desgin of a flat slab
TRANSCRIPT
-
7/28/2019 desgin of a flat slab
1/3
Flat Slabs Page 1 of 3 2005/08/08
Flat Slab Construction
Advantages:
Cheaper shuttering
Flat underside of slab
Disadvantages
Simple analysis limit to certain proportions of slab geometry (see 3.6.6.1 of CP110), otherwise a moreintensive analysis needs to be done.
Example
Design the following slab in accordance with the empirical method of CP110. The concrete has a 28day strength of 25 MPa. On the slab is a 50 mm thick finish with a density of 2000 kg/m
3as well as dry
walling with an average mass of 100 kg/m
2
. The live loading is for an office.
Loading on the slab:
Dead load: Slab =2
/0,61000
10240025,0 mkN=
Finish =2
/0,11000
10200005,0 mkN=
Walls =2
/0,11000
10100mkN=
Total Dead load = 8,0 kN/m2
Live Load: Live load = 2,5 kN/m
2
Factored load = 1,2 x DL + 1,6 X LL = 1,2 x 8,0 + 1,6 x 2,5 = 13,6 kN/m2
-
7/28/2019 desgin of a flat slab
2/3
Flat Slabs Page 2 of 3 2005/08/08
For use in the equation:
2
1
2
3
2
8
= cds
hl
nlM along axis 1, 2, 3 or 4
n = 13,6 kN.m
l1 = 6 ml2 = 5 mhc = 0,3 m
mkNMds .94,2853
3,026
8
56,132
=
=
For use in the equation:
2
1
2
3
2
8
= cds
hl
nlM along axis A, B, C or D
n = 12,16 kN.m
l1 = 5 ml2 = 6 mhc = 0,3 m
mkNMds .01,2353
3,025
8
66,132
=
=
Column Strip along Axis 1 or 4:
Width of the strip = 5,000/4 = 1,250 m
If columns are small use the factors for Wall supports:
Exterior panel exterior negative moments = mkN.16,1794,285100
6=
Exterior panel positive moments = mkN.38,11494,285100
40=
Exterior panel interior negative moments = mkN.72,18894,285100
66=
Exterior Panel Middle strip
Exterior negative moments = mkN.59,2894,28510010 =
Exterior positive moments = mkN.06,8094,285100
28=
Interior negative moments = mkN.63,6894,285100
24=
Column Strip along Axis 2 or 3, Interior panels, without drops:
Width of the strip = 5,000/2 = 2,50 m
-
7/28/2019 desgin of a flat slab
3/3
Flat Slabs Page 3 of 3 2005/08/08
Interior panel negative moments = mkN.53,13194,285100
46=
Interior panel positive moments = mkN.91,6294,285100
22=
Interior Panel Middle strip
Interior panel negative moments = mkN.75,4594,285100
16=
Interior panel positive moments = mkN.75,4594,285100
16=
Reinforcing:
h = 250 mm, use a 25 mm cover and a 20 mm bar diameter. d = 250 25 10 = 215 mm.
For a 1 m wide strip, mkNdbfM curc .34,17321510002515,015,022===
Exterior PanelColumn strip
Mu (kN.m) Mrc/m width(kN.m)
Widthm
Mrc (kN.m) Mu/Mrc % steel
Exterior neg M 17,16 173,34 1,25 216,68 0,08
Positive M 114,38 173,34 1,25 216,68 0,53
Interior neg M 188,72 173,34 1,25 216,68 0,87
Exterior Panelmiddle strip
Exterior neg M 28,59 173,34 1,25 216,68 0,13
Positive M 80,06 173,34 1,25 216,68 0,37Interior neg M 68,63 173,34 1,25 216,68 0,41
Interior PanelColumn strip
Negative M 131,53 173,34 2,50 433,35 0,30
Positive M 62,91 173,34 2,50 433,35 0,15
Interior Panelmiddle strip
Negative M 45,75 173,34 2,50 433,35 0,11
Positive M 45,75 173,34 2,50 433,35 0,11
The same analysis may be carried out for moments in the direction vertical, i.e. along the axes A, B, Cand D.