desalineamiento acoplamientos falk
TRANSCRIPT
-
7/21/2019 Desalineamiento Acoplamientos Falk
1/2
Misalignment and End FloatType T (Page 1 of 2)
Maximum life and minimum maintenance for the coupling andconnected machinery will result if couplings are accuratelyaligned. Coupling life expectancy between initial alignment andmaximum iperating limits is a function of load, speed, andlubrication. Maximum iperatingvalues listed on Page 2 are based
on catalogued allowable rpm.Values listed in the table herein are based upon the use of thegaps listed , standard components, standard assemblies, andcatalogued allowable speeds.
Values may be combined for an installation or operating
condition. Static limits are extremes and cannot be combined.
Note: For applications requiring greater misalignment, referapplication details to the Factory.Angular misalignment is the dimension X minus Y as illustratedbelow.
Parallel misalignment is the distance P between the hub centerlines as illustrated below.
End float (with zero angular and parallel misalignment) is theaxial movement of the hub(s) within the cover(s) measured from0 gap.
Type T Grid Coupling Misalignment and End Float Inches
Falk Steelflex Grid Couplings
Table 1 Recommended Installation Maximum Values
-
7/21/2019 Desalineamiento Acoplamientos Falk
2/2
Falk Steelflex Grid Couplings(Page 2 of 2)
Misalignment and End FloatType T
Table 3 Static Limits
Table 2 Maximum Operating Values