Princeton Power Systems Clean power made simple. Demand Response Inverter (DRI) Pre-configured Power Solution The multi-terminal DRI is a 10kW inverter uniquely flexible to be more reliable, more efficient, and more cost-effective than currently available inverters. The DRI’s distinctive E-Quad design combined with its split-phase electrical connections make it ideal for residential applications including residential off-grid systems, electric vehicle charging, and small- commercial applications. Efficient | Maximize energy. Maximize energy and minimize cost. Improves energy conversion efficiency. Programmable power curves and charge profiles also provide enhanced control for generators, AC loads, and batteries. Applications | Energy Storage Pre-installed energy management applications. Optimize local energy usage and costs with pre-programmed applications including peak- shaving, backup power, time-shifting, and frequency regulation. Flexible | Integrate quickly and easily. Highly programmable and easily integrated. E-Quad Technology allows power routing to the grid, DC energy storage, and dynamic AC loads. Multiple AC and DC terminals are ideal for microgrid and off-grid systems. Demand Response Inverter DRI-10 Grid-tied, Controllable 4-Terminal Power Conditioner DC DC AC Grid AC Load E-QUAD™ Power Flow Control Technology Dynamic control of four bi-directional loads/sources through a central high-frequency link Features & Options • Ground fault detection and interruption (GFDI optional) • Web-based performance monitoring. • Revenue-grade kWh meter (optional) • Manual AC and DC disconnects and combiner box (optional) • Utility interface communication modules for Modbus over RS485 and Ethernet (optional). • Level I/II EV Charging www.princetonpower.com Princeton Power DRI Princeton Power Systems Clean power made simple. Demand Response Inverter DRI-10 Grid-tied, Controllable 4-Terminal Power Conditioner Princeton Power Systems, Inc. 3175 Princeton Pike, Lawrenceville, NJ 08648 USA www.princetonpower.com Tel: (609) 955-5390 Fax: (609) 751-9225 [email protected] Press Inquiries: [email protected] Sales: [email protected] About Princeton Power Princeton Power Systems designs and manufactures high-performance power electronic converters and systems for commercial, industrial, and military distributed generation applications. General Specifications Power Rating 10 kW Inverter Technology 4-port PWM with central DC link Size and Weight 19.7 Wx15.8 Dx74.8 H; 440lbs Power Terminals Four (4): 2x DC, 2x AC DC Power Terminal Specifications (x2) Voltage Range 250-600 VDC 254-600VDC Max Power on and off-grid 36-254 VDC Power-Limited On-grid operation (power curve available) PV MPPT Range 260 — 590 VDC Power 10kW PV Array Configuration Positive Grounded/Negative Grounded Max. Current 40 A Control Functions Battery charge/discharge/bulk/float for lead-acid, lithium- ion, and lead-carbon and PV array control AC Grid Power Terminal Specifications Voltage 120/240 VAC +10%/-12% (Split Phase) Maximum Current 46 ARMS Power Factor 0.80 (lag) – 1 – 0.80 (lead) at rated power Line Frequency 60Hz (57.0 – 63.0Hz) Harmonics <5% THD IEEE 1547 Compliant AC Load Power Terminal Specifications Voltage Range 120/240 VAC +10%/-12% (Split Phase) Maximum Current 46 ARMS Overload Capability 150% for 10 seconds, 10-minute duty cycle Frequency Range 60Hz (59.3 – 60.0Hz) compliant with UL 1741 Control Functions Parallel operation and generator coordination for intelligent load shedding and generator start. Environmental Specifications Temperature Operating: 0 to 40°C Storage: -20 to 60°C Humidity 5 – 95% (non-condensing) Cooling Natural Convection/Fanless Rated Max Elevation 3,000 feet (full power) 5,000 feet (de-rated power) Enclosure NEMA 3 Safety Features Faults Over/Under Voltage/Frequency/Current/Temperature Standards Compliance IEEE 1547, CEC, UL 1741* Safety Features Anti-islanding, fused ground fault detection and interrupter, UL-compliant trip points (factory adjustable), Password protected parameters and Battery over/under-charge protection User Interface Features Front-Panel Interface Touch screen viewable in and protected from sunlight Communications MODBUS over RS485 or RS232 Performance Monitoring Local performance data storage, downloadable Web-based historical performance data hosting options Analog & Digital I/Os (2) inputs 0-24V, (3) output relays Efficiency Peak Efficiency 98.0% (PV or Battery to Grid) CEC Efficiency 96.5% (PV or Battery to Grid) Energy-Saving Features Smart load-shedding and Smart Relays Specifications subject to change without notice, contact manufacturer for updated information. Copyright © 2013 Princeton Power Systems, Inc. All rights reserved. Printed in the USA For more options please see our website

Upload: others

Post on 21-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Demand Response Inverter (DRI)...Performance Monitoring Local performance data storage, downloadable Web-based historical performance data hosting options Analog & Digital I/Os (2)

Princeton Power Systems Clean power made simple.™

Dem

and

Resp

onse

Inve

rter (

DRI

)

Pre-configured Power Solution The multi-terminal DRI is a 10kW inverter uniquely flexible to be more reliable, more efficient, and more cost-effective than currently available inverters. The DRI’s distinctive E-Quad design combined with its split-phase electrical connections make it ideal for residential applications including residential off-grid systems, electric vehicle charging, and small-commercial applications.

Efficient | Maximize energy.Maximize energy and minimize cost.Improves energy conversion efficiency. Programmable power curves and charge profiles also provide enhanced control for generators, AC loads, and batteries.

Applications | Energy StoragePre-installed energy management applications.Optimize local energy usage and costs with pre-programmed applications including peak-shaving, backup power, time-shifting, and frequency regulation.

Flexible | Integrate quickly and easily.Highly programmable and easily integrated.E-Quad Technology allows power routing to the grid, DC energy storage, and dynamic AC loads. Multiple AC and DC terminals are ideal for microgrid and off-grid systems.

Demand Response Inverter DRI-10Grid-tied, Controllable 4-Terminal Power Conditioner

DC

DC

AC Grid

AC Load

E-QUAD™ Power Flow Control Technology Dynamic control of four bi-directional loads/sources

through a central high-frequency linkF e a t u r e s & O p t i o n s• Ground fault detection and interruption (GFDI optional)

• Web-based performance monitoring.

• Revenue-grade kWh meter (optional)

• Manual AC and DC disconnects and combiner box (optional)

• Utility interface communication modules for Modbus over RS485 and Ethernet (optional).

• Level I/II EV Charging

www.princetonpower.com

Princeton Power DRI

Princeton Power Systems Clean power made simple.™

Demand Response Inverter DRI-10

Grid-tied, Controllable 4-Terminal Power Conditioner

Princeton Power Systems, Inc.

3175 Princeton Pike, Lawrenceville, NJ 08648 USA www.princetonpower.com Tel: (609) 955-5390 • Fax: (609) 751-9225 [email protected] • Press Inquiries: [email protected] • Sales: [email protected]

About Princeton PowerPrinceton Power Systems designs and

manufactures high-performance power electronic converters and systems for

commercial, industrial, and military distributed generation applications.

General SpecificationsPower Rating 10 kWInverter Technology 4-port PWM with central DC linkSize and Weight 19.7 Wx15.8 Dx74.8 H; 440lbsPower Terminals Four (4): 2x DC, 2x AC DC Power Terminal Specifications (x2)Voltage Range 250-600 VDC 254-600VDC Max Power on and off-grid 36-254 VDC Power-Limited On-grid operation (power curve available)PV MPPT Range 260 — 590 VDC Power 10kW PV Array Configuration Positive Grounded/Negative GroundedMax. Current 40 AControl Functions Battery charge/discharge/bulk/float for lead-acid, lithium- ion, and lead-carbon and PV array control

AC Grid Power Terminal SpecificationsVoltage 120/240 VAC +10%/-12% (Split Phase)Maximum Current 46 ARMSPower Factor 0.80 (lag) – 1 – 0.80 (lead) at rated powerLine Frequency 60Hz (57.0 – 63.0Hz)Harmonics <5% THD IEEE 1547 CompliantAC Load Power Terminal SpecificationsVoltage Range 120/240 VAC +10%/-12% (Split Phase)Maximum Current 46 ARMSOverload Capability 150% for 10 seconds, 10-minute duty cycleFrequency Range 60Hz (59.3 – 60.0Hz) compliant with UL 1741Control Functions Parallel operation and generator coordination for intelligent load shedding and generator start.Environmental SpecificationsTemperature Operating: 0 to 40°C Storage: -20 to 60°CHumidity 5 – 95% (non-condensing)Cooling Natural Convection/FanlessRated Max Elevation 3,000 feet (full power) 5,000 feet (de-rated power) Enclosure NEMA 3 Safety FeaturesFaults Over/Under Voltage/Frequency/Current/Temperature Standards Compliance IEEE 1547, CEC, UL 1741*Safety Features Anti-islanding, fused ground fault detection and interrupter,

UL-compliant trip points (factory adjustable), Password protected parameters and Battery over/under-charge protection

User Interface FeaturesFront-Panel Interface Touch screen viewable in and protected from sunlightCommunications MODBUS over RS485 or RS232Performance Monitoring Local performance data storage, downloadable Web-based historical performance data hosting optionsAnalog & Digital I/Os (2) inputs 0-24V, (3) output relays EfficiencyPeak Efficiency 98.0% (PV or Battery to Grid)CEC Efficiency 96.5% (PV or Battery to Grid)Energy-Saving Features Smart load-shedding and Smart Relays

Specifications subject to change without notice, contact manufacturer for updated information.

Copyright © 2013 Princeton Power Systems, Inc. All rights reserved. Printed in the USA

Fo r m o r e o p t i o n s p l e a s e s e e o u r w e b s i t e

Page 2: Demand Response Inverter (DRI)...Performance Monitoring Local performance data storage, downloadable Web-based historical performance data hosting options Analog & Digital I/Os (2)

Appl

icatio

ns N

ote

(DRI

) Princeton Power Systems Clean power made simple.™

DC

DC AC Backup Loads

AC Grid

AC Grid

Grid-Support Functions • Area Frequency Regulation• Arbitrage• Automatic peak shaving • VAR Support

Princeton Power Systems, Inc. Tel: (609) 955 5390 Fax: (609) 751 9225 [email protected][email protected][email protected] • www.princetonpower.com

Available Configurations DRI systems are available in several

pre-configured designs or customer specific systems can be designed.

1. 10 kW System • Residential • EV Charging (Level II) 2. 30 kW System • EV Fast Charging (Level III) • Small Commercial

DC Car

DC

DC

AC Grid

Generator

Residential and Commercial Backup • Critical load backup powered by solary/battery• Grid support services• Peak shaving• Time shifting

EV Charging • Enables fast charging 1741• CHAdeMO, SAE Level 1, 2, or 3 • Provides grid support services• Optional PV input for solar charging

Microgrid or Off-grid• AC-coupled for high efficiency• Wide compatibility with

AC generators (diesel, gas, etc.)• Optional PV or Wind inputs• Seamless electric grid interface

DC (Optional)

Common Configurations Key Features

Pre-configured systems are available or specific batteries can be integrated. • Lead-Acid (PbA) • Lithium-ion Phosphate (Li Ph) • Lead-Carbon (PbC) • Sodium Metal Halide (NaMX)

Battery Types DRI systems work with multiple battery types from a variety of manufacturers, including the leading providers of lithium-ion and lead-acid technologies.

120

110

100

90

80

60

40

201 3 5 7 9 11 13 15 17 19 21 23

HOURS

Load

in M

W x

100

00’s

REGULATION

1

0.5

0

-0.5

-1

REG

ULA

TIO

N

TIME(mSec)

BATTERY RESPONSE

0 50 100 150 200 250 300 350 400 450 500

EV Charging

Residential

Small Commercial

Lead-Acid (PbA)

Lithium-ion (Li )

Lead-Carbon (PbC)

AC loads