dell 8.3.5.6 command line reference guide for the …...navigating the command line interface the...

1134
Dell Command Line Reference Guide for the S55 System 8.3.5.6

Upload: others

Post on 21-Jun-2020

21 views

Category:

Documents


0 download

TRANSCRIPT

  • Dell Command Line ReferenceGuide for the S55 System

    8.3.5.6

  • Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

    CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

    WARNING: A WARNING indicates a potential for property damage, personal injury, or death.

    Information in this publication is subject to change without notice.© 2014 Dell Force10. All rights reserved.

    Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.

    Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®, Xeon®, Core® and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD®is a registered trademark and AMD Opteron™, AMD Phenom™ and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, Internet Explorer®, MS-DOS®, Windows Vista® and Active Directory® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat® and Red Hat®Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® and SUSE® are registered trademarks of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware®, Virtual SMP®, vMotion®, vCenter® and vSphere® are registered trademarks or trademarks of VMware, Inc. in the United States or other countries. IBM® is a registered trademark of International Business Machines Corporation.

    Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

    November 2014

  • | 3

    1 About this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Information Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

    2 CLI Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Accessing the Command Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Multiple Configuration Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Navigating the Command Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14Obtaining Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Using the Keyword No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Filtering show Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

    Displaying All Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Filtering Command Output Multiple Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

    Command Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18EXEC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19EXEC Privilege Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19CONFIGURATION Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19INTERFACE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19LINE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20TRACE-LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20MAC ACCESS LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20IP ACCESS LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21ROUTE-MAP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21PREFIX-LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21AS-PATH ACL Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21IP COMMUNITY LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22REDIRECT-LIST Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22SPANNING TREE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22Per-VLAN SPANNING TREE Plus Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22RAPID SPANNING TREE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23MULTIPLE SPANNING TREE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23PROTOCOL GVRP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23ROUTER OSPF Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23ROUTER RIP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24ROUTER BGP Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

    Determining the Chassis Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

    3 File Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25Basic File Management Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

  • 4 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om 4 Control and Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

    Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67

    5 802.1ag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163

    6 802.1X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175

    7 Access Control Lists (ACL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191Commands Common to all ACL Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191Common IP ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193Standard IP ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197Extended IP ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204Common MAC Access List Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235Standard MAC ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .238Extended MAC ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242IP Prefix List Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248Route Map Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254AS-Path Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .272IP Community List Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .276

    8 Border Gateway Protocol IPv4(BGPv4) . . . . . . . . . . . . . . . . . . . . . . . . .281Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .281BGPv4 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282MBGP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .358BGP Extended Communities (RFC 4360) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383

    9 Bare Metal Provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .393

    10 Content Addressable Memory (CAM) . . . . . . . . . . . . . . . . . . . . . . . . . . .399Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399CAM Profile Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .399

  • | 5

    11 Dynamic Host Configuration Protocol (DHCP) . . . . . . . . . . . . . . . . . . . .413Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .413Commands to Configure the System to be a DHCP Server . . . . . . . . . . . . . . . . . . . . .413Commands to Configure Secure DHCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .421

    12 Dell Force10 Resilient Ring Protocol (FRRP) . . . . . . . . . . . . . . . . . . . . .427Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .427Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .427

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .427

    13 GARP VLAN Registration (GVRP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .435Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .435Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .435

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .436

    14 Internet Group Management Protocol (IGMP) . . . . . . . . . . . . . . . . . . . .445Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445IGMP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445IGMP Snooping Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .456

    Important Points to Remember for IGMP Snooping . . . . . . . . . . . . . . . . . . . . . . . .456Important Points to Remember for IGMP Querier . . . . . . . . . . . . . . . . . . . . . . . . . .456

    15 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .461Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .461Basic Interface Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .461Port Channel Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .517

    16 IPv4 Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .527Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .527Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .527

    17 IPv6 Access Control Lists (IPv6 ACLs) . . . . . . . . . . . . . . . . . . . . . . . . .579Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .579

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .579IPv6 ACL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .579IPv6 Route Map Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .604

    18 IPv6 Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .609Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .609Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .609

  • 6 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om 19 iSCSI Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .621

    Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .621

    20 Link Aggregation Control Protocol (LACP) . . . . . . . . . . . . . . . . . . . . . . .629Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .629Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .629

    21 Layer 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .637Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .637MAC Addressing Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .637Virtual LAN (VLAN) Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .655

    22 Link Layer Detection Protocol (LLDP). . . . . . . . . . . . . . . . . . . . . . . . . . .665Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .665Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .665LLDP-MED Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .676

    23 Multiple Spanning Tree Protocol (MSTP) . . . . . . . . . . . . . . . . . . . . . . . .685Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .685Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .685

    24 Multicast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .699Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .699IPv4 Multicast Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .699IPv6 Multicast Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .707

    25 Neighbor Discovery Protocol (NDP) . . . . . . . . . . . . . . . . . . . . . . . . . . . .713Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .713Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .713

    26 Open Shortest Path First (OSPFv2 and OSPFv3) . . . . . . . . . . . . . . . . .721Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .721OSPFv2 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .721

    27 PIM-Sparse Mode (PIM-SM). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .779Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .779IPv4 PIM-Sparse Mode Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .779

    28 PIM-Source Specific Mode (PIM-SSM). . . . . . . . . . . . . . . . . . . . . . . . . .795Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .795IPv4 PIM Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .795

  • | 7

    IPv4 PIM-Source Specific Mode COmmands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .795

    29 Port Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .799Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .799Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .799

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .799

    30 Private VLAN (PVLAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .805Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .805Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .805

    Private VLAN Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .805

    31 Per-VLAN Spanning Tree plus (PVST+) . . . . . . . . . . . . . . . . . . . . . . . . .815Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .815Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .815

    32 Quality of Service (QoS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .827Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .827Global Configuration Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .827Per-Port QoS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .828Policy-Based QoS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .836

    Important Points to Remember—multicast-bandwidth option . . . . . . . . . . . . . . . . .850Queue-Level Debugging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .872

    33 Router Information Protocol (RIP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . .885Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .885Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .885

    34 Remote Monitoring (RMON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .905Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .905Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .905

    35 Rapid Spanning Tree Protocol (RSTP) . . . . . . . . . . . . . . . . . . . . . . . . . .917Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .917Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .917

    36 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .927Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .927Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .927AAA Accounting Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .927Authorization and Privilege Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .930

  • 8 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Authentication and Password Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .934

    RADIUS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .946TACACS+ Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .951Port Authentication (802.1X) Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .954

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .954SSH Server and SCP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .962Secure DHCP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .974

    37 Service Provider Bridging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .979Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .979Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .979

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .979

    38 sFlow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .985Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .985

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .985Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .986

    39 SNMP and Syslog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .995Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .995SNMP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .995

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .996Syslog Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1011

    40 Storm Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1025Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1025Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1025

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1025

    41 S-Series Stacking Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1035Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1035Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1035

    42 Spanning Tree Protocol (STP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1049Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1049Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1049

    43 Time and Network Time Protocol (NTP) . . . . . . . . . . . . . . . . . . . . . . . .1059Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1059Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1059

  • | 9

    44 S55 u-Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1075Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1075Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1075

    45 Uplink Failure Detection (UFD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1081Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1081Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1081

    46 VLAN Stacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1091Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1091Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1091

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1091

    47 Virtual Router Redundancy Protocol (VRRP) . . . . . . . . . . . . . . . . . . . .1101Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1101Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1101

    48 S-Series Debugging and Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . 1113Diagnostics and Monitoring Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1113Offline Diagnostic Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1114

    Important Points to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1114Buffer Tuning Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1116Hardware Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1121

    49 SNMP Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1131

  • 10 |

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om

  • About this Guide | 11

    1About this Guide

    This book provides information on the FTOS Command Line Interface (CLI). It includes some information on the protocols and features found in FTOS and on the Dell Networking systems supported by FTOS (C-Series c, E-Series e, and S-Series s).

    This chapter includes:

    • Objectives• Audience• Conventions• Related Documents

    ObjectivesThis document is intended as a reference guide for the FTOS command line interface (CLI) commands used with the S55 system.

    AudienceThis document is intended for system administrators who are responsible for configuring or maintaining networks. This guide assumes you are knowledgeable in Layer 2 and Layer 3 networking technologies.

    ConventionsThis document uses the following conventions to describe command syntax:

    Convention Description

    keyword Keywords are in bold and should be entered in the CLI as listed.parameter Parameters are in italics and require a number or word to be entered in the CLI.{X} Keywords and parameters within braces must be entered in the CLI.

    [X] Keywords and parameters within brackets are optional.

    x | y Keywords and parameters separated by bar require you to choose one.

    x||y Keywords and parameters separated by a double bar enables you to choose any or all of them.

  • 12 | About this Guide

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Information Symbols

    Table 1-1 describes symbols contained in this guide.

    Related DocumentsFor more information about the system, refer to the following documents:

    • FTOS Configuration Guide for the S55• S55 Installation Guide• Release Notes for FTOS

    Table 1-1. Information Symbols

    Symbol Brief Description

    c C-Series This symbol indicates that the selected feature is supported on the C-Series.

    e E-Series This symbol indicates that the selected feature is supported on the E-Series TeraScale AND E-Series ExaScale.

    et E-SeriesTeraScale

    This symbol indicates that the selected feature is supported on the E-Series TeraScale platform only.

    ex E-SeriesExaScale

    This symbol indicates that the selected feature is supported on the E-Series ExaScale platform only.

    s S-Series This symbol indicates that the selected feature is supported on the S-Series. Note that when a feature is supported on all the S-Series systems, including the S55, this symbol is used.

    S55 This symbol indicates that the selected feature is supported on the S55 but not on other S-Series systems.

  • CLI Basics | 13

    2CLI Basics

    This chapter describes the command structure and command modes. FTOS commands are in a text-based interface that allows you to launch commands, change the command modes, and configure interfaces and protocols.

    This chapter covers the following topics:

    • Accessing the Command Line• Multiple Configuration Users• Navigating the Command Line Interface• Obtaining Help• Using the Keyword No• Filtering show Commands• Command Modes

    Accessing the Command LineWhen the system boots successfully, you are positioned on the command line in the EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session. When you Telnet into the switch, you are prompted to enter a login name and password.

    Figure 2-1 is an example of a successful Telnet login session.

    Figure 2-1. Login Example

    Once you log into the switch, the prompt provides you with current command-level information (refer to Table 2-1).

    telnet 172.31.1.53Trying 172.31.1.53...Connected to 172.31.1.53.Escape character is '^]'.Login: usernamePassword: FTOS>

  • 14 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Multiple Configuration Users

    When a user enters the CONFIGURATION mode and another user(s) is already in that configuration mode, FTOS generates an alert warning message similar to the following:

    Figure 2-2. Configuration Mode User Alert

    When another user enters the CONFIGURATION mode, FTOS sends a message similar to the following, where the user in this case is “admin” on vty2:

    % Warning: User "admin" on line vty2 "172.16.1.210" is in configuration

    Navigating the Command Line InterfaceThe Command Line Interface (CLI) prompt displayed by FTOS is comprised of:

    • “hostname”— the initial part of the prompt, “FTOS” by default. You can change it with the hostname command, as described in hostname.

    • The second part of the prompt, reflecting the current CLI mode, as shown in Table 2-1.

    The CLI prompt changes as you move up and down the levels of the command structure. Table 2-1 lists the prompts and their corresponding command levels, called modes. Starting with the CONFIGURATION mode, the command prompt adds modifiers to further identify the mode. The command modes are explained in Command Modes.

    FTOS#conf

    % Warning: The following users are currently configuring the system:

    User "" on line console0 User "admin" on line vty0 ( 123.12.1.123 ) User "admin" on line vty1 ( 123.12.1.123 ) User "Irene" on line vty3 ( 123.12.1.321 )

    FTOS#conf

    Note: Some of the following modes are not available on C-Series or S-Series.

    Table 2-1. Command Prompt and Corresponding Command Mode

    Prompt CLI Command Mode

    FTOS> EXEC

    FTOS# EXEC Privilege

    FTOS(conf)# CONFIGURATION

  • CLI Basics | 15

    Obtaining HelpAs soon as you are in a command mode there are several ways to access help.

    • To obtain a list of keywords at any command mode, do the following: — Enter a ? at the prompt or after a keyword. There must always be a space before the ?.

    • To obtain a list of keywords with a brief functional description, do the following:— Enter help at the prompt.

    • To obtain a list of available options, do the following:

    FTOS(conf-if)#FTOS(conf-if-gi-0/0)#FTOS(conf-if-te-0/0)#FTOS(conf-if-lo-0)#FTOS(conf-if-nu-0)#FTOS(conf-if-po-0)#FTOS(conf-if-vl-0)#FTOS(conf-if-so-0/0)#FTOS(conf-if-ma-0/0)#FTOS(conf-if-range)#

    INTERFACE

    FTOS(config-ext-nacl)#FTOS(config-std-nacl)#

    IP ACCESS LIST

    FTOS(config-line-aux)#FTOS(config-line-console)#FTOS(config-line-vty)#

    LINE

    FTOS(config-ext-macl)#FTOS(config-std-macl)#

    MAC ACCESS LIST

    FTOS(config-mon-sess)# MONITOR SESSION

    FTOS(config-span)# STP

    FTOS(config-mstp)# MULTIPLE SPANNING TREE

    FTOS(config-pvst)# Per-VLAN SPANNING TREE Plus

    FTOS(config-rstp)# RAPID SPANNING TREE

    FTOS(config-gvrp)# PROTOCOL GVRP

    FTOS(config-route-map)# ROUTE-MAP

    FTOS(conf-nprefixl)# PREFIX-LIST

    FTOS(conf-router_rip)# ROUTER RIP

    FTOS(conf-redirect-list)# REDIRECT

    FTOS(conf-router_bgp)# ROUTER BGP

    FTOS(conf-router_ospf)# ROUTER OSPF

    FTOS(conf-router_isis)# ROUTER ISIS

    FTOS(conf-trace-acl)# TRACE-LIST

    Table 2-1. Command Prompt and Corresponding Command Mode

    Prompt CLI Command Mode

  • 16 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om — Type a keyword followed by a space and a ?

    • Type a partial keyword followed by a ? — A display of keywords beginning with the partial keyword is listed.

    Figure 2-3 illustrates the results of entering ip ? at the prompt.

    Figure 2-3. Partial Keyword Example

    When entering commands, you can take advantage of the following timesaving features:

    • The commands are not case sensitive.• You can enter partial (truncated) command keywords. For example, you can enter int gig int

    interface for the interface gigabitethernet interface command.• Use the TAB key to complete keywords in commands. • Use the up arrow key to display the last enabled command.• Use either the Backspace key or the Delete key to erase the previous character.

    FTOS(conf)#ip ?access-list Named access-list as-path BGP autonomous system path filter community-list Add a community list entry domain-list Domain name to complete unqualified host namedomain-lookup Enable IP Domain Name System hostname translationdomain-name Define the default domain name fib FIB configuration commands ftp FTP configuration commands host Add an entry to the ip hostname table max-frag-count Max. fragmented packets allowed in IP re-assemblymulticast-routing Enable IP multicast forwarding name-server Specify addess of name server to use pim Protocol Independent Multicast prefix-list Build a prefix list radius Interface configuration for RADIUS redirect-list Named redirect-list route Establish static routes scp SCP configuration commands source-route Process packets with source routing header optionsssh SSH configuration commands tacacs Interface configuration for TACACS+ telnet Specify telnet options tftp TFTP configuration commands trace-group Named trace-list trace-list Named trace-list FTOS(conf)#ip

  • CLI Basics | 17

    Use the left and right arrow keys to navigate left or right in the FTOS command line. Table 2-2 defines the key combinations valid at the FTOS command line.

    Using the Keyword NoTo disable, delete, or return to default values, use the no form of the commands. For most commands, if you type the keyword no in front of the command, you will disable that command or delete it from the running configuration. In this document, the no form of the command is discussed in the Command Syntax portion of the command description.

    Filtering show CommandsYou can filter the display output of a show command to find specific information, to display certain information only, or to begin the command output at the first instance of a regular expression or phrase.

    When you execute a show command, followed by a pipe ( | ) and one of the parameters listed below and a regular expression, the resulting output either excludes or includes those parameters, as defined by the parameter:

    • display — display additional configuration information

    Table 2-2. Short-cut Keys and their Actions

    Key Combination Action

    CNTL-A Moves the cursor to the beginning of the command line.

    CNTL-B Moves the cursor back one character.

    CNTL-D Deletes character at cursor.

    CNTL-E Moves the cursor to the end of the line.

    CNTL-F Moves the cursor forward one character.

    CNTL-I Completes a keyword.

    CNTL-K Deletes all characters from the cursor to the end of the command line.

    CNTL-L Re-enters the previous command.

    CNTL-N Return to more recent commands in the history buffer after recalling commands with Ctrl-P or the up arrow key

    CNTL-P Recalls commands, beginning with the last command

    CNTL-R Re-enters the previous command.

    CNTL-U Deletes the line.

    CNTL-W Deletes the previous word.

    CNTL-X Deletes the line.

    CNTL-Z Ends continuous scrolling of command outputs.

    Esc B Moves the cursor back one word.

    Esc F Moves the cursor forward one word.

    Esc D Deletes all characters from the cursor to the end of the word.

  • 18 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om • except— display only text that does not match the pattern (or regular expression)

    • find — search for the first occurrence of a pattern • grep — display text that matches a pattern• no-more — do not paginate the display output • save - copy output to a file for future use

    The grep command option has an ignore-case sub-option that makes the search case-insensitive. For example, the commands:

    • show run | grep Ethernet would return a search result with instances containing a capitalized “Ethernet,” such as interface GigabitEthernet 0/0.

    • show run | grep ethernet would not return the search result, above, because it only searches for instances containing a non-capitalized “ethernet.”

    Executing the command show run | grep Ethernet ignore-case would return instances containing both “Ethernet” and “ethernet.”

    Displaying All OutputTo display the output all at once (not one screen at a time), use the no-more after the pipe. This is similar to the terminal length screen-length command except that the no-more option affects the output of just the specified command.For example:

    FTOS#show running-config|no-more

    Filtering Command Output Multiple TimesYou can filter a single command output multiple times. Place the save option as the last filter. For example:

    FTOS# command | grep regular-expression | except regular-expression | grep other-regular-expression | find regular-expression | no-more | save

    Command ModesTo navigate to various CLI modes, you need to use specific commands to launch each mode. Navigation to these modes is discussed in the following sections.

    Note: FTOS accepts a space before or after the pipe, no space before or after the pipe, or any combination. For example:FTOS#command | grep gigabit |except regular-expression | find regular-expression

    Note: Some of the following modes are not available on C-Series or S-Series.

  • CLI Basics | 19

    EXEC Mode When you initially log in to the switch, by default, you are logged into the EXEC mode. This mode allows you to view settings and to enter the EXEC Privilege mode to configure the device. While you are in the EXEC mode, the > prompt is displayed following the “hostname” prompt, as described above. which is “FTOS” by default. You can change it with the hostname command. See the command hostname. Each mode prompt is preceded by the hostname.

    EXEC Privilege Mode The enable command accesses the EXEC Privilege mode. If an administrator has configured an “Enable” password, you will be prompted to enter it here.

    The EXEC Privilege mode allows you to access all commands accessible in EXEC mode, plus other commands, such as to clear ARP entries and IP addresses. In addition, you can access the CONFIGURATION mode to configure interfaces, routes, and protocols on the switch. While you are logged in to the EXEC Privilege mode, the # prompt is displayed.

    CONFIGURATION ModeIn the EXEC Privilege mode, use the configure command to enter the CONFIGURATION mode and configure routing protocols and access interfaces.

    To enter the CONFIGURATION mode:

    1. Verify that you are logged in to the EXEC Privilege mode.2. Enter the configure command. The prompt changes to include (conf).

    From this mode, you can enter INTERFACE by using the interface command.

    INTERFACE ModeUse the INTERFACE mode to configure interfaces or IP services on those interfaces. An interface can be physical (for example, a Gigabit Ethernet port) or virtual (for example, the Null interface).

    To enter INTERFACE mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the interface command followed by an interface type and interface number that is available

    on the switch. 3. The prompt changes to include the designated interface and slot/port number, as outlined in

    Table 2-3.

    Table 2-3. Interface prompts

    Prompt Interface Type

    FTOS(conf-if)# INTERFACE mode

    FTOS(conf-if-gi-0/0)# Gigabit Ethernet interface followed by slot/port information

    FTOS(conf-if-te-0/0)# Ten Gigabit Ethernet interface followed by slot/port information

    FTOS(conf-if-lo-0)# Loopback interface number.

  • 20 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om

    LINE ModeUse the LINE mode to configure console or virtual terminal parameters.

    To enter LINE mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the line command. You must include the keywords console or vty and their line number

    available on the switch.The prompt changes to include (config-line-console) or (config-line-vty).

    You can exit this mode by using the exit command.

    TRACE-LIST ModeWhen in the CONFIGURATION mode, use the trace-list command to enter the TRACE-LIST mode and configure a Trace list.

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the ip trace-list command. You must include the name of the Trace list. The prompt

    changes to include (conf-trace-acl).

    You can exit this mode by using the exit command.

    MAC ACCESS LIST ModeWhile in the CONFIGURATION mode, use the mac access-list standard or mac access-list extended command to enter the MAC ACCESS LIST mode and configure either standard or extended access control lists (ACL).

    To enter MAC ACCESS LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Use the mac access-list standard or mac access-list extended command. You must include

    a name for the ACL.The prompt changes to include (conf-std-macl) or (conf-ext-macl).

    You can return to the CONFIGURATION mode by entering the exit command.

    FTOS(conf-if-nu-0)# Null Interface followed by zero

    FTOS(conf-if-po-0)# Port-channel interface number

    FTOS(conf-if-vl-0)# VLAN Interface followed by VLAN number (range 1 to 4094)

    FTOS(conf-if-so-0/0)# SONET interface followed by slot/port information.

    FTOS(conf-if-ma-0/0)# Management Ethernet interface followed by slot/port information

    FTOS(conf-if-range)# Designated interface range (used for bulk configuration; see interface range).

    Table 2-3. Interface prompts (continued)

    Prompt Interface Type

  • CLI Basics | 21

    IP ACCESS LIST ModeWhile in the CONFIGURATION mode, use the ip access-list standard or ip access-list extended command to enter the IP ACCESS LIST mode and configure either standard or extended access control lists (ACL).

    To enter IP ACCESS LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Use the ip access-list standard or ip access-list extended command. You must include a

    name for the ACL.The prompt changes to include (conf-std-nacl) or (conf-ext-nacl).

    You can return to the CONFIGURATION mode by entering the exit command.

    ROUTE-MAP ModeWhile in the CONFIGURATION mode, use the route-map command to enter the ROUTE-MAP mode and configure a route map.

    To enter ROUTE-MAP mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Use the route-map map-name [permit | deny] [sequence-number] command. The prompt

    changes to include (route-map).

    You can return to the CONFIGURATION mode by entering the exit command.

    PREFIX-LIST ModeWhile in the CONFIGURATION mode, use the ip prefix-list command to enter the PREFIX-LIST mode and configure a prefix list.

    To enter PREFIX-LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the ip prefix-list command. You must include a name for the prefix list.The prompt changes

    to include (conf-nprefixl).

    You can return to the CONFIGURATION mode by entering the exit command.

    AS-PATH ACL ModeUse the AS-PATH ACL mode to configure an AS-PATH Access Control List (ACL) on the E-Series. See Chapter 7, Access Control Lists (ACL).

    To enter AS-PATH ACL mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the ip as-path access-list command. You must include a name for the AS-PATH ACL.The

    prompt changes to include (config-as-path).

    You can return to the CONFIGURATION mode by entering the exit command.

  • 22 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om IP COMMUNITY LIST Mode

    Use the IP COMMUNITY LIST mode to configure an IP Community ACL on the E-Series. See Chapter 7, Access Control Lists (ACL).

    To enter IP COMMUNITY LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Enter the ip community-list command. You must include a name for the Community list.The

    prompt changes to include (config-community-list).

    You can return to the CONFIGURATION mode by entering the exit command.

    REDIRECT-LIST ModeTo enter REDIRECT-LIST mode:

    1. Verify that you are logged in to the CONFIGURATION mode.2. Use the ip redirect-list command. You must include a name for the Redirect-list.The prompt

    changes to include (conf-redirect-list).

    You can return to the CONFIGURATION mode by entering the exit command.

    SPANNING TREE ModeUse the STP mode to enable and configure the Spanning Tree protocol, as described in Chapter 42, Spanning Tree Protocol (STP).

    To enter STP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol spanning-tree stp-id command.

    You can return to the CONFIGURATION mode by entering the exit command.

    Per-VLAN SPANNING TREE Plus ModeUse PVST+ mode to enable and configure the Per-VLAN Spanning Tree (PVST+) protocol, as described in Chapter 31, Per-VLAN Spanning Tree plus (PVST+).

    To enter PVST+ mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol spanning-tree pvst command.

    You can return to the CONFIGURATION mode by entering the exit command.

    Note: The protocol is PVST+, but the plus sign is dropped at the CLI prompt

  • CLI Basics | 23

    RAPID SPANNING TREE ModeUse PVST+ mode to enable and configure the RSTP protocol, as described in Chapter 35, Rapid Spanning Tree Protocol (RSTP).

    To enter RSTP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol spanning-tree rstp command.

    You can return to the CONFIGURATION mode by entering the exit command.

    MULTIPLE SPANNING TREE ModeUse MULTIPLE SPANNING TREE mode to enable and configure the Multiple Spanning Tree protocol, as described in Chapter 23, Multiple Spanning Tree Protocol (MSTP).

    To enter MULTIPLE SPANNING TREE mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol spanning-tree mstp command.

    You can return to the CONFIGURATION mode by entering the exit command.

    PROTOCOL GVRP ModeUse the PROTOCOL GVRP mode to enable and configure GARP VLAN Registration Protocol (GVRP), as described in Chapter 13, GARP VLAN Registration (GVRP).

    To enter PROTOCOL GVRP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the protocol gvrp command syntax.

    You can return to the CONFIGURATION mode by entering the exit command.

    ROUTER OSPF ModeUse the ROUTER OSPF mode to configure OSPF, as described in Chapter 26, Open Shortest Path First (OSPFv2 and OSPFv3).

    To enter ROUTER OSPF mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Use the router ospf {process-id} command.The prompt changes to include (conf-rout-

    er_ospf-id).

    You can switch to the INTERFACE mode by using the interface command or you can switch to the ROUTER RIP mode by using the router rip command.

  • 24 | CLI Basics

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om ROUTER RIP Mode

    Use the ROUTER RIP mode to configure RIP on the C-Series or E-Series, as described in Chapter 33, Router Information Protocol (RIP).

    To enter ROUTER RIP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the router rip command.The prompt changes to include (conf-router_rip).

    You can switch to the INTERFACE mode by using the interface command or you can switch to the ROUTER OSPF mode by using the router ospf command.

    ROUTER BGP ModeUse the ROUTER BGP mode to configure BGP on the C-Series or E-Series, as described in Chapter 8, Border Gateway Protocol IPv4(BGPv4).

    To enter ROUTER BGP mode:

    1. Verify that you are logged into the CONFIGURATION mode.2. Enter the router bgp as-number command.The prompt changes to include (conf-router_bgp).

    You can return to the CONFIGURATION mode by entering the exit command.

    Determining the Chassis ModeThe chassis mode in FTOS determines which hardware is being supported in an E-Series chassis. The chassis mode is programmed into an EEPROM on the backplane of the chassis and the change takes place only after the chassis is rebooted. Configuring the appropriate chassis mode enables the system to use all the ports on the card and recognize all software features.

  • File Management | 25

    3File Management

    Overview

    This chapter contains commands needed to manage the configuration files and includes other file management commands found in FTOS.

    Basic File Management CommandsThe commands included in this chapter are:

    • boot config• boot host • boot network• boot system (S55)• boot system gateway• cd• change bootflash-image• copy• copy (Streamline Upgrade)• copy running-config startup-config• delete• dir• download alt-boot-image• download alt-full-image• download alt-system-image• format (C-Series and E-Series)• format flash (S-Series)• logging coredump• logging coredump server• pwd• rename• restore fpga-image• restore fpga-image• show boot system• show bootvar• show file

  • 26 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om • show file-systems

    • show linecard• show os-version• show running-config• show sfm• show startup-config• show version• upgrade (E-Series version)• upgrade (C-Series version)• upgrade (S-Series management unit)• upgrade fpga-image (E-Series)• upgrade fpga-image (C-Series)• upgrade fpga-image (S55)

    boot configce Set the location and name of the configuration file that is loaded at system start-up (or reload) instead

    of the default startup-configuration.

    Syntax boot config {remote-first | rpm0 file-url | rpm1 file-url}

    To return to the default setting, enter no boot config {remote-first | rpm0 | rpm1}.

    Parameters

    Defaults Not configured.

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (copy running-config startup-config or write).

    Dell Networking strongly recommends using local files for configuration (RPM0 or RPM1 flash or slot0).

    remote-first Enter the keywords remote-first to attempt to load the boot configuration files from a remote location.

    rpm0 Enter the keywords rpm0 first to specify the local boot configuration file for RPM 0.rpm1 Enter the keywords rpm1 first to specify the local boot configuration file for RPM 1.file-url Enter the location information:

    • For a file on the internal Flash, enter flash:// followed by the filename.• For a file on the external Flash, enter slot0:// followed by the filename.

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

  • File Management | 27

    When you specify a file as the boot config file, it is listed in the boot variables (bootvar) as LOCAL CONFIG FILE. If you do not specify a boot config file, then the startup-configuration is used, although the bootvar shows LOCAL CONFIG FILE = variable does not exist. When you specify a boot config file, the switch reloads with that config file, rather than the startup-config. Note that if you specify a local config file which is not present in the specified location, then the startup-configuration is loaded.

    The write memory command always saves the running-configuration to the file labeled startup-configuration. When using a LOCAL CONFIG FILE other than the startup-config, use the copy command to save any running-configuration changes to that local file.

    Output for show bootvar with no boot configuration configured

    Output for show bootvar with boot configuration configured

    RelatedCommands

    boot hostc e Set the location of the configuration file from a remote host.

    Syntax boot host {primary | secondary} remote-url

    To return to the default settings, enter no boot host {primary | secondary} command.

    Parameters

    FTOS#show bootvarPRIMARY IMAGE FILE = flash://FTOS-EF-8.2.1.0.binSECONDARY IMAGE FILE = flash://FTOS-EF-7.6.1.0.binDEFAULT IMAGE FILE = flash://FTOS-EF-7.5.1.0.binLOCAL CONFIG FILE = variable does not existPRIMARY HOST CONFIG FILE = variable does not existSECONDARY HOST CONFIG FILE = variable does not existPRIMARY NETWORK CONFIG FILE = variable does not existSECONDARY NETWORK CONFIG FILE = variable does not existCURRENT IMAGE FILE = flash://FTOS-EF-8.2.1.0.binCURRENT CONFIG FILE 1 = flash://startup-configCURRENT CONFIG FILE 2 = variable does not existCONFIG LOAD PREFERENCE = local firstBOOT INTERFACE GATEWAY IP ADDRESS = variable does not exist

    FTOS#show bootvarPRIMARY IMAGE FILE = flash://FTOS-EF-8.2.1.0.binSECONDARY IMAGE FILE = flash://FTOS-EF-7.6.1.0.binDEFAULT IMAGE FILE = flash://FTOS-EF-7.5.1.0.binLOCAL CONFIG FILE = variable does not existPRIMARY HOST CONFIG FILE = variable does not existSECONDARY HOST CONFIG FILE = variable does not existPRIMARY NETWORK CONFIG FILE = variable does not existSECONDARY NETWORK CONFIG FILE = variable does not existCURRENT IMAGE FILE = flash://FTOS-EF-8.2.1.0.binCURRENT CONFIG FILE 1 = flash://CustomerA.cfgCURRENT CONFIG FILE 2 = variable does not existCONFIG LOAD PREFERENCE = local firstBOOT INTERFACE GATEWAY IP ADDRESS = variable does not exist

    show bootvar Display the variable settings for the E-Series boot parameters.

    primary Enter the keywords primary to attempt to load the primary host configuration files.

  • 28 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om

    Defaults Not configured.

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (using the copy command).

    RelatedCommands

    boot networkc e Set the location of the configuration file in a remote network.

    Syntax boot network {primary | secondary} remote-url

    To return to the default settings, enter no boot network {primary | secondary} command.

    Parameters

    Defaults None

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (using the copy command).

    RelatedCommands

    secondary Enter the keywords secondary to attempt to load the secondary host configuration files.remote-url Enter the following location keywords and information:

    • For a file on an FTP server, enter ftp://user:password@hostip/filepath• For a file on a TFTP server, enter tftp://hostip/filepath

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    show bootvar Display the variable settings for the E-Series boot parameters.

    primary Enter the keywords primary to attempt to load the primary network configuration files.secondary Enter the keywords secondary to attempt to load the secondary network configuration

    files.

    remote-url Enter the following location keywords and information:• For a file on an FTP server, enter ftp://user:password@hostip/filepath• For a file on a TFTP server, enter tftp://hostip/filepath

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    show bootvar Display the variable settings for the E-Series boot parameters.

  • File Management | 29

    boot system (C-Series and E-Series)c e Tell the system where to access the FTOS image used to boot the system.

    Syntax boot system {rpm0 | rpm1} (default | primary | secondary} file-url

    To return to the default boot sequence, use the no boot system {rpm0 | rpm1} {primary | secondary} command.

    Parameters

    Defaults Not configured.

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (using the copy command) and reload system.

    RelatedCommands

    boot system (S55)Tell the system where to access the FTOS image used to boot the system.

    Syntax boot system {gateway ip address| stack-unit [0-11 | all] [default | primary {system {A: | B:} | tftp: | | secondary]}To return to the default boot sequence, use the no boot system command.

    rpm0 Enter the keyword rpm0 to configure boot parameters for RPM0.rpm1 Enter the keyword rpm1 to configure boot parameters for RPM1.default After entering rpm0 or rpm1, enter the keyword default to specify the parameters to be

    used if those specified by primary or secondary fail. The default location should always be the internal flash device (flash:), so that you can be sure that a verified image is available there.

    primary After entering rpm0 or rpm1, enter the keyword primary to configure the boot parameters used in the first attempt to boot FTOS.

    secondary After entering rpm0 or rpm1, enter the keyword secondary to configure boot parameters used if the primary operating system boot selection is not available.

    file-url To boot from a file:• on the internal Flash, enter flash:// followed by the filename.• on an FTP server, enter ftp://user:password@hostip/filepath• on the external Flash, enter slot0:// followed by the filename.• on a TFTP server, enter tftp://hostip/filepath

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    change bootflash-image Change the primary, secondary, or default boot image configuration.

    boot system gateway Specify the IP address of the default next-hop gateway for the management subnet.

  • 30 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Parameters

    Defaults Not configured.

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    To display these changes in the show bootvar command output, you must save the running configuration to the startup configuration (using the copy command) and reload system.

    RelatedCommands

    boot system gatewayc e Specify the IP address of the default next-hop gateway for the management subnet.

    Syntax boot system gateway ip-address

    To delete a gateway configuration, enter no boot system gateway.

    Parameters

    Command Modes CONFIGURATION

    UsageInformation

    Saving the address to the startup configuration file preserves the address in NVRAM in case the startup configuration file is deleted.

    CommandHistory

    RelatedCommands

    gateway Enter the IP address of the default next-hop gateway for the management subnetstack-unit Enter the stack-unit number for the master switch.ip-address Enter an IP address in dotted decimal format.

    0-11, all Stack-unit number

    default Enter the default keyword to use the primary FTOS image.primary Enter the primary keyword to use the primary FTOS image.secondary Enter the secondary keyword to use the primary FTOS image.tftp: Enter TFTP: to retrieve the image from a TFTP server.

    tftp://hostip/filepath

    A: | B: Enter A: or B: to boot one of the system partitions.

    Version 8.3.5.0 Introduced on the S55

    boot system gateway Specify the IP address of the default next-hop gateway for the management subnet.

    ip-address Enter an IP address in dotted decimal format.

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    change bootflash-image Change the primary, secondary, or default boot image configuration.

  • File Management | 31

    cd c e s Change to a different working directory.

    Syntax cd directory

    Parameters

    Command Modes EXEC Privilege

    CommandHistory

    change bootflash-imagec e Change boot flash image from which to boot.

    Syntax change bootflash-image {cp | linecard linecard-slot | rp}

    Parameters

    Defaults Not configured.

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    A system message appears stating that the bootflash image has been changed. You must reload the system before the system can switch to the new bootflash image.

    copyc e s Copy one file to another location.

    Syntax copy source-file-url destination-file-url

    directory (OPTONAL) Enter one of the following:• flash: (internal Flash) or any sub-directory• slot0: (external Flash) or any sub-directory (C-Series and E-Series only)

    Version 7.6.1.0 Introduced on S-Series

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    cp Enter the keyword cp to change the bootflash image on the Control Processor on the RPM.

    linecard linecard-slot Enter the keyword linecard followed by the slot number to change the bootflash image on a specific line card.C-Series Range: 0-7 E-Series Range: 0 to 13 on the E1200; 0 on 6 on the E600, and 0 to 5 on the E300.

    rp Enter the keyword rp to change the bootflash image on the RPM Route Processor.

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

  • 32 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Parameters

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    FTOS supports a maximum of 100 files, at the root directory level, on both the internal and external Flash.

    The usbflash and rpm0usbflash commands are supported on E-Series ExaScale platform only. Refer to the FTOS Release Notes for a list of approved USB vendors.

    When copying a file to a remote location (for example, using Secure Copy (SCP)), enter only the keywords and FTOS prompts you for the rest of the information.

    For example, when using SCP, you can enter copy running-config scp: The running-config is the source, and the target is specified in the ensuing prompts. FTOS prompts you to enter any required information, as needed for the named destination—remote destination, destination filename, user ID and password, etc.

    When you use the copy running-config startup-config command to copy the running configuration (the startup configuration file amended by any configuration changes made since the system was started) to the startup configuration file, FTOS creates a backup file on the internal flash of the startup configuration.

    FTOS supports copying the running-configuration to a TFTP server or to an FTP server:

    file-url Enter the following location keywords and information:• To copy a file from the internal FLASH, enter flash:// followed by the filename.• To copy a file on an FTP server, enter ftp://user:password@hostip/filepath• To copy a file from the internal FLASH on RPM0, enter rpm0flash://filepath• To copy a file from the external FLASH on RPM0, enter rpm0slot0://filepath• To copy a file from the internal FLASH on RPM1, enter rpm1flash://filepath• To copy a file from the external FLASH on RPM1, enter rpm1slot0://filepath• To copy the running configuration, enter the keyword running-config.• To copy the startup configuration, enter the keyword startup-config.• To copy using Secure Copy (SCP), enter the keyword scp: (If scp: is entered in the

    source position, then enter the target URL; If scp: is entered in the target position, first enter the source URL; see below for examples.)

    • To copy a file on the external FLASH, enter slot0:// followed by the filename.• To copy a file on a TFTP server, enter tftp://hostip/filepathExaScale only• To copy a file from a USB drive on RPM0, enter rpm0usbflash://filepathExaScale and S55• To copy a file from an external USB drive, enter usbflash://filepath

    Version 8.3.5.0 Introduced on the S55.

    Version 8.2.1.0 Added usbflash and rpm0usbflash commands on E-Series ExaScaleVersion 7.6.1.0 Introduced on S-Series and added SSH port number to SCP prompt sequence on all

    systems.

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

  • File Management | 33

    copy running-config tftp:

    copy running-config ftp:

    Command Example: copy running-config scp:

    In this example — copy scp: flash: — specifying SCP in the first position indicates that the target is to be specified in the ensuing prompts. Entering flash: in the second position means that the target is the internal Flash. In this example the source is on a secure server running SSH, so the user is prompted for the UDP port of the SSH server on the remote host.

    Using scp to copy from an SSH Server

    RelatedCommands

    copy (Streamline Upgrade)c e Copy a system image to a local file and update the boot profile.

    Syntax copy source-url target-url [boot-image [synchronize-rpm [external]]]

    Parameters

    Defaults No default behavior

    Command Modes CONFIGURATION

    CommandHistory

    FTOS#copy running-config scp:/Address or name of remote host []: 10.10.10.1Destination file name [startup-config]? old_runningUser name to login remote host? homePassword to login remote host? home

    FTOS#copy scp: flash:Address or name of remote host []: 10.11.199.134Port number of the server [22]: 99Source file name []: test.cfgUser name to login remote host: adminPassword to login remote host: Destination file name [test.cfg]: test1.cfg

    cd Change working directory.

    source-url Enter the source file in url format. The source file is a valid Dell Networking release image. Image validation is automatic.

    target-url Enter the local target file in url format.

    boot-image Enter the keyword boot-image to designate this copy command as a streamline update.

    synchronize-rpm Enter the keyword synchronize-rpm to copy the new image file to the peer RPM.

    external Enter the keyword external to designate the target device on the peer RPM as external flash (instead of the default internal flash).Default: Internal Flash

    Version 7.5.1.0 Introduced on C-Series

    Version 6.1.1.0 Introduced

  • 34 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Usage

    InformationIn this streamline copy command, the source image is copied to the primary RPM and then, if specified, to the standby RPM. After the copy is complete, the new image file path on each RPM is automatically configured as the primary image path for the next boot. The current system image (the one from which the RPM booted) is automatically configured as the secondary image path.

    copy running-config startup-config c e

    Copy running configuration to the startup configuration.

    Syntax copy running-config startup-config {duplicate}

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    This command is useful for quickly making a changed configuration on one chassis available on external flash in order to move it to another chassis.

    When you use the copy running-config startup-config duplicate command to copy the running configuration to the startup configuration, FTOS creates a backup file on the internal flash of the startup configuration.

    deletec e s Delete a file from the flash. Once deleted, files cannot be restored.

    Syntax delete flash-url [no-confirm]

    Parameters

    Command Modes EXEC Privilege

    CommandHistory

    Note: The keywords boot-image, synchronize-rpm, and external can be used on the Primary RPM only.

    Version 8.3.5.0 Introduced on S55.

    Version 7.5.1.0 Introduced on C-Series

    Version 6.3.1.0 Introduced

    flash-url Enter the following location and keywords:• For a file or directory on the internal Flash, enter flash:// followed by the filename or

    directory name.• For a file or directory on the external Flash, enter slot0:// followed by the filename or

    directory name.

    no-confirm (OPTIONAL) Enter the keyword no-confirm to specify that FTOS does not require user input for each file prior to deletion.

    Version 7.6.1.0 Introduced on S-Series

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

  • File Management | 35

    dirc e s Display the files in a filesystem. The default is the current directory.

    Syntax dir [filename | directory name:]

    Parameters

    Command Modes EXEC Privilege

    CommandHistory

    Example Command Example dir for the Internal Flash

    RelatedCommands

    download alt-boot-imagec e Download an alternate boot image to the chassis.

    Syntax download alt-boot-image file-url

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade command.

    For software upgrade details, see the FTOS Release Notes.

    RelatedCommands

    filename | directory name: (OPTIONAL) Enter one of the following:• For a file or directory on the internal Flash, enter flash://

    followed by the filename or directory name.• For a file or directory on the external Flash, enter slot0://

    followed by the filename or directory name:

    Version 8.3.5.0 Introduced on the S55.

    Version 7.6.1.0 Introduced on S-Series

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    FTOS#dir Directory of flash:

    1 -rwx 6478482 May 13 101 16:54:34 E1200.BIN

    flash: 64077824 bytes total (57454592 bytes free)FTOS#

    cd Change working directory.

    Version 7.7.1.0 Removed from E-Series and C-Series

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    upgrade (E-Series version) Upgrade the bootflash or boot selector versions.

    upgrade (C-Series version) Upgrade the bootflash or boot selector versions.

  • 36 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om download alt-full-image

    e Download an alternate FTOS image to the chassis.

    Syntax download alt-full-image file-url

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade command.

    For software upgrade details, see the FTOS Release Notes.

    RelatedCommands

    download alt-system-imagee Download an alternate system image (not the boot flash or boot selector image) to the chassis.

    Syntax download alt-system-image file-url

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    Starting with FTOS 7.7.1.0, the functions of this command are incorporated into the upgrade command.

    For software upgrade details, see the FTOS Release Notes.

    RelatedCommands

    format (C-Series and E-Series)ce Erase all existing files and reformat a filesystem. Once the filesystem is formatted, files cannot be

    restored.

    Syntax format filesystem: [dosFs1.0 | dosFs2.0]

    Parameters

    Version 7.7.1.0 Removed form E-Series

    Version 6.5.1.0 Introduced

    upgrade (E-Series version) Upgrade the bootflash or boot selector versions

    Version 7.7.1.0 Removed from E-Series

    Version 6.5.1.0 Introduced

    upgrade (E-Series version) Upgrade the bootflash or boot selector versions

    filesystem: Enter one of the following:• To reformat the internal Flash, enter flash:• To reformat the external Flash, enter slot0:

  • File Management | 37

    Default DOS 1.0 (dosFs1.0)

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    When you format flash:

    1 The startup-config is erased.2 All cacheboot data files are erased and you must reconfigure cacheboot to regain it.3 All generated SSH keys are erased and you must recreate them.4 All archived configuration files are erased.5 All trace logs, crash logs, core dumps, and call-home logs are erased.6 In-service Process patches are erased.

    After reformatting is complete, three empty directories are automatically created on flash: CRASH_LOG_DIR, TRACE_LOG_DIR and NVTRACE_LOG_DIR.

    Note: Version option is available on LC-ED-RPM only. LC-EE3-RPM, LC-EF-RPM, and LC-EF3-RPM supports DOS 2.0 only.

    RelatedCommands

    format flash (S-Series)s Erase all existing files and reformat the filesystem in the internal flash memory. Once the filesystem is

    formatted, files cannot be restored.

    Syntax format flash:

    Default flash memory

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    You must include the colon (:) when entering this command.

    Caution: This command deletes all files, including the startup configuration file. So, after executing this command, consider saving the running config as the startup config (use the write memory command or copy run start).

    dosFs1.0 Enter the keyword dosFs1.0 to format in DOS 1.0 (the default)dosFs2.0 Enter the keyword dosFs2.0 to format in DOS 2.0

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    show file Display contents of a text file in the local filesystem.

    show file-systems Display information about the file systems on the system.

    Version 7.8.1.0 Introduced on S-Series

  • 38 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Related

    Commands

    format flash (S55)Erase all existing files and reformat the filesystem in the internal flash memory or the USB drive. Once the filesystem is formatted, files cannot be restored.

    Syntax format [flash: | usbflash: ]

    Parameters

    Default flash memory

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    You must include the colon (:) when entering this command.

    Caution: This command deletes all files, including the startup configuration file. So, after executing this command, consider saving the running config as the startup config (use the write memory command or copy run start).

    logging coredumpc e s Enable coredump.

    Syntax logging coredump {cp | linecard {number | all} | rps | stack-unit {id | all}}

    Disable coredump using the command no logging coredump {cp | linecard {number | all} | rps}

    Parameters

    Defaults The kernel coredump is enabled by default for RP 1 and 2 on E-Series. The kernel coredump for CP and application coredump are disabled on all systems by default.

    Command Modes CONFIGURATION

    copy Copy the current configuration to either the startup-configuration file or the terminal.

    show file Display contents of a text file in the local filesystem.

    show file-systems Display information about the file systems on the system.

    flash: Reformat the filesystem in the internal flash memoryusbflash: Reformat the filesystem in the connected USB drive memory

    Version 8.3.5.0 Introduced on the S55.

    cp Enable coredump for the CP.linecard Enable coredump for a linecard.rps Enable coredump for RP 1 and 2.

    stack-unit Enable coredump for the stack-unit.Range: S55 0-11All other S-Series 0-7

  • File Management | 39

    CommandHistory

    UsageInformation

    The Kernel core dump can be large and may take up to 5 to 30 minutes to upload. FTOS does not overwrite application coredumps so you should delete them as necessary to conserve space on the flash; if the flash is out of memory, the coredump is aborted. On the S-Series, if the FTP server is not reachable, the application coredump is aborted. FTOS completes the coredump process and waits until the upload is complete before rebooting the system.

    RelatedCommands

    logging coredump serverc e s Designate a server to upload coredumps.

    Syntax logging coredump server address username name password [type] password

    Disable logging coredumps to a server using the command no logging coredump server address username name password [type] password

    Parameters

    Defaults Crash kernel files are uploaded to flash by default.

    Command Modes CONFIGURATION

    CommandHistory

    UsageInformation

    Since flash space may be limited, using this command ensures your entire crash kernel files are uploaded successfully and completely.

    RelatedCommands

    Version 8.3.5.0 Introduced on the S55.

    Version 7.7.1.0 Restructured command to accommodate coredumps for CP. Introduced on C-Series and S-Series

    Version 6.5.1.0 Application coredump naming convention enhanced to include application.

    Version 6.1.1.0 Introduced

    logging coredump server Designate a sever to upload kernel core-dumps.

    address Enter the server IP address in dotted decimal format (A.B.C.D) or hostname.

    name Enter a username to access the target server.

    type Enter the password type:• Enter 0 to enter an unencrypted password.• Enter 7 to enter a password that has already been encrypted using a Type

    7 hashing algorithm.

    password Enter a password to access the target server.

    Version 7.7.1.0 Restructured command to accommodate coredumps for CP. Introduced on C-Series and S-Series.

    Version 6.1.1.0 Introduced

    Note: You must disable logging coredump before you designate a new server destination for your coredumps.

    logging coredump Disable the kernel coredump

  • 40 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om pwd

    c e s Display the current working directory.

    Syntax pwd

    Command Modes EXEC Privilege

    CommandHistory

    Example Command Example: pwd

    RelatedCommands

    renameces Rename a file in the local file system.

    Syntax rename url url

    Parameters

    Command Modes EXEC Privilege

    CommandHistory

    restore factory-defaultsRestore factory defaults.

    Syntax restore factory-defaults stack-unit {0-11 | all} {clear-all | nvram}

    Parameters

    Version 8.3.5.0 Introduced on the S55.

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    FTOS#pwd flash: FTOS#

    cd Change directory.

    url Enter the following keywords and a filename:• For a file on the internal Flash, enter flash:// followed by the filename.• For a file on the external Flash, enter slot0:// followed by the filename.

    Version 8.3.5.0 Introduced on the S55.

    Version 7.6.1.0 Introduced on S-Series

    Version 7.5.1.0 Introduced on C-Series

    E-Series original Command

    factory-defaults Return the system to its factory default mode.

    0-11 Enter this keyword to restore only the mentioned stack-unit.

    all Enter this keyword to restore all units in the stack.

  • File Management | 41

    Command Modes EXEC Privilege

    CommandHistory

    UsageInformation

    Restoring factory defaults deletes the existing startup configuration and all persistent settings (stacking, fanout, etc.).

    Dell Networking recommends backing up the startup configuration before using this command.

    When restoring all units in a stack, all the units in the stack are placed into stand-alone mode.

    When restoring a single unit in a stack, that unit is placed in stand-alone mode. No other units in the stack are affected.

    When restoring units in stand-alone mode, the units remain in stand-alone mode after the restoration.

    After the restore is complete, the units power cycle immediately.

    Example Figure 3-1. restore factory-defaults (all units in a stack) Command Example

    clear-all Enter this keyword to reset the NvRAM and the system startup configuration.

    nvram Enter this keyword to reset the NvRAM only.

    Version 8.3.3.9 Introduced on the S60

    Version 8.3.5.5 Introduced on the S55

    Version 8.3.17.1 Supported on M I/O Aggregator

    Caution: There is no undo for this command.

    FTOS#restore factory-defaults stack-unit all clear-all

    *********************************************************************** * Warning - Restoring factory defaults will delete the existing * * startup-config and all persistent settings (stacking, fanout, etc.)* * All the units in the stack will be split into standalone units. * * After restoration the unit(s) will be powercycled immediately. * * Proceed with caution ! * ***********************************************************************

    Proceed with factory settings? Confirm [yes/no]:yes

    -- Restore status --Unit Nvram Config------------------------ 0 Success Success 1 Success Success 2 Success Success 3 Not present 4 Not present 5 Not present

    Power-cycling the unit(s).

    FTOS#

  • 42 | File Management

    ww

    w.d

    ell

    .co

    m |

    su

    pp

    ort

    .de

    ll.c

    om Figure 3-2. restore factory-defaults (single unit in a stack) Command Example

    Figure 3-3. restore factory-defaults (NvRAM only, all units in a stack) Command Example

    FTOS#restore factory-defaults stack-unit 0 clear-all

    *********************************************************************** * Warning - Restoring factory defaults will delete the existing * * startup-config and all persistent settings (stacking, fanout, etc.)* * After restoration the unit(s) will be powercycled immediately. * * Proceed with caution ! * ***********************************************************************

    Proceed with factory settings? Confirm [yes/no]:yes

    -- Restore status --Unit Nvram Config------------------------ 0 Success Success

    Power-cycling