DESCRIPTION

The Fluorescent Assay Visualizer is a low cost, robust, field-deployable tool for interpreting high sensitivity qualitative fluorescent lateral flow or molecular assays. Significantly less expensive than a digital reader, but allowing the performance of a fluorescent test to be utilized in low cost or difficult field environments that will not support digital equipment. Omega Medical and DCN Diagnostics approached Bazza Design with a need to refine this new concept as a hand held medical device. Some basic 3D was created by Omega to prove out their concept but they realized that they needed to work out the form in a ergonomic way that was comfortable to the hand and was sized correctly to personally carry. Key Specifications: Ultra-low cost Robust to environmental conditions (heat and humidity) Resistant to drop damage Has long life Can be set up for a variety of fluorophores Can be set up to read either bare strips or cassettes Cleanable Applications Include: Infectious disease testing in field environments Biomarker testing in field environments Biowarfare agent detection and other military applications Agricultural or environmental tests Laboratory use, during development of fluorescent tests or for interpretation of qualitative fluorescent assays

TRANSCRIPT

Page 1: DCN Fluorescent Assay Visualizer

10/22/2012 1

DCN Fluorescent Assay Visualizer

DCN / Omega Medical Fluorescent Assay Visualizer

Page 2: DCN Fluorescent Assay Visualizer

10/22/2012 2

DCN Fluorescent Assay Visualizer

The Project The Fluorescent Assay Visualizer is a low cost, robust, field-deployable tool for interpreting high sensitivity qualitative fluorescent lateral flow or molecular assays. Significantly less expensive than a digital reader, but allowing the performance of a fluorescent test to be utilized in low cost or difficult field environments that will not support digital equipment.

Omega Medical and DCN Diagnostics approached Bazza Design with a need to refine this new concept as a hand held medical device. Some basic 3D was created by Omega to prove out their concept but they realized that they needed to work out the form in a ergonomic way that was comfortable to the hand and was sized correctly to personally carry. Key Specifications: Ultra-low cost Robust to environmental conditions (heat and humidity) Resistant to drop damage Has long life Can be set up for a variety of fluorophores Can be set up to read either bare strips or cassettes Cleanable Applications Include: Infectious disease testing in field environments Biomarker testing in field environments Biowarfare agent detection and other military applications Agricultural or environmental tests Laboratory use, during development of fluorescent tests or for interpretation of qualitative fluorescent assays

Patent Pending

Page 3: DCN Fluorescent Assay Visualizer

10/22/2012 3

DCN Fluorescent Assay Visualizer

Where We Started A crude proof of concept was created by Omega Medical to demonstrate the mechanical aspects of the design. Size was determined, but button location/size, viewing window location/size and overall form as it related to how it felt in the hand needed refinement. A parameter of being able to view it as it sat on a table top was also important to the form.

Page 4: DCN Fluorescent Assay Visualizer

10/22/2012 4

DCN Fluorescent Assay Visualizer

Form Studies Getting My hands dirty was called for next. Very quick form studies were created out of modeling clay. Size and form fit to the hand was explored as well as part line and assembly concerns. Below are a few of the “Fast Forms” created. They helped immeasurably in defining the sketch studies that came next.

Page 5: DCN Fluorescent Assay Visualizer

10/22/2012 5

DCN Fluorescent Assay Visualizer

Concept Studies Quick pencil sketching for form and feature study.

Page 6: DCN Fluorescent Assay Visualizer

10/22/2012 6

DCN Fluorescent Assay Visualizer

Chosen Form This set of sketches were chosen for theme refinement. Some details were carried over as is but others evolved in the 3D development created next.

Page 7: DCN Fluorescent Assay Visualizer

10/22/2012 7

DCN Fluorescent Assay Visualizer

3D Development The two chosen concepts translated well in 3D. Hand grip details and a “hole” for hanging the design on a belt loop was added in this refinement phase.

Concept 1 Concept 2

Page 8: DCN Fluorescent Assay Visualizer

10/22/2012 8

DCN Fluorescent Assay Visualizer

3D Development Refinement continued with button details, part lines, battery hatches and lenses.

Concept 1 Concept 2

Page 9: DCN Fluorescent Assay Visualizer

10/22/2012 9

DCN Fluorescent Assay Visualizer

Final Design The chosen design is finalized in 3D and released for prototype.

Page 10: DCN Fluorescent Assay Visualizer

10/22/2012 10

DCN Fluorescent Assay Visualizer

Final Design Here the chosen design is depicted with the reader strip cartridge in place.

Page 11: DCN Fluorescent Assay Visualizer

10/22/2012 11

DCN Fluorescent Assay Visualizer

Final Design Renderings were created for DCN’s Website to demonstrate the insertion of the cartridge into the IR reader.

Page 12: DCN Fluorescent Assay Visualizer

10/22/2012 12

DCN Fluorescent Assay Visualizer

Final Design Prototypes were created for testing and review with the customer.

Page 13: DCN Fluorescent Assay Visualizer

10/22/2012 13

DCN Fluorescent Assay Visualizer

Final Design Prototypes were created for testing and review with the customer.