dental implant system · 02 shinsaegi medi-tech view of company work flow concept of cad/cam system...
TRANSCRIPT
02 SHINSAEGI MEDI-TECH
View of company
Work Flow Concept of CAD/CAM System
Packing design Un-packing Protocol
ALIA Locking Abutment ALIPS Locking Abutment Screw
Mountless driver system Length of the implant(EST, SST, IST, IT)
Introduction of SG Implant
EST System
- External Slightly Tapered Fixture(EST)
- Prosthetic Flow diagrams and components for Cemented Abutment, Angled Abutment, UCLA Gold Abutment, UCLA Plastic Abutment, Temporary Abutment.
- Prosthetic Flow diagrams and components for Estheticone, Midicone, Widecone, Locking Abutment.
- Prosthetic Flow diagrams and components for O-Ring Abutment.
SST System
- Internal Submerged Slightly Tapered Fixture(SST)
- Prosthetic Flow diagrams and components for Sub-Solid Abutment.
- Prosthetic Flow diagrams and components for Sub-Cemented Abutment, Sub-Angled Abutment, Sub-Temporary Abutment, Sub-Gold Abutment.
- Prosthetic Flow diagrams and components for Sub-Locking Abutment.
- Prosthetic Flow diagrams and components for Sub-O-Ring Abutment.
IST System
- Internal Slightly Tapered Fixture(IST)
IT System
- Internal Tapered Fixture(IT)
- Prosthetic Flow diagrams and components for Solid Abutment, Excellent Solid Abutment.
- Prosthetic Flow diagrams and components for In-Octa Cemented Abutment, In-Octa Gold Abutment, Solid Angled Abutment, In-Octa Locking Abutment.
- Prosthetic Flow diagrams and components for Octa Abutment.
- Prosthetic Flow diagrams and components for O-Ring Abutment.
Surgical Instrument
- Surgical Instrument for EST, SST, IST, IT
- Drill system
- Surgical Drilling protocol and Dimensions
- Surgical protocol for EST, SST, IST, IT
- Surgical kit contents
03040506070811
29
43
47
65
CONTENTS
03SHINSAEGI MEDI-TECH
View of company
Company : SHINSAEGI Medi-Tech Co., Ltd.
Head office & Manufacture Address :
Busan-city, Gang Seu-Gu, Ji Sa-Dong 1212, Korea
TEL : 82-51-971-2811 FAX : 82-51-971-2814
E-mail : [email protected]
Business : Medical Instrument Manufacture & Marketing
Product :
Dental Implant (Manufacture&Marketing)
Dental CAD/CAM (Manufacture&Marketing)
Titanium & Stainless (Import & Marketing)
Dental Materials & Instrument (Manufacture & Marketing)
Homepage : http://sgimplant.com
04 SHINSAEGI MEDI-TECH
Work Flow Concept of CAD/CAM System
Preparation Model Preparation Scanning
Sintering Milling M/C Design
Veneering Cementation Scanning
05SHINSAEGI MEDI-TECH
This Ampule has been divided color for easyNarrow(Red) Regular(Yellow) Wide(Green) Wide 6.0(Blue)
Narrow Regular Wide Wide 6.0
Packing design
Implant Un-packing Protocol
1 2Peel back thetray lid to exposethe implant.
Removecontents fromthe implantbox.
3 4 5Pick-up theimplant from thesurgical ampuleusing the fixturemount driver.
Draw open acover of implant.
Mountlessdelivery systemfor easy andsafety.
06 SHINSAEGI MEDI-TECH
This innovate Locking Abutment released from Screw loosening. [ Patent No. US 7.393.210 B2 ]
ALIA Locking Abutment
ALIPS Locking Abutment Screw
ALIPS (Anti Lock Inner Post Screw) [ Patent No. US 6.857.874 B2 ]
External Hex Type(EST)
Submerged Internal Hex Type(SST)
Internal Octa Type(IST&IT)
External Hex Type(EST)
Submerged Internal Hex Type(SST)
Internal Octa Type(IST&IT)
07SHINSAEGI MEDI-TECH
EST SST IST IT
1.8 mm
Length(L) 7, 9, 11, 13, 15mm
0.75 mm
- Care must be taken when inserting the implant placement driver tip into the implant.- A very low RPM speed must be used as you approach the internal hex and octa connection and external hex
connection of the implant with the driver tip.
- Regardless of the implant type, the length of the implant is the same from the top of the implant collar(platform) to the tip of the implant.
Pick-up and delivery of implant
Mountless driver system
Length of the implant(EST, SST, IST, IT)
External Hex Type(EST)
Submerged Internal Hex Type(SST)
Internal Octa Type(IST&IT)
08 SHINSAEGI MEDI-TECH
Introduction of SG Implant
External Slightly Tapered Fixture (EST)
No Code
EFSN309EFSN311EFSN313EFSN315
EFSR407EFSR409EFSR411EFSR413EFSR415
EFSW507EFSW509EFSW511EFSW513EFSW515
3.53.53.53.5
4.14.14.14.14.1
5.15.15.15.15.1
5.05.05.05.05.0
3.43.43.43.43.4
3.43.43.43.43.4
4.04.04.04.04.0
3.43.43.43.4
9.011.013.015.0
7.09.0
11.013.015.0
7.09.0
11.013.015.0
2.72.72.72.72.7
2.62.62.62.62.6
2.42.42.42.4
2.22.22.22.2
1234
56789
1011121314
EFSW607EFSW609EFSW611EFSW613
5.15.15.15.1
5.95.95.95.9
3.43.43.43.4
4.54.54.54.5
7.09.0
11.013.0
15161718
Size (mm)
DiameterD0
DiameterD1
LengthL0
HexH
ApexA
No Code
SFSN309SFSN311SFSN313SFSN315
SFSR407SFSR409SFSR411SFSR413SFSR415
SFSW507SFSW509SFSW511SFSW513SFSW515
3.83.83.83.8
4.34.34.34.34.3
5.05.05.05.05.0
4.94.94.94.94.9
2.52.52.52.52.5
3.63.63.63.63.6
4.24.24.24.24.2
3.753.753.753.75
9.011.013.015.0
7.09.0
11.013.015.0
7.09.0
11.013.015.0
2.52.52.52.52.5
2.92.92.92.92.9
2.52.52.52.5
2.22.22.22.2
1234
56789
1011121314
SFSW607SFSW609SFSW611SFSW613
6.06.06.06.0
5.95.95.95.9
2.52.52.52.5
4.34.34.34.3
7.09.0
11.013.0
15161718
Size (mm)
DiameterD0
DiameterD1
LengthL0
HexH
ApexA
D0
D1
A
L0
H
D0
D1
A
L0
H
Submerged Slightly Tapered Fixture(SST)
09SHINSAEGI MEDI-TECH
Internal Slightly Tapered Fixture(IST)
No Code
IFSR407IFSR409IFSR411IFSR413IFSR415
IFSW507IFSW509IFSW511IFSW513IFSW515
4.84.84.84.84.8
4.84.84.84.84.8
4.84.84.84.84.8
3.13.13.13.13.1
2.62.62.62.62.6
4.14.14.14.14.1
7.09.0
11.013.015.0
7.09.0
11.013.015.0
3.13.13.13.13.1
2.42.42.42.42.4
12345
6789
10
IFSW607IFSW609IFSW611IFSW613
6.06.06.06.0
5.35.35.35.3
3.13.13.13.1
4.04.04.04.0
7.09.0
11.013.0
11121314
Size (mm)
DiameterD0
DiameterD1
LengthL0
OctaO
ApexA
No Code
IFTR407IFTR409IFTR411IFTR413IFTR415
IFTW507IFTW509IFTW511IFTW513IFTW515
4.84.84.84.84.8
4.84.84.84.84.8
4.84.84.84.84.8
3.13.13.13.13.1
3.13.13.13.13.1
4.14.14.14.14.1
7.09.0
11.013.015.0
7.09.0
11.013.015.0
3.13.13.13.13.1
2.42.42.42.42.4
12345
6789
10
IFTW607IFTW609IFTW611IFTW613
6.06.06.06.0
5.35.35.35.3
3.13.13.13.1
3.63.63.63.6
7.09.0
11.013.0
11121314
Size (mm)
DiameterD0
DiameterD1
LengthL0
OctaO
ApexA
Internal Tapered Fixture(IT)
D0
D1
A
L0
1.8
O
D0
D1
A
L0
1.8
O
Introduction of SG Implant
EST System
12 SHINSAEGI MEDI-TECH
Cover ScrewHeadless Cover ScrewHealing AbutmentCemented AbutmentCemented Abutment T-TypeCemented Abutment ScrewCemented Abutment Screw (T-Type)ALIPS Locking Abutment ScrewFixture Lab Analog(UCLA)Angled AbutmentAngled Abutment ScrewUCLA Gold AbutmentUCLA Plastic AbutmentUCLA Temporary AbutmentImpression Coping(Pick-up)Guide Pin(Pick-up)Impression Coping(Transfer)Guide Pin(Transfer)Conical AbutmentConical Abutment ScrewConical Healing CapConical Gold CylinderConical Plastic CylinderConical Temporary CylinderConical Cylinder ScrewConical Impression Coping(pick-up)Conical Guide Pin(pick-up)Conical Impression Coping (Transfer)Conical Lab AnalogALIA External Locking Abutment (Hex)External Locking Abutment ScrewExternal YK Transfer AdapterExternal YK Transfer ScrewImpression Plastic CapExternal Locking Lab AnalogO-Ring AbutmentO-RingO-Ring RetainerO-Ring Lab Analog
16p16p16p17p17p17p18p18p18p18p19p19p19p19p20p20p20p20p22p22p22p22p23p23p23p23p24p24p24p24p25p25p25p25p25p27p27p27p27p
01
02
03
04050607
08
09
10
13SHINSAEGI MEDI-TECH
External Slightly Tapered Fixture(EST System)EST Implant components and Branemark, 3i, implant components are fully interchangeable.
SU
BM
ER
GE
D (S
ST
)IN
TE
RN
AL
(IST
.IT)
INT
ER
NA
L (IS
T.IT
)
The inner of head
External Hex connectionHex height-0.75mm
Micro groove
- Acheive both soft and hard tissue attachement
- Generate strong attachment of cortical bone
- Superior primary stability
Apex
Sharp tip on 3-cutting edge-This sharp tip also secures a smooth insertion without the implant wobbling
-Implant will not spin and loss stablity when a higher density area in reached
-This thread design make the implant a very efficient selftapping unit.
Body of head
Flapless surgery- Head design is the same diameter as the implant body
- This implant ideal for surgeryNo counter sinking- This makes the surgical
procedure faster and simple.
Body design
Slightly taper-This design for increased initial stablity in soft bone
Unique grooves-Increase stability compared to "v"type thread implant
EX
TE
RN
AL
(E
ST
)
14 SHINSAEGI MEDI-TECH
External Slightly Tapered Fixture (EST System)
- Submerged External hex connection (Hex height 2.7mm)- Apex size : Narrow( 2.2mm), Regular( 2.6mm), Wide( 3.4mm), Wide6.0( 4.5mm)- Torque recommendation : 40Ncm
Unit : mm
Feature
Narrow EST SystemPlatform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Hex(H)
Length(L)
Code
EFSN309
EFSN311
EFSN313
EFSN315
9
11
13
15
2.43.43.53.5
Unit : mmWide6.0 EST SystemPlatform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Hex(H)
Length(L)
Code
EFSW607
EFSW609
EFSW611
EFSW613
7
9
11
13
3.45.96.05.1
Unit : mmRegular EST SystemPlatform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Hex(H)
Length(L)
Code
EFSR407
EFSR409
EFSR411
EFSR413
EFSR415
7
9
11
13
15
2.74.04.14.1
Unit : mmWide EST SystemPlatform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Hex(H)
Length(L)
Code
EFSW507
EFSW509
EFSW511
EFSW513
EFSW515
7
9
11
13
15
3.45.05.15.1
L
D2
D1||
D0
Hex
L
D2
D1||
D0
Hex
L
D2
D1||
D0
Hex
L
D2
D0
D1
Hex
15SHINSAEGI MEDI-TECH
Cement Retained Restoration : Cemented Abutment, Angled Abutment, UCLA Gold Abutment, UCLA Plastic Abutment,Temporary Abutment
Fixture(EST)
(Hex) (Non Hex)Fixture Impression Coping (Pick-up)
(Hex) (Non Hex)Fixture Impression Coping (Transfer)
Fixture Lab Analog(Narrow) (Regular) (Wide)
(Hex) (Non Hex)Cemented Abutment
ALIPS Driver ALIPS Screw Abutment Screw 1.2Hex Torque Driver
Angled Abutment (Hex) (Non Hex)UCLA Gold Abutment
(Hex) (Non Hex)UCLA Plastic Abutment
(Hex) (Non Hex)UCLA Temporary Abutment
0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver
Prosthetic Flow Diagrams For EST System
69p
17p 18p
18p
20p
67p 67p
16p16p
14p
16p
20p
19p19p 19p
18p
18p
68p
16 SHINSAEGI MEDI-TECH
3.5 (Narrow)
1.5ESVN350ESVR410ESVW510
4.1 (Regular)
5.1 (Wide)
EST System
- Head height : 1.5mm- Instrumentation required 0.9hex hand driver- Torque recommendation : 5˜8Ncm
01Unit : mm
Fixture Platform Head Height (H) Code
3.5 (Narrow) ESHN350ESHR410ESHW510
4.1 (Regular)
5.1 (Wide)
- Instrumentation required 0.9hex hand driver- Torque recommendation : 5˜8Ncm Unit : mm
Fixture Platform Code
3.5(Narrow) EHAN402 EHAN403 EHAN404 EHAN405 EHAN407
EHAR507EHAR607EHAW607EHAW707EHAW807THAW507THAW607THSW607THSW707
EHAR505EHAR605EHAW605EHAW705EHAW805THAW505THAW605THSW605THSW705
EHAR504EHAR604EHAW604EHAW704EHAW804THAW504THAW604THSW604THSW704
EHAR503EHAR603EHAW603EHAW703EHAW803THAW503THAW603THSW603THSW703
EHAR502EHAR602EHAW602EHAW702EHAW802THAW502THAW602THSW602THSW702
4.0
5.06.06.07.08.05.05.66.06.8
4.1(Regular)
5.1(Wide)
5.0(Wide)T-Type
6.0(Wide)T-Type
- Select the height according to the gingival height (2, 3, 4, 5.5, 7mm)- Healing size marked for easy identification (Emergence profile, Restorative, Height)
- Instrumentation required 1.2hex hand driver- Torque recommendation : 5˜8Ncm
Healing Abutment
Unit : mm
FixturePlatform
Diam-eter(D)
G/H
2 3 4 5.5 7
1.5
G/H
D
Cover Screw
Headless Cover Screw
17SHINSAEGI MEDI-TECH
EST System
02
3.5 (Narrow) M 1.6Ti
Gold
Ti
Gold
Ti
Gold
Hex
Hex
Hex
Hex
Hex
Hex
M 2.0
M 2.5
ESATN35ESAGN35ESATR41ESAGR41ESATW51ESAGW51
4.1 (Regular)
5.1 (Wide)
Unit : mm
Fixture Platform Thread (T) Ti/Gold Type Code
3.5(Narrow)
EACN418H
EACN418N
EACR518H
EACR518N
EACR618H
EACR618N
EACW618H
EACW618N
EACW718H
EACW718N
EACW818H
EACW818N
EACN428H
EACN428N
EACR528H
EACR528N
EACR628H
EACR628N
EACW628H
EACW628N
EACW728H
EACW728N
EACW828H
EACW828N
EACN438H
EACN438N
EACR538H
EACR538N
EACR638H
EACR638N
EACW638H
EACW638N
EACW738H
EACW738N
EACW838H
EACW838N
EACN448H
EACN448N
EACR548H
EACR548N
EACR648H
EACR648N
EACW648H
EACW648N
EACW748H
EACW748N
EACW848H
EACW848N
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
888888888888
4.0
5.0
6.0
6.0
7.0
8.0
4.1(Regular)
5.1(Wide)
- Cemented retained restorations- Height is 8mm with marked groove 6mm and 7mm for easy cutting- Collar height : 1, 2 ,3, 4mm- Packing unit : Included abutment screw
(EACN Series + ESATN35, EACRSeries+ESATR41, EACW Series + ESATW51)- Torque recommendation : 30Ncm
Cemented Abutment
Unit : mm
FixturePlatform
Diameter(D)
G/H
4321
Height(H)
Type
3.4(Narrow)
TACN417H
TACN417N
TACR517H
TACR517N
TACR617H
TACR617N
TACW517H
TACW517N
TACW617H
TACW617N
TACS617H
TACS617N
TACN427H
TACN427N
TACR527H
TACR527N
TACR627H
TACR627N
TACW527H
TACW527N
TACW627H
TACW627N
TACS627H
TACS627N
TACN437H
TACN437N
TACR537H
TACR537N
TACR637H
TACR637N
TACW537H
TACW537N
TACW637H
TACW637N
TACS637H
TACS637N
TACN447H
TACN447N
TACR547H
TACR547N
TACR647H
TACR647N
TACW547H
TACW547N
TACW647H
TACW647N
TACS647H
TACS647N
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
777777777777
3.8
5.0
6.0
5.5
6.0
6.0
4.1(Regular)
5.0(Wide)
6.0
- Cement retained restoration - Combined T-type cemented abutment- Height is fixed 7mm- Packing unit : Included abutment screw(TACN, TACR, TACW Series +ESATR41 or ESAGR41)- Torque recommendation : 30Ncm
Cemented Abutment T-Type
Unit : mm
FixturePlatform
Diameter(D)
G/H
4321
Height(H)
Type
- Instrumentation required 1.2hex Torque driver- For use Cemented Abutment, T-Type Cemented Abutment & Temporary Abutment, UCLA Gold Abutment, UCLA Plastic Abutment
Cemented Abutment Screw
Gold Ti
Gold Ti
Gold Ti
8(H)
D
G/H
76
Hex
7(H)
G/H
Non-Hex
D
Hex
Non-Hex
18 SHINSAEGI MEDI-TECH
EST System
- Cement retained restorations- Angulation : 15 , 25- Collar height : 2mm, 4mm- Packing unit : Included abutment screw(EAAN Series + ESAAN35, EAAR Series + ESAAR41,
EAAW Series + ESAAW51, TAAW Series + ESAAR41) - Torque recommendation : 30Ncm
Angled Abutment03
3.5 (Narrow) 4.0
5.0
6.0
6.0
6.0
2424242424
EAAN4215EAAN4415EAAR5215EAAR5415EAAR6215EAAR6415EAAW6215EAAW6415TAAW6215TAAW6415
EAAN4225EAAN4425EAAR5225EAAR5425EAAR6225EAAR6425EAAW6225EAAW6425TAAW6225TAAW6425
4.1 (Regular)
5.1 (Wide)
5.0(Wide) T-Type
Unit : mm
Fixture PlatformDiameter
(D)G/H
Angel
15 25
Unit : mm
- For use cemented abutment- ALIPS(Anti Lock Inner Post Screw)- Instrumentation required ALIPS driver
3.44.15.0
M 2.0Ti
Gold
Hex
Hex
ESATR41
ESAGR41
Unit : mm
Fixture Platform Thread (T) Ti/Gold Type Code
Cemented Abutment Screw (T-Type)
3.5 (Narrow) M 1.6M 2.0M 2.5
ESAP001ESAP002ESAP003
4.1 (Regular)
5.1 (Wide)
Fixture Platform Thread (T) Code
Unit : mmFixture Lab Analog(UCLA)
3.5 (Narrow) Hex
Hex
Hex
Hex
Hex
ELUN350ELUR410ELUW510TLUW500TLUS600
4.1 (Regular)
5.1 (Wide)
5.0(Wide) T-Type
6.0 (Wide) T-Type
Fixture Platform Type Code
Gold Ti
7
D
G/H
ALIPS Locking Abutment Screw
19SHINSAEGI MEDI-TECH
3.5 (Narrow) ESAAN35ESAAR41ESAAW51
4.1 (Regular)
5.1 (Wide)
04
05
- Screw retained restoration - Gold alloy- Packing unit : Included abutment screw - Torque recommendation : 30Ncm
UCLA Gold Abutment
- Instrumentation required 1.2hex Torque driverAngled Abutment ScrewUnit : mm
Fixture Platform Code
3.5 (Narrow) 4.0
4.5
5.5
5.5
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
EAGN00H
EAGN00N
EAGR00H
EAGR00N
EAGW00H
EAGW00N
TAGW00H
TAGW00N
4.1 (Regular)
5.1 (Wide)
5.0(Wide) T-Type
Unit : mm
Fixture Platform Diameter (D) Type Code
3.5 (Narrow) 4.0
4.5
5.5
5.5
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
EAPN00H
EAPN00N
EAPR00H
EAPR00N
EAPW00H
EAPW00N
TAPW00H
TAPW00N
4.1 (Regular)
5.1 (Wide)
5.0(Wide) T-Type
Unit : mm
Fixture Platform Diameter (D) Type Code
3.5 (Narrow) 4.0
4.5
5.5
5.5
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
ETUN40H
ETUN40N
ETUR50H
ETUR50N
ETUW60H
ETUW60N
TTUW60H
TTUW60N
4.1 (Regular)
5.1 (Wide)
5.0(Wide) T-Type
Unit : mm
Fixture Platform Diameter (D) Type Code
EST System
- Screw retained restoration - Packing unit : Included Abutment Screw- Torque recommendation : 30Ncm
UCLA Plastic Abutment
06 - Temporary restoration- Packing unit : Included abutment screw (ETUN Series+ ESATN35, ETURSeries + ESATR41, ETUWSeries + ESATW51, TTUW Series + ESATR41)
- Torque recommendation : 15Ncm
UCLA Temporary Abutment
Gold Ti
Ti
Ti
D
Hex Non-Hex
D
Hex Non-Hex
D
Hex Non-Hex
20 SHINSAEGI MEDI-TECH
EST System
- Instrument required 1.2hex driverGuide Pin(Pick-up)
- Hex type(Two-piece)- Non hex type(One-piece, Two-piece)
Impression Coping(Transfer)
Narrow 15151715
ESGPN150ESGPR150ESGPR170ESGPW150
Regular
Wide
Unit : mm
Fixture Platform Height (H) Code
Guide Pin(Transfer)
3.5 (Narrow) ESGTN35ESGTR41ESGTW51
4.1 (Regular)
5.1 (Wide)
Unit : mm
Fixture Platform Code
- Length : 12mm- Packing unit : Included guide pin
Impression Coping(Pick-up)07
3.5 (Narrow) 4.0
5.0
6.0
6.0
5.5
6.0
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
EIPN40H
EIPN40N
EIPR50H
EIPR50N
EIPR60H
EIPR60N
EIPW60H
EIPW60N
TIPW55H
TIPW55N
TIPW60H
TIPW60N
4.1 (Regular)
5.1 (Wide)
5.0(Wide) T-Type
Unit : mm
Fixture Platform Diameter (D) Type Code
3.5 (Narrow) 4.5
5.0
6.0
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
EITN45H
EITN45N
EITR50H
EITR50N
EITW60H
EITW60N
4.1 (Regular)
5.1 (Wide)
Unit : mm
Fixture Platform Diameter (D) Type Code
H
D
Hex Non-Hex
D
Hex Non-Hex
21SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For EST System
ALIA EXternal LockingAbutment Screw
1.2Hex Torque Driver Repositioning Jig
Repositioning Jig
Impression Plastic Cap
EXternal YK Transfer Adapter & Screw (EST)
ALIA EXternal Locking Lab Analog(Upper) (Lower)
ALIA EXternal Locking Abutment(Hex)
Screw Retained restoration : Estheticone, Midicone, Widecone, T-Type Widecone Abutment, Locking Abutment.
Fixture(EST)
Conical Abutment(Estheticone, Midicone,
Widecone, Widecone T-Type)
Conical Abutment Screw
Conical Healing Cap
Fixture Lab Analog
Conical Impression Coping (Pick-up)
Conical Impression Coping (Transfer)
0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver
Conical Gold Cylinder Conical Plastic Cylinder Conical Temporary Cylinder
1.2Hex Torque Driver Cylinder Screw
14p
22p
22p
22p
23p 24p
24p
22p 23p 23p
22p
67p
16p16p
16p
67p
25p
25p
25p
25p
68p
69p
24p
69p
68p
22 SHINSAEGI MEDI-TECH
EST System
08 - Screw retained restoration - Collar height : 1, 2, 3, 4mm- Length : Estheticone 1.8mm, Widecone 1.0mm and Midicone 1.0mm- Instrumentation required Estheticone & Midicone 2.0hex driver,
Widecone 2.7hex driver- Packing unit : Included abutment screw(EAE Series + ESE001, EAM Series + ESM001, EAW Series + ESW001, TAW501 Series + TSW001, TAW Series + TSW002)
- Torque recommendation : 30Ncm
Conical Abutment
Estheticone EAE404EAM404EAW504TAW504TAW604
Midicone
Widecone
WideconeT-Type
Estheticone
Midicone
Widecone
WideconeT-Type
Unit : mm
FixturePlatform
Diameter(D)
Height(H)
G/H
4
EAE403EAM403EAW503TAW503TAW603
3
EAE402EAM402EAW502TAW502TAW602
2
EAE401EAM401EAW501TAW501TAW601
1.81.01.01.01.3
4.84.85.55.06.5
1
Conical Abutment Screw
2.02.02.72.02.0
ESE001ESM001ESW001TSW001TSW002
Unit : mm
Fixture Platform Hex Code
Estheticone
Midicone
Widecone
WideconeT-Type
5.55.56.25.06.5
ECE001ECM001ECW001TCW001TCW002
Unit : mm
Fixture Platform Diameter (D) Code
- Instrumentation required 1.2hex driver- Torque recommendation : 20Ncm
- Instrumentation required 1.2hex Torque driver
Conical Healing Cap
- Gold alloy- Packing unit : Included cylinder screw(Estheticone + ESYTE41(ESYGE41), Midicone + ESYTM41(ESYGM41), Widecone + ESYTW51(ESYGW51), Widecone(T) +TSYIW50(TSYGW50))
- Torque recommendation : 20Ncm
Conical Gold Cylinder
Estheticone 4.8
4.8
5.5
5.5
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
EAGE00H
EAGE00N
EAGM00H
EAGM00N
EAGW00H
EAGW00N
TAGW00H
TAGW00N
Midicone
Widecone
WideconeT-Type
Unit : mm
Fixture Platform Diameter (D) Type Code
Gold Ti
H
D
G/H
H
D
D
Hex Non-Hex
23SHINSAEGI MEDI-TECH
Estheticone(Regular)
Midicone(Regular)
Widecone(Wide)
Widecone(Wide) T-Type
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
EIPE00H
EIPE00N
EIPM00H
EIPM00N
EIPW00H
EIPW00N
TIPW00H
TIPW00N
Unit : mm
Fixture Platform Type Product
Estheticone
Midicone
Widecone
WideconeT-Type
Ti
Gold
Ti
Gold
Ti
Gold
Ti
Gold
ESYTE41ESYGE41ESYTM41ESYGM41ESYTW51ESYGW51TSYTW50TSYGW50
Unit : mm
Fixture Platform Type Product
- Packing unit : Included cylinder screw(Estheticone + ESYTE41, Midicone + ESYTM41, Widecone + ESTW51, Widecone(T) + TSYTW50)
- Torque recommendation : 20Ncm
Conical Plastic Cylinder
- Screw retained restoration- Packing unit : Included cylinder screw(Estheticone + ESYTE41, Midicone + ESYTM41, Widecone + ESYTW51, Widecone(T) + TSYTW50)
- Torque recommendation : 20Ncm
Conical Temporary Cylinder
- Instrumentation required 1.2hex Torque driverConical Cylinder Screw
- Packing unit : Included guide pinConical Impression Coping(pick-up)
EST System
Estheticone 4.8
4.8
5.5
5.5
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
EAPE00H
EAPE00N
EAPM00H
EAPM00N
EAPW00H
EAPW00N
TAPW00H
TAPW00N
Midicone
Widecone
WideconeT-Type
Unit : mm
Fixture Platform Diameter (D) Type Code
Estheticone 4.8
5.3
6.0
6.0
6.5
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
ETE001H
ETE001N
ETM001H
ETM001N
ETW001H
ETW001N
TTW001H
TTW001N
TTW002H
TTW002N
Midicone
Widecone
WideconeT-Type
Unit : mm
Fixture Platform Diameter (D) Type Code
Gold Ti
Ti
Ti
D
Hex Non-Hex
D
Hex
Hex
Non-Hex
Non-Hex
24 SHINSAEGI MEDI-TECH
EST System
Estheticone
Midicone
Widecone
WideconeT-Type
813158
13158
13158
1315
ESGE080ESGE130ESGE150ESGM080ESGM130ESGM150ESGW080ESGW130ESGW150TSGW080TSGW130TSGW150
Unit : mm
Fixture Platform Height (H) Product
- Instrument required 1.2hex driverConical Guide Pin(pick-up)
Conical Impression Coping (Transfer)
4.1 (Regular) Estheticone
Midicone
Widecone
Widecone
EITE00N
EITM00N
EITW00N
TITW00N
4.1 (Regular)
5.1 (Wide)
5.0 (Wide) T-Type
Unit : mm
Fixture Platform Type Product
Conical Lab Analog
4.1 (Regular) Estheticone
Midicone
Widecone
Widecone
Widecone
ELEH410ELEL410ELEL510TLEL500TLEL600
4.1 (Regular)
5.1 (Wide)
5.0 (Wide) T-Type
6.0 (Wide) T-Type
Unit : mm
Fixture Platform Type Product
- Screw retained restoration - Hexagon base for anti-rotating locking with a locking abutment screw- Packing unit : Included abutment screw(EALN Series + ESLN Series, EALR Series + ESLR Series, EALW Series +
ESLW Series) ex) EALN401H + ESLN401
- Torque recommendation : 30Ncm
ALIA External Locking Abutment (Hex)09
3.5 (Narrow) EALN404H
EALR504H
EALR604H
EALW604H
EALW704H
EALW804H
TALW604H
TALW704H
TALS604H
TALS704H
4.1 (Regular)
5.1 (Wide)
5.0 (Wide)
6.0 (Wide)
Unit : mm
FixturePlatform
Diameter(D)
Hex(H)
G/H
4
EALN403H
EALR503H
EALR603H
EALW603H
EALW703H
EALW803H
TALW603H
TALW703H
TALS603H
TALS703H
3
EALN402H
EALR502H
EALR602H
EALW602H
EALW702H
EALW802H
TALW602H
TALW702H
TALS602H
TALS702H
2
EALN401H
EALR501H
EALR601H
EALW601H
EALW701H
EALW801H
TALW601H
TALW701H
TALS601H
TALS701H
2.42.72.73.43.43.42.72.72.72.7
4.05.06.06.07.08.06.07.06.07.0
1
H
G/H
Hex
D
25SHINSAEGI MEDI-TECH
3.5 (Narrow) ESLN401ESLR501ESLR601ESLW601ESLW701ESLW801TSLW601TSLW701
ESLN402ESLR502ESLR602ESLW602ESLW702ESLW802TSLW602TSLW702
ESLN403ESLR503ESLR603ESLW603ESLW703ESLW803TSLW603TSLW703
ESLN404ESLR504ESLR604ESLW604ESLW704ESLW804TSLW604TSLW704
4.1 (Regular)
5.1 (Wide)
5.0 (Wide)
3.5 4.0
5.0
6.0
6.0
2.4
2.7
3.4
2.7
1.53.51.53.51.53.51.53.5
4.1
5.1
5.0
3.5
4.1
5.1
5.0
Unit : mm
Fixture PlatformLength(L)
8 9 10 11
- Instrument required 1.2hex Torque driver or Positioning JigExternal Locking Abutment Screw
EST System
ETLN150ETLN350ETLR150ETLR350ETLW150ETLW350TTLW150TTLW350
Unit : mm
Fixture Platform Diameter (D) Hex G/H Code
3.36
3.86
4.86
4.86
9119
119
119
11
ESTLN35S
ESTLN35L
ESTLR41S
ESTLR41L
ESTLW51S
ESTLW51L
TSTLW50S
TSTLW50L
Unit : mm
Fixture Platform Diameter (D) Length (L) Code
- Packing unit : Included External YK Transfer screw- Torque recommendation : 15Ncm
External YK Transfer Adapter
- Instrument required 1.2hex Torque driver or Positioning JigExternal YK Transfer Screw
3.5
4.1
5.1
5.0T-Type
6.0T-Type
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
Upper
Lower
ELLN001ELLN002ELLR001ELLR002ELLW001ELLW002TLLW001TLLW002TLLS001TLLS002
Unit : mm
Fixture Platform Type Code
- Packing unit : Included Upper+LowerExternal Locking Lab Analog
L
L
G/H
Hex
D
(Upper) (Lower)
Impression Plastic CapSIYC 600
Unit : mm
Code
26 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For EST System
Overdenture Retained Restoration for O-Ring Abutment
Fixture(EST)
0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment
O-Ring Abutment
O-Ring Lab Analog
O-Ring Retainer
For Denture O-Ring(Red)
For laboratory O-Ring(Black)
O-Ring Abutment Driver(2.4 Hex)
1.2Hex Hand Driver
67p 67p
16p16p
27p
27p
27p
27p27p
68p
14p
16p
27SHINSAEGI MEDI-TECH
EARR200 EARR300 EARR400 EARR500 EARR6005.04.1(Regular)
- Overdenture restoration- Multiple implant bone retained and fixed removable overdentures- Seating surface diameter 4.1mm- Collar height : 2, 3, 4, 5, 6mm- Instrument required O-Ring Abutment Driver(2.4hex) - Packing unit : Included O-Ring 2ea and O-Ring Retainer 1ea
- Female receptacle processed into denture
Unit : mm
FixturePlatform
Diam-eter(D)
G/H
2.0 3.0 4.0 5.0 6.0
O-Ring Abutment
O-Ring
EST System
10
Red(Denture)
Black(Laboratory)
IARR002IARR003
Unit : mm
Type Code
O-Ring Retainer
IARR001
Unit : mm
Code
O-Ring Lab AnalogRL001
Unit : mm
Code
G/H
D
30 SHINSAEGI MEDI-TECH
SST System
Sub-Cover ScrewSub-Healing AbutmentSub-Solid AbutmentSub-Solid Impression CopingSub-Solid plastic CopingSub-Solid Healing CapSub-Solid Lab AnalogSub-Cemented AbutmentSub-Cemented Abutment ScrewALIPS Locking Abutment ScrewSub-Angled AbutmentSub-Temporary AbutmentSub-Impression Coping (Pick-up)Sub-Impression Coping Guide Pin (Pick-up)Sub-Impression Coping Guide Pin (Transfer)Sub-Impression Coping (Transfer)Sub-Gold AbutmentSub-Fixture Lab AnalogALIA Sub-Locking Abutment (Hex)Sub-Locking Abutment ScrewSub-YK Transfer AdapterSub-YK Transfer ScrewSub-Locking Fixture Lab AnalogSub-O-Ring AbutmentSub-O-RingSub-RetainerSub-O-Ring Lab Analog
34p34p34p35p35p35p35p37p37p37p37p37p38p38p38p38p38p38p40p40p40p40p40p42p42p42p42p
01
02
03
0405
06
07
31SHINSAEGI MEDI-TECH
SU
BM
ER
GE
D (S
ST
)IN
TE
RN
AL
(IST
.IT)
INT
ER
NA
L (IS
T.IT
)E
XT
ER
NA
L (
ES
T)
Submerged Slightly Tapered Fixture (SST System)- SST implant components and ASTRA implant components are fully interchangeable.
The inner of head
Internal Hex connection
Micro groove
- Acheive both soft and hard tissue attachement
- Generate strong attachment of cortical bone
- Superior primary stability
Apex
Sharp tip on 3-cutting edge-This sharp tip also secures a smooth insertion without the implant wobbling
-Implant will not spin and loss stablity when a higher density area in reached
-This thread design make the implant a very efficient selftapping unit.
Body of head
Flapless surgery- Head design is the same diameter as the implant body
- This implant ideal for surgeryNo counter sinking- This makes the surgical
procedure faster and simple.
Body design
Slightly taper-This design for increased initial stablity in soft bone
Unique grooves-Increase stability compared to "v"type thread implant
32 SHINSAEGI MEDI-TECH
Submerged Slightly Tapered Fixture (SST System)
- Submerged Internal Hex connection- Hex : 2.5mm- Apex size : Narrow( 2.25mm), Regular( 2.9mm), Wide( 3.6mm), Wide6.0( 4.3mm)- Torque recommendation : 40Ncm
Unit : mm
Feature
Narrow SST SystemPlatform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Hex(H)
Length(L)
Code
SFSN309
SFSN311
SFSN313
SFSN315
9
11
13
15
2.53.753.83.8
Unit : mmWide6.0 SST SystemPlatform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Hex(H)
Length(L)
Code
SFSW607
SFSW609
SFSW611
SFSW613
7
9
11
13
2.55.96.05.0
Unit : mmRegular SST SystemPlatform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Hex(H)
Length(L)
Code
SFSR407
SFSR409
SFSR411
SFSR413
SFSR415
7
9
11
13
15
2.54.24.34.3
Unit : mmWide SST SystemPlatform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Hex(H)
Length(L)
Code
SFSW507
SFSW509
SFSW511
SFSW513
SFSW515
7
9
11
13
15
2.54.95.05.0
L
D2
D1||
D0
Hex
L
D2
D1||
D0
Hex
L
D2
D1||
D0
Hex
L
D2
D0
D1
Hex
33SHINSAEGI MEDI-TECH
Cement Retained restoration for Sub-Solid Abutment
Fixture(SST)
Sub-Cover Screw Sub-Healing Abutment
1.2Hex Torque Driver Sub-Solid Abutment( 4.5, 5.5, 6.5)
Sub-Solid Healing Cap
Sub-Solid Impression Coping
Sub-Solid Lab Analog
(Single) (Bridge)Sub-Solid Plastic Coping
1.2Hex Hand Driver
Prosthetic Flow Diagrams For SST System
68p
35p
34p
34p 34p
67p
34p
35p
35p
32p
34 SHINSAEGI MEDI-TECH
3.80.5
1.5
SSV001
SSV002
4.35.06.0
SST System
- Head height : 0.5, 1.5mm - Instrumentation required 1.2hex hand driver- Torque recommendation : 5˜8Ncm
Sub-Cover Screw01Unit : mm
Platform Diameter(D) Height (H) Code
- Cement retained restoration- Height is 5.5mm with marked groove 4mm for easy cutting - Collar height : 1.5, 2.5, 3.5, 4.5, 5.5mm and specially SASN series height
1.0, 1.5, 2.5, 3.5, 4.5mm- Profile diameter : 4.5, 5.5, 6.5mm- Instrument required 1.2hex driver- Torque recommendation : 30Ncm
Sub-Solid Abutment02
3.8(Narrow)
4.3(Regular)
5.06.0
(Wide)
- Instrumentation required 1.2hex driver- Torque recommendation : 5˜8Ncm
Sub-Healing AbutmentUnit : mm
FixturePlatform
Diam-eter(D) 1.5
4.5 SHAN4515
-SHAR5515SHAW6515SHAW7515
2.0
-
SHAR5020---
2.5
SHAN4525
-SHAR5525SHAW6525SHAW7525
3.0
-
SHAR5030---
3.5
SHAN4535
-SHAR5535SHAW6535SHAW7535
4.5
SHAN4545
-SHAR5545SHAW6545SHAW7545
5.0
-
SHAR5050---
5.5
SHAN4555
-SHAR5555SHAW6555SHAW7555
5.05.56.57.5
Code
3.8(Narrow)
4.3(Regular)
5.06.0
(Wide)
Unit : mm
FixturePlatform
Diam-eter(D) 5.54.53.52.51.51.0
4.5
5.5
6.5
-
SASR5555
SASW6555
SASN4545
SASR5545
SASW6545
SASN4535
SASR5535
SASW6535
SASN4525
SASR5525
SASW6525
SASN4515
SASR5515
SASW6515
SASN4510
-
-
Code
G/H2
D
5.5
G/H
4
D
4.5
5.5
6.5
4.5
5.5
6.5
4.55.56.5
4.55.56.5
35SHINSAEGI MEDI-TECH
SST System
Sub-Solid Impression Coping
SISC45L
SISC55L
SISC65L
Unit : mm
Diameter (D) Code
SHS45L
SHS55L
SHS65L
Unit : mm
Diameter (D) Code
Sub-Solid plastic Coping
Single
Bridge
Single
Bridge
Single
Bridge
SISP45S
SISP45B
SISP55S
SISP55B
SISP65S
SISP65B
Unit : mm
Diameter (D) Type Code
4.05.54.05.54.05.5
SLSN45S
SLSN45L
SLSR55S
SLSR55L
SLSW65S
SLSW65L
Unit : mm
Diameter (D) Height (H) Code
Sub-Solid Healing Cap
D
Single Bridge
Short Long
Sub-Solid Lab Analog
H
36 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For SST System
Screw & Cement Retained restoration for Sub-Cement Abutment, Sub-Angled Abutment, Sub-TemporaryAbutment, Sub-Gold Abutment
Fixture(SST)
Sub-Cover Screw Sub-Healing Abutment
(Hex) (Non Hex)Sub-Impression Coping (Pick-up)
Sub-Fixture Lab Analog
(Hex) (Non Hex)Sub-Angled Abutment
(Hex) (Non Hex)Sub-Temporary Abutment
(Hex) (Non Hex)Sub-Gold Abutment
(Hex) (Non Hex)Sub-Cemented Abutment
Sub-Abutment Screw 1.2Hex Torque DriverALIPS Locking ScrewALIPS Driver
(Hex) (Non Hex)Sub-Impression Coping (Transfer)
1.2Hex Hand Driver
32p
69p 37p
37p 37p
38p
38p 38p
34p34p
67p
37p 38p
37p
68p
3.84.35.06.0
37SHINSAEGI MEDI-TECH
- For use In-octa cemented abutment - ALIPS(Anti Lock Inner Post Screw)- Instrumentation required ALIPS driver
ALIPS Locking Abutment Screw
Sub-Cemented Abutment Screw
SST System
SSA001
Unit : mm
Code
ISAP001
Unit : mm
Diameter (D) Code
- Instrumentation required 1.2hex Torque driver
- Cement retained restoration - Collar height : 1.5, 2.5, 3.5, 4.5, 5.5mm- Specially SACN series height : 1.0, 2.5, 3.5, 4.5mm- Packing unit : Included abutment screw(SSA001)- Profile diameter : 4.5, 5.5, 6.5mm- Length is 7mm with marked microgroove 4.0mm and 5.5mm for easy cutting- Torque recommendation : 30Ncm
Sub-Cemented Abutment03
3.8(Narrow)
4.3(Regular)
6.0 (Wide)
5.0(Wide)
Unit : mm
FixturePlatform
Diam-eter(D)
Length(L)
Type5.54.53.52.51.51.0
4.55.5
7.0
5.5
7.0
5.5
7.0
5.5
6.5
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
-
-
-
-
SAC5555H
SAC5555N
SACR5555H
SACR5555N
SAC6555H
SAC6555N
SACW6555H
SACW6555N
SAC4545H
SAC4545N
SACN4545H
SACN4545N
SAC5545H
SAC5545N
SACR5545H
SACR5545N
SAC6545H
SAC6545N
SACW6545H
SACW6545N
SAC4535H
SAC4535N
SACN4535H
SACN4535N
SAC5535H
SAC5535N
SACR5535H
SACR5535N
SAC6535H
SAC6535N
SACW6535H
SACW6535N
SAC4525H
SAC4525N
SACN4525H
SACN4525N
SAC5525H
SAC5525N
SACR5525H
SACR5525N
SAC6525H
SAC6525N
SACW6525H
SACW6525N
SAC4515H
SAC4515N
SACN4515H
SACN4515N
SAC5515H
SAC5515N
SACR5515H
SACR5515N
SAC6515H
SAC6515N
SACW6515H
SACW6515N
SAC4510H
SAC4510N
SACN4510H
SACN4510N
-
-
-
-
-
-
-
-
G/H
4 5.5 7 L
G/H
D
Hex Non-Hex
Hex Non-Hex
3.8 (Narrow)
4.3 (Regular)
Unit : mm
FixturePlatform
Diameter(D)
Angle( )
G/H
2.0 4.0
4.5
5.5
15251525
SAAN4152H (N)
SAAN4252H (N)
SAAR5152H (N)
SAAR5252H (N)
SAAN4154H (N)
SAAN4254H (N)
SAAR5154H (N)
SAAR5254H (N)
- Cement retained restorations - Angulation : 15 , 25- Collar height : 2mm, 4mm - Packing unit : Included abutment screw (SSA001)
Sub-Angled Abutment04
1.0
3.0
Hex
Non-Hex
Hex
Non-Hex
STAN4510H
STAN4510N
STAN4530H
STAN4530N
- Packing unit : Included Abutment Screw(SSA001)- Torque recommendation : 30Ncm
Sub-Temporary Abutment05Unit : mm
G/H Type 4.5
7
G/H
D
D
Hex Non-Hex
G/H
4.5
5.5
6.5
4.5
5.5
6.5
38 SHINSAEGI MEDI-TECH
SST System
Sub-Impression Coping Guide Pin (Transfer)
Short
Long
SSGT00S
SSGT00L
Unit : mm
Height (H) Code
Sub-Fixture Lab Analog
SLFR001
Unit : mm
Code
1.0
3.0
Hex
Non-Hex
Hex
Non-Hex
SAGN4510H
SAGN4510N
SAGN4530H
SAGN4530N
SAGN5510H
SAGN5510N
SAGN5530H
SAGN5530N
SAGN6510H
SAGN6510N
SAGN6530H
SAGN6530N
- Packing unit : Included Abutment Screw(SSA001)- Torque recommendation : 30Ncm
Sub-Gold AbutmentUnit : mm
G/H Type 4.5 5.5 6.5
G/H
D
Hex Non-Hex
Sub-Impression Coping Guide Pin (Pick-up)
Short
Long
SSGP00S
SSGP00L
Unit : mm
Height (H) Code
- Packing unit : Included Guide PinSub-Impression Coping (Pick-up)
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Short14Long18Short14Long18Short14Long18Short14Long18Short14Long18Short14Long18
SIPN45HS
SIPN45HL
SIPN45NS
SIPN45NL
SIPR55HS
SIPR55HL
SIPR55NS
SIPR55NL
SIPW65HS
SIPW65HL
SIPW65NS
SIPW65NL
Unit : mm
Fixture Platform Diameter (D) Length (L) Code
H
D
Sub-Impression Coping (Transfer)
Hex
Non-Hex
Hex
Non-Hex
Hex
Non-Hex
Short10Long14Short10Long14Short10Long14Short10Long14Short10Long14Short10Long14
SITN45HS
SITN45HL
SITN45NS
SITN45NL
SITR55HS
SITR55HL
SITR55NS
SITR55NL
SITW65HS
SITW65HL
SITW65NS
SITW65NL
Unit : mm
Fixture Platform Diameter (D) Length (L) Code
Hex Non-Hex
D
Hex Non-Hex
L
39SHINSAEGI MEDI-TECH
Cement & Screw Retained Restoration Component for Sub-Locking Abutment, Sub-Locking Temporary Abutment
Prosthetic Flow Diagrams For SST System
Sub-YK Transfer Adapter & Screw (SST)
Impression Plastic Cap
Repositioning Jig
ALIA Sub-Locking Lab Analog(Upper) (Lower)
ALIA Sub-Locking Abutment Screw Repositioning Jig
ALIA Sub-Locking Abutment
1.2Hex Torque Driver
Fixture(SST)
Sub-Cover Screw Sub-Healing Abutment 1.2Hex Hand Driver
32p
40p
40p
40p
40p
69p
34p34p
67p
68p40p
69p
40 SHINSAEGI MEDI-TECH
SST System
- Screw retained restoration - Hexagon base for anti-rotating locking with a locking abutment screw- Packing unit : Included abutment screw(SALN Series + SSLN Series, SALR Series + SSLR Series, SALW Series + SSLW Series)
- Torque required 30Ncm
ALIA Sub-Locking Abutment (Hex)06
3.8 (Narrow)
4.3 (Regular)
5.0 (Wide)
6.0 (Wide)
Unit : mm
FixturePlatform
Diameter(D)
G/H
SALN4510H
-
-
4.55.5
6.5
1
SALN4515H
SALR5515H
SALW6515H
1.5
SALN4525H
SALR5525H
SALW6525H
2.5
SALN4535H
SALR5535H
SALW6535H
3.5
SALN4545H
SALR5545H
SALW6545H
4.5
- Instrumentation required 1.2Hex Torque driver or reposintiong JigSub-Locking Abutment Screw
Sub-YK Transfer Adapter
3.8 (Narrow)
4.3 (Regular)
5.0 (Wide)
6.0 (Wide)
Unit : mm
FixturePlatform
Length(L)
SSLN4510-
-
8
SSLN4515SSLR5515
SSLW6515
9
SSLN4525SSLR5525
SSLW6525
10
SSLN4535SSLR5535
SSLW6535
11
SSLN4545SSLR5545
SSLW6545
12
1.53.5
STAL150STAL350
Unit : mm
G/H Code
Upper
Lower
SLLR001SLLR002
Unit : mm
Type Code
- Instrumentation required 1.2Hex driver or reposintiong JigSub-YK Transfer Adapter Screw
9
11SSTL090SSTL110
Unit : mm
Height(H) Code
G/H
D
G/H
L
H
Sub-Locking Fixture Lab Analog
(Upper) (Lower)
Impression Plastic CapSIYC 600
Unit : mm
Code
41SHINSAEGI MEDI-TECH
Overdenture Retained Restoration for O-Ring Abutment
Prosthetic Flow Diagrams For SST System
Fixture(SST)
Sub-Cover Screw Sub-Healing Abutment
O-Ring Abutment Driver(2.4Hex)
Sub-O-Ring Abutment
1.2Hex Hand Driver
Sub-O-Ring Lab Analog
Retainer
For Denture O-Ring For Laboratory O-Ring
32p
34p
42p
42p
42p
42p 42p
34p
67p
68p
42 SHINSAEGI MEDI-TECH
SST System
- Overdenture restoration - Multiple implant bone retained and fixed removable overdenture- Collar height : 1, 2, 3, 4mm- Instrument required : O-Ring abutment driver(2.4Hex) - Packing unit : Included O-Ring 2ea, Sub-retainer 1ea- Torque recommendation : 30Ncm
Sub-O-Ring Abutment07
4.55.5
Unit : mm
Diameter(D)
G/H
SARN4510SARR5510
SARN4520SARR5520
SARN4530SARR5530
SARN4540SARR5540
1.0 2.0 3.0 4.0
Sub-O-Ring
Red(Denture)Black(Laboratory)
IARR002IARR003
Unit : mm
Type Code
- Female receptacle processed into dentureSub-Retainer
IARR001
Unit : mm
Code
Sub-O-Ring Lab Analog
RL001
Unit : mm
Code
G/H
D
SHINSAEGI MEDI-TECH 45
SU
BM
ER
GE
D (S
ST
)IN
TE
RN
AL
(IST
.IT)
INT
ER
NA
L (IS
T.IT
)E
XT
ER
NA
L (
ES
T)
Internal Slightly Tapered Fixture (IST System)- IST Implant components and ITI, SWISS PLUS IMPLANT components are fully interchaneable.
The inner of head
Internal octa connection
Micro groove under of head
Positive anchor asosseointegration occusAcheive both soft and hardtissue attachmentSuperior primary stability
Apex
Sharp tip on 3-cutting edge-This sharp tip also secures a smooth insertion without the implant wobbling
-Implant will not spin and loss stablity when a higher density area in reached
-This thread design make the implant a very efficient selftapping unit.
Body of head Esthetic collar
Machined finished collar of1.8mm
Body design
Slightly taper-This design for increased initial stablity in soft bone
Unique grooves-Increase stability compared to "v"type thread implant
46 SHINSAEGI MEDI-TECH
Internal Slightly Tapered Fixture (IST System)
- Internal octa connection- Collar height is fixed 1.8mm- Apex size : Regular( 2.4mm), Wide( 2.6mm), Wide6.0( 4.0mm)- Torque recommendation : 40Ncm
Feature
Unit : mm
Wide6.0 IST System
Platform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Octa(O)
Length(L)
Code
IFSW607
IFSW609
IFSW611
IFSW613
7
9
11
13
3.15.36.06.0
Unit : mm
Regular IST System
Platform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Octa(O)
Length(L)
Code
IFSR407
IFSR409
IFSR411
IFSR413
IFSR415
7
9
11
13
15
3.14.14.84.8
Unit : mm
Wide IST System
Platform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Octa(O)
Length(L)
Code
IFSW507
IFSW509
IFSW511
IFSW513
IFSW515
7
9
11
13
15
3.14.84.84.8
L
1.8 O
D1||
D0
L
1.8 O
L
1.8 O
D2
D1||
D0
D1||
D0
D2
IT & IST System
Cover ScrewHeadless Cover ScrewHealing AbutmentSolid AbutmentSolid Healing CapSolid Impression CopingSolid Positioning CylinderSolid Impression CapSolid Impression Shoulder AnalogSolid Impression Shoulder Analog PinSolid Plastic CopingSolid Lab AnalogExcellent Solid AbutmentExcellent Solid Healing CapExcellent Solid Impression CopingExcellent Solid Positioning CylinderExcellent Solid Impression CapExcellent Solid Impression Shoulder AnalogExcellent Solid Impression Shoulder Analog PinExcellent Solid Plastic CopingExcellent Solid Lab AnalogSolid Angled AbutmentSolid Angled Abutment ScrewIn-Octa Cemented AbutmentIn-Octa Cemented Abutment ScrewALIPS Locking Abutment ScrewIn-Octa Locking Abutment (Octa)In-Octa Locking Abutment ScrewIn-Octa YK Transfer AdapterIn-Octa YK Transfer Adapter ScrewIn-Octa Locking Lab AnalogIn-Octa Gold AbutmentIn-Octa Impression Coping (pick-up)In-Octa Guide Pin(pick-up)In-Octa Impression Coping (Transfer)In-Octa Guide Pin(Transfer)In-Octa Lab AnalogOcta AbutmentOcta Abutment Healing CapOcta Gold CylinderOcta Plastic CylinderOcta Abutment and Cylinder ScrewOcta Impression Coping (pick-up)Guide Pin (pick-up)Octa Lab AnalogO-Ring AbutmentO-RingO-Ring RetainerO-Ring Lab Analog
52p52p52p52p52p53p53p53p53p53p53p54p54p54p54p54p55p55p55p55p55p57p57p57p57p57p58p58p58p58p58p59p59p59p59p59p59p61p61p61p61p62p62p62p62p64p64p64p64p
01
02
03
04
05
06
07
48 SHINSAEGI MEDI-TECH
49SHINSAEGI MEDI-TECH
SU
BM
ER
GE
D (S
ST
)IN
TE
RN
AL
(IST
.IT)
INT
ER
NA
L (IS
T.IT
)E
XT
ER
NA
L (
ES
T)
Internal Tapered Fixture (IT System)- IT implant components and ITI, SWISS PLUS implant components are fully interchangeable.
The inner of head
Internal octa connection
Micro groove under of head
Positive anchor asosseointegration occusAcheive both soft and hardtissue attachmentSuperior primary stability
Apex
- This innovation design is a selftapping tapered implant that provides lateral compression of the osteotomy site to greatly improve primary stability
- This tapered design make the implant a very efficient selftapping unit
Body of head Esthetic collar
Machined finished collar of1.8mm
Body design
This design have a taperedshape similar to roots formrequining less bone removaland less bone augmentation totill the extraction socket
50 SHINSAEGI MEDI-TECH
Internal Tapered Fixture (IT System)
- Internal octa connection- Collar height is fixed 1.8mm- Apex size : Regular( 2.4mm), Wide( 3.1mm), Wide6.0( 3.6mm)- Torque recommendation : 40Ncm
Feature
Unit : mm
Platform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Octa(O)
Length(L)
Code
IFTW607
IFTW609
IFTW611
IFTW613
7
9
11
13
3.15.36.06.0
Unit : mm
Platform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Octa(O)
Length(L)
Code
IFTR407
IFTR409
IFTR411
IFTR413
IFTR415
7
9
11
13
15
3.14.14.84.8
Unit : mm
Platform Diameter
(D0)
Head Diameter
(D1)
Body Diameter
(D2)
Octa(O)
Length(L)
Code
IFTW507
IFTW509
IFTW511
IFTW513
IFTW515
7
9
11
13
15
3.14.84.84.8
Wide6.0 IT System
Regular IT System
Wide IT System
L
1.8 O
D1||
D0
D2
L
1.8 O
D1||
D0
D2
L
1.8 O
D1||
D0
D2
51SHINSAEGI MEDI-TECH
Cement Retained restoration for Solid Abutment, Excellent Solid Abutment
Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)
Cover Screw Headless Cover Screw Healing Abutment
Solid Healing CapExcellent Solid Healing Cap
Solid AbutmentExcellent Solid Abutment
Solid DriverExcellent Solid Driver
Solid Impression CapExcellent Solid Impression Cap
Solid shoulder AnalogExcellent Solid shoulder Analog
Solid shoulder Analog PinExcellent Solid shoulder Analog Pin
Solid Positioning CylinderExcellent Solid Positioning Cylinder
Solid Lab AnalogExcellent Solid Lab Analog
Single(Red) Bridge(White)Solid Plastic Coping
Excellent Solid Plastic Coping
1.2Hex Hand Driver
Prosthetic Flow Diagrams For IST And IT System
46p
52p
52p,54p
52p,54p
53p,55p
53p,55p 53p,55p
55p
53p, 55p
54p
53p,55p
68p
52p 52p
67p
50p
52 SHINSAEGI MEDI-TECH
IST & IT System
- Head height : 1.3mm- Instrumentation required 1.2Hex hand driver- Torque recommendation : 5˜8Ncm
Cover Screw01
02
4.86.0
ISV400ISV600
Unit : mm
Platform Diameter (mm) Code
- Instrumentation required 1.2Hex hand driver- Torque recommendation : 5˜8Ncm
Headless Cover Screw
4.86.0
ISH400
Unit : mm
Platform Diameter (mm) Code
- Profile diameter : 4.8, 5.5, 6.0, 7.0mm- Head height : 2, 3, 4mm- Instrumentation required 1.2hex hand driver- Torque recommendation : 5˜8Ncm
Healing Abutment
4.8
6.0
Unit : mm
PlatformDiameter(mm)
Diameter(D)
G/H
4.85.56.07.0
IHA420IHA520IHA620IHA720
IHA430IHA530IHA630IHA730
IHA440IHA540IHA640IHA740
2 3 4
- It is available in three heights to accommodate vertical requirements(4.0, 5.5, 7.0mm)
- For use in single tooth or multiple unit restoration- Packing unit : Included solid healing cap- Instrumentation required Solid driver- Torque recommendation : 30Ncm
Solid Abutment
4.8
Unit : mm
Platform Diameter(mm)Length (L)
IAS440 IAS455 IAS4704.0 5.5 7.0
- For use protect for solid abutmentSolid Healing Cap
45.57
IHSC440IHSC455IHSC470
Unit : mm
Height (H) Product
G/H
D
L
D
53SHINSAEGI MEDI-TECH
IST & IT System
4.86.0
IISC480IISC600
Unit : mm
Platform Code
4.86.0
IISL480IISL600
Unit : mm
Platform Code
4.86.0
IISN480IISN600
Unit : mm
Platform Code
Solid Positioning Cylinder
4.8
6.0
45.574
5.57
IISY440IISY455IISY470IISY640IISY655IISY670
Unit : mm
Platform Diameter(mm) Height (H) Code
Solid Impression Cap
- Solid positioning cylinder + Solid impression cap = Solid impression copingSolid Impression Coping
45.57
IISI440IISI455IISI470
Unit : mm
Height (H) Code
4.8
6.0
Single(Red)Bridge(White)
Single(Red)Bridge(White)
IISP48S
IISP48B
IISP60S
IISP60B
Unit : mm
Platform Diameter(mm) Color Code
Solid Impression Shoulder Analog
Solid Impression Shoulder Analog Pin
Solid Plastic Coping
D
54 SHINSAEGI MEDI-TECH
IST & IT System
- For use protect for excellent solid abutmentExcellent Solid Healing Cap
4.86.0
Unit : mm
Platform DiameterHeight (H)
IHXC440IHXC640
IHXC455IHXC655
IHXC470IHXC670
4.0 5.5 7.0
- Excellent Solid positioning cylinder + Solid impression cap = Solid impression copingExcellent Solid Impression Coping
4.86.0
Unit : mm
Platform DiameterHeight (H)
IIXI440IIXI640
IIXI455IIXI655
IIXI470IIXI670
4.0 5.5 7.0
4.86.0
Unit : mm
Platform DiameterHeight (H)
IIXY440IIXY640
IIXY455IIXY655
IIXY470IIXY670
4.0 5.5 7.0
4.86.0
Unit : mm
Platform Diameter(D)Height (H)
ILS440ILS640
ILS455ILS655
ILS470ILS670
4.0 5.5 7.0
Excellent Solid Positioning Cylinder
Solid Lab Analog
03 - It is available in three height to accommodate vertical requirements(4.0, 5.5, 7.0mm)
- Instrumentation required 4.8 : Excellent solid driver and 6.0 : 1.2Hex driver
- Packing unit : Included excellent solid healing cap- Torque recommendation : 30Ncm
Excellent Solid Abutment
4.86.0
Unit : mm
Platform DiameterLength (L)
IAX440IAX640
IAX455IAX655
IAX470IAX670
4.0 5.5 7.0
H
L
H
H
H
D
55SHINSAEGI MEDI-TECH
IST & IT System
4.86.0
Unit : mm
Platform Diameter(D)Height (H)
ILX440ILX640
ILX455ILX655
ILX470ILX670
4.0 5.5 7.0
Excellent Solid Impression Cap
4.86.0
IIXC480IIXC600
Unit : mm
Platform Diameter(D) Code
Excellent Solid Impression Shoulder Analog
4.86.0
IIXL480IIXL600
Unit : mm
Platform Diameter(D) Code
Excellent Solid Impression Shoulder Analog Pin
4.86.0
IIXN480IIXN600
Unit : mm
Platform Diameter(D) Code
Excellent Solid Lab Analog
Excellent Solid Plastic Coping
4.8
6.0
Single(Red)
Bridge(White)
Single(Red)
Bridge(White)
IIXP48S
IIXP48B
IIXP60S
IIXP60B
Unit : mm
Platform Diameter Color Code
H
D
D
D
Single Bridge
56 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagrams For IST And IT System
Cement and Screw Retained restoration for In-Octa Cemented Abutment, In-Octa Gold Abutment, Solid Angled Abutment, In-Octa Locking Abutment.
In-Octa Impression Coping(Pick-up)
In-Octa Lab Analog
ALIA In-Octa Locking Lab Analog(Upper) (Lower)
In-Octa Gold Abutment(Octa, Non-Octa)
In-Octa Cement Abutment(Octa, Non-Octa)
ALIPS Driver ALIPS Locking Screw
In-Octa CementedAbutment
Screw
ALIA In-Octa LockingAbutment Screw
1.2Hex Torque Driver
Solid Angled Abutment(Octa)
ALIA In-Octa Locking Abutment
Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)
Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver
46p
52p
69p68p68p58p
57p
59p
59p
57p
57p
57p
57p
52p 52p
58p
58p
58p
58p
69p
67p
50p
In-Octa YK Transfer Adapter & Screw (IST&IT)
Impression Plastic Cap
Repositioning Jig
57SHINSAEGI MEDI-TECH
- Cement retained restoration - Angulation : 15 , 25- Packing unit : Included abutment screw(ISAT001)- Torque recommendation : 30Ncm
Solid Angled Abutment
IST & IT System
04
ISAT001
Unit : mm
Code
1525
IAA150IAA250
Unit : mm
Angle( ) Code
- Cement retained restorations - Collar height : 0, 1, 2, 3, 4mm- For use in single tooth or multiple unit restoration - Packing unit : Included abutment screw (ISCT001)- Torque recommendation : 30Ncm
In-Octa Cemented Abutment05
-Instrumentation required 1.2hex driverSolid Angled Abutment Screw
ISCT001
Unit : mm
Code
- Instrumentation required 1.2hex driverIn-Octa Cemented Abutment Screw
4.8
6.0
Unit : mm
FixturePlatform (D)
TypeG/H
IAC407O
IAC407N
IAC607O
IAC607N
IAC417O
IAC417N
IAC617O
IAC617N
IAC427O
IAC427N
IAC627O
IAC627N
IAC437O
IAC437N
IAC637O
IAC637N
IAC447O
IAC447N
IAC647O
IAC647N
Octa
Non-Octa
Octa
Non-Octa
0 1.0 2.0 3.0 4.0
- For use In-octa cemented abutment- ALIPS(Anti Lock Inner Post Screw)- Instrumentation required ALIPS driver
ALIPS Locking Abutment Screw
4.86.0
ISAP001
Unit : mm
Platform Code
7
75.54
D
Octa Non-Octa
58 SHINSAEGI MEDI-TECH
IST & IT System
6.0 (Wide)
4.8 (Regular)
- Instrumentation required 1.2Hex DriverIn-Octa Locking Abutment ScrewUnit : mm
FixturePlatform
Length (L)
SSLR5515H SSLR5525H SSLR5535H SSLR5545H
SSLW6515H SSLW6525H SSLW6535H SSLW6545H
109 11 12
- Packing unit : Included Upper+LowerIn-Octa Locking Lab Analog
In-Octa YK Transfer Adapter
4.8
6.0
1.53.51.53.5
ITLR150ITLR350ITLW150ITLW350
Unit : mm
Fixture Platform G/H Code
4.8
6.0
UpperLowerUpperLower
ILTL481ILTL482ILTL601ILTL602
Unit : mm
Fixture Platform Type Code
In-Octa YK Transfer Adapter Screw
911
ISTL090ISTL110
Unit : mm
Length (L) Code
6.0 (Wide)
4.8 (Regular)
- Screw retained restoration - Octagone base for antirotation locking with a locking abutment screw- Packing unit : IALR Series + SSLR Series, IALW Series + SSLW Series- Torque required : 30Ncm
In-Octa Locking Abutment (Octa)
Unit : mm
FixturePlatform
Diameter(D)
G/H
IALR515O
IALW615O
IALR525O
IALW625O
IALR535O
IALW635O
5.06.0
1.5 2.5 3.5
D
D
G/H
L
L
(Upper) (Lower)
Impression Plastic CapSIYC 600
Unit : mm
Code
59SHINSAEGI MEDI-TECH
IST & IT System
- Instrumentation required 1.2Hex Driver
- Instrumentation required 1.2Hex Driver
- Gold Alloy- Packing unit : Included abutment screw ISCT001- Torque recommendation : 30Ncm
In-Octa Gold Abutment
4.8
6.0
OctaNon-Octa
OctaNon-Octa
IAGI48O
IAGI48N
IAGI60O
IAGI60N
Unit : mm
Platform Diameter (D) Type Code
In-Octa Impression Coping (Transfer)
4.8
6.0
OctaNon-Octa
OctaNon-Octa
IITI48O
IITI48N
IITI60O
IITI60N
Unit : mm
Platform Diameter Type Code
- Packing unit : Included Guide pinIn-Octa Impression Coping (pick-up)
4.8
6.0
OctaNon-Octa
OctaNon-Octa
IIPI48O
IIPI48N
IIPI60O
IIPI60N
Unit : mm
Platform Diameter Type Code
In-Octa Guide Pin(pick-up)
19 ISGI19O
Unit : mm
Height (H) Code
In-Octa Guide Pin(Transfer)
ISGT100
Unit : mm
Code
In-Octa Lab Analog
4.86.0
ILC400ILC600
Unit : mm
Platform Diameter Code
Octa Non-Octa
Octa Non-Octa
60 SHINSAEGI MEDI-TECH
Prosthetic Flow Diagram For IST And IT System
Screw Retained Restoration Component for Octa Abutment
Octa Driver Octa Abutment
Octa Healing Cap
Octa Lab Analog
(Gold) (Ti)Cylinder Screw
1.2Hex Torque Driver
(Octa) (Non-Octa)Octa Impression Coping(Pick-up)
(Octa) (Non- Octa)Octa Gold Cylinder
(Octa) (Non- Octa)Octa Plastic Cylinder
Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)
Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver
46p
52p 52p
61p
61p
62p
61p 61p
62p
62p
68p
52p
67p
68p
50p
61SHINSAEGI MEDI-TECH
- Screw retained restoration- Instrumentation required octa driver- Torque recommendation : 30Ncm
Octa Abutment
IST & IT System
06
4.86.0
IAO100
Unit : mm
Platform Diameter Code
- For use protect for octa abutment- Included Ti screw(ISOC400)- Instrumentation required 1.2Hex Torque driver- Torque recommendation : 20Ncm
Octa Abutment Healing Cap
4.86.0
ICO400ICO600
Unit : mm
Platform Diameter Code
- Gold alloy- Packing unit : Included abutment screw(ISOC400)- Torque recommendation : 20Ncm
Octa Gold Cylinder
4.8
6.0
Octa
Non-Octa
Octa
Non-Octa
IAGO48O
IAGO48N
IAGO60O
IAGO60N
Unit : mm
Platform Type Product
- Packing unit : Included cylinder screw (ISOC400)- Torque recommendation : 30Ncm
Octa Plastic Cylinder
4.8
6.0
Octa
Non-Octa
Octa
Non-Octa
IAPY48O
IAPY48N
IAPY60O
IAPY60N
Unit : mm
Platform Type Product
Octa Non-Octa
62 SHINSAEGI MEDI-TECH
IST & IT System
- Packing unit : Included guide pinOcta Impression Coping (pick-up)
4.8
6.0
Octa
Non-Octa
Octa
Non-Octa
IIPO48O
IIPO48N
IIPO60O
IIPO60N
Unit : mm
Platform Diameter Type Product
- Instrument required 1.2Hex Torque driverGuide Pin (pick-up)
15 ISGO15O
Unit : mm
Height (H) Product
Octa Lab Analog
4.86.0
ILO40O
ILO60O
Unit : mm
Platform Diameter Product
- Instrument required 1.2Hex Torque driverOcta Abutment and Cylinder Screw
ISOC40O
Unit : mm
Code
Octa Non-Octa
Gold Ti
63SHINSAEGI MEDI-TECH
Overdenture Retained Restoration for O-Ring Abutment
O-Ring Abutment
O-Ring Lab Analog
Retainer
Prosthetic Flow Diagram For IST And IT System
O-Ring Abutment Driver(2.4Hex)
Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)
Internal Cover Screw Internal Headless Cover Screw Healing Abutment 1.2Hex Hand Driver
46p
52p 52p
64p
64p
64p
68p
52p
67p
50p
For Denture O-Ring(Red)
For Laboratory O-Ring(Black)
64p 64p
64 SHINSAEGI MEDI-TECH
IST & IT System
- Overdenture restoration- Multiple implant bone retained and fixed removable overdentures.- Collar height : 0, 2, 4mm- Packing unit : Included O-Ring 2ea and O-Ring retainer 1ea- Instrument required O-Ring abutment driver(2.4Hex)- Torque recommendation : 30Ncm
O-Ring Abutment07
3.5
Unit : mm
Diameter (D)Length (L)
IAR400 IAR420 IAR4400 2.0 4.0
O-Ring
Red(Denture)
Black(Laboratory)
IARR002IARR003
Unit : mm
Type Code
- Female receptacle processed into dentureO-Ring Retainer
IARR001
Unit : mm
Code
O-Ring Lab Analog
RL001
Unit : mm
Code
L
D
Surgical Instrument
66 SHINSAEGI MEDI-TECH
Guide DrillStraight DrillTapered DrillHand DriverMachine DriverTorque DriverFixture Mount DriverDepth gaugeDrill ExtensionLocking Abutment ScrewALIPS DriverPositioning GuideParallel PinTorque WrenchHolding KeyBone Profiler & Guide PinPath PinReamer HandleReamer GuideReamer BiteBone MillTissue PunchDrill SystemSurgical Drilling ProtocolDrill DimensionsSurgical ProtocolSurgical Kit Contents
67p67p67p67p68p68p68p69p69p69p69p69p69p69p69p70p70p70p70p70p70p70p71p71p71p72p74p
67SHINSAEGI MEDI-TECH
- This drill has a unique pointed tip, making this an excellent drill for starting the osteotomy.
Guide Drill
Surgical Instrument
Lance KRG160 Start drill
Unit : mm
Type Code Application
- Tapered series of drills follows in order to increase the width of the osteotomy to correspond to the diameter of the implant being placed.
Tapered Drill
- This drills are designed to increase the depth of the osteotomy.
2.0
79
11131517
KRS2007KRS2009KRS2011KRS2013KRS2015KRS2017
Depth drill
Unit : mm
Diameter Length Code Application
2.0/2.8
2.0/3.3
2.1/3.6
2.5/4.0
2.8/4.5
3.2/4.8
3.3/5.0
4.0/5.8
Short( 7, 9, 11)
Long (13, 15, 17)
Short( 7, 9, 11)
Long (13, 15, 17)
Short( 7, 9, 11)
Long (13, 15, 17)
Short( 7, 9, 11)
Long (13, 15, 17)
Short( 7, 9, 11)
Long (13, 15, 17)
Short( 7, 9, 11)
Long (13, 15, 17)
Short( 7, 9, 11)
Long (13, 15, 17)
Short( 7, 9, 11)
Long (13, 15, 17)
KRT2028S
KRT2028L
KRT2033S
KRT2033L
KRT2136S
KRT2136L
KRT2540S
KRT2540L
KRT2845S
KRT2845L
KRT3248S
KRT3248L
KRT3350S
KRT3350L
KRT4058S
KRT4058L
Width increasing drill
Unit : mm
Diameter Length Code Application
- For use tip-holding function by handHand Driver
External 1.2Hex
External 0.9Hex
Short
Long
Short
Long
KDH120S
KDH120L
KDH090S
KDH090L
Healing abutment, UCLA Abutment screw, Internal cover screw
External cover screw(N, R, W, W6.0)
Unit : mm
Diameter Length Code Application
Straight Drill
1.2Hex 0.9Hex
68 SHINSAEGI MEDI-TECH
Surgical Instrument
- For use Torque Wrench- For use Torque function
External 1.2Hex
External 0.9Hex
Internal 2.0Hex
Internal 2.4Hex
Internal 2.7Hex
Solid Driver
Ex-Solid Driver
Octa Driver
Short
Long
Short
Long
Short
Long
Short
Long
Short
Long
Short
Long
Short
Long
Short
Long
KDT120S
KDT120L
KDT090S
KDT090L
KDT200S
KDT200L
KDT240S
KDT240L
KDT270S
KDT270L
KDTS00S
KDTS00L
KDTE00S
KDTE00L
KDT300S
KDT300L
Healing abutment, UCLA Abutment screw, Internal cover screw
External cover screw(N, R, W, W6.0)
Estheticone and Midicone Abutment screw
All of O-Ring Abutment
Widecone Abutment screw
Solid Abutment
Excellent Solid Abutment
Octa Abutment
Unit : mm
Diameter Length Code Application
- For pick-up and delivery of Implant
Narrow( 3.5)Hand piece
Regular( 4.1)Hand piece
Wide( 5.1)Hand piece
Narrow( 3.5)Ratchet
Regular( 4.1)Ratchet
Wide( 5.1)Ratchet
All of Size(Sub)Hand piece
All of Size(Sub)Ratchet
All of Size(Internal)Hand piece
All of Size(Internal)Ratchet
Hex
Hex
Hex
Hex
Hex
Hex
Hex
Hex
Octa
Octa
Long
Long
Long
Short
Long
Short
Long
Short
Long
Long
Short
Long
Long
Short
Long
KDMM240L
KDMM270L
KDMM340L
KDTM240S
KDTM240L
KDTM270S
KDTM270L
KDTM340S
KDTM340L
KDMM250L
KDTM250S
KDTM250L
KDMM310L
KDTM310S
KDTM310L
For use External implant(EST Series)
For use Submerged Implant(SST Series)
For use Internal implant(IST&IT Series)
Unit : mm
Diameter Length Length Code Application
- For use hand-piece of Motor
External 1.2Hex
External 0.9Hex
Short
Long
Short
Long
KDM120S
KDM120L
KDM090S
KDM090L
Healing abutment, UCLA Abutment screw, Internal cover screw
External cover screw(N, R, W, W6.0)
Unit : mm
Diameter Length Code Application
Fixture Mount Driver
Torque Driver
Machine Driver
1.2Hex
External Type
Interal Type
Modrine
Torque
EST
EST SST IST & IT
SST IST & IT
0.9Hex
69SHINSAEGI MEDI-TECH
Surgical Instrument
- Measurement of drilling depth(EST, SST, IST, IT Implant)
7, 9, 11, 13, 15, 17 KID170
Unit : mm
Depth Length Code
- Using for insert implant and tie-up driver
15, 25, 35 Ncm KIT450
Unit : mm
Torque Power Code
- Measurement of fixture space
810
KIG080KIG100
Unit : mm
Unit : mm
Width(D) Code
- Measurement of direction and situation
45
KIP400KIP500
Unit : mm
Width(D) Code
- For use drill extension on hand-piece
KIE300
Unit : mm
Code
Depth gauge
Positioning Guide
Parallel Pin
Torque Wrench
Drill Extension
- For use locking abutment screw
KDHAL110
Unit : mm
Code
Repositioning Jig
- For use ALIPS abutment
KDHAP130Code
ALIPS Driver
- Holding for Torque Wrench
KIK850
Unit : mm
Code
Holding Key
D
D
70 SHINSAEGI MEDI-TECH
Surgical Instrument
Reamer Bite
KIRB
Unit : mm
Code
- For formation of particulate bone with autogenous bone.Bone Mill
KIBM
Unit : mm
Code
- Flapless surgery- Laser marking 2, 4, 6mm for easy measurement of gingiva height.
4.14.65.36.3
KICM410KICM460KICM530KICM630
EST, SST(Narrow)
EST, IT, IST, SST(Regular)
EST, IT, IST, SST(Wide)
EST, SST(Wide 6.0)
Unit : mm
D Code Application
Tissue Punch
4.55.56.5
KIRG450KIRG550KIRG650
Unit : mm
Width Code
- Measurement of path and gingival height
KIH250
Unit : mm
Code
Path Pin
KIRH
Unit : mm
Code
Reamer Handle
Reamer Guide
- For remove from surplus bone
3.64.155.156.054.85
KIBN360KIBR415KIBW515KIBW605KIBW485
Unit : mm
Fixture platform Interface Diameter Code
Bone Profiler & Guide Pin
3.5 (Narrow)
4.1 (Regular)
5.1 (Wide)
6.0 (W6.0)
4.8 (N, R, W)
71SHINSAEGI MEDI-TECH
Drill System
Drill (Straight & Tapered Drill)
Surgical Drilling Protocol
Drill Dimensions
Tapered Drill ( 2.0/2.8) ( 2.0/3.3) ( 2.1/3.6) ( 2.5/4.0) ( 2.8/4.5) ( 3.2/4.8) ( 3.3/5.0) ( 4.0/5.8) (mm)A series of tapered drills are width drill in order to increase the width of the osteotomy to correspond to the diameter of the implant being placed.Regardless of the tapered drills diameter, the length of the drill tip is 0.3mmThe length of the drill tip is not included in the depth mark measurement.
Straight Drill( 2.0)Proceed with the initial straight drill to 7mm, 9mm, 11mm, 13mm, 15mm, 17mm with stopper.
2.0mm is designed to increase the depth of the osteotomy.Thread floss through the hole to prevent accidental swallowing.
2.0 straight drills, the length of the drill tip is 0.5mm.The length of the drill tip is not included in the depth mark
measurement.Consist of the diameter 2.0mm straight drills are 7. 9. 11, 13, 15, 17mm length with stopper and not marking system.
EST
3.54.14.15.13.84.35.06.04.84.86.0
3.44.05.05.93.74.24.95.94.14.85.3
2.42.93.64.32.42.93.64.3
2.4 3.43.4 4.14.0 4.6
SST
ISTIT
Product
2.0mm(straight)
2.0/2.8mm(tapered)
2.0/3.3mm(tapered)
2.1/3.6mm(tapered)
0.5mm
7mm(with stopper)
9mm(with stopper)
11mm(with stopper)
13mm(with stopper)
15mm(with stopper)
17mm(with stopper)
7, 9, 11mm(marking with stopper)
13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper)
13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper)
13, 15, 17mm(marking)
0.3mm
2.5/4.0mm(tapered)
2.8/4.5mm(tapered)
3.2/4.8mm(tapered)
3.3/5.0mm(tapered)
4.0/5.8mm(tapered)
-
0.3mm
0.3mm
0.3mm
0.3mm
0.3mm
-
7, 9, 11mm(marking with stopper)
13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper)
13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper)
13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper)
13, 15, 17mm(marking)
7, 9, 11mm(marking with stopper)
13, 15, 17mm(marking)
-
0.3mm
0.3mm
Drill DiameterDrill TipLength
Drill Length Drill DiameterDrill TipLength
Drill Length
Platform Body Apex Guide 2.0 2.0/2.8 2.0/3.3 2.1/3.6 2.5/4.0 2.8/4.5 3.2/4.8 3.3/5.0 4.0/5.8
Guide Drill Tapered DrillStraight Drill
72 SHINSAEGI MEDI-TECH
Surgical Protocol
External Slightly Tapered Fixture (EST System)
: Guide 2.0mm Straight Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture
D4BoneD3,D2BoneD1Bone
3.4mm Fixture01
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.0/3.3mm Tapered Drill
Fixture0.5mm
4.0mm Fixture
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.5/4.0mm Tapered Drill
Fixture0.5mm
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture
D4BoneD3,D2BoneD1Bone
02
5.0mm Fixture
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill
Fixture0.5mm
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill Fixture
D4BoneD3,D2BoneD1Bone
03
5.9mm Fixture
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.8/4.5mm Tapered Drill
3.3/5.0mm Tapered Drill
4.0/5.8mm Tapered Drill
Fixture0.5mm
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.3/5.0mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.3/5.0mm Tapered Drill 4.0/5.8mm Tapered Drill Fixture
D4BoneD3,D2Bone
D1Bone
04
73SHINSAEGI MEDI-TECH
Surgical Protocol
Submerged Slightly Tapered Fixture (SST System)
3.7mm Fixture01
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.0/3.3mm Tapered Drill
2.1/3.6mm Tapered Drill
Fixture0.5mm
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture
D4BoneD3,D2BoneD1Bone
4.2mm Fixture02
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.5/4.0mm Tapered Drill
Fixture0.5mm
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture
D4BoneD3,D2BoneD1Bone
4.9mm Fixture03
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill
Fixture0.5mm
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill Fixture
D4BoneD3,D2BoneD1Bone
5.9mm Fixture
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.8/4.5mm Tapered Drill
3.3/5.0mm Tapered Drill
4.0/5.8mm Tapered Drill
Fixture0.5mm
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture
3.3/5.0mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.3/5.0mm Tapered Drill 4.0/5.8mm Tapered Drill Fixture
D4BoneD3,D2Bone
D1Bone
04
74 SHINSAEGI MEDI-TECH
Surgical Protocol
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill
3.3/5.0mm Tapered Drill
0.5mm
Internal Slightly Tapered Fixture (IST System)Internal Tapered Fixture(IT System)
4.1mm Fixture01
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.5/4.0mm Tapered Drill
Fixture(IST)
Fixture(IT)
0.5mm
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture
- IST & IT model are same diameter and same protocol.
D4BoneD3,D2BoneD1Bone
4.8mm Fixture02
Fixture(IST)
Fixture(IT)
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill
2.8/4.5mm Tapered Drill Fixture
D4BoneD3,D2BoneD1Bone
15mm
Guide 2.0mmStraight Drill
2.0/2.8mm Tapered Drill
2.1/3.6mm Tapered Drill
2.5/4.0mm Tapered Drill
2.8/4.5mm Tapered Drill
0.5mm
5.3mm Fixture03
Fixture(IST)
Fixture(IT)
: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill
3.2/4.8mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill
3.2/4.8mm Tapered Drill 3.3/5.0mm Tapered Drill Fixture
D4BoneD3,D2Bone
D1Bone
76 SHINSAEGI MEDI-TECH
Surgical Kit Contents
External Kit(EST)No Type Length Q'Ty Application
Guide Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0/2.8 Tapered Drill(S)2.0/2.8 Tapered Drill(L)2.0/3.3 Tapered Drill(S)2.0/3.3 Tapered Drill(L)2.1/3.6 Tapered Drill(S)2.1/3.6 Tapered Drill(L)2.5/4.0 Tapered Drill(S)2.5/4.0 Tapered Drill(L)3.2/4.8 Tapered Drill(S)3.2/4.8 Tapered Drill(L)3.3/5.0 Tapered Drill(S)3.3/5.0 Tapered Drill(L)4.0/5.8 Tapered Drill(S)4.0/5.8 Tapered Drill(L)
Drill extensionFixture Mount Driver(Machine) NarrowFixture Mount Driver(Machine) RegularFixture Mount Driver(Machine) WideFixture Mount Driver(Torque) Narrow(L)Fixture Mount Driver(Torque) Narrow(S)Fixture Mount Driver(Torque) Regular(L)Fixture Mount Driver(Torque) Regular(S)Fixture Mount Driver(Torque) Wide(L)Fixture Mount Driver(Torque) Wide(S)Hex 0.9 Driver for Hand(L)Hex 0.9 Driver for Hand(S)Hex 0.9 Driver for Machine(L)Hex 0.9 Driver for Machine(S)Hex 0.9 Driver for Torque(L)Hex 0.9 Driver for Torque(S)Hex 1.2 Driver for Hand(L)Hex 1.2 Driver for Hand(S)Hex 1.2 Driver for Machine(L)Hex 1.2 Driver for Machine(S)Hex 1.2 Driver for Torque(L)Hex 1.2 Driver for Torque(S)Hex 2.0 Driver(L)Hex 2.0 Driver(S)Hex 2.7 Driver(L)Hex 2.7 Driver(S)Hex 2.4 Driver(L)Hex 2.4 Driver(S)
7mm9mm
11mm13mm15mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm
11111111111111111111111111111111111111111111111111111111
Start DrillDepth DrillDepth DrillDepth DrillDepth DrillDepth DrillDepth DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillFor use drill and handpiece tools extensionMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for External
External Cover Screw(N, R, W, W6.0)
Abutment ScrewHealing Abutment, Locking Abutment Screw,Cylinder Screw
For Estheticone, MidiconeFor Estheticone, MidiconeFor WideconeFor WideconeFor O-RingFor O-RingMeasurement of direction and situationMeasurement of direction and situationMeasurement of fixture spaceMeasurement of fixture spaceInsert implant and tie-up driverHolding for Torque WrenchMeasurement of drilling depth
1
2
34567891011121314151617181920212223242526272829303132333435363738394041424344
45
46
Parallel Pin
Positioning Guide
Torque Wrench 45N cmHolding KeyDepth Gauge
4mm5mm8mm
10mm
7~17mmTotal 56
474849
No Type Length Q'Ty Application
Guide Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0/2.8 Tapered Drill(S)2.0/2.8 Tapered Drill(L)2.0/3.3 Tapered Drill(S)2.0/3.3 Tapered Drill(L)2.1/3.6 Tapered Drill(S)2.1/3.6 Tapered Drill(L)2.5/4.0 Tapered Drill(S)2.5/4.0 Tapered Drill(L)2.8/4.5 Tapered Drill(S)2.8/4.5 Tapered Drill(L)3.2/4.8 Tapered Drill(S)3.2/4.8 Tapered Drill(L)3.3/5.0 Tapered Drill(S)3.3/5.0 Tapered Drill(L)
Drill extensionFixture Mount Driver for Machine(Hex)(L)Fixture Mount Driver for Torque (L)Fixture Mount Driver for Torque (S)Fixture Mount Driver for Machine(Octa)(L)Fixture Mount Driver for Torque (L)Fixture Mount Driver for Torque (S)Hex 1.2 Driver for Hand(L)Hex 1.2 Driver for Hand(S)Hex 1.2 Driver for Machine(L)Hex 1.2 Driver for Machine(S)Hex 1.2 Driver for Torque(L)Hex 1.2 Driver for Torque(S)Octa Driver for Torque(L)Octa Driver for Torque(S)Solid Driver for Torque(L)Solid Driver for Torque(S)Excellent Solid Driver for Torque(L)Excellent Solid Driver for Torque(S)Hex 2.4 Driver for Torque(L)Hex 2.4 Driver for Torque(S)
7mm9mm11mm13mm15mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm
1111111111111111111111111111111111111111111111111
Start DrillDepth DrillDepth DrillDepth DrillDepth DrillDepth DrillDepth DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillFor use drill and handpiece tools extensionMountless delivery for Internal Hex(SST)Mountless delivery for Internal Hex(SST)Mountless delivery for Internal Hex(SST)Mountless delivery for Internal Octa(IST/IT)Mountless delivery for Internal Octa(IST/IT)Mountless delivery for Internal Octa(IST/IT)Cover Screw, Abutment ScrewHealing Abutment,
6.0 Excellent Solid Abutment,Locking Abutment Screw,In-Octa Cemented Abutment,Sub Solid Abutment, Cylinder Screw
Octa Abutment
Solid Abutment
Excellent Solid Abutment
O-Ring Abutment
Measurement of direction and situation
Measurement of fixture space
Insert implant and tie-up driverHolding for Torque WrenchMeasurement of drilling depth
1
2
3456789
10111213141516171819202122232425262728293031323334353637
38
39
404142
Parallel Pin
Positioning Guide
Torque Wrench 45N cmHolding KeyDepth Gauge
4mm5mm8mm10mm
7~17mmTotal 49
Internal Kit(SST, IST, IT)
No Type Length Q'Ty Application
Bone Profile and Guide Pin
Path PinReamer Handle
Reamer Guide
Reamer BiteBone Mill
Tissue punch
3.64.155.156.054.85
4.55.56.5
4.14.65.36.3
1111111111111111
For remove from surplus bone.
Measurement of path and height gingiva
For Particulate bone generation by autogenous bone.Flaplees Surgery for EST, SST (Narrow)Flaplees Surgery for EST, IT, IST, SST(Regular)Flaplees Surgery for EST, IT, IST, SST(Wide)Flaplees Surgery for EST, SST(Wide 6.0)
1
2
3
4
56
7
Total 16
Option