TI437P/00/EN/12.09 No. 71107333 Technical Information Deltapilot M FMB50/51/52/53 Hydrostatic level measurement Pressure sensor with the CONTITE TM measuring cell Condensate-resistant offering long-term stability; HART communication. Application The hydrostatic pressure sensor is used for the following measuring tasks: Hydrostatic pressure measurement in liquids and paste-like media in all areas of process engineering, process measuring technology, pharmaceuticals and the food industry Level, volume or mass measurements in liquids Your benefits Very good reproducibility and long-term stability Turn down 100:1 Hermetically sealed CONTITE TM measuring cell: Condensate-resistant and climatic-proofed High reference accuracy: ±0.2 %, optionally ±0.1 % Minimum temperature effects End-to-end modularity for differential pressure, hydrostatics and pressure (Deltabar M – Deltapilot M – Cerabar M), e.g. replaceable display universal electronics Easy commissioning without the need for an operating tool Menu-guided operation onsite via 4 to 20 mA with HART Wide range of approvals (e.g. ATEX, FM, CSA, etc.) for international use

Upload: trinhdiep

Post on 10-Jan-2017

220 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Deltapilot M FMB50/51/52/53 (Technische Information)

TI437P/00/EN/12.09

No. 71107333

Technical Information

Deltapilot M FMB50/51/52/53Hydrostatic level measurement

Pressure sensor with the CONTITETM measuring cell

Condensate-resistant offering long-term stability; HART

communication.

Application

The hydrostatic pressure sensor is used for the following

measuring tasks:

• Hydrostatic pressure measurement in liquids and

paste-like media in all areas of process engineering,

process measuring technology, pharmaceuticals and

the food industry

• Level, volume or mass measurements in liquids

Your benefits

• Very good reproducibility and long-term stability

• Turn down 100:1

• Hermetically sealed CONTITETM measuring cell:

– Condensate-resistant and climatic-proofed

– High reference accuracy: ±0.2 %,

optionally ±0.1 %

– Minimum temperature effects

• End-to-end modularity for differential pressure,

hydrostatics and pressure (Deltabar M –

Deltapilot M – Cerabar M), e.g.

– replaceable display

– universal electronics

• Easy commissioning without the need for an operating

tool

• Menu-guided operation onsite via 4 to 20 mA with

HART

• Wide range of approvals (e.g. ATEX, FM, CSA, etc.) for

international use

Page 2: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

2 Endress+Hauser

Table of contents

Function and system design. . . . . . . . . . . . . . . . . . . . . 4

Device selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Level measurement in closed tanks with pressure overlay . . . . . . . 7

Density measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Level measurement with automatic density correction (with media

changing in the tank) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Electrical differential pressure measurement with gauge pressure

sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Communication protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

System integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Explanation of terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Signal range – 4 to 20 mA HART . . . . . . . . . . . . . . . . . . . . . . . . 11

Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Dynamic behavior: current output . . . . . . . . . . . . . . . . . . . . . . . 12

Dynamic behavior: HART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Damping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Cable entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Residual ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Influence of power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Performance characteristics. . . . . . . . . . . . . . . . . . . . 16

Reference operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Long-term stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Influence of orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Calibration position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Reference accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Total performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Total error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Thermal change in the zero output and the output span . . . . . . . 17

Operating conditions (installation) . . . . . . . . . . . . . . 18

General installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . 18

FMB50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

FMB51/FMB52/FMB53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Supplementary installation instructions . . . . . . . . . . . . . . . . . . . . 19

Wall and pipe mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

"Separate housing" version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Oxygen applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Silicone-free applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Applications with hydrogen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Special measuring cells for acids, alkalis or sea water

(not FMB50) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Operating conditions (environment) . . . . . . . . . . . . . 22

Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Overvoltage protection (optional) . . . . . . . . . . . . . . . . . . . . . . . . 23

Operating conditions (process) . . . . . . . . . . . . . . . . . 24

Process temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Lateral load FMB51 (static) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Pressure specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 25

F31 aluminum housing dimensions . . . . . . . . . . . . . . . . . . . . . . 25

F15 stainless steel housing dimensions (hygienic) . . . . . . . . . . . . 25

Process connections FMB50 (compact version) . . . . . . . . . . . . . . 25

Process connections FMB51 (rod version) . . . . . . . . . . . . . . . . . 31

Process connections FMB52 (cable version) . . . . . . . . . . . . . . . . 32

Dimensions of Deltapilot M FMB53 (suspension clamp and

mounting bracket) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Wall and pipe mounting with "Separate housing" version . . . . . . 34

Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Human interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Local operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Certificates and approvals . . . . . . . . . . . . . . . . . . . . . 42

CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Ex approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Suitability for hygienic processes . . . . . . . . . . . . . . . . . . . . . . . . . 42

Standards and guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Pressure Equipment Directive (PED) . . . . . . . . . . . . . . . . . . . . . 42

Drinking water approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

Ordering information. . . . . . . . . . . . . . . . . . . . . . . . . 43

FMB50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

FMB50 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

FMB50 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

FMB50 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

FMB51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

FMB51 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

FMB51 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

FMB52 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

FMB52 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

FMB52 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

FMB53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

FMB53 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

FMB53 (continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Technical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Brief Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Page 3: Deltapilot M FMB50/51/52/53 (Technische Information)

3 Endress+Hauser

Deltapilot M FMB50/51/52/53

Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Installation/Control Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Suspension clamp (FMB53 only) . . . . . . . . . . . . . . . . . . . . . . . . 58

Extension cable shortening kit (FMB53 only) . . . . . . . . . . . . . . . 58

M12 connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

Welding necks and Weld-in tool flanges . . . . . . . . . . . . . . . . . . . 58

UNI process adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Configuration data sheet (HART) . . . . . . . . . . . . . . . 60

Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Page 4: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

4 Endress+Hauser

Function and system design

Device selection

Deltapilot M –

Product family

FMB50

P01-FMB5xxxx-14-xx-xx-xx-000

Compact version

FMB51

P01-FMB5xxxx-14-xx-xx-xx-001

Rod version

FMB52

P01-FMB5xxxx-14-xx-xx-xx-002

Cable version

FMB53

P01-FMB5xxxx-14-xx-xx-xx-003

Cable version with

mounting clamp

Field of application – Level measurement

– Pressure measurement

Industries Food, pharmaceuticals, chemicals Environment (freshwater and

wastewater)

Process connections – Thread

– Flanges

– Flush-mounted hygienic

connections

– Thread

– Flanges

– Thread

– Flanges

Suspension clamp

Measuring ranges From –0.1 to +0.1 (-1,45 to +1,45 psi) bar to –1 bar to +10 bar (-14,5 to 145 psi)

OPL 1) Max. 40 bar (600 psi)

Process temperature range –10 to +100°C (+14 to +212°F)

(+135°C (275°F) for 30 minutes

maximum)

–10 to +85°C

(+14 to +185°F)

With PE cable: –10 to +70°C (+14 to +158°F)

With FEP cable: –10 to +80°C (+14 to +176°F)

Ambient temperature range • Without LCD display: -40 to +85°C (-40 to +185°F)

• With LCD display: -20 to +70°C (-4 to +158°F) (extended temperature application range -40 to 85°C (-40 to +158°F) with

restrictions in optical properties such as display speed and contrast)

• Separate housing: –20 to +60°C (–4 to +140°F)

Reference accuracy 0.2 % (option 0.1 %) depends on the measuring range ä 16

Supply voltage – 11.5 to 45 V DC (versions with plug-in connection 35 V DC)

– For intrinsically safe device versions: 11.5 to 30 V DC

Output 4 to 20 mA with superimposed HART protocol

Options – Gold/rhodium-coated process isolating diaphragm

– 3.1 inspection certificate

– 3A approval and EHEDG approval for FMB50 (pending)

– Specific firmware versions

– Initial device settings can be ordered

– Separate housing

Specialties – Absolute resistance to condensate thanks to hermetically sealed CONTITETM cell

– Maximum flexibility thanks to modular design

– Special cleaning of the transmitter to remove paint-wetting substances, for use in paint shops

1) OPL = over pressure limit; depends on the lowest-rated element, with regard to pressure, of the selected components

Page 5: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 5

FMB50/51/52 universal application

• Modular probe program to ensure optimum process adaptation

• FMB50 compact version: installation in the tank from below or from the side

• FMB51/52 rod and cable extension: installation from above, i.e. easy to retrofit ground tanks, no additional

opening in the tank floor

FMB50 optimized for the food-processing and pharmaceutical industry

• All typical flush-mounted process connections can be supplied

• Welding flanges

• Stainless steel housing

• All the sanitary process connections are gap-free and can be cleaned so that the unit is free of residue, e.g.

CIP cleaning

• USDA/H1-approved transfer liquid as per FDA Directive

• 3A approval or EHEDG approvals (pending)

P01-DB5xxxxx-12-xx-xx-xx-004

FMB53 for level measurement in water and wastewater

• The housing with the electronic insert is mounted outside shafts and tanks in such a way that it is protected

from flooding. The extension cable is secured with a suspension clamp.

• The measuring cell tube made of stainless steel (AISI 316L) and the Alloy process isolating diaphragm allow

use in aggressive media such as wastewater for example.

• Extension cable up to 400 m (1312 ft) in length (up to 100 m (328 ft) in Ex-areas) without strain relief.

• Special measuring cell with gold/rhodium coating for applications in which severe hydrogen formation can

occur (e.g. digested sludge); ä 21.

• Special measuring cell with gold/platinum coating for acids, alkalis or sea water; ä 21.

74 -74 -

Page 6: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

6 Endress+Hauser

Measuring principle

P01-FMB5xxxx-15-xx-xx-xx-004

Deltapilot M hydrostatic level measurement and measuring principle

1 Rear isolating membrane of the CONTITE™ measuring cell

2 Measuring element

3 Process isolating diaphragm

g Gravitational acceleration

h Level height

p ges Total pressure = hydrostatic pressure + atmospheric pressure

p atm Atmospheric pressure

p hydr. Hydrostatic pressure

p mess Measured pressure in the measuring cell = hydrostatic pressure

Density of the medium

Due to its weight, a liquid column creates hydrostatic pressure. If the density is constant, the hydrostatic

pressure depends solely on the height h of the liquid column.

The CONTITE™ measuring cell, which works on the principle of the gauge pressure sensor, constitutes the

core of Deltapilot M. In contrast to conventional gauge pressure sensors, the precision measuring element (2)

in the CONTITE™ measuring cell is absolutely protected, situated between the process isolating diaphragm

(3) and the rear isolating membrane (1). Thanks to this hermetic sealing of the measuring element, the

CONTITE™ measuring cell is absolutely insensitive to condensate/condensation and aggressive gases. The

pressure applied is transferred from the process isolating diaphragm to the measuring element by means of an

oil without any loss in pressure.

Two temperature sensors, which measure the distribution of temperature in the cell, are arranged between the

process isolating diaphragm and measuring element. The electronics can compensate any measuring errors

resulting from fluctuations in temperature with these measured temperature values.

A linearization function with max. 32 points, based on a table entered either manually or semi-automatically,

can be activated locally or remotely. This function facilitates

measurement in engineering units, and provides a linear output signal for spherical and horizontal cylindrical

tanks, and vessels with a conical outlet.

hh =

p� · g

h p

pa

tm

hydr.p

patm

patm

gesp

hydr.p+p

atm=gesp

)hydr.

p+(patm

patm

pmess = –

pges

patm

pmess = –p

gesp

atmp

mess = –

123

Page 7: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 7

Level measurement in closed

tanks with pressure overlay

You can determine the differential pressure in tanks with pressure overlay using two Deltapilot M. The pressure

measured values of the two probes are sent to a signal processing unit such as Endress+Hauser RMA or a PLC.

The signal processing unit or PLC determines the difference in pressure and uses this to calculate the level and

the density where necessary.

P01-FMB5xxxx-15-xx-xx-xx-005

Level measurement in a closed tank with pressure overlay

1 Probe 1 measures the total pressure (hydrostatic pressure and top pressure)

2 Probe 2 measures the top pressure

3 Signal processing unit determines the difference in pressure and uses this to calculate the level

Note!

• When selecting the Deltapilot M probes, make sure you select measuring ranges that are sufficiently wide

( see example).

• The process isolating diaphragm of probe 2 must not be flooded. This generates additional hydrostatic

pressure which distorts the measurement.

• The ratio of hydrostatic pressure to top pressure should be no more than 1:6.

Example:

• Max. hydrostatic pressure = 0.6 bar (9 psi)

• Max. top pressure (probe 2) = 0.3 bar (4.5 psi)

• Max. total pressure, measured with probe 1 = 0.3 bar (4..5 psi) + 0.6 bar (9 psi) = 0.9 bar (13.5 psi)

Measuring cell to be selected: 0 to 1.2 bar (0 to 18 psi)

• Max. pressure, measured with probe 2: 0.3 bar (4.5 psi)

Measuring cell to be selected: 0 to 0.4 bar (0 to 6 psi)

Density measurement You can measure the density in tanks with pressure overlay using two Deltapilot M and a signal processing unit

or a PLC. The signal processing unit or the PLC calculates the density from the known distance h between

the two probes and the two measured values p1 and p2.

P01-FMB5xxxx-15-xx-xx-xx-006

Level measurement in a closed tank with pressure overlay

1 Deltapilot M determines pressure measured value p1

2 Deltapilot M determines pressure measured value p2

3 Signal processing unit determines the density from the two measured values p1 and p2 and the distance h

p2

p1

�h

Page 8: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

8 Endress+Hauser

Level measurement with

automatic density correction

(with media changing in the

tank)

Level measurement with automatic density correction is possible in conjunction with a limit switch such as

Liquiphant and a PLC. The limit switch always switches at the same level. In the switch point, the signal

processing unit determines the corrected density from the pressure of the Deltapilot M currently measured and

the known distance between Deltapilot M and the limit switch. The signal processing unit then calculates the

level from the new density and the measured pressure of the Deltapilot M.

P01-FMB5xxxx-15-xx-xx-xx-007

Level measurement with automatic density correction

1 Deltapilot M

2 Liquiphant

3 PLC

Electrical differential pressure

measurement with gauge

pressure sensors

P01-FMB5xxxx-14-xx-xx-xx-004

1 Shut-off valves

2 e.g. filter

In the example given, two Deltapilot M devices (each with a gauge pressure sensor) are interconnected. The

pressure difference can thus be measured using two independent Deltapilot M devices.

" Caution!

If using intrinsically safe devices, strict compliance with the rules for interconnecting intrinsically safe circuits

as stipulated in IEC60079-14 (proof of intrinsic safety) is mandatory.

Communication protocol • 4 to 20 mA with HART communication protocol

System integration The device can be fitted with a tag name and a preset bus address, see ä 43 ff "Ordering information"

feature 895 "Identification:" version "Z1" and "Z2".

�h

FieldgateFXA520

FX

N 5

20

FX

N 5

20

Multidrop-ConnectorFXN520

Deltapilot M

Page 9: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 9

Input

Measured variable Hydrostatic pressure

Measuring range

Nominal

value

Range limit Smallest span

(factory calibration)1)

MWP 2) OPL 3) Vacuum resistance 4) Version in the

order code 5)

lower (LRL) 6) upper (URL) Synthetic oil/

Inert oil

[bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [barabs (psiabs)]

0.1 (1.45) –0.1 (-1.5) +0.1 (+1.5) 0.01 (0.15) 2.7 (40.5) 4 (60) 0.01/0.04

(0,15/0,6)

1C

0.4 (6) –0.4 (-6) +0.4 (+6) 0.02 (0.3) 5.3 (79.5) 8 (120) 1F

1.2 (18) –1 (-15) +1.2 (+18) 0.06 (1) 16 (240) 24 (360) 1H

4 (60) –1 (-15) +4 (+60) 0.2 (3) 16 (240) 24 (360) 1M

10 (150) –1 (-15) +10 (+150) 0.5 (7.5) 27 (405) 40 (600) 1P

1) Recommended Turn down: Max 100:1.

Factory calibration Turn down: Max 20:1, higher on request.

2) The MWP (maximum working pressure) for the measuring device depends on the lowest-rated element, with regard to pressure, of the selected components,

i.e. the process connection ( ä 25 ff) has to be taken into consideration in addition to the measuring cell (see Table above). Pay attention to the

pressure-temperature dependence also. For the appropriate standards and other information, see ä 24, Pressure specifications section.

3) OPL: over pressure limit; depends on the lowest-rated element, with regard to pressure, of the selected components

4) The vacuum resistance applies to the measuring cell at reference conditions.

5) ä 43 ff, "Ordering information" section, feature 70 "Sensor range"

6) By default, the device is set to a lower range limit of 0 bar. Please specify in the order if the lower range limit is to be set to a different default value.

Page 10: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

10 Endress+Hauser

Explanation of terms Explanation of terms: turn down (TD),

set span and span based on zero point

Case 1:

• Lower range value (LRV) Upper range value

(URV)

Example:

• Lower range value (LRV) = 0 mbar

• Upper range value (URV) = 40 mbar (0.6 psi)

• Nominal value (URL) = 400 mbar (6 psi)

Turn down:

• TD = URL /URV:1

Set span:

• URV – LRV = 40 mbar (0.6 psi)

This span is based on the zero point. P01-DBxxxxxx-05-xx-xx-xx-001

Example: 400 mbar (6 psi) measuring cell

Case 2:

• Lower range value (LRV) Upper range value

(URV)

Example:

• Lower range value (LRV) = –200 mbar (3 psi)

• Upper range value (URV) = 0 bar

• Nominal value (URL) = 400 mbar (6 psi)

Turn down:

• TD = URL /(LRV) = 2:1

Set span:

• URV – LRV = 200 mbar (3 psi)

This span is based on the zero point.P01-DBxxxxxx-05-xx-xx-xx-002

Example: 400 mbar (6 psi) measuring cell

1 Set span

2 Span based on zero point

3 Nominal value i upper range limit (URL)

4 Nominal measuring range

5 Sensor measuring range

LRL Lower range limit

URL Upper range limit

LRV Lower range value

URV Upper range value

–400 mbar 0 +400 mbar40

LRL LRV URLURV

➁➀ =

–400 mbar +400 mbar

LRV URLURV

0

LRL

–200 mbar

➁➀ =

Page 11: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 11

Output

Output signal • 4 to 20 mA with superimposed digital communication protocol HART 6.0, 2-wire

Signal range –

4 to 20 mA HART

3.8 to 20.5 mA

Signal on alarm As per NAMUR NE 43

• 4 to 20 mA HART

Options:

– Max. alarm: can be set from 21 to 23 mA (Factory setting: 22 mA)

– Hold measured value: last measured value is held

– Min. alarm: 3.6 mA

Load

P01-xxxxxxxx-05-xx-xx-xx-002

Load diagram

1 Power supply 11.5 to 30 V DC for intrinsically safe device versions

2 Power supply 11.5 to 45 V DC (versions with plug-in connector 35 V DC) for other types of protection and for

uncertified device versions

RLmax Maximum load resistance

U Supply voltage

Note!

When operating via a handheld terminal or via a PC with an operating program, a minimum communication

resistance of 250 must be taken into account.

Resolution • Current output: 1 A

• Display: can be set (factory setting: presentation of the maximum accuracy of the transmitter)

U – 11.5 VRLmax 0.023 A

302011.5 U[V]

40 45

1239

1456

804

369

[ ]�RLmax

Page 12: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

12 Endress+Hauser

Dynamic behavior:

current output

Dead time, time constant (T63)

P01-xxxxxxxx-05-xx-xx-xx-007

Presentation of the dead time and the time constant

Dynamic behavior: HART Dead time, time constant (T63)

A typical configuration for the PLC of 2 to 3 values per second results in the following total dead time:

Reading cycle

HART commands: 2 to 3 per second on average.

The Deltapilot M commands the BURST MODE function for cyclic value transmission via the HART

communication protocol.

Response time

250 ms

Cycle time (update time)

On average 310 to 520 ms.

Damping A damping affects all outputs (output signal, display).

• Via local display, handheld terminal or PC with operating program, continuous from 0 to 999 s

• Additionally for HART: via DIP switch on the electronic insert, switch position "on" = value set in the

software (factory setting: 2 s) and "off"

I

63 %

100 %

tt1 t2

90 %

Type Dead time t1 [ms] Time constant (T63), t2 [ms]

FMB50 < 55 < 65

FMB51/52/53 < 500 < 250

Type Dead time t1 [ms] Time constant (T63), t2 [ms]

FMB50 305 < 65

FMB51/52/53 750 < 250

Page 13: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 13

Power supply

Electrical connection Note!

• When using the measuring device in hazardous areas, installation must comply with the corresponding

national standards and regulations and the Safety Instructions or Installation or Control Drawings.

ä 56 ff, "Safety Instructions" and "Installation/Control Drawings" sections.

• Overvoltage protection HAW569Z for the non-hazardous area and for ATEX II 1/2 G Exi can be ordered as

an option (see "Ordering information" section).

• Protective circuits against reverse polarity, HF influences and overvoltage peaks are installed.

4 to 20 mA HART

P01-xMx5xxxx-04-xx-xx-xx-004

Electrical connection 4 to 20 mA HART

1 Housing

2 External ground terminal

3 Internal ground terminal

4 Power supply terminals

5 Test terminals, see "Taking 4 to 20 mA test signal"

6 Minimum supply voltage = 11.5 V DC

Taking 4 to 20 mA test signal

A 4 to 20 mA test signal may be measured via the test terminals without interrupting the measurement.

4…20 mA

11.5 V DC

- +

6

1 2

3

4

5

Page 14: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

14 Endress+Hauser

Devices with valve connector

P01-xMx5xxxx-04-xx-xx-xx-005

Left: electrical connection for devices with a valve connector

Right: view of the connector at the device

Devices with Harting connector Han7D

P01-xxx7xxxx-04-xx-xx-xx-001

Left: electrical connection for devices with a Harting connector Han7D

Right: view of the connection at the device

Devices with M12 connector

P01-xxx7xxxx-04-xx-xx-xx-000

Left: electrical connection for devices with an M12 connector

Right: view of the connector at the device

Endress+Hauser offers the following accessories for devices with an M12 connector:

Plug-in jack M 12x1, straight

• Material: body PA; coupling nut CuZn, nickel-plated

• Degree of protection (fully locked): IP67

• Order number: 52006263 or through device order, see also ä 43 ff "Ordering information" section

Plug-in jack M 12x1, elbowed

• Material: body PBT; coupling nut GD-Zn, nickel-plated

• Degree of protection (in screwed situation): IP67

• Order number: 71091284 or through device order, see also ä 43 ff "Ordering information" section

–+

+ –

+–

Han7D

–+

+ – –

+

15

4

67

8

2

3

M12

–+

+ – – +

Page 15: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 15

Cable 4x0.34 mm2 (20 AWG) with M12 socket, elbowed, screw plug, 5 m (16 ft) length

• Material: body PUR; coupling nut CuSn/Ni; cable PVC

• Degree of protection (fully locked): IP67

• Order number: 52010285 or through device order, see also ä 43 ff "Ordering information" section

Devices with 7/8" connector

P01-xxx7xxxx-04-xx-xx-xx-003

Left: electrical connection for devices with a 7/8" connector

Right: view of the connector at the device

Cable gland

Terminals

For wire cross-sections of 0.5 to 2.5 mm² (20 to 14 AWG)

Supply voltage Note!

• When using the measuring device in hazardous areas, installation must comply with the corresponding

national standards and regulations and the Safety Instructions or Installation or Control Drawings.

• All explosion protection data are given in separate documentation which is available upon request. The

Ex documentation is supplied as standard with all devices approved for use in explosion hazardous areas.

ä 56 ff, "Safety Instructions" and "Installation/Control Drawings" sections.

4 to 20 mA HART

• 11.5 to 45 V DC

(Versions with plug-in connection 35 V DC)

• For intrinsically save device versions: 11,5...30 V DC

Cable entry ä 43 ff, feature 50 "Electrical connection".

Cable specification • Endress+Hauser recommends using twisted, shielded two-wire cables.

• Terminals for wire cross-sections 0.5 to 2.5 mm2 (20 to 14 AWG)

• Cable outer diameter: 5 to 9 mm (0.2 to 0.35 in)

Residual ripple No influence on 4 to 20 mA signal up to 5 % residual ripple within the permitted voltage range [according to

HART hardware specification HCF_SPEC-54 (DIN IEC 60381-1)]

Influence of power supply 0.0006 % of URL/1 V

+7/8”

–+

+ –

Approval Type Clamping area

Standard, CSA GP

ATEX II1/2G or II2G Ex ia,

IEC Ex ia Ga/Gb or Ex ia Gb,

FM/ CSA IS

Plastic M20x1.5 5 to 10 mm (0,2 to 0,39 in)

ATEX II1/2D Ex t, II1/2GD Ex ia,

II3G Ex nA,

IEC Ex t Da/Db

Metal M20x1.5 (Ex e) 7 to 10.5 mm (0,28 to 0,41 in)

Page 16: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

16 Endress+Hauser

Performance characteristics

Reference operating

conditions

• As per IEC 60770

• Ambient temperature TA = constant, in the range of: +21 to +33°C (+70 to 91 °F)

• Humidity = constant, in the range of: 5 to 80 % RH

• Ambient pressure pA = constant, in the range of: 860 to 1060 mbar (12.47 to 15.37 psi)

• Position of the measuring cell: constant, in range:

FMB50: horizontally 1°

FMB51/FMB52/FMB53: vertically 1°

• Input of LOW SENSOR TRIM and HIGH SENSOR TRIM for lower range value and upper range value

• Span based on zero point

• Material of the process isolating diaphragm: Alloy C276 (2.4819) and Alloy C276 with coating (AuRh or

AuPt)

• Measuring cell material (meter body): Alloy C276, 316L/1.4435

• Filling oil: synthetic oil (FDA)/inert oil

• Supply voltage: 24 V DC ± 3 V DC

• Load with HART: 250 • HART warm-up period:

– FMB50 = <5 s

– FMB51/FMB52/FMB53 = <8 s

Long-term stability

Influence of orientation • < 2.3 mbar (0.0345 psi) when using synthetic oil (FDA)

• < 5 mbar (0.075 psi) when using inert oil

Note!

Position-dependent zero point shift can be corrected. ä 18, "General installation instructions" section.

Calibration position

Reference accuracy The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-

reproducibility as per IEC 60770. The data refer to the calibrated span.

Measuring cell Long-term stability [%]

0.1 bar (1,5 psi)• < 0.18 of the upper range limit (URL) / year

• < 0.45 of the upper range limit (URL) / 5 years

0.4 bar (6 psi)

1.2 bar (18 psi)

• < 0.1 of the upper range limit (URL) / year

• < 0.25 of the upper range limit (URL) / 5 years

4 bar (60 psi)

10 bar (150 psi)

• < 0.05 of the upper range limit (URL) / year

• < 0.125 of the upper range limit (URL) / 5 years

➀ FMB50

➁ FMB51, FMB52, FMB53

To minimize the effect of

the orientation (e.g. in the

case of vertical device

installation), position offset

is preset at the factory.

P01-FMB5xxxx-11-xx-xx-xx-001

➀ ➁

Reference accuracy in % of the calibrated span

Measuring cell TD "Standard" option "Platinum" option

0.1 bar (1.5 psi)TD 2:1

TD > 2:1

< 0.2

< 0.1 x TD

< 0.15

< 0.075 x TD

0.4 bar (6 psi)TD 4:1

TD > 4:1

< 0.2

< 0.05 x TD

< 0.15

< 0.0375 x TD

Page 17: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 17

Total performance The "Total performance" specification comprises the non-linearity including hysteresis, non-reproducibility as

well as the thermal change in the zero point.

Total error The total error comprises the long-term stability and the total performance:

Thermal change in the zero

output and the output span

1.2 bar (18 psi)TD 2:1

TD > 2:1

< 0.2

< 0.1 x TD

< 0.1

< 0.05 x TD

4 bar (60 psi)TD 4:1

TD > 4:1

< 0.2

< 0.05 x TD

< 0.1

< 0.025 x TD

10 bar (150 psi)TD 2.5:1

TD > 2.5:1

< 0.2

< 0.08 x TD

< 0.1

< 0.04 x TD

Reference accuracy in % of the calibrated span

Measuring cell TD "Standard" option "Platinum" option

Total performance in % of the URL

Version Measuring cell -10 to +60°C

(+14 to +140 °F)

60 to 85°C

(140 to 185 °F)

85 to 100 C

(185 to 212 °F)

FMB50

FMB51/52/53 snap-on0.1 bar (1.5 psi) < 0.35 < 0.45 < 0.6

FMB51/52/53 welded 0.1 bar (1.5 psi) < 0.8 < 1 < 1.4

FMB50/51/52/53

0.4 bar (6 psi) < 0.35 < 0.45 < 0.6

1.2 bar (18 psi), 4 bar (60 psi),

10 bar (150 psi)< 0.15 < 0.2 < 0.25

Measuring cell % of the URL/year (in the permitted temperature range)

0.1 bar (1.5 psi)• Snap-on: 0.63

• Welded: 1.0

0.4 bar (6 psi) • 0.61

1.2 bar (18 psi) • 0.27

4 bar (60 psi), 10 bar (150 psi) • 0.25

Thermal change in % of the calibrated span

Version Measuring cell -10 to +60°C

(-94 to +752°F)

60 to 85 °C

(+140 to +185°F)

85 to 100 °C

(+140 to +185°F)

FMB50

FMB51/52/53 snap-on0.1 bar (1.5 psi) < (0.32 + 0.30 x TD) < (0.34 + 0.40 x TD) < (0.34 + 0.55 x TD)

FMB51/52/53 welded 0.1 bar (1.5 psi) < (0.32 + 0.50 x TD) < (0.34 + 0.60 x TD) < (0.36 + 0.70 x TD)

FMB50/51/52/53

0.4 bar (6 psi) < (0.31 + 0.25 x TD) < (0.32 + 0.30 x TD) < (0.33 + 0.35 x TD)

1.2 bar (18 psi),

4 bar (60 psi),

10 bar (150 psi)

< (0.31 + 0.10 x TD) < (0.32 + 0.15 x TD) < (0.33 + 0.20 x TD)

Page 18: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

18 Endress+Hauser

Operating conditions (installation)

General installation

instructions

• The position-dependent zero point shift can be corrected:

– directly at the device via an operating key

– directly at the device via operating keys on the display

– via digital communication if the cover is not open

Note!

In hazardous areas, comply strictly with the safety instructions when the housing cover is closed and open.

• The local display can be rotated in 90° stages.

FMB50 Level measurement

• Always install the device below the lowest measuring point.

• Do not install the device at the following positions:

– in the filling curtain

– in the tank outflow

– or at a point in the tank that can be affected by pressure pulses from the agitator

• The calibration and functional test can be carried out more easily if you mount the device downstream of a

shutoff device.

• Deltapilot M must be included in the insulation for media that can harden when cold.

Pressure measurement in gases

• Mount Deltapilot M with shutoff device above the tapping point so that any condensate can flow into the

process.

Pressure measurement in steams

• Mount Deltapilot M with siphon below the tapping point.

• Fill the siphon with liquid before commissioning.

The siphon reduces the temperature to almost the ambient temperature.

Pressure measurement in liquids

• Mount Deltapilot M with the shutoff device below or at the same level as the tapping point.

FMB51/FMB52/FMB53 • When mounting rod and cable versions, make sure that the probe head is located at a point as free as possible

from flow. To protect the probe from impact resulting from lateral movement, mount the probe in a guide

tube (preferably made of plastic) or secure it with a clamping fixture.

• In the case of devices for hazardous areas, comply strictly with the safety instructions when the housing

cover is open.

• The length of the extension cable or the probe rod is based on the planned level zero point. The top of the

probe should be at least 5 cm (1.97 in) below this.

• Suspension clamp (FMB53 only)

Material: Edelstahl AISI 316L (1.4435), clamping jaw: fiberglass reinforced PA (polyamide)

Order number: 52010869

ä 43 ff, feature 620 , "Accessory enclosed", version "PO".

61

23

8

Page 19: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 19

Supplementary installation

instructions

Process isolating diaphragm

• Do not clean or touch process isolating diaphragms with hard or pointed objects.

• The process isolating diaphragm in the rod and cable version is protected against mechanical damage by a

plastic cap.

Seal

• Deltapilot M devices with a G 1 1/2 thread:

When screwing the device into the tank, the flat seal has to be positioned on the sealing surface of the process

connection. To avoid additional strain on the process isolating diaphragm, the thread should never be sealed

with hemp or similar materials.

• Deltapilot M devices with NPT threads:

– Wrap Teflon tape around the thread to seal it.

– Tighten the device at the hexagonal bolt only. Do not turn the device at the housing.

– Do not overtighten the thread when screwing in the screw. Max. torque: 20 to 30 Nm

(14.75 to 22.13 lbf ft)

Sealing the probe housing

Moisture must not penetrate the housing when mounting the device, establishing the electrical connection and

during operation.

• Always firmly tighten the housing cover and the cable entries.

• Lubricant is provided on the O-ring seal in the housing cover and on the thread of the aluminum cover. To

ensure that the cover seals tight, any lubricant which has been removed must be replaced. Use silicone

grease or graphite paste as the lubricant. Mineral oil-based grease can destroy the O-ring.

Cable length tollerances

• FMB52

– Cable length < 5 m (16 ft): up to -35 mm (-1.38 in)

– Cable length > 5 m (16 ft): up to -100 mm (-3.94 in)

– Cable length > 100 m (328 ft): up to -250 mm (-9,84 in)

• FMB53

– Cable length < 5 m (16 ft): up to ±17,5 mm (±0.69 in)

– Cable length > 5 m (16 ft): up to ±50 mm (±1.97 in)

– Cable length > 100 m (328 ft): up to ±125 mm (±4,92 in)

Rod length tollerances

• FMB51

– Rod length < 4000 mm (157 in): up to ±4 mm (±0,16 in)

Wall and pipe mounting Endress+Hauser offers a mounting bracket for installing the device on pipes or walls

ä 43 ff, feature 620, "Accessory enclosed", version "PA" or as seperate accessory (part no.: 71102216).

For the dimensions, ä 34.

Page 20: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

20 Endress+Hauser

"Separate housing" version With the "separate housing" version, you are able to mount the housing with the electronics insert at a distance

from the measuring point. This allows for trouble-free measurement:

• Under particularly difficult measuring conditions (at installation locations that are cramped or difficult to

access)

• If rapid cleaning of the measuring point is required

• If the measuring point is exposed to vibrations

You can choose between different cable versions:

• PE (2 m (6.6 ft), 5 m (16 ft) and 10 m (33 ft))

• FEP (5 m (16 ft)).

ä 43 ff, feature 600, "Separate housing".

For the dimensions, see ä 34.

P01-PMx5xxxx-11-xx-xx-en-002

In the case of the "separate housing" version, the sensor is delivered with the process connection and cable ready

mounted. The housing and a mounting bracket are enclosed as separate units. The cable is provided with a socket at both

ends. These sockets are simply connected to the housing and the sensor.

1 Process connection with sensor

2 Cable, both ends are fitted with a socket

3 Mounting bracket provided, suitable for pipe and wall mounting (for pipes with 2" diameter)

4 Housing with electronic insert

Degree of protection for the process connection and sensor when using:

• FEP cable:

– IP 69K

– IP 66/68 NEMA 4/6P

• PE cable:

– IP 66/68 NEMA 4/6P

Technical data of the PE and FEP cable:

• Minimum bending radius: 120 mm (4.72 in)

• Cable extraction force: max. 450 N (101 lbf)

• Resistance to UV light

Use in hazardous area:

• Intrinsically safe installations (Ex ia/IS)

• FM/CSA IS: for Div.1 installation only

Installation conditions

General conditions

• Installation without insulation

• Ambient temperature: max. 50°C (122°F)

➂➃

r � 120 mm

IP xx(see chapter“Ordering information”)

FEP cable:IP 69KIP 66/68 NEMA 4/6P

PE cable:IP 66/68 NEMA 4/6P

Page 21: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 21

Oxygen applications Oxygen and other gases can react explosively to oils, grease and plastics. As a result, the following are some of

the precautions that must be taken:

– All components of the system, such as measuring devices, must be cleaned in accordance with the BAM

(DIN 19247) requirements.

– Depending on the materials used, a certain maximum temperature and maximum pressure must not be

exceeded for oxygen applications. The maximum temperature Tmax for oxygen applications is 60°C (140°F).

The devices suitable for gaseous oxygen applications are listed in the following table with the specification pmax.

Silicone-free applications Special cleaning of the transmitter to remove paint-wetting substances, for use in paint shops ä 43 ff

feature 570 "Service", version "HC".

Applications with hydrogen With regard to materials in which hydrogen formation takes place (e.g. digested sludge), hydrogen atoms can

diffuse through the metal process isolating diaphragm. This can result in incorrect measurement results.

Endress+Hauser offers process isolating diaphragms with a gold/rhodium coating for such instances.

Order via feature 170 "Material of the process isolating diaphragm", version "L".

Note!

To reduce the formation of hydrogen, you should not use galvanized assemblies.

Special measuring cells for

acids, alkalis or sea water

(not FMB50)

For acids, alkalis or sea water, Endress+Hauser offers process isolating diaphragms with a gold/platinum

coating.

Note!

With temperature exposure (up to 85 °C (185 °F)) there is an additional zero point deviation of 1,1 mbar

(0,0165 psi).

Order via feature 170 "Material of the process isolating diaphragm", version "N".

Order code for devices1) cleaned

for oxygen applications

1) Only device, not accessory or enclosed accessory

pmax for oxygen applications

FMB50 2)

2) Feature 570 "Service" version "HB"

• Depends on the lowest-rated element, with regard to pressure, of the selected

components: over pressure limit (OPL) of the sensor or process connection (1.5

x PN) 3)

• Depends on filling oil 4)

3) ä 9, "Measuring range" section and ä 25 ff, "Mechanical construction" section

4) Oxygen applications possible with FKM seal and inert oil.

FMB51 ) • Depends on the lowest-rated element, with regard to pressure, of the selected

components: over pressure limit (OPL) of the sensor or process connection (1.5

x PN) )

• Depends on filling oil )

• Depends on seal material

Page 22: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

22 Endress+Hauser

Operating conditions (environment)

Ambient temperature range

Storage temperature range

Degree of protection • ä 43 ff, feature 50 "Electrical connection".

• Separate housing ä 20

Climate class Class 4K4H (air temperature: –20 to 55°C (–4 to +131°F), relative humidity: 4 to 100%) satisfied as per

DIN EN 60721-3-4 (condensation possible)

Vibration resistance

Electromagnetic compatibility • Electromagnetic compatibility as per all the relevant requirements of the EN 61326 series and NAMUR

Recommendation EMC (NE21). Details can be found in the Declaration of Conformity (in the Download

area of "www.de.endress.com", "search area - Approvals and Certificates", "Manufact. Declaration").

• Maximum deviation: < 0.5 % of the span to turn down (TD) = 2:1

• All measurements were performed with a turn down (TD) = 2:1.

Version FMB50 FMB51 FMB52 FMB53

Without LCD display –40°C to +85°C

(-40°F to +185°F)

With PE cable: -40°C to +70°C (-40°F to +158°F)

With FEP cable: –40°C to +80°C (-40°F to +176°F)

With LCD display 1)

1) Extended temperature application range (-40°C to +85°C (–40°F to +185°F)) with restrictions in optical properties

such as display speed and contrast

–20°C to +70°C (-4°F to +158°F)

With M12 plug , elbowed -25°C to +85°C

(-13°F to +185°F)

With PE cable: -25°C to +70°C (-13°F to +158°F)

With FEP cable: -25°C to +80°C (-13°F to +176°F)

With separate housing (PE

and FEP cable)

-20°C to +60 °C (-4°F to +140°F)

Version FMB50 FMB51 FMB52 FMB53

Without LCD display –40°C to +90°C

(-40°F to +194 °F) With PE cable: -40°C to +70°C (-40°F to +158°F)

With FEP cable: –40°C to +80°C (-40°F to +176°F)With LCD display –40°C to +85°C

(-40°F to +185°F)

With M12 plug , elbowed -25°C to +90°C

(-13°F to +194°F)

With PE cable: -25°C to +70°C (-13°F to +158°F)

With FEP cable: -25°C to +80°C (-13°F to +176°F)

With separate housing and

FEP cable

-20°C to +60°C (-4°F to +140°F)

Device/accessory Test standard Vibration resistance

FMB50 GL VI-7-2

• Part 7: Guidelines for the Performance of Type

Approvals

• Chapter 2: Test Requirements for Electrical /

Electronic Equipment and Systems

Guaranteed for:

3 to 25 Hz: ±1.6 mm (0.06 in);

25 to 100 Hz: 4 g

in all 3 planes

• FMB50

IEC 61298-3

IEC 60068-2-6

Guaranteed for:

10 to 60 Hz: ±0.15 mm (0.01 in);

60 to 500 Hz: 2 g

in all 3 planes

FMB51, FMB52, FMB53 Guaranteed for:

10 to Hz: 0,075 mm (0.003 in)

60...150 Hz 1g in all 3 planes

Page 23: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 23

Overvoltage protection

(optional)

The device can be fitted with overvoltage protection, see ä 43 ff "Ordering information" feature 610

"Accessory mounted:" version "NA". The overvoltage protection is mounted at the factory on the housing

thread (M20x1.5) for the cable gland and is approx. 70 mm (2.76 in) in length (take additional length into

account when installing). The device is connected as illustrated in the following graphic.

For details refer to TI103R/09/EN, XA036R/09/A3 and KA161R/09/A6.

Wiring

P01-xMx5xxxx-04-xx-xx-en-006

Unit to beprotected

Connectioncables

Incomingconnection cables

HAW569Z

+

-

+

-Red

Black

+

-

Shield grounding

without

direct

➀➁

Page 24: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

24 Endress+Hauser

Operating conditions (process)

Process temperature range

Lateral load FMB51 (static) 30 Nm

Pressure specifications • The maximum pressure for the measuring device depends on the lowest-rated element with regard to

pressure. See the following

sections:

– ä 9 ff, "Measuring range" section

– "Mechanical construction" section.

The MWP (maximum working pressure) is specified on the nameplate. This value refers to a reference

temperature of +20°C (68°F) or 100°F (38°C) for ANSI flanges and may be applied to the device for an

unlimited time. Pay attention to pressure-temperature dependencies.

• The pressure values permitted at higher temperatures can be found in the following standards:

– EN 1092-1: 2001 Tab. 18 1

– ASME B 16.5a – 1998 Tab. 2-2.2 F316

– ASME B 16.5a – 1998 Tab. 2.3.8 N10276

– JIS B 2220.

• The test pressure corresponds to the over pressure limit of the device (OPL = 1.5 x MWP) and may be applied

for only a limited time period in order to avoid permanent damage.

• The Pressure Equipment Directive (EC Directive 97/23/EC) uses the abbreviation "PS". The abbreviation

"PS" corresponds to the MWP (maximum working pressure) of the measuring device.

• In the case of sensor range and process connection combinations where the OPL (over pressure limit) of the

process connection is smaller than the nominal value of the sensor, the device is set at the factory, at the

very maximum, to the OPL value of the process connection. If you want to use the entire sensor range, select

a process connection with a higher OPL value (1.5 x PN; PN = MWP).

• In oxygen applications, the values for "pmax and Tmax for oxygen applications" as per ä 21, "Oxygen

applications" may not be exceeded.

FMB50 FMB51 FMB52 FMB53

–10°C to +100°C (+14°F to 212°F)

135°C (275°F) for 30 min. maximum

–10°C to +85°C

(+14°F to +185°F)

With PE cable: -10°C to +70°C (-14°F to 158°F)

With FEP cable: –10°C to +80°C (-14°F to 176°F)

1) With regard to their stability-temperature property, the materials 1.4435 and 1.4404 are grouped together under 13EO

in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical.

Page 25: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 25

Mechanical construction

F31 aluminum housing

dimensions

P01-F31xxxx-06-00-xx-xx-000

Front view, left-hand side view, top view

➀ The cover with viewing window is 15 mm (0,59 in) higher than the cover without viewing window.

For installation height H for housing with viewing window, see the specific process connection. Housing weight

ä 35

F15 stainless steel housing

dimensions (hygienic)

P01-F15xxxx-06-00-xx-xx-000

Front view, top view.

➀ The cover with viewing window is 19 mm (0,75 in) higher than the cover without viewing window.

For installation height H for housing with viewing window, see the specific process connection. Housing weight

ä 35

Process connections FMB50

(compact version)

Threaded connection ISO 228 and NPT

P01-FMB70xxx-06-09-xx-xx-004

For the installation height, see the following table. For weight, see ä 35.

1 Thread ISO 228 G 1 1/2 A;

Material version GGJ: AISI 316L/1.4435, version GGC: Alloy C276/2.4819

2 Thread ANSI 1 1/2 MNPT;

Material version RGJ: AISI 316L/1.4435

115

10

3

94

H

15

76

100

H

19

➀ G 1 1/2

H

➁ 1 1/2 NPTSW 5050 AF

H

ø55

G 1 1/2

ø55

25

ø55

G 1 1/2

ø55

25

1 1/2 NPT

ø55ø55

25

SW 5050 AF

Page 26: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

26 Endress+Hauser

Installation height H, devices with a thread

EN/DIN flanges, connection dimensions as per EN 1092-1/DIN 2527

P01-FMB70xxx-06-09-xx-xx-002

Flange with raised face

H: device height = height of device without flange h + flange thickness b

Height H, see ä 28.

F31 housing F15 housing

156 mm (6.14 in) 148 mm (5.83 in)

D

k

b

g2

g

H

2

h

Flange 1) Boltholes

Version Material 2) Nominal

diameter

Nominal

pressure

Shape 3)

Diameter Thick-

ness

Diameter

of raised

face

Height

of

raised

face

Quant-

ity

Diameter Hole

circle

Flange

weight 4)

D b g f g2 k

[mm] [mm] [mm] [mm] [mm] [mm] [kg]

CEJ AISI 316L DN 40 PN 10/16 B1 (C) 150 18 88 2 4 18 110 2.6

CFJ AISI 316L DN 50 PN 10/16 B1 (C) 165 18 102 2 4 18 125 3.3

CGJ AISI 316L DN 80 PN 10/16 B1 (C) 200 20 138 2 8 18 160 5.1

CHJ AISI 316L DN 100 PN 10/16 B1 (C) 220 20 158 2 8 18 180 6.3

1) The roughness of the surface in contact with the medium, including the sealing surface of the flanges, is Ra 0.8 μm (31,5 μin). Lower surface roughness

available on request.

2) AISI 316L

3) Designation as per DIN 2526 in brackets

4) Weight incl. pipe and measuring cell, housing weight, see ä 35

Page 27: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 27

ANSI flanges, connection dimensions as per ANSI B 16.5, raised face RF

P01-FMB70xxx-06-09-xx-xx-002

Flange with raised face

H: device height = height of device without flange h + flange thickness b

Height H, see ä 28.

D

k

b

g2

g

H

2

h

Flange 1) Boltholes

Version Material 2) Nominal

diameter

Class Dia-

meter

Thick-

ness

Diameter of

raised face

Height of

raised face

Quant-

ity

Diameter Hole

circle

Flange

weight 3)

D b g f g2 k

[in] [lb./sq in] [in]

[mm]

[in]

[mm]

[in]

[mm]

[in]

[mm]

[in]

[mm]

[in]

[mm]

[kg]

AEJ

Not FMB51/52

AISI 316/

316L

1 1/2 150 5

127

0.69

17.5

2.88

73.2

0.06

1.6

4 0.62

15.7

3.88

98.6

2.1

AFJ AISI 316/

316L

2 150 6

152.4

0.75

19.1

3.62

91.9

0.06

1.6

4 0.75

19.1

4.75

120.7

3.0

AGJ AISI 316/

316L

3 150 7.5

190.5

0.94

23.9

5

127

0.06

1.6

4 0.75

19.1

6

152.4

5.7

AHJ AISI 316/

316L

4 150 9

228.6

0.94

23.9

6.19

157.2

0.06

1.6

8 0.75

19.1

7.5

190.5

7.8

1) The roughness of the surface in contact with the medium, including the sealing surface of the flanges, is Ra 0.8 μm (31,5 μin). Lower surface roughness

available on request.

2) Combination of AISI 316 for required pressure resistance and AISI 316L for required chemical resistance (dual rated)

3) Weight incl. pipe and measuring cell, housing weight, see ä 35

Page 28: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

28 Endress+Hauser

JIS flanges, connection dimensions as per JIS B 2220 BL, raised face RF

P01-FMB70xxx-06-09-xx-xx-002

Flange with raised face

H: device height = height of device without flange + flange thickness b

Height H, see ä 28.

Installation height H, devices with flange

D

k

b

g2

g

H

2

h

Flange 1) Boltholes

Version Material Nominal

diameter

Nominal

pressure

Diameter Thickness Diameter

of raised

face

Height of

raised

face

Quantity Diameter Hole

circle

Flange

weight 2)

D b g f g2 k

[mm] [mm] [mm] [mm] [mm] [mm] [kg]

KEJ AISI 316L 40 A 10 K 140 16 81 2 4 19 105 2.1

KFJ AISI 316L 50 A 10 K 155 16 96 2 4 19 120 2.5

KGJ AISI 316L 80 A 10 K 185 18 126 2 8 19 150 3.8

KHJ AISI 316L 100 A 10 K 210 18 151 2 8 19 175 4.9

1) The roughness of the surface in contact with the medium, including the sealing surface of the flanges (all standards), is Ra 0.8 μm (31,5 μin). Lower surface

roughness available on request.

2) Weight incl. pipe and measuring cell, housing weight, see ä 35

F31 housing F15 housing

165 mm (6.5 in) 157 mm (6.18 in)

Page 29: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 29

Universal process adapter

P01-FMB70xxx-06-09-xx-xx-003

Material: AISI 316L/1.4435;

Surface roughness of the surfaces in contact with the medium Ra 0.8 m (6,18 in) as standard. Lower surface roughness

available on request.

1 Version UPJ: universal process adapter incl. silicone molded seal, EHEDG, 3A

Version UNJ: universal process adapter incl. EPDM molded seal, EHEDG, 3A

2 Version UQJ: universal process adapter, 6 inch extension including silicone molded seal, EHEDG, 3A

Version UOJ: universal process adapter, 6 inch extension including EPDM molded seal, EHEDG, 3A

Installation height H, devices with universal process adapter

Anderson process adapter

P01-FMBX0xxx-06-09-xx-xx-000

Material: AISI 316L/1.4435;

Surface roughness of the surfaces in contact with the medium Ra 0.8 m (31,5 μin) as standard. Lower surface roughness

available on request.

1 Version USJ: Anderson process adapter short 2-3/16", incl. silicone molded seal, 3A

2 Version UTJ: Anderson process adapter long 6-1/2", incl. silicone molded seal, 3A

Installation height H, devices with Anderson process adapter

➀ ➁

ø43.5

H

ø43.5

H

F31 housing F15 housing

Universal process adapter 196 mm (7.72 in) 189 mm (7.44 in)

Universal process adapter

with 6 inch extension

307 mm (12.1 in) 299 mm (11.8 in)

➀ ➁

H

ø2" ø2"

ø3"

ø3" H

F31 housing F15 housing

Anderson short 204 mm (8.03 in) 196 mm (7.72 in)

Anderson long 314 mm (12.4 in) 306 mm (12 in)

Page 30: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

30 Endress+Hauser

Hygienic connections

P01-FMB5xxxx-06-xx-xx-xx-001

Hygienic connections, material AISI 316L/1.4435

Surface roughness of the surfaces in contact with the medium Ra 0.8 m (31,5 μin) as standard. Lower surface roughness

available on request. For weight, see ä 35.

1 Version MZJ: DIN 11851 DN 40 PN 25, EHEDG , 3A

2 Version MRJ: DIN 11851 DN 50 PN 25, EHEDG , 3A

3 Version NDJ: DIN11864-1 A DN50 PN16 pipe DIN11866-A, threaded connection, 316L, EHEDG, 3A

4 Version TDJ: Tri-Clamp ISO 2852 DN 40 – DN 51 (2"), DIN 32676 DN 50, EHEDG1), 3A

5 Version TIJ: DRD DN50 (65 mm) PN 25, 316L

6 Version TRJ: Varivent Typ N for pipes 40 – 162, PN 40, EHEDG, 3A

7 Version TXJ: SMS 2", PN25, EHEDG , 3A2)

8 Version S4J: NEUMO, D50, PN16, 316L, 3A

Installation height H, devices with Tri-Clamp or hygienic connection

➄ Varivent N DN 40 – DN 162

Clamp ISO 2852 DN40 - DN 51 (2")/DIN 32676 DN 50

DRD DN50 (65 mm)

➀ DIN 11851 DN 40 ➁ DIN 11851 DN 50

4 x ø11.5

ø105

ø84

ø65–1.2

23

.5

H

H

ø64

ø56.5

20

.5

H

Rd 70 x1/6

ø65

ø84

ø56

Rd 65 x 1/6

10

.2

H

ø68.5

Rd 78 x 1/6

11

.2

H

SMS 2"

ø68

H

20

.5

ø84

➆ NEUMOø9

27

ø49.9

ø70

ø90

H

ø68.5

Rd 78 x 1/62

0,5

H

DIN 11864-1 A DN 50➂

1) Suitable fittings and seals must be used for hygienic design in accordance with EHEDG specifications.

2) Suitable fittings and seals must be used for hygienic design in accordance with 3A specifications.

F31 housing F15 housing

185 mm (7.28 in) 178 mm (7.01 in)

Page 31: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 31

Process connections FMB51

(rod version)

Threaded connection ISO 228 and NPT

P01-FMB51xxx-06-xx-xx-en-000

Rod version with thread G 1 1/2 or 1 1/2 NPT

L Probe length = 0.4 to 4 m (1.3 ft to 13 ft)

H For installation height H ä 26

For dimensions of process connections ä 25 ff.

EN/DIN, ANSI and JIS flanges

P01-FMB51xxx-06-xx-xx-xx-001

Rod version with flange

L Probe length = 0.4 to 4 m (1.3 ft to 13 ft)

H For installation height H ä 28

For dimensions of process connections ä 25 ff.

25

ø21.3

208

ø42.4

HL

AF50

g

ø21.3

ø42.4

g2

H

208

f

Dk

bL

Page 32: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

32 Endress+Hauser

Process connections FMB52

(cable version)

Threaded connection ISO 228 and NPT

P01-FMB52xxx-06-xx-xx-en-000

Cable version with thread G 1 1/2 and 1 1/2 NPT

L Probe length = 0.5 to 400 m (1.6 to 1312 ft)

H For installation height H ä 26

For dimensions of process connections ä 25 ff.

EN/DIN, ANSI and JIS flanges

P01-FMB52xxx-06-xx-xx-xx-001

Cable version with flange

L Probe length = 0.5 to 400 m (1.6 to 1312 ft)

H For installation height H ä 28

For dimensions of process connections ä 25 ff.

ø8

ø42.4 236

25

LHAF50

f

g2

b

H

k

D

g

ø8

236

L

ø42.4

Page 33: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 33

Dimensions of Deltapilot M

FMB53 (suspension clamp and

mounting bracket)

P01-FMB53xxx-06-xx-xx-xx-000

FMB53 with suspension clamp and mounting bracket

1 Mounting bracket for pipe and wall mounting (for pipes with 2" diameter)

2 Suspension clamp

3 Measuring cell tube

L Probe length = 0.5 to 400 m (1.6 to 1312 ft)

Dimensions (in mm)

ø42.4

23

6

61

23

8

ø8

L

Gø91

➀ ➀

A

ø91

F

EB

C D

R

200

mm

Pipe mounting Wall mounting

A [mm (in)] C [mm (in)] B [mm (in)] D [mm (in)]

Cover

flat

Cover

high

Cover

flat

Cover

high

Cover

flat

Cover

high

Cover

flat

Cover

high

F15 housing 154.7 (6.09) 173.7 (6.84) 197.1 (776) 210.6 (8.29) 167.7 (6.6) 186.7 (7.35) 210.1 (8.27) 223.6 (8.8)

F31 housing 167 (6.57) 181.3 (7.14) 211.8 (8.34) 221.7 (8.73) 180 (7.09) 194.3 (7.65) 224.8 (8.85) 234.7 (9.24)

E [mm (in)] F [mm (in)] G [mm (in)]

F15 housing 146 (5.75) 127 (5) 159 (6.26)

F31 housing 156.2 (6.15) 137.2 (5.4) 169.2 (6.66)

Page 34: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

34 Endress+Hauser

Wall and pipe mounting with

"Separate housing" version

P01-xMx5xxxx-06-xx-xx-xx-004

F31 housing dimensions. Housing weight ä 35. ➀ Cover without viewing window. ➁ Cover with viewing window.

F15 housing dimensions. Housing weight ä 35. ➂ Cover without viewing window. ➃ Cover with viewing window.

Reduction in installation height

If the separate housing is used, the mounting height of the process connection is reduced compared to the

dimensions of the standard version (see graphic).

P01-xMx5xxxx-06-xx-xx-xx-000

1 Process connection adapter.

A minimum bending radius (r) of 120 mm (4,72 in) must be observed for the cable.

FIE

LD

TE

RM

INA

LS

122

ø6

52

86

67

ø52

69

112 12

7➀➁

63

95 1

14➂

140

158 175

ø54.1

81

F15r � 120 mmr � 120 mm r � 120 mmr � 120 mmr � 120 mmr � 120 mm

➀➀➀

F31

29

44

17

36

Page 35: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 35

Example for a "Separate housing" version

P01-FMB5xxxx-06-xx-xx-xx-003

Connecting cable with process connection adapter and mounting bracket, here shown with an FMB52

1 Mounting bracket for pipe and wall mounting (for pipes with 2" diameter)

2 Process connection adapter

3 Measuring cell tube

L1 PE cable = 2 m (6.6 ft), 5m (16 ft) or 10 m (33 ft)

FEP cable = 5 m (16 ft)

L Probe length = 0.5 to 400 m (1.6 to 1312 ft)

Note!

For FMB50, FMB51, FMB52, order the separate housing via feature 600 "Separate housing" or subsequently

as an accessory.

Weight Housing

ø6

12

1.7

L1

L

R

120

mm

ø54.1

F31 housing F15 housing

Aluminum AISI 316L

With electronic insert

and local display

1.1 kg (2.43 lbs) 0.8 kg (1.76 lbs)

Page 36: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

36 Endress+Hauser

Separate housing

Note!

Total weight = weight of separate housing + weight cable + weight mounting bracket +

Pipe bend + weight process connection adapter + (see following chapters)

Process connections FMB50 or Process connection and pioe FMB51 or Process connection and cable FMB52

Process connections FMB50

Note!

Total weight of device = weight of housing ( ä 35) + weight of process connection FMB50

Process connection and pipe FMB51

Note!

• Total weight of device with threaded connection = weight of housing ( ä 35) + weight of pipe incl. cable

x length + weight of process connection FMB51

• Total weight of device with flange connection = weight of housing ( ä 35) + weight of pipe incl. cable x

length + weight of process connection FMB51

Designation Weight

Separate housing for FMB50 Weight of housing ( ä 35) + 0.5 kg (1.10 lbs).

Separate housing for FMB51 and FMB52 Weight of housing ( ä 35) + 0.65 kg (1.43 lbs).

Process connection adapter 0.4 kg (0.88 lbs)

Mounting bracket 0.2 kg (0.44 lbs)

Pipe bend incl. cable entry 0.65 kg (1.43 lbs)

PE cable 2 m (6,6 ft) 0.16 kg (0.35 lbs)

PE cable 5 m (16 ft) 0.32 kg (0.71 lbs)

PE cable 10 m (33 ft) 0.59 kg (1.30 lbs)

FEP cable 5 m (16 ft) 0.62 kg (1.37 lbs)

Process connection incl. sensor Weight

DIN 11851 DN 40 0.7 kg (1.54 lbs)

DIN 11851 DN 50 0.9 kg (1.98 lbs)

Tri-Clamp ISO 2852 DN 40 – DN 51 (2")/DIN 32676 DN 50 0.7 kg (1.54 lbs)

DRD DN50 (65 mm) 1.1 kg (2.43 lbs)

Varivent Typ N for pipes DN 40 – DN 162 1.0 kg (2.21 lbs)

SMS 2" 0.7 kg (1.54 lbs)

NEUMO D50 1.1 kg (2.43 lbs)

Universal process adapter 0.8 kg (1.76 lbs)

Universal process adapter with 6 inch extended diaphragm seal 1.7 kg (3.75 lbs)

Thread ISO228 G1 1/2A, AISI316L / 1.4435 0.8 kg (1.76 lbs)

Thread ISO228 G1 1/2A, Alloy C276 / 2.4819 0.8 kg (1.76 lbs)

Thread ANSI 1 1/2 MNPT, AISI316L / 1.4435 0.8 kg (1.76 lbs)

Flange connection, incl. sensor, without a flange 0.45 kg (0.99 lbs)

Process connection incl. sensor Weight

Pipe incl. cable 0.77 kg/m (1.70 lbs/3.3 ft)

Threaded connection incl. measuring cell tube and sensor 1.65 kg (3.64 lbs)

Flange connection incl. measuring cell tube and sensor, without a flange 1.3 kg (2.87 lbs)

Page 37: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 37

Process connection and cable FMB52

Note!

• Total weight of device with threaded connection = weight of housing ( ä 35) + weight of cable x length

+ weight of process connection FMB52

• Total weight of device with flange connection = weight of housing ( ä 35) + weight of pipe incl. cable x

length + weight of process connection FMB52 + weight of flange ( ä 26 ff)

Process connection FMB53 – secured with suspension clamp and mounting bracket

Note!

Total weight of device = weight of housing ( ä 35) + weight of cable x length + weight of mounting bracket

+ weight of pipe bend + weight of suspension clamp + weight of measuring cell tube

Material F31 housing:

• F31 housing, optionally:

– Die-cast aluminum with protective powder-coating on polyester base: RAL 5012 (blue),

cover: RAL 7035 (gray)

• Sight glass: mineral glass

• Cable gland M20 x 1.5: polyamide (PA) or CuZn nickel-plated

• Pressure compensation filter: PA6 GF10

• Cable entry blind plug:

– G ½": PBT-GF30 FR, for Dust Ex, Ex d, FM XP and CSA XP: AISI 316L (1.4435)

– NPT ½": PBT-GF30 FR, for Dust Ex, Ex d, FM XP and CSA XP: AISI 316L (1.4435)

• Seals:

– Cable gland and blind plug: EPDM

– Pressure compensation filter O-ring: silicone (VMQ)

– Cover: EPDM

– Sight glass: silicone (VMQ)

• Nameplates: plastic

F15 housing:

• Housing and cover: stainless steel AISI 316L (1.4404)

• Sight glass:

– Version for non-hazardous areas, ATEX Ex ia, NEPSI Zone 0/1 Ex ia, IECEx Zone 0/1 Ex ia, FM NI, FM

IS, CSA IS: polycarbonate (PC)

– ATEX 1/2 D, ATEX 1/3 D, ATEX 1 GD, ATEX 1/2 GD, ATEX 3 G, FM DIP, CSA Dust Ex: mineral glass

• Cable gland M20 x 1.5: polyamide PA, for Dust-Ex: CuZn nickel-plated

• Pressure compensation filter: PA6 GF10

• Blind plug: PBT-GF30 FR, for Dust Ex: AISI 316L (1.4435)

• Seals:

– Cable gland and blind plug: NBR

– Pressure compensation filter O-ring: silicone (VMQ)

– Cover: silicone with PTFE coating

– Sight glass: silicone (VMQ)

Process connection incl. sensor Weight

PE cable 0.13 kg/m (0.28 lbs/3.3 ft)

FEP cable 0.18 kg/m (0.40 lbs/3.3 ft)

Threaded connection incl. measuring cell tube and sensor 1.65 kg (3.64 lbs)

Flange connection incl. measuring cell tube and sensor, without a flange 1.3 kg (2.87 lbs)

Process connection incl. sensor Weight

PE cable 0.13 kg/m (0.28 lbs/3.3 ft)

FEP cable 0.18 kg/m (0.40 lbs/3.3 ft)

Mounting bracket 0.2 kg (0.44 lbs)

Pipe bend incl. cable entry 0.65 kg (1.43 lbs)

Suspension clamp 0.4 kg (0.88 lbs)

Measuring cell tube incl. sensor 1.0 kg (2.21 lbs)

Page 38: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

38 Endress+Hauser

• Nameplates: lasered

DIN/EN flanges

Endress+Hauser supplies DIN/EN flanges made of stainless steel AISI 316L as per material numbers 1.4435

or 1.4404. With regard to their stability-temperature property, the materials 1.4435 and 1.4404 are grouped

together under 13EO in EN 1092-1 Tab. 18. The chemical composition of the two materials can be identical.

Seals

• For universal process adapter 44

mm: silicone molded seal FDA 21CFR177.2600/USP Class VI.

EPDM molded seal, 3A, EHEDG.

• FKM

• EPDM

• Kalrez 6375

Separate housing

• Process connection adapter: AISI 316L (1.4404)

• Housing adapter:

– FMB50, FMB51, FMB52: AISI 316L (1.4404)

– FMB53: AISI 304 (1.4301)

Cable gland: CuZn nickel-plated

– Sealing insert: TPE-V

– O-ring: NBR

• Cable:

– PE cable:

Abrasion-proof cable with strain-relief Dynema members; shielded using aluminum-coated foil; insulated

with polyethylene (PE-LD), black; copper wires, twisted, UV-resistant

– FEP cable:

Abrasion-proof cable; shielded using galvanized steel wire mesh; insulated with fluorinated ethylene

propylene (FEP), black; copper wires, twisted, UV-resistant

– O-ring: FKM, EPDM

– Cable socket: AISI 316L (1.4404)

– Bolts: A2

TSE Certificate of Suitability

The following applies to all process wetted device components:

• They do not contain any materials derived from animals.

• No auxiliaries or operating materials derived from animals are used in production or processing.

Note!

The wetted device components are listed in the "Mechanical construction" ( ä 25 ff) and "Ordering

information" ( ä 43 ff) sections.

Miscellaneous:

• Mounting accessories: mounting bracket AISI 304 (1.4301)

• Process isolating diaphragm: Alloy C276 (2.4819), Ø 35.8 mm (1.41 in)

• Filling oil

– Synthetic oil polyalphaolefin FDA 21 CFR 172.882

– Inert oil

For process connections and filling oils, see ordering information, ä 43 ff.

Page 39: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 39

Human interface

Local operation Local display (optional)

A 4-line liquid crystal display (LCD) is used for display and operation. The local display shows measured values,

dialog texts as well as fault and notice messages in plain text, thereby supporting the user at every stage of

operation. The liquid crystal display of the device can be turned in 90° stages.

Depending on the orientation of the device, this makes it easy to operate the device and read the measured

values.

Functions:

• 8-digit measured value display including sign and decimal point, bar graph for 4 to 20 mA HART as current

display

• Three keys for operation

• Simple and complete menu guidance as parameters are split into several levels and groups

• Each parameter is given a 3-digit ID number for easy navigation

• Possibility of configuring the display to suit individual requirements and preferences, such as language,

alternating display, contrast setting, display of other measured values such as sensor temperature etc.

• Comprehensive diagnostic functions (fault and warning message etc.)

P01-Mxxxxxxx-07-xx-xx-xx-002

E+–

Symbol

Operating keys

ValueDevice tag

Measured value display

Unit

Bargraph

Operating menu

Parameter with selection list

Freely editable parameter

DirectAccessCode

Value thatcan beedited

Selectionoptions

Header line

Informationline

Main line

Page 40: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

40 Endress+Hauser

Operating keys and elements located on the electronic insert

Functions of the local display and the operating keys and operating elements on the electronic

insert

• Position adjustment (zero point correction)

• Setting lower range value and upper range value - reference pressure present at the device

• Device reset

• Locking and unlocking parameters relevant to the measured value

• Switching damping on and off

• Value acceptance indicated by the green LED (not visible if display attached)

P01-Mxxxxxxx-19-xx-xx-xx-001

HART electronic insert

1 DIP switch for locking/unlocking parameters

relevant to the measured value

2 DIP switch for switching damping on/off

3 DIP switch for alarm current SW / Alarm Min

(3.6 mA)

4 DIP switch only for Deltabar M

5 Slot for optional local display

6 Green LED to indicate successful operation

7 Operating keys for lower range value (zero)

and upper range value (span)

➂➁

on

off

SW

/ P

2=

Hig

h

SW

/A

larm

min

SW

/�

dam

pin

g

1 2 3 4 5

➆ on

off

DisplayZero

Span

SW

/ P

2=

Hig

h

de

lta

p o

nly

SW

/A

larm

min

SW

/�

da

mp

ing

Page 41: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 41

Remote operation All software parameters are accessible depending on the position of the write protection switch on the device.

HART

Remote operation via:

• Field Communicator 375 handheld terminal. Use the handheld terminal to set all parameters all along the

bus cable via menu operation.

• Field Xpert. Field Xpert is an industrial PDA with integrated 3.5" touchscreen from Endress+Hauser based

on Windows Mobile. It communicates via wireless with the optional VIATOR Bluetooth modem connected

to a HART device point-to-point or wireless via WiFi and Endress+Hauser’s Fieldgate FXA520. Field Xpert

also works as a stand-alone device for asset management applications. For details refer to BA060S/00/EN.

• FieldCare. FieldCare is an Endress+Hauser asset management tool based on FDT technology. With

FieldCare, you can configure all Endress+Hauser devices.

– FieldCare supports the following functions:

– Configuration of transmitters in offline and online mode

– Loading and saving device data (upload/download)

– Documentation of the measuring point

– Connection options:

– By means of the Commubox FXA191 for intrinsically safe HART communication with FieldCare via the

RS232C interface of a computer. For details refer to TI237F/00/EN.

– By means of the Commubox FXA195 for intrinsically safe HART communication with FieldCare via the

USB port of a computer. For details refer to TI404F/00/EN.

P01-xMx5xxxx-04-xx-xx-xx-009

1 PLC

2 Resistor for HART communication

3 VIATOR Bluetooth Modem with connection cable

4 Field Xpert (Industrial PDA)

5 Screening

6 Commubox FXA191 (RS232), FXA195 (USB)

7 Handheld terminal DXR375/FC375

8 Transmitter power supply unit RMA422 or RN221N (with integrated communication resistor)

9 Conection for:

- Commubox FXA191 (RS232), FXA195 (USB)

- Handheld terminal DXR375/FC375

Note!

For further information please contact your local Endress+Hauser Sales Center.

+

3

6

4...20 mA� �250

5

ENDRESS + HAUSERRMA 422

FieldCare

8

79

1

2

4

Page 42: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

42 Endress+Hauser

Certificates and approvals

CE mark The device meets the legal requirements of the relevant EC directives.

Endress+Hauser confirms that the device has been successfully tested by applying the CE mark.

Ex approvals • ATEX

• FM

• CSA

• Also combinations of different approvals

All explosion protection data are given in separate documentation which is available upon request. The Ex

documentation is supplied as standard with all devices approved for use in explosion hazardous areas.

ä 56 ff, "Safety Instructions" and "Installation/Control Drawings" sections.

Suitability for hygienic

processes

Standards and guidelines DIN EN 60770 (IEC 60770):

Transmitters for use in industrial process control systems

Part 1: Methods for inspection and routine testing

DIN 16086:

Electrical pressure measuring instruments, pressure sensors, pressure transmitters, pressure measuring

instruments,

concepts, specifications on data sheets

EN 61326 series:

EMC product family standard for electrical equipment for measurement, control and laboratory use.

Pressure Equipment Directive

(PED)

The Deltapilot M device corresponds to Article 3 (3) of the EC directive 97/23/EC (Pressure Equipment

Directive) and has been designed and manufactured according to good engineering practice.

Drinking water approval • KTW certificate

• NSF 61 approval

• ACS approval

The Deltapilot M is suitable for use in hygienic processes.

Overview of permitted process connections from ä 25.

Many versions meet the requirements of 3A-Sanitary Standard No. 74 and

are certified by the EHEDG (pending).

Note!

Gap-free connections can be cleaned

without residue using the usual cleaning methods.

74 -74 -

Page 43: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 43

Ordering information

FMB50 This overview does not mark options which are mutually exclusive.

10 Approval:

AA For non-hazardous areas

BA ATEX II 1/2G Ex ia IIC T6

BB ATEX II 1/2D Ex t IIIC

BD ATEX II 3G Ex nA IIC T6

BE ATEX II 2G Ex ia IIC T6

B1 ATEX II 1/2G Ex ia IIC T6 + ATEX II 1/2D, Ex iaD

IA IEC Ex ia IIC T6 Ga/Gb

ID IEC Ex t IIIC Da/Db

IE IEC Ex ic IIC T6 Gc

I1 IEC Ex ia IIC T6 Ga/Gb+Ex ia IIIC Da/Db

CA CSA C/US IS Cl.I,II,III Div.1 Gr.A-G,

CSA C/US IS Cl.I Div.2 Gr.A-D, Ex ia,

C: Zone 0,1,2/US: Zone 0,1,2,20,21,22

CC CSA C/US Cl.II, III Div.1 Gr.E-G, US: Zone 21,22

CD CSA General Purpose

FA FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia,

FM NI Cl.I Div.2 Gr.A-D

FM IS: zone 0,1,2,20,21,22/FM NI: zone 2

FC FM DIP Cl.II, III Div.1 Gr.E-G, zone 21,22

FD FM NI Cl.I Div.2 Gr.A-D

99 Special version

20 Output:

2 4-20mA HART

9 Special version

30 Display, operation

1 LCD, push buttons

2 W/o LCD, push buttons

9 Special version

40 Housing:

I F31 aluminum

J F31 aluminum, glass window

Q F15 stainless steel Hygiene

R F15 stainless steel Hygiene, glass, window

S F15 stainless steel Hygiene, plastic, window

Y Special version

50 Electrical connection:

A Gland M20, IP66/68 NEMA4X/6P

C Thread G1/2, IP66/68 NEMA4X/6P

D Thread NPT1/2, IP66/68 NEMA4X/6P

I Connector M12, IP66/68, NEMA4X/6P

M Connector 7/8", IP66/68, NEMA4X/6P

P Connector Han7D, 90deg, IP65

S Cable 5m, IP66/68 NEMA4X/6P + pressure compensation via cable

V Valve connector ISO4400 M16, IP64

Y Special version

70 Sensor range:

1C 100mbar/10kPa/1.5psi relative, 1mH2O/3ftH2O/40inH2O

Overload: 4bar/400kPa/60psi

1F 400mbar/40kPa/6psi relative, 4mH2O/13ftH2O/160inH2O

Overload: 8bar/800kPa/120psi

1H 1.2bar/120kPa/18psi relative, 12mH2O/40ftH2O/480inH2O

Overload: 24bar/2.4MPa/350psi

1M 4bar/400kPa/60psi relative, 40mH2O/133ftH2O/1600inH2O

Overload: 24bar/2.4MPa/350psi

1P 10bar/1MPa/150psi relative, 100mH2O/333ftH2O/4000inH2O

Overload: 40bar/4MPa/600psi

99 Special version

80 Reference accuracy:

D Platinum

G Standard

Y Special version

Page 44: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

44 Endress+Hauser

FMB50 (continued) 90 Calibration; Unit:

A Sensor range; %

B Sensor range; mbar/bar

C Sensor range; kPa/MPa

D Sensor range; mm/mH2O

E Sensor range; inH2O/ftH2O

F Sensor range; psi

J Customized pressure; see additional spec.

K Customized level; see additional spec.

Y Special version

110 Process connection:

Threaded connection

GGC Thread ISO228 G1-1/2, AlloyC

GGJ Thread ISO228 G1-1/2, 316L

RGJ Thread ANSI MNPT1-1/2, 316L

ANSI flanges

AEJ 1-1/2" 150lbs RF, 316/316L, flange ANSI B16.5

AFJ 2" 150lbs RF, 316/316L, flange ANSI B16.5

AGJ 3" 150lbs RF, 316/316L, flange ANSI B16.5

AHJ 4" 150lbs RF, 316/316L, flange ANSI B16.5

EN flanges

CEJ DN40 PN10/16 B1, 316L, flange EN1092-1

CFJ DN50 PN10/16 B1, 316L, flange EN1092-1

CGJ DN80 PN10/16 B1, 316L, flange EN1092-1

CHJ DN100 PN10/16 B1, 316L, flange EN1092-1

JIS flanges

KEJ 10K 40 RF, 316L, flange JIS B2220

KFJ 10K 50 RF, 316L, flange JIS B2220

KGJ 10K 80 RF, 316L, flange JIS B2220

KHJ 10K 100 RF, 316L, flange JIS B2220

Hygienic connections

MRJ DIN11851 DN50 PN25 cap-nut, 316L, EHEDG, 3A

MZJ DIN11851 DN40 PN25 cap-nut, 316L, EHEDG, 3A

NDJ DIN11864-1 A DN50 PN16 tube DIN11866-A, threaded connection, 316L, EHEDG, 3A

S4J NEUMO BioControl D50 PN16, 316L, 3A

TXJ SMS 2" PN25, 316L, EHEDG, 3A1)

1) Suitable fittings and seals must be used for hygienic design in accordance with 3A specifications.

TIJ DRD DN50 65mm PN25, 316L

TRJ Varivent N pipe DN40-162 PN40, 316L, EHEDG, 3A

UNJ Universal adapter 316L, EPDM molded seal, 3A, EHEDG

UOJ Universal adapter 316L, 6" ext., EPDM molded seal, 3A, EHEDG

UPJ Universal adapter 44mm 316L, 3A, EHEDG, incl. silicone molded seal

UQJ Universal adapter 44mm 316L, ext. 6",3A, EHEDG, incl. silicone molded seal

USJ Anderson short 2-3/16", 316L, 3A, incl. silicone seal

UTJ Anderson long 6-1/2", 316L, 3A, incl. silicone seal

Clamp connections

TDJ Tri-Clamp ISO2852 DN40-51 (2"), 316L, DIN32676 DN50, EHEDG2), 3A

2) Suitable fittings and seals must be used for hygienic design in accordance with EHEDG specifications.

YYY Special version

170 Material of the process isolating diaphragm:

B AlloyC

L Rhodium>gold>AlloyC

Y Special version

180 Fill fluid:

2 Inert oil

3 Synthetic oil, FDA

9 Special version

190 Seal:

U None, welded cell

Page 45: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 45

FMB50 (continued) Additional ordering information (optional)

500 Operating language:

AA English

AB German

AC French

AD Spanish

AE Italian

AF Dutch

AK Chinese

AL Japanese

550 Calibration:

F1 Factory calibration certificate, 5-point

F2 DKD calibration certificate 10-point

570 Service:

HA Oil and grease removed 1)

1) Only device, not accessory or enclosed accessory

HB Cleaned for oxygen service )

HC Cleaned for silicone-free applications )

HK Surface quality Ra<0.38um electropolished (wetted)

IA Configured min alarm current

IB Configured HART Burst Mode PV

I9 Special version

580 Test, certificate:

JA EN10204-3.1 wetted material, inspection certificate

JB NACE MR0175 wetted

JF AD2000 pressurized

KB EN10204-3.1 wetted material + Ra, (Ra= surface roughness), dimensional check, inspection certificate

KD EN10204-3.1 helium leak test, inspection certificate

KE EN10204-3.1 pressure test, inspection certificate

KF EN10204-3.1 measurement Delta ferrite content, inspection certificate

KG EN10204-3.1 PMI test (PMI = positive material identification), inspection certificate

K9 Special version

590 Other approvals:

LW CoC Certificate of Compliance

600 Separate housing:

MA Cable PE, 2m/80inch + housing mounting bracket, wall/pipe, 304

MB Cable PE, 5m/200inch + housing mounting bracket, wall/pipe, 304

MC Cable PE, 10m/400inch + housing mounting bracket, wall/pipe, 304

MH Cable FEP, 5m/200inch IP69K + housing mounting bracket, wall/pipe, 304

610 Accessory mounted:

NA Overvoltage protection

Page 46: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

46 Endress+Hauser

FMB50 (continued)

You can enter the versions for the specific feature in the following table. The versions entered make up the

complete order code.

620 Accessory enclosed:

QJ Welding neck G1-1/2, 316L

QK Welding neck G1-1/2, 316L, 3.1, EN10204-3.1 material, inspection certificate

QL Weld-in tool adapter G1-1/2, brass

QP Welding flange DRD DN50 65mm, 316L

QR Welding fl. DRD DN50 65mm, 316L 3.1, EN10204-3.1 material, inspection certificate

QS Weld-in tool flange DRD DN50 65mm, brass

QT Welding neck Uni D65, 316L

QU Welding neck Uni D65, 316L, 3.1, EN10204-3.1 material, inspection certificate

Q1 Weld-in tool adapter Uni D65, brass

Q2 Welding neck Uni D85, 316L

Q3 Welding neck Uni D85, 316L, 3.1, EN10204-3.1 material, inspection certificate

Q5 Welding neck Uni 6" D65, 316L

Q6 Welding neck Uni 6" D65, 316L, 3.1, EN10204-3.1 material, inspection certificate

Q7 Weld-in tool adapter Uni 6" D65, brass

RA Adapter Uni > DIN11851 DN40, 316L, slotted nut

R1 Adapter Uni > DIN11851 DN40, 316L, 3.1, slotted nut, EN10204-3.1 material, inspection certificate

RB Adapter Uni > DIN11851 DN50, 316L, slotted nut

R2 Adapter Uni > DIN11851 DN50, 316L, 3.1, slotted nut, EN10204-3.1 material, inspection certificate

RC Adapter Uni > DRD DN50 65mm, 316L

R3 Adapter Uni > DRD DN50 65mm, 316L, 3.1, EN10201-3.1 material, inspection certificate

RD Adapter Uni > Clamp 2", 316L

R4 Adapter Uni > Clamp 2", 316L, 3.1, EN10201-3.1 material, inspection certificate

RF Adapter Uni > Varivent, 316L

R5 Adapter Uni > Varivent, 316L, 3.1, EN10201-3.1 material, inspection certificate

RL Plug-in jack M12

RM Plug-in jack M12, 90deg

RN Plug-in jack M12, 90deg+5m cable

850 Firmware version:

78 01.00.zz, HART, DevRev01

895 Identification:

Z1 Measuring point (TAG)

Z2 Bus address

10 20 30 40 50 70 80 90 110 170 180 190 500 550 570 580 590 600 610 620 850 895

FMB50 -

Page 47: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 47

FMB51 This overview does not mark options which are mutually exclusive.

10 Approval:

AA For non-hazardous areas

BA ATEX II 1/2G Ex ia IIC T6

BB ATEX II 1/2D Ex t IIIC

BD ATEX II 3G Ex nA IIC T6

BE ATEX II 2G Ex ia IIC T6

B1 ATEX II 1/2G Ex ia IIC T6 + ATEX II 1/2D, Ex iaD

IA IEC Ex ia IIC T6 Ga/Gb

ID IEC Ex t IIIC Da/Db

IE IEC Ex ic IIC T6 Gc

I1 IEC Ex ia IIC T6 Ga/Gb+Ex ia IIIC Da/Db

CA CSA C/US IS Cl.I,II,III Div.1 Gr.A-G,

C/US IS Cl. I Div.2 Gr. A-D, Ex ia

C: zone 0,1,2/US: zone 0,1,2,20,21,22

CC CSA C/US Cl.II, III Div.1 Gr.E-G

US: zone 21,22

CD CSA General Purpose

FA FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia,

FM NI Cl.I Div.2 Gr.A-D

FM IS: Zone 0,1,2,20,21,22/FM NI: Zone 2

FC FM DIP Cl.II, III Div.1 Gr.E-G, zone 21,22

FD FM NI Cl.I Div.2 Gr. A-D, zone 2

99 Special version

20 Output:

2 4-20mA HART

9 Special version

30 Display, operation:

1 LCD, push buttons

2 W/o LCD, push buttons

9 Special version

40 Housing:

I F31 aluminum

J F31 aluminum, glass window

Q F15 stainless steel Hygiene

R F15 stainless steel Hygiene, glass window

S F15 stainless steel Hygiene, plastic window

Y Special version

50 Electrical connection:

A Gland M20, IP66/68 NEMA4X/6P

C Thread G1/2, IP66/68 NEMA4X/6P

D Thread NPT1/2, IP66/68 NEMA4X/6P

I Connector M12, IP66/68, NEMA4X/6P

M Connector 7/8", IP66/68, NEMA4X/6P

P Connector Han7D, 90deg, IP65

V Valve connector ISO4400 M16, IP64

Y Special version

70 Sensor range:

1C 100mbar/10kPa/1.5psi relative, 1mH2O/3ftH2O/40inH2O

Overload: 4bar/400kPa/60psi

1F 400mbar/40kPa/6psi relative, 4mH2O/13ftH2O/160inH2O

Overload: 8bar/800kPa/120psi

1H 1.2bar/120kPa/18psi relative, 12mH2O/40ftH2O/480inH2O

Overload: 25bar/2.5MPa/375psi

1M 4bar/400kPa/60psi relative, 40mH2O/133ftH2O/1600inH2O

Overload: 25bar/2.5MPa/375psi

1P 10bar/1MPa/150psi relative, 100mH2O/333ftH2O/4000inH2O

Overload: 40bar/4MPa/600psi

99 Special version

80 Reference accuracy:

D Platinum

G Standard

Y Special version

Page 48: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

48 Endress+Hauser

FMB51 (continued) 90 Calibration; Unit:

A Sensor range; %

B Sensor range; mbar/bar

C Sensor range; kPa/MPa

D Sensor range; mm/mH2O

E Sensor range; inH2O/ftH2O

F Sensor range; psi

J Customized pressure; see additional spec.

K Customized level; see additional spec.

Y Special version

100 Probe connection:

80 ..... mm rod, 316L 400...4000 mm

81 ..... mm rod, AlloyC 400...4000 mm

85 ..... in rod, 316L 16...160 inch

86 ..... in rod, AlloyC 16...160 inch

99 Special version

110 Process connection:

Threaded connection

GGC Thread ISO228 G1-1/2, AlloyC

GGJ Thread ISO228 G1-1/2, 316L

RGJ Thread ANSI MNPT1-1/2, 316L

ANSI flanges

AFJ 2" 150lbs RF, 316/316L, flange ANSI B16.5

AGJ 3" 150lbs RF, 316/316L, flange ANSI B16.5

AHJ 4" 150lbs RF, 316/316L, flange ANSI B16.5

EN flanges

CEJ DN40 PN10/16 B1, 316L, flange EN1092-1

CFJ DN50 PN10/16 B1, 316L, flange EN1092-1

CGJ DN80 PN10/16 B1, 316L, flange EN1092-1

CHJ DN100 PN10/16 B1, 316L, flange EN1092-1

JIS flanges

KEJ 10K 40 RF, 316L, flange JIS B2220

KFJ 10K 50 RF, 316L, flange JIS B2220

KGJ 10K 80 RF, 316L, flange JIS B2220

KHJ 10K 100 RF, 316L, flange JIS B2220

YYY Special version

170 Material of the process isolating diaphragm:

B AlloyC

L Rhodium>gold>AlloyC

N Platinum>gold>AlloyC

Y Special version

180 Fill fluid:

2 Inert oil

3 Synthetic oil, FDA

9 Special version

190 Seal:

A FKM Viton

J EPDM

L Kalrez 6375

U None, welded cell

Page 49: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 49

FMB51 (continued) Additional ordering information (optional)

You can enter the versions for the specific feature in the following table. The versions entered make up the

complete order code.

500 Operating language:

AA English

AB German

AC French

AD Spanish

AE Italian

AF Dutch

AK Chinese

AL Japanese

550 Calibration:

F1 Factory calibration certificate, 5-point

570 Service:

HA Oil and grease removed 1)

1) Only device, not accessory or enclosed accessory

HB Cleaned for oxygen service )

HC Cleaned for silicone-free applications )

IA Configured min alarm current

IB Configured HART Burst Mode PV

I9 Special version

580 Test, certificate:

JA EN10204-3.1 wetted material, inspection certificate

JB NACE MR0175 wetted

KD EN10204-3.1 helium leak test, inspection certificate

KE EN10204-3.1 pressure test, inspection certificate

KG EN10204-3.1 PMI test (PMI = positive material identification), inspection certificate

K9 Special version

600 Separate housing:

MA Cable PE, 2m/80inch + housing mounting bracket, wall/pipe, 304

MB Cable PE, 5m/200inch + housing mounting bracket, wall/pipe, 304

MC Cable PE, 10m/400inch + housing mounting bracket, wall/pipe, 304

MH Cable FEP, 5m/200inch IP69K + housing mounting bracket, wall/pipe, 304

610 Accessory mounted:

NA Overvoltage protection

620 Accessory enclosed:

QJ Welding neck G1-1/2, 316L

QK Welding neck G1-1/2, 316L, 3.1, EN10204-3.1 material, inspection certificate

QL Weld-in tool adapter G1-1/2, brass

RL Plug-in jack M12

RM Plug-in jack M12, 90deg

RN Plug-in jack M12, 90deg+5m cable

850 Firmware version:

78 01.00.zz, HART, DevRev01

895 Identification:

Z1 Measuring point (TAG)

Z2 Bus address

10 20 30 40 50 70 80 90 100 110 170 180 190 500 550 570 580 600 610 620 850 895

FMB51 -

Page 50: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

50 Endress+Hauser

FMB52 This overview does not mark options which are mutually exclusive.

10 Approval:

AA For non-hazardous areas

BA ATEX II 1/2G Ex ia IIC T6

BD ATEX II 3G Ex nA IIC T6

BE ATEX II 2G Ex ia IIC T6

IA IEC Ex ia IIC T6 Ga/Gb

IC IEC Ex ia IIC T6 Gb

IE IEC Ex ic IIC T6 Gc

CA CSA C/US IS Cl. I, II, III Div.1 Gr. A-G,

CSA C/US IS Cl. I Div. 2 Gr. A-D, Ex ia

C: Zone 0,1,2/US: Zone 0,1,20,21,22

CD CSA General Purpose

FE FM IS Cl.I Div.1 Gr.A-D, AEx ia, Zone 0,1,2

99 Special version

20 Output:

2 4-20mA HART

9 Special version

30 Display, operation:

1 LCD, push buttons

2 W/o LCD, push buttons

9 Special version

40 Housing:

I F31 aluminum

J F31 aluminum, glass window

Q F15 stainless steel Hygiene

R F15 stainless steel Hygiene, glass window

S F15 stainless steel Hygiene, plastic window

Y Special version

50 Electrical connection:

A Gland M20, IP66/68 NEMA4X/6P

C Thread G1/2, IP66/68 NEMA4X/6P

D Thread NPT1/2, IP66/68 NEMA4X/6P

I Connector M12, IP66/68, NEMA4X/6P

M Connector 7/8", IP66/68, NEMA4X/6P

P Connector Han7D, 90deg, IP65

V Valve connector ISO4400 M16, IP64

Y Special version

70 Sensor range:

1C 100mbar/10kPa/1.5psi relative, 1mH2O/3ftH2O/40inH2O

Overload: 4bar/400kPa/60psi

1F 400mbar/40kPa/6psi relative, 4mH2O/13ftH2O/160inH2O

Overload: 8bar/800kPa/120psi

1H 1.2bar/120kPa/18psi relative, 12mH2O/40ftH2O/480inH2O

Overload: 25bar/2.5MPa/375psi

1M 4bar/400kPa/60psi relative, 40mH2O/133ftH2O/1600inH2O

Overload: 25bar/2.5MPa/375psi

1P 10bar/1MPa/150psi relative, 100mH2O/333ftH2O/4000inH2O

Overload: 40bar/4MPa/600psi

99 Special version

80 Reference accuracy:

D Platinum

G Standard

Y Special version

90 Calibration; Unit:

A Sensor range; %

B Sensor range; mbar/bar

C Sensor range; kPa/MPa

D Sensor range; mm/mH2O

E Sensor range; inH2O/ftH2O

F Sensor range; psi

J Customized pressure; see additional spec.

K Customized level; see additional spec.

Y Special version

Page 51: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 51

FMB52 (continued) 100 Probe connection:

15 ..... mm cable, PE 500...400.000 mm

25 ..... in cable, PE 500...400.000 mm

35 ..... mm cable, FEP 20...15748 inch

45 ..... in cable, FEP 20...15748 inch

99 Special version

110 Process connection:

Threaded connection

GGC Thread ISO228 G1-1/2, AlloyC

GGJ Thread ISO228 G1-1/2, 316L

RGJ Thread ANSI MNPT1-1/2, 316L

ANSI flanges

AFJ 2" 150lbs RF, 316/316L, flange ANSI B16.5

AGJ 3" 150lbs RF, 316/316L, flange ANSI B16.5

AHJ 4" 150lbs RF, 316/316L, flange ANSI B16.5

EN flanges

CEJ DN40 PN10/16 B1, 316L, flange EN1092-1

CFJ DN50 PN10/16 B1, 316L, flange EN1092-1

CGJ DN80 PN10/16 B1, 316L, flange EN1092-1

CHJ DN100 PN10/16 B1, 316L, flange EN1092-1

JIS flanges

KEJ 10K 40 RF, 316L, flange JIS B2220

KFJ 10K 50 RF, 316L, flange JIS B2220

KGJ 10K 80 RF, 316L, flange JIS B2220

KHJ 10K 100 RF, 316L, flange JIS B2220

YYY Special version

170 Material of the process isolating diaphragm:

B AlloyC

L Rhodium>gold>AlloyC

N Platinum>gold>AlloyC

Y Special version

180 Fill fluid:

2 Inert oil

3 Synthetic oil, FDA

9 Special version

190 Seal:

A FKM Viton

J EPDM

L Kalrez 6375

U None, welded cell

Page 52: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

52 Endress+Hauser

FMB52 (continued) Additional ordering information (optional)

You can enter the versions for the specific feature in the following table. The versions entered make up the

complete order code.

500 Operating language:

AA English

AB German

AC French

AD Spanish

AE Italian

AF Dutch

AK Chinese

AL Japanese

550 Calibration:

F1 Factory calibration certificate, 5-point

570 Service:

HA Oil and grease removed 1)

1) Only device, not accessory or enclosed accessory

HC Cleaned for silicone-free applications )

IA Configured min alarm current

IB Configured HART Burst Mode PV

I9 Special version

580 Test, certificate:

JA EN10204-3.1 wetted material, inspection certificate

JB NACE MR0175 wetted

KD EN10204-3.1 helium leak test, inspection certificate

KE EN10204-3.1 pressure test, inspection certificate

KG EN10204-3.1 PMI test (PMI = positive material identification), inspection certificate

K9 Special version

600 Separate housing:

MA Cable PE, 2m/80inch + housing mounting bracket, wall/pipe, 304

MB Cable PE, 5m/200inch + housing mounting bracket, wall/pipe, 304

MC Cable PE, 10m/400inch + housing mounting bracket, wall/pipe, 304

MH Cable FEP, 5m/200inch IP69K + housing mounting bracket, wall/pipe, 304

610 Accessory mounted:

NA Overvoltage protection

620 Accessory enclosed:

QJ Welding neck G1-1/2, 316L

QK Welding neck G1-1/2, 316L, 3.1, EN10204-3.1 material, inspection certificate

QL Weld-in tool adapter G1-1/2, brass

RL Plug-in jack M12

RM Plug-in jack M12, 90deg

RN Plug-in jack M12, 90deg+5m cable

850 Firmware version:

78 01.00.zz, HART, DevRev01

895 Identification:

Z1 Measuring point (TAG)

Z2 Bus address

10 20 30 40 50 70 80 90 100 110 170 180 190 500 550 570 580 600 610 620 850 895

FMB52 -

Page 53: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 53

FMB53 This overview does not mark options which are mutually exclusive.

10 Approval:

AA For non-hazardous areas

BE ATEX II 2G Ex ia IIC T6

BG ATEX II 3G Ex ic IIC T6

IC IEC Ex ia IIC T6 Gb

IE IEC Ex ic IIC T6 Gc

CA CSA C/US IS Cl. I, II, III Div.1 Gr. A-G,

CSA C/US IS Cl. I Div. 2 Gr. A-D, Ex ia

CD CSA General Purpose

FE FM IS Cl.I Div.1 Gr.A-D, AEx ia, Zone 0,1,2

99 Special version

20 Output:

2 4-20mA HART

9 Special version

30 Display, operation:

1 LCD, push buttons

2 W/o LCD, push buttons

9 Special version

40 Housing:

I F31 aluminum

J F31 aluminum, glass window

Q F15 stainless steel Hygiene

R F15 stainless steel Hygiene, glass window

S F15 stainless steel Hygiene, plastic window

Y Special version

50 Electrical connection:

A Gland M20, IP66/68 NEMA4X/6P

C Thread G1/2, IP66/68 NEMA4X/6P

D Thread NPT1/2, IP66/68 NEMA4X/6P

I Connector M12, IP66/68, NEMA4X/6P

M Connector 7/8", IP66/68, NEMA4X/6P

P Connector Han7D, 90deg, IP65

V Valve connector ISO4400 M16, IP64

Y Special version

70 Sensor range:

1C 100mbar/10kPa/1.5psi relative, 1mH2O/3ftH2O/40inH2O

Overload: 4bar/400kPa/60psi

1F 400mbar/40kPa/6psi relative, 4mH2O/13ftH2O/160inH2O

Overload: 8bar/800kPa/120psi

1H 1.2bar/120kPa/18psi relative, 12mH2O/40ftH2O/480inH2O

Overload: 25bar/2.5MPa/375psi

1M 4bar/400kPa/60psi relative, 40mH2O/133ftH2O/1600inH2O

Overload: 25bar/2.5MPa/375psi

1P 10bar/1MPa/150psi relative, 100mH2O/333ftH2O/4000inH2O

Overload: 40bar/4MPa/600psi

99 Special version

80 Reference accuracy:

D Platinum

G Standard

Y Special version

90 Calibration; Unit:

A Sensor range; %

B Sensor range; mbar/bar

C Sensor range; kPa/MPa

D Sensor range; mm/mH2O

E Sensor range; inH2O/ftH2O

F Sensor range; psi

J Customized pressure; see additional spec.

K Customized level; see additional spec.

Y Special version

Page 54: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

54 Endress+Hauser

FMB53 (continued) 100 Probe connection:

15 ..... m cable, can be shortened, PE 0,5...400 m

25 ..... ft cable, can be shortened, PE 0,5...400 m

35 ..... m cable, can be shortened, FEP 2...1312 inch

45 ..... ft cable, can be shortened, FEP 2...1312 inch

99 Special version

170 Material of the process isolating diaphragm:

B AlloyC

L Rhodium>gold>AlloyC

N Platinum>gold>AlloyC

Y Special version

180 Fill fluid:

2 Inert oil

3 Synthetic oil, FDA

9 Special version

190 Seal:

A FKM Viton

J EPDM

L Kalrez 6375

U None, welded cell

Y Special version

Page 55: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 55

FMB53 (continued) Additional ordering information (optional)

You can enter the versions for the specific feature in the following table. The versions entered make up the

complete order code.

500 Operating language:

AA English

AB German

AC French

AD Spanish

AE Italian

AF Dutch

AK Chinese

AL Japanese

550 Calibration:

F1 Factory calibration certificate, 5-point

570 Service:

HA Oil and grease removed 1)

1) Only device, not accessory or enclosed accessory

HC Cleaned for silicone-free applications )

IA Configured min alarm current

IB Configured HART Burst Mode PV

I9 Special version

580 Test, certificate:

JA EN10204-3.1 wetted material, inspection certificate

JB NACE MR0175 wetted

KD EN10204-3.1 helium leak test, inspection certificate

KE EN10204-3.1 pressure test, inspection certificate

KG EN10204-3.1 PMI test (PMI = positive material identification), inspection certificate

K9 Special version

610 Accessory mounted:

NA Overvoltage protection

620 Accessory enclosed:

PO Suspension clamp, 316L

PW Extension cable shortening kit

RL Plug-in jack M12

RM Plug-in jack M12, 90deg

RN Plug-in jack M12, 90deg+5m cable

850 Firmware version:

78 01.00.zz, HART, DevRev01

895 Identification:

Z1 Measuring point (TAG)

Z2 Bus address

10 20 30 40 50 70 80 90 100 170 180 190 500 550 570 580 610 620 850 895

FMB53 -

Page 56: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

56 Endress+Hauser

Documentation

Technical Information • EMC test procedures: TI241F

• Deltabar M: TI434P/00/EN

• Cerabar M: TI436P/00/EN

Operating Instructions 4 to 20 mA HART:

• Cerabar M, Deltabar M, Deltapilot M: BA382P/00/EN

Brief Operating Instructions 4 to 20 mA HART:

• Deltapilot M: KA1033P/00/EN

Field Xpert: BA060S/04/EN

Safety Instructions

Authorities Version in the

order code

Approval Category Type Electronics Documentation

ATEX

BA Ex ia IIC II 1/2 G FMB50, FMB51, FMB52 – 4 to 20 mA HART – XA474P

BB Ex t IIC II 1/2 D FMB50, FMB51 – 4 to 20 mA HART – XA475P

BD Ex nA II 3 G FMB50, FMB51, FMB52, FMB53 – 4 to 20 mA HART – XA477P

BE Ex ia IIC II 2 G FMB50, FMB51, FMB52, FMB53 – 4 to 20 mA HART – XA474P

BG Ex ic IIC II 3 G FMB50, FMB51, FMB52, FMB53 – 4 to 20 mA HART – XA494P

B1Ex ia IIC

Ex ia IIC

II 1/2 G

II 1/2 DFMB50, FMB51 – 4 to 20 mA HART – XA476P

Authorities Version in the

order code

Approval EPL Type Electronics Documentation

IECEx

IA Ex ia IIC Ga/Gb FMB50, FMB51, FMB52 – 4 to 20 mA HART – XA478P

IC Ex ia IIC Gb FMB52, FMB53 – 4 to 20 mA HART – XA478P

ID Ex t IIIC Da/Db FMB50, FMB51 – 4 to 20 mA HART – XA479P

IE Ex ic IIC Gc FMB50, FMB51, FMB52, FMB53 – 4 to 20 mA HART – XA493P

I1Ex ia IIC

Ex ia IIIC

Ga/Gb

Da/DbFMB50, FMB51 – 4 to 20 mA HART – XA480P

Page 57: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 57

Installation/Control Drawings

Authorities Version in the

order code

Approval Type Electronics Documentation

FMFA

FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia,

FM NI Cl.I Div.2 Gr.A-D,

FM IS: Zone 0,1,2,20,21,22/FM NI: Zone 2

FMB50 – 4...20 mA HART – ZD236P

FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia,

Zone 0,1,2,20,21,22

FMB51 – 4...20 mA HART–

FC FM DIP Cl.II,III Div.1 Gr.E-G,

Zone 21,22

FMB50, FMB51 – 4...20 mA HART–

CSA

CA

C/US IS Cl.I,II,III Div.1 Gr.A-G,

C/US IS Cl.I Div.2 Gr.A-D, Ex ia, Zone

0,1,2

FMB50, FMB53 – 4...20 mA HART – ZD239P

C/US IS Cl.I,II,III Div.1 Gr.A-G,

C/US IS Cl.I Div.2 Gr.A-D, Ex ia C: Zone

0,1,2/

US: Zone 0,1,2,20,21,22

FMB51, FMB52 – 4...20 mA HART –

CC

CSA C/US Cl.II, III Div.1 Gr.E-G FMB50 – 4...20 mA HART –

CSA C/US Cl.II, III Div.1 Gr.E-G

US: Zone 21,22

FMB51 – 4...20 mA HART–

Page 58: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

58 Endress+Hauser

Accessories

Suspension clamp (FMB53

only)

ä 18 ff

Extension cable shortening kit

(FMB53 only)

ä 43 ff, feature 620, "Accessory enclosed", version "PW". For details refer to SD553P/00/a2.

M12 connector ä 14 ff

Welding necks and Weld-in

tool flanges

P01-PMx5xxxx-06-xx-xx-xx-008 P01-PMx5xxxx-06-xx-xx-xx-009 P01-PMx5xxxx-06-xx-xx-xx-010 P01-PMx5xxxx-11-xx-xx-xx-011 P01-PMx5xxxx-06-xx-xx-xx-005

Typ Uni D65 Uni D85 DRD DN50 Uni extens. 6" D85 G1-1/2, flush mounted

Material 316L

Order ä 43 ff, feature 620, "Accessory enclosed", versions see folowing table rows

FMB50 QT / QU Q2 / Q3 QP / QR Q5 / Q6 QJ / QK

FMB51 --- --- --- --- QJ / QK

FMB52 --- --- --- --- QJ / QK

Weld-in tool adapters

Material brass

FMB50 Q1 Q1 QS Q7 QL

FMB51 --- --- --- --- QL

FMB52 --- --- --- --- QL

44

39.5

Rd

52

x 1

/6

65

Ø

Ø

44

39.5

Rd

52

x 1

/6

85

ØØ

M10

12

17

20

5066

10

5

12

5

15

30°

Ø ØØ

Ø

44

14

1

Rd 52x1/6

15

3

21

.5 Ø

Ø

Ø

Ø

47.5

5285

25

Ø6

5

G1

1/2

A

Page 59: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 59

UNI process adapter

P01-PMx5xxxx-11-xx-xx-xx-006 P01-PMx5xxxx-11-xx-xx-xx-006 P01-PMx5xxxx-11-xx-xx-xx-006

Typ DIN11851 DN40 DIN11851 DN50 DRD DN50

Material 316L

Order ä 43 ff, feature 620, "Accessory enclosed", versions see folowing table

row

FMB50 RA / R1 RB / R2 RC / R3

P01-PMx5xxxx-11-xx-xx-xx-006 P01-PMx5xxxx-11-xx-xx-xx-006

Typ Clamp 2" Varivent

Material 316L

Order ä 43 ff, feature 620, "Accessory enclosed",

versions see folowing table row

FMB50 RD / R4 RF / R6

Ø4

4

Ø5

6

RD

52

x1/6

Ø5

1.6

Ø5

0

21

2639.5

10

Ø4

4R

D52x1

/6

Ø5

1.6

Ø6

68

28.5

39.5

Ø4

4R

D5

2x1/6

Ø5

1.6

Ø6

5

39.531.5

Ø44

RD

52x1

/6

Ø51.6

Ø64

39.5

39.5

RD

52x1

/6

44

68

84

ØØ Ø

Page 60: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

60 Endress+Hauser

Configuration data sheet (HART)

Level The following configuration data sheet has to be filled in and included with the order if the version

"K - Customized level" has been selected in feature 90 "Calibration; unit" in the product structure.

P01-FMB5Xxxx-16-xx-xx-en-000

� mbar � mmH2O � % � m � l � gal� bar � mH2O � dm � hl � Igal

� ftH2O � cm� psi � inH2O � mm � m3 � ft3

� in3 � kg� mmHg � Pa � inch � t

� ft � lb� kPa

� kgf/cm2 � MPa

(b)

(a)0 mbar

300 mbar3 m

0 m

Pressure Engineering Unit Output Unit (Scaled unit)

Empty calibration (a)Empty pressure (a)Low pressure value (empty)

[pres. eng. unit]

Damping

Damping: ____ sec (Default 2 sec)

Display Information

1st Value Display 2nd Value DisplayMeasured Value (PV) none (factory setting)

PressureCurrent [mA]

Measured value (%)

Temperature

High level value (full)

[Scaled Unit]

Full calibration (b)Full pressure (b)High pressure value (full)

[pres. eng. unit]

Low level value (empty)

[Scaled Unit]

Example

Page 61: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 61

Pressure The following configuration data sheet has to be filled in and included with the order if the version

"J - Customized pressure" has been selected in feature 90 "Calibration; unit" in the product structure.

P01-xxxxxxxx-16-xx-xx-xx-001

Note!

Smallest span (factory calibration) ä 9.

mbar mmH2O mmHg Pabar mH2O

ftH2O kPapsi inH2O kgf/cm

2MPa�

� �

� � � �

� �

Pressure Engineerung Unit

Calibration Range / Output

Display Information

Main Value none (default)

Current [mA]

Measured value (%)Temperature

Damping

Damping: ____ sec (Default 2 sec)

Low range value (LRV):_____________________ [pressure engineering unit)Upper range value (URV):_____________________ [pressure engineering unit)

1st Value Display 2nd Value display

Pressure

Page 62: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

62 Endress+Hauser

Page 63: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Endress+Hauser 63

Page 64: Deltapilot M FMB50/51/52/53 (Technische Information)

Deltapilot M FMB50/51/52/53

Instruments International

Endress+HauserInstruments International AGKaegenstrasse 24153 ReinachSwitzerland

Tel. +41 61 715 81 00Fax +41 61 715 25 [email protected]

TI437P/00/EN/12.09

No. 71107333