dental implant system · 02 shinsaegi medi-tech view of company work flow concept of cad/cam system...

76
1 SHINSAEGI MEDI-TECH Dental Implant System Esthetic & Innovation SHINSAEGI MEDI-TECH Co., Ltd.

Upload: buiquynh

Post on 03-Apr-2018

219 views

Category:

Documents


2 download

TRANSCRIPT

1SHINSAEGI MEDI-TECH

Dental Implant SystemEsthetic & Innovation

SHINSAEGI MEDI-TECH Co., Ltd.

02 SHINSAEGI MEDI-TECH

View of company

Work Flow Concept of CAD/CAM System

Packing design Un-packing Protocol

ALIA Locking Abutment ALIPS Locking Abutment Screw

Mountless driver system Length of the implant(EST, SST, IST, IT)

Introduction of SG Implant

EST System

- External Slightly Tapered Fixture(EST)

- Prosthetic Flow diagrams and components for Cemented Abutment, Angled Abutment, UCLA Gold Abutment, UCLA Plastic Abutment, Temporary Abutment.

- Prosthetic Flow diagrams and components for Estheticone, Midicone, Widecone, Locking Abutment.

- Prosthetic Flow diagrams and components for O-Ring Abutment.

SST System

- Internal Submerged Slightly Tapered Fixture(SST)

- Prosthetic Flow diagrams and components for Sub-Solid Abutment.

- Prosthetic Flow diagrams and components for Sub-Cemented Abutment, Sub-Angled Abutment, Sub-Temporary Abutment, Sub-Gold Abutment.

- Prosthetic Flow diagrams and components for Sub-Locking Abutment.

- Prosthetic Flow diagrams and components for Sub-O-Ring Abutment.

IST System

- Internal Slightly Tapered Fixture(IST)

IT System

- Internal Tapered Fixture(IT)

- Prosthetic Flow diagrams and components for Solid Abutment, Excellent Solid Abutment.

- Prosthetic Flow diagrams and components for In-Octa Cemented Abutment, In-Octa Gold Abutment, Solid Angled Abutment, In-Octa Locking Abutment.

- Prosthetic Flow diagrams and components for Octa Abutment.

- Prosthetic Flow diagrams and components for O-Ring Abutment.

Surgical Instrument

- Surgical Instrument for EST, SST, IST, IT

- Drill system

- Surgical Drilling protocol and Dimensions

- Surgical protocol for EST, SST, IST, IT

- Surgical kit contents

03040506070811

29

43

47

65

CONTENTS

03SHINSAEGI MEDI-TECH

View of company

Company : SHINSAEGI Medi-Tech Co., Ltd.

Head office & Manufacture Address :

Busan-city, Gang Seu-Gu, Ji Sa-Dong 1212, Korea

TEL : 82-51-971-2811 FAX : 82-51-971-2814

E-mail : [email protected]

Business : Medical Instrument Manufacture & Marketing

Product :

Dental Implant (Manufacture&Marketing)

Dental CAD/CAM (Manufacture&Marketing)

Titanium & Stainless (Import & Marketing)

Dental Materials & Instrument (Manufacture & Marketing)

Homepage : http://sgimplant.com

04 SHINSAEGI MEDI-TECH

Work Flow Concept of CAD/CAM System

Preparation Model Preparation Scanning

Sintering Milling M/C Design

Veneering Cementation Scanning

05SHINSAEGI MEDI-TECH

This Ampule has been divided color for easyNarrow(Red) Regular(Yellow) Wide(Green) Wide 6.0(Blue)

Narrow Regular Wide Wide 6.0

Packing design

Implant Un-packing Protocol

1 2Peel back thetray lid to exposethe implant.

Removecontents fromthe implantbox.

3 4 5Pick-up theimplant from thesurgical ampuleusing the fixturemount driver.

Draw open acover of implant.

Mountlessdelivery systemfor easy andsafety.

06 SHINSAEGI MEDI-TECH

This innovate Locking Abutment released from Screw loosening. [ Patent No. US 7.393.210 B2 ]

ALIA Locking Abutment

ALIPS Locking Abutment Screw

ALIPS (Anti Lock Inner Post Screw) [ Patent No. US 6.857.874 B2 ]

External Hex Type(EST)

Submerged Internal Hex Type(SST)

Internal Octa Type(IST&IT)

External Hex Type(EST)

Submerged Internal Hex Type(SST)

Internal Octa Type(IST&IT)

07SHINSAEGI MEDI-TECH

EST SST IST IT

1.8 mm

Length(L) 7, 9, 11, 13, 15mm

0.75 mm

- Care must be taken when inserting the implant placement driver tip into the implant.- A very low RPM speed must be used as you approach the internal hex and octa connection and external hex

connection of the implant with the driver tip.

- Regardless of the implant type, the length of the implant is the same from the top of the implant collar(platform) to the tip of the implant.

Pick-up and delivery of implant

Mountless driver system

Length of the implant(EST, SST, IST, IT)

External Hex Type(EST)

Submerged Internal Hex Type(SST)

Internal Octa Type(IST&IT)

08 SHINSAEGI MEDI-TECH

Introduction of SG Implant

External Slightly Tapered Fixture (EST)

No Code

EFSN309EFSN311EFSN313EFSN315

EFSR407EFSR409EFSR411EFSR413EFSR415

EFSW507EFSW509EFSW511EFSW513EFSW515

3.53.53.53.5

4.14.14.14.14.1

5.15.15.15.15.1

5.05.05.05.05.0

3.43.43.43.43.4

3.43.43.43.43.4

4.04.04.04.04.0

3.43.43.43.4

9.011.013.015.0

7.09.0

11.013.015.0

7.09.0

11.013.015.0

2.72.72.72.72.7

2.62.62.62.62.6

2.42.42.42.4

2.22.22.22.2

1234

56789

1011121314

EFSW607EFSW609EFSW611EFSW613

5.15.15.15.1

5.95.95.95.9

3.43.43.43.4

4.54.54.54.5

7.09.0

11.013.0

15161718

Size (mm)

DiameterD0

DiameterD1

LengthL0

HexH

ApexA

No Code

SFSN309SFSN311SFSN313SFSN315

SFSR407SFSR409SFSR411SFSR413SFSR415

SFSW507SFSW509SFSW511SFSW513SFSW515

3.83.83.83.8

4.34.34.34.34.3

5.05.05.05.05.0

4.94.94.94.94.9

2.52.52.52.52.5

3.63.63.63.63.6

4.24.24.24.24.2

3.753.753.753.75

9.011.013.015.0

7.09.0

11.013.015.0

7.09.0

11.013.015.0

2.52.52.52.52.5

2.92.92.92.92.9

2.52.52.52.5

2.22.22.22.2

1234

56789

1011121314

SFSW607SFSW609SFSW611SFSW613

6.06.06.06.0

5.95.95.95.9

2.52.52.52.5

4.34.34.34.3

7.09.0

11.013.0

15161718

Size (mm)

DiameterD0

DiameterD1

LengthL0

HexH

ApexA

D0

D1

A

L0

H

D0

D1

A

L0

H

Submerged Slightly Tapered Fixture(SST)

09SHINSAEGI MEDI-TECH

Internal Slightly Tapered Fixture(IST)

No Code

IFSR407IFSR409IFSR411IFSR413IFSR415

IFSW507IFSW509IFSW511IFSW513IFSW515

4.84.84.84.84.8

4.84.84.84.84.8

4.84.84.84.84.8

3.13.13.13.13.1

2.62.62.62.62.6

4.14.14.14.14.1

7.09.0

11.013.015.0

7.09.0

11.013.015.0

3.13.13.13.13.1

2.42.42.42.42.4

12345

6789

10

IFSW607IFSW609IFSW611IFSW613

6.06.06.06.0

5.35.35.35.3

3.13.13.13.1

4.04.04.04.0

7.09.0

11.013.0

11121314

Size (mm)

DiameterD0

DiameterD1

LengthL0

OctaO

ApexA

No Code

IFTR407IFTR409IFTR411IFTR413IFTR415

IFTW507IFTW509IFTW511IFTW513IFTW515

4.84.84.84.84.8

4.84.84.84.84.8

4.84.84.84.84.8

3.13.13.13.13.1

3.13.13.13.13.1

4.14.14.14.14.1

7.09.0

11.013.015.0

7.09.0

11.013.015.0

3.13.13.13.13.1

2.42.42.42.42.4

12345

6789

10

IFTW607IFTW609IFTW611IFTW613

6.06.06.06.0

5.35.35.35.3

3.13.13.13.1

3.63.63.63.6

7.09.0

11.013.0

11121314

Size (mm)

DiameterD0

DiameterD1

LengthL0

OctaO

ApexA

Internal Tapered Fixture(IT)

D0

D1

A

L0

1.8

O

D0

D1

A

L0

1.8

O

Introduction of SG Implant

10 SHINSAEGI MEDI-TECH

11SHINSAEGI MEDI-TECH

External

FixtureEsthetic & Innovation

SHINSAEGI MEDI-TECH

EST System

12 SHINSAEGI MEDI-TECH

Cover ScrewHeadless Cover ScrewHealing AbutmentCemented AbutmentCemented Abutment T-TypeCemented Abutment ScrewCemented Abutment Screw (T-Type)ALIPS Locking Abutment ScrewFixture Lab Analog(UCLA)Angled AbutmentAngled Abutment ScrewUCLA Gold AbutmentUCLA Plastic AbutmentUCLA Temporary AbutmentImpression Coping(Pick-up)Guide Pin(Pick-up)Impression Coping(Transfer)Guide Pin(Transfer)Conical AbutmentConical Abutment ScrewConical Healing CapConical Gold CylinderConical Plastic CylinderConical Temporary CylinderConical Cylinder ScrewConical Impression Coping(pick-up)Conical Guide Pin(pick-up)Conical Impression Coping (Transfer)Conical Lab AnalogALIA External Locking Abutment (Hex)External Locking Abutment ScrewExternal YK Transfer AdapterExternal YK Transfer ScrewImpression Plastic CapExternal Locking Lab AnalogO-Ring AbutmentO-RingO-Ring RetainerO-Ring Lab Analog

16p16p16p17p17p17p18p18p18p18p19p19p19p19p20p20p20p20p22p22p22p22p23p23p23p23p24p24p24p24p25p25p25p25p25p27p27p27p27p

01

02

03

04050607

08

09

10

13SHINSAEGI MEDI-TECH

External Slightly Tapered Fixture(EST System)EST Implant components and Branemark, 3i, implant components are fully interchangeable.

SU

BM

ER

GE

D (S

ST

)IN

TE

RN

AL

(IST

.IT)

INT

ER

NA

L (IS

T.IT

)

The inner of head

External Hex connectionHex height-0.75mm

Micro groove

- Acheive both soft and hard tissue attachement

- Generate strong attachment of cortical bone

- Superior primary stability

Apex

Sharp tip on 3-cutting edge-This sharp tip also secures a smooth insertion without the implant wobbling

-Implant will not spin and loss stablity when a higher density area in reached

-This thread design make the implant a very efficient selftapping unit.

Body of head

Flapless surgery- Head design is the same diameter as the implant body

- This implant ideal for surgeryNo counter sinking- This makes the surgical

procedure faster and simple.

Body design

Slightly taper-This design for increased initial stablity in soft bone

Unique grooves-Increase stability compared to "v"type thread implant

EX

TE

RN

AL

(E

ST

)

14 SHINSAEGI MEDI-TECH

External Slightly Tapered Fixture (EST System)

- Submerged External hex connection (Hex height 2.7mm)- Apex size : Narrow( 2.2mm), Regular( 2.6mm), Wide( 3.4mm), Wide6.0( 4.5mm)- Torque recommendation : 40Ncm

Unit : mm

Feature

Narrow EST SystemPlatform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Hex(H)

Length(L)

Code

EFSN309

EFSN311

EFSN313

EFSN315

9

11

13

15

2.43.43.53.5

Unit : mmWide6.0 EST SystemPlatform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Hex(H)

Length(L)

Code

EFSW607

EFSW609

EFSW611

EFSW613

7

9

11

13

3.45.96.05.1

Unit : mmRegular EST SystemPlatform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Hex(H)

Length(L)

Code

EFSR407

EFSR409

EFSR411

EFSR413

EFSR415

7

9

11

13

15

2.74.04.14.1

Unit : mmWide EST SystemPlatform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Hex(H)

Length(L)

Code

EFSW507

EFSW509

EFSW511

EFSW513

EFSW515

7

9

11

13

15

3.45.05.15.1

L

D2

D1||

D0

Hex

L

D2

D1||

D0

Hex

L

D2

D1||

D0

Hex

L

D2

D0

D1

Hex

15SHINSAEGI MEDI-TECH

Cement Retained Restoration : Cemented Abutment, Angled Abutment, UCLA Gold Abutment, UCLA Plastic Abutment,Temporary Abutment

Fixture(EST)

(Hex) (Non Hex)Fixture Impression Coping (Pick-up)

(Hex) (Non Hex)Fixture Impression Coping (Transfer)

Fixture Lab Analog(Narrow) (Regular) (Wide)

(Hex) (Non Hex)Cemented Abutment

ALIPS Driver ALIPS Screw Abutment Screw 1.2Hex Torque Driver

Angled Abutment (Hex) (Non Hex)UCLA Gold Abutment

(Hex) (Non Hex)UCLA Plastic Abutment

(Hex) (Non Hex)UCLA Temporary Abutment

0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

Prosthetic Flow Diagrams For EST System

69p

17p 18p

18p

20p

67p 67p

16p16p

14p

16p

20p

19p19p 19p

18p

18p

68p

16 SHINSAEGI MEDI-TECH

3.5 (Narrow)

1.5ESVN350ESVR410ESVW510

4.1 (Regular)

5.1 (Wide)

EST System

- Head height : 1.5mm- Instrumentation required 0.9hex hand driver- Torque recommendation : 5˜8Ncm

01Unit : mm

Fixture Platform Head Height (H) Code

3.5 (Narrow) ESHN350ESHR410ESHW510

4.1 (Regular)

5.1 (Wide)

- Instrumentation required 0.9hex hand driver- Torque recommendation : 5˜8Ncm Unit : mm

Fixture Platform Code

3.5(Narrow) EHAN402 EHAN403 EHAN404 EHAN405 EHAN407

EHAR507EHAR607EHAW607EHAW707EHAW807THAW507THAW607THSW607THSW707

EHAR505EHAR605EHAW605EHAW705EHAW805THAW505THAW605THSW605THSW705

EHAR504EHAR604EHAW604EHAW704EHAW804THAW504THAW604THSW604THSW704

EHAR503EHAR603EHAW603EHAW703EHAW803THAW503THAW603THSW603THSW703

EHAR502EHAR602EHAW602EHAW702EHAW802THAW502THAW602THSW602THSW702

4.0

5.06.06.07.08.05.05.66.06.8

4.1(Regular)

5.1(Wide)

5.0(Wide)T-Type

6.0(Wide)T-Type

- Select the height according to the gingival height (2, 3, 4, 5.5, 7mm)- Healing size marked for easy identification (Emergence profile, Restorative, Height)

- Instrumentation required 1.2hex hand driver- Torque recommendation : 5˜8Ncm

Healing Abutment

Unit : mm

FixturePlatform

Diam-eter(D)

G/H

2 3 4 5.5 7

1.5

G/H

D

Cover Screw

Headless Cover Screw

17SHINSAEGI MEDI-TECH

EST System

02

3.5 (Narrow) M 1.6Ti

Gold

Ti

Gold

Ti

Gold

Hex

Hex

Hex

Hex

Hex

Hex

M 2.0

M 2.5

ESATN35ESAGN35ESATR41ESAGR41ESATW51ESAGW51

4.1 (Regular)

5.1 (Wide)

Unit : mm

Fixture Platform Thread (T) Ti/Gold Type Code

3.5(Narrow)

EACN418H

EACN418N

EACR518H

EACR518N

EACR618H

EACR618N

EACW618H

EACW618N

EACW718H

EACW718N

EACW818H

EACW818N

EACN428H

EACN428N

EACR528H

EACR528N

EACR628H

EACR628N

EACW628H

EACW628N

EACW728H

EACW728N

EACW828H

EACW828N

EACN438H

EACN438N

EACR538H

EACR538N

EACR638H

EACR638N

EACW638H

EACW638N

EACW738H

EACW738N

EACW838H

EACW838N

EACN448H

EACN448N

EACR548H

EACR548N

EACR648H

EACR648N

EACW648H

EACW648N

EACW748H

EACW748N

EACW848H

EACW848N

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

888888888888

4.0

5.0

6.0

6.0

7.0

8.0

4.1(Regular)

5.1(Wide)

- Cemented retained restorations- Height is 8mm with marked groove 6mm and 7mm for easy cutting- Collar height : 1, 2 ,3, 4mm- Packing unit : Included abutment screw

(EACN Series + ESATN35, EACRSeries+ESATR41, EACW Series + ESATW51)- Torque recommendation : 30Ncm

Cemented Abutment

Unit : mm

FixturePlatform

Diameter(D)

G/H

4321

Height(H)

Type

3.4(Narrow)

TACN417H

TACN417N

TACR517H

TACR517N

TACR617H

TACR617N

TACW517H

TACW517N

TACW617H

TACW617N

TACS617H

TACS617N

TACN427H

TACN427N

TACR527H

TACR527N

TACR627H

TACR627N

TACW527H

TACW527N

TACW627H

TACW627N

TACS627H

TACS627N

TACN437H

TACN437N

TACR537H

TACR537N

TACR637H

TACR637N

TACW537H

TACW537N

TACW637H

TACW637N

TACS637H

TACS637N

TACN447H

TACN447N

TACR547H

TACR547N

TACR647H

TACR647N

TACW547H

TACW547N

TACW647H

TACW647N

TACS647H

TACS647N

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

777777777777

3.8

5.0

6.0

5.5

6.0

6.0

4.1(Regular)

5.0(Wide)

6.0

- Cement retained restoration - Combined T-type cemented abutment- Height is fixed 7mm- Packing unit : Included abutment screw(TACN, TACR, TACW Series +ESATR41 or ESAGR41)- Torque recommendation : 30Ncm

Cemented Abutment T-Type

Unit : mm

FixturePlatform

Diameter(D)

G/H

4321

Height(H)

Type

- Instrumentation required 1.2hex Torque driver- For use Cemented Abutment, T-Type Cemented Abutment & Temporary Abutment, UCLA Gold Abutment, UCLA Plastic Abutment

Cemented Abutment Screw

Gold Ti

Gold Ti

Gold Ti

8(H)

D

G/H

76

Hex

7(H)

G/H

Non-Hex

D

Hex

Non-Hex

18 SHINSAEGI MEDI-TECH

EST System

- Cement retained restorations- Angulation : 15 , 25- Collar height : 2mm, 4mm- Packing unit : Included abutment screw(EAAN Series + ESAAN35, EAAR Series + ESAAR41,

EAAW Series + ESAAW51, TAAW Series + ESAAR41) - Torque recommendation : 30Ncm

Angled Abutment03

3.5 (Narrow) 4.0

5.0

6.0

6.0

6.0

2424242424

EAAN4215EAAN4415EAAR5215EAAR5415EAAR6215EAAR6415EAAW6215EAAW6415TAAW6215TAAW6415

EAAN4225EAAN4425EAAR5225EAAR5425EAAR6225EAAR6425EAAW6225EAAW6425TAAW6225TAAW6425

4.1 (Regular)

5.1 (Wide)

5.0(Wide) T-Type

Unit : mm

Fixture PlatformDiameter

(D)G/H

Angel

15 25

Unit : mm

- For use cemented abutment- ALIPS(Anti Lock Inner Post Screw)- Instrumentation required ALIPS driver

3.44.15.0

M 2.0Ti

Gold

Hex

Hex

ESATR41

ESAGR41

Unit : mm

Fixture Platform Thread (T) Ti/Gold Type Code

Cemented Abutment Screw (T-Type)

3.5 (Narrow) M 1.6M 2.0M 2.5

ESAP001ESAP002ESAP003

4.1 (Regular)

5.1 (Wide)

Fixture Platform Thread (T) Code

Unit : mmFixture Lab Analog(UCLA)

3.5 (Narrow) Hex

Hex

Hex

Hex

Hex

ELUN350ELUR410ELUW510TLUW500TLUS600

4.1 (Regular)

5.1 (Wide)

5.0(Wide) T-Type

6.0 (Wide) T-Type

Fixture Platform Type Code

Gold Ti

7

D

G/H

ALIPS Locking Abutment Screw

19SHINSAEGI MEDI-TECH

3.5 (Narrow) ESAAN35ESAAR41ESAAW51

4.1 (Regular)

5.1 (Wide)

04

05

- Screw retained restoration - Gold alloy- Packing unit : Included abutment screw - Torque recommendation : 30Ncm

UCLA Gold Abutment

- Instrumentation required 1.2hex Torque driverAngled Abutment ScrewUnit : mm

Fixture Platform Code

3.5 (Narrow) 4.0

4.5

5.5

5.5

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

EAGN00H

EAGN00N

EAGR00H

EAGR00N

EAGW00H

EAGW00N

TAGW00H

TAGW00N

4.1 (Regular)

5.1 (Wide)

5.0(Wide) T-Type

Unit : mm

Fixture Platform Diameter (D) Type Code

3.5 (Narrow) 4.0

4.5

5.5

5.5

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

EAPN00H

EAPN00N

EAPR00H

EAPR00N

EAPW00H

EAPW00N

TAPW00H

TAPW00N

4.1 (Regular)

5.1 (Wide)

5.0(Wide) T-Type

Unit : mm

Fixture Platform Diameter (D) Type Code

3.5 (Narrow) 4.0

4.5

5.5

5.5

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

ETUN40H

ETUN40N

ETUR50H

ETUR50N

ETUW60H

ETUW60N

TTUW60H

TTUW60N

4.1 (Regular)

5.1 (Wide)

5.0(Wide) T-Type

Unit : mm

Fixture Platform Diameter (D) Type Code

EST System

- Screw retained restoration - Packing unit : Included Abutment Screw- Torque recommendation : 30Ncm

UCLA Plastic Abutment

06 - Temporary restoration- Packing unit : Included abutment screw (ETUN Series+ ESATN35, ETURSeries + ESATR41, ETUWSeries + ESATW51, TTUW Series + ESATR41)

- Torque recommendation : 15Ncm

UCLA Temporary Abutment

Gold Ti

Ti

Ti

D

Hex Non-Hex

D

Hex Non-Hex

D

Hex Non-Hex

20 SHINSAEGI MEDI-TECH

EST System

- Instrument required 1.2hex driverGuide Pin(Pick-up)

- Hex type(Two-piece)- Non hex type(One-piece, Two-piece)

Impression Coping(Transfer)

Narrow 15151715

ESGPN150ESGPR150ESGPR170ESGPW150

Regular

Wide

Unit : mm

Fixture Platform Height (H) Code

Guide Pin(Transfer)

3.5 (Narrow) ESGTN35ESGTR41ESGTW51

4.1 (Regular)

5.1 (Wide)

Unit : mm

Fixture Platform Code

- Length : 12mm- Packing unit : Included guide pin

Impression Coping(Pick-up)07

3.5 (Narrow) 4.0

5.0

6.0

6.0

5.5

6.0

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

EIPN40H

EIPN40N

EIPR50H

EIPR50N

EIPR60H

EIPR60N

EIPW60H

EIPW60N

TIPW55H

TIPW55N

TIPW60H

TIPW60N

4.1 (Regular)

5.1 (Wide)

5.0(Wide) T-Type

Unit : mm

Fixture Platform Diameter (D) Type Code

3.5 (Narrow) 4.5

5.0

6.0

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

EITN45H

EITN45N

EITR50H

EITR50N

EITW60H

EITW60N

4.1 (Regular)

5.1 (Wide)

Unit : mm

Fixture Platform Diameter (D) Type Code

H

D

Hex Non-Hex

D

Hex Non-Hex

21SHINSAEGI MEDI-TECH

Prosthetic Flow Diagrams For EST System

ALIA EXternal LockingAbutment Screw

1.2Hex Torque Driver Repositioning Jig

Repositioning Jig

Impression Plastic Cap

EXternal YK Transfer Adapter & Screw (EST)

ALIA EXternal Locking Lab Analog(Upper) (Lower)

ALIA EXternal Locking Abutment(Hex)

Screw Retained restoration : Estheticone, Midicone, Widecone, T-Type Widecone Abutment, Locking Abutment.

Fixture(EST)

Conical Abutment(Estheticone, Midicone,

Widecone, Widecone T-Type)

Conical Abutment Screw

Conical Healing Cap

Fixture Lab Analog

Conical Impression Coping (Pick-up)

Conical Impression Coping (Transfer)

0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

Conical Gold Cylinder Conical Plastic Cylinder Conical Temporary Cylinder

1.2Hex Torque Driver Cylinder Screw

14p

22p

22p

22p

23p 24p

24p

22p 23p 23p

22p

67p

16p16p

16p

67p

25p

25p

25p

25p

68p

69p

24p

69p

68p

22 SHINSAEGI MEDI-TECH

EST System

08 - Screw retained restoration - Collar height : 1, 2, 3, 4mm- Length : Estheticone 1.8mm, Widecone 1.0mm and Midicone 1.0mm- Instrumentation required Estheticone & Midicone 2.0hex driver,

Widecone 2.7hex driver- Packing unit : Included abutment screw(EAE Series + ESE001, EAM Series + ESM001, EAW Series + ESW001, TAW501 Series + TSW001, TAW Series + TSW002)

- Torque recommendation : 30Ncm

Conical Abutment

Estheticone EAE404EAM404EAW504TAW504TAW604

Midicone

Widecone

WideconeT-Type

Estheticone

Midicone

Widecone

WideconeT-Type

Unit : mm

FixturePlatform

Diameter(D)

Height(H)

G/H

4

EAE403EAM403EAW503TAW503TAW603

3

EAE402EAM402EAW502TAW502TAW602

2

EAE401EAM401EAW501TAW501TAW601

1.81.01.01.01.3

4.84.85.55.06.5

1

Conical Abutment Screw

2.02.02.72.02.0

ESE001ESM001ESW001TSW001TSW002

Unit : mm

Fixture Platform Hex Code

Estheticone

Midicone

Widecone

WideconeT-Type

5.55.56.25.06.5

ECE001ECM001ECW001TCW001TCW002

Unit : mm

Fixture Platform Diameter (D) Code

- Instrumentation required 1.2hex driver- Torque recommendation : 20Ncm

- Instrumentation required 1.2hex Torque driver

Conical Healing Cap

- Gold alloy- Packing unit : Included cylinder screw(Estheticone + ESYTE41(ESYGE41), Midicone + ESYTM41(ESYGM41), Widecone + ESYTW51(ESYGW51), Widecone(T) +TSYIW50(TSYGW50))

- Torque recommendation : 20Ncm

Conical Gold Cylinder

Estheticone 4.8

4.8

5.5

5.5

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

EAGE00H

EAGE00N

EAGM00H

EAGM00N

EAGW00H

EAGW00N

TAGW00H

TAGW00N

Midicone

Widecone

WideconeT-Type

Unit : mm

Fixture Platform Diameter (D) Type Code

Gold Ti

H

D

G/H

H

D

D

Hex Non-Hex

23SHINSAEGI MEDI-TECH

Estheticone(Regular)

Midicone(Regular)

Widecone(Wide)

Widecone(Wide) T-Type

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

EIPE00H

EIPE00N

EIPM00H

EIPM00N

EIPW00H

EIPW00N

TIPW00H

TIPW00N

Unit : mm

Fixture Platform Type Product

Estheticone

Midicone

Widecone

WideconeT-Type

Ti

Gold

Ti

Gold

Ti

Gold

Ti

Gold

ESYTE41ESYGE41ESYTM41ESYGM41ESYTW51ESYGW51TSYTW50TSYGW50

Unit : mm

Fixture Platform Type Product

- Packing unit : Included cylinder screw(Estheticone + ESYTE41, Midicone + ESYTM41, Widecone + ESTW51, Widecone(T) + TSYTW50)

- Torque recommendation : 20Ncm

Conical Plastic Cylinder

- Screw retained restoration- Packing unit : Included cylinder screw(Estheticone + ESYTE41, Midicone + ESYTM41, Widecone + ESYTW51, Widecone(T) + TSYTW50)

- Torque recommendation : 20Ncm

Conical Temporary Cylinder

- Instrumentation required 1.2hex Torque driverConical Cylinder Screw

- Packing unit : Included guide pinConical Impression Coping(pick-up)

EST System

Estheticone 4.8

4.8

5.5

5.5

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

EAPE00H

EAPE00N

EAPM00H

EAPM00N

EAPW00H

EAPW00N

TAPW00H

TAPW00N

Midicone

Widecone

WideconeT-Type

Unit : mm

Fixture Platform Diameter (D) Type Code

Estheticone 4.8

5.3

6.0

6.0

6.5

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

ETE001H

ETE001N

ETM001H

ETM001N

ETW001H

ETW001N

TTW001H

TTW001N

TTW002H

TTW002N

Midicone

Widecone

WideconeT-Type

Unit : mm

Fixture Platform Diameter (D) Type Code

Gold Ti

Ti

Ti

D

Hex Non-Hex

D

Hex

Hex

Non-Hex

Non-Hex

24 SHINSAEGI MEDI-TECH

EST System

Estheticone

Midicone

Widecone

WideconeT-Type

813158

13158

13158

1315

ESGE080ESGE130ESGE150ESGM080ESGM130ESGM150ESGW080ESGW130ESGW150TSGW080TSGW130TSGW150

Unit : mm

Fixture Platform Height (H) Product

- Instrument required 1.2hex driverConical Guide Pin(pick-up)

Conical Impression Coping (Transfer)

4.1 (Regular) Estheticone

Midicone

Widecone

Widecone

EITE00N

EITM00N

EITW00N

TITW00N

4.1 (Regular)

5.1 (Wide)

5.0 (Wide) T-Type

Unit : mm

Fixture Platform Type Product

Conical Lab Analog

4.1 (Regular) Estheticone

Midicone

Widecone

Widecone

Widecone

ELEH410ELEL410ELEL510TLEL500TLEL600

4.1 (Regular)

5.1 (Wide)

5.0 (Wide) T-Type

6.0 (Wide) T-Type

Unit : mm

Fixture Platform Type Product

- Screw retained restoration - Hexagon base for anti-rotating locking with a locking abutment screw- Packing unit : Included abutment screw(EALN Series + ESLN Series, EALR Series + ESLR Series, EALW Series +

ESLW Series) ex) EALN401H + ESLN401

- Torque recommendation : 30Ncm

ALIA External Locking Abutment (Hex)09

3.5 (Narrow) EALN404H

EALR504H

EALR604H

EALW604H

EALW704H

EALW804H

TALW604H

TALW704H

TALS604H

TALS704H

4.1 (Regular)

5.1 (Wide)

5.0 (Wide)

6.0 (Wide)

Unit : mm

FixturePlatform

Diameter(D)

Hex(H)

G/H

4

EALN403H

EALR503H

EALR603H

EALW603H

EALW703H

EALW803H

TALW603H

TALW703H

TALS603H

TALS703H

3

EALN402H

EALR502H

EALR602H

EALW602H

EALW702H

EALW802H

TALW602H

TALW702H

TALS602H

TALS702H

2

EALN401H

EALR501H

EALR601H

EALW601H

EALW701H

EALW801H

TALW601H

TALW701H

TALS601H

TALS701H

2.42.72.73.43.43.42.72.72.72.7

4.05.06.06.07.08.06.07.06.07.0

1

H

G/H

Hex

D

25SHINSAEGI MEDI-TECH

3.5 (Narrow) ESLN401ESLR501ESLR601ESLW601ESLW701ESLW801TSLW601TSLW701

ESLN402ESLR502ESLR602ESLW602ESLW702ESLW802TSLW602TSLW702

ESLN403ESLR503ESLR603ESLW603ESLW703ESLW803TSLW603TSLW703

ESLN404ESLR504ESLR604ESLW604ESLW704ESLW804TSLW604TSLW704

4.1 (Regular)

5.1 (Wide)

5.0 (Wide)

3.5 4.0

5.0

6.0

6.0

2.4

2.7

3.4

2.7

1.53.51.53.51.53.51.53.5

4.1

5.1

5.0

3.5

4.1

5.1

5.0

Unit : mm

Fixture PlatformLength(L)

8 9 10 11

- Instrument required 1.2hex Torque driver or Positioning JigExternal Locking Abutment Screw

EST System

ETLN150ETLN350ETLR150ETLR350ETLW150ETLW350TTLW150TTLW350

Unit : mm

Fixture Platform Diameter (D) Hex G/H Code

3.36

3.86

4.86

4.86

9119

119

119

11

ESTLN35S

ESTLN35L

ESTLR41S

ESTLR41L

ESTLW51S

ESTLW51L

TSTLW50S

TSTLW50L

Unit : mm

Fixture Platform Diameter (D) Length (L) Code

- Packing unit : Included External YK Transfer screw- Torque recommendation : 15Ncm

External YK Transfer Adapter

- Instrument required 1.2hex Torque driver or Positioning JigExternal YK Transfer Screw

3.5

4.1

5.1

5.0T-Type

6.0T-Type

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

Upper

Lower

ELLN001ELLN002ELLR001ELLR002ELLW001ELLW002TLLW001TLLW002TLLS001TLLS002

Unit : mm

Fixture Platform Type Code

- Packing unit : Included Upper+LowerExternal Locking Lab Analog

L

L

G/H

Hex

D

(Upper) (Lower)

Impression Plastic CapSIYC 600

Unit : mm

Code

26 SHINSAEGI MEDI-TECH

Prosthetic Flow Diagrams For EST System

Overdenture Retained Restoration for O-Ring Abutment

Fixture(EST)

0.9Hex Hand Driver Cover Screw Headless Cover Screw Healing Abutment

O-Ring Abutment

O-Ring Lab Analog

O-Ring Retainer

For Denture O-Ring(Red)

For laboratory O-Ring(Black)

O-Ring Abutment Driver(2.4 Hex)

1.2Hex Hand Driver

67p 67p

16p16p

27p

27p

27p

27p27p

68p

14p

16p

27SHINSAEGI MEDI-TECH

EARR200 EARR300 EARR400 EARR500 EARR6005.04.1(Regular)

- Overdenture restoration- Multiple implant bone retained and fixed removable overdentures- Seating surface diameter 4.1mm- Collar height : 2, 3, 4, 5, 6mm- Instrument required O-Ring Abutment Driver(2.4hex) - Packing unit : Included O-Ring 2ea and O-Ring Retainer 1ea

- Female receptacle processed into denture

Unit : mm

FixturePlatform

Diam-eter(D)

G/H

2.0 3.0 4.0 5.0 6.0

O-Ring Abutment

O-Ring

EST System

10

Red(Denture)

Black(Laboratory)

IARR002IARR003

Unit : mm

Type Code

O-Ring Retainer

IARR001

Unit : mm

Code

O-Ring Lab AnalogRL001

Unit : mm

Code

G/H

D

28 SHINSAEGI MEDI-TECH

29SHINSAEGI MEDI-TECH

Submerged

FixtureEsthetic & Innovation

SHINSAEGI MEDI-TECH

30 SHINSAEGI MEDI-TECH

SST System

Sub-Cover ScrewSub-Healing AbutmentSub-Solid AbutmentSub-Solid Impression CopingSub-Solid plastic CopingSub-Solid Healing CapSub-Solid Lab AnalogSub-Cemented AbutmentSub-Cemented Abutment ScrewALIPS Locking Abutment ScrewSub-Angled AbutmentSub-Temporary AbutmentSub-Impression Coping (Pick-up)Sub-Impression Coping Guide Pin (Pick-up)Sub-Impression Coping Guide Pin (Transfer)Sub-Impression Coping (Transfer)Sub-Gold AbutmentSub-Fixture Lab AnalogALIA Sub-Locking Abutment (Hex)Sub-Locking Abutment ScrewSub-YK Transfer AdapterSub-YK Transfer ScrewSub-Locking Fixture Lab AnalogSub-O-Ring AbutmentSub-O-RingSub-RetainerSub-O-Ring Lab Analog

34p34p34p35p35p35p35p37p37p37p37p37p38p38p38p38p38p38p40p40p40p40p40p42p42p42p42p

01

02

03

0405

06

07

31SHINSAEGI MEDI-TECH

SU

BM

ER

GE

D (S

ST

)IN

TE

RN

AL

(IST

.IT)

INT

ER

NA

L (IS

T.IT

)E

XT

ER

NA

L (

ES

T)

Submerged Slightly Tapered Fixture (SST System)- SST implant components and ASTRA implant components are fully interchangeable.

The inner of head

Internal Hex connection

Micro groove

- Acheive both soft and hard tissue attachement

- Generate strong attachment of cortical bone

- Superior primary stability

Apex

Sharp tip on 3-cutting edge-This sharp tip also secures a smooth insertion without the implant wobbling

-Implant will not spin and loss stablity when a higher density area in reached

-This thread design make the implant a very efficient selftapping unit.

Body of head

Flapless surgery- Head design is the same diameter as the implant body

- This implant ideal for surgeryNo counter sinking- This makes the surgical

procedure faster and simple.

Body design

Slightly taper-This design for increased initial stablity in soft bone

Unique grooves-Increase stability compared to "v"type thread implant

32 SHINSAEGI MEDI-TECH

Submerged Slightly Tapered Fixture (SST System)

- Submerged Internal Hex connection- Hex : 2.5mm- Apex size : Narrow( 2.25mm), Regular( 2.9mm), Wide( 3.6mm), Wide6.0( 4.3mm)- Torque recommendation : 40Ncm

Unit : mm

Feature

Narrow SST SystemPlatform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Hex(H)

Length(L)

Code

SFSN309

SFSN311

SFSN313

SFSN315

9

11

13

15

2.53.753.83.8

Unit : mmWide6.0 SST SystemPlatform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Hex(H)

Length(L)

Code

SFSW607

SFSW609

SFSW611

SFSW613

7

9

11

13

2.55.96.05.0

Unit : mmRegular SST SystemPlatform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Hex(H)

Length(L)

Code

SFSR407

SFSR409

SFSR411

SFSR413

SFSR415

7

9

11

13

15

2.54.24.34.3

Unit : mmWide SST SystemPlatform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Hex(H)

Length(L)

Code

SFSW507

SFSW509

SFSW511

SFSW513

SFSW515

7

9

11

13

15

2.54.95.05.0

L

D2

D1||

D0

Hex

L

D2

D1||

D0

Hex

L

D2

D1||

D0

Hex

L

D2

D0

D1

Hex

33SHINSAEGI MEDI-TECH

Cement Retained restoration for Sub-Solid Abutment

Fixture(SST)

Sub-Cover Screw Sub-Healing Abutment

1.2Hex Torque Driver Sub-Solid Abutment( 4.5, 5.5, 6.5)

Sub-Solid Healing Cap

Sub-Solid Impression Coping

Sub-Solid Lab Analog

(Single) (Bridge)Sub-Solid Plastic Coping

1.2Hex Hand Driver

Prosthetic Flow Diagrams For SST System

68p

35p

34p

34p 34p

67p

34p

35p

35p

32p

34 SHINSAEGI MEDI-TECH

3.80.5

1.5

SSV001

SSV002

4.35.06.0

SST System

- Head height : 0.5, 1.5mm - Instrumentation required 1.2hex hand driver- Torque recommendation : 5˜8Ncm

Sub-Cover Screw01Unit : mm

Platform Diameter(D) Height (H) Code

- Cement retained restoration- Height is 5.5mm with marked groove 4mm for easy cutting - Collar height : 1.5, 2.5, 3.5, 4.5, 5.5mm and specially SASN series height

1.0, 1.5, 2.5, 3.5, 4.5mm- Profile diameter : 4.5, 5.5, 6.5mm- Instrument required 1.2hex driver- Torque recommendation : 30Ncm

Sub-Solid Abutment02

3.8(Narrow)

4.3(Regular)

5.06.0

(Wide)

- Instrumentation required 1.2hex driver- Torque recommendation : 5˜8Ncm

Sub-Healing AbutmentUnit : mm

FixturePlatform

Diam-eter(D) 1.5

4.5 SHAN4515

-SHAR5515SHAW6515SHAW7515

2.0

-

SHAR5020---

2.5

SHAN4525

-SHAR5525SHAW6525SHAW7525

3.0

-

SHAR5030---

3.5

SHAN4535

-SHAR5535SHAW6535SHAW7535

4.5

SHAN4545

-SHAR5545SHAW6545SHAW7545

5.0

-

SHAR5050---

5.5

SHAN4555

-SHAR5555SHAW6555SHAW7555

5.05.56.57.5

Code

3.8(Narrow)

4.3(Regular)

5.06.0

(Wide)

Unit : mm

FixturePlatform

Diam-eter(D) 5.54.53.52.51.51.0

4.5

5.5

6.5

-

SASR5555

SASW6555

SASN4545

SASR5545

SASW6545

SASN4535

SASR5535

SASW6535

SASN4525

SASR5525

SASW6525

SASN4515

SASR5515

SASW6515

SASN4510

-

-

Code

G/H2

D

5.5

G/H

4

D

4.5

5.5

6.5

4.5

5.5

6.5

4.55.56.5

4.55.56.5

35SHINSAEGI MEDI-TECH

SST System

Sub-Solid Impression Coping

SISC45L

SISC55L

SISC65L

Unit : mm

Diameter (D) Code

SHS45L

SHS55L

SHS65L

Unit : mm

Diameter (D) Code

Sub-Solid plastic Coping

Single

Bridge

Single

Bridge

Single

Bridge

SISP45S

SISP45B

SISP55S

SISP55B

SISP65S

SISP65B

Unit : mm

Diameter (D) Type Code

4.05.54.05.54.05.5

SLSN45S

SLSN45L

SLSR55S

SLSR55L

SLSW65S

SLSW65L

Unit : mm

Diameter (D) Height (H) Code

Sub-Solid Healing Cap

D

Single Bridge

Short Long

Sub-Solid Lab Analog

H

36 SHINSAEGI MEDI-TECH

Prosthetic Flow Diagrams For SST System

Screw & Cement Retained restoration for Sub-Cement Abutment, Sub-Angled Abutment, Sub-TemporaryAbutment, Sub-Gold Abutment

Fixture(SST)

Sub-Cover Screw Sub-Healing Abutment

(Hex) (Non Hex)Sub-Impression Coping (Pick-up)

Sub-Fixture Lab Analog

(Hex) (Non Hex)Sub-Angled Abutment

(Hex) (Non Hex)Sub-Temporary Abutment

(Hex) (Non Hex)Sub-Gold Abutment

(Hex) (Non Hex)Sub-Cemented Abutment

Sub-Abutment Screw 1.2Hex Torque DriverALIPS Locking ScrewALIPS Driver

(Hex) (Non Hex)Sub-Impression Coping (Transfer)

1.2Hex Hand Driver

32p

69p 37p

37p 37p

38p

38p 38p

34p34p

67p

37p 38p

37p

68p

3.84.35.06.0

37SHINSAEGI MEDI-TECH

- For use In-octa cemented abutment - ALIPS(Anti Lock Inner Post Screw)- Instrumentation required ALIPS driver

ALIPS Locking Abutment Screw

Sub-Cemented Abutment Screw

SST System

SSA001

Unit : mm

Code

ISAP001

Unit : mm

Diameter (D) Code

- Instrumentation required 1.2hex Torque driver

- Cement retained restoration - Collar height : 1.5, 2.5, 3.5, 4.5, 5.5mm- Specially SACN series height : 1.0, 2.5, 3.5, 4.5mm- Packing unit : Included abutment screw(SSA001)- Profile diameter : 4.5, 5.5, 6.5mm- Length is 7mm with marked microgroove 4.0mm and 5.5mm for easy cutting- Torque recommendation : 30Ncm

Sub-Cemented Abutment03

3.8(Narrow)

4.3(Regular)

6.0 (Wide)

5.0(Wide)

Unit : mm

FixturePlatform

Diam-eter(D)

Length(L)

Type5.54.53.52.51.51.0

4.55.5

7.0

5.5

7.0

5.5

7.0

5.5

6.5

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

-

-

-

-

SAC5555H

SAC5555N

SACR5555H

SACR5555N

SAC6555H

SAC6555N

SACW6555H

SACW6555N

SAC4545H

SAC4545N

SACN4545H

SACN4545N

SAC5545H

SAC5545N

SACR5545H

SACR5545N

SAC6545H

SAC6545N

SACW6545H

SACW6545N

SAC4535H

SAC4535N

SACN4535H

SACN4535N

SAC5535H

SAC5535N

SACR5535H

SACR5535N

SAC6535H

SAC6535N

SACW6535H

SACW6535N

SAC4525H

SAC4525N

SACN4525H

SACN4525N

SAC5525H

SAC5525N

SACR5525H

SACR5525N

SAC6525H

SAC6525N

SACW6525H

SACW6525N

SAC4515H

SAC4515N

SACN4515H

SACN4515N

SAC5515H

SAC5515N

SACR5515H

SACR5515N

SAC6515H

SAC6515N

SACW6515H

SACW6515N

SAC4510H

SAC4510N

SACN4510H

SACN4510N

-

-

-

-

-

-

-

-

G/H

4 5.5 7 L

G/H

D

Hex Non-Hex

Hex Non-Hex

3.8 (Narrow)

4.3 (Regular)

Unit : mm

FixturePlatform

Diameter(D)

Angle( )

G/H

2.0 4.0

4.5

5.5

15251525

SAAN4152H (N)

SAAN4252H (N)

SAAR5152H (N)

SAAR5252H (N)

SAAN4154H (N)

SAAN4254H (N)

SAAR5154H (N)

SAAR5254H (N)

- Cement retained restorations - Angulation : 15 , 25- Collar height : 2mm, 4mm - Packing unit : Included abutment screw (SSA001)

Sub-Angled Abutment04

1.0

3.0

Hex

Non-Hex

Hex

Non-Hex

STAN4510H

STAN4510N

STAN4530H

STAN4530N

- Packing unit : Included Abutment Screw(SSA001)- Torque recommendation : 30Ncm

Sub-Temporary Abutment05Unit : mm

G/H Type 4.5

7

G/H

D

D

Hex Non-Hex

G/H

4.5

5.5

6.5

4.5

5.5

6.5

38 SHINSAEGI MEDI-TECH

SST System

Sub-Impression Coping Guide Pin (Transfer)

Short

Long

SSGT00S

SSGT00L

Unit : mm

Height (H) Code

Sub-Fixture Lab Analog

SLFR001

Unit : mm

Code

1.0

3.0

Hex

Non-Hex

Hex

Non-Hex

SAGN4510H

SAGN4510N

SAGN4530H

SAGN4530N

SAGN5510H

SAGN5510N

SAGN5530H

SAGN5530N

SAGN6510H

SAGN6510N

SAGN6530H

SAGN6530N

- Packing unit : Included Abutment Screw(SSA001)- Torque recommendation : 30Ncm

Sub-Gold AbutmentUnit : mm

G/H Type 4.5 5.5 6.5

G/H

D

Hex Non-Hex

Sub-Impression Coping Guide Pin (Pick-up)

Short

Long

SSGP00S

SSGP00L

Unit : mm

Height (H) Code

- Packing unit : Included Guide PinSub-Impression Coping (Pick-up)

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Short14Long18Short14Long18Short14Long18Short14Long18Short14Long18Short14Long18

SIPN45HS

SIPN45HL

SIPN45NS

SIPN45NL

SIPR55HS

SIPR55HL

SIPR55NS

SIPR55NL

SIPW65HS

SIPW65HL

SIPW65NS

SIPW65NL

Unit : mm

Fixture Platform Diameter (D) Length (L) Code

H

D

Sub-Impression Coping (Transfer)

Hex

Non-Hex

Hex

Non-Hex

Hex

Non-Hex

Short10Long14Short10Long14Short10Long14Short10Long14Short10Long14Short10Long14

SITN45HS

SITN45HL

SITN45NS

SITN45NL

SITR55HS

SITR55HL

SITR55NS

SITR55NL

SITW65HS

SITW65HL

SITW65NS

SITW65NL

Unit : mm

Fixture Platform Diameter (D) Length (L) Code

Hex Non-Hex

D

Hex Non-Hex

L

39SHINSAEGI MEDI-TECH

Cement & Screw Retained Restoration Component for Sub-Locking Abutment, Sub-Locking Temporary Abutment

Prosthetic Flow Diagrams For SST System

Sub-YK Transfer Adapter & Screw (SST)

Impression Plastic Cap

Repositioning Jig

ALIA Sub-Locking Lab Analog(Upper) (Lower)

ALIA Sub-Locking Abutment Screw Repositioning Jig

ALIA Sub-Locking Abutment

1.2Hex Torque Driver

Fixture(SST)

Sub-Cover Screw Sub-Healing Abutment 1.2Hex Hand Driver

32p

40p

40p

40p

40p

69p

34p34p

67p

68p40p

69p

40 SHINSAEGI MEDI-TECH

SST System

- Screw retained restoration - Hexagon base for anti-rotating locking with a locking abutment screw- Packing unit : Included abutment screw(SALN Series + SSLN Series, SALR Series + SSLR Series, SALW Series + SSLW Series)

- Torque required 30Ncm

ALIA Sub-Locking Abutment (Hex)06

3.8 (Narrow)

4.3 (Regular)

5.0 (Wide)

6.0 (Wide)

Unit : mm

FixturePlatform

Diameter(D)

G/H

SALN4510H

-

-

4.55.5

6.5

1

SALN4515H

SALR5515H

SALW6515H

1.5

SALN4525H

SALR5525H

SALW6525H

2.5

SALN4535H

SALR5535H

SALW6535H

3.5

SALN4545H

SALR5545H

SALW6545H

4.5

- Instrumentation required 1.2Hex Torque driver or reposintiong JigSub-Locking Abutment Screw

Sub-YK Transfer Adapter

3.8 (Narrow)

4.3 (Regular)

5.0 (Wide)

6.0 (Wide)

Unit : mm

FixturePlatform

Length(L)

SSLN4510-

-

8

SSLN4515SSLR5515

SSLW6515

9

SSLN4525SSLR5525

SSLW6525

10

SSLN4535SSLR5535

SSLW6535

11

SSLN4545SSLR5545

SSLW6545

12

1.53.5

STAL150STAL350

Unit : mm

G/H Code

Upper

Lower

SLLR001SLLR002

Unit : mm

Type Code

- Instrumentation required 1.2Hex driver or reposintiong JigSub-YK Transfer Adapter Screw

9

11SSTL090SSTL110

Unit : mm

Height(H) Code

G/H

D

G/H

L

H

Sub-Locking Fixture Lab Analog

(Upper) (Lower)

Impression Plastic CapSIYC 600

Unit : mm

Code

41SHINSAEGI MEDI-TECH

Overdenture Retained Restoration for O-Ring Abutment

Prosthetic Flow Diagrams For SST System

Fixture(SST)

Sub-Cover Screw Sub-Healing Abutment

O-Ring Abutment Driver(2.4Hex)

Sub-O-Ring Abutment

1.2Hex Hand Driver

Sub-O-Ring Lab Analog

Retainer

For Denture O-Ring For Laboratory O-Ring

32p

34p

42p

42p

42p

42p 42p

34p

67p

68p

42 SHINSAEGI MEDI-TECH

SST System

- Overdenture restoration - Multiple implant bone retained and fixed removable overdenture- Collar height : 1, 2, 3, 4mm- Instrument required : O-Ring abutment driver(2.4Hex) - Packing unit : Included O-Ring 2ea, Sub-retainer 1ea- Torque recommendation : 30Ncm

Sub-O-Ring Abutment07

4.55.5

Unit : mm

Diameter(D)

G/H

SARN4510SARR5510

SARN4520SARR5520

SARN4530SARR5530

SARN4540SARR5540

1.0 2.0 3.0 4.0

Sub-O-Ring

Red(Denture)Black(Laboratory)

IARR002IARR003

Unit : mm

Type Code

- Female receptacle processed into dentureSub-Retainer

IARR001

Unit : mm

Code

Sub-O-Ring Lab Analog

RL001

Unit : mm

Code

G/H

D

43SHINSAEGI MEDI-TECH

Internal

FixtureEsthetic & Innovation

SHINSAEGI MEDI-TECH

44 SHINSAEGI MEDI-TECH

SHINSAEGI MEDI-TECH 45

SU

BM

ER

GE

D (S

ST

)IN

TE

RN

AL

(IST

.IT)

INT

ER

NA

L (IS

T.IT

)E

XT

ER

NA

L (

ES

T)

Internal Slightly Tapered Fixture (IST System)- IST Implant components and ITI, SWISS PLUS IMPLANT components are fully interchaneable.

The inner of head

Internal octa connection

Micro groove under of head

Positive anchor asosseointegration occusAcheive both soft and hardtissue attachmentSuperior primary stability

Apex

Sharp tip on 3-cutting edge-This sharp tip also secures a smooth insertion without the implant wobbling

-Implant will not spin and loss stablity when a higher density area in reached

-This thread design make the implant a very efficient selftapping unit.

Body of head Esthetic collar

Machined finished collar of1.8mm

Body design

Slightly taper-This design for increased initial stablity in soft bone

Unique grooves-Increase stability compared to "v"type thread implant

46 SHINSAEGI MEDI-TECH

Internal Slightly Tapered Fixture (IST System)

- Internal octa connection- Collar height is fixed 1.8mm- Apex size : Regular( 2.4mm), Wide( 2.6mm), Wide6.0( 4.0mm)- Torque recommendation : 40Ncm

Feature

Unit : mm

Wide6.0 IST System

Platform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Octa(O)

Length(L)

Code

IFSW607

IFSW609

IFSW611

IFSW613

7

9

11

13

3.15.36.06.0

Unit : mm

Regular IST System

Platform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Octa(O)

Length(L)

Code

IFSR407

IFSR409

IFSR411

IFSR413

IFSR415

7

9

11

13

15

3.14.14.84.8

Unit : mm

Wide IST System

Platform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Octa(O)

Length(L)

Code

IFSW507

IFSW509

IFSW511

IFSW513

IFSW515

7

9

11

13

15

3.14.84.84.8

L

1.8 O

D1||

D0

L

1.8 O

L

1.8 O

D2

D1||

D0

D1||

D0

D2

47SHINSAEGI MEDI-TECH

Internal

FixtureEsthetic & Innovation

SHINSAEGI MEDI-TECH

IT & IST System

Cover ScrewHeadless Cover ScrewHealing AbutmentSolid AbutmentSolid Healing CapSolid Impression CopingSolid Positioning CylinderSolid Impression CapSolid Impression Shoulder AnalogSolid Impression Shoulder Analog PinSolid Plastic CopingSolid Lab AnalogExcellent Solid AbutmentExcellent Solid Healing CapExcellent Solid Impression CopingExcellent Solid Positioning CylinderExcellent Solid Impression CapExcellent Solid Impression Shoulder AnalogExcellent Solid Impression Shoulder Analog PinExcellent Solid Plastic CopingExcellent Solid Lab AnalogSolid Angled AbutmentSolid Angled Abutment ScrewIn-Octa Cemented AbutmentIn-Octa Cemented Abutment ScrewALIPS Locking Abutment ScrewIn-Octa Locking Abutment (Octa)In-Octa Locking Abutment ScrewIn-Octa YK Transfer AdapterIn-Octa YK Transfer Adapter ScrewIn-Octa Locking Lab AnalogIn-Octa Gold AbutmentIn-Octa Impression Coping (pick-up)In-Octa Guide Pin(pick-up)In-Octa Impression Coping (Transfer)In-Octa Guide Pin(Transfer)In-Octa Lab AnalogOcta AbutmentOcta Abutment Healing CapOcta Gold CylinderOcta Plastic CylinderOcta Abutment and Cylinder ScrewOcta Impression Coping (pick-up)Guide Pin (pick-up)Octa Lab AnalogO-Ring AbutmentO-RingO-Ring RetainerO-Ring Lab Analog

52p52p52p52p52p53p53p53p53p53p53p54p54p54p54p54p55p55p55p55p55p57p57p57p57p57p58p58p58p58p58p59p59p59p59p59p59p61p61p61p61p62p62p62p62p64p64p64p64p

01

02

03

04

05

06

07

48 SHINSAEGI MEDI-TECH

49SHINSAEGI MEDI-TECH

SU

BM

ER

GE

D (S

ST

)IN

TE

RN

AL

(IST

.IT)

INT

ER

NA

L (IS

T.IT

)E

XT

ER

NA

L (

ES

T)

Internal Tapered Fixture (IT System)- IT implant components and ITI, SWISS PLUS implant components are fully interchangeable.

The inner of head

Internal octa connection

Micro groove under of head

Positive anchor asosseointegration occusAcheive both soft and hardtissue attachmentSuperior primary stability

Apex

- This innovation design is a selftapping tapered implant that provides lateral compression of the osteotomy site to greatly improve primary stability

- This tapered design make the implant a very efficient selftapping unit

Body of head Esthetic collar

Machined finished collar of1.8mm

Body design

This design have a taperedshape similar to roots formrequining less bone removaland less bone augmentation totill the extraction socket

50 SHINSAEGI MEDI-TECH

Internal Tapered Fixture (IT System)

- Internal octa connection- Collar height is fixed 1.8mm- Apex size : Regular( 2.4mm), Wide( 3.1mm), Wide6.0( 3.6mm)- Torque recommendation : 40Ncm

Feature

Unit : mm

Platform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Octa(O)

Length(L)

Code

IFTW607

IFTW609

IFTW611

IFTW613

7

9

11

13

3.15.36.06.0

Unit : mm

Platform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Octa(O)

Length(L)

Code

IFTR407

IFTR409

IFTR411

IFTR413

IFTR415

7

9

11

13

15

3.14.14.84.8

Unit : mm

Platform Diameter

(D0)

Head Diameter

(D1)

Body Diameter

(D2)

Octa(O)

Length(L)

Code

IFTW507

IFTW509

IFTW511

IFTW513

IFTW515

7

9

11

13

15

3.14.84.84.8

Wide6.0 IT System

Regular IT System

Wide IT System

L

1.8 O

D1||

D0

D2

L

1.8 O

D1||

D0

D2

L

1.8 O

D1||

D0

D2

51SHINSAEGI MEDI-TECH

Cement Retained restoration for Solid Abutment, Excellent Solid Abutment

Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)

Cover Screw Headless Cover Screw Healing Abutment

Solid Healing CapExcellent Solid Healing Cap

Solid AbutmentExcellent Solid Abutment

Solid DriverExcellent Solid Driver

Solid Impression CapExcellent Solid Impression Cap

Solid shoulder AnalogExcellent Solid shoulder Analog

Solid shoulder Analog PinExcellent Solid shoulder Analog Pin

Solid Positioning CylinderExcellent Solid Positioning Cylinder

Solid Lab AnalogExcellent Solid Lab Analog

Single(Red) Bridge(White)Solid Plastic Coping

Excellent Solid Plastic Coping

1.2Hex Hand Driver

Prosthetic Flow Diagrams For IST And IT System

46p

52p

52p,54p

52p,54p

53p,55p

53p,55p 53p,55p

55p

53p, 55p

54p

53p,55p

68p

52p 52p

67p

50p

52 SHINSAEGI MEDI-TECH

IST & IT System

- Head height : 1.3mm- Instrumentation required 1.2Hex hand driver- Torque recommendation : 5˜8Ncm

Cover Screw01

02

4.86.0

ISV400ISV600

Unit : mm

Platform Diameter (mm) Code

- Instrumentation required 1.2Hex hand driver- Torque recommendation : 5˜8Ncm

Headless Cover Screw

4.86.0

ISH400

Unit : mm

Platform Diameter (mm) Code

- Profile diameter : 4.8, 5.5, 6.0, 7.0mm- Head height : 2, 3, 4mm- Instrumentation required 1.2hex hand driver- Torque recommendation : 5˜8Ncm

Healing Abutment

4.8

6.0

Unit : mm

PlatformDiameter(mm)

Diameter(D)

G/H

4.85.56.07.0

IHA420IHA520IHA620IHA720

IHA430IHA530IHA630IHA730

IHA440IHA540IHA640IHA740

2 3 4

- It is available in three heights to accommodate vertical requirements(4.0, 5.5, 7.0mm)

- For use in single tooth or multiple unit restoration- Packing unit : Included solid healing cap- Instrumentation required Solid driver- Torque recommendation : 30Ncm

Solid Abutment

4.8

Unit : mm

Platform Diameter(mm)Length (L)

IAS440 IAS455 IAS4704.0 5.5 7.0

- For use protect for solid abutmentSolid Healing Cap

45.57

IHSC440IHSC455IHSC470

Unit : mm

Height (H) Product

G/H

D

L

D

53SHINSAEGI MEDI-TECH

IST & IT System

4.86.0

IISC480IISC600

Unit : mm

Platform Code

4.86.0

IISL480IISL600

Unit : mm

Platform Code

4.86.0

IISN480IISN600

Unit : mm

Platform Code

Solid Positioning Cylinder

4.8

6.0

45.574

5.57

IISY440IISY455IISY470IISY640IISY655IISY670

Unit : mm

Platform Diameter(mm) Height (H) Code

Solid Impression Cap

- Solid positioning cylinder + Solid impression cap = Solid impression copingSolid Impression Coping

45.57

IISI440IISI455IISI470

Unit : mm

Height (H) Code

4.8

6.0

Single(Red)Bridge(White)

Single(Red)Bridge(White)

IISP48S

IISP48B

IISP60S

IISP60B

Unit : mm

Platform Diameter(mm) Color Code

Solid Impression Shoulder Analog

Solid Impression Shoulder Analog Pin

Solid Plastic Coping

D

54 SHINSAEGI MEDI-TECH

IST & IT System

- For use protect for excellent solid abutmentExcellent Solid Healing Cap

4.86.0

Unit : mm

Platform DiameterHeight (H)

IHXC440IHXC640

IHXC455IHXC655

IHXC470IHXC670

4.0 5.5 7.0

- Excellent Solid positioning cylinder + Solid impression cap = Solid impression copingExcellent Solid Impression Coping

4.86.0

Unit : mm

Platform DiameterHeight (H)

IIXI440IIXI640

IIXI455IIXI655

IIXI470IIXI670

4.0 5.5 7.0

4.86.0

Unit : mm

Platform DiameterHeight (H)

IIXY440IIXY640

IIXY455IIXY655

IIXY470IIXY670

4.0 5.5 7.0

4.86.0

Unit : mm

Platform Diameter(D)Height (H)

ILS440ILS640

ILS455ILS655

ILS470ILS670

4.0 5.5 7.0

Excellent Solid Positioning Cylinder

Solid Lab Analog

03 - It is available in three height to accommodate vertical requirements(4.0, 5.5, 7.0mm)

- Instrumentation required 4.8 : Excellent solid driver and 6.0 : 1.2Hex driver

- Packing unit : Included excellent solid healing cap- Torque recommendation : 30Ncm

Excellent Solid Abutment

4.86.0

Unit : mm

Platform DiameterLength (L)

IAX440IAX640

IAX455IAX655

IAX470IAX670

4.0 5.5 7.0

H

L

H

H

H

D

55SHINSAEGI MEDI-TECH

IST & IT System

4.86.0

Unit : mm

Platform Diameter(D)Height (H)

ILX440ILX640

ILX455ILX655

ILX470ILX670

4.0 5.5 7.0

Excellent Solid Impression Cap

4.86.0

IIXC480IIXC600

Unit : mm

Platform Diameter(D) Code

Excellent Solid Impression Shoulder Analog

4.86.0

IIXL480IIXL600

Unit : mm

Platform Diameter(D) Code

Excellent Solid Impression Shoulder Analog Pin

4.86.0

IIXN480IIXN600

Unit : mm

Platform Diameter(D) Code

Excellent Solid Lab Analog

Excellent Solid Plastic Coping

4.8

6.0

Single(Red)

Bridge(White)

Single(Red)

Bridge(White)

IIXP48S

IIXP48B

IIXP60S

IIXP60B

Unit : mm

Platform Diameter Color Code

H

D

D

D

Single Bridge

56 SHINSAEGI MEDI-TECH

Prosthetic Flow Diagrams For IST And IT System

Cement and Screw Retained restoration for In-Octa Cemented Abutment, In-Octa Gold Abutment, Solid Angled Abutment, In-Octa Locking Abutment.

In-Octa Impression Coping(Pick-up)

In-Octa Lab Analog

ALIA In-Octa Locking Lab Analog(Upper) (Lower)

In-Octa Gold Abutment(Octa, Non-Octa)

In-Octa Cement Abutment(Octa, Non-Octa)

ALIPS Driver ALIPS Locking Screw

In-Octa CementedAbutment

Screw

ALIA In-Octa LockingAbutment Screw

1.2Hex Torque Driver

Solid Angled Abutment(Octa)

ALIA In-Octa Locking Abutment

Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)

Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

46p

52p

69p68p68p58p

57p

59p

59p

57p

57p

57p

57p

52p 52p

58p

58p

58p

58p

69p

67p

50p

In-Octa YK Transfer Adapter & Screw (IST&IT)

Impression Plastic Cap

Repositioning Jig

57SHINSAEGI MEDI-TECH

- Cement retained restoration - Angulation : 15 , 25- Packing unit : Included abutment screw(ISAT001)- Torque recommendation : 30Ncm

Solid Angled Abutment

IST & IT System

04

ISAT001

Unit : mm

Code

1525

IAA150IAA250

Unit : mm

Angle( ) Code

- Cement retained restorations - Collar height : 0, 1, 2, 3, 4mm- For use in single tooth or multiple unit restoration - Packing unit : Included abutment screw (ISCT001)- Torque recommendation : 30Ncm

In-Octa Cemented Abutment05

-Instrumentation required 1.2hex driverSolid Angled Abutment Screw

ISCT001

Unit : mm

Code

- Instrumentation required 1.2hex driverIn-Octa Cemented Abutment Screw

4.8

6.0

Unit : mm

FixturePlatform (D)

TypeG/H

IAC407O

IAC407N

IAC607O

IAC607N

IAC417O

IAC417N

IAC617O

IAC617N

IAC427O

IAC427N

IAC627O

IAC627N

IAC437O

IAC437N

IAC637O

IAC637N

IAC447O

IAC447N

IAC647O

IAC647N

Octa

Non-Octa

Octa

Non-Octa

0 1.0 2.0 3.0 4.0

- For use In-octa cemented abutment- ALIPS(Anti Lock Inner Post Screw)- Instrumentation required ALIPS driver

ALIPS Locking Abutment Screw

4.86.0

ISAP001

Unit : mm

Platform Code

7

75.54

D

Octa Non-Octa

58 SHINSAEGI MEDI-TECH

IST & IT System

6.0 (Wide)

4.8 (Regular)

- Instrumentation required 1.2Hex DriverIn-Octa Locking Abutment ScrewUnit : mm

FixturePlatform

Length (L)

SSLR5515H SSLR5525H SSLR5535H SSLR5545H

SSLW6515H SSLW6525H SSLW6535H SSLW6545H

109 11 12

- Packing unit : Included Upper+LowerIn-Octa Locking Lab Analog

In-Octa YK Transfer Adapter

4.8

6.0

1.53.51.53.5

ITLR150ITLR350ITLW150ITLW350

Unit : mm

Fixture Platform G/H Code

4.8

6.0

UpperLowerUpperLower

ILTL481ILTL482ILTL601ILTL602

Unit : mm

Fixture Platform Type Code

In-Octa YK Transfer Adapter Screw

911

ISTL090ISTL110

Unit : mm

Length (L) Code

6.0 (Wide)

4.8 (Regular)

- Screw retained restoration - Octagone base for antirotation locking with a locking abutment screw- Packing unit : IALR Series + SSLR Series, IALW Series + SSLW Series- Torque required : 30Ncm

In-Octa Locking Abutment (Octa)

Unit : mm

FixturePlatform

Diameter(D)

G/H

IALR515O

IALW615O

IALR525O

IALW625O

IALR535O

IALW635O

5.06.0

1.5 2.5 3.5

D

D

G/H

L

L

(Upper) (Lower)

Impression Plastic CapSIYC 600

Unit : mm

Code

59SHINSAEGI MEDI-TECH

IST & IT System

- Instrumentation required 1.2Hex Driver

- Instrumentation required 1.2Hex Driver

- Gold Alloy- Packing unit : Included abutment screw ISCT001- Torque recommendation : 30Ncm

In-Octa Gold Abutment

4.8

6.0

OctaNon-Octa

OctaNon-Octa

IAGI48O

IAGI48N

IAGI60O

IAGI60N

Unit : mm

Platform Diameter (D) Type Code

In-Octa Impression Coping (Transfer)

4.8

6.0

OctaNon-Octa

OctaNon-Octa

IITI48O

IITI48N

IITI60O

IITI60N

Unit : mm

Platform Diameter Type Code

- Packing unit : Included Guide pinIn-Octa Impression Coping (pick-up)

4.8

6.0

OctaNon-Octa

OctaNon-Octa

IIPI48O

IIPI48N

IIPI60O

IIPI60N

Unit : mm

Platform Diameter Type Code

In-Octa Guide Pin(pick-up)

19 ISGI19O

Unit : mm

Height (H) Code

In-Octa Guide Pin(Transfer)

ISGT100

Unit : mm

Code

In-Octa Lab Analog

4.86.0

ILC400ILC600

Unit : mm

Platform Diameter Code

Octa Non-Octa

Octa Non-Octa

60 SHINSAEGI MEDI-TECH

Prosthetic Flow Diagram For IST And IT System

Screw Retained Restoration Component for Octa Abutment

Octa Driver Octa Abutment

Octa Healing Cap

Octa Lab Analog

(Gold) (Ti)Cylinder Screw

1.2Hex Torque Driver

(Octa) (Non-Octa)Octa Impression Coping(Pick-up)

(Octa) (Non- Octa)Octa Gold Cylinder

(Octa) (Non- Octa)Octa Plastic Cylinder

Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)

Cover Screw Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

46p

52p 52p

61p

61p

62p

61p 61p

62p

62p

68p

52p

67p

68p

50p

61SHINSAEGI MEDI-TECH

- Screw retained restoration- Instrumentation required octa driver- Torque recommendation : 30Ncm

Octa Abutment

IST & IT System

06

4.86.0

IAO100

Unit : mm

Platform Diameter Code

- For use protect for octa abutment- Included Ti screw(ISOC400)- Instrumentation required 1.2Hex Torque driver- Torque recommendation : 20Ncm

Octa Abutment Healing Cap

4.86.0

ICO400ICO600

Unit : mm

Platform Diameter Code

- Gold alloy- Packing unit : Included abutment screw(ISOC400)- Torque recommendation : 20Ncm

Octa Gold Cylinder

4.8

6.0

Octa

Non-Octa

Octa

Non-Octa

IAGO48O

IAGO48N

IAGO60O

IAGO60N

Unit : mm

Platform Type Product

- Packing unit : Included cylinder screw (ISOC400)- Torque recommendation : 30Ncm

Octa Plastic Cylinder

4.8

6.0

Octa

Non-Octa

Octa

Non-Octa

IAPY48O

IAPY48N

IAPY60O

IAPY60N

Unit : mm

Platform Type Product

Octa Non-Octa

62 SHINSAEGI MEDI-TECH

IST & IT System

- Packing unit : Included guide pinOcta Impression Coping (pick-up)

4.8

6.0

Octa

Non-Octa

Octa

Non-Octa

IIPO48O

IIPO48N

IIPO60O

IIPO60N

Unit : mm

Platform Diameter Type Product

- Instrument required 1.2Hex Torque driverGuide Pin (pick-up)

15 ISGO15O

Unit : mm

Height (H) Product

Octa Lab Analog

4.86.0

ILO40O

ILO60O

Unit : mm

Platform Diameter Product

- Instrument required 1.2Hex Torque driverOcta Abutment and Cylinder Screw

ISOC40O

Unit : mm

Code

Octa Non-Octa

Gold Ti

63SHINSAEGI MEDI-TECH

Overdenture Retained Restoration for O-Ring Abutment

O-Ring Abutment

O-Ring Lab Analog

Retainer

Prosthetic Flow Diagram For IST And IT System

O-Ring Abutment Driver(2.4Hex)

Internal Slightly Fixture(IST) Internal Tapered Fixture(IT)

Internal Cover Screw Internal Headless Cover Screw Healing Abutment 1.2Hex Hand Driver

46p

52p 52p

64p

64p

64p

68p

52p

67p

50p

For Denture O-Ring(Red)

For Laboratory O-Ring(Black)

64p 64p

64 SHINSAEGI MEDI-TECH

IST & IT System

- Overdenture restoration- Multiple implant bone retained and fixed removable overdentures.- Collar height : 0, 2, 4mm- Packing unit : Included O-Ring 2ea and O-Ring retainer 1ea- Instrument required O-Ring abutment driver(2.4Hex)- Torque recommendation : 30Ncm

O-Ring Abutment07

3.5

Unit : mm

Diameter (D)Length (L)

IAR400 IAR420 IAR4400 2.0 4.0

O-Ring

Red(Denture)

Black(Laboratory)

IARR002IARR003

Unit : mm

Type Code

- Female receptacle processed into dentureO-Ring Retainer

IARR001

Unit : mm

Code

O-Ring Lab Analog

RL001

Unit : mm

Code

L

D

65SHINSAEGI MEDI-TECH

SHINSAEGI MEDI-TECH

Surgical

InstrumentEsthetic & Innovation

Surgical Instrument

66 SHINSAEGI MEDI-TECH

Guide DrillStraight DrillTapered DrillHand DriverMachine DriverTorque DriverFixture Mount DriverDepth gaugeDrill ExtensionLocking Abutment ScrewALIPS DriverPositioning GuideParallel PinTorque WrenchHolding KeyBone Profiler & Guide PinPath PinReamer HandleReamer GuideReamer BiteBone MillTissue PunchDrill SystemSurgical Drilling ProtocolDrill DimensionsSurgical ProtocolSurgical Kit Contents

67p67p67p67p68p68p68p69p69p69p69p69p69p69p69p70p70p70p70p70p70p70p71p71p71p72p74p

67SHINSAEGI MEDI-TECH

- This drill has a unique pointed tip, making this an excellent drill for starting the osteotomy.

Guide Drill

Surgical Instrument

Lance KRG160 Start drill

Unit : mm

Type Code Application

- Tapered series of drills follows in order to increase the width of the osteotomy to correspond to the diameter of the implant being placed.

Tapered Drill

- This drills are designed to increase the depth of the osteotomy.

2.0

79

11131517

KRS2007KRS2009KRS2011KRS2013KRS2015KRS2017

Depth drill

Unit : mm

Diameter Length Code Application

2.0/2.8

2.0/3.3

2.1/3.6

2.5/4.0

2.8/4.5

3.2/4.8

3.3/5.0

4.0/5.8

Short( 7, 9, 11)

Long (13, 15, 17)

Short( 7, 9, 11)

Long (13, 15, 17)

Short( 7, 9, 11)

Long (13, 15, 17)

Short( 7, 9, 11)

Long (13, 15, 17)

Short( 7, 9, 11)

Long (13, 15, 17)

Short( 7, 9, 11)

Long (13, 15, 17)

Short( 7, 9, 11)

Long (13, 15, 17)

Short( 7, 9, 11)

Long (13, 15, 17)

KRT2028S

KRT2028L

KRT2033S

KRT2033L

KRT2136S

KRT2136L

KRT2540S

KRT2540L

KRT2845S

KRT2845L

KRT3248S

KRT3248L

KRT3350S

KRT3350L

KRT4058S

KRT4058L

Width increasing drill

Unit : mm

Diameter Length Code Application

- For use tip-holding function by handHand Driver

External 1.2Hex

External 0.9Hex

Short

Long

Short

Long

KDH120S

KDH120L

KDH090S

KDH090L

Healing abutment, UCLA Abutment screw, Internal cover screw

External cover screw(N, R, W, W6.0)

Unit : mm

Diameter Length Code Application

Straight Drill

1.2Hex 0.9Hex

68 SHINSAEGI MEDI-TECH

Surgical Instrument

- For use Torque Wrench- For use Torque function

External 1.2Hex

External 0.9Hex

Internal 2.0Hex

Internal 2.4Hex

Internal 2.7Hex

Solid Driver

Ex-Solid Driver

Octa Driver

Short

Long

Short

Long

Short

Long

Short

Long

Short

Long

Short

Long

Short

Long

Short

Long

KDT120S

KDT120L

KDT090S

KDT090L

KDT200S

KDT200L

KDT240S

KDT240L

KDT270S

KDT270L

KDTS00S

KDTS00L

KDTE00S

KDTE00L

KDT300S

KDT300L

Healing abutment, UCLA Abutment screw, Internal cover screw

External cover screw(N, R, W, W6.0)

Estheticone and Midicone Abutment screw

All of O-Ring Abutment

Widecone Abutment screw

Solid Abutment

Excellent Solid Abutment

Octa Abutment

Unit : mm

Diameter Length Code Application

- For pick-up and delivery of Implant

Narrow( 3.5)Hand piece

Regular( 4.1)Hand piece

Wide( 5.1)Hand piece

Narrow( 3.5)Ratchet

Regular( 4.1)Ratchet

Wide( 5.1)Ratchet

All of Size(Sub)Hand piece

All of Size(Sub)Ratchet

All of Size(Internal)Hand piece

All of Size(Internal)Ratchet

Hex

Hex

Hex

Hex

Hex

Hex

Hex

Hex

Octa

Octa

Long

Long

Long

Short

Long

Short

Long

Short

Long

Long

Short

Long

Long

Short

Long

KDMM240L

KDMM270L

KDMM340L

KDTM240S

KDTM240L

KDTM270S

KDTM270L

KDTM340S

KDTM340L

KDMM250L

KDTM250S

KDTM250L

KDMM310L

KDTM310S

KDTM310L

For use External implant(EST Series)

For use Submerged Implant(SST Series)

For use Internal implant(IST&IT Series)

Unit : mm

Diameter Length Length Code Application

- For use hand-piece of Motor

External 1.2Hex

External 0.9Hex

Short

Long

Short

Long

KDM120S

KDM120L

KDM090S

KDM090L

Healing abutment, UCLA Abutment screw, Internal cover screw

External cover screw(N, R, W, W6.0)

Unit : mm

Diameter Length Code Application

Fixture Mount Driver

Torque Driver

Machine Driver

1.2Hex

External Type

Interal Type

Modrine

Torque

EST

EST SST IST & IT

SST IST & IT

0.9Hex

69SHINSAEGI MEDI-TECH

Surgical Instrument

- Measurement of drilling depth(EST, SST, IST, IT Implant)

7, 9, 11, 13, 15, 17 KID170

Unit : mm

Depth Length Code

- Using for insert implant and tie-up driver

15, 25, 35 Ncm KIT450

Unit : mm

Torque Power Code

- Measurement of fixture space

810

KIG080KIG100

Unit : mm

Unit : mm

Width(D) Code

- Measurement of direction and situation

45

KIP400KIP500

Unit : mm

Width(D) Code

- For use drill extension on hand-piece

KIE300

Unit : mm

Code

Depth gauge

Positioning Guide

Parallel Pin

Torque Wrench

Drill Extension

- For use locking abutment screw

KDHAL110

Unit : mm

Code

Repositioning Jig

- For use ALIPS abutment

KDHAP130Code

ALIPS Driver

- Holding for Torque Wrench

KIK850

Unit : mm

Code

Holding Key

D

D

70 SHINSAEGI MEDI-TECH

Surgical Instrument

Reamer Bite

KIRB

Unit : mm

Code

- For formation of particulate bone with autogenous bone.Bone Mill

KIBM

Unit : mm

Code

- Flapless surgery- Laser marking 2, 4, 6mm for easy measurement of gingiva height.

4.14.65.36.3

KICM410KICM460KICM530KICM630

EST, SST(Narrow)

EST, IT, IST, SST(Regular)

EST, IT, IST, SST(Wide)

EST, SST(Wide 6.0)

Unit : mm

D Code Application

Tissue Punch

4.55.56.5

KIRG450KIRG550KIRG650

Unit : mm

Width Code

- Measurement of path and gingival height

KIH250

Unit : mm

Code

Path Pin

KIRH

Unit : mm

Code

Reamer Handle

Reamer Guide

- For remove from surplus bone

3.64.155.156.054.85

KIBN360KIBR415KIBW515KIBW605KIBW485

Unit : mm

Fixture platform Interface Diameter Code

Bone Profiler & Guide Pin

3.5 (Narrow)

4.1 (Regular)

5.1 (Wide)

6.0 (W6.0)

4.8 (N, R, W)

71SHINSAEGI MEDI-TECH

Drill System

Drill (Straight & Tapered Drill)

Surgical Drilling Protocol

Drill Dimensions

Tapered Drill ( 2.0/2.8) ( 2.0/3.3) ( 2.1/3.6) ( 2.5/4.0) ( 2.8/4.5) ( 3.2/4.8) ( 3.3/5.0) ( 4.0/5.8) (mm)A series of tapered drills are width drill in order to increase the width of the osteotomy to correspond to the diameter of the implant being placed.Regardless of the tapered drills diameter, the length of the drill tip is 0.3mmThe length of the drill tip is not included in the depth mark measurement.

Straight Drill( 2.0)Proceed with the initial straight drill to 7mm, 9mm, 11mm, 13mm, 15mm, 17mm with stopper.

2.0mm is designed to increase the depth of the osteotomy.Thread floss through the hole to prevent accidental swallowing.

2.0 straight drills, the length of the drill tip is 0.5mm.The length of the drill tip is not included in the depth mark

measurement.Consist of the diameter 2.0mm straight drills are 7. 9. 11, 13, 15, 17mm length with stopper and not marking system.

EST

3.54.14.15.13.84.35.06.04.84.86.0

3.44.05.05.93.74.24.95.94.14.85.3

2.42.93.64.32.42.93.64.3

2.4 3.43.4 4.14.0 4.6

SST

ISTIT

Product

2.0mm(straight)

2.0/2.8mm(tapered)

2.0/3.3mm(tapered)

2.1/3.6mm(tapered)

0.5mm

7mm(with stopper)

9mm(with stopper)

11mm(with stopper)

13mm(with stopper)

15mm(with stopper)

17mm(with stopper)

7, 9, 11mm(marking with stopper)

13, 15, 17mm(marking)

7, 9, 11mm(marking with stopper)

13, 15, 17mm(marking)

7, 9, 11mm(marking with stopper)

13, 15, 17mm(marking)

0.3mm

2.5/4.0mm(tapered)

2.8/4.5mm(tapered)

3.2/4.8mm(tapered)

3.3/5.0mm(tapered)

4.0/5.8mm(tapered)

-

0.3mm

0.3mm

0.3mm

0.3mm

0.3mm

-

7, 9, 11mm(marking with stopper)

13, 15, 17mm(marking)

7, 9, 11mm(marking with stopper)

13, 15, 17mm(marking)

7, 9, 11mm(marking with stopper)

13, 15, 17mm(marking)

7, 9, 11mm(marking with stopper)

13, 15, 17mm(marking)

7, 9, 11mm(marking with stopper)

13, 15, 17mm(marking)

-

0.3mm

0.3mm

Drill DiameterDrill TipLength

Drill Length Drill DiameterDrill TipLength

Drill Length

Platform Body Apex Guide 2.0 2.0/2.8 2.0/3.3 2.1/3.6 2.5/4.0 2.8/4.5 3.2/4.8 3.3/5.0 4.0/5.8

Guide Drill Tapered DrillStraight Drill

72 SHINSAEGI MEDI-TECH

Surgical Protocol

External Slightly Tapered Fixture (EST System)

: Guide 2.0mm Straight Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture

D4BoneD3,D2BoneD1Bone

3.4mm Fixture01

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.0/3.3mm Tapered Drill

Fixture0.5mm

4.0mm Fixture

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.5/4.0mm Tapered Drill

Fixture0.5mm

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

D4BoneD3,D2BoneD1Bone

02

5.0mm Fixture

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill

Fixture0.5mm

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill Fixture

D4BoneD3,D2BoneD1Bone

03

5.9mm Fixture

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.8/4.5mm Tapered Drill

3.3/5.0mm Tapered Drill

4.0/5.8mm Tapered Drill

Fixture0.5mm

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill

3.3/5.0mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill

3.3/5.0mm Tapered Drill 4.0/5.8mm Tapered Drill Fixture

D4BoneD3,D2Bone

D1Bone

04

73SHINSAEGI MEDI-TECH

Surgical Protocol

Submerged Slightly Tapered Fixture (SST System)

3.7mm Fixture01

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.0/3.3mm Tapered Drill

2.1/3.6mm Tapered Drill

Fixture0.5mm

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture

D4BoneD3,D2BoneD1Bone

4.2mm Fixture02

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.5/4.0mm Tapered Drill

Fixture0.5mm

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

D4BoneD3,D2BoneD1Bone

4.9mm Fixture03

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill

Fixture0.5mm

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill Fixture

D4BoneD3,D2BoneD1Bone

5.9mm Fixture

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.8/4.5mm Tapered Drill

3.3/5.0mm Tapered Drill

4.0/5.8mm Tapered Drill

Fixture0.5mm

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture

3.3/5.0mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill

3.3/5.0mm Tapered Drill 4.0/5.8mm Tapered Drill Fixture

D4BoneD3,D2Bone

D1Bone

04

74 SHINSAEGI MEDI-TECH

Surgical Protocol

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill

3.3/5.0mm Tapered Drill

0.5mm

Internal Slightly Tapered Fixture (IST System)Internal Tapered Fixture(IT System)

4.1mm Fixture01

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.5/4.0mm Tapered Drill

Fixture(IST)

Fixture(IT)

0.5mm

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

- IST & IT model are same diameter and same protocol.

D4BoneD3,D2BoneD1Bone

4.8mm Fixture02

Fixture(IST)

Fixture(IT)

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill

2.8/4.5mm Tapered Drill Fixture

D4BoneD3,D2BoneD1Bone

15mm

Guide 2.0mmStraight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.5/4.0mm Tapered Drill

2.8/4.5mm Tapered Drill

0.5mm

5.3mm Fixture03

Fixture(IST)

Fixture(IT)

: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill

3.2/4.8mm Tapered Drill Fixture: Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill 3.3/5.0mm Tapered Drill Fixture

D4BoneD3,D2Bone

D1Bone

75SHINSAEGI MEDI-TECH

Surgical Kit

External Kit (EST)

Internal Kit (SST, IST, IT)

76 SHINSAEGI MEDI-TECH

Surgical Kit Contents

External Kit(EST)No Type Length Q'Ty Application

Guide Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0/2.8 Tapered Drill(S)2.0/2.8 Tapered Drill(L)2.0/3.3 Tapered Drill(S)2.0/3.3 Tapered Drill(L)2.1/3.6 Tapered Drill(S)2.1/3.6 Tapered Drill(L)2.5/4.0 Tapered Drill(S)2.5/4.0 Tapered Drill(L)3.2/4.8 Tapered Drill(S)3.2/4.8 Tapered Drill(L)3.3/5.0 Tapered Drill(S)3.3/5.0 Tapered Drill(L)4.0/5.8 Tapered Drill(S)4.0/5.8 Tapered Drill(L)

Drill extensionFixture Mount Driver(Machine) NarrowFixture Mount Driver(Machine) RegularFixture Mount Driver(Machine) WideFixture Mount Driver(Torque) Narrow(L)Fixture Mount Driver(Torque) Narrow(S)Fixture Mount Driver(Torque) Regular(L)Fixture Mount Driver(Torque) Regular(S)Fixture Mount Driver(Torque) Wide(L)Fixture Mount Driver(Torque) Wide(S)Hex 0.9 Driver for Hand(L)Hex 0.9 Driver for Hand(S)Hex 0.9 Driver for Machine(L)Hex 0.9 Driver for Machine(S)Hex 0.9 Driver for Torque(L)Hex 0.9 Driver for Torque(S)Hex 1.2 Driver for Hand(L)Hex 1.2 Driver for Hand(S)Hex 1.2 Driver for Machine(L)Hex 1.2 Driver for Machine(S)Hex 1.2 Driver for Torque(L)Hex 1.2 Driver for Torque(S)Hex 2.0 Driver(L)Hex 2.0 Driver(S)Hex 2.7 Driver(L)Hex 2.7 Driver(S)Hex 2.4 Driver(L)Hex 2.4 Driver(S)

7mm9mm

11mm13mm15mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm

11111111111111111111111111111111111111111111111111111111

Start DrillDepth DrillDepth DrillDepth DrillDepth DrillDepth DrillDepth DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillFor use drill and handpiece tools extensionMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for ExternalMountless delivery for External

External Cover Screw(N, R, W, W6.0)

Abutment ScrewHealing Abutment, Locking Abutment Screw,Cylinder Screw

For Estheticone, MidiconeFor Estheticone, MidiconeFor WideconeFor WideconeFor O-RingFor O-RingMeasurement of direction and situationMeasurement of direction and situationMeasurement of fixture spaceMeasurement of fixture spaceInsert implant and tie-up driverHolding for Torque WrenchMeasurement of drilling depth

1

2

34567891011121314151617181920212223242526272829303132333435363738394041424344

45

46

Parallel Pin

Positioning Guide

Torque Wrench 45N cmHolding KeyDepth Gauge

4mm5mm8mm

10mm

7~17mmTotal 56

474849

No Type Length Q'Ty Application

Guide Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0 Straight Drill2.0/2.8 Tapered Drill(S)2.0/2.8 Tapered Drill(L)2.0/3.3 Tapered Drill(S)2.0/3.3 Tapered Drill(L)2.1/3.6 Tapered Drill(S)2.1/3.6 Tapered Drill(L)2.5/4.0 Tapered Drill(S)2.5/4.0 Tapered Drill(L)2.8/4.5 Tapered Drill(S)2.8/4.5 Tapered Drill(L)3.2/4.8 Tapered Drill(S)3.2/4.8 Tapered Drill(L)3.3/5.0 Tapered Drill(S)3.3/5.0 Tapered Drill(L)

Drill extensionFixture Mount Driver for Machine(Hex)(L)Fixture Mount Driver for Torque (L)Fixture Mount Driver for Torque (S)Fixture Mount Driver for Machine(Octa)(L)Fixture Mount Driver for Torque (L)Fixture Mount Driver for Torque (S)Hex 1.2 Driver for Hand(L)Hex 1.2 Driver for Hand(S)Hex 1.2 Driver for Machine(L)Hex 1.2 Driver for Machine(S)Hex 1.2 Driver for Torque(L)Hex 1.2 Driver for Torque(S)Octa Driver for Torque(L)Octa Driver for Torque(S)Solid Driver for Torque(L)Solid Driver for Torque(S)Excellent Solid Driver for Torque(L)Excellent Solid Driver for Torque(S)Hex 2.4 Driver for Torque(L)Hex 2.4 Driver for Torque(S)

7mm9mm11mm13mm15mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm11mm17mm

1111111111111111111111111111111111111111111111111

Start DrillDepth DrillDepth DrillDepth DrillDepth DrillDepth DrillDepth DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillWidth Increasing DrillFor use drill and handpiece tools extensionMountless delivery for Internal Hex(SST)Mountless delivery for Internal Hex(SST)Mountless delivery for Internal Hex(SST)Mountless delivery for Internal Octa(IST/IT)Mountless delivery for Internal Octa(IST/IT)Mountless delivery for Internal Octa(IST/IT)Cover Screw, Abutment ScrewHealing Abutment,

6.0 Excellent Solid Abutment,Locking Abutment Screw,In-Octa Cemented Abutment,Sub Solid Abutment, Cylinder Screw

Octa Abutment

Solid Abutment

Excellent Solid Abutment

O-Ring Abutment

Measurement of direction and situation

Measurement of fixture space

Insert implant and tie-up driverHolding for Torque WrenchMeasurement of drilling depth

1

2

3456789

10111213141516171819202122232425262728293031323334353637

38

39

404142

Parallel Pin

Positioning Guide

Torque Wrench 45N cmHolding KeyDepth Gauge

4mm5mm8mm10mm

7~17mmTotal 49

Internal Kit(SST, IST, IT)

No Type Length Q'Ty Application

Bone Profile and Guide Pin

Path PinReamer Handle

Reamer Guide

Reamer BiteBone Mill

Tissue punch

3.64.155.156.054.85

4.55.56.5

4.14.65.36.3

1111111111111111

For remove from surplus bone.

Measurement of path and height gingiva

For Particulate bone generation by autogenous bone.Flaplees Surgery for EST, SST (Narrow)Flaplees Surgery for EST, IT, IST, SST(Regular)Flaplees Surgery for EST, IT, IST, SST(Wide)Flaplees Surgery for EST, SST(Wide 6.0)

1

2

3

4

56

7

Total 16

Option