DCPS Telecom DC Power Systems
1
About Us
Since 1945, La Marche has been providing reliable power conversion products. We are dedicated to the development and production of innovative quality products to meet our customer’s electrical power requirements. La Marche products include battery chargers, rectifiers, power supplies, inverters and others. We serve the Utility, Telecommunication, Engine Start, Material Handling, Railroad, Marine, and Mining markets.
La Marche integrated DC Power systems provide power needs for telecom, cable and microwave networks. For over 70 years, La Marche has delivered customized systems to suit any telecom application. La Marche DC power systems offer high reliability, high efficiency, high power density rectifiers, DC to DC converters, distribution centers, and supervisory modules.
THE POWERFUL
ADVANTAGE
RELIABILITY YOUCAN TRUST
CUSTOM SOLUTIONS TECHNOLOGY
U.S. COMPANY 24 HOUR SERVICE
DC Power Systems200 Amp
2
Custom Modular 200A - 800A Systems
Custom Modular High Power DC Systems
Complete and Stand Alone 200A SystemUp to 12kW @ -48Vdc Universal Rectifier AC InputController with Battery and Load Management and Protection Modes Alarm Dry Output and Input Contacts, and Sensor Inputs Web User Interface and SNMP Communication Protocol16 Pluggable Load Breakers and 2 Battery BreakersLVBD (Low Voltage Battery Disconnect)DC Surge ProtectionRack Mount; 4RU 19” or 23”
12kW – 48kW @ -48Vdc200 Amp @ -48Vdc Per Rectifier ShelfOne or Two 600A Distribution Tiers20 Breaker Positions per TierLow Voltage Disconnect (LVD) Contactor per TierUniversal Rectifier AC InputController with Battery and Load Management and Protection ModesAlarm Dry Output and Input Contacts, and Sensor InputsWeb User Interface and SNMP Communication ProtocolOpen Rack or NEMA rated EnclosuresBattery Trays with Disconnect Breakers
Up to 100kW systems200 Amp @ -48Vdc Per Rectifier Shelf600A per Tier for Distribution24 Breaker positions per TierLVD Contactors 23” Frame Enclosed Cabinet
Shown above: DCPS-4RU-200A
Shown above: 400A DC System Examples
400A Open Rack System
400A NEMA 4 System
DC Power System ComponentsDC Power System Components
3
La Marche offers Power Systems of multiple sizes of rectifiers, converters, inverters and feature loaded distribution panels (LVD, Ground/Charge Busbars, etc.)
Charge Busbarsand Ground Busbars
Distribution Center:• Plug-in Load Breakers• LVLD/LVBD
Control Unit:• System Controller with monitoring capabilities• Communication Ports• Alarm Contacts• Sensor Inputs
Power Equipment:• Rectifiers• Converters• Inverters
Breaker Panels:• Battery Disconnect Main Breakers• Load Disconnect Main Breakers
Battery Trays
Cabinets:• NEMA and IP Rated Enclosures• Seismic Relay Rack
Example Block Diagram
LOWVOLTAGE
DISCONNECT
ControllerController (DCSC)
La Marche’s DC System Controller (DCSC) is an intelligent module that monitors and manages La Marche DC power systems. The controller provides the system with Battery Management, Energy Conservation, Rectifier Management, Intelligent Battery Hibernation Mode, Battery Testing, Battery Charging, and Current Limiting controls.
System configuration settings and real-time parameters can be accessed either locally (through a two-line LCD display), or remotely (through a Web User Interface).
(1) Run Indicator(2) Minor Alarm Indicator(3) Major Alarm Indicator(4) Control Buttons(5) USB port
(6) RS485/RS232 Port(7) Handle(8) Locking Latch(9) Fast Ethernet (FE) Port(10) LCD
Controller Indicator Description
Indicator
Run Indicator
Minor AlarmIndicator
Major AlarmIndicator
Color Status
Green
Off
Steady OnOff
Red
Yellow
Description
Blinking at0.5 Hz
Blinking at 4 HzOff
Steady On
Controller OFF
Controller communicating properly
Controller ON but not communicating properly
No minor alarm(s)
Minor alarm(s) generated
No critical or major alarm(s)Critical or major alarm(s) generated
DCU I/O Interface Module
Equipped with the I/O module (DCU), the controller supports configurable digital inputs, alarm dry-contacts and site sensor ports for environment management and alarms reporting. The DCU I/O module provides the ability to add multiple sensors for: ambient temperature, humidity, water, door status, smoke and battery temperature. The dry-contacts alarm are configurable and can be customized upon the DC system’s requirements. All alarms can be easily configured and monitored remotely through the WebUI (Web User Interface).
DCU Port Description
Port Type Silk Screen DescriptionTEM-HUMWATERTEMP1TEMP2GATESMOKEBTEMPDIN1DIN2DIN3DIN4DIN5DIN6ALM1ALM2ALM3ALM4ALM5ALM6ALM7ALM8COM
Ambient Temp. and humidity sensorWater SensorAmbient Temperature Sensor 1Ambient Temperature Sensor 2Door Status SensorSmoke SensorBattery Temperature SensorDry Contact Input 1Dry Contact Input 2Dry Contact Input 3Dry Contact Input 4Dry Contact Input 5Dry Contact Input 6Dry Contact Output 1Dry Contact Output 2Dry Contact Output 3Dry Contact Output 4Dry Contact Output 5Dry Contact Output 6Dry Contact Output 7Dry Contact Output 8RS485 Port
Sensor Port
Dry Contact Input
NOTE: For details aboutthe signal definitions, see the power system user manual
Dry Contact Output
NOTE: For details aboutthe alarms associated with drycontact outputs, see the power system user manual
Communication Port
123
4
ControllerController Features
Mechanical
.
Grid Quality Detection Battery ManagementAC Input Voltage
AC Input Current
AC Frequency
DC Output Voltage
Total Load Current
Total Battery Current
Battery Current
Battery Temperature
Ambient Temperature
Rectifier Hibernation
Rectifier Operation Information
Rectifier Power-On/Off Control
Rectifier Output Voltage and Current Limit
Rectifier Overvoltage Protection
Sequential Rectifier Startup
Battery Hibernation
Battery Control
Battery Charging
Battery Test
Battery Current Limiting
Battery Temperature Compensation
Battery High Temperature Protection
Multi-Mode & Multi-Level Disconnecting Protection
Battery Imbalance Detection
Battery Capacity Calculation/Backup Time Calculation
Internal Fault
AC Phase Failure
AC/DC Overvoltage/Undervoltage
Load/Battery Fuse Break
Battery Discharging
Low Voltage Battery Disconnect (LVBD)
Battery Temperature High/Very High/Low/Very Low
Rectifier Failure
Rectifier Communication Failure
No Redundant Rectifiers
AC/DC Surge Protection Device (SPD) Failure
Energy Conservation Management
Rectifier Management
Alarm
Overall Dimensions: (W x D x H)
7.6” x 1.6” x 3.9”194.3 x 40.8 x 99mm
Grid Quality Detection
Weight: 3.3lb (1.5kg)
Natural Cooling
Low Voltage Load Disconnects (LVLD1, LVLD2)
The Controller is Hot Swappable
5
ControllerCommunication Ports
Web User Interface
The Web User Interface allows for a secure password protected remote access to the DC system for monitoring and control purposes. The WebUI provides system’s running parameters, active alarms and configurations. Various settings can be configured using the WebUI. Settings include: alarm parameters and configurations, rectifier management, battery management and communications settings.
The WebUI provides flexible alarm configuration settings that includes a PLC (Programmable Logic Controller) programming tool.
Communication Ports
FE port
RS485/RS232 port
Communication Parameter Communication Protocol
10/100M auto-adaptation
Baude rate: 9600 bit/s
HTTPS and SNMP
Master/slave protocols
NOTE: All ports are protected by a security mechanism.
6
RectifierRectifier (DCR)
3500
500
1000
1500
2000
3000
2500
40 50 55 65 75
100%80%60%40%20%
10098969492908886848280
The DCR50 rectifier converts AC power to DC power and delivers high performance features, such as high efficiency (>96%), high power density, walk-in start, complete protection and low noise. The output voltage of the rectifiers can be adjusted through the DC System controller. The rectifier is hot swappable, providing easy installation and maintenance.
High Efficiency Exceeds 96%
Universal AC Input
Operating Temperature Range: -40 to 65°C
Total Harmonic Distortion (THD): <5%
Hot Swappable
Communication Over CAN
Meets RoHS Requirements
TUV, CE, CB, UL Recognized
40
45
50
55
60
5 10 15 20 25 30 35 40 45 50 55 60 65
Output Feature
Efficiency Curve
Power Derating Curve
Current / A
Load Rate
Temperature/℃
Volta
ge/V
Pow
er/W
Features
7
RectifierRectifier Specifications
W eight ≤4.4lb (≤2kg)
Cooling
Forced Air Cooling
Input voltage 85-300 VAC
Frequency
45-66 Hz
Maximum input current
≤17A
Power factor
≥0.99
THD
≤5%
Output voltage
42-58 VDC, Nominal: 54 VDC
Output power
55A @ 54V (176-300 VAC)Linearly derated to 23A @ 54V (85-175 VAC)
Operating temperature
Storage temperature
Relative humidity
Altitude
Input overvoltage protection 300 VAC
Input undervoltage protection 80 VAC
Output overvoltage protection 58.5-60.5 VDC
Output short circuit protection
Over-temperature protection
MTBF
>500,000 hours
≤55dB (40℃, Full Load)
Safety certification
EMC
AC Input
Protection
Reliability
Safety/emc/Lightning Protection
Mechanical
DC Output
Environmental
Audible Noise
Overall Dimension(W x D x H)
4.1” x 11.1” x 1.6”105 x 281 x 40.8mm
5% - 95% (Non-Condensing)Up to 6,562ft (Derate Operating Temperature by 1°C/656ft for 6,562ft-13,123ft)
-40 to 65°C (-40 to 149°F), Derated Output Above 55°C (131°F)
-40 to 75°C (-40 to 167°F)
TUV, CE, UL UL60950-1IEC60950-1EN60950-1CAN/CSA C22.2 No. 60950-1 EN55022 Class BEN55024EN61000-3-2EN61000-3-3ETSI EN300 386ETSI EN301489ITU-T K.20
Lightning protection YD 5098-2005 5KA
Efficiency >96%
8
Other ComponentsDC Distribution
Battery Tray
La Marche Relay Rack Mounted Battery Trays are beneficial if floor space is confined and batteries are to be mounted directly in the DC power system equipment racks.
Battery Disconnects
Constructed from 12 Gauge Steel
ANSI-61 Gray Paint Finish
Assembly and Mounting Hardware
Welded Corners
600 lbs Weight Capacity
Available with Battery Disconnects
Features
Plug-In Breakers
Breaker Positions Required:
1A - 100A125A - 200A
= 1 Position= 2 Positions
Available Breaker Current Ratings1A, 2A, 3A, 5A, 10A, 15A, 20A, 25A, 30A, 35A, 40A, 50A, 60A, 70A, 80A, 100A, 125A, 150A, 200A
9
Highly Customizable Distribution
Positive Ground Detection
600A Distribution Tier with Plug-in Type Breakers
LVBD (Low Voltage Battery Disconnects)
LVLD (Low Voltage Load Disconnects)
Current Sensing
Load Breakers
Battery Breakers
Charge and Ground Busbars
EnclosuresEnclosure Information
La Marche Manufacturing offers Complete Power Systems; including Battery Chargers, Rectifiers, Converters, Inverters, Batteries and Distribution in Indoor and Outdoor Cabinets. La Marche Power Systems are available in multiple arrangements in order to meet different applications’ specific requirements. Cabinets are available in NEMA 1, NEMA 3(R), NEMA 4(X), NEMA 12 and IP ratings.
Different NEMA ratings provide different levels of protection against environmental conditions as described below and in NEMA Standards Publication 250-2003, “Enclosures for Electrical Equipment (1000 Volts Maximum)”.
NEMA 1 is a basic general purpose indoor enclosure designed to protect people from incidental contact with the components inside as well as a degree of protection against solid objects.
NEMA 3R is a basic outdoor enclosure designed to protect the enclosed equipment against rain. It provides protection against falling dirt, rain, sleet and snow.
NEMA 4 is a watertight and dust tight enclosure. It provides protection against falling dirt, windblown dust, rain, sleet, snow, splashing water and hose directed water. NEMA 4(X) provides protection against corrosion.
NEMA 12 is a dust tight and drip tight enclosure intended for indoor use. It provides protection against falling dirt, circulating dust, lint, fibers, and dripping water.
*NEMA 3R, 4 and 12 also provide protection for people against incidental contact with internal components.
Shown above: NEMA 4
Shown above: NEMA 4
Shown above: NEMA 3R
10
La Marche Mfg. (A U.S. Company) 106 Bradrock Drive, Des Plaines, IL 60018Tel: 001.847.299.1188Fax: [email protected]
La Marche DC Systems