Vertical, Horizontal & Skidded Heater Treaters
Design Conditions RequiredWhat we need to know before recommending a specific Heater Treater:
OperatingPressure
OilRateBBL/Day
WaterRateBBL/Day
FlowingTemperature
APIGravityofOil
SourGas
CO2
A
F
G G
A G
G
H
I
J
K
L
B
C
D
E
E
E
F
C
B
C B D L
LLC
LLC
J
K
H
INLET - OIL, GAS, WATER
SHROUD
FIRETUBE
BAFFLE
HEAT
GAS
TREATED WATER
TREATED OIL
EMULSION
FREE WATER KNOCKOUT SECTION CONTAINS OIL & WATER
(2) VERTICAL COLLECTOR PIPES FOR TREATED OIL
CONDUCTOR PIPES & OUTLET DISTRIBUTOR
MAY SECTION
TREATED OIL OUTLET
TREATED WATER OUTLET
GAS OUTLET
DOWNCOMER FROM F.W.K.0. SECTION INTO SHROUD
Tre
ate
d O
il
Wate
rG
as
Un
tre
ate
d
HEAT
GAS
TREATED WATER
TREATED OIL
EMULSION
Tre
ate
d O
il
Wate
rG
as
Un
tre
ate
d
HEAT
GAS
TREATED WATER
TREATED OIL
EMULSION
Performance. Value. Check.
des-co.com
Diameter x height, feet 4x20 6x20 8x20 10x20
WorkingPressure,PSI 50 or 75 50 or 75 50 or 75 50 or 75
Oiltreatingcapacity,bbl/day 100-500 200-1000 500-1600 800-2750
Gascapacity,MMCFD 1-2 2-4 3-6 5-9
Fireboxcapacity,BTU/HR 360,000 500,000 1,000,000 1,300,000
Fireboxarea(ft2) 36 52 100 126.67
Firetubesize(in) 16 16 24 24
Stacksize 8 8 16 16
Settlingsectionvolume,bbl 19 43 72 112
Totaloilandwatervolume,bbl 34.2 80.3 143 224
Inletsize(in) 3 3 4 4
Outletsize(in) 3 3 4 4
Wateroutletsize(in) 3 3 4 4
Gasoutleltsize(in) 3 3 4 4
DrainsizeSiphonType)(in) 3 3 3 3
Reliefvalvesize(in) 2 2 2 2
No.of16manways 2 2 2 2
Shippingweight(lbs) 6,000 8,500 11,500 15,750