This report is issued under the rules of DANAK (Danish Accredi tation) and ILAC(International Laboratory Accreditation Cooperation) including its MRA (Mutual RecognitionArrangement) . Further information can be found at www.danak.dk and www.i lac.org.The report must not be reproduced, except in ful l , without the written approval of DELTA.
DELTA Test Report
Version m
TEST Reg. no. 19
Test for Marine Type Approval of Commander Utility RelayOutput Module, Commander Utility 24 I/O Interface Moduleand Searchlight Halogen 2000W network operated
Performed for Tranberg AS
DANAK-1911419
Project no.: A507381 Revision A
Page 1 of 46
including 5 annexes
24 June 2011
DANAK-1911419 Rev. ADELTA-A507381Page 2 of 46
RAS/lko
Title Test for Marine Type Approval of Commander UtilityRelay Output Module, Commander Utility 24 I/OInterface Module and Searchlight Halogen 2000Wnetwork operated
Test objects 1 pcs. Commander Utility Relay Output Module,Part no. 4500801
1 pcs. Commander Utility 24 I/O Interface Module,Part no. 4500802
1 pcs. Searchlight Halogen 2000W network operatedPart no. 2650415430
Detailed information is given in Chapter 2.
The test objects were received on 6 January 2011.
Report no. DANAK-1911419 Revision A
Project no. A507381
Test period 7 January - 31 May 2011
Client Tranberg ASStrandsvingen 6P.O.Box 80334003 StavangerNorge
Contact person Torstein RysstadE-mail: [email protected]
Manufacturer Tranberg AS
Specifications IEC 60945: Fourth edition, 2002 “Maritime navigationand radio communication equipment and systems -General requirements - Methods of testing and requiredtest results.”
Results No malfunctions were detected, other than malfunctionsat burst. The criteria for compliance are listed in Section3.2.
Test personnel Claus Momme ThomsenPeter Wolf FrandsenRoa SalmanPoul Nørgaard
DANAK-1911419 Rev. ADELTA-A507381Page 3 of 46
RAS/lko
Date 24 June 2011
Project manager
Henrik Funding Raun, B.Sc.E.E.DELTA
Responsible
Susanne Otto, B.Sc.E.E., B.Com (Org.)DELTA
This report replaces previously issued report DANAK-1911419 dated 10 June 2011.The changes in this report is:
Page 1, 2, 7 and 11: Name of test object (Searchlight Halogen) corrected
DANAK-1911419 Rev. ADELTA-A507381Page 4 of 46
RAS/lko
Table of contents
1. Summary of test 5
1.1 Test requirements 5
1.2 Conclusion 6
2. Test objects 7
2.1 Test objects 7
2.2 Auxiliary equipment 8
3. General test conditions 9
3.1 Test setup 9
3.2 Criteria for compliance 9
3.3 Functional test 9
3.4 Standard environment 10
4. Test and results 11
4.1 Test summary 11
4.2 Immunity to power supply failure 12
4.3 Extreme variation in power supplies 12
4.4 Immunity to power supply short-term variation 13
4.5 Extreme variation in power supplies 13
4.6 Excessive conditions - Reverse polarity 14
4.7 Excessive conditions - Excessive voltage 14
4.8 Immunity to electrostatic discharge 15
4.9 Immunity to radiated radiofrequencies 16
4.10 Immunity to conducted radio frequency disturbance 16
4.11 Immunity to fast transients on a.c. power, signal and control lines 17
4.12 Immunity to surges on a.c. power lines 18
4.13 Radiated emissions 19
4.14 Conducted emissions 20
Annex 1 List of instruments 21
Annex 2 Photos 23
Annex 3 Test record sheets - Radiated emissions 30
Annex 4 Test record sheets - Conducted emissions 35
Annex 5 Test setup and functional test procedure (from Client) (This annex is
informative and not part of the accredited report) 42
DANAK-1911419 Rev. ADELTA-A507381Page 5 of 46
RAS/lko
1. Summary of test
1.1 Test requirements
The following tests were carried out as agreed with the client.
Test Test method
Immunity to power supply failure IEC 60945:2002
Extreme variation in power supplies IEC 60945:2002
Immunity to power supply short-termvariation
IEC 60945:2002
Power supply variations - permanent IEC 60945:2002
Excessive conditions - Reverse polarity IEC 60945:2002
Excessive conditions - Excessive voltage IEC 60945:2002
Immunity to electrostatic discharge IEC 61000-4-2:2001
Immunity to radiated radiofrequencies IEC 61000-4-3:2006
Immunity to conducted radio frequencydisturbance
IEC 61000-4-6:2007
Immunity to fast transients on a.c. power,signal and control lines
IEC 61000-4-4:2004
Immunity to surges on a.c. power lines IEC 61000-4-5:2005
Radiated Emissions CISPR 16-2-3:2006
Conducted emissions CISPR16-2-1:2008
DANAK-1911419 Rev. ADELTA-A507381Page 6 of 46
RAS/lko
1.2 Conclusion
The test objects mentioned in this report meets the relevant requirements of the standard
stated below.
IEC 60945:2002
The test results relate only to the objects tested.
DANAK-1911419 Rev. ADELTA-A507381Page 7 of 46
RAS/lko
2. Test objects
2.1 Test objects
Test object 2.1.1
Name of test object Commander Utility Relay Output Module
Model / type -
Part no. 4500801
Serial no. Delta-1
Manufacturer Tranberg AS
Supply voltage 18-32 VDC
Comments -
Test object 2.1.2
Name of test object Commander Utility 24 I/O Interface Module
Model / type -
Part no. 4500802
Serial no. Delta-1
Manufacturer Tranberg AS
Supply voltage 18-32 VDC
Comments -
Test object 2.1.3
Name of test object Searchlight Halogen 2000W network operated
Model / type -
Part no. 2650415430
Serial no. Delta-1
Manufacturer Tranberg AS
Supply voltage 230 VAC
Comments -
DANAK-1911419 Rev. ADELTA-A507381Page 8 of 46
RAS/lko
2.2 Auxiliary equipment
Auxiliary equipment 2.2.1
Name of auxiliary equipment Searchlight Commander Series Control Panel
Model / type -
Part no. 2613381100
Serial no. 10335
Manufacturer Tranberg AS
Supply voltage 24 VDC
Comments -
DANAK-1911419 Rev. ADELTA-A507381Page 9 of 46
RAS/lko
3. General test conditions
3.1 Test setup
A description of the test setup is enclosed in Annex 5.
3.2 Criteria for compliance
No change of the actual operational states of the test object is allowed. However,
temporary change is allowed during the power supply failure test.
In addition, the following generic acceptance criteria for compliance were in force
during the EMC immunity testing:
Performance Criterion A: (For continuous phenomena): The EUT shall continue
to operate as intended during and after the test. No degradation of performance or
loss of function is allowed as defined in the relevant equipment standard and in
the technical specification published by the manufacturer.
Performance Criterion B: (For transient phenomena): The EUT shall continue to
operate as intended after the tests. No degradation of performance or loss of
function is allowed as defined in the technical specification published by the
manufacturer. During the test, degradation or loss of function or performance
which is self-recoverable is, however, allowed but no change of actual operating
state or stored data is allowed.
Performance Criterion C: Temporary degradation or loss of function or
performance is allowed during and after the test, provided the function is self-
recoverable, or can be restored by the operation of the controls as defined in the
relevant equipment standard and in the technical specification published by the
manufacturer.
3.3 Functional test
A functional test was performed before, during (if specified) and after each test. The
functional test was carried out in accordance with the functional test procedure provided
by the client.
The functional test procedure is given in Annex 55.
DANAK-1911419 Rev. ADELTA-A507381Page 10 of 46
RAS/lko
3.4 Standard environment
Normal environmental condition:
Temperature : 15 °C - 35 °C
Humidity : 25 %RH - 75 %RH
Air pressure : 86 kPa - 106 kPa (860 mbar - 1060 mbar)
Power supply voltage : Unom. ±3%
DANAK-1911419 Rev. ADELTA-A507381Page 11 of 46
RAS/lko
4. Test and results
4.1 Test summary
The following tests were carried out as agreed with the client.
Test name
Standard
Relay
Output
Module
4500801
Relay
output/Digital
input module
4500802
Searchlight
Halogen
2000W
Immunity to power
supply failure
60945
clause 10.8Passed Passed Passed
Extreme power supply
variation (AC)
60945
clause 5.2.2Passed
Immunity to power
supply short-term
variationfailure
60945
clause 10.7Passed
Extreme power supply
variation (DC)
60945
clause 5.2.2Passed Passed
Excessive conditions -
Reverse polarity
60945
clause 5.2.3Passed Passed
Excessive conditions -
Excessive voltage60945
clause 5.2.3
Passed
Immunity to electrostatic
discharge
60945
clause 10.9Passed Passed Passed
Immunity to radiated
radiofrquencies
60945
clause 10.4Passed Passed Passed
Immunity to conducted
radio frequency
disturbance
60945
clause 10.3Passed Passed Passed
Immunity to fast
transients on a.c. power,
signal and control lines
60945
clause 10.5Passed Passed Failed
Immunity to surge on a.c.
power lines
60945
clause 10.6Passed
Radiated emissions60945
clause 9.3Passed Passed Passed
Conducted emissions60945
clause 9.2Passed Passed Passed
DANAK-1911419 Rev. ADELTA-A507381Page 12 of 46
RAS/lko
4.2 Immunity to power supply failure
Specification & Test method
IEC 60945, clause 10.8.
Procedure
The power supply is interrupted 3 times within 5 minutes with a break time of 60
seconds.
Normal power-up procedure is to be obtained after each power break.
Results
No malfunction was observed during the exposure, and the function of the test objects
was OK after each exposure.
One of the power supply failures was made during the boot sequence.
Performance criterion: C.
4.3 Extreme variation in power supplies
Specification & Test method
IEC 60945, clause 5.2.2.
Procedure (230 VAC supplied)
Unom. = Nominal supply voltage = 230 VAC
fnom. = Nominal supply frequency = 50 Hz
Exposures, each with a duration of 15 minutes, are performed at the following supply
voltages and frequencies:
U = Unom. + 10 % = 253 VAC
U = Unom. - 10 % = 207 VAC
f = fnom. + 5 % = 52.5 Hz
f = fnom. - 5 % = 47.5 Hz
Results
No malfunction was observed during the exposure, and the function of the test object
was OK after the exposure.
Performance criterion: A.
DANAK-1911419 Rev. ADELTA-A507381Page 13 of 46
RAS/lko
4.4 Immunity to power supply short-term variation
Specification & Test method
IEC 60945:2002, clause 10.7.
Procedure
Unom. = Nominal supply voltage = 230 VAC
fnom. = Nominal supply frequency = 50 Hz
Ten exposures, 1 / min, are carried out at each of the following combinations:
Unom. + 20 % = 276 VAC Duration = 1.5 s
fnom. + 10 % = 55 Hz Duration = 5.0 s
Unom. - 20 % = 184 VAC Duration = 1.5 s
fnom. - 10 % = 45 Hz Duration = 5.0 s
The test object is observed during the exposures, and a functional test is performed at the
end of each combination.
Results
No malfunction was observed during the exposure, and the function of the test object
was OK after the exposure.
Performance criterion: A.
4.5 Extreme variation in power supplies
Specification & Test method
IEC 60945, clause 5.2.2.
Procedure (24 VDC input)
Unom. = Nominal supply voltage = 24 VDC
Exposures, each with a duration of 15 minutes, are performed at the following supply
voltages:
U1 = Un +30 % = 31.2 VDC
U2 = Un -25 % = 18.0 VDC
The test object is observed during the exposures, and a functional test is performed at the
end of each exposure.
An additional power supply variations test is performed as part of the functional test
during the low temperature and the dry heat exposures.
DANAK-1911419 Rev. ADELTA-A507381Page 14 of 46
RAS/lko
Results
No malfunction was observed during the exposure, and the function of the test objects
was OK after the exposure.
Performance criterion: A.
4.6 Excessive conditions - Reverse polarity
Specification & Test method
IEC 60945:2002, clause 5.2.3.
Procedure (DC supplied)
The test object is subjected to an input from a power supply of reversed polarity for a
period of 5 minutes.
After completion of the test, and reset of the protection of the test object, if required, the
power supply shall be connected normally and a performance check shall be carried out.
Results
No malfunction was observed during the exposure and the function of the test object was
OK after the exposure.
4.7 Excessive conditions - Excessive voltage
Specification & Test method
IEC 60945:2002, clause 5.2.3.
Severity and procedure
AC Power Supply Excessive Conditions Test.
Unom. = Nominal supply voltage = 230 VAC
Excessive low voltage : V nom. – 20% = 92 VAC
Excessive high voltage : Vnom. + 20% = 276 VAC
The test object is exposed to each of the excessive voltages for a period of 15 minutes.
The excessive current test is automatically performed together with the excessive low
voltage operation. When the test object is operated at Excessive low voltage, the test
object is also operated with the highest input current.
A functional test is performed to verify correct operation during the test exposure.
DANAK-1911419 Rev. ADELTA-A507381Page 15 of 46
RAS/lko
Performance criterion: A.
Results
No malfunction was observed during the exposure and the function of the test object was
OK after the exposure.
4.8 Immunity to electrostatic discharge
Specifications
IEC 60945, clause 10.9.
Test method
IEC 61000-4-2:2001: Testing and measurement techniques - Electrostatic discharge
immunity test.
Severity and procedure
Air discharge : 2, 4 and 8 kV
Contact discharge : 2, 4 and 6 kV
Energy storage capacitance : 150 pF
Discharge resistance : 330
Polarity : + and -
Number of discharges : 10 per polarity at each test point
The discharges are applied only to such points and surfaces of the test object, which are
accessible to personnel during normal use.
Contact discharges are applied to conductive surfaces and coupling planes. Air
discharges are applied to insulating surfaces.
The test object is energised and in normal operational mode during the exposure. The
test object is observed during the exposure, and a functional test is performed after the
exposure.
Results
No malfunction was observed during the exposure and the function of the test object was
OK after the exposure.
Performance criterion: B.
DANAK-1911419 Rev. ADELTA-A507381Page 16 of 46
RAS/lko
4.9 Immunity to radiated radiofrequencies
Specifications
IEC 60945, clause 10.4.
Test method
IEC 61000-4-3:2006: Testing and measurement techniques - Radiated, radio-frequency,
electromagnetic field immunity test.
Severity and procedure
IEC 60945
Frequency range : 80 - 2000 MHz
Field strength : 10 V/m
Modulation : 80 %AM, 400 Hz sine wave
Sweep rate : 0.0015 decade / second (80 MHz – 1 GHz)
Sweep rate : 0.0005 decade / second (1 GHz – 2 GHz)
The test is performed in an anechoic room. The field is generated using linearly
polarised broadband antennas.
The test object is energised and in normal operational mode during the exposure. The
test object is observed during the exposure and a functional test is performed after the
exposure.
Results
No malfunction was observed during the exposure and the function of the test objects
were OK after the exposure.
Performance criterion: A.
4.10 Immunity to conducted radio frequency disturbance
Specification
IEC 60945, clause 10.3.
Test method
IEC 61000-4-6:2007: Testing and measurement techniques - Immunity to conducted
disturbances, induced by radio-frequency fields.
DANAK-1911419 Rev. ADELTA-A507381Page 17 of 46
RAS/lko
Severity and procedure
Frequency range : 150 kHz - 80 MHz
Amplitude : 10 V r.m.s. amplitude swept over the frequency range 150 kHz
to 80 MHz (severity level 2); including 10 V r.m.s amplitude at
spot frequencies: 2 MHz, 3 MHz, 4 MHz, 6.2 MHz, 8.2 MHz,
12.6 MHz, 16.5 MHz, 18.8 MHz, 22 MHz and 25 MHz.
Dwell time : 3 seconds during sweeping and at spot frequencies.
Sweep rate : ≤ 1.5 x 10-3 decades/s
Modulation : 80 %AM, 400 Hz sine wave
The test object is supplied with power via a coupling / decoupling network.
The test signal is coupled to the power lines and signal lines via coupling networks or via
an EM clamp. The coupling impedance is 150 .
The test object is energised and in normal operational mode during the exposure. The
test object is observed during the exposure, and a functional test is performed after the
exposure.
Results
No malfunction was observed during the exposure, and the function of the test objects
were OK after the exposure.
Performance criterion: A.
4.11 Immunity to fast transients on a.c. power, signal and control lines
Specifications
IEC 60945, clause 10.5.
Test method
IEC 61000-4-4:2004: Testing and measurement techniques - Section 4: Electrical fast
transient / burst immunity test.
Severity and procedure
Amplitude : 2 kV on power lines
: 1 kV on signal lines
Pulse rise time : 5 ns
Pulse duration : 50 ns
Generator impedance : 50
DANAK-1911419 Rev. ADELTA-A507381Page 18 of 46
RAS/lko
Repetition rate : 5 kHz
Burst duration : 15 ms
Burst period time : 300 ms
Power port
The test object is supplied with power via a transient coupling network. The test signal is
successively coupled to each power line and protective earth with reference to the
ground plane.
The test signal is injected on the power lines for 5 minutes, using each coupling mode
and each polarity, and then on the signal lines for 5 minutes using each polarity.
Signal lines
The test signal is injected on the signal lines using a capacitive coupling clamp. The
clamp is successively used on selected signal cables.
The test object is energised and in normal operational mode during the exposure. The
test object is observed during the exposure and a functional test is performed after the
exposure.
Results
Test objects 2.1.1 and 2.1.2:
No malfunction was observed during the exposure and the function of the test objects
was OK after the exposure.
Test object 2.1.3:
Malfunction was observed during the exposure and the function of the test object was
not OK after the exposure.
Performance criterion: B.
4.12 Immunity to surges on a.c. power lines
Specifications
IEC 60945, clause 10.6.
Test method
IEC 61000-4-5:2005: Testing and measurement techniques - Surge immunity test.
DANAK-1911419 Rev. ADELTA-A507381Page 19 of 46
RAS/lko
Severity and procedure
Amplitude power ports : 1 kV line-to-earth, 0.5 kV line-to-line
Voltage rise time : 1.2 µs (open circuit)
Voltage decay time : 50 µs (open circuit)
The impedance of the test generator is 2 for line-to-line coupling and 12 for line-to-
earth coupling.
The test object is energised and in normal operational mode during the exposure. The
test object is observed during the exposure, and a functional test is performed after the
exposure.
Results
No malfunction was observed during the exposure and the function of the test object was
OK after the exposure.
Performance criterion: B.
4.13 Radiated emissions
Specification
IEC 60945:2002, Section 9.3.
Test methods
CISPR 16-2-3:2006: Specification for radio disturbance and immunity measuring
apparatus and methods - Part 2-3: Methods of measurement of disturbance and immunity
- Radiated disturbance measurements.
Severity and procedure
IEC 60945
Bridge and deck zone.
Frequency range : 0.15 - 2000 MHz
Limits (quasi-peak) : 0.15 - 0.30 MHz : 80 - 52 dBV/m
0.30 - 30 MHz : 52 - 34 dBV/m
30 - 2000 MHz : 54 dBV/m, except for
156 - 165 MHz : 24 dBV/m
The electromagnetic field is measured with antennas at a distance of 3 m.
DANAK-1911419 Rev. ADELTA-A507381Page 20 of 46
RAS/lko
The measuring bandwidth is, 9 kHz in the frequency range 150 kHz - 30 MHz and 120
kHz in the frequency range 30 MHz - 2000 MHz, except for the frequency range 156
MHz - 165 MHz where the measuring bandwidth is 9 kHz.
The test object is energised and in normal operational mode during the measurement.
Results
The radiated emissions were within the specified limits. Test record sheets of the
radiated emission measurements are enclosed in Annex 3.
4.14 Conducted emissions
Specification
IEC 60945:2002, clause 9.2.
Test methods
CISPR16-2-1:2008: Specification for radio disturbance and immunity measuring
apparatus and methods - Part 2-1: Methods of measurement of disturbances and
immunity - Conducted disturbance measurements
Severity and procedure
IACS E10:2006 - Bridge and Deck zone.
Frequency range : 0.01 - 30 MHz
Limits (quasi-peak) : 0.01 - 0.15 MHz : 96 - 50 dBV
0.15 - 0.350 MHz : 60 - 50 dBV
0.35 - 30 MHz : 50 dBV
The radio frequency voltage is measured at the power supply terminals of the test object
by a receiver through an artificial mains network.
The measuring bandwidth is 200 Hz in the frequency range 10 kHz - 150 kHz and 9 kHz
in the frequency range 150 kHz - 30 MHz.
The test object is energised and in normal operational mode during the measurement.
Results
The conducted emissions were within the specified limits. Test record sheets of the
conducted emission measurements are enclosed in Annex 4.
DANAK-1911419 Rev. ADELTA-A507381Page 21 of 46
RAS/lko
Annex 1
List of instruments
DANAK-1911419 Rev. ADELTA-A507381Page 22 of 46
RAS/lko
List of instruments
No. Description Manufacturer Type No.29301 ARTIFICIAL MAINS NETWORK ROHDE & SCHWARZ ESH2-Z529342 REFLECTOMETER COUPLER, 600-
4200 MHzROHDE & SCHWARZ ZPD
29516 IMPULSE VOLTAGE LIMITER ROHDE & SCHWARZ ESH3/Z229691 0.01 - 20 GHz. SYNTH. SWEEPER HEWLETT-PACKARD 83620A29694 1-12 GHz. HORN ANTENNA. LOGIMETRICS AN 8200 F29774 HIGH POWER DIRECTIONAL
COUPLER, 10 kHz-220 MHzWERLATONE 1460
29776 RF POWER SENSOR, 100 kHz-4.2 GHz,ROOM 1
HEWLETT-PACKARD 8482A
29777 RF POWER METER, ROOM 1 HEWLETT-PACKARD 437B, OPT. 00229797 BILOG ANTENNA, 30-2000 MHz CHASE ELECTRICS
LTDCBL 6111A
29815 3-LINE CDN NETWORK, IEC 61000-4-6 MEB M329846 RF GENERATOR, 9 kHz-2.4 GHz MARCONI 202429861 EMI-SOFTWARE Ver. 1.60 ROHDE & SCHWARZ ES-K1, PART:
1026.6790.0229905 ISOTROPIC E-FIELD SENSOR
SYSTEM, 100 MHz-18 GHzEMCO 7121
29911 DIGITAL MULTIMETER W. HPIB HEWLETT-PACKARD 34401A29913 ELECTRICAL FAST TRANSIENT
(BURST) GENERATOREM TEST EFT 500
29914 ELECTRONIC SURGE GENERATOR EM TEST VCS 50029916 AUTOMATIC TEST RECEIVER, 9 kHz-
2.75 GHzROHDE & SCHWARZ ESCS 30
1102.4500.3029984 RF POWER AMPLIFIER, 0.8-2.2 GHz,
200WMILMEGA AS0822-200
29985 BILOG ANTENNA 26-2000 MHz SCHAFFNER/CHASE 6140A29994 ESD GENERATOR, AIR AND CONTACT
DISCHARGEEM TEST ESD 30, P18 & P30
49173 HF GENERATOR Marconi 202449519 SHIELD-LINE CDN NETWORK, IEC
61000-4-6DELTA EMC DEPT. SHIELD-LINE CDN
49534 SPITZENBERGER SPITZENBERGER PHD 13500/B49617 HIGH POWER RF AMPLIFIER, 80-1000
MHz, 500 WTESEQ CBA1G-500
DANAK-1911419 Rev. ADELTA-A507381Page 23 of 46
RAS/lko
Annex 2
Photos
DANAK-1911419 Rev. ADELTA-A507381Page 24 of 46
RAS/lko
Photo 1. Power supply variations.
Photo 2. Electrostatic discharge.
DANAK-1911419 Rev. ADELTA-A507381Page 25 of 46
RAS/lko
Photo 3. Radiated radio frequency interference (80 - 1000 MHz).
Photo 4. Radiated radio frequency interference (1000 - 2000 MHz).
DANAK-1911419 Rev. ADELTA-A507381Page 26 of 46
RAS/lko
Photo 5. Conducted radio frequency interference.
Photo 6. Fast transients (burst).
DANAK-1911419 Rev. ADELTA-A507381Page 27 of 46
RAS/lko
Photo 7. Radiated emission (0.15 - 30 MHz).
Photo 8. Radiated emission (30 - 2000 MHz).
DANAK-1911419 Rev. ADELTA-A507381Page 28 of 46
RAS/lko
Photo 9. Conducted emission.
Photo 10. Conducted emission.
DANAK-1911419 Rev. ADELTA-A507381Page 29 of 46
RAS/lko
Photo 11. Conducted emission.
DANAK-1911419 Rev. ADELTA-A507381Page 30 of 46
RAS/lko
Annex 3
Test record sheets - Radiated emissions
DANAK-1911419 Rev. ADELTA-A507381Page 31 of 46
RAS/lko
DELTA
EUT: 3 stkManufacturer: TranbergOperating Condition: 90 graderTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 09Start of Test: 16-05-2011
0
10
20
30
40
50
60
70
80
Level [dBµV/m]
150k 300k 500k 1M 2M 3M 5M 7M 10M 30M
Frequency [Hz]
MES ME IEC 945 (90 MaxPkLIM ME, IEC 60945, QP Magnetic Emission
DANAK-1911419 Rev. ADELTA-A507381Page 32 of 46
RAS/lko
DELTA
EUT: 3 stkManufacturer: TranbergOperating Condition: 0 graderTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 10Start of Test: 16-05-2011
0
10
20
30
40
50
60
70
80
Level [dBµV/m]
150k 300k 500k 1M 2M 3M 5M 7M 10M 30M
Frequency [Hz]
xx
MES ME IEC 945 (0 MaxPkx MES jn_fin QP
LIM ME, IEC 60945, QP Magnetic Emission
DANAK-1911419 Rev. ADELTA-A507381Page 33 of 46
RAS/lko
DELTA
EUT: 3stkManufacturer: TranbergOperating Condition: Ant 1 m verticalTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 01Start of Test: 16-05-2011
-5
0
10
20
30
40
50
60
Level [dBµV/m]
30M 50M 70M 100M 200M 300M 500M 700M 1G
Frequency [Hz]
x
x
xx
xx
x
x MES Maximering_fin QPMES IEC945 1m 30 MaxPk 1LIM RE, IEC 945, QP Radiated Emission
MEASUREMENT RESULT: "Maximering_fin QP"
16-05-2011 11:26Frequency Level Transd Limit Margin Height Azimuth Polarisation
MHz dBµV/m dB dBµV/m dB cm deg
123.610000 20.20 13.2 54.0 33.8 101.0 213.00 VERTICAL156.775000 -0.70 12.0 24.0 24.7 101.0 100.00 HORIZONTAL159.995000 17.00 11.7 24.0 7.0 101.0 155.00 VERTICAL161.700000 15.90 11.5 24.0 8.1 104.0 178.00 VERTICAL172.490000 9.90 10.7 54.0 44.1 101.0 307.00 HORIZONTAL230.640000 13.00 14.0 54.0 41.0 101.0 126.00 HORIZONTAL667.200000 23.90 24.2 54.0 30.1 186.0 184.00 VERTICAL
DANAK-1911419 Rev. ADELTA-A507381Page 34 of 46
RAS/lko
DELTA
EUT: 3stkManufacturer: TranbergOperating Condition: Ant 4 m horizontalTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 02Start of Test: 16-05-2011
-5
0
10
20
30
40
50
60
Level [dBµV/m]
30M 50M 70M 100M 200M 300M 500M 700M 1G
Frequency [Hz]
x
x
xx
xx
x
x MES Maximering_fin QPMES IEC945 4m 30 MaxPk 1LIM RE, IEC 945, QP Radiated Emission
MEASUREMENT RESULT: "Maximering_fin QP"
16-05-2011 11:26Frequency Level Transd Limit Margin Height Azimuth Polarisation
MHz dBµV/m dB dBµV/m dB cm deg
123.610000 20.20 13.2 54.0 33.8 101.0 213.00 VERTICAL156.775000 -0.70 12.0 24.0 24.7 101.0 100.00 HORIZONTAL159.995000 17.00 11.7 24.0 7.0 101.0 155.00 VERTICAL161.700000 15.90 11.5 24.0 8.1 104.0 178.00 VERTICAL172.490000 9.90 10.7 54.0 44.1 101.0 307.00 HORIZONTAL230.640000 13.00 14.0 54.0 41.0 101.0 126.00 HORIZONTAL667.200000 23.90 24.2 54.0 30.1 186.0 184.00 VERTICAL
DANAK-1911419 Rev. ADELTA-A507381Page 35 of 46
RAS/lko
Annex 4
Test record sheets - Conducted emissions
DANAK-1911419 Rev. ADELTA-A507381Page 36 of 46
RAS/lko
DELTA
EUT: Searchlight halogenManufacturer: TranbergOperating Condition: neutral 230 VACTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 03Start of Test: 16-05-2011
0
20
40
60
80
100
Level [dBµV]
10k 30k 100k 300k 1M 2M 4M 10M 30M
Frequency [Hz]
xxxxxxxxxxxxx
xx
x
xx xxxxxxxx
xx
xxxxxxx
xxx
x
xxxxxx
x
xxxx
xxxxx
x
x
x
xxx
xxx
xxxxxxxx
x
xx
x
x
x
xx
x
x
xxxxxxxxxx
x
x
xxxxxx
xxxxxxxxxx
xx
xxxxx
xx
xxxxxxxxxxxxxxxxx
x
x
x
xxxxxxxx
xx
xxxxxx
x
x
xx
xxxxxxxxxxxxxxxxxxxxxxxxxx
xx
xxxxxxxx
xx
xx
xx
x
xxxxxxxxxxxxxxxx
x
xxxxxxxxxxxxx
x
x
xxxxxxxxxxxxxxxxxxxxxxx
xx
xxxxxxxxxx
x
xxxx
xxxx
x
x
x
xxxx
x
xxxxxxxxxxxxxx
x
x
x
xx
xxx
xxxxxxxxxx
x
x
x
xxxxxxxx
xx
x
xxxxxxxxxxxxxxxx
x
xx
x
xxxxx
xxx
x
x
x
x
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
x
x
x
x
xxxxxxx
xxxxxxxxxxxxxxxxxx
xx
xxxxxxx
xx
x
x
xxxxxxxxx
MES CE 0.01-30 PK- MaxPkx MES CE 0.01-30 QP QPk
LIM CE, E-10 deck bridge Conducted EmissionLIM CE, IEC 60945, QP Conducted Emission
DANAK-1911419 Rev. ADELTA-A507381Page 37 of 46
RAS/lko
DELTA
EUT: Searchlight halogenManufacturer: TranbergOperating Condition: Line 230 VACTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 04Start of Test: 16-05-2011
0
20
40
60
80
100
Level [dBµV]
10k 30k 100k 300k 1M 2M 4M 10M 30M
Frequency [Hz]
MES CE 0.01-30 PK MaxPkLIM CE, IEC 60945, QP Conducted EmissionLIM CE, E-10 deck bridge Conducted Emission
DANAK-1911419 Rev. ADELTA-A507381Page 38 of 46
RAS/lko
DELTA
EUT: 4500802Manufacturer: TranbergOperating Condition: -24 VDCTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 05Start of Test: 16-05-2011
-10
0
20
40
60
80
100
Level [dBµV]
10k 30k 100k 300k 1M 2M 4M 10M 30M
Frequency [Hz]
MES CE 0.01-30 PK MaxPkLIM CE, IEC 60945, QP Conducted EmissionLIM CE, E-10 deck bridge Conducted Emission
DANAK-1911419 Rev. ADELTA-A507381Page 39 of 46
RAS/lko
DELTA
EUT: 4500802Manufacturer: TranbergOperating Condition: 24 VDCTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 06Start of Test: 16-05-2011
-10
0
20
40
60
80
100
Level [dBµV]
10k 30k 100k 300k 1M 2M 4M 10M 30M
Frequency [Hz]
MES CE 0.01-30 PK MaxPkLIM CE, IEC 60945, QP Conducted EmissionLIM CE, E-10 deck bridge Conducted Emission
DANAK-1911419 Rev. ADELTA-A507381Page 40 of 46
RAS/lko
DELTA
EUT: 4500801Manufacturer: TranbergOperating Condition: 24 VDCTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 07Start of Test: 16-05-2011
-10
0
20
40
60
80
100
Level [dBµV]
10k 30k 100k 300k 1M 2M 4M 10M 30M
Frequency [Hz]
MES CE 0.01-30 PK MaxPkLIM CE, IEC 60945, QP Conducted EmissionLIM CE, E-10 deck bridge Conducted Emission
DANAK-1911419 Rev. ADELTA-A507381Page 41 of 46
RAS/lko
DELTA
EUT: 4500801Manufacturer: TranbergOperating Condition: -24 VDCTest Site: EMC - 5Operator: PFN - A507381Test Specification: IEC 60945Comment: Sheet 08Start of Test: 16-05-2011
-10
0
20
40
60
80
100
Level [dBµV]
10k 30k 100k 300k 1M 2M 4M 10M 30M
Frequency [Hz]
MES CE 0.01-30 PK MaxPkLIM CE, IEC 60945, QP Conducted EmissionLIM CE, E-10 deck bridge Conducted Emission
DANAK-1911419 Rev. ADELTA-A507381Page 42 of 46
RAS/lko
Annex 5
Test setup and functional test procedure (from Client)
(This annex is informative and not part of the accredited report)
DANAK-1911419 Rev. ADELTA-A507381Page 43 of 46
RAS/lko
DANAK-1911419 Rev. ADELTA-A507381Page 44 of 46
RAS/lko
DANAK-1911419 Rev. ADELTA-A507381Page 45 of 46
RAS/lko
DANAK-1911419 Rev. ADELTA-A507381Page 46 of 46
RAS/lko