.jpg)
dcmotor 40
Separately excited DC Motor-Example I
A dc motor has Ra =2 , Ia=5 A, Ea = 220V, Nm = 1200 rpm. Determine i) voltage applied to the armature, developed torque,developed power . ii) Repeat with Nm = 1500 rpm. Assume sameIa.
Solution on Greenboard
![Page 41: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/41.jpg)
dcmotor 41
Speed Control of Separately Excited DC Motor(2)
•By Controlling Terminal Voltage Vt and keeping If or constant at rated value .This method of speed control is applicablefor speeds below rated or base speed.
m
VT
T1 T2 T3
T1<T2< T3
TK
R
K
V
a
a
a
tm 2)(
V1<V2<V3
V1V2 V3
![Page 42: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/42.jpg)
dcmotor 42
Speed Control of Separately Excited DC Motor
•By Controlling(reducing) Field Current If or and keeping Vt at rated value. This method of speed control is applicable for speeds above rated speed.
m
T1
T2
T3
T1<T2< T3
TK
R
K
V
a
a
a
tm 2)(
1
1> 2> 3
2
3
![Page 43: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/43.jpg)
dcmotor 43
Regions of operation of a Separately Excited DC Motor
![Page 44: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/44.jpg)
dcmotor 44
A separately excited dc motor with negligible armature resistanceoperates at 1800 rpm under no-load with Vt =240V(rated voltage). The rated speed of the motor is 1750 rpm.i) Determine Vt if the motor has to operate at 1200 rpm under no-load.ii) Determine (flux/pole) if the motor has to operate at 2400 rpm under no-load; given that K = 400/.iii) Determine the rated flux per pole of the machine.
Separately excited dc motor –Example 2
Solution on Greenboard
![Page 45: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/45.jpg)
dcmotor 45
Series Field Coil
Armature
Ra
Series Excited DC MotorTorque-Speed Characteristics
m
T
sr
aesra
sr
tm K
RRR
TK
V
Rsr Rae
-
+
![Page 46: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/46.jpg)
dcmotor 46
Losses in dc machines
![Page 47: Dc Motor power point presentation](https://reader034.vdocument.in/reader034/viewer/2022042702/55cf921e550346f57b93cd26/html5/thumbnails/47.jpg)
dcmotor 47
Losses in dc machines-shunt motorexample
Field equation: Vt=Rf If
Rf=Rfw+Rfc
Armature equation: Vt=Ea+Ia Ra
Ea=Kam
Shunt Field Coil
Armature
Ra
If IaIa – If
Vt
+
-
Rfc
Ea
+
-Field coil has Rfw :
Implicit field resistance
Mechanical Load