ddl.mocom2012 brochure
DESCRIPTION
MOCOM PRODUCT RANGE 2011 Millennium Sterilizers Millseal Plus Thermosealers Millseal Rolling Mocom srl www.mocom.it Millennium B Millennium B+ Millennium B2 Mocom srl www.mocom.it • Patented instant Steam Generator giving high quality saturated steam • Top-performance dual headed Vacuum Pump • Patented Hydraulic Circuit Mocom srl www.mocom.it Automated door lock Patented electromechanical system with triple protection • Completely sealed chamber • Gasket preservation Mocom srl www.mocom.itTRANSCRIPT
![Page 1: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/1.jpg)
MOCOM PRODUCT RANGE 2011
Millennium Sterilizers
Millseal Plus Thermosealers
Millseal RollingMocom srl www.mocom.it
![Page 2: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/2.jpg)
Millennium BMillennium B+Millennium B2
Mocom srl www.mocom.it
![Page 3: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/3.jpg)
• Patented instant Steam Generator giving high quality
saturated steam
• Top-performance dual headed Vacuum Pump
• Patented Hydraulic Circuit
Mocom srl www.mocom.it
• More rapid sterilization cycle (30% less than a traditional B cycle)• Water (0,5 l per cycle) and energy saving• Cycles performing without waiting time
![Page 4: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/4.jpg)
Automated door lockPatented electromechanical system with triple protection• Completely sealed chamber
• Gasket preservation
Mocom srl www.mocom.it
Sterilization chamberMade of electro-polished stainless steel
Rotating stainless steel framefor:• 5 trays• 3 cassettes
![Page 5: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/5.jpg)
Optimized dryingThe autoclave automatically selects the most suitable drying system, according
to the load quantity.
Steel wire traysFor a better steam flow inside the
chamber in order to perform an optimal drying phase.
Mocom srl www.mocom.it
![Page 6: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/6.jpg)
Mocom srl www.mocom.it
Control PanelThe new control panel makes the autoclave use easier, enabling a rapid and intuitive selection of the menu items.
•10 languages
• Easy selection of the pre-set cycles
• Visualization of the automatic system of programmed maintenance
![Page 7: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/7.jpg)
Removable handles• The transport and installation phases are made even simpler
by the handles on the top of the autoclave.
• After positioning the autoclave in the sterilization area, the
handles can be easily removed.
Mocom srl www.mocom.it
![Page 8: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/8.jpg)
Record of the cycle information
• Print on paper
• Saving in digital format on a USB Pen Drive
Mocom srl www.mocom.it
Software updating through the special integrated connection
![Page 9: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/9.jpg)
PROCESS EVALUATION SYSTEM(in accordance with the EN 13060 standard)
• Accurate cross control of the main parameters (temperature, pressure and time)
• Immediate indication of any anomalies during the sterilization cycle.
Mocom srl www.mocom.it
PROGRAMMED MAINTENANCE
Self-testing system signaling the need for maintenance:• Cleaning of chamber filter (after 200 cycles)
• Replacement of bacteriologic filter (after 400 cycles)• Replacement of door gasket (after 1000 cycles)
• General servicing (after 3000 cycles)
![Page 10: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/10.jpg)
CERTIFIED PRODUCTION AND TESTINGBefore being approved for use, each Mocom autoclave is tested for 7 hours in compliance with the EN 13060 standard. The specific document relating
to the “Works Test” (upon request) is supplied together with the autoclave.
Mocom srl www.mocom.it
![Page 11: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/11.jpg)
STERILIZATION CYCLES
11 Sterilization Cycles with number of vacuum pulses and duration of the drying phase according to the material to be sterilized
4 pre-set cycles• Cycle B 134° UNIVERSAL with standard drying• Cycle B 121° UNIVERSAL with standard drying• Cycle B Prion• Cycle Emergency7 programmable cycles
Mocom srl www.mocom.it
At the end of the cycle, the autoclave goes into a stand-by mode. Automatic shutdown function also available.
![Page 12: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/12.jpg)
AUTOCLAVE PERFORMANCES EVALUATION
2 pre-set cycles
• Helix e Bowie&Dick Test
• Vacuum Test
Mocom srl www.mocom.it
![Page 13: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/13.jpg)
The autoclaves characterized by high performances and low consumptions, in the most simple configuration.
Mocom srl www.mocom.it
Millennium BMillennium B+Millennium B2
STAND-ALONE VERSION
![Page 14: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/14.jpg)
• Installation in any position by simply connecting the autoclave to a power outlet.
• Practical opening on top for the demineralized water pouring directly into
the tank.
• Alternatively, an auxiliary pump is also available for automatically pumping water
from an external tank that can be connected to the back of the autoclave.
Mocom srl www.mocom.it
![Page 15: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/15.jpg)
Mocom srl www.mocom.it
The remaining water can be discharged through the front
connection, or through a special connection on the back of the autoclave that
can be directly connected to the drainpipes.
![Page 16: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/16.jpg)
The completely autonomous autoclaves, providing considerable time saving and optimization of the operating phases.
Mocom srl www.mocom.it
Millennium BMillennium B+Millennium B2
MILLENNIUM WITH MOCOPURE 100
![Page 17: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/17.jpg)
Mocom srl www.mocom.it
MOCOPURE 100
• Demineralization system made up of two resin cartridges with ionic exchange for the production of high quality demineralized water.
•In-built conductivity sensor.
• Autonomy of 250-350 cycles (based on the quality and hardness of the water from the mains supply and on the type of cycle).
![Page 18: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/18.jpg)
Mocom srl www.mocom.it
MOCOPURE 100
• Directly connected to the autoclave and operated by 2 AA batteries.
•Acoustic and light signals indicating when it is necessary to replace the cartridges or batteries.
•Easy filter replacement with the aid of the specific tool included.
![Page 19: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/19.jpg)
Mocom srl www.mocom.it
The remaining water can be discharged through the front
connection, or through a special connection on the back of the autoclave that
can be directly connected to the drainpipes.
![Page 20: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/20.jpg)
Mocom srl www.mocom.it
The most eco-friendly demineralization system, with the ideal autonomy for several sterilization cycles a day.
MILLENNIUM WITH MOCOPURE 500
Millennium BMillennium B+Millennium B2
![Page 21: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/21.jpg)
Mocom srl www.mocom.it
MOCOPURE 500
• Based on the principle of reverse osmosis which eliminates all the organic and inorganic substances.
• Autonomy of 1200-1500 cycles (based on the quality and hardness of the water from the mains supply and on the type of cycle).
• In-built conductivity sensor.
• Free positioning.
![Page 22: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/22.jpg)
Mocom srl www.mocom.it
MOCOPURE 500
• Directly connected to the autoclave and operated by 2 AA batteries.
• Acoustic and light signals indicating when it is necessary to replace the cartridges or batteries.
![Page 23: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/23.jpg)
Mocom srl www.mocom.it
The remaining water can be discharged through the front
connection, or through a special connection on the back of the autoclave that
can be directly connected to the drainpipes.
![Page 24: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/24.jpg)
Mocom srl www.mocom.it
Products in compliance with the followingregulations:• 1993/42/CEE Medical Device Directive(as further amended and extended)• 2007/47/CE Medical Device Directive• 2004/108/CE ElectromagneticCompatibility Directive• 2006/95/CE Low Voltage Directive• EN 13060: Small steam sterilizers• EN 61010- 1: Safety requirements forelectrical equipment for laboratory use• EN 61010-2-040: Particular safetyrequirements for steam sterilizers
A quality production guaranteed by strict certifications and approvals, including:• ISO 9001/ISO 13485: Quality System applied to Medical Devices• CE 0051: Approval of Medical Devices for the European Community• FDA: Approval of Medical Devicesfor the USA• Health Canada: Approval of Medical Devices for Canada• TGA: Approval of Medical Devices for Australia
Mocom is a leading manufacturer of innovative sterilizers that focus on quality, innovation and design
![Page 25: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/25.jpg)
Mocom srl www.mocom.it
Millseal Plus Thermosealers
Millseal Plus ManualMillseal Plus Automatic
![Page 26: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/26.jpg)
Mocom srl www.mocom.it
Millseal Plus Manual
• Electronic control of the sealing parameters (time and temperature).
• 12 mm sealing band.
• Acoustic and visual signals providing information about the proper operative conditions.
• Ergonomic and practical design.
![Page 27: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/27.jpg)
Mocom srl www.mocom.it
Millseal Plus Manual• Automatic adjustment of the temperature for an effective control of the sealing area heating.
• Safety device against overheating.
• Automatic stand-by mode for energy saving.
• The position maintenance system of the rolls avoid their re-winding after the cut and sealing steps.
• The metric scale on the resting plate helps in defining with precision the proper length of the bags.
![Page 28: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/28.jpg)
Mocom srl www.mocom.it
Millseal Plus Automatic• Automatic unit that allows the operator to perform the whole procedure by means of simple keys.
![Page 29: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/29.jpg)
Mocom srl www.mocom.it
Millseal Plus Automatic
![Page 30: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/30.jpg)
Mocom srl www.mocom.it
Millseal Rolling
![Page 31: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/31.jpg)
Mocom srl www.mocom.it
Millseal Rolling
![Page 32: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/32.jpg)
Mocom srl www.mocom.it
Millseal Rolling• New compact continuous sealing machine
• The ideal solution for daily sealing of high quantities of pouches
• Automatic infeed through a photocell • 12 mm multi-line seal
• Adjustable edge 0÷20 mm• Infeed speed 10 m/min (approx. 3’’ per pouch)
• Integrated printer that automatically prints on the pouch all the data chosen by the operator
![Page 33: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/33.jpg)
Mocom srl www.mocom.it
Millseal Rolling• New friendly-user graphic interface with
selectable parameters:•User
•Temperature•Settings
•Expiry date•Batch number
•Notes•Printer•Clock
![Page 34: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/34.jpg)
Mocom srl www.mocom.it
Millseal Rolling
Available by the end of 2011
![Page 36: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/36.jpg)
Mocom srl www.mocom.it
Work in progress
![Page 37: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/37.jpg)
Mocom srl www.mocom.it
Thermo-disinfector
![Page 38: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/38.jpg)
Mocom srl www.mocom.it
Automatic Thermosealer
![Page 39: DDL.MOCOM2012 BROCHURE](https://reader031.vdocument.in/reader031/viewer/2022020210/568c4c551a28ab49169fba58/html5/thumbnails/39.jpg)
Mocom srl www.mocom.it
New sterilizer with display