dcnng multi ccu system setup
DESCRIPTION
DCNNG Multi CCU System Setup. DCNNG Multi CCU System Setup. A basic multi-CCU system. The following can be connected to a multi-CCU system: A maximum of 30 DCN-CCU devices. A maximum of 4000 delegate positions (Stand-alone and Microphone function only). - PowerPoint PPT PresentationTRANSCRIPT
1 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Communications Systems DCN Next GenDCN Next Gen
DCNNG Multi CCU System Setup
2 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Communications Systems
DCNNG Multi CCU System Setup
A basic multi-CCU system.
• The following can be connected to a multi-CCU system:
- A maximum of 30 DCN-CCU devices.
- A maximum of 4000 delegate positions (Stand-alone and Microphone function only).
- A maximum of 1500 delegate positions with PC control.
- A maximum of 32 audio channels (1 Floor and 31 channels for Interpretation).
3 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Communications Systems
AutoDome
RS 232
For redundancy only
Seat 246 Seat 490
CCU 2
Seat 1
CCU 1
Seat 245
OptionalPC
ControlEthernet link
DCNNG Multi CCU System with 490 Concentus units
Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units are active units)
DCN-NCO
4 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Communications Systems
AutoDome
RS 232
Audio Expander
CCU 2
Seat 246 Seat 426 IDESK 1 IDESK 64
CCU 1
Seat 1 Seat 245
OptionalPC
ControlEthernet link
DCNNG Multi CCU System with 426 Concentus units and 64 Interpreter Desks
Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units)
DCN-NCO
5 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Communications Systems
DCNNG Multi CCU System with 490 Concentus units and # Interpreter Desks
Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units)
1 n
Seat 1 Seat 245
Seat 246 Seat 490
DCN-NCO
CCU 1
CCU 2
CCU 3
AutoDome
RS 232
OptionalPC
ControlEthernet link
6 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Communications Systems
CCU 3
1 n 1 n
Room 3
CCU 2
1 n 1 n
Room 2
DCNNG Multi CCU System Single Room or combined Rooms
Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units) Interlock between booths on separate CCU‘s cannot be used in “None” - mode.
DCN-NCO
CCU 1
1 n 1 n
Room 1
7 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Communications Systems
DCNNG Multi CCU System up to 1225 seats
Up to 245 addresses can be connected to one CCU. DCN Dual Delegates Units use an address. Each unit controls two seat numbers.
Seat 1 & 2
Seat 979 & 980
Seat 489 & 490
Seat 491 & 492
Unit 1 Unit 245
Unit 1 Unit 245
DCN-NCO
CCU 1
CCU 2
CCU 3
Seat 1224 & 1225Seat 981 & 982
Unit 1 Unit 245
AutoDome
RS 232
OptionalPC
ControlEthernet link
8 DCNNG MCCU System SetupST/PRM3-EU | |12.Mar.07 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Communications Systems
DCNNG Multi CCU System Setup
End of section
MCCU Menu