densitypro / densitypro + hart operation guide.pdf · the material in this manual is proprietary...

35
Part of Thermo Fisher Scientific DensityPRO / DensityPRO+ With HART ® Protocol Interface Operation Guide P/N 717816 Revision C

Upload: vananh

Post on 30-Aug-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Part of Thermo Fisher Scientific

DensityPRO / DensityPRO+ With HART® ProtocolInterface Operation GuideP/N 717816

Revision C

Page 2: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank
Page 3: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO / DensityPRO+ With HART® ProtocolInterface Operation GuideP/N 717816

Revision C

Page 4: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank
Page 5: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

© 2011 Thermo Fisher Scientific Inc. All rights reserved.

“Microsoft” and “Windows” are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. “HART” is a registered trademark of the HART Communication Foundation. “Motorola” is a registered trademark of Motorola, Inc.

All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.

Thermo Fisher Scientific Inc. (Thermo Fisher) makes every effort to ensure the accuracy and completeness of this manual. However, we cannot be responsible for errors, omissions, or any loss of data as the result of errors or omissions. Thermo Fisher reserves the right to make changes to the manual or improvements to the product at any time without notice.

The material in this manual is proprietary and cannot be reproduced in any form without expressed written consent from Thermo Fisher.

Page 6: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

This page intentionally left blank.

Page 7: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide v

Revision History

Revision Level Date Comments

1.0 05-2001 Initial release

A 03-2006 Company name and address change. Reformatted. Added HART 375 Communicator.

B 09-2007 Per ECO 5987.

C 02-2011 Per ECO 7649.

Page 8: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

This page intentionally left blank.

Page 9: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide vii

Contents Chapter 1 Overview............................................................................................................. 1-1

Introduction........................................................................................ 1-1 Terms.................................................................................................. 1-1 Theory of Operation ........................................................................... 1-2

HART Board ................................................................................... 1-2 DensityPRO DD ............................................................................. 1-2 Gauge .............................................................................................. 1-2

Contact Information ........................................................................... 1-3

Instrument Setup with HART .......................................................................... 2-1 Chapter 2

Chapter 3 HART Multi-Drop Mode ................................................................................... 3-1 HART Unique ID .............................................................................. 3-1 HART Polling Address ....................................................................... 3-1 Exiting Multi-Drop............................................................................. 3-1 Limitations in Multi-Drop Mode........................................................ 3-2

Certifications ..................................................................................................... 4-1 Chapter 4

Appendix A DensityPRO DD Flowcharts ........................................................................... A-1

Page 10: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

This page intentionally left blank.

Page 11: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Chapter 1

Overview

This manual describes the setup and operation of the optional HART interface for the Thermo Scientific DensityPRO or DensityPRO+ gamma density systems. This interface includes:

Introduction troduction

● HART interface, which consists of a Motorola 68HC12 P and interface circuitry to both the instrument and the HART bus. This board is a piggyback that mounts on the DC power I/O relay PWA 886675.

● DensityPRO+ HART Device Description (DD), which offers access to the instrument’s measurement data and basic setup functions. This DD is typically loaded into the 275 / 375 (or later) Field Communicator from Emerson Electric Co.

Note It is assumed that readers have a basic familiarity with the gauge. If necessary, refer to the Density PRO user guide (p/n 717784) or DensityPRO+ user guide (p/n 717819). ▲

Terms Terms The following terms are used in this document:

● HART: An acronym for Highway Addressable Remote Transducer. The protocol is maintained by the HART Communication Foundation.

● Device Description (DD): A program script that contains the menus/methods for interacting with a HART instrument. The Fisher Rosemount 275/375/later has a built-in interpreter to run DD scripts. The DensityPRO+ DD is referred to as DensityPRO DD.

● HART board: The HART interface for DensityPRO / DensityPRO +.

● 275/375/later: The 275/375/later Field Communicator from Emerson Electric Co.

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide 1-1

Page 12: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Overview Theory of Operation

Theory of Operation

HART Board The HART board serves as an intelligent pass-through between the “external” HART world and the gauge. It has three responsibilities:

● Maintain a local copy of all gauge setup data for fast retrieval.

● Offer real-time access to the gauge’s process and alarm data.

● Translate incoming HART requests to the equivalent native gauge requests, collect the data, and send the response to the HART requestor.

On the gauge side, the HART board co-opts the gauge’s RS232 port and talks to it in logic levels in the usual ASYNC format. On the HART side, the HART telemetry is “mixed” with the gauge’s 4–20 mA current out. The HART master (usually the 275/375/later field communicator) talks to the gauge over its current loop.

DensityPRO DD The DensityPRO DD is designed to offer access to the gauge’s process data and basic setup functions, including:

● Primary measurement setup

● Process alarms

● Additional measurements

● Current output settings

● Gauge fine tuning

● Action items (gauge restart, erase memory)

As practical, the DD menu structure mirrors that found in the gauge. The DD menu flowcharts appear in Appendix A.

Gauge Once the HART board is installed, the gauge enters a special mode of operation by:

● Overriding all user RS232 selections and setting the port to 96007E1, Blind Mode, data streaming inhibited.

● Disabling all RS232 setup menus in the gauge user system.

● Enabling HART board software watchdog, which monitors HART board data requests. The watchdog will raise a system fault alarm if there were no requests received in a one-minute interval.

1-2 DensityPRO / DensityPRO+ HART Operation Guide Thermo Fisher Scientific

Page 13: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Overview Contact Information

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide 1-3

Contact Information

If you have questions or require additional technical support, you can contact Thermo Fisher directly.

Process Instruments

1410 Gillingham Lane Sugar Land, TX 77478 USA +1 (800) 437-7979 +1 (713) 272-0404 direct +1 (713) 4573 fax

14 Gormley Industrial Avenue Gormley, Ontario L0H 1G0 CANADA +1 (905) 888-8808 +1 (905) 888-8828 fax

Unit 702-715, 7/F Tower West Yonghe Plaza No. 28 Andingmen East Street, Beijing 100007 CHINA +86 (10) 8419-3588 +86 (10) 8419-3580 fax

A-101, 1CC Trade Tower Senapati Bapat Road Pune 411 016 Maharashtra, INDIA +91 (20) 6626 7000 +91 (20) 6626 7001 fax

Ion Path, Road Three Winsford, Cheshire CW7 3GA UNITED KINGDOM +44 (0) 1606 548700 +44 (0) 1606 548711 fax

www.thermoscientific.com

Page 14: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

This page intentionally left blank.

Page 15: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide 2-1

Chapter 2

Instrument Setup with HART

To facilitate ease of use, the DensityPRO DD was specifically modeled from the gauge’s built-in menu system. Refer to Appendix A for details.

Page 16: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

This page intentionally left blank.

Page 17: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Chapter 3

HART Multi-Drop Mode

The DensityPRO / DensityPRO+ HART supports the HART multi-drop mode where up to 15 slaves can be interconnected on a single current loop. While in this mode, the gauge parks its current out at 3.8 mA. Each slave must be assigned an individual unique ID and polling address to be accessed by a HART Master.

HART Unique ID The unique ID is a 24-bit number that the HART protocol uses to distinguish between slaves in the long-addressing format. The gauge stores this ID in non-volatile (NV) RAM. It is shipped with an ID of 0. At power-up, the HART board reads this ID from the gauge.

The ID may be set via the gauge’s built-in user interface, with the Thermo Scientific 9734 RS485 Handheld. To set a unique ID using direct entry:

1. Enable the protected NV section (0130101).

2. Assign a non-zero HART unique ID (019015 SN, where SN is a 24-bit hexadecimal number from 1 to 0xFFFFFF).

HART Polling Address

The polling address is an 8-bit number (0–15), which is used to distinguish between slaves in the short-addressing format. The polling address resides in the HART board’s NVRAM. The FR275/375/later is typically used to assign the polling address (refer to the FR275/375/later user guide). Once the polling address is assigned, the gauge parks its current out at 3.8 mA.

Exiting Multi-Drop

Exit multi-drop mode by restoring the gauge’s polling address to zero. Afterward, the current out operation will return to normal.

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide 3-1

Page 18: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

HART Multi-Drop Mode Limitations in Multi-Drop Mode

3-2 DensityPRO / DensityPRO+ HART Operation Guide Thermo Fisher Scientific

Limitations in Multi-Drop Mode

While in multi-drop mode, the gauge current output will not:

● Track the measurement (PV)

● Perform user current hold commands

● Perform current out alarm actions (go to Fault Low/Fault High)

Page 19: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Chapter 4

Certifications

The DensityPRO / DensityPRO+ HART conforms to the HART Physical Layer Specification Rev. 5.0.

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide 4-1

Page 20: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

This page intentionally left blank.

Page 21: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Appendix A

DensityPRO DD Flowcharts

The DensityPRO DD is designed to offer access to the gauge’s process data and basic setup functions. The DD menu flowcharts appear on the following pages.

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide A-1

Page 22: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

A-2 DensityPRO / DensityPRO+ HART Operation Guide Thermo Fisher Scientific

Page 23: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide A-3

Page 24: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

A-4 DensityPRO / DensityPRO+ HART Operation Guide Thermo Fisher Scientific

Page 25: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide A-5

Page 26: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

A-6 DensityPRO / DensityPRO+ HART Operation Guide Thermo Fisher Scientific

Page 27: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide A-7

Page 28: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

A-8 DensityPRO / DensityPRO+ HART Operation Guide Thermo Fisher Scientific

Page 29: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide A-9

Page 30: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

A-10 DensityPRO / DensityPRO+ HART Operation Guide Thermo Fisher Scientific

Page 31: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide A-11

Page 32: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

A-12 DensityPRO / DensityPRO+ HART Operation Guide Thermo Fisher Scientific

Page 33: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

DensityPRO DD Flowcharts

Thermo Fisher Scientific DensityPRO / DensityPRO+ HART Operation Guide A-13

Page 34: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

This page intentionally left blank.

Page 35: DensityPRO / DensityPRO + HART Operation Guide.pdf · The material in this manual is proprietary and cannot be reproduced in any form without ... This page intentionally left blank

Thermo Fisher Scientific81 Wyman StreetP.O. Box 9046Waltham, Massachusetts 02454-9046United States

www.thermofisher.com