density and concentration measurement

Upload: mesharialenezi

Post on 30-May-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/9/2019 Density and Concentration Measurement

    1/33

    1

    Density and Concentration Measurement

    DT Series Magd Nasr Ph.Dr.Eng.

  • 8/9/2019 Density and Concentration Measurement

    2/33

    Basic Concepts

    Introduction to the DT series Transmitter

    Oil & Gas Applications

    DT Series

  • 8/9/2019 Density and Concentration Measurement

    3/33

  • 8/9/2019 Density and Concentration Measurement

    4/33

    Interface Level = 0 to 100%

    100 %

    0 %

    Oil

    Water

    Interface Level Measurement MethodInterface Level Measurement Method

    The interface level isproportional to the output

    signal.

  • 8/9/2019 Density and Concentration Measurement

    5/33

    Introduction

    DT Series

  • 8/9/2019 Density and Concentration Measurement

    6/33

    PRESSURE

    SENSORSPRESSURE

    SENSORS

    TEMPERATURE

    SENSOR

    PROCESSCONECTION

    FLANGE

    ANSI B16.5

    PROCESS

    CONECTION

    FLANGE

    ANSI B16.5

    CAPACITIVE CELL

    ELECTRONICS

    &

    LOCAL LCD

    DT SeriesDT Series -- ConfigurationConfiguration

    Side

    Mounting

    Top

    Mounting

  • 8/9/2019 Density and Concentration Measurement

    7/33

    Density:

    SI system unit: kg/m3

    Commonly used units: g/cm3 or g/l

    English system unit: lbm/ft3

    A.P.I. Concentration:

    Degrees: Baum, Gay-Lussac, INPM

    % of Solids

    Measurement UnitsMeasurement Units

  • 8/9/2019 Density and Concentration Measurement

    8/33

    Designed for Density, Concentration & Interface level ON LINE

    measurements Two-wire loop powered equipment, 12 to 45 Vdc

    Communication:

    4-20mA + Hart (DT301),

    Foundation Fieldbus (DT302)

    Profibus (DT303)

    Remote monitoring and calibration using Palm Handheld and /or PC

    Single integrated unit, no moving parts Local digital indicator

    Direct readout in several engineering units

    Process temperature indication,

    Temperature variable output available only in bus version

    Suitable for dynamic and static liquids

    Explosion-proof and intrinsically safe

    CharacteristicsCharacteristics

  • 8/9/2019 Density and Concentration Measurement

    9/33

    Working Ranges

    Ranges

    Range 1 : 0.5 to 1.8 g/cm3

    Range 2 : 1.0 to 2.5 g/cm3

    Range 3 : 2.0 to 5.0 g/cm3

    Minimum Span

    Range 1 : 0.025 g/cm3

    Range 2 : 0.050 g/cm3

    Range 3 : 0.250 g/cm3

    Accuracy

    Range 1: 0.0004 g/cc

    Range 2: 0.0007 g/cc Range 3: 0.0016 g/cc

  • 8/9/2019 Density and Concentration Measurement

    10/33

    Temperature Limits

    Ambient: -40 to 85 C

    Process: -20 to 150 C

    Static Pressure Limit:

    70 Bar (1,015 psi)

    Viscosity:

    No known limits, already used in

    liquids with 10,000 Cp

    Working ConditionsWorking Conditions

  • 8/9/2019 Density and Concentration Measurement

    11/33

    Materials

    Probe

    Stainless Steel 316L SST

    Hastelloy C276

    Diaphragm

    Stainless Steel 316L SST

    Hastelloy C276

    Housing Aluminum Alloy

    Stainless Steel 316L SST

    Measurement Tank Stainless Steel 316L SST

  • 8/9/2019 Density and Concentration Measurement

    12/33

    Process Connection

    Process Connection

    Flange size: 4 RF

    Pressure rating: Ansi 150, 300, 600

  • 8/9/2019 Density and Concentration Measurement

    13/33

    DT Series Features

    Easy Installation

    Low Maintenance

    High Accuracy

    No special training

    Easy setup and calibration

  • 8/9/2019 Density and Concentration Measurement

    14/33

    Typical Installation

    DT Series

  • 8/9/2019 Density and Concentration Measurement

    15/33

    Online Installation, PipelinesOnline Installation, Pipelines

  • 8/9/2019 Density and Concentration Measurement

    16/33

    Tank InstallationTank Installation

  • 8/9/2019 Density and Concentration Measurement

    17/33

    Separator tank InstallationSeparator tank Installation

  • 8/9/2019 Density and Concentration Measurement

    18/33

    Applications

    Exploration

    Oil & Gas Production

    DT Series

  • 8/9/2019 Density and Concentration Measurement

    19/33

    Exploration Application

    Drilling Mud Density

    Brine Density Ballast Density

    Fluid Interface

  • 8/9/2019 Density and Concentration Measurement

    20/33

    Oil & Gas Production Applications

    Online Measurement

    Tank Level Interface Measurement Online Blending

  • 8/9/2019 Density and Concentration Measurement

    21/33

    Application:

    Crude oil densitymeasurement, direct in line at

    90 m3/h

    Online Density MeasurementOnline Density Measurement

  • 8/9/2019 Density and Concentration Measurement

    22/33

    Application:

    Vertical Separator tank

    Interface Level MeasurementInterface Level Measurement

  • 8/9/2019 Density and Concentration Measurement

    23/33

    Customer: Petrobras

    Location: So Miguel dosCampos, Alagoas State,

    Brazil.

    Application:

    Interface Level Oil / Salt

    Water

    Interface Level MeasurementInterface Level Measurement

  • 8/9/2019 Density and Concentration Measurement

    24/33

    Reference Letter:

    Interface Level of Oil/ Salt Water

    PetrobrsPetrobrs Reference LetterReference Letter

  • 8/9/2019 Density and Concentration Measurement

    25/33

    Customer: PetrobrasLocation: Merluza Platform,

    Santos Basin, Brazil

    Application:

    Density of condensed gas

    DT SeriesDT Series Offshore ApplicationOffshore Application

  • 8/9/2019 Density and Concentration Measurement

    26/33

    Customer: PetrobrasLocation: Marlim Sul Field,

    Campos Basin, Brazil

    Application:

    Interface Level Oil / Water

    DT SeriesDT Series Offshore ApplicationOffshore Application

  • 8/9/2019 Density and Concentration Measurement

    27/33

    Application:

    Horizontal Crude Oil Separator tank

    Interface Level MeasurementInterface Level Measurement

  • 8/9/2019 Density and Concentration Measurement

    28/33

    Application:

    Project Oil Separator tank and

    Water Cut

    Water Cut MeasurementWater Cut Measurement

  • 8/9/2019 Density and Concentration Measurement

    29/33

    Application:

    Oil-Emulsion-Water tank separator

    Online Separation MeasurementOnline Separation Measurement

  • 8/9/2019 Density and Concentration Measurement

    30/33

    Application:

    Liquid Custody Transfer Measurement Skids

    Custody TransferCustody Transfer

  • 8/9/2019 Density and Concentration Measurement

    31/33

    Application:

    Fieldbus Blending Solution

    Online BlendingOnline Blending

  • 8/9/2019 Density and Concentration Measurement

    32/33

    Application:

    Fieldbus Blending Solution

    Online Concentration MeasurementOnline Concentration Measurement

  • 8/9/2019 Density and Concentration Measurement

    33/33

    END