desalination
DESCRIPTION
hhhTRANSCRIPT
![Page 1: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/1.jpg)
WELCOME
TO PRESENTATION ON
TA5
WATER TREATMENT PLANT
![Page 2: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/2.jpg)
SEA WATER INTAKE 7800 CuM
TA4 CWPH
4500 CuM
TA5 WCTP SYSTEM - 3300 CuM
DM WATER FOR BOILER
UTILITY SERVICE WATER
POTABLE WATER FOR PLANT
SERVICE WATER FOR PLANT
POTABLE WATER FOR TOWNSHIP
![Page 3: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/3.jpg)
WATER INTAKE FROM SEA
PRE TREATMENT
PLANT
FILTERED WATER TANK
UF SKID FIRST PASS RO
SECOND PASS RO
UF PERMEATE CUM BACK
WASH TANK
FIRST PASS RO PERMEATE
WATER STORAGE TANK
SECOND PASS RO PERMEATE
WATER STORAGE TANK
MIXED BED RO
DM TANKS
UTILITY SERVICE WATER
POTABLE WATER TANK
POTABLE WATER FOR PLANT
SERVICE WATER FOR PLANT
POTABLE WATER FOR TOWNSHIP
LIME STONE FILTER
TA5 PROCESS FLOW DIAGRAM
![Page 4: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/4.jpg)
WATER INTAKE FROM SEA
PRE TREATMENT
PLANT
FILTERED WATER TANK
UF SKID FIRST PASS RO
SECOND PASS RO
UF PERMEATE CUM BACK
WASH TANK
FIRST PASS RO PERMEATE
WATER STORAGE TANK
SECOND PASS RO PERMEATE
WATER STORAGE TANK
MIXED BED RO
DM TANKS
UTILITY SERVICE WATER
POTABLE WATER TANK
POTABLE WATER FOR PLANT
SERVICE WATER FOR PLANT
POTABLE WATER FOR TOWNSHIP
LIME STONE FILTER
TA5 PROCESS FLOW DIAGRAM
Flow 3300 Cum/HrTDS 35000 ppmTSS 200 ppmSp.Gr 1.03
Flow 3000 Cum/HrTSS 2 ppm
Flow 2300 Cum/Hr
SDI < 3
Flow 810 Cum/HrTDS 400 ppmTSS Nil
Flow 215 Cum/Hr
Flow 180 Cum/HrTDS 20 ppm
Flow 150 Cum/HrPH 6.8 – 7.2Silica < 0.01 ppmCond < 0.1 MicrosiemensNa & CO2 Nil
F 485
F 30 F 20 F 60
CO2 - Nil
![Page 5: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/5.jpg)
LAMELLA CLARIFIER –
16 Cone Sectors
GRAVITY SAND FILTER
FROM SEA WATER
TURBIDITY 200 NTU AT INLET
TURBIDITY <2 NTU AT OUTLET OF PRE TREATMENT PLANT. NO
CHEMICAL CHANGE
SLUDGE SUMP 200 CUM
TO REJECT
3 Nos Vertical pumps to Feed UF feed
3 Nos Vertical pumps for GSF backwash & 3 Nos of Twin Lobe Blowers
FILTERED WATER TANK
STILLING CHAMBER
FLASH MIXER
FLOCULLATOR
Desalination Feed Pump
House – TA5
For TA4 - CWPH
NaoCl dosage
from ECP to remove
ALGAE
FeCl 3 Coagulant dosage to remove
TURBIDITY
Coagulant aid – Polyelectrolyte
- dosage to remove
COLLOIDAL SILICA
TA5 – PRE TREATMENT PLANT SCHEME
To TA4
Reject from Clarifier
B/W from GSF
TURBIDITY 50 NTU
![Page 6: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/6.jpg)
PRE TREATMENT PROCESS• STILLING CHAMBER – NaOCl is added – To
remove ALGAE.• FLASH MIXER – FeCl3 Coagulant is added – To
remove TURBIDITY.• FLOCULLATOR – Coagulant aid
(Polyelectrolyte) is added – To remove COLLOIDAL SILICA.
• LAMELLA CLARIFIER – To filter TURBIDITY upto 50 NTU.
• GSF – To filter TURBIDITY TO < 2 NTU.
![Page 7: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/7.jpg)
TA5 – UF & FIRST PASS RO
RO CARTRIDGE FILTER 3 Nos
FIRST PASS RO PERMEATE
WATER STORAGE TANK
Reverse Osmosis 1 Skid - 3 Nos
To RejectIst PASS RO ERU
UF PERMEATE CUM BACK
WASH TANK
Basket Strainer8 Nos UF Skid
REJECT TANK
UF B/W
I Pass Cartridge Filter Feed Pump
Filtered Water
Storage Tank
3 Nos Vertical feed pumps from Under Ground RCC tank
To 2nd Pass RO
Service water & Lime stone feed
Antioxident SMBS to Remove Free Cl2
Antiscalant SHMP to Remove all Carbonates alkalinity
Acid/ Lye for PH correction (6 to 7)
![Page 8: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/8.jpg)
FIRST PASS RO PERMEATE WATER STORAGE TANK
3 Nos. Mixed Bed 2 Nos. DM TANK
2nd Pass Cartridge Filter 3 Nos
2nd Pass RO HPP 3 Nos
2nd Pass DG Feed Pump
2nd Pss DG Air Blower 3 Nos
Reject to Permeate cum B/W Tank
SECOND PASS RO PERMEATE
WATER STORAGE TANK
Reverse Osmosis 2 Skid -3 Nos
DM WATER TO CST
2 Nos. DM TRANSFER PUMP
TA5 - II PASS RO – MIXED BED
II Pass Cartridge Filter Feed Pump
3 Nos. MB Feed Pump
*SMBS - Free Cl2. *SHMP - Carbonates alkalinity. *Acid/ Lye for PH correction.
![Page 9: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/9.jpg)
MEMBERANES/CARTRIDGES
SYSTEM NUMBER OF MEMBERANES
UF MEMBERANES 896
FIRST PASS CARTRIDGE 920
FIRST PASS MEMBERANES 1281
SECOND PASS CARTRIDGE 72
SECOND PASS MEMBERANES 210
![Page 10: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/10.jpg)
PROCESS PARAMETERSPROCESS QUANTITY in
CUM/HRTDS in ppm TSS in
NTUREMARKS
INTAKE WATER 3300 35000 200 Specific Gravity 1.03
After Lamella Clarifier
50
After GSF 3000 2
After UF Skid 2300
After I Pass RO 810 400 NIL
After II Pass RO 180 20
After Mixed Bed – DM water Qly
150 0.01 PH 6.8 to 7.2, Silica < 0.01ppmCond < 0.1 Microsiemens, Na & CO2 - NIL
Plant water 500 NIL As per IS 10500TDS 500 ppm, TSS NIL, Ca 75 ppm, Mg 50 ppm, Sulphite & Chlorides 200 ppm each, PH 7 to 8.5, CO2 NIL.
![Page 11: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/11.jpg)
TA5 ELECTRO CHLORINATION PLANT
Electrolytic Cell Assembly -
To Generate NaOCl
High Current Low Voltage Cathode: Hastelloy Anode: Titanium
PROCESS: NaCl+H2O → NaOCl + H2
FRP Tankto Store NaOCl –
Sodium Hypo Chlorite solution
Shock Dosing to CWPH
Continuous Dosing to CWPH
To Stilling Chamber in
PT Plant
Sea Water from CWPH Tapping
![Page 12: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/12.jpg)
TA5 EFFLUENT DISPOSAL SYSTEM
Neutralizing Pit
Plant Drain
Effluent Treatment Tank
GUARD POND
From Reject Tank
Back Wash Solutions
from Mixed Bed
Plant Strom water
Acid / Lye Dosing to adjust PH according to
TNPCB norms
TO OPEN DRAIN
![Page 13: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/13.jpg)
TA5 POTABLE WATER SCHEME
Service Water to Plant
Potable Water to Plant
Potable Water to Township2 Nos. Bulk
Caustic Tank
To REJECT
Portable Water Tank
First pass RO Permeate
Water Storage Tank
3 Nos. Lime Stone Filters
CO2 Dosing Motive
Water Pump
2 Nos. CO2 Storage
TankEvaporator
Dosing System
![Page 14: desalination](https://reader036.vdocument.in/reader036/viewer/2022082815/55cf98f0550346d0339a92ee/html5/thumbnails/14.jpg)
THANK YOU