desalineamiento acoplamientos falk

Upload: juanpablogonzalezfiblas

Post on 04-Feb-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/21/2019 Desalineamiento Acoplamientos Falk

    1/2

    Misalignment and End FloatType T (Page 1 of 2)

    Maximum life and minimum maintenance for the coupling andconnected machinery will result if couplings are accuratelyaligned. Coupling life expectancy between initial alignment andmaximum iperating limits is a function of load, speed, andlubrication. Maximum iperatingvalues listed on Page 2 are based

    on catalogued allowable rpm.Values listed in the table herein are based upon the use of thegaps listed , standard components, standard assemblies, andcatalogued allowable speeds.

    Values may be combined for an installation or operating

    condition. Static limits are extremes and cannot be combined.

    Note: For applications requiring greater misalignment, referapplication details to the Factory.Angular misalignment is the dimension X minus Y as illustratedbelow.

    Parallel misalignment is the distance P between the hub centerlines as illustrated below.

    End float (with zero angular and parallel misalignment) is theaxial movement of the hub(s) within the cover(s) measured from0 gap.

    Type T Grid Coupling Misalignment and End Float Inches

    Falk Steelflex Grid Couplings

    Table 1 Recommended Installation Maximum Values

  • 7/21/2019 Desalineamiento Acoplamientos Falk

    2/2

    Falk Steelflex Grid Couplings(Page 2 of 2)

    Misalignment and End FloatType T

    Table 3 Static Limits

    Table 2 Maximum Operating Values