delta a/c supply commercial fittings · length is measured to tap flange w1 d1 l1 connector end...
TRANSCRIPT
Y TY TEE TER TE
DELTA A/C SUPPLY COMMERCIAL FITTINGS
RE CE CER REAB E
BNY PY RT ST TAP
RO RDS2U RS STAP STR
RECTANGULAR ELBOW “RE”
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
WIDTH OUT “W2”
THROAT STRAIGHT IN “S1”
THROAT STRAIGHT OUT “S2”
TURNING VANES Y/ N
LINED Y/ N
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
WIDTH OUT “W2”
THROAT STRAIGHT IN “S1”
THROAT STRAIGHT OUT “S2”
TURNING VANES Y/ N
LINED Y/ N
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
WIDTH OUT “W2”
THROAT RADIUS “R1”
THROAT STRAIGHT IN “S1”
THROAT STRAIGHT OUT “S2”
ANGLE OF ELBOW “A1”
LINED Y / N
RADIUS BACK ELBOW W/ SQ THROAT “CER”
RADIUS ELBOW “CE”
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
WIDTH OUT “W2”
THROAT STRAIGHT IN “S1”
THROAT STRAIGHT OUT “S2”
LINED Y / N
RECTANGULAR ELBOW - ANGLE BACK “REAB”
DELTA A/C SUPPLY COMMERCIAL FITTINGS ORDER FORM
W1 D1
S1
S2
W2
END 2
END 1 END 1
W1 D1 S1
S2 END 2
W2
END 1
END 2
W1 D1
W2
S1
S2
R1
A1
90°
0° END 1
END 2
W1 D1 S1
S2
W2 45°
CONNECTOR END OPTIONS P=PLUG R=RAW F=FLANGE S/D= S/CLIP & DRIVE DM=DUCTMATE TI = TAP-IN LINER 1” = R4 1 1/2” = R6 2” = R8 PLEASE ALLOW DUCT SIZING TO INCLUDE INSULATION THICKNESS.
ELBOW W/SQUARE THROAT “E “
RECTANGULAR OFFSET “RO”
REDUCER “RDS2U”
RECTANGULAR TRANSITION “RS”
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
WIDTH OUT “W2”
ANGLE OF ELBOW “A1”
THROAT STRAIGHT IN “S1”
THROAT STRAIGHT OUT “S2”
LINED Y/ N
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
LENGTH “L1”
WIDTH OUT “W2”
DEPTH OUT “D2”
OFFSET “O1”
EXTRA STRAIGHT IN “S1”
EXTRA STRAIGHT OUT “S2”
LINED Y / N
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
LENGTH “L1”
WIDTH OUT “W2”
DEPTH OUT “D2”
EXTRA STRAIGHT IN “S1”
EXTRA STRAIGHT OUT “S2”
LINED Y / N
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
LENGTH “L1”
WIDTH OUT “W2”
DEPTH OUT “D2”
OFFSET “O1”
TOP DOWN OFFSET “TD1:
EXTRA STRAIGHT IN “S1”
EXTRA STRAIGHT OUT “S2”
LINED Y / N STRAIGHTS MUST BE GREATER THAN 0
STRAIGHTS ARE INCLUDED IN LENGTH
STRAIGHTS ARE INCLUDED IN OVERALL LENGTH TOP DOWN OFFSET ENTERD AS 0 MEANS TOP FLAT TOP DOWN OFFSET ENTERED AS A NEGATIVE MEANS TOP RISES TOP DOWN OFFSET ENTERED AS A POSITIVE MEANS TOP DROPS
DELTA A/C SUPPLY COMMERCIAL FITTINGS ORDER FORM
W1 D1 END 1
END 2
W2 A1
S1
S2
END 1 END 1 END 1
L1
W1
D1
S1
S2
W2
O1 W1 D1
W2 S2
S1
L1
END 2
W1
D1
L1 W2
D2
O1 S1
S2
END 2
TD1 D2
CONNECTOR END OPTIONS P=PLUG R=RAW F=FLANGE S/D= S/CLIP & DRIVE DM=DUCTMATE TI = TAP-IN LINER 1” = R4 1 1/2” = R6 2” = R8 PLEASE ALLOW DUCT SIZING TO INCLUDE INSULATION THICKNESS.
ID
GUAGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
LENGTH “L1”
ANGLE “A1”
THROAT STRAIGHT IN “S1”
LINED Y / N
SHOE TAP “STAP”
SQUARE TO ROUND “STR”
STANDARD ANGLE 45 DEGREES
OFFSET IS MEASURED FROM CENTER OF COLLAR O1 OFFSETS THE WIDTH O2 OFFSETS THE DEPTH S2 IS COLLAR LENGTH
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
WIDTH IN “W1”
DEPTH IN “D1”
DIAMETER OUT “D2”
OFFSET 1 “O1”
OFFSET 2 “O2”
LENGTH “L1”
EXTRA STRAIGHT IN “S1”
EXTRA STRAIGHT OUT “S2”
LINED Y / N
WYE BRANCH “Y”
T– WYE “TY”
DELTA A/C SUPPLY COMMERCIAL FITTINGS ORDER FORM
W1 D1
L1 S1
A1
W1 D1
END 1
END 2
END 1
END 2 D2
L1
S1
S2
- +
O1 O2
+ -
STANDARD ANGLE 45 DEGREES
D2
D1
D3
D2
ID GAUGE
QUANTITY
CONNECTOR END 1 M / F
CONNECTOR END 2 M / F
CONNECTOR END 3 M / F
DIAMETER 1 “D1”
DIAMETER 2 “D2”
DIAMETER 3 “D3”
ID GAUGE
QUANTITY
CONNECTOR END 1 M / F
CONNECTOR END 2 M / F
CONNECTOR END 3 M / F
DIAMETER 1 “D1”
DIAMETER 2 “D2”
DIAMETER 3 “D3”
D3
D1
STANDARD ANGLE 90 DEGREES
END 1
END 2
END 3
END 2
END 3
END 1
CONNECTOR END OPTIONS P=PLUG R=RAW F=FLANGE S/D= S/CLIP & DRIVE DM=DUCTMATE TI = TAP-IN LINER 1” = R4 1 1/2” = R6 2” = R8 PLEASE ALLOW DUCT SIZING TO INCLUDE INSULATION THICKNESS.
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
COMMECTOR END 3
WIDTH IN “W1”
DEPTH IN “D1”
WIDTH OUT-LEFT “W2”
WIDTH OUT-RIGHT “W3”
THROAT STRAIGHT IN “S1”
THROAT STRAIGHT –LEFT “S2”
THROAT STRAIGHT –RIGHT “S3”
TURNING VANES Y /N
LINED Y / N
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
CONNECTOR END 3
WIDTH IN “W1”
DEPTH IN “D1”
WIDTH OUT-LEFT “W2”
WIDTH OUT-RIGHT “W3”
THROAT STRAIGHT—IN “S1”
THROAT STRAIGHT –LEFT “S2”
THROAT STRAIGHT –RIGHT “S3”
TURNING VANES Y /N
LINED Y / N
RECTANGULAR TEE “TEE”
RADIUS TEE W/RECTANGULAR THROAT “TER”
DELTA A/C SUPPLY COMMERCIAL FITTINGS ORDER FORM
ID
GAUGE
QUANTITY
CONNECTOR END 1
CONNECTOR END 2
CONNECTOR END 3
WIDTH IN “W1”
DEPTH IN “D1”
WIDTH OUT-LEFT “W2”
WIDTH OUT-RIGHT “W3”
THROAT STRAIGHT IN “S1”
THROAT STRAIGHT –LEFT “S2”
THROAT STRAIGHT –RIGHT “S3”
THROAT RADIUS—LEFT “R1”
THROAT RADIUS—RIGHT “R2”
LINED Y / N
RADIUS TEE “TE”
BULL NOSE WYE “BNY”
END 1
END 2
END 3
W1
W2 W3
S1
S2
S3
D1
END 2
END 3
END 1 W1 D1
W2 W3
S1
S2
S3
END 1
END 2
END 3
W2
W3
W1 D1
S2
S3
S1
R1
R2
END 1
END 2
END 3
ID GAUGE
QUANTITY
CONNECTOR END 1 M / F
CONNECTOR END 2 M / F
CONNECTOR END 3 M / F
DIAMETER 1 “D1”
DIAMETER 2 “D2”
DIAMETER 3 “D3”
LINED Y / N
D1
D2
D3
CONNECTOR END OPTIONS P=PLUG R=RAW F=FLANGE S/D= S/CLIP & DRIVE DM=DUCTMATE TI = TAP-IN LINER 1” = R4 1 1/2” = R6 2” = R8 PLEASE ALLOW DUCT SIZING TO INCLUDE INSULATION THICKNESS.
PANT WYE “PY”
REGISTER TAP “RT”
SADDLE TAP “ST”
TAP– IN “TAP”
DELTA A/C SUPPLY COMMERCIAL FITTINGS ORDER FORM
ID GAUGE
QUANTITY
CONNECTOR END 1 M / F
CONNECTOR END 2 M / F
CONNECTOR END 3 M / F
DIAMETER 1 “D1”
DIAMETER 2 “D2”
DIAMETER 3 “D3”
STRAIGHT IN “S1”
LINED Y / N
S1
D1
D2 D3
ID GAUGE
QUANTITY
WIDTH IN “W1”
DEPTH IN “D1”
PIPE SIZE “P1”
LENGTH “L1”
FLANGE 1 “F1”
FLANGE 2 “F2”
LINED Y / N
W1 D1
F1
F2
P1
L1
ID GAUGE
QUANTITY
PIPE SIZE ‘”P1”
DIAMETER “D1”
LINED Y / N
P1
D1
ID GAUGE
QUANTITY
WIDTH IN “W1”
DEPTH IN “D1”
LENGTH “L1”
LINED Y / N
LENGTH IS MEASURED TO TAP FLANGE
W1 D1
L1
CONNECTOR END OPTIONS P=PLUG R=RAW F=FLANGE S/D= S/CLIP & DRIVE DM=DUCTMATE TI = TAP-IN LINER 1” = R4 1 1/2” = R6 2” = R8 PLEASE ALLOW DUCT SIZING TO INCLUDE INSULATION THICKNESS.