vcaeng.comvcaeng.com/ftp/jacobs/from_vca/2015-09-28-60%design... · 1. the contractor shall verify...
TRANSCRIPT
1. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS ANDCONDITIONS AT THE SITE AND SHALL NOTIFY THE ARCHITECT OF DISCREPANCIES BETWEENTHE ACTUAL CONDITIONS AND INFORMATION SHOWN ON THE DRAWINGS BEFOREPROCEEDING WITH THE WORK. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL ANDPLUMBING DRAWINGS.
2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY THE SEOR OF ANYCONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND OTHER DRAWINGS; OR EXISTINGCONDITIONS NOT SHOWN OR DIFFERENT FROM THOSE SHOWN ON DRAWINGS PRIOR TOCOMMENCEMENT OF WORK. THE CONTRACTOR IS NOT TO ORDER MATERIAL ORCONSTRUCT ANY PORTION OF THE BUILDING THAT IS IN CONFLICT UNTIL THE CONFLICT ISRESOLVED WITH THE AFFECTED PARTIES.
3. CONTRACTOR SHALL CONSIDER THE PROJECT SPECIFICATIONS A PART OF THE CONTRACTDOCUMENTS. WHERE INFORMATION IS CONFLICTING, SPECIFIC DETAILS SHALL GOVERN OVERTYPICAL DETAILS WHICH SHALL GOVERN OVER THESE NOTES WHICH SHALL GOVERN OVERSPECIFICATIONS.
4. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST ARCHITECTURALDIMENSIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR,CONTACT THE ARCHITECT (ARCH) OR STRUCTURAL ENGINEER OF RECORD (SEOR). ALLDIMENSIONS RELATED TO EXISTING CONDITIONS SHALL BE FIELD VERIFIED BY THECONTRACTOR. DIMENSIONS ARE TO THE FACE OF STUDS, AND TO CENTERLINE OF COLUMNSUNO.
5. CONSTRUCTION MATERIALS SHALL NOT BE STORED, SPECIFICALLY NOT STACKED ONPOURED OR ERECTED FLOORS OR ROOF IN EXCESS OF 80% OF THE DESIGN LIVE LOAD. IT ISTHE GENERAL CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE SUB-CONTRACTORSARE INFORMED AND DO NOT VIOLATE THIS IMPORTANT REQUIREMENT. IMPACT SHALL BEAVOIDED WHEN PLACING MATERIALS ON ALREADY POURED OR ERECTED FLOORS OR ROOF.
6. OPENINGS, POCKETS, ETC., SHALL NOT BE PLACED IN SLABS, BEAMS, COLUMNS, WALLS, ETC.UNLESS SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS OR APPROVED IN WRITINGBY THE STRUCTURAL ENGINEER.
7. ALL ASTM SPECIFICATIONS NOTED ON THESE DRAWINGS SHALL BE OF THE LATESTREVISIONS.
8. DETAILS OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS THOSE SHOWN FORSIMILAR CONDITIONS. REFER TO THE TYPICAL DETAIL SHEETS FOR TYPICAL DETAILS OFCONSTRUCTION. TYPICAL DETAILS APPLY TO ALL CONSTRUCTION UNLESS SPECIFICALLYNOTED OR SHOWN OTHERWISE. WHERE CONDITIONS REQUIRE MODIFICATIONS OF A TYPICALDETAIL, THE CONTRACTOR SHALL SUBMIT MODIFIED DETAIL FOR APPROVAL BY THEENGINEER OF RECORD PRIOR TO FABRICATION AND INSTALLATION. DETAILS OFCONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS THOSE SHOWN FOR SIMILARCONSTRUCTION.
9. ALL WORK IS NEW (N) UNLESS INDICATED AS EXISTING (E).
10. SEE ARCHITECTURAL DRAWINGS FOR THE FOLLOWING:
- SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS, EXCEPT AS NOTED.- SIZE AND LOCATION OF ALL INTERIOR AND EXTERIOR NON-BEARING PARTITIONS.- SIZE AND LOCATION OF ALL CONCRETE CURBS, FLOOR DRAINS, SLOPES, DEPRESSED
AREAS, CHANGES IN LEVEL, CHAMFERS, GROOVES, INSERTS, ETC.- SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS EXCEPT AS SHOWN.- FLOOR AND ROOF FINISHES.
- STAIR FRAMING DETAILS. - DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
11. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR THE FOLLOWING:
- PIPE AND DUCT RUNS, SLEEVES, HANGERS, TRENCHES, PITS, WALL AND SLAB OPENINGS, ETC. EXCEPT AS SHOWN OR NOTED.
- ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALL AND SLABS.- CONCRETE INSERTS FOR ELECTRICAL OR PLUMBING FIXTURES.
12. ITEMS IN THE PROJECT SPECIFICATIONS, BUT NOT SHOWN ON THE DRAWINGS SHALL BECONSIDERED AS PART OF THE DRAWINGS.
13. REFER TO THE PROJECT SPECIFICATIONS FOR SHOP DRAWING REQUIREMENTS ANDSUBMITTALS.
14. EXISTING CONDITIONS
CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PERTINENT TO HIS WORK PRIOR TOMATERIAL FABRICATION AND/OR CONSTRUCTION. FIELD CONDITIONS DIFFERENT FROMTHOSE NOTED ON THE DRAWINGS SHALL BE PROMPTLY BROUGHT TO THE ATTENTION OFTHE CONTRACTING OFFICER. ITEMS TO BE FIELD VERIFIED INCLUDE BUT ARE NOT LIMITEDTO:
A. LOCATION, DIMENSIONS AND ELEVATIONS OF EXISTING STRUCTURES, STRUCTURAL ELEMENTS e.g., COLUMNS AND WALLS, EQUIPMENT AND UTILITIES, WHICH HAVE BEEN SHOWN AS REFERENCE POINTS ON THE DRAWINGS.
B. LOCATION, DIMENSIONS, ELEVATION, SIZE AND DETAIL OF THE EXISTING STRUCTURAL ELEMENTS WHICH WILL AFFECT NEW CONSTRUCTION.
C. HORIZONTAL AND VERTICAL CLEARANCES.
D. HORIZONTAL AND VERTICAL TIE-IN POINTS.
GENERAL
15. SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL DRAWINGSMAY BE CONSIDERED WITH MATERIALS HAVING EQUIVALENT OR GREATER CAPACITY ANDPERFORMANCE. CURRENT EVALUATION REPORTS AND PRODUCT INFORMATION SHALL BEPROVIDED TO THE STRUCTURAL ENGINEER DEMONSTRATING THE REQUIRED CAPACITYAND PERFORMANCE OF THE MATERIAL TO BE SUBSTITUTED. WRITTEN APPROVAL FROMTHE SEOR SHALL BE OBTAINED PRIOR TO THE SUBSTITUTION OF ANY MATERIAL SPECIFIEDON THE STRUCTURAL DOCUMENTS.
16. ALTERATION, REHABILITATION OR RECONSTRUCTION: TO BE IN ACCORDANCE WITH THEGOVERNING CODE. SHOULD ANY EXISTING CONDITIONS SUCH AS DETERIORATION OR NON-COMPLYING CONSTRUCTION BE DISCOVERED WHICH IS NOT COVERED BY THE CONTRACTDOCUMENTS WHEREIN THE FINISHED WORK WILL NOT COMPLY WITH THE GOVERNINGCODE, A CHANGE ORDER, OR A SEPARATE SET OF PLANS AND SPECIFICATIONS, DETAILINGAND SPECIFYING THE REQUIRED WORK SHALL BE SUBMITTED TO AND APPROVED BY THEENGINEER BEFORE PROCEEDING WITH THE WORK.
17. CONSTRUCTION LOADS: MATERIALS SHALL BE EVENLY DISTRIBUTED IF PLACED ONFRAMED FLOORS OR ROOFS. LOADS SHALL NOT EXCEED THE ALLOWABLE LOADING FORTHE SUPPORTING MEMBERS AND THEIR CONNECTIONS OR RESULT IN AN UNBALANCEDCONDITION.
18. STRUCTURAL PLANS INDICATE ONLY THE APPROXIMATE LOCATION OF MECHANICAL,ELECTRICAL AND OTHER EQUIPMENT, AS WELL AS THE RELATED AUXILIARY FRAMINGNECESSARY TO SUPPORT SUCH EQUIPMENT. THE FINAL POSITIONING OF THESE ITEMS ISDEPENDENT UPON THE EQUIPMENT PROVIDED. THE CONTRACTOR SHALL BERESPONSIBLE FOR COORDINATING WORK BETWEEN SUBCONTRACTORS AND CRAFTS INTHIS REGARD, AND PROVIDING NECESSARY DIMENSIONS IN A TIMELY MANNER TO ALLPARTIES INVOLVED.
19. PIPES, DUCTS, SLEEVES, CHASES, ETC. SHALL NOT BE PLACED IN SLABS, BEAMS, ORWALLS UNLESS SPECIFICALLY SHOWN OR NOTED NOR SHALL ANY STRUCTURAL MEMBERBE CUT FOR PIPES, DUCTS, ETC., UNLESS SPECIFICALLY SHOWN. OBTAIN PRIOR WRITTENAPPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC.
20. CONSTRUCTION METHODS AND PROJECT SAFETY: THE CONTRACT DRAWINGS ANDSPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE METHODS,PROCEDURES OR SEQUENCE OF CONSTRUCTION. THE CONTRACTOR SHALL TAKENECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF THE STRUCTUREAND ALL ADJACENT PROPERTIES DURING CONSTRUCTION. NEITHER THE GOVERNMENT,ARCHITECT, NOR ENGINEER WILL ENFORCE SAFETY MEASURES OR REGULATIONS. THECONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDINGSHORING AND BRACING, AND BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL,STATE AND FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULATIONS.
21. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS OFTHE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE OF CALIFORNIA, LATESTEDITION, AND ALL OSHA REQUIREMENTS AS THEY APPLY TO THIS PROJECT. THEARCHITECT, SEOR, AND THE OWNER DO NOT ACCEPT ANY RESPONSIBILITY FOR THECONTRACTOR'S FAILURE TO COMPLY WITH THESE REQUIREMENTS.
22. CORE DRILLS REQUIRED SHALL NOT CUT ANY REINFORCING. THE CONTRACTOR IS TOCOORDINATE WORK OF ALL TRADES TO ENSURE COMPLIANCE. ALL CORE DRILLS ARE TOBE PRESENTED TO THE IOR FOR VERIFICATION. THE IOR IS TO DOCUMENT CORESEXAMINED INDICATING AN ABSENCE OF REINFORCING.
(GENERAL NOTES CONT.)
THE PROJECT SHALL BE DESIGNED PRIMARILY UNDER UFC CRITERIA, AND INDUSTRYSTANDARDS AS MODIFIED BY THE UFC. THE FOLLOWING LATEST PUBLICATIONS SHALL BE USEDFOR THE DESIGN, FABRICATION, AND CONSTRUCTION OF STRUCTURAL ITEMS FOR THEPROJECT:
1. 2012 INTERNATIONAL BUILDING CODE, ANY OTHER REGULATING AGENCIES WHICH HAVEAUTHORITY OVER ANY PORTION OF THE WORK
2. UFC 3-301-01, STRUCTURAL ENGINEERING, 01 JUNE 2013 EDITION, INCLUDING CHANGE 1 15 MAY 2014.
3. UFC 3-310-04, SEISMIC DESIGN OF BUILDINGS, 01 JUNE 2013 EDITION
4. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, DATED 9FEBRUARY 2012, INCLUDING CHANGE 1, 1 OCTOBER 2013
5. UFC 4-211-01N, AIRCRAFT MAINTENANCE HANGARS: TYPE I, TYPE II, AND TYPE III, DATED 25OCTOBER 2004 INCLUDING CHANGE 3, 16 DECEMBER 2009
6. ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES INCLUDINGSUPPLEMENTS NO. 1 AND NO. 2, 2010 EDITION
7. AISC STEEL CONSTRUCTION MANUAL, 14TH EDITION
8. AISC 341-10, SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS, INCLUDINGSUPPLEMENT NO. 1, DATED 2005
9. AISC 360-10, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
10. ACI 318-11, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
11. TMS 402-11/ ACI 530-11/ ASCE 5-11, BUILDING CODE REQUIREMENTS FOR MASONRYSTRUCTURES
12. TMS 602-08/ ACI 530.1-08/ ASCE 6-08, SPECIFICATION FOR MASONRY STRUCTURES
13. AWS D1.1-10, STRUCTURAL WELDING CODE – STEEL
14. AWS D1.8-09, STRUCTURAL WELDING CODE – SEISMIC SUPPLEMENT
15. AWS D1.3-08, STRUCTURAL WELDING CODE – SHEET STEEL
16. AWS D1.4-11, STRUCTURAL WELDING CODE – REINFORCING STEEL
17. SDI CODE OF RECOMMENDED STANDARD PRACTICE FOR METAL DECK CONSTRUCTION
STRUCTURAL DESIGN CRITERIA
1. DEAD LOADS: AS CALCULATED
2. LIVE LOADS:A. ROOF 20 PSF (REDUCIBLE)
3. WIND LOAD:A. ULTIMATE BASIC WIND SPEED (3 SECOND GUST) = 110 MPHB. EXPOSURE: C
4. SEISMIC LOAD:SITE CLASS: D
SPECTRAL ACCELERATION: SS = 2.170gS1 = 0.909g
SITE COEFFICIENT: Fa = 1.00Fv = 1.5
DESIGN SPECTRAL ACCELERATION: SDS= 1.447SD1= 0.909
SEISMIC DESIGN CATEGORY: EIMPORTANCE FACTOR: I = 1.0RISK CATEGORY: II
FOR SPECIAL REINFORCED MASONRY SHEAR WALL SYSTEM,R = 5 Ω = 2 ½ Cd = 3 ½
DESIGN LOADS
1. NO SITE SPECIFIC SOILS REPORT WAS PROVIDED FOR THIS PROJECT. THE SOILS REPORTAND SOILS INFORMATION HEREIN IS BASED ON A SOILS REPORT FOR BLDG. PM 50 WHICH ISROUGHLY 0.50 MILES FROM PM 365 AND PM 553.
PREPARED BY: GEO-LOGIC ASSOCIATES 11415 WEST BERNARDO COURT, SUITE 200
SAN DIEGO, CA 92127REPORT NAME: P-500 TRITON MAINTENANCE TRAINING FACILITY
PM50 RENOVATIONNAVAL BASE VENTURA COUNTYPOINT MUGU, CALIFORNIA
DATED: OCTOBER 18, 2013PROJECT NO.2013-0131
GENERAL CONTRACTOR SHALL OBTAIN A COPY OF THE SOILS REPORT AND OBSERVE ALL RECOMMENDATIONS IN THE REPORT.
2. ALLOWABLE SOIL BEARING USED IN DESIGN:
A. DEAD LOADS + LIVE LOADS : 1500 PSF FOR SPREAD AND CONTINUOUS FOOTINGS SUPPORTED ON ENGINEERED FILL.
B. DEAD LOADS + LIVE LOADS + WIND OR SEISMIC : INCREASE ONE-THIRD ALLOWED
C. COEFFICIENT OF SLIDING RESISTANCE= 0.32
D. PASSIVE PRESSURE= 300 PCF
3. FOR GENERAL ADDITIONAL REQUIREMENTS OF EARTHWORK, SUBGRADE PREPARATION,ENGINEERED BACKFILL AND COMPACTION, OVEREXCAVATION, WATERPROOFING AND OTHERPERTINENT REQUIREMENTS AND INFORMATION, REFER TO FOUNDATION REPORT ANDSPECIFICATIONS.
4. SUBSURFACE SOIL PREPARATION:THE NEAR-SURFACE EXISTING ONSITE FILL SOILS MAY BE REUSED AS STRUCTURAL FILLSOILS, IF NECESSARY. PRIOR TO THE PLACEMENT OF NEW HARDSCAPE, WE RECOMMENDOVEREXCAVATING THE EXISTING SOILS BELOW AND ADJACENT TO HARDSCAPE TO AMINIMUM DEPTH OF 12 INCHES BELOW EXISTING OR PROPOSED SUBGRADE, WHICHEVER ISDEEPER. THE SOILS SHOULD BE RECOMPACTED TO A MINIMUM RELATIVE COMPACTION OF95 PERCENT (BASED ON ASTM D1557) BELOW STRUCTURAL ELEMENTS AND 90% BELOWFLATWORK.
NEW FOOTINGS CAN BE PLACED INTO EXISTING COMPETENT SOIL (WITHOUT RECOMPACTIONOF THE FOOTING BASE) PROVIDED THE BASE OF THE FOOTINGS IS OBSERVED BY THEGEOTECHNICAL CONSULTANT FOR COMPETENCY.
FOUNDATIONS
7. ALL OPEN FOUNDATION EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY A LICENSEDGEOTECHNICAL ENGINEER PRIOR TO POURING CONCRETE.
8. DO NOT PLACE FOOTING/GRADE BEAM REINFORCEMENT UNTIL SOIL ENGINEER OF RECORDMAKES AN OBSERVATION OF THE BEARING SURFACE.
9. SPREAD FOOTINGS ARE CENTERED UNDER WALLS AND COLUMNS, U.N.O.
10. FOOTING ELEVATIONS ARE NOTED ON THE PLANS AND DETAILS AND SHALL BE USED FORBIDDING. IN ANY CASE, FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL ORENGINEERED FILL, IN ACCORDANCE WITH THE SOIL REPORT AND DETAILS SHOWN.
11. FOOTINGS SHALL HAVE A MINIMUM OF 24" BELOW THE LOWEST ADJACENT FINISHED GRADEAND MINIMUM WIDTH OF 24" FOR CONTINUOUS AND ISOLATED SPREAD FOOTINGS,RESPECTIVELY.
12. ALL PIPES (WATER LINES, SEWER LINES, ETC.) AND CONDUITS RUNNING THROUGHWALLS/SLABS SHALL BE PROTECTED WITH 1/2" EXPANSION MATERIAL. CONTINUOUSFOOTINGS/GRADE BEAMS PERPENDICULAR TO PIPE RUNS SHALL BE EITHER LOWERED TOALLOW PIPES TO PASS THRU ABOVE SUCH FOOTINGS/GRADE BEAMS OR HAVE CONCRETEJACKET IF PIPES ARE LOW ENOUGH TO BE PLACED BELOW SUCH FOOTINGS/GRADE BEAMS.FOOTINGS/GRADE BEAMS PARALLEL TO PIPE RUNS SHALL BE LOWERED TO AVOID
SURCHARGE ONTO THE TRENCH EXCAVATIONS.
13. ALL WATER SHALL BE REMOVED FROM FOUNDATION AND PIT EXCAVATIONS PRIOR TO PLACING OF CONCRETE. CONTRACTOR IS RESPONSIBLE FOR THE GROUND WATER CONTROL SYSTEM DESIGN.
14. ALL FILLING, BACKFILLING, COMPACTING AND RECOMPACTING MUST HAVE A MINIMUMCOMPACTION PERCENTAGE OF THE MAXIMUM DENSITY AS SPECIFIED IN THE SOILS REPORT.
15. REFER TO CIVIL PLANS FOR LIMITS OF OVER EXCAVATIONS & GRADING PLANS.
16. REFER TO THE GEOTECHNICAL EVALUATION REPORT FOR SOIL CLASSIFICATION ANDRECOMMENDATIONS FOR PIT EXCAVATION AND SOIL RECOMPACTION AT EXISTING HANGAR.
17. TEN FOOT MAXIMUM INCREMENTS OF SLOT EXCAVATIONS ALONG THE EXISTING FOUNDATIONS AND ALL OTHER EXCAVATIONS SHALL BE PROPERLY BACKFILLED. BACKFILL FOR WALLS SHALL BE PERVIOUS MATERIAL ACCEPTABLE TO THE GEOTECHNICAL ENGINEER. DO NOT PLACE BACKFILL BEHIND WALLS BEFORE THEY HAVE ATTAINED THEIR DESIGN STRENGTH. SHORE AND PROTECT WALLS FROM LATERAL LOADS UNTIL SUPPORTING MEMBERS ARE IN PLACE AND HAVE DEVELOPED SPECIFIED STRENGTHS. FILL MATERIAL SHALL COMPLY WITH UFC REQUIREMENTS.
18. FOOTING BACKFILL AND UTILITY TRENCH BACKFILL WITHIN BUILDING AREA SHALL BEMECHANICALLY COMPACTED IN LAYERS WITH THE APPROVAL OF THE GEOTECHNICALENGINEER. FLOODING IS NOT PERMITTED.
19. ALL TRENCHES SHALL COMPLY WITH APPLICABLE OSHA REQUIREMENTS.
20. THE DESIGN OF ALL RETAINING WALLS AND SUBTERRANEAN BUILDING WALLS INDICATED ONTHESE DRAWINGS IS BASED ON DRAINED SOILS.
21. CONSTRUCTION JOINTS (CJ) AND SAWCUT (SC) JOINTS IN SLABS SHALL OCCUR WHERELOCATED ON PLANS AND DETAILS. CJ'S SHALL HAVE FORMED POUR STOPS. CONSTRUCTIONJOINTS IN WALLS AND FOOTINGS NEED NOT OCCUR AT THE SAME LOCATION, UNO.
22. SEE ARCHITECT'S PLANS FOR LOCATIONS OF SLAB SLOPES, DEPRESSIONS, CURBS, DRAINS,NON-STRUCTURAL PARTITIONS AND OTHER EMBEDDED ITEMS NOT SHOWN ON THESTRUCTURAL PLANS.
23. ALL GRADING, FOUNDATION FOOTINGS, AND DRAINAGE PLANS SHALL BE REVIEWED BY THEGEOTECHNICAL ENGINEER UPON SUBMITTAL. A CERTIFIED LETTER BY THE GEOTECHNICALENGINEER IS REQUESTED STATING THAT THE RECOMMENDATIONS CONTAINED WITHIN THESOILS REPORT HAVE BEEN INCORPORATED INTO THE PROJECT PLANS AND SPECIFICATIONSPRIOR TO CONSTRUCTION.
24. PRIOR TO THE CONTRACTOR REQUESTING A FOUNDATION INSPECTION, THE SOILSENGINEER SHALL ADVISE THE BUILDING OFFICIAL IN WRITING THAT:
A. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE SOILS REPORT.B. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND COMPACTED.C. THE FOUNDATION EXCAVATIONS COMPLY WITH THE INTENT OF THE SOILS REPORT.
4. CONT.ANY IMPORTED FILL SOILS SHOULD BE GRANULAR, HAVE AN EXPANSION INDEX OFLESS THAN 20 (PER IBC STANDARD 18-2), AND HAVE NO PARTICLES OVER 2 INCHES INMAXIMUM DIMENSION. PLACEMENT AND COMPACTION OF FILL SHOULD BE PERFORMEDIN GENERAL ACCORDANCE WITH THE CURRENT LOCAL GRADING ORDINANCES, U.S. NAVY SPECIFICATIONS, SOUND CONSTRUCTION PRACTICE, AND THE GREENBOOK SPECIFICATIONS.
A. ALL EXISTING UNDOCUMENTED FILL SHALL BE REMOVED AND RECOMPACTED. ALL TOPSOILS SHALL BE REMOVED AS REQUIRED BY THE GEOTECHNICAL ENGINEER.
B. GEOTECHNICAL ENGINEER SHALL BE RETAINED DURING THE OVEREXCAVATION PROCESS. THE ACTUAL DEPTH OF REMOVAL WILL BE DETERMINED DURING GRADING OPERATIONS.
C. OFFSITE FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT.
5. CONTRACTOR SHALL INVESTIGATE SITE DURING CLEARING AND EARTHWORK OPERATIONS FORFILLED EXCAVATIONS OR BURIED STRUCTURES SUCH AS CESSPOOLS, CISTERNS FOUNDATIONS,ETC. IF ANY SUCH STRUCTURES ARE FOUND, THE STRUCTURAL ENGINEER SHALL BE NOTIFIEDIMMEDIATELY.
6. EXCAVATIONS: LOCATE AND PROTECT UNDERGROUND OR CONCEALED CONDUIT, PLUMBING OROTHER UTILITIES WHERE NEW WORK IS BEING PERFORMED. WHEN OVERSIZE MATERIAL,CONCRETE, OR ASPHALT ENCOUNTERED, THESE MATERIAL SHOULD BE HAULED OFF SITE ANDDISPOSED IN ACCORDANCE WITH APPLICABLE CODES ADD REGULATIONS.
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
12" = 1'-0"
9/2
8/2
015 1
0:5
8:1
8 P
M
S-1.01
GE
NE
RA
L N
OT
ES
Designer Author Checker
xxxxxxxx
REINFORCING STEEL1. ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN CONFORMANCE WITH THE
"BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-11), AND THE"MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION" (LATESTED.) BY THE C.R.S.I., AS MODIFIED BY THE PROJECT DRAWINGS AND SPECIFICATIONS.
2. REINFORCING GRADES FOR CONCRETE OR MASONRY:A. ALL BARS EXCEPT THOSE TO BE WELDED............ ASTM A615, GRADE 60B. TIES AND STIRRUPS ................................................. ASTM A615, GRADE 60C. WELDED WIRE FABRIC ............................................. ASTM A185D. ALL BARS TO BE WELDED ........................................ ASTM A706, GRADE 60
3. MAINTAIN MINIMUM CONCRETE COVER FROM FACE OF CONCRETE TO EDGE OF ALLREINFORCEMENT AS FOLLOWS (UNO):
PROVIDE THE LARGEST COVER REQUIRED FOR ALL APPLICABLE CONDITIONS. WHERE #3STIRRUPS OR TIES ARE USED, ENSURE THAT THE COVER FOR LONGITUDINAL BARS ISADEQUATE.
4. REINFORCEMENT SHALL BE PLACED IN ACCORDANCE WITH THE CONCRETE REINFORCINGSTEEL INSTITUTE (CRSI) "MANUAL OF STANDARD PRACTICE". EACH REINFORCING BAR SHALLBE WIRED TO A CROSS BAR AT A MAXIMUM SPACING OF 24" OC. PROVIDE ALL ACCESSORIESNECESSARY TO SUPPORT REINFORCING IN POSITIONS SHOWN ON THE PLANS.
5. SPLICES IN CONTINUOUS REINFORCEMENT AS USED IN WALLS, WALL FOOTINGS, ETC., SHALLHAVE A CLASS "B" LAP (1'-6" MIN) AND THE SPLICES IN ADJACENT BARS SHALL BE NOT LESSTHAN 5'-0" APART. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. BARSMAY BE WIRED TOGETHER AT SPLICES OR LAPS EXCEPT FOR TOP REINFORCING OF BEAMSAND SLABS OR WHERE SPECIFICALLY DETAILED TO BE SEPARATED. WELDED WIRE FABRICSHALL BE LAPPED 12" MINIMUM.
6. REINFORCING SPLICES SHALL BE MADE ONLY WHERE INDICATED ON THE DRAWINGS.
7. ALL DOWELS, ANCHOR BOLTS AND OTHER HARDWARE TO BE SET IN CONCRETE SHALL BETIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO WET SETTING, STABBING,RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED DURINGPLACEMENT OF CONCRETE.
8. BEND ALL REINFORCING BARS COLD.
9. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST.
10. DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE ANDSPACING AS THE MAIN REINFORCING UNO.
11. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN THE FINAL INPLACE INSPECTION IS MADE.
12. CONTRACTOR TO PROVIDE CHAIRS, SPACERS, AND SAND PLATES AS REQUIRED TOMAINTAIN CONCRETE COVER. CHAIRS OR SPACERS SHALL BE NON-FERROUS OR PLASTICCOATED WHEN RESTING ON EXPOSED SURFACES.
CONDITION COVER
CONCRETE POURED AGAINST EARTH 3"
CONCRETE POURED IN FORMS ANDEXPOSED TO WEATHER OR EARTH
- #6 BARS AND LARGER 2"
- #5 BARS AND SMALLER 1 1/2"
INTERIOR COLUMNS AND BEAMS 1 1/2"
INTERIOR WALL FACES AND RAISED SLABS 1 1/2"
STRUCTURAL SLABS ON GRADE
- FROM BOTTOM OF SLAB 2"
- FROM TOP OF SLAB 1 1/2"
OTHER CONCRETE NOT EXPOSED TO WEATHEROR EARTH FOR #11 BARS AND SMALLER 3/4"
CONCRETE
6. LOCATE JOINTS NOT INDICATED TO LEAST IMPAIR STRENGTH AND APPEARANCE OFSTRUCTURE. LOCATE HORIZONTAL JOINTS IN CONCRETE ONLY WHERE THEY NORMALLYOCCUR OR WHERE INDICATED. LOCATE VERTICAL JOINTS IN MIDDLE THIRD OF SPANS OFSLABS, BEAMS OR GIRDERS, UNLESS A BEAM INTERSECTS A GIRDER AT MIDDLE LOCATION,IN WHICH CASE OFFSET JOINTS IN GIRDERS TWICE WIDTH OF BEAM.
7. STRUCTURAL CONCRETE SHALL MEET THE FOLLOWING DESIGN CRITERIA:
a. MAXIMUM DRY WEIGHT OF LIGHTWEIGHT CONCRETE SHALL BE 115 PCF, UNLESS APPROVEDBY SEOR.
b. SLUMP MEASURED PRIOR TO SUPERPLASTICIZER, WHERE OCCURS.
8. AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33 (HARDROCK).AGGREGATES IN LIGHT WEIGHT CONCRETE SHALL CONFORM TO ASTM C-330. EXCEPTIONSMAY BE USED ONLY WITH PERMISSION OF THE STRUCTURAL ENGINEER. USE A CARBONATECONCRETE AGGREGATE FOR ALL STRUCTURAL SLABS.
9. COMPRESSIVE STRENGTH TEST REPORTS SHALL BE SUBMITTED TO THE SEOR.
10. PORTLAND CEMENT SHALL BE TYPE II FOR ALL CONCRETE CONFORMING TO ASTM C150,LOW ALKALI. MILL TESTS WITH CERTIFICATES OF COMPLIANCE SHALL BE SUBMITTED.
11. FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS N OR F MAY BE USEDAS A PARTIAL SUBSTITUTION FOR PORTLAND CEMENT UP TO A MAXIMUM OF 15% TOTALCEMENTITIOUS MATERIALS BY WEIGHT IF THE MIX DESIGN IS PROPORTIONED PER ACI 318,SECTION 5.3.
12. CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94.
13. LEAN CONCRETE, WHERE SPECIFICALLY INDICATED, SHALL CONTAIN 2 SACKS OF CEMENT PERCUBIC YARD OF CONCRETE.
14. USE NON SHRINK GROUT UNDER BASE PLATES, SILL PLATES, ETC. (SEE SPECIFICATIONS)
15. DRYPACK OR NONSHRINK GROUT SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTHOF 5000 PSI, AND CONSIST OF MASTERFLOW 713, FIVE STAR GROUT, SIKA GROUT 212,EMBECO 636, OR APPROVED EQUAL. FOR THICK GROUT LAYERS FOLLOW MANUFACTURER'SGUIDELINES TO ATTAIN THE REQUIRED STRENGTH, WHICH MAY INCLUDE THE ADDITION OFPEA GRAVEL.
16. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIX SHALLBE CLEAN AND POTABLE.
17. FOR INTERIOR SLABS-ON-GRADE AND ALL OTHER SLABS RECEIVING ADHERED FLOORINGFINISHES (I.E., GLUED, ETC.), THE MAXIMUM W/C RATIO SHALL NOT EXCEED 0.46. CURINGCOMPOUNDS USED ON CONCRETE THAT IS TO RECIEVE FINISHES SHALL BE COMPATIBLE WITHTILE AND ADHESIVES OR GROUTS IN ACCORDANCE WITH MANUFACTURER'S DATA AND BEAPPROVED BEFORE USE.
18. MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST CONDITION FOR AMINIMUM OF 7 DAYS AFTER PLACEMENT UNLESS OTHERWISE ACCEPTED BY SEOR.
19. SEE ARCHITECTURAL DRAWINGS FOR WALL OPENINGS, WALL OFFSETS, CHAMFERS, KERFS,DRIPS AND FOR EXTENT OF DEPRESSIONS, RAMPS, ETC. PROVIDE SLEEVES FOR ALL PIPESTHROUGH CONCRETE WALLS AND FOOTINGS WHERE SHOWN ON THESE DRAWINGS. DO NOTCUT ANY REINFORCING WHICH MAY CONFLICT.CORING IS NOT PERMITTED WITHOUT PRIORAPPROVAL BY THE SEOR. NOTIFY THE STRUCTURAL ENGINEER IN ADVANCE OF CONDITIONSNOT SHOWN ON THE DRAWINGS.
20. CONDUIT OR PIPE SIZE (O.D.) SHALL NOT EXCEED 30 PERCENT OF SLAB THICKNESS ANDSHALL BE PLACED BETWEEN THE TOP AND BOTTOM REINFORCING UNLESS SPECIFICALLYDETAILED OTHERWISE. CONCENTRATIONS OF CONDUIT OR PIPES SHALL BE AVOIDED EXCEPTWHERE DETAILED OPENINGS ARE PROVIDED.
21. EXPOSED CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE FORMED WITH 3/4"CHAMFER, UNO.
22. ALL REINFORCING BARS, ANCHOR BOLTS AND OTHER CONCRETE INSERTS SHALL BE WELLSECURED IN POSITION PRIOR TO PLACING CONCRETE.
23. FOR FOUNDATIONS THAT ARE TO RECEIVE EITHER CONCRETE OR MASONRY WALLS:
A. ABRASIVELY CLEAN AND ROUGHEN TOPS OF FOOTINGS.
B. PROVIDE 1 1/2" X 3 1/2" X 1'-0" LONG KEYS AT 24" O.C. AT CENTERLINE OF WALLS UNO.
24. PROVIDE WATERSTOPS IN ALL BELOW-GRADE FOUNDATION WALL CONSTRUCTION JOINTS.
(CONCRETE CONT.)
1. ALL PHASES OF WORK PERTAINING TO THE CONCRETE CONSTRUCTION SHALL CONFORM TOTHE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-11) WITHMODIFICATIONS AS NOTED IN THE DRAWINGS OR SPECIFICATIONS.
2. CONCRETE MIX DESIGN AND TESTING SHALL MEET THE REQUIREMENTS OF THE BUILDINGCODE, AND SPECIFICATIONS. ALL CONCRETE MIXES SHALL BE DESIGNED BY A RECOGNIZEDTESTING LAB STAMPED AND SEALED BY A LICENSED CALIFORNIA CIVIL ENGINEER ANDSUBMITTED TO THE SEOR FOR REVIEW PRIOR TO CONCRETE PLACEMENT. STRUCTURALCONCRETE MIXES SHALL CONSIST OF 5 SACK MINIMUM, UNO.
3. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN WALLS) SO ASTO CAUSE SEGREGATION OF AGGREGATES. IN SUCH CASES, HOPPERS AND VERTICALCHUTES OR TRUNKS SHALL BE USED. CHUTES OR TRUNKS SHALL BE OF VARIABLELENGTHS SO THAT FREE UNCONFINED FALL OF CONCRETE SHALL NOT EXCEED SIX FEET. ASUFFICIENT NUMBER OF CHUTES OR TRUNKS SHALL BE USED TO ENSURE THE CONCRETEIS KEPT LEVEL AT ALL TIMES.
4. PLACEMENT OF CONCRETE SHALL CONFORM TO ACI STANDARD 301 AND PROJECTSPECIFICATIONS. SANDBLAST ALL CONCRETE SURFACES AGAINST WHICH CONCRETE IS TOBE PLACED.
5. CONSTRUCTION JOINTS SHALL BE ROUGHENED BY REMOVING THE ENTIRE SURFACE TOEXPOSE CLEAN AGGREGATE SOLIDLY EMBEDDED IN THE MORTAR MATRIX AND CLEANED,LEAVING NO LAITANCE, LOOSENED PARTICLES OR DAMAGED CONCRETE. SLUSH WITH ACOAT OF NEAT CEMENT BEFORE PLACING CONCRETE. SEE PLANS AND DETAILS FORLOCATION AND TYPE OF CONSTRUCTION JOINT. LOCATIONS OF ADDITIONAL CONSTRUCTIONJOINTS NOT SHOWN ON THESE PLANS SHALL BE SUBMITTED FOR APPROVAL BY THE EORPRIOR TO PLACING ANY CONCRETE.
MASONRY
1. CONCRETE MASONRY UNITS (CMU) SHALL BE GRADE "N" HOLLOW CORE, MEDIUM WEIGHTUNITS CONFORMING TO ASTM C-90, LATEST REVISION WITH A MAXIMUM SHRINKAGE OF .06%FROM THE SATURATED TO OVEN-DRY CONDITION. THE MINIMUM 28 DAY PRISM COMPRESSIVESTRENGTH OF MASONRY IN ACCORDANCE WITH THE BUILDING CODE:
2. MORTAR SHALL BE FRESHLY PREPARED AND UNIFORMLY MIXED AND IN THE FOLLOWINGRATIO BY VOLUME:
TYPE M OR S MORTAR: ONE PART PORTLAND CEMENT1/4 PARTS LIME PUTTY MAXIMUMDAMP LOOSE AGGREGATE:2-1/4 - (3) TIMES
3. MORTAR SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 1800 PSI AT 28 DAYS.
4. GROUT SHALL BE COMPOSED OF THE FOLLOWING RATIO BY VOLUME: ONE PART PORTLAND CEMENTTWO PARTS PEA GRAVELTHREE PARTS SAND AND SUFFICIENTWATER SHALL BE ADDED TO PRODUCE A CONSISTENCY FOR POURING WITHOUT SEGREGATION OF GROUT CONSTITUENTS.
5. SEE "REINFORCING STEEL SECTION" OF SPECIFICATIONS FOR ASTM SPECIFICATION OFREINFORCING STEEL.
6. VERTICAL REINFORCING SHALL BE FULL HEIGHT OF WALL AND SHALL BE BRACED AT 6'-8"MAXIMUM TO PREVENT MOVEMENT WHILE GROUTING.
7. HORIZONTAL REINFORCING SHALL BE IN BOND BEAM UNITS AND TIED SECURELY TO VERTICALREINFORCING.
8. DOWELS, ANCHORS, AND OTHER EMBEDDED ITEMS SHALL BE TIED SECURELY IN PLACE TOPREVENT MOVEMENT WHILE GROUTING. WET SETTING OR STABBING IS NOT ALLOWED.
9. VERTICAL CELLS TO BE FILLED SHALL HAVE VERTICAL ALIGNMENT; ANY OVERHANGINGMORTAR OR OTHER OBSTRUCTION OF DEBRIS SHALL BE REMOVED FROM THE INSIDES OFSUCH CELL WALLS.
10. PROVIDE 1/4" CLEARANCE FROM INSIDE FACE OF BLOCK MASONRY CELLS AND MINIMUM OFONE BAR DIAMETER, BUT NOT LESS THAN 3/4" CLEAR DISTANCE BETWEEN PARALLEL BARS.
11. MAXIMUM HEIGHT OF GROUT POUR SHALL BE AS PER IBC CHAPTER 21.
12. FOR GROUT POURS OVER 5 FEET, PROVIDE CLEANOUTS IN BOTTOM COURSE AT VERTICALREINFORCEMENT (32 INCHES MAX). SPECIAL INSPECTION IS REQUIRED.
13. GROUT SHALL BE PLACED IN A CONTINUOUS POUR IN GROUT LIFTS NOT EXCEEDING 6 FEET.
14. ALL GROUT SHALL BE CONSOLIDATED AT THE TIME OF POURING BY VIBRATING WITH A 3/4"VIBRATOR.
15. ALL CELLS SHALL BE GROUTED SOLID, UNLESS OTHERWISE NOTED
16. BLOCK SHALL BE PLACED IN RUNNING BOND AND SHALL BE 8"x8"x16" NOMINAL UNITS, UNO.
17. BLOCK MODULES/MORTAR JOINTS SHOWN ON THESE DRAWINGS ARE FOR PRESENTATIONPURPOSES ONLY, AND NOT INTENDED TO SUPERCEDE ARCHITECTURAL DESIGNREQUIREMENTS.
18. PROVIDE STD. 90° HOOK AT END OF ALL HORIZONTAL REINFORCMENT IN CMU WALLS.
19. NO COLD JOINTS ARE PERMITTED UNLESS SPECIFICALLY DETAILED.
20. FORM HORIZONTAL CONSTRUCTION JOINTS BY STOPPING THE GROUT POUR NOT LESS THAN1/2 INCH BELOW THE TOP OF THE UPPERMOST GROUTED UNIT. HORIZONTAL REINFORCEMENTSHALL BE FULLY EMBEDDED IN GROUT.
21. PROVIDE VERTICAL CONTROL JOINTS IN CMU WALLS AS SHOWN ON PLAN. UNLESS NOTEDOTHERWISE VERTICAL CONTROL JOINTS SHALL OCCUR AT 25'-0" O/C MAXIMUM ALONG WALLLENGTH, AT FOUNDATION STEPS, FLOOR OR ROOF JOINTS, WALL HEIGHT CHANGES, AND 24"MINIMUM PAST ONE SIDE OF OPENINGS GREATER THAN 6'-0" WIDE, UNO ON PLANS. CONTROLJOINTS SHALL BE LOCATED A MAXIMUM OF 1/2 THE MAXIMUM ON CENTER SPACING FROMWALL CORNERS AND INTERSECTIONS. TYPICAL JOINTS SHALL BE 3/8" UNLESS NOTEOTHERWISE.
METAL DECKING1. PROVIDE DESIGN, FABRICATION, AND ERECTION OF METAL DECK CONFORMING
TO THE STEEL DECK INSTITUTE'S "CODE OF RECOMMENDED STANDARD PRACTICEAND BASIC DESIGN SPECIFICATIONS".
2. DESIGN IS BASED ON THE STEEL DECK INSTITUTE DESIGN MANUAL FORCOMPOSITE DECKS, FORM DECKS, AND ROOF DECKS.
3. MATERIAL FOR METAL DECK SHALL HAVE A MIN YIELD STRENGTH OF 50 KSI ANDCONFORM TO ASTM A653-SS GRADE 33 WITH GALVANIZED G60 COATING COMPLYINGWITH ASTM A525.
4. SEE TYPICAL DETAILS FOR REINFORCING OF DECK AROUND OPENINGS. CONTRACTOR SHALLCOORDINATE SIZE AND LOCATIONS OF OPENINGS WITH THE VARIOUS TRADES. HOLES THATARE DIMENSIONED ON THE STRUCTURAL DRAWINGS SHALL BE THE RESPONSIBILITY OF THEDECK ERECTOR. NO LOADS SHALL BE HUNG FROM DECK WITHOUT APPROVAL OF SEOR.
5. METAL DECK FABRICATOR TO FURNISH SHOP DRAWINGS FOR STRUCTURAL ENGINEER'SREVIEW PRIOR TO FABRICATION. SHOP DRAWINGS SHALL INCLUDE TYPE OF DECK, LAYOUTOF DECK, THE SIZE AND LOCATION OF ANY OPENINGS OF WIDTH GREATER THAN 1'-0",WELDING PROCEDURE, SIDE LAP CONNECTIONS, TESTING PROGRAMS FOR WELDING,COATING MATERIAL AND ERECTION SEQUENCE.
6. WHEN SUBMITTING SHOP DRAWINGS, INCLUDE ICC-ESR NUMBER AND REPORT.
7. FLOOR AND ROOF DECK IS DESIGNED FOR UNSHORED CONSTRUCTION, UNO. MAINTAIN 3SPAN CONDITION WHEREVER POSSIBLE (2 SPAN MIN) EXCEPT AT STAIR LANDING AND WHERENOTED OTHERWISE ON PLANS.
8. PROVIDE 2" MINIMUM BEARING AT ALL SUPPORTS. END LAPS OF METAL DECK SHALL BE AMINIMUM OF 2" AND SHALL OCCUR ONLY OVER SUPPORTS. DECK SHALL BE LAID OUT SOTHAT A LOW FLUTE FALLS ON EACH PARALLEL SUPPORT.
9. INSTALL DECK BY WELDING. USE 3/4" DIAMETER PUDDLE WELDS OR WELDED STUDS TOSUPPORTS SPACED AS SHOWN ON CONSTRUCTION DRAWINGS. SPACING FOR TOP SEAM,SIDE SEAM, BUTTON PUNCH, OR PUNCHLOK CONNECTION SHALL BE IN ACCORDANCE WITHDRAWINGS. SEE TYPICAL METAL DECK DETAILS.
10. WHEN DECK IS SCHEDULED TO BE EXPOSED, DE-SLAG, CLEAN AND TOUCHED UP WELDSWITH A ZINC-RICH PRIMER.
11. ALTERNATES TO TYPE OF DECK AND FASTENING MAY BE USED WITH THE APPROVAL OF THESEOR. DECK PROPERTIES SHALL BE EQUAL TO OR GREATER THAN THOSE SHOWN ON THEPLANS. ANY DECK OR METHOD OF FASTENING SHALL HAVE AN EVALUATION REPORTAPPROVING THE DECK FOR THE APPLICATION.
12. STEEL COMPOSITE DECK SHALL BE FORMED WITH INTEGRAL LOCKING LUGS OREMBOSSMENTS TO PROVIDE A MECHANICAL LOCK BETWEEN THE STEEL DECK AND THECONCRETE SLAB TO PROVIDE A COMPOSITE UNIT. THICKNESS (GAUGE) AND DEPTH OFDECKING SHALL BE AS INDICATED ON THE DRAWINGS.
13. METAL DECK WITH CONCRETE FILL SHALL HAVE POSITIVE VENTING. DO NOT EMBED PIPES,SLEEVES, CONDUIT, ETC IN CONCRETE TOPPING, UNO.
LOCATION
FOUNDATIONS 3000 psi NWC 1 1/2" 0.50 4"
SLAB ON GRADE 3000 psi NWC 1" 0.45 4"
ALL OTHERSTRUCTURAL
CONCRETE NOT NOTEDABOVE
3000 psi NWC 1" 0.50 6"
MIN-28DAY COMPSTRENGTH
CONC
TYPE a
MAXAGGREGATE
SIZE
MAXW/C
RATIO
MAX
SLUMP b
STAIRS/STRUCT SLAB 4000 psi NWC 1" 0.45 4"
FILL OVER METAL DECK 3000 psi LWC 3/4" 0.46 6"
LOCATION f'mTYPE S
MORTARGROUT
MINIMUM 28 DAY COMPRESSIVE STRENGTH
ALL CMU UNO 1500 psi 1900 psi 2000 psi
HIGH-STRENGTH BOLT1. SEE STRUCTURAL STEEL NOTES THIS SHEET FOR ADDITIONAL INFORMATION.
2. JOINT ASSEMBLIES USING HIGH-STRENGTH BOLTS SHALL BE IN ACCORDANCE WITH THECURRENT EDITION OF THE "AISC SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325OR A490 BOLTS". SLIP-CRITICAL BOLTS SHALL BE USED FOR ALL "LATERAL FORCE RESISTINGSYSTEM" (LFRS) MEMBER STEEL TO STEEL CONNECTIONS.
3. ALL HIGH-STRENGTH BOLTS SHALL CONFORM TO ASTM A-325 OR ASTM A-490, NUTS SHALLCONFORM TO ASTM A-563 AND WASHERS SHALL CONFORM TO ASTM F-436.
4. PAINT SHALL NOT BE PERMITTED ON CONTACT SURFACES UNLESS NOTED OTHERWISE.CONTACT SURFACES OF BOLTED PARTS SHALL BE DESCALED AND FREE OF DIRT, OIL,BURRS, PITS, AND OTHER DEFECTS WHICH PREVENT SOLID SEATING OF PARTS.
5. SLIP-CRITICAL JOINT ASSEMBLIES SHALL BE FULLY PRE-TENSIONED BY TURN-OF-NUTTIGHTENING, CALIBRATED WRENCH TIGHTENING, INSTALLATION OF ALTERNATE DESIGNBOLTS OR BY DIRECT TENSION INDICATOR TIGHTENING.
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
12" = 1'-0"
9/2
8/2
015 1
0:5
8:1
9 P
M
S-1.02
GE
NE
RA
L N
OT
ES
Designer Author Checker
xxxxxxxx
STRUCTURAL STEEL AND MISC. METALS1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE
SPECIFICATIONS AND STANDARD OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION(AISC), AS CONTAINED IN THE LATEST EDITION OF "AISC MANUAL OF STEEL CONSTRUCTION".
2. ALL STEEL FABRICATION SHALL BE PERFORMED BY A LICENSED FABRICATOR.
3. ALL STRUCTURAL STEEL SHALL BE ERECTED PLUMB AND TRUE TO LINE. TEMPORARYBRACING SHALL BE INSTALLED AND SHALL BE LEFT IN PLACE UNTIL OTHER MEANS ISPROVIDED TO ADEQUATELY BRACE THE STRUCTURE.
4. PROVIDE THE FOLLOWING MATERIALS FOR STRUCTURAL STEEL (UNO):
5. EXCEPT AS OTHERWISE NOTED, ALL BOLTS SHALL BE HIGH STRENGTH BOLTS.
6. HIGH STRENGTH BOLTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONOF THE "AISC SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS".SLIP CRITICAL BOLTS (SC) SHALL BE USED FOR ALL "LATERAL FORCE RESISTING SYSTEM"(LFRS) MEMBER STEEL-TO-STEEL CONNECTIONS. TIGHTEN SLIP CRITICAL BOLTS USING ONEOF THE FOLLOWING: TWIST-OFF BOLTS, TENSION CONTROL CALIBRATED WRENCH ORDIRECT TENSION INDICATORS. HIGH STRENGTH BOLTS NOT IN THE LFRS MAY BE INSTALLEDHAND TIGHT.
7. ALL CONNECTIONS NOT SHOWN SHALL CONFORM TO THE "AISC MANUAL OF STEELCONSTRUCTION" AND SHALL BE SUBMITTED ON SHOP DRAWINGS FOR REVIEW BY SEORPRIOR TO FABRICATION.
8. THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS OF ALL STEEL FORENGINEER OF RECORD'S REVIEW BEFORE FABRICATION. SHOP DRAWINGS SHALL INCLUDEWELDING PROCEDURES, TESTING PROGRAMS FOR WELDING AND HIGH STRENGTHBOLTING, COATING MATERIAL, ERECTION SEQUENCE.
9. ANCHOR STUDS, SHEAR STUDS, AND DEFORMED ANCHORS.
A. SHALL BE MANUFACTURED BY NELSON STUD WELDING COMPANY OR APPROVED EQUAL, AND WELDED (IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS BY CERTIFIED WELDERS) SO AS TO FULLY DEVELOP THE TENSILE CAPACITY OF THE CONNECTOR.
B. HEADED STUDS (SHEAR AND ANCHOR) SHALL BE MADE OF MATERIAL CONFORMING TO (ASTM) A-108-07-T. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 50 HEADEDBOLT. U.N.O.
C. DEFORMED ANCHORS SHALL BE MADE OF MATERIAL CONFORMING TO THE CURRENT VERSION OF ASTM 496.
10. BOLTS WITH UPSET THREADS ARE NOT ALLOWED. USE THE APPROPRIATE NUT ANDWASHER TYPE FOR THE SPECIFIED BOLT. NUTS SHALL CONFORM TO ASTM A563, HOTFORGED.
11. ALL STEEL COLUMNS SHALL BE MILLED EACH END TO FIT FLUSH WITH BASE PLATE, CAP OREND TO END.
12. ALL STRUCTURAL STEEL AND MISCELLANEOUS STEEL PERMANENTLY EXPOSED TO THEELEMENTS SHALL BE HOT DIP GALVANIZED AFTER FABRICATION UNLESS A WEATHER PROOFCOATING IS SPECIFIED BY THE ARCHITECT UNO. STAINLESS AND WEATHERING STEELS AREEXCEPTED WHERE SPECIFIED.
13. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL COMPLY WITH AISCCODE OF STANDARD PRACTICE, SECTION 10.
14. SEE ARCHITECTURAL DRAWINGS FOR NAILER HOLES, WELDED STUDS OR OTHER ITEMS NOTSHOWN IN THESE DRAWINGS. WHERE STEEL IS EMBEDDED IN CONCRETE OR MASONRY,PROVIDE HOLES AS REQUIRED FOR PASSAGE OF CONTINUOUS REINFORCING BARS WHEREINDICATED ON DRAWINGS. DO NOT CUT HOLES IN STRUCTURAL STEEL WITHOUT PRIORAPPROVAL OF SEOR.
15. PLACE NON-SHRINK OR DRYPACK GROUT UNDER ALL BASE PLATES AND ALLOW TO CUREBEFORE APPLYING LOADS. SEE STRUCTURAL CONCRETE NOTES FOR GROUT INFORMATION.
16. ALL STEEL TUBES SHALL BE CAPPED AT ENDS.
17. UNLESS OTHERWISE NOTED ON DRAWINGS:
A. ALL BOLTS SHALL BE 3/4" DIAMETER.B. ALL BOLTED CONNECTIONS SHALL BE MADE WITH HIGH STRENGTH BOLTS EXCEPT
PURLIN, GIRT, AND DOOR FRAME CONNECTIONS WHICH MAY USE MACHINE BOLTS.C. ALL CONNECTIONS SHALL HAVE A MINIMUM OF TWO BOLTS OR EQUIVALENT WELD
CAPACITY.D. GUSSET PLATES SHALL BE 3/8" MIN. THICKNESS, UNLESS OTHERWISE NOTED.E. PROVIDE DIRECT TENSION-INDICATING (DTI) WASHERS AT ALL BOLTED CONNECTIONS.
STRUCTURAL STEEL GRADES:
A. ALL WIDE FLANGE SECTIONS ASTM A992
B. SQUARE OR RECTANGULAR HOLLOWSTRUCTURAL SECTIONS (HSS)
ASTM A500, GRADE
B (Fy=46 KSI)
C. ROUND HOLLOW STRUCTURALSECTIONS (HSS)
ASTM A500, GRADE B
(Fy=42 KSI)
D. PIPESASTM A53 TYPE E OR
S, GRADE B, (Fy=35 KSI)
E. PLATES, ANGLES, CHANNELS & TEES ASTM A36
F. MACHINE BOLTS (MB) ASTM A307
G. HIGH STRENGTH BOLTS (HSB) ASTM A325 TYPE N
H. WELDED HEADED STUDS ASTM A108
I. THREADED RODS FOR ANCHOR BOLTS ASTM F1554, GRADE 36
WELDING OF STRUCTURAL STEEL1. WELDING PROCEDURES, ELECTRODES AND WELDER QUALIFICATIONS SHALL CONFORM TO
THE STRUCTURAL WELDING CODE-STEEL, AMERICAN WELDING SOCIETY (AWS), D1.1 AND THEAISC "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS".
2. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AWS STANDARD QUALIFICATIONTESTS, AND SHALL BE CERTIFIED FOR THE WORK THEY ARE PERFORMING.
3. PROJECT WELDING SHALL BE PERFORMED ONLY IN ACCORDANCE WITH WELDINGPROCEDURE SPECIFICATIONS (WPS) SUBMITTED BY THE CONTRACTOR AND REVIEWED BYTHE SEOR AND PROJECT WELDING INSPECTOR. THE WPS SHALL BE IN ACCORDANCE WITHAWS D1.1-D1.4 CURRENT EDITION.
4. WELDING OF STRUCTURAL STEEL SHALL BE PERFORMED PER AWS D1.1 USING E70XXELECTRODES UNLESS OTHERWISED NOTED.
5. WELDING OF REINFORCING BARS SHALL BE PERFORMED PER AWS D1.4 USING E90XXELECTRODES.
6. WELDING OF METAL DECK AND LIGHT GAGE STEEL SHALL BE IN ACCORDANCE WITH AWS D1.3.
7. ALL FULL PENETRATION WELDS SHALL BE ULTRA-SONIC TESTED PER AWS D1.1.
8. ALL GROOVE OR BUTT WELDS SHALL BE COMPLETE PENETRATION WELDS. ALL EXPOSEDBUTT WELDS SHALL BE GROUND SMOOTH.
9. ALL EXPOSED WELDS ON ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALLCOMPLY WITH AISC CODE OF STANDARD PRACTICE, SECTION 10.
10. FIELD WELDS HAVE BEEN INDICATED WHERE THEY ARE EXPECTED TO OCCUR. THECONTRACTOR SHALL DETERMINE THE ACTUAL FIELD WELDING NECESSARY TO COMPLETETHE PROJECT AND INCLUDE ALL ASSOCIATED COSTS WITHIN THE BASE BID.
11. WHERE WELDS ARE DESIGNATED AS DEMAND CRITICAL, THEY SHALL BE MADE WITH A FILLERMETAL CAPABLE OF PROVIDING A MINIMUM CHARPY V-NOTCH (CVN) TOUGHNESS OF 20 FT-LBAT -20°F AND 40 FT-LB AT 70°F. SEE AISC 341-10 SECTION A3.4b FOR ADDITIONALREQUIREMENTS.
12. ALL WELDS WITHIN MEMBERS DESIGNATED AS PART OF THE LATERAL FORCE RESISTINGSYSTEM (LFRS) SHALL CONFORM TO THE DETAILING, MATERIALS, WORKMANSHIP, TESTING,AND INSPECTION REQUIREMENTS PER AWS D1.8.
13. CONTINUOUS INSPECTION IS REQUIRED FOR FIELD WELDING OF STRUCTURAL ANDREINFORCING STEEL.
ABADDLADJAFFAMSLAPPROXARCHARCH'TASTM
ANCHOR BOLTADDITIONALADJACENTABOVE FINISH FLOORABOVE MEAN SEA LEVELAPPROXIMATE(LY)ARCHITECTURALARCHITECTAM SOCIETY OF TESTINGMATERIALS
BBBCBETBLBLDGBMBOTBPBRGBRKTBSBSMTBVLBWBN
BACK TO BACKBOTTOM CHORDBETWEENBASE LINEBUILDINGBEAMBOTTOMBASE PLATEBEARINGBRACKETBOTH SIDESBASEMENTBEVELEDBOTH WAYSBOUNDARY NAILING
CCJCJPCL
CLRCMUCOLCONCCONSTCONTCONT'DCONXCUCY
COMPRESSIONCONSTRUCTION JOINTCOMPLETE JOINTPENETRATIONCENTERLINECLEAR OR CLEARANCECONCRETE MASONRY UNITCOLUMNCONCRETECONSTRUCTIONCONTINUOUSCONTINUEDCONNECTIONCUBICCUBIC YARD
DDBADBLDETLDIADIAGDIMDLDNDPDRWGDWL
DEPTHDEFORMED BAR ANCHORDOUBLEDETAILDIAMETERDIAGONALDIMENSIONDEAD LOADDOWNDAMP PROOFINGDRAWING(S)DOWEL
EEFEJELECELEV,ELEQEQUIPEWEXISTEXPEXTEN
EASTEACH FACEEXPANSION JOINTELECTRICALELEVATIONEQUALEQUIPMENTEACH WAYEXISTINGEXPANSIONEXTERIOREDGE NAILING
FABFDFDNFFFF ELFINFSFTFTG
FABRICATIONFLOOR DRAINFOUNDATIONFINISH FLOORFINISH FLOOR ELEVATIONFINISH(ED)FAR SIDEFOOTFOOTING
GAGALVGB
GAGE OR GAUGEGALVANIZEDGRADE BEAM
HEEHORIZHPHTHSHSS
HOOK EACH ENDHORIZONTALHIGH POINTHEIGHTHEADED STUDHOLLOW STEEL SECTION
IDIFININT
INSIDE DIAMETERINSIDE FACEINCHINTERIOR
JTJST
JOINTJOIST
KKOKSI
KIPS (1000 LBS)KNOCKOUTKIPS PER SQUARE INCH
LB,#LDLDGLHLHELLLLHLLVLONGLPLWLWCLW
POUNDDEVELOPMENT LENGTHLANDINGLEFT HANDLOW HYDROGEN ELECTRODELIVE LOADLONG LEG HORIZONTALLONG LEG VERTICALLONGITUDINALLOW POINTLONG WAYLIGHTWEIGHT CONCRETELONG WAY
MATLMAXMECHMEP
MEZZMFRMIDMINMISCMSMT
MATERIALMAXIMUMMECHANICALMECHANICAL, ELECTRICAL,PLUMBINGMEZZANINEMANUFACTURE(R)MIDDLEMINIMUMMISCELLANEOUSMIDDLE STRIPSTRUCTURAL TEE CUT FROMMISCELLANEOUS STEEL
N/ANFNICNONOMNSNTS
NOT APPLICABLENEAR FACENOT IN CONTRACTNUMBERNOMINALNEAR SIDENOT TO SCALE
OAOCODOFOPNGOPPOPP HNDOPT
OVERALLON CENTEROUTSIDE DIAMETEROUTSIDE FACEOPENINGOPPOSITEOPPOSITE HANDOPTIONAL
PCCPCFPERPPGPLPLUMBPREFABPRELIMPRMLDPROJPSFPTPVCPVT
PRECAST CONCRETEPOUNDS PER CUBIC FOOTPERPENDICULARPRESTRESSED GIRDERPLATEPLUMBINGPREFABRICATEDPRELIMINARYPREMOLDEDPROJECTIONPOUNDS PER SQUARE FOOTPOINTPOLYVINYL CHLORIDEPAVEMENT
RRADRDRE:REINFREMREQDREVRHRJRNDRORW
RIGHT, RISERRADIUSROOF DRAINREFERREINFORCING (-ED,-MENT)REMINDERREQUIREDREVISIONRIGHT HANDRUSTICATION JOINTROUNDROUGH OPENINGRETAINING WALL
SSC
SCHSECTSHTSIMSJSLSLRS
SPASPECSPLSQSSSTDSTIFFSTIRSTLSTRSTRUCTSWSYM
SOUTHSHEARCONNECTORSSCHEDULE(D)SECTIONSHEETSIMILARSAW JOINTSLOPESEISMIC-LOAD-RESISTINGSYSTEMSPACESPECIFICATION(S)SPECIALSQUARESTAINLESS STEELSTANDARDSTIFFENERSTIRRUPSTEELSTRUCTURALSTRUCTURALSHEAR WALLSYMMETRICAL
TT/T/CONCT/FDT/FTGT/SLABT&BTEMPTHKTHRDTOSTRDTRANSTSTSWTYP
TOP, TENSIONTOP OFTOP OF CONCRETETOP OF FLOOR DRAINTOP OF FOOTINGTOP OF SLABTOP AND BOTTOMTEMPERATURETHICKNESSTHREADEDTOP OF STEELTREAD(S)TRANSVERSESTRUCTURAL TUBINGTOP SEAM WELDTYPICAL
UNO
USGS
UNLESS NOTEDOTHERWISEUNITED STATESGEOLOGICAL SURVEY
VERTVIF
VERTICALVERIFY IN FIELD
WW/W/OWPWPJWT
WWF
WEST, WIDTH, WIDE FLANGEWITHWITHOUTWORK POINTWEAKENED PLANE JOINTWEIGHT, STRUCTURAL TEECUT FROM WIDE FLANGEBEAMWELDED WIRE FABRIC
YD YARD
STRUCTURAL ABBREVIATIONS(ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED IN THE DRAWINGS)
1. DESIGN, FABRICATION AND ERECTION OF COLD-FORMED STEEL FRAMING SHALLCONFORM TO THE SPECIFICATIONS AND STANDARD OF THE AMERICAN IRON AND STEELINSTITUTE (AISI), AS CONTAINED IN THE "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS", LATEST EDITION, INCLUDING ALL APPLICABLEAMENDMENTS.
FRAMING MEMBERS AND ACCESSORIES SHALL CONFORM TO:
A. 16 GAGE AND HEAVIER: ASTM A1003, GR. 50-GALVANIZED: ASTM A 653, GR. 50.
-PAINTED: ASTM A 570, GR. 50.B. 18 GAGE AND LIGHTER: ASTM A1003, GR. 33
-GALVANIZED: ASTM A 653, GR. 33.-PAINTED: ASTM A 570, GR. C
C. STEEL PLATES (3/16" AND THICKER): ASTM A36.
2. COLD FORMED JOISTS AND STUDS SHALL CONFORM TO THE SECTION PROPERTIESTABLE OF STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) ICBO ER-4943P.
3. STUD WALL FRAMING AND CONNECTIONS SHALL BE AS SHOWN IN "COLD-FORMEDSTEEL DETAILS" BY SSMA UNLESS SPECIFICALLY DETAILED.
4. SUBMIT COLD-FORMED STEEL FRAMING SHOP DRAWINGS AND SPECIFICATIONS TO THESEOR FOR REVIEW PRIOR TO FABRICATION.
5. ALL COLD-FORMED STEEL FRAMING SHALL BE ERECTED PLUMB AND TRUE TO LINE.TEMPORARY BRACING SHALL BE INSTALLED AND LEFT IN PLACE UNTIL OTHER MEANS ISPROVIDED TO ADEQUATELY BRACE THE STRUCTURE.
6. ALL COLD-FORMED STEEL FRAMING SHALL BE BRACED AS REQUIRED BY SECTION D3 OFTHE AISI SPECIFICATION.
7. SPLICE OF AXIALLY LOADED STUDS OR BRACES ARE NOT PERMITTED.
8. FRAMING COMPONENTS SHALL BE CUT SQUARELY OR TO THE EXACT ANGLE TO TIGHT FITTHE ABUTTING MEMBERS. MEMBERS SHALL BE HELD FIRMLY UNTIL PROPERLYFASTENED.
9. LATERAL BRIDGING SHALL BE INSTALLED AT 4'-0" O.C. MAX. U.N.O. AND IN A MANNER TOPROVIDE RESISTANCE TO BOTH MINOR AXIS BENDING AND ROTATION. BRIDGING ISREQUIRED WHEN WALL BOARD IS NOT PROVIDED ON EITHER SIDE.
10. FASTENING OF COMPONENTS SHALL BE BY WELDING OR SELF-DRILLING SCREWS, WIRETYING OF COMPONENTS IS NOT PERMITTED.
11. WELDING OF COLD FORMED FRAMES SHALL CONFORM TO AWS D1.1 AND D1.3. WELDINGSHALL BE PERFORMED BY WELDERS CERTIFIED FOR THE TYPE OF WELDS. WELDINGRODS SHALL CONFORM TO THE FOLLOWING:
A. 18 GAGE AND LIGHTER: E60XXB. 16 GAGE AND HEAVIER: E70XXC. LIGHT GAGE TO STRUCTURAL STEEL: E70XX LOW HYDROGEN
LIGHT GAGE STEEL FRAMING
12. TRACK SHALL BE UNPUNCHED WITH GAGE TO MATCH STUDFRAMING, U.N.O.
13. UTILITY PUNCHOUT HOLES IN STUDS SHALL BE LOCATEDAWAY FROM CONNECTIONS.
14. SCREWS SHALL BE WAFER HEAD SELF DRILLING/SELF-TAPPING STEEL SCREWS INSTALLED AND TIGHTENED INACCORDANCE WITH THE SCREW MANUFACTURERSSPECIFICATIONS. SCREWS SHALL PROVIDE A MINIMUMPENETRATION THROUGH THE JOINED MATERIALS OF NOTLESS THAN 3 EXPOSED THREADS.
(LIGHT GAGE STEEL FRAMINGCONT)
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
12" = 1'-0"
9/2
8/2
015 1
0:5
8:2
0 P
M
S-1.03
GE
NE
RA
L N
OT
ES
Designer Author Checker
xxxxxxxx
STRUCTURAL OBSERVATIONS1. STRUCTURAL OBSERVATIONS SHALL BE PERFORMED BY THE ENGINEER OF RECORD.
2. VISUAL OBSERVATIONS WILL BE PERFORMED AT THE DISCRETION OF THE OWNER, ARCHITECT,SEOR, AND AS REQUIRED BY THE BUILDING OFFICIAL IN ACCORDANCE WITH THE BUILDINGCODE.
3. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO NOTIFY THE STRUCTURALENGINEER AS TO WHEN EACH MAJOR PHASE OF CONSTRUCTION IS READY FOR OBSERVATIONA MINIMUM OF FIVE (5) WORKING DAYS IN ADVANCE. DELINQUENT NOTIFICATION MAY REQUIREDEMOLITION OF COVERING MATERIALS TO FACILITATE OBSERVATION.
4. THE STRUCTURAL OBSERVER SHALL PERFORM SITE VISITS AT THOSE STEPS IN THEPROGRESS OF THE WORK THAT ALLOW FOR CORRECTION OF DEFICIENCIES WITHOUTSUBSTANTIAL EFFORT OR UNCOVERING OF THE WORK INVOLVED. AT A MINIMUM, THEFOLLOWING ELEMENTS REQUIRE STRUCTURAL OBSERVATION:
5. THE STRUCTURAL OBSERVER SHALL PREPARE AN OBSERVATION REPORT DOCUMENTING ALLDEFICIENCIES OBSERVED. THE REPORT SHALL BE SENT TO THE CONTRACTOR FORCORRECTIVE ACTION.
6. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR THESPECIAL INSPECTIONS REQUIRED BY CHAPTER 17 OF THE IBC OR THESE DOCUMENTS.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT REINFORCEMENT, WELDS,CONNECTIONS, ETC. ARE VISIBLE FOR OBSERVATION WHEN THE SEOR IS ON SITE AND FORANY SCHEDULING DELAYS DUE TO NONCOMPLIANT ITEMS FOUND DURING THE OBSERVATION.
• FOUNDATION REBAR AND ANCHORS - PRIOR TO POUR OF CONCRETE• STRUCTURAL FRAMING - AFTER ERECTION AND PRIOR TO CLOSING IN• RAISED FLOOR SLABS AND REBAR - PRIOR TO POUR OF CONCRETE• COMPLETION OF THE STRUCTURAL SYSTEM
TABLE 1705.4.1
LEVEL 1 REQUIRED VERIFICATION AND INSPECTION OF MASONRY CONSTRUCTION
CONTINUOUS PERIODIC IBC SECTION
- ART. 1.5
COMPLIANCE WITH REQUIRED INSPECTIONPROVISIONS OF THE CONSTRUCTION DOCUMENTSAND THE APPROVED SUBMITTALS SHALL BEVERIFIED.
VERIFICATION OF f'm PRIOR TO CONSTRUCTIONEXCEPT WHERE SPECIFICALLY EXEMPTED BYTHIS CODE.
AS MASONRY CONSTRUCTION BEGINS, THEFOLLOWING SHALL BE VERIFIED TO ENSURECOMPLIANCE:
a. PROPORTIONS OF SITE-PREPARED MORTAR.
b. CONSTRUCTION OF MORTAR JOINTS.
c. GRADE AND SIZE OF PRESTRESSING TENDONSAND ANCHORAGES
d. LOCATION OF REINFORCEMENT, CONNECTORS,PRESTRESSING TENDONS AND ANCHORAGES.
e. PRESTRESSING TECHNIQUE
PRIOR TO GROUTING, THE FOLLOWING SHALL BEVERIFIED TO ENSURE COMPLIANCE:
a. GROUT SPACE IS CLEAN.
b. GRADE, TYPE, AND SIZE OF REINFORCEMENTAND ANCHOR BOLTS, AND PRESTRESSINGTENDONS AND ANCHORAGES
c. PLACEMENT OF REINFORCEMENT AND ANCHORBOLTS, AND PRESTRESSING TENDONS ANDANCHORAGES
d. PROPORTIONS OF SITE-PREPARED GROUT ANDPRESTRESSING GROUT FOR BONDED TENDONS
e. CONSTRUCTION OF MORTAR JOINTS.
DURING CONSTRUCTION THE INSPECTIONPROGRAM SHALL VERIFY:
a. SIZE AND LOCATION OF STRUCTURALELEMENTS.
b. TYPE, SIZE AND LOCATION OF ANCHORS,INCLUDING OTHER DETAILS OF ANCHORAGE OFMASONRY TO STRUCTURAL MEMBERS, FRAMESOR OTHER CONSTRUCTION.
c. WELDING OF REINFORCING BARS.
d. PREPARATION, CONSTRUCTION ANDPROTECTION OF MASONRY DURING COLDWEATHER (TEMPERATURE BELOW 40°F) OR HOTWEATHER (TEMPERATURE ABOVE 90°F).
e. APPLICATION AND MEASUREMENT OFPRESTRESSING FORCE
f. PLACEMENT OF GROUT AND PRESTRESSINGGROUT FOR BONDED TENDONS IS IN COMPLIANCE
OBSERVATION PREPARATION OF GROUTSPECIMENS, MORTAR SPECIMENS, AND/ORPRISMS
1.
2.
3.
4.
5.
6.
VERIFICATION AND INSPECTION
X
FREQUENCY OF INSPECTION REFERENCE FOR CRITERIA
TMS 402/ACI530/ASCE 5
TMS 602/ACI530.1/ASCE 6
- X
- X
- X
- X
- X
- X
-
- X
- X
-
-
-
-
-
-
-
-
-
-
-
- X -
-
-
-
-
-
-
-
SEC. 1.16
SEC. 1.16
SEC. 1.16.4.3,1.17.1
ART. 1.4B
ART. 2.1, 2.6A
ART. 3.3B
ART. 2.4B,2.6H
ART. 3.2D, 3.2F
ART. 3.2E,3.4, 3.6A
ART. 3.3F
- XSEC. 2104.3,
2104.4-
ART. 1.8C,1.8D
- X - - ART. 3.6B
- X - - ART. 3.4, 3.6A
- X - - ART. 3.6B
ART. 2.4, 3.4
- X - ART. 2.6B,2.4G.1.b
- -ART. 3.5,
3.6C
- X - -
ART. 1.4B.2.a.3,1.4B.2.b.3,1.4B.2.c.3,
1.4B.3, 1.4B.4
-
- - ART. 3.3B
-
X
- -
-
-X
TABLE 1705.6
REQUIRED VERIFICATION AND INSPECTION OF SOILS
VERIFICATION AND INSPECTION TASK CONTINUOUS DURING TASK LISTED PERIODIC DURING TASK LISTED
-VERIFY MATERIALS BELOW SHALLOW FOUNDATIONSARE ADEQUATE TO ACHIEVE THE DESIGN BEARINGCAPACITY.
VERIFY EXCAVATIONS ARE EXTENDED TO PROPERDEPTH AND HAVE REACHED PROPER MATERIAL.
PERFORM CLASSIFICATION AND TESTING OFCOMPACTED FILL MATERIALS.
VERIFY USE OF PROPER MATERIALS, DENSITIES ANDLIFT THICKNESSES DURING PLACEMENT ANDCOMPACTION OF COMPACTED FILL.
PRIOR TO PLACEMENT OF COMPACTED FILL,OBSERVE SUBGRADE AND VERIFY THAT SITE HASBEEN PREPARED PROPERLY.
1.
2.
3.
4.
5.
X
- X
- X
X -
- X
TABLE 1705.3
REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
CONTINUOUS PERIODIC REFERENCED STANDARD IBC REFERENCE
- ACI 318: 3.5, 7.1-7.7 1910.4
AWS D1.4ACI 318: 3.5.2
-
1904.2.1, 1910.2,1910.3
ACI 318: CH. 4, 5.2-5.4
ASTM C172ASTM C31
ACI 318: 5.6, 5.8
1910.10
1908.5, 1909.1ACI 318: 8.1.3, 21.2.8
1909.1ACI 318: 3.8.6, 8.1.3, 21.2.8
1910.6, 1910.7,1910.8
ACI 318: 5.9, 5.10
1910.9ACI 318: 5.11-5.13
INSPECTION OF REINFORCING STEEL, INCLUDINGPRESTRESSING TENDONS, AND PLACEMENT.
INSPECTION OF REINFORCING STEEL WELDING INACCORDANCE WITH TABLE 1705.2.2, ITEM 2b.
INSPECTION OF ANCHORS CAST IN CONCRETE WHEREALLOWABLE LOADS HAVE BEEN INCREASED ORWHERE STRENGTH DESIGN IS USED.
INSPECTION OF ANCHORS POST-INSTALLED INHARDENED CONCRETE MEMBERS.
VERIFYING USE OF REQUIRED DESIGN MIX.
AT THE TIME FRESH CONCRETE IS SAMPLED TOFABRICATE SPECIMENS FOR STRENGTH TESTS,PERFORM SLUMP AND AIR CONTENT TESTS, ANDDETERMINE THE TEMPERATURE OF THE CONCRETE.
INSPECTION OF CONCRETE AND SHOTCRETEPLACEMENT FOR PROPER APPLICATION TECHNIQUES.
INSPECTION FOR MAINTENANCE OF SPECIFIEDCURING TEMPERATURE AND TECHNIQUES.
INSPECT FORMWORK FOR SHAPE, LOCATION ANDDIMENSIONS OF THE CONCRETE MEMBER BEINGFORMED.
1.
2.
3.
4.
5.
6.
7.
8.
9.
VERIFICATION AND INSPECTION
-
-
-
-
X
X
-
X
X
X
X
X
-
-
X
ACI 318: 6.1.1 -- X
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
12" = 1'-0"
9/2
8/2
015 1
0:5
8:2
1 P
M
S-1.04
GE
NE
RA
L N
OT
ES
Designer Author Checker
xxxxxxxx
STRUCTURAL TEST AND INSPECTION PROGRAM (IBC CHAP. 17)
AISC 360-10 TABLE N5.4-1INSPECTION TASKS PRIOR TO WELDING
INSPECTION TASK PRIOR TO WELDING QC QA
WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE
MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
(1)
P P
PP
(2)
AISC 360-10 TABLE N5.4-3INSPECTION TASKS AFTER WELDING
INSPECTION TASK AFTER WELDING QC QA
WELDS CLEANED
SIZE, LENGTH, AND LOCATION OF WELDS
WELDS MEET VISUAL ACCEPTANCE CRITERIA- CRACK PROHIBITION- WELD/BASE METAL FUSION- CRATER CROSS SECTION- WELD PROFILES- WELD SIZE- UNDERCUT- POROSITY
ARC STRIKES
K-AREA
BACKING REMOVED AND TABS REMOVED (IF REQUIRED)
DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER
(1)
O O
PP
P P
PP
PP
PP
PP
AISC 360-10 TABLE N5.6-2INSPECTION TASKS DURING BOLTING
INSPECTION TASK DURING BOLTING QC QA
FASTENER ASSEMBLIES OF SUITABLE CONDITION, PLACED IN ALL HOLES ANDWASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED
JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THEPRETENSIONING OPERATION
(1)
O O
OO
AISC 360-10 TABLE N5.6-3INSPECTION TASKS AFTER BOLTING
INSPECTION TASK AFTER BOLTING QC QA
DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS
(1)
P P
(1) REFER TO AISC 360-10 CHAPTER N FOR ADDTIONAL INFORMATION.(2) P=PERFORM THESE TASKS FOR EACH WELDED JOINT OR MEMBER.(3) O=OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS.AISC 360-10 TABLE N5.4-2
INSPECTION TASKS DURING WELDING
INSPECTION TASK DURING WELDING QC QA
USE OF QUALITY WELDERS
CONTROL AND HANDLING OF WELDING CONSUMABLES- PACKING- EXPOSURE CONTROL
NO WELDING OVER CRACKED TACK WELDS
WPS FOLLOWED- SETTINGS ON WELDING EQUIPMENT- TRAVEL SPEED- SELECTED WELDING MATERIALS- SHIELDING CAS TYPE/FLOW RATE- PREHEAT APPLIED- INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.)- PROPER POSITION (F, V, H, OH)
(1)
O O
OO
(3)
O O
O O
AISC 360-10 TABLE N5.6-1INSPECTION TASKS PRIOR TO BOLTING
INSPECTION TASK PRIOR TO BOLTING QC QA
MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS
PER-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNELOBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED
(1)
O P
OP
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
12" = 1'-0"
9/2
8/2
015 1
0:5
8:2
1 P
M
S-1.05
GE
NE
RA
L N
OT
ES
Designer Author Checker
xxxxxxxx
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1" = 60'-0"
9/2
8/2
015 1
0:5
8:2
3 P
M
S-2.00
OV
ER
ALL S
ITE
PLA
N
Designer Author Checker
xxxxxxxx0 60' 120' 180'
SCALE: 1" = 60'-0"
NORTH
PM553 CONTROLLED FACILITY 3SEE SHEET S-2.02 PM553 SECURED CONTROLLED FACILITY 2
SEE SHEET S-2.03
PM365 CONTROLLED FACILITY 1SEE SHEET S-2.01
SCALE: N.T.S.SCALE: 1" = 60'-0" S-2.00S-3.01
SITE PLAN (FOR REFERENCE ONLY) 1
HANGER 365HANGER 553
PM365SEE SHEET S-2.04A
PM365SEE SHEET S-2.04B
D
E
G
H
41
1S-3.01
3S-3.01
2S-3.01
5S-3.03
4S-3.03
1S-3.03
2S-3.03
3S-3.03
1
S-9.15
1
S-9.15
1
S-9.15
2
S-9.15
2
S-9.15
6" CONC SLABW/ #5 @ 16" O/C
EA WAY W/ 2"CLEAN SANDOVER 10 MILMOISTURE
BARRIER OVER4" CLEANGRAVEL
WF-2
WF
-2
WF-2WF
-2W
F-2
.5
WF-2
WF-2.5
4
S-9.15
S S
G1'
TYP@PIT
REINF. (E) CMUWALL WITH (N)SHOTCRETE(THKNESSTBD)
D'
C'
E1'
E2'
74' -
5"
5' -
3"
20' -
11"
9"
5' -
10"
8' -
0"
16' -
2"
13' -
1"
4' -
5"
40'
TYP.3" SEISMIC JOINT
-4'-0''
35' - 6"
HSS6X6X1/2HSS6X6X1/2
6S-3.03
7S-3.03
D'1
2'-0' 'THK FTG
FOR CMUWALL
HSS6X6X1/2
HSS6X6X1/2
D
E
G
H
41
W16X26
W16X26
W16X26
W16X26
W16X26
W16X26
W16X26
W16X26
W16X26
C12X25
C12X
25
C12X25
C12X25
W16X
40
C12X25
C12X
25
C12X
25
C12X25
C12X25
C12X
25
C12X25
C12X
25
W16X
40
EXTENT OF ROOF
5S-3.03
4S-3.03
1S-3.03
2S-3.03
3S-3.03
D1
G1'
D'
C'
E1'
E2'
40'
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
5
S-9.12
5
S-9.12
2
S-9.17
TYP3" SEISMIC JOINT
W16X
40
6S-3.03
7S-3.03
D'1
W12X
22
W12X
22
AHU-1OP.WT.=1500 LBS
W12X22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
W12X
22
D1
C12X
25
W12X
22
D'
E1'
E2'C12X25
C12X25
C12X25
W16X26
BELOWHSS6X6X1/2
BELOWHSS6X6X1/2
W12X22D'1W12X22
BELOWHSS6X6X1/2
BELOWHSS6X6X1/2
4S-3.03
1S-3.03
2S-3.03
D2
C12X25
D'
E1'
E2'
CURTAINWALL BYOTHERS
CURTAINWALL BYOTHERS
CONTHSS6X6X1/2
CONTHSS6X6X1/2
6S-3.03
7S-3.03
D'1
W16X26
W12X
22
W12X22
CONTHSS6X6X1/2
CONTHSS6X6X1/2
W12X22
NORTH
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
SHEET NOTES
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:2
5 P
M
S-2.01
PM
365 C
ON
TR
OLLE
D F
AC
ILIT
Y 1
Designer Author Checker
xxxxxxxx
SCALE: 1/8" = 1'-0" S-2.01S-3.01
1FOUNDATION PLANSCALE: 1/8" = 1'-0" S-2.01S-3.01
2ROOF FRAMING PLAN
SCALE: 1/8" = 1'-0" S-2.01S-3.01
4FRAMING @ ELEVATOR ROOF
SCALE: 1/8" = 1'-0" S-2.01S-3.01
3
FRAMING @ ELEVATORLANDING
1. FOR GENERAL NOTES, SEE S-1.01 SERIES.
2. FOR TYPICAL DETAIL, SEE SHEETS S-9.01 TO S-9.13.
3. SEE ARCHITECTURAL DRAWINGS FOR CONCRETE SLAB ON GRADE ELEVATIONS,DEPRESSIONS, SLOPES, OPENINGS, CURBS, DRAINS, TRENCHES, PADS, SLABEDGE LOCATIONS; OVERALL WALL DIMENSIONS, AND LOCATION OF OPENINGS NOTINDICATED ON STRUCTURAL DRAWINGS.
4. PIPES, CONDUITS OR SLEEVES SHALL NOT BE EMBEDDED IN SPREAD FOOTINGSOR WITHIN THE TOP OR BOTTOM THIRD OF CONTINOUS FOOTINGS UNLESSSPECIFICALLY DETAILED IN STRUCTURAL DRAWINGS.
5. SEE SHEETS S-9.09 TO S-9.11 FOR INTERIOR METAL STUD WALL CONSTRUCTION.
6. INDICATES STEEL DECK DIRECTION. REFER TO DETAIL 1/S-9.06 FOR MORE INFORMATION.
7. S S INDICATES STEPPED FOOTING. REFER TO DETAIL 7/S-9.02 FOR MORE INFORMATION.
WALL FOOTING SCHEDULE
MARKDIMENSION REINFORCEMENT
WIDTH DEPTH LONG SHORT
WF-2 2'-0" 24"
WF-2.5 2'-6" 24"
#5 @ 12" O/C #5 @ 12" O/C
#5 @ 12" O/C #5 @ 12" O/C
8. INDICATES 8" CMU WALL, U.N.O.
9. FOR TYPICAL BEAM TO BEAM CONNECTIONS, SEE DETAILS ON DETAIL 1/S-9.12.
10. FOR ROOF SLOPES, REFER TO ARCH DRAWINGS.
G
J
3S-3.02
2S-3.02
1S-3.02
41
7" 58' - 1" 1' - 11"
1
S-9.15
1
S-9.15
1
S-9.15
5
S-9.15
(E) CMU WALL
6" CONC SLAB W/ #5 @16" O/C EA WAY W/ 2"CLEAN SAND OVER 10
MIL MOISTURE BARRIEROVER 4" CLEAN GRAVEL
WF
-2
SF-6.5
WF-2
H'
G'
0' 3'
TY
P
3"
SE
ISM
IC J
OIN
T
1' -
2"
32' -
2"
6"
33' -
10"
(E) WALL TO INFILL
60' - 7"W
F-2
G
J3
S-3.02
2S-3.02
1S-3.02
41
W16X
26
W16X
26
W16X
26
W16X
45
W16X
26
W16X
26
W16X
26
C12X
25
W16X40W16X40
C12X
25
C12X25
BELOWHSS6X4X1/2
D1
W12X22
W12X22
W12X22
W12X22
W12X22
W12X22
H'
G'
0' 3'
EXTENT OF ROOF
5
S-9.12
5
S-9.12
2
S-9.17
TY
P.
3"
SE
ISM
IC J
OIN
T
AHU-6OP.WT.=1500 LBS
W12X22
W12X22 W12X22
W12X22
W12X22 W12X22 W12X22 W12X22 W12X22 W12X22 W12X22 W12X22
0 8' 16' 24'2' 4'
GRAPHIC SCALE: 1/8" = 1'-0"
0 8' 16' 24'2' 4'
GRAPHIC SCALE: 1/8" = 1'-0"
NORTH
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
SHEET NOTES
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:2
6 P
M
S-2.02
PM
553 C
ON
TR
OLLE
D F
AC
ILIT
Y 1
Designer Author Checker
xxxxxxxx
SHEET NOTES
SCALE: 1/8" = 1'-0" S-2.02S-3.01
FOUNDATION PLAN 1
SCALE: 1/8" = 1'-0" S-2.02S-3.01
ROOF FRAMING PLAN 2
WALL FOOTING SCHEDULE
MARKDIMENSION REINFORCEMENT
WIDTH DEPTH LONG SHORT
WF-2 2'-0" 24"
WF-2.5 2'-6" 24"
#5 @ 12" O/C #5 @ 12" O/C
#5 @ 12" O/C #5 @ 12" O/C
SPREAD FOOTING SCHEDULE
MARKDIMENSION REINFORCEMENT
WIDTH DEPTH LONG SHORT
SF-6.5 6'-6" 24" #5 @ 12" O/C #5 @ 12" O/C
1. FOR GENERAL NOTES, SEE S-1.01 SERIES.
2. FOR TYPICAL DETAIL, SEE SHEETS S-9.01 TO S-9.13.
3. SEE ARCHITECTURAL DRAWINGS FOR CONCRETE SLAB ON GRADE ELEVATIONS,DEPRESSIONS, SLOPES, OPENINGS, CURBS, DRAINS, TRENCHES, PADS, SLABEDGE LOCATIONS; OVERALL WALL DIMENSIONS, AND LOCATION OF OPENINGSOT INDICATED ON STRUCTURAL DRAWINGS.
4. PIPES, CONDUITS OR SLEEVES SHALL NOT BE EMBEDDED IN SPREAD FOOTINGSOR WITHIN THE TOP OR BOTTOM THIRD OF CONTINOUS FOOTINGS UNLESSSPECIFICALLY DETAILED IN STRUCTURAL DRAWINGS.
5. SEE SHEETS S-9.09 TO S-9.11 FOR INTERIOR METAL STUD WALL CONSTRUCTION.
6. INDICATES STEEL DECK DIRECTION. REFER TO DETAIL 1/S-9.06 FOR MORE INFORMATION.
7. S S INDICATES STEPPED FOOTING. REFER TO DETAIL 7/S-9.02 FOR MOREINFORMATION.
8. INDICATES 8" CMU WALL, U.N.O.
9. FOR TYPICAL BEAM TO BEAM CONNECTIONS, SEE DETAILS ON DETAIL 1/S-9.12.
10. FOR ROOF SLOPES, REFER TO ARCH DRAWINGS.
G
J6
S-3.02
5S-3.02
4S-3.02
31 34
1
S-9.15
1
S-9.15
1
S-9.15
5
S-9.15
(E) CMU WALL
6" CONC SLAB W/ #5 @16" O/C EA WAY W/ 2"CLEAN SAND OVER 10
MIL MOISTURE BARRIEROVER 4" CLEAN GRAVEL
WF
-2
WF
-2
WF-2
SF-6.5
H'
G'
TY
P
3"
SE
ISM
IC J
OIN
T
31' 34A'
1' -
2"
32' -
2"
6"
33' -
10"
1' - 9" 58' - 3"1' - 0"
61' - 0"
(E) WALL TO INFILL
(E) WALL TO INFILL
G
J6
S-3.02
5S-3.02
4S-3.02
31 34
W16X40 W16X40
C12X
25
W16X
26
W16X
26
W16X
26
W16X
40
W16X
26
W16X
26
W16X
26
C12X
25
C12X25
BELOWHSS6X4X1/2
D1
H'
G'
EXTENT OF ROOF
W12X22
W12X22
W12X22
W12X22
W12X22
W12X22
5
S-9.12
2
S-9.17
5
S-9.12
TY
P3"
SE
ISM
IC J
OIN
T
31' 34A'
AHU-7OP.WT.=1500 LBS
W12X22 W12X22
W12X22W12X22
W12X22 W12X22 W12X22 W12X22 W12X22 W12X22 W12X22 W12X22
NORTH
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
SHEET NOTES
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:2
6 P
M
S-2.03
PM
553 S
EC
UR
ED
CO
NT
RO
LLE
D F
AC
ILIT
Y 2
Designer Author Checker
xxxxxxxx
SCALE: 1/8" = 1'-0" S-2.03S-3.01
FOUNDATION PLAN 1
SCALE: 1/8" = 1'-0" S-2.03S-3.01
ROOF FRAMING PLAN 2
WALL FOOTING SCHEDULE
MARKDIMENSION REINFORCEMENT
WIDTH DEPTH LONG SHORT
WF-2 2'-0" 24"
WF-2.5 2'-6" 24''
#5 @ 12" O/C #5 @ 12" O/C
#5 @ 12" O/C #5 @ 12" O/C
SPREAD FOOTING SCHEDULE
MARKDIMENSION REINFORCEMENT
WIDTH DEPTH LONG SHORT
SF-6.5 6'-6" 24" #5 @ 12" O/C #5 @ 12" O/C
1. FOR GENERAL NOTES, SEE S-1.01 SERIES.
2. FOR TYPICAL DETAIL, SEE SHEETS S-9.01 TO S-9.13.
3. SEE ARCHITECTURAL DRAWINGS FOR CONCRETE SLAB ON GRADE ELEVATIONS,DEPRESSIONS, SLOPES, OPENINGS, CURBS, DRAINS, TRENCHES, PADS, SLABEDGE LOCATIONS; OVERALL WALL DIMENSIONS, AND LOCATION OF OPENINGS NOTINDICATED ON STRUCTURAL DRAWINGS.
4. PIPES, CONDUITS OR SLEEVES SHALL NOT BE EMBEDDED IN SPREAD FOOTINGSOR WITHIN THE TOP OR BOTTOM THIRD OF CONTINOUS FOOTINGS UNLESSSPECIFICALLY DETAILED IN STRUCTURAL DRAWINGS.
5. SEE SHEETS S-9.09 TO S-9.11 FOR INTERIOR METAL STUD WALL CONSTRUCTION.
6. INDICATES STEEL DECK DIRECTION. REFER TO DETAIL 1/S-9.06 FOR MORE INFORMATION.
7. S S INDICATES STEPPED FOOTING. REFER TO DETAIL 7/S-9.02 FOR MORE INFORMATION.
8. INDICATES 8" CMU WALL, U.N.O.
9. FOR TYPICAL BEAM TO BEAM CONNECTIONS, SEE DETAILS ON DETAIL 1/S-9.12.
10. FOR ROOF SLOPES, REFER TO ARCH DRAWINGS.
A
C
B
D
E
F
G
H
J
K
A2
E9
A1
4441 42 43 45 46 47 48 49 50 51 52 53
2S-3.01
20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0"
220' - 0"
1S-3.05
1S-3.06
H'
6S-3.03
7S-3.03
(N) 11'' THK CONC SLAB ON GRADEW/ #5@12''O/C E.W TOP+BOTTYP.
6
S-9.15
(N)CHAINLINK FENCE
TYP
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1" = 10'-0"
9/2
8/2
015 1
0:5
8:2
7 P
M
S-2.04A
HA
NG
ER
365 -
CR
AN
E
Designer Author Checker
xxxxxxxx
SCALE: 1" = 10'-0" S-2.04AS-3.01
1FOUNDATION PLAN
MA
TC
H L
INE
: S
EE
SH
EE
T S
-2.0
4B
A
C
B
D
E
F
G
A1
54 55 56 57 58 59 60 61 62 63 64 65
1S-3.07
(N) 11'' THK CONC SLAB ON GRADEW/ #5@12''O/C E.W TOP+BOTTYP.
6
S-9.15
(N)CHAINLINK FENCE
TYP
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1" = 10'-0"
9/2
8/2
015 1
0:5
8:2
7 P
M
S-2.04B
HA
NG
ER
365 -
CR
AN
E
Designer Author Checker
xxxxxxxx
SCALE: 1" = 10'-0" S-2.04BS-3.01
1FOUNDATION PLAN
MA
TC
H L
INE
: S
EE
SH
EE
T S
-2.0
4A
A
C
B
D
E
F
G
H
J
K
A2
E9
A1
4441 42 43 45 46 47 48 49 50 51 52 53
1
S-3.04
(E)
W33X
141
(E)
W33X
141
(E)
W33X
141
(E)
W33X
141
(E)
W33X
141
(E)
W33X
141
(E) O.W. STEEL JOIST (TYP)
RUNWAY TRACKFOR CRANE
RUNWAY TRACKFOR CRANE
(E) O.W. STEEL JOIST(TYP)
(E)
WF
BE
AM
(TY
P)
RUNWAY TRACKLATERAL BRACING
TYP
RUNWAY TRACKLATERAL BRACING
TYP
RETROFIT COLAT EA. W33X141REFER TODETAILFORADDT'L INFOTYP@ GRIDE-43,E-45,E-47,E-49E-51,E-53,E-55,E-57E-59,E-61,E-63
1
S-3.04
(E)MTLDECK
(N)OPENING
AHU-3OP.WT.=5800 LBS
(N)OPENING
(N)OPENING
(N)OPENING
AHU-2OP.WT.=3200 LBS
RETROFIT (E) BEAMTO SUPPORT(N) MECH EQUIPMENT
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1" = 10'-0"
9/2
8/2
015 1
0:5
8:2
9 P
M
S-2.05A
HA
NG
ER
365 -
CR
AN
E
Designer Author Checker
xxxxxxxxSCALE: N.T.S.SCALE: 1" = 10'-0" S-2.05AS-3.01
ROOF FRAMING PLAN 1
MA
TC
H L
INE
: S
EE
SH
EE
T S
-2.0
5B
A
C
B
D
E
F
G
H
J
K
A1
54 55 56 57 58 59 60 61 62 63 64 65
(E)
W33X
141
(E)
W33X
141
(E)
W33X
141
(E)
W33X
141
(E)
W33X
141
(E) O.W. STEEL JOIST (TYP)
(E) O.W. STEEL JOIST(TYP)
(E)
WF
BE
AM
(TY
P)
RUNWAY TRACKLATERAL BRACING
TYP
RUNWAY TRACKLATERAL BRACING
TYP
RUNWAY TRACKFOR CRANE
RUNWAY TRACKFOR CRANE
RETROFIT COLAT EA. W33X141REFER TODETAILFORADDT'L INFOTYP@ GRIDE-43,E-45,E-47,E-49E-51,E-53,E-55,E-57E-59,E-61,E-63
1
S-3.04
(E)MTLDECK
AHU-4OP.WT.=5800 LBS
(N)OPENING
(N)OPENING
(N)OPENING
(N)OPENING
(N)OPENING
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1" = 10'-0"
9/2
8/2
015 1
0:5
8:3
2 P
M
S-2.05B
HA
NG
ER
365 -
CR
AN
E
Designer Author Checker
SCALE: N.T.S.SCALE: 1" = 10'-0" S-2.05BS-3.01
ROOF FRAMING PLAN 1
MA
TC
H L
INE
: S
EE
SH
EE
T S
-2.0
5A
F.F.0' - 0"
41
2A
S-9.04
2C
S-9.04
2C
S-9.04
(V)
(H)
40'
F.F.0' - 0"
2A
S-9.04
2C
S-9.042C
S-9.04
(V)
(H)
G1'C' D'1
F.F.0' - 0"
41
2A
S-9.04
2B
S-9.04
2B
S-9.04
2C
S-9.042C
S-9.04
2C
S-9.042C
S-9.04
2C
S-9.04
(V)
(H)
40'
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:3
3 P
M
S-3.01
WA
LL E
LE
VA
TIO
NS
Designer Author Checker
xxxxxxxx
GENERAL NOTES KEY NOTES
SCALE: 1/8" = 1'-0" S-3.01S-2.01
1ELEVATION ASCALE: 1/8" = 1'-0" S-3.01S-2.01
ELEVATION C 3
SCALE: 1/8" = 1'-0" S-3.01S-2.01
2ELEVATION B
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
F.F.0' - 0"
2A
S-9.04
2C
S-9.04
2C
S-9.04
(V)
(H)
0' 3'
F.F.0' - 0"
2A
S-9.04
2C
S-9.04
2C
S-9.04
2B
S-9.04
2C
S-9.042C
S-9.04
(V)
(H)
H' G'
F.F.0' - 0"
2C
S-9.04
2A
S-9.04
2C
S-9.04(V)
(H)
H'G'
F.F.0' - 0"
2A
S-9.04
2C
S-9.04
2C
S-9.04
(V)
(H)
31' 34A'
F.F.0' - 0"
2A
S-9.04
2C
S-9.04
2C
S-9.04
(V)
(H)
H' G'
F.F.0' - 0"
2A
S-9.04
2C
S-9.04 2C
S-9.04
2C
S-9.04
2C
S-9.04
2B
S-9.04
(V)
(H)
H'G'
0 8' 16' 24'2' 4'
GRAPHIC SCALE: 1/8" = 1'-0"
0 8' 16' 24'2' 4'
GRAPHIC SCALE: 1/8" = 1'-0"
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
SHEET NOTES
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:3
3 P
M
S-3.02
WA
LL E
LE
VA
TIO
NS
Designer Author Checker
xxxxxxxx
SCALE: 1/8" = 1'-0" S-3.02S-2.02
ELEVATION F 3
SCALE: 1/8" = 1'-0" S-3.02S-2.02
2ELEVATION ESCALE: 1/8" = 1'-0" S-3.02S-2.02
1ELEVATION D
KEY NOTES
SCALE: 1/8" = 1'-0" S-3.02S-2.03
ELEVATION I 6
SCALE: 1/8" = 1'-0" S-3.02S-2.03
5ELEVATION HSCALE: 1/8" = 1'-0" S-3.02S-2.03
4ELEVATION G
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
MEZZANINE LEVEL17' - 11 1/2"
F.F.0' - 0"
41
2C
S-9.04
2C
S-9.04
2A
S-9.04
#4 @ 24"O/C (H)
#6 @ 8"O/C (V)
#5 @ 8"O/C (V)
8" SOLID GROUT CMU
MEZZANINE LEVEL17' - 11 1/2"
F.F.0' - 0"
41
2C
S-9.04
2C
S-9.04
2A
S-9.04
#4 @ 24"O/C (H)
#5 @ 8"O/C (V)
8" SOLID GROUT CMU
MEZZANINE LEVEL17' - 11 1/2"
F.F.0' - 0"
41
2C
S-9.04
2C
S-9.04
2B
S-9.04
2D
S-9.04
2A
S-9.04
2B
S-9.04
2B
S-9.04
2C
S-9.04
2C
S-9.04
(V)(H)
2D
S-9.04
MEZZANINE LEVEL17' - 11 1/2"
F.F.0' - 0"
2C
S-9.04
2C
S-9.04
2A
S-9.04
#4 @ 24"O/C (H)
#6 @ 8"O/C (V)
#5 @ 8"O/C (V)
8" SOLID GROUT CMU
D'1
EFG E9
MEZZANINE LEVEL17' - 11 1/2"
F.F.0' - 0"
(E) CMU WALL
(N) OPENING
(N) OPENING
D'E1'E2'
REINF. (E) CMU WALL WITH(N) SHOTCRETE(THICKNESS TBD)
D'1
F.F.0' - 0"
41
HSS6X6X1/2 HSS6X6X1/2
W16X26
HSS4X4X3/8 BRACE
HSS4X4X3/8 BRACE
W16X26
E9
F.F.0' - 0"
E1' E2'
HSS6X6X1/2
W12X22
HSS6X6X1/2
W12X22
HSS4X4X3/8 BRACE
HSS4X4X3/8 BRACE
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:3
4 P
M
S-3.03
WA
LL E
LE
VA
TIO
NS
Designer Author Checker
xxxxxxxx
SCALE: 1/8" = 1'-0" S-3.03S-2.01
2ELEVATION KSCALE: 1/8" = 1'-0" S-3.03S-2.01
4ELEVATION MSCALE: 1/8" = 1'-0" S-3.03S-2.01
1ELEVATION JSCALE: 1/8" = 1'-0" S-3.03S-2.01
3ELEVATION L
SCALE: 1/8" = 1'-0" S-3.03S-2.01
5ELEVATION N - (E) CMU WALL
GENERAL NOTES KEY NOTES
8''SOLID GROUT CMUH: #4 @ 24''O.C.V: #5 @ 8''O.C.
SCALE: 1/8" = 1'-0" S-3.03S-2.01
6ELEVATION J1SCALE: 1/8" = 1'-0" S-3.03S-2.01
7ELEVATION J2
A E GA1
T.O. STEEL43' - 0 1/2"
F.F.0' - 0"
T.O. STEEL MEZZ17' - 7"
(E) W12X65
(E) W14X87
(E) W33X141
(E) W14X87
W14X84
3' - 0" 80' - 0" 30' - 0"
113' - 0"
(E)WF BM
LATERAL BRACETBD
RUNWAY TRACK BMTBD
1
S-9.17
(E)W14X53
LATERAL BRACETBD
RUNWAY TRACK BMTBD
D'C' E1' E2'
G'
SEE
(E)
FOR STIFFENING
D'1
VERTICAL RODTBD
VERTICAL RODTBD
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:3
5 P
M
S-3.04
CR
AN
E E
LE
VA
TIO
N
Designer Author Checker
xxxxxxxx
SCALE: N.T.S.SCALE: 1/8" = 1'-0" S-3.04S-2.05A
CRANE ELEVATION 1
MEZZANINE LEVEL17' - 11 1/2"
F.F.0' - 0"
4441 42 43 45 46 47 481
S-3.04
MA
TC
H L
INE
: S
EE
2/S
-3.0
6 F
OR
CO
NT
INU
AT
ION
(N) OPENING
(E) TO INFILL
(E) TO INFILL
(N) OPENING
(N) OPENING
(E) TO INFILL
(N) OPENING
(E) TO INFILL
(E) OPENING
(E) OPENING
(E) OPENING
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
SHEET NOTES
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:3
5 P
M
S-3.05
INT
ER
IOR
WA
LL E
LE
VA
TIO
NS
- H
AN
GE
R 3
65
Designer Author Checker
xxxxxxxx
SCALE: 1/8" = 1'-0" S-3.05S-2.01
1ELEVATION 1 NEW
1. FOR GENERAL NOTES, SEE S-1.01 SERIES.
2. FOR TYPICAL SAW CUT REFER TO DETAIL 1/S-9.14.
3. REFER TO DETAIL 3/S-9.14 AT (E) WALL TO BE INFILLED.
4. REFER TO DETAIL 5/S-9.14 AT (N) OPENINGS IN WALL.
MEZZANINE LEVEL17' - 11 1/2"
F.F.0' - 0"
49 50 51 52 53 54 55 56 57
MA
TC
H L
INE
: S
EE
2/S
-3.0
5 F
OR
CO
NT
INU
AT
ION
MA
TC
H L
INE
: S
EE
2/S
-3.0
7 F
OR
CO
NT
INU
AT
ION
(E) TO INFILL
(E) TO INFILL
(E) TO INFILL (E) TO INFILL
(E) TO INFILL
(N) OPENING (N) OPENING (N) OPENING(N) OPENING
(E) OPENING
(E) OPENING (E) OPENING
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
SHEET NOTES
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:3
6 P
M
S-3.06
INT
ER
IOR
WA
LL E
LE
VA
TIO
NS
- H
AN
GE
R 3
65
Designer Author Checker
xxxxxxxx
SCALE: 1/8" = 1'-0" S-3.06S-2.04A
1ELEVATION 2 NEW
1. FOR GENERAL NOTES, SEE S-1.01 SERIES.
2. FOR TYPICAL SAW CUT REFER TO DETAIL 1/S-9.14.
3. REFER TO DETAIL 3/S-9.14 AT (E) WALL TO BE INFILLED.
4. REFER TO DETAIL 5/S-9.14 AT (N) OPENINGS IN WALL.
MEZZANINE LEVEL17' - 11 1/2"
F.F.0' - 0"
57 58 59 60 61 62 63 64 65
MA
TC
H L
INE
: S
EE
2/S
-3.0
6 F
OR
CO
NT
INU
AT
ION
(N) OPENING
(E) TO INFILL
(N) OPENING
(E) TO INFILL (E) TO INFILL
(E) TO INFILL
(E) TO INFILL
(N) OPENING (N) OPENING
(N) OPENING
(N) OPENING
(E) OPENING
(E) OPENING
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
SHEET NOTES
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1/8" = 1'-0"
9/2
8/2
015 1
0:5
8:3
6 P
M
S-3.07
INT
ER
IOR
WA
LL E
LE
VA
TIO
NS
- H
AN
GE
R 3
65
Designer Author Checker
xxxxxxxx
SCALE: 1/8" = 1'-0" S-3.07S-2.04B
1ELEVATION 3 NEW
1. FOR GENERAL NOTES, SEE S-1.01 SERIES.
2. FOR TYPICAL SAW CUT REFER TO DETAIL 1/S-9.14.
3. REFER TO DETAIL 3/S-9.14 AT (E) WALL TO BE INFILLED.
4. REFER TO DETAIL 5/S-9.14 AT (N) OPENINGS IN WALL.
b
b
90° BEND
135° BEND
INSIDE BEND DIAM D, TYP
90°HOOK
A
B
C
NOTES:1. L - HOOK DEVELOPMENT LENGTH.2. L - DEVELOPMENT LENGTH.3. SEE BUILDING CODE AND ACI LATEST VERSION FOR ALLREQUIREMENTS NOT NOTED.4. FOR LIGHTWEIGHT CONCRETE MULTIPLY L AND L VALUES SHOWNBY 1.3.5. "TOP" BARS ARE HORIZONTAL WITH MORE THAN 12'' OF FRESHCONCRETE CAST BELOWBARS. ALL OTHER BARS ARE "BOT" BARS.6. STD HOOK L DOES NOT ACCOUNT FOR THE EFFECT OF TIES.CONFINED HOOK L MAYBE USE WHERE ACI 318-11 12.5.3b-c APPLIES.7. VALUES SHOWN ABOVE ARE FOR GRADE 60 (FY=60KSI)REINFORCEMENT.8. SPLICE LENGTHS SHOWN ARE FOR CLEAR SPACING NOT LESS THAN2D CONCRETE COVER NOT LESS THAN D9. FOR EPOXY-COATED REINFOCEMENT, SEE BUILDING CODE.
dh
d
dh d
dh
dh
b b
FINISHED BENDDIAMETER D IN
INCHESBAR SIZE
#9
#10
#11
#14
#18
9 1/2"
10 3/4"
12"
24"
18 1/4"
STANDARD HOOKS
b
b
INSIDE BENDDIAM D, TYP
90° HOOK
180° "U" HOOK
b JOINT FACE @STD HOOK,OUTSIDE OF TIE@ CONFINED HOOK
2" MIN SIDECOVER IS REQ'D
FOR STRAIGHTBAR EMBED,USE
DEVELOPMENTLENGTH Ld
D
135° &90° HOOK
ECLOSED TIE / HOOP
FROUND HOOP
CONTACTSPLICE
NON-CONTACTSPLICE
1:6 MAX SHOPBEND ALLOWED
GLAP SPLICES
BARSIZE
#3
#4
#5
#6
#7
#8
#9
#10
#11
6
8
10
12
14
16
18
20
22
l7
22
28
33
48
55
62
70
78
22
29
36
43
63
72
81
91
101
BOT
22
29
36
43
63
72
81
91
101
28
37
131
118
105
93
81
56
47
6
7
9
10
12
14
15
17
19
15
19
24
29
42
48
54
61
67 87
79
70
62
54
37
31
25
1919
25
31
37
54
62
70
79
87
24
32
40
48
70
80
91
102
113
6
6
9
8
11
12
14
15
17
13
17
22
26
37
43
48
54
60
17
22
28
33
49
55
63
70
78
17
22
28
33
49
55
63
70
78
22
29
36
43
63
72
81
91
101
#3
#4
#5
#6
#7
#8
#9
#10
#11
#3
#4
#5
#6
#7
#8
#9
#10
#11
STD
HOOK
Ldh (in)
DEVELOPMENT
LENGTH L d (in)
6
6
8
10
11
13
14
16
18
6
6
7
8
10
11
12
14
15
6
6
7
6
9
10
11
12
14
CONFINED HOOKLdh (in)
CLASS B LAP
SPLICE Ld (in)
BOTTOP TOP
STD & CONFINED HOOKS
(NON-STIRRUP/TIE)
CAP / CROSS TIE
BEAM TIE / STIRRUP
STIRRUP & TIE HOOKS
(#8 & SMALLER ONLY)
b
b
b
b
dh
b
d
b
3000 P
SI N
WC
4000 P
SI N
WC
5000 P
SI N
WC
DIM
EN
SIO
NIN
G
DE
TA
ILIN
G
d
12DB(>#5)6DB (#3,#4,#5)
6d (#6,#7,)4d (#3,#4,)
6d
d
2 1/2''MIN4d MIN&
COVER2''MIN
MIN
12d
d
LENGTH L
MIN HOOK EMBED
8d (#9,#10)6d (#8&SMALLER)
d
6''M
AX
1/2
''MIN
CLASS B TYP
SPLICE LENGTH L
WELD LENGTH PERSCHEDULE
WELD LENGTHPER SCHEDULE
STEEL PLATE
AFLARE V-GROOVE WELD
BSINGLE V-GROOVE WELDWITH SPLIT PIPE BACKING
CHIP OR GRIND ROOTTO SOUND METALBEFORE WELDING
SECOND SIDE
C DOUBLE BEVEL GROOVE WELD
DFLARE BEVEL GROOVE WELD
NOTES:1. WELDING SALL BE WITH LOW HYDROGEN ELECTRODESE90XX AND SHALL CONFORM TO AWS-D1.4.2. ALL WELDING SHALL BE SBJECT TO CONTINUOUSINSPECTION3. REINFORCING BARS TO BE WELDED SHALL MEET THEREQUIREMENT OF ASTM A706.
#3 3"
#4
#6
#5
#7
#8
#9
#10
4"
5"
6"
3"
3"
5"
6"
MIN WELD LENGTH
WELD SCHEDULE
BAR SIZE
ECOMPLETE JOINT PENETRATION
GROOVE WELD
60°
1/8''.
1/8''MAX
D
1/1
6''.
1/8''. 1/8
''.
45°
MA
X1/8
''.
1/8''.
D
1/8''.
1/8
''.
45°
1/16''.
D/5
D
CJP
CJP
THIS CORNER DETAIL FORBARS OF NEAR CENTER OFWALL OR FT'G
SINGLE LAYER - BARS ONE FACE OR CENTER
DOUBLE LAYER (2) #5
TYPICAL CONTINUOUSBAR SPLICE. U.N.O. ONPLANS OR DETAILS
#5 MIN
#5 MIN#5 MIN
(2) #5
2"CLR
B
18''MIN
CLASS"B"12D
2''C
LR
2''C
LR
12D
2''C
LR
12DB
B
12D
B
18''MIN
CLASS"B"
12D 12DBB
6''.
18''MIN
CLASS"B"
SLAB UNDERLAYMENTPER PLAN ANDGEOTECHNICAL REPORT
FINISH GRADEPER ARCH
SEE ARCH FORNOSING AND TREADDETAILING,TYP
CONC SOGPER PLAN
#4 @ 12"OC CONT, TYP
TYP SLAB REINFPER PLAN
#4 @ 12"OC
(2) #4 CONT
T.O.CONC(SEE ARCH)
T.O. CONC(SEE ARCH)
SEEARCH
T
2'0''LAP
3''C
LR
10"
1' M
IN
AR
CH
SE
E
T M
IN
EQ
EQ
TRENCH DRAINSEE PLAN FOR
LENGTH
#3 @ 18"OCW/ 18" HKS
(2) #4 TOP & BOTAS SHOWN
1' - 0"
AS REQD
2"
PLA
NP
ER
5''TYP
3''C
LR
5"
1'0
''MA
XP
ER
AR
CH
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:3
7 P
M
S-9.01
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.01
TYP REINF DETAILS AND DEVELOPMENT LENGTHS 1
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.01
TYP REINFORCING BAR WELDING 2
SCALE: 3/4" = 1'-0" S-9.01
3REINF BAR SPLICES WALLS, CONT FTGS
SCALE: 3/4" = 1'-0" S-9.01
4STAIR ON GRADE
SCALE: 3/4" = 1'-0" S-9.01
5TYP TRENCH DRAIN
#4 DOWEL W/ STD HOOK @18"OC OR #3 DOWEL DRILL&EPOXY @ 12"OC
OPTIONAL CONST JT, CLEAN& MOISTEN PRIOR TO POUR
CONC SLABW/ 4" MIN
THICKNESS
OPTIONAL CONST JT ROUGHENTO 1/4" AMPLITUDE MOISTEN
PRIOR TO POUR
#3 DOWELS @ 12"OCAROUND PERIMETER W/STANDARD HOOK ORDRILL & EPOXY W/ HILTIHY-150 (ICC ER #5193)EMBED AS SHOWN
(2) #4 CONT
3/4" CHAMFERUNO
ANCHORAGEPER PLAN
#3 @ 12"OC EA WAYW/ OPTIONALLAP SPLICE
HOUSEKEEPING PAD
BCONCRETE CURB
A
CONC SLABW/ 4" MIN
THICKNESS
3/4" CHAMFER UNO
T
8''MAX
4''MIN
1' M
AX
4''
MIN
3''M
IN2/3
T
PER PLAN
TYP1 1/2'' CLR
TY
P1 1
/2''
CLR
6''M
AX
4 BOLT 03''MIN OR
3''M
IN2/3
T
#4 BARS @ 12"OC EWAT TOP & BOTTOM
1/2" NEOPRENE FILLEREXP JOINT ALL AROUNDAT INTERIOR CONDITION
EXTERIOR SLABOR FINISHGRADE
CONC EQUIPMENT PAD
INTERIOR SLAB ON GRADE
ANCHORAGEPER PLAN
DIMENTION PER PLAN
(4) BOLT DIA4''CLR MIN OR
1'6
''MIN
8''
MIN
UN
OC
UR
B A
S R
EQ
D
2''
CLR
NOTE:THE CONTRACTOR MAY SUBMIT REQUEST TO LOWER FOOTINGS UP TO 48" IF THEDEPTH AND LOCATION OF PIPE OR CONDUIT DO NOT COMPLY WITH THIS DETAIL.DO NOT PROCEED WITHOUT SEOR APPROVAL.
FIN FLR
BOT OF FTGPER PLAN
NO PIPES OR CONDUIT MAYBE LOCATED BELOW THISLINE AT ANY FOOTING UNO
NO PIPES OR OTHER OBJECTSARE ALLOWED IN FTG UNLESSSPECIFICALLY SHOWN ONSTRUCTURAL PLANS
PIPE OR CONDUITPER PLANS, TYPICAL
STRUCTUREPER PLAN
212
1
9''.
NO EXCAVATION SHALL EXTENDBELOW THIS LINE WITHOUTAPPROVAL BY SOILS ENGINEER.
BACKFILL AND COMPACTPER SPECIFICATIONS ANDGEOTECHNICAL REPORT
BOTT OF FTG
21
1
2
9"
1'6''MIN
10'0''.
EXCAV
TRENCH
NOTE:THE CONTRACTOR SHALL BE RESPONSIBLE FORSHORING OR OTHERWISE MAINTAINING THE SIDES OF THEEXCAVATION FROM CAVE-INS UNTIL ALL BACKFILL ISCOMPLETED PER SPECIFICATIONS AND GEOTECHNICALREPORT.
CONSTRUCTION JOINT (CJ)
SMALL RADIUS TOOL@ EXPOSED JOINTS
SAWCUT (SC) WITHIN24 HOURS OF
CONCRETE POUR
UNDERLAYMENT PER PLANAND GEOTECHNICALREPORT,TYPICAL
1ST POUR 2ND POUR
SAWCUT CONTROL JOINTSAT 15' 0" OC MAX EA WAYPERPENDICULAR TOCONSTRUCTION JOINTS
STRUCTURAL SLAB ON GRADESHALL BE CONTINUOUSLYPOURED IN STRIPS NOT TOEXCEED 60 FEET x 120 FEET
NOTES:1. SEE ARCHITECTIRUAL PLANS FOR LOCATIONS OF VISUALLY EXPOSED CONTROL JOINTS.2. FOR POURING SEQUENCE OTHER THAN THAT SHOWN ON THESE PLANS, SUMIT SHOP
DRAWINGS TO SEOR FOR REVIEW 7DAYS PRIOR TO POUR.
CONSTRUCTIONJOINTS BETWEENPOUR STRIPS
SC OR CJ EACH WAY, TYPICAL
EDGE OF SLAB,WALL OR OPENING
TRANSVERSECONSTRUCTIONJOINT
CONSTRUCTION JOINT
SAWCUT CONTROL JOINT
SLAB PER PLAN
RE-ENTRANT CORNER
A
B
C
D
CJ
CJ
CJ
SC
SC
SC
SC
SC
SC CJ
3/4''DIA. X 24''PLAIN STELLROD @ 24''OC (WRAP ONEEND W/ BLDG PAPER).TYP @MID- DEPTH OF SLAB
1'0''.
WID
TH
PO
UR
ST
RIP
T/4
T
S S
NOTES:1. FOR FTG REINFORCING SEE PLANS AND DETAILS.2. VERTICAL WALL DOWELS SHALL EXTEND TO BOTTOM OF FOOTING.3. TRANSVERSE STEEL NOT SHOWN FOR CLARITY.4. TWO STEPS ARE SHOWN, DETAIL FOR SINGLE STEP OR ADDITIONALSTEPS IS SIMILAR.
LOCATION OFSTEP INDICATEDON PLAN:
REINFORCING TOMATCH LONGITUDINAL
TOP BAR WHEREOCCURS,TYP
90° BEND, TYPICAL
B.O.FOOTINGPER PLAN
"D"M
IN
1'-6"M
AX
"S"
"D"
UNO,TYPLAP SPLICE
MIN
"S"
MIN
2 "S"
"D"
LIGHTPOLE ANDANCHOR BOLTSPER LIGHTPOLEMANUFACTURER
(6) #5 VERT W/#3 TIES @ 6"OC
(3) TIES AT TOP 5"
3/4'' CHAMFER
2" MAX NON-SHRINK GROUT
2'0''DIA.CLR
3''MIN
3''C
LR
2' -
6"
5'6
''MIN
2' -
6"
LIG
HT
PO
LE
HE
IGH
T18'0
''MA
X
5"
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:3
8 P
M
S-9.02
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.02
TYP CONC PAD AND CURB 1
SCALE: 3/4" = 1'-0" S-9.02
3TYP ISOLATED EQ PAD
SCALE: 3/4" = 1'-0" S-9.02
4TYP PIPE AT PAD FOOTING
SCALE: 3/4" = 1'-0" S-9.02
5
TYP EXCAVATION PARALLELTO FOOTING
SCALE: 3/4" = 1'-0" S-9.02
TYP SLAB ON GRADE CONTROL JOIST 6
SCALE: 3/4" = 1'-0" S-9.02
7TYP STEPPED FOOTINGSCALE: 3/4" = 1'-0" S-9.02
8TYP LIGHTPOLE FOUNDATIN
NOTES:1. FOOTINGS POURED AGAINST EARTH ARE SUBJECT TO APPROVAL OF GEOTECHNICAL ENGINER.2. FOOTING WIDTHS SHALL NOT BE MORE THAN 4" WIDER THAN SHOWN ON PLAN.3. FORMWORK NOT PERMITTED BELOW GRADE UNLESS FULLY FORMED.4. FOUNDATION CONCRETE MAY BE PLACED DIRECTLY INTO NEAT EXCAVATIONS PROVIDED THE FOUNDATION TRENCH WALLS ARE STABLE AS DETERMINED BY THE GEOTECHNICAL ENGINEER. THE MINIMUM FORMWORK SHOWN ON THE DRAWINGS IS MANDATORY TO ENSURE CLEAN EXCAVATIONS IMMEDIATELY PRIOR TO AND DURING THE PLACING OF CONCRETE.5. CONT CLEAN-OUT STAKES NOT PERMITTED IN THE FTG AREA.6. AFTER CONCRETE HAS SET, REMOVE LAITANCE AND SCUM.
CUT BACK SPALL
NEAT CUT TRENCH
MINIMUM FORMWORK(UNLESS FULLY FORMED)
CONTINUOUSCLEAN-OUT
2X PLANKINGTYP
6"
MIN
3 1
/2"
MIN
CL CURB
CLEAN AND INTENTIONALLYROUGHEN TO A MINIMUMAMPLITUDE OF +/- 1/4"
2x12 TYP
CUT BACK SPALL
NEAT CUT TRENCH
ON DWG +2''MIN
FOOTING WIDTHSHOWN
ON DWG +2''MIN
FOOTING WIDTHSHOWN
NOTES:1. FOOTINGS POURED AGAINST EARTH ARE SUBJECT TO APPROVAL OF GEOTECHNICAL ENGINERR.2. FOOTING WIDTHS SHALL NOT BE MORE THAN 4" WIDER THAN SHOWN ON PLAN.3. FORMWORK NOT PERMITTED BELOW GRADE.4. FOUNDATION CONCRETE MAY BE PLACED DIRECTLY INTO NEAT EXCAVATIONS PROVIDED THE FOUNDATION TRENCH WALLS ARE STABLE AS DETERMINED BY THE GEOTECHNICAL ENGINEER. THE 2x12 SHOWN IS MANDATORY TO ENSURE CLEAN EXCAVATIONS IMMEDIATELY PRIOR TO AND DURING THE PLACING OF CONCRETE.5. STAKES NOT PERMITTED IN THE FOOTING AREA.
NOTES:1. CONTRACTOR SHALL COORDINATE ALL PIPELOCATIONS WITH BUILDING FOUNDATIONREQUIREMENTS.2. IF REQUIREMENTS AS SHOWN CANNOT BEMET, STEP FOOTING PER TYPICAL 'STEPPEDFOOTING' DETAIL.3. REFERENCE CBC SECTION 1805A.4.7
PIPE TRENCH SHALL BELOCATED SO THAT FTGWILL NOT BEUNDERMINED
NO PIPES TO BE PLACEDWITHIN THIS HEIGHT
INSIDE DIA. OF METAL SLEEVESHALL BE 2" MIN LARGERTHAN OUTSIDE DIA. OF PIPE
PIPE
PLACE CONC FILL AROUNDSLEEVES BEFORE POURINGFTG PADS. FILL SHALL BE SAMEWIDTH AS FTG AND FULL WIDTHOF THE PIPE TRENCH.
NO EXCAVATION ALLOWEDBELOW THIS LINE
TO BE POURED AGAINSTUNDISTURBED SOIL
POUR JOINT
POUR JOINT
BACKFILL PERSPECIFICATIONS
NO PIPE SHALL PASSTHROUGH THE FTG INTHIS REGION
FTG SHALL BE STEPPED SOTHAT THIS DIM DOES NOTEXCEED 3'-0" IN ANY CASE
SECTION
21
9"
A-A
2'0
''MA
X.
1'6''MIN
2'-6''MIN
TYP
1'6''MIN
2''M
INM
IN
4''.
1' -
4"
MIN
6''.
A-A
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:3
8 P
M
S-9.03
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.03
FOOTING POURED AGAINST EARTH 1
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.03
PIPE TRENCH FOOTING DETAIL 2
AREINFORCEMENT CENTERED IN CMU BLOCK
BREINFORCEMENT AT EDGE OF CMU BLOCK/MULTIPLE BARS
DSTRAIGHT DEVELOPMENT
CSTD HOOKS
EDGE BAR/MULT BARS
90° HOOK
180° "U" HOOK
POINT AT WHICH BARMAY BE CONSIDEREDFULLY DEVELOPED
SINGLE BARCTR'D
48DB
(IN)
BARSIZE
#3 5
STDHOOKLE (IN)
72DB
(IN)
POINT AT WHICH BARMAY BE CONSIDEREDFULLY DEVELOPED
VERT SECT HORIZ SECT
SINGLE LAYER OFBARS EACH DIRECTION
LAP SPLICE BARS ASSHOWN TO MAINTAIN
CONSTANT EDGEDIST., WIRE IN PLACE
SINGLE BAR PER CELLIN EACH DIRECTIONSHOWN, DO NOTCOUNT SPLICE ASMULT BARS
UNO ON PLANS, VERT BARSARE TO BE CTR'D, HORIZBARS TO BE TOWARDINTERIOR FACE
VERTICAL BAR ONOUTSIDE FACE, UNO
LAP SPLICE BARS ASSHOWN TO MAINTAIN
CONSTANT EDGEDISTANCE, WIRE IN PLACE
SPLICE AND DEVELOPMENTLENGTH PER "SINGLE BAR,CTR'D IN BLOCK" PERSCHEDULE, UNLESS MULTIPLEBARS OCCUR IN SAME CELLOR COURSE IN SAMEDIRECTION
SPLICE AND DEVELOPMENTLENGTH PER "EDGE BAR /MULT BARS" AS SHOWN INSCHEDULE
BOND UNIT SHOWN
VERT SECT HORIZ SECT
#4#5#6#7#8#9
78
10121315
18
243036424854
27
364554637281
18
364554637281
18
364554637281
LAP SPLICE & DEVELOPLENGTH LD (IN) UNO
ALL C
MU
UNO
EQ
UNO
EQ
2.5''CLR@BARS>#52''CLR@#5,#4,#3
PARALLEL BARS1''MIN CLR BTWN
BTWN BARS & CMU1/2''MIN CLR
L
DEVELOPMENT LENGTH
D
BD
E
B
LENGTH L
MIN HOOK EMBED
DD
B
NOTES:1. VALUES SHOWN ARE FOR GRADE 60 REINF DEVELOPED IN CMU.2. REFER TO TYPICAL REINFORCEMENT DETAILS FOR INFO NOT SHOWN, AND FOR DEVELOPMENT IN CONCRETE.3. LAP SPLICES OF REINFORCEMENT WITH WORKING STRESS LEVELS HIGHER THAN 80% FS SHALL BE 72D LONG, OTHERWIDE 48D SPLICES SHOWN ON THIS SCHEDULE AND THESE PLANS ARE BASED ON THIS RULE.
B B
#4 TO MATCH VERTBAR SPACING, TYPUNO ON PLANS
REINF MAT:SINGLE DOUBLE
STD 180° OR 90°HOOK INTO WALL,ALT DIR OF HOOK
(2) #5 UNOON PLANS
SEE "A" FORINFO NOT NOTED
REINF: MAX OPNG:(2) #5 5' 0"(2) #6 7' 0"(2) #7 10' 0"
#4 TO MATCH HORIZSPACING, TYP UNO
STD 180° OR 90°HOOK DOWN
SEE NOTE #8
REINF MAT:SINGLE
DOUBLE
FULL HOOPW/ 135° BEND
U-BEND, ALIGNW/ HORIZ
SEE "C" FOR INFO NOT NOTED
#3@8" OC, TYP UNO, CONT2'-0" ABV & BELOW OPNG
EXTEND LINTEL AND SILL BARS 48D MINIMUM PAST EDGE OF OPENING.NOTES:1.SEE PLANS FOR TYPICAL AND ADDITIONAL REINFORCEMENT.2.FOR OPENINGS 36" OR LARGER IN WIDTH USE FULL HEIGHT JAMB BARS. EXTEND TO TOP OF WALL AT UPPER/SINGLESTORY, 48D MIN PAST FLOOR AND INTO FOOTING.3.AT OPENINGS LESS THAN 36" IN WIDTH, EXTEND JAMB BARS 48D PAST EDGE OF OPENING.4.FOR MINOR OPENINGS THAT DO NOT INTERRUPT TYPICAL REINF, ARE NO LARGER THAN 24" SQ, AND ARE AT LEAST 24"FROM ADJACENT OPENINGS OR WALL EDGE, NO ADDITIONAL REINF IS REQ'D UNO ON PLANS.5.USE A TYPICAL LAP SPLICE UNO ON PLANS.6.WHERE FULL EXTENSION IS NOT POSSIBLE, EXTEND BARS AS FAR AS POSSIBLE AND USE A STD HOOK.7.EXTEND LINTEL AND SILL BARS 48D MINIMUM PAST EDGE OF OPENING.8.AT FULL HEIGHT JAMB BARS, THE WEB AND SHELL MAY BE REMOVED TO FACILITATE INSTALLATION. THE CONTRACTORSHALL ENSURE THAT GROUTING WILL NOT BE COMPROMISED IF THIS OPTION IS USED.
WALL ELEVATION
SEE NOTE #6
JAMB TYP, SEE "C"AND NOTE #2
LAP SPLICE,TYPICAL,SEE NOTE #5
LINTEL TYP,SEE "B"
MULTI-STORYCONDITION
STACKED OPENING
JAMB EXTENSION,TYP, SEE NOTE #2
SMALL OPENING,SEE NOTE #3
MINOR OPENING,SEE NOTE #4 FOOTING EMBED,
TYPICAL, SEENOTES #2
JAMB EXTENSION,TYP, SEE NOTE #2
TOP OF WALL,SEE "A"
SILL TYP,SEE "A"
PIER,SEE "D"
LINTEL & SILL,TYP, SEE NOTE #7
*MIN LINTEL DEPTH = 2' 8" UNO
(1) #5
(2) #5 UNOON PLANS
TOP OF WALL & SILLELEVATION SECTION
AJAMB PLAN SECTION
C
PIER PLAN SECTIOND
LINTEL ELEV SECTIONB
REINF MAT:SINGLE DOUBLE
(1) #5U-BEND REINF MAT:
SINGLE
DOUBLEU
NO
2'8
''MIN
TYP UNO2 1/2''CLR
SP
LIC
E
LA
P
LAP SPLICE
SP
LIC
E
LA
P
5T MAX
3T MIN
TT
CONTROL JOINT, LOCATIONPER PLANS AND NOTES
POTENTIALCRACK LOCATION
TERMINATE EVERY OTHERHORIZ BAR AT JOINT, EXCEPTFOR ROOF AND FLOOR CHORDBARS AND LINTEL BARS
PROVIDE #5 VERT (MIN)EACH SIDE OF JOINT OR(2) #6 @ 12" CMU
BACKER ROD
RAKED OR CONCAVE JOINT,FILL WITH SEALANT
STACKED BOND AT CELLADJACENT TO JOINT
OPEN-ENDEDBOND UNITSSHOWN FORCLARITY
EXPANSION JOINT, LOCATIONPER PLANS AND NOTES
USE CLOSED ENDEDBLOCKSAT JOINT
TERMINATE ALT HORIZBARS AT JOINT, NOEXCEPTIONS
PROVIDE #5 VERT (MIN)EACH SIDE OF JOINT OR(2) #6 @ 12" CMU
BACKER ROD
RAKED OR CONCAVEJOINT, FILL WITH SEALANT
STACKED BOND AT CELLADJACENT TO JOINT
OPEN-ENDED BONDUNITS SHOWN FORCLARITY
NO GROUT IN JOINT
NOTE:DO NOT SUBSTITUTE EXPANSION JOINTS FOR CONTROL JOINTS. EXPANSIONJOINTS PROVIDE COMPLETE STRUCTURAL DISCONTINUITY, USE ONLYWHERE SPECIFICALLY NOTED ON THE PLANS.
(2) #5 VERT, MIN
ONE LAYER OF REINFORCING
TWO LAYERS OF REINFORCING
#5 VERT,MIN
STD HOOK INNERBARS AT CORNER
NOTE:LAP SPLICES MAY BE USED ATBENT CORNER BARS UNO ONPLANS, TYPICAL
FACE SHELL MAY BEREMOVED W/ OPENEND UNITS FULLHEIGHT AT WALLINTERSECTIONS,TYPICAL
FACE SHELL MAY BEREMOVED W/ OPENEND UNITS FULLHEIGHT AT WALLINTERSECTIONS,TYPICAL
BOND UNITS SHOWNFOR CLARITY
B
B
(2) #5 VERT, MIN
LAP SPLICE
48D
LAP SPLICE
48DB
LAP SPLICE
48D TYP
LAP SPLICE
48DB
....
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
As indicated
9/2
8/2
015 1
0:5
8:3
9 P
M
S-9.04
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.04
TYP CMU REINF DETAILS & DEVLOPMENT LENGTHS 1
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.04
TYP MIN REINF FOR MASONRY OPENINGS 2
SCALE: 3/4" = 1'-0" S-9.04
3
TYP CMU WALL CONTROLJOINT
SCALE: 3/4" = 1'-0" S-9.04
4
TYP CMU WALL EXPANSIONJOINT
SCALE: 3/4" = 1'-0" S-9.04
5CONC MASONRY WALL INTERSECTION
BOLT DIAMETER + 2" MINOPENING IN CMU FACE
GROUTED CMU WALLPER PLANS
BOLT EXTENSION AS REQ'DTO FULLY ENGAGE NUT &WASHERS, TYPICAL
HEX HEADED A307 BOLT(UNO) GROUTED IN PLACEIN FACE OF WALL
EMBEDMENT SHALL BE THESMALLER OF 10XDIAM OR(WIDTH - 1.5")
10XDIAM EMBEDMENT UNO
HEX HEADED A307 BOLT(UNO) GROUTED INPLACE IN TOP OF WALL
NOTE:UNLESS DETAILED ON THESE PLANS, DONOT PLACE BOLTS IN FACE OF WALL < 12DIAM FROM OPENINGS OR EDGES WITHOUTAPPROVAL FROM SEOR
EQ EQ
.
CLR1.5''MIN
.
. .
MINIMUM EMBEDMENT TABLE
DIAMETER OF BOLTS IN INCHES 1/2 5/8 3/4 7/8 1 1 1/8
EMBEDMENT IN INCHES 4 5 6 7 8 9
BOLT
GROUT1''C
LR
NOTE:1. BOLTS CAST-IN MASONRY SHALL BE GROUTED IN PLACE WITH 1" OFGROUT BETWEEN BOLT AND MASONRY.2. BOLTS SHALL BE A307 HEADED MACHINE BOLTS OR A36 ROD W/TACKWELDED HEX NUT.3. CONTRACTOR SHALL ONLY USE "DRILL-IN" BOLTS IN PLACE OF CAST-INBOLTS SHOWN ON STRUCTURAL DRAWINGS WHEN TYPE AND EMBEDMENTDEPTH ARE APPROVED BY THE STRUCTURAL ENGINEER, AND THECONTRACTOR WILL PAY FOR ANY REQUIRED TESTING OF "DRILL-IN" BOLTS.
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
0 P
M
S-9.05
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.05
1
TYP HEADED BOLTGROUNTED IN CMU WALL
SCALE: 3/4" = 1'-0" S-9.05
2BOLTS IN CONC MASONRY
A AT BOUNDARIES PARALLEL TO DECK
CLOSURE PLSEE NOTE
B AT BOUNDARIES PERPENDICULAR TO DECK
B3
B1 B2 B3
SIDE LAPPER
3
-
SECTION
CL SPLICE
D1LAP SPLICE D2BUTT SPLICE
CL SPLICE
D3CONT. DECK
DAT INTERIOR BEAMS PERPENDICULAR TO DECK
CAT INTERIOR BEAMS PARALLEL OR SKEWED TO DECK
PERPENDICULAR TO DECK
EAT INTERIOR STRUT
PARALLEL OR SKEWED TO DECK
FAT INTERIOR BOXED BEAM
NOTE:DO NOT SPLICE DECK AT STRUT MEMBER
PERPENDICULAR TO DECK PARALLEL OR SKEWED TO DECK
NOTE:DO NOT SPLICE DECK AT BOXED BEAM MEMBER
* NOTE: ALL WELDS CAN BE SUBSTITUTED BY #12 SELF DRILLING TEK SCREWS
NOTES:1.SEE METAL DECK NOTES ON SHEET S-1.022.ALL DECK SHALL HAVE 2 1/2" MIN BEARING ON END SUPPORT, 1 1/2" MINBEARING ON SIDE SUPPORT TYP., U.N.O.3.TSW REFERS TO TOP SEAM WELD. SEE DETAIL 3/-.4.VSC REFERS TO VERCO SIDELAP CONNECTION.5.SEE DETAIL 4/- FOR WELDING PATTERN.6.ALL STEEL DECK SHALL BE GALVANIZED, U.N.O.7.NO LOADS OF ANY KIND SHALL BE HUNG FROM ROOF DECK UNLESSSPECIFICALLY DETAIL ON STRUCTURAL DRAWINGS.8.ALL PUDDLE WELDS SHALL HAVE AN EFFECTIVE FUSION AREA AT LEASTEQUIVALENT TO 3/8" X 1" LONG OR 3/4" IN DIAMETER. PUDDLE WELDMAY BE OMITTED WHERE LOCATION COINCIDES WITH SHEAR STUDSWELDED THROUGH METAL DECK.9.SEE DETAIL 2/S-9.07 WHERE THE SLOPE OF THE METAL DECK REQUIRESBENT PLATE
SYMBOLMETAL DECKDESIGNATION
GAGECONC.FILL &REINF.
METAL DECK ATTACHMENT TOSUPPORT DECK TO
DECK SIDELAP
ATTACHMENT
SHEARTRANZ
II
DECK PROPERTY
AT BOUNDARY DECKPERPENDICULAR TO
SUPPORT
AT BOUNDARYDECK
PARALLELTO SUPPORT
I (IN4) +S(IN3) -S(IN3)
D1VERCO
B-FORMLOCK20
3 1/2"LTWTCONC.
7 PUDDLEWELDS
PER PANEL
PUDDLEWELDS @ 12"
O/CTSW @ 6" O/C NO 0.219 0.230 0.237
BOUNDARYWELD PERSCHEDULE
BOUNDARYWELD PERSCHEDULE
BRG1 1/2''MIN
BOUNDARYWELD PERSCHEDULE
BOUNDARYWELD PERSCHEDULEBRG
1 1/2''MIN
1/8 2-6
AT DECKSPLICEWHEREOCCURS*
BRG1 1/2''MIN
BRG1 1/2''MIN
1/8 2-6@12''O/C*
@12''O/C*
TYP2''MIN
@12''O/C*
@12''O/C*
2 1/2'' BRG
"D"
1/8 1-12
PERSCHED
NOTE:CLOSURE PL. THKAROUND INT OPENINGSU.N.O- 16GA FOR "D" = 3" MAX- 16GA FOR "D" = 3" MAX- 10GA FOR "D" = 8" MAX
PERSCHED
B3
D2 VERCOB-FORMLOCK
204 3/4"LTWTCONC.
7 PUDDLEWELDS
PER PANEL
PUDDLEWELDS @ 12"
O/CTSW @ 6" O/C NO 0.219 0.230 0.237
3/16" DIA BUTTONPROTRUDES NOTICEABLYINTERLOCKING UNITS @12''O.C.
WELD CLINCH FIRST TO GETCONTACT OF LIPS - 1 1/2''LONG WELD MUST ENGAGETOP OF INNER LEG PERSCHEDULE
CLINCH FIRST TO GET CONTACTOF LIPS - 1 1/2'' LONG WELDMUST ENGAGE TOP OF INNERLEG AND HAVE FUSION TOP ANDBOTTOM
EFFECTIVE MINIMUM 1/2'' DIAOR 3/8''x1'' LONG (NO WELDWASHERUSED)
A ROOF DECK PUDDLE WELD B DECK PLUG WELD
THROUGH 3/8'' DIA HOLEIN 14 GA WELD WASHER
C BUTTON PUNCH D TOP SEAM E SIDE SEAM WELD
WELDS TO SUPPORT
SIDE LAP FASTENING
4 - WELD PATTERN
7 - WELD PATTERN
4 - SCREW PATTERN (#12 SCREWS)
7- SCREW PATTERN (#12 SCREWS)
IF OPENINGS ARE CLOSER OR LARGERTHAN SHOWN, REINFORCE DECK PERTYP OPENINGS IN METAL DECK DETAIL
DE
CK
WE
BS
DO
NO
T C
UT
THRU TOP FLUTE4''DIA MAX
THRU BOTTOM FLUTE2''DIA MAX
BUT NOT LESS THAN 12'' EA WAY6 DIA OF LARGER OPENING
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
1 P
M
S-9.06
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.06
TYP METAL DECK DETAILS AND SCHEDULE 1
SCALE: 3/4" = 1'-0" S-9.06
3TYP METAL DECK WELDING
SCALE: 3/4" = 1'-0" S-9.06
4TYP METAL DECK WELDING/SCREW PATTERNS
SCALE: 3/4" = 1'-0" S-9.06
5PIPE PENETRATIONS AT DECK WITHOUT FILL
CONSTRUCTION JOINT CLEAN ANDINTENTIONALLY ROUGHEN SURFACETO A MIN AMPLITUDE OF PLUS ORMINUS 1/4"
KEYS 12" LONG X DEPTHOF CONC OVER DECK AT 48"
NOTE:SLAB REINF CONT THRU JOINT.
REINF NOT SHOWNFOR CLARITY
CONC FILLPER PLAN
REINF PER PLAN
PLAN
A-A
SECTION A-A
1"
PE
R P
LA
N
SLA
B T
HIC
KN
ES
S
OMIT THESE BARS ALONGSIDES OF OPENING'SSMALLER THAN 12"
NOTES:1.PROVIDE (2) #4X5' 0" AT ALL RE-ENTRANT CORNERS AND AT ALL OPENINGS GREATERTHAN 6' 0" SUCH AS ELEVATOR, STAIR OPENINGS AND AIR SHAFTS.2.ALL OPENINGS LARGER THAN 2' 0" SQ REQUIRE PERIMETER SUPPORT AND ARE TO BEAPPROVED BY STRUCTURAL ENGINEER.
SEE NOTE 1
#4 TYP
PLAN
1 1
/2''T
YP
2'6''MIN
2'6''MIN
2'6''MIN
1 1/
2''TYP
3/16 RIDGE PL
RIDGE OR HIPBM SEE PLAN
ROOF BMSEE PLAN
AT RIDGE
AT SLOPED PLATE AT EAVE
T.O.S.
3/16 BENT PLCONT
ROOF BM
3/16 BENT PLCONT TYP.
T.O.S.
3/16 BENT PLCONT
T.O.S.2 11/16"
MIN
3/161 1/2-12
TYP
TYP5/16''.
3/161 1/2-12
5/1
6''.
3/161 1/2-12
5/16''.
3/161 1/2-12
3/161 1/2-12
1/4
''.
3/161 1/2-12
MIN2 11/16''.
NOTE:X=8" MAX, WHERE X>8, SEE 12/-
ELEVATOR SILL ANDCONNECTION BYGENERALCONTRACTOR
CONCRETE FILL OVERMETAL DECK SEE PLAN
CL BEAM
1/2" BENT PLATE (OR1/2" ANGLE) W/ 3/4"DIAx 5" NELSON STUDANCHORS @ 12" OC
FOR DECKORIENTATIONSEE PLAN
STEEL BEAMSEE PLAN
3/4
'' C
LR
3/16 4-12
4''MIN 4''MIN
'X'
4''.
WELDED STUDWHERE OCCURS
DECK PARALLEL
DECK PERPENDICULAR
CONC FILLFLOOR DECK
ADDL (2) #4 CONT
L4X3X1/4" (LLV) @ 11'-0"OCMAX ALIGN W/ "OPP BEAM"AND LOCATE AT EDGE FORMSPLICE AND TERMINATION
1/2"DIA NELSONDEFORMED BAR ANCHOR@ 16" OC LAP W/ REINF
1/2"DIA NELSONDEFORMED BARANCHOR @ 16"OCLAP W/ REINF
L4X3X1/4" (LLV) @ 11'-0"OCMAX ALIGN W/ "OPP BM" &LOCATE AT EDGE FORMSPLICE AND TERMINATION
2" MIN BEARINGAT DECK
CONC FILLFLOOR DECK
10GA EDGE FORM
(3) #4 CONT
EOD
2" MIN BEARINGAT DECK
CLOSURE PL
CONC FILLFLOOR DECK
"OPP BEAM"
1/4" CONT BENT PL
REINFPER PLAN
REINFPER PLAN
2" MIN BEARINGAT DECK
CLOSURE PL
CONC FILL FLOOR DECKDIRECTION PER PLAN
REINFPER PLAN
CURTAIN WALLPER ARCH
1/4" CONTBENT PL
(1) #4 CONT
CLOSURE PL
CONC FILL FLOOR DECK
REINF PER PLAN
10GA EDGE FORM
(1) #4 CONT
EOD
REINF PER PLAN
#4 @ 16"OC180° HOOK
36"
CONC FILL FLOOR DECK
2" MIN BEARINGAT DECK
STEEL BM
REINFPER PLAN
EXTERIOR WALLPER ARCH
10GA EDGEFORM
EOD
10GA EDGE FORM
(1) #4 CONT
EOD
STEEL BM
#4 @ 16"OC180° HOOK
42"
"OPP BEAM"
STEEL BM
#4 @ 16"OC180° HOOK
36"
#4 @ 16"OC180° HOOK
42"
STEEL BM
1 5
/16"
CLR
1/8 3-12
1 5
/16''C
LR
4''MIN
BEARING2 11/16''MIN
1''0''MAXEOD PER PLAN
OR AISCMIN
. 1''
BEARING2 11/16''MIN
>12'',1'6''MAX
EOD PER PLAN 2'0''MIN
1 5
/16''C
LR
3/16 3-12
OR AISCMIN
1'' .
BEARING2 11/16''MIN
1/8 3-12
>1',1'6''MAXEOD PER PLAN
1 5
/16''C
LR
3/16 3-123''MIN
BEARING2 11/16''MIN
1'0''MAX
EOD PER PLAN 2'0''MIN
1/8 3-123''MIN
BEARING2 11/16''MIN
1'0''MAX
EOD PER PLAN
1 5
/16''C
LR
>12'',1'6''MAX
EOD PER PLAN
1 5
/16''C
LR
WELDED STUDWHERE OCCURS
WELDED STUDWHERE OCCURS
WELDED STUDWHERE OCCURS
WELDED STUDWHERE OCCURS
WELDED STUDWHERE OCCURS
WELDED STUDWHERE OCCURS
#4 EA SIDE OF PAD, EXTEND24" EA SIDE PAST OF CURB
#4 EA CORNER @18"OC MAX EA WAY
1'0''TYP
PLA
N
SE
E
AR
CH
SE
E
CLR2 11/16''CLR
2 1
1/1
6''C
LR
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
1 P
M
S-9.07
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.07
4TYP CONST JOINT AT DECK WITH CONC FILL
SCALE: 3/4" = 1'-0" S-9.07
5TYP SLAB ON METAL DECK OPENING
SCALE: 3/4" = 1'-0" S-9.07
2TYP SLOPED DECK TO BEAM DETAILSCALE: 3/4" = 1'-0" S-9.07
3EDGE CLOSURE AT ELEV SOLL SUPPORT
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.07
EDGE OF CONC FILL DECK (EOD) AT FLOOR/ROOF 1
SCALE: 3/4" = 1'-0" S-9.07
6EQUPMENT PAD
WELDED STUDSWHERE OCCURS
NOTE:AT LOCATIONS WHERE CLEARANCE 'X' TO STUD IS LESS THAN 1 1/2", PROVIDECLOSURE BELOW HIGH FLUTES ONLY AND PLACE STUDS ADJACENT TO LOWFLUTES.
BM PER PLAN
18 GA CLOSURE PLSEE NOTE
METALDECKSEE PLAN
GIRDERFILLERAS REQD
CL BM
GRID
#4 x 5'-0" @ 18"OC
HOOK ENDS OFADD'L BOT BARSWHERE OCCURS
SLAB REINFSEE PLAN
SE
E P
LA
N
'X' 2''MIN
2''MIN 2 11/16''MIN
3/4DIA 6
NOTES:1. SEE MECH DWGS FOR ADDITIONAL INFORMATION.2. SEE PLAN FOR MECH EQUIPMENT LOCATIONS.
SEE MECH DWGSFOR ATTACHMENT
BEAM/GIRDERPER PLAN
MECH. UNIT CURBPER MECH DWGS
BEAM PER PLAN,WHERE BEAM /SIZENOT SHOWN PROVIDEW12X22 TYP
A/C UNIT/MECH'L EQUIPMENT(MAX OPERATINGWEIGHT 2000 LBS)
3/8" BENT PLPER 4F/-.(TYP.)
CURB TO BENT PL.ATTACHMENT PER 1/M-502
INSULATION PER ARCHT'L
BEAM PER PLANWHERE OCCURS FRAMING BEYOND
MTL DECKPER PLAN
3/16
3/16PL TOBM TYP
SEE MECH DWGSFOR ATTACHMENT
MECH. UNIT CURBPER MECH DWGS
3/8" BENT PLPER 4F/-.(TYP.)
BEAM PER PLAN,WHERE BEAM /SIZENOT SHOWN PROVIDEW12X22 TYP
FRAMING BEYOND
INSULATIONPER ARCHT'L
MTL DECKPER PLAN
BEAM/GIRDERPER PLAN
CURB TO BENT PL.ATTACHMENT PER 1/M-502
LEVEL FOR MECH.CURB ATTACHMENT
NOTES:1. SEE MECH DWGS FOR ADDITIONAL INFORMATION.2. SEE PLAN FOR MECH EQUIPMENT LOCATIONS.
A/C UNIT/MECH'L EQUIPMENT(MAX OPERATINGWEIGHT 2000 LBS)
3/16
3/16BENT PLTO BM
TYP
A
B
1/2" MAX
C
D
E F
D
E
C
OPENING GREATER THAN 18" TO 60"
METALDECK TYP
WF BEAMPER PLANTYP
NOTES:1. FRAMING AROUND DECK OPENINGS TO BE FURNISHEDAND INSTALLED BY STRUCTURAL STEEL CONTRACTOR.2. PROVIDE CONT BENT PLATE ALL AROUND OPENINGSAT ROOF EXHAUST FAN, DUCT & PIPE PENETRATIONS,GRAVITY RELIEF VENT, & WHERE SHOWN ON MEP DRAWINGS.
3/4" DIA PUDDLEWELD EA FLUTE
L3x3x1/4 ALLAROUNDOPENING TYP.ANGLE IS NOTREQ'D FOROPENING WHEREONLY ONE VERTLEG OF DECK ISCUT
OPENING UP TO 18"
METAL DECKTYP
3/8" BENT PLx3 1/2" LONG
C6x8.2U.N.O
WF BEAM
TYP CHANNEL/WF BM CONN
7"
4"
C6x8.2U.N.O
C6x8.2U.N.O.
TYP CHANNEL / CHANNEL CONNECTION
3/8" STEEL PLATEW-2 7/8" DIA BOLTS
CL
TYP ANGLE / ANGLE CONN
L3x3x1/4 U.N.O.
TYP BENT PL / ANGLECONN AT ROOF
3/8" BENT PLALL AROUNDSEE NOTE #2
3/8" STIFF PL@3'-0" O.C.(6" END DIST)
L3x3x1/4 ORC6x8.2 U.N.O.
INSULATION
C6x8.2
1'6
''MA
X
TYP
2'0''MIN 1'6''MAX
1/4
3/16
3/16
3/16
AT STIFF3-SIDE
3/16 3-12
1/2''MAX
2xBOLT DIA3''.
.
TY
P
2xB
OLT
DIA
1/4
NOTES:1. SEE MECHANICAL DOCUMENTS FOR BALANCE OF INFORMATION.2. SEE DETAIL 2/- FOR STEEL ANGLE SIZE AND CONNECTION.
SEE "4/-" FORCLOSURE PLATE
EXHAUST FAN OR HOODSEE MECH DWGS
PRE-FAB CURB PERMANUFACTURER
FILLER AND NAILERPER MFR
INSULATION
SEE DETAIL 2/-
OPENING
3/16 4
PRE-FABCURB TO
PL EASIDE
2 1
/2''M
IN
INSULATION
2-#8X1/2''SELF-TAPPINGSCREW
STEEL STRAP 3"WIDE X 4" LONG X12GA(MIN), BENDTO ALIGN W/ WIRE
BRACING WIRE
STEEL DECKPER PLAN
HANGER WIRE-TIE TO#3 REBAR W/ 3 WRAPSAROUND REBAR ANDONE WRAP AROUND WIRE
#3 X 12"REBAR
STRUCTURALSTEEL MEMBER
CEILING CLIP W/SHOT-IN ANCHOR
STEEL STRAP
@ STEEL BEAMS
@ STEEL ROOF DECK
INSULATIONSTEEL DECKPER PLAN
INSULATION ORCONC. PER PLAN
STEEL DECKPER PLAN
METAL DECKHANGER FORROD HANGER
STEEL BEAMCLAMPFOR RODHANGER
ROD HANGER
ROD HANGER
STRUCTURALSTEEL MEMBER
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
2 P
M
S-9.08
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.08
1METAL DECK TRANSITION
SCALE: 3/4" = 1'-0" S-9.08
2TYP MECH EQUIP PAD TO METAL DECK
SCALE: 3/4" = 1'-0" S-9.08
3
TYP MECH EQUIP PAD TO METAL DECK @SLOPE
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.08
TYP FRAMING AT OPENINGS IN STEEL DECK 4
SCALE: 3/4" = 1'-0" S-9.08
5
TYP EXHAUST FAN& INTAKEHOOD ANCHORAGE
SCALE: 3/4" = 1'-0" S-9.08
6
TYP WIRE CONNECTION TOSTEEL FRAMING
SCALE: 3/4" = 1'-0" S-9.08
7
TYP ROD HANGER CONN TOSTEEL FRAMING
MTL. ROOF PANEL
CONT. TRACK TOMATCH STUD SIZEAND GAGE
WALL PERPENDICULAR TO PURLIN
WALL/BRACE PARALLEL TO PURLIN WALL/BRACE PARALLEL TO BEAM
(2) #10 SCREWS @EA PURLIN
METAL BUILDINGPURLIN
STUDS PERSCHEDULE
L3x3x16 GA CONT.ANGLE EA SIDE
MTL. ROOF PANEL
CONT. TRACK TOMATCH STUD SIZEAND GAGE
METALBUILDINGPURLIN
STUDS PERSCHEDULE
4"x16 GA STUD @32" OC,BEND WEB BACK 2" &ATTACH TO PURLIN W/(2) #10 SCREWS EA END
MTL BUILDINGBEAM
STUDS PERSCHEDULE
0.157" DIA SHOTPIN @ 16" OCSTAGGERED
(2) #10 SCREWEA STUD
CONT "SLIP-TRACK" TOMATCHSTUD SIZE& GAGE
MTL. ROOF PANEL
METAL BUILDINGPURLIN
STUDS PERSCHEDULE
BRACE PERPENDICULAR TO PURLIN
(3) #10 SMS
-
TYP.
--
-
-
--
-
-
-
-
-
-
-
-
BOTTOM OFSUPPORT
DBL. STUDS (MIN.) @JAMBS OF ALLOPENINGS TYP. U.N.O.PROVIDE 4 STUDS @JAMBS OF ADJACENTOPENINGS
WALL STUDBRACING WHEREREQUIRED SEE
BOTTOM TRACKSPLICE PER(WHERE REQ'D)
T/ CONC. LAB ORCONC. CURBWHERE OCCURS
SILL WHEREOCCURS
PROVIDE 1-BAY OF BLKG. EA.SIDE OF OPENINGS TOP,BOTTOM AND MID-HEIGHT SEE
DUCT OPENINGWHERE OCCURS
METAL STUDS PERSCHEDULE, TYP.
CABINETS OREQUIPMENT
LINE OF CONT. BLOCKING@ MID HEIGHT OF WALL
BACKING FOR CABINETSOR EQUIPMENTANCHORAGE, TYP. SEE
1. SEE WALL TYPES ON SHEET A-2.1 - A-2.2 AND SHEET A-8.0 FOR SIZE AND GAGE OF STUDS.
2.
NOTES:
TOP TRACKSPLICE PER(WHERE REQ'D)
ALL LOW VELOCITY SHOT PINS ARE HILTI X-U SHOT PINS (0.157" SHANK DIAMETER)UNLESS NOTED OTHERWISE. INSTALL PER THE REQUIREMENTS OF ICC-ES REPORT #2269.
203
8
15
8
15
11
19
12
11
7
16
7
TYP.
3. BRIDGING SHALL BE INSTALLED ON WALL FACES WITHOUT SHEATHING AND WHERESHEATHING DOES NOT CONTINUE TO THE TOP OF WALL.
4
-18
8
4'0''MAX 14'0''MAX 4'0''MAX
SPACING PER SCHEDULE
6"x16 GA. CONT.NOTCHED STUD.ANCHOR BACKINGTO 3 STUDS MIN.
(3) #10 S.M.S. TYP.
NOTE:
USE #10 S.M.S. WHEN ATTACHINGITEMS TO BACKING, U.N.O.
-
20 GA.x11/2" CONT.STRAP W/ (1) #10S.M.S. SCREW TOEA. STUD
CL. OF BRACING
STUD BLOCKING @ EA.END OF WALL & @8'-0" O.C. MAX. SEEDET.
METAL STUD
SPLICE WHERE REQ. @CL. OF BLOCKING
(8) #10 S.M.S. TO BLKG.
19
PIECE OF TRACK ORSTUD TO MATCH WALLSTUD GAGE. CUT WEB@ FLANGES & BENDWEB UP
METAL STUD
(2) #10S.M.S.
METAL STUDS
PIECE OF TRACK ORSTUD SAME GAUGE ASSTUDS
ALT. WELDED CONNECTION
SCREWED CONNECTION
1/8 1
TYP.EA.END
CUT WEB @ FLANGES& BEND WEB DOWN
12 GA.x3" STRAP @3'-0"O.C. EA. SIDEW/ #10 SMS TOEA. STUD
(1) #10 SMS EA. SIDE
(2) #10 SMS
JAMB STUDS
16 GA. CONT. TRACK
AT BOTTOM TRACK
AT TOP TRACK
(3) #10 SCREWSAT EA. SIDE
TYP. TRACKANCHORAGE
(3) #10 SCREWSAT EA. SIDE
24" LONG STUDSECTION TOMATCH TRACKGAGE
(2) STUDS BACKTO BACK AT SPLICE
3''MAX 3''MAX
1' - 0" 1' - 0" -
-
T/CONC. SLABOR CURB
CONT. TRACK TOMATCH STUDGAGE
BOTTOM TRACKANCHORAGE, SEEDET.
STUD BRACINGPER, TYP.
OMIT STRAP BRACINGON ANY PORTION OFWALL COVERED BYGYP. BOARD. REFERTO ARCH FORLOCATIONS
4
TOP OF SUPPORT
16
CONT. BLOCKING ATGYP. BOARD EDGE TOMATCH STUD GAGE.
(3) #10 SMS
-18
BRACING PERSCHEDULE
1
1±
BRACING SCHEDULE
WALL TYPE BRACE BRACE HT. (AFF) MAX BRACE LENGTH
R1 6" x 18 GA @ 16" O.C. 30'-0" 12'-0"
1A, 1B 27'-0" 15'-0"6" x 18 GA @ 16" O.C.
4'0
''MA
X
TY
P
4'0
''MA
X
(2) #10 S.M.S. @12" O.C., TYP.
600S162-54
MTL. STUDSPER WALL TYPESHEET A-8.0
CONT. TRACK TOMATCH STUD GAGEW/(2) #10 S.M.S. EA.STUD
T/CONC. SLABOR CURB
CONT. TRACK TOMATCH STUDGAGE W/ (2) #10S.M.S. EA. STUD
0.157"Øx11/4" EMBED.HILTI X-U SHOT PIN @16"O.C. MAX., U.N.O.
-
ADDITIONAL STUD @OPENINGS GREATERTHAN 4'-0"
DOUBLE STUDS
FOR FASTENINGSTUDS, SEE DET.
15
12 GA.x3" STRAP @ 3'-0"O.C. EA. SIDE W/ #10SMS TO EA. STUD
(3) #10 SMS EA. END
JAMB STUDS
BOXED STUDHEADER
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
As indicated
9/2
8/2
015 1
0:5
8:4
3 P
M
S-9.09
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 1/4" = 1'-0" S-9.09
TOP OF WALL/BRACE DETAILS 18
SCALE: N.T.S. S-9.09
METAL STUD WALL ELEVATION - TYPICAL 2
SCALE: 3/4" = 1'-0" S-9.09
20
TYP. BACKING AT METALSTUDS
SCALE: 3/4" = 1'-0" S-9.09
16TYP. METAL STUD BRACING
SCALE: 3/4" = 1'-0" S-9.09
19TYP. METAL STUD BLOCKINGSCALE: 1" = 1'-0" S-9.09
15
TYP. TRACK TO JAMBCONNECTION
SCALE: 1" = 1'-0" S-9.09
7TYP. TRACK SPLICE DETAILSCALE: 1" = 1'-0" S-9.09
3TYP. WALL SECTION
SCALE: 1" = 1'-0" S-9.09
12
TYP. BOXED HEADERSECTION
SCALE: 1" = 1'-0" S-9.09
4
TYP. STUD TO TRACKCONNECTION
SCALE: 1" = 1'-0" S-9.09
8TYP. JAMB STUDS
SCALE: 1" = 1'-0" S-9.09
11
TYP. BOXED HEADER TOJAMB
TOP TRACK STUDS
1 1/2"x18GA STRAP TYP.
CONT. BENT PL
NOTE:1 1/2"x18GA STRAP IS NOT REQUIRED WHEN "H" ISLESS THAN 3'-0".
DIAG STRAP
#10 SMS EA STUD
STUD FLANGE
DIAG STRAP
TRACK
#10 SMS
WALL ELEVATION
B C
BTYP
C TOP & BOT. TYP.
A
"H"
3@#10 SMS
STUD
CEILING JOIST
BRACING PER4
-
SUSPENDED METALSTUD PER
X
-
16GA BENT PL CONTWITH #10 SMS EALEG EA STUD/JOIST
IN-PLANE BRACINGPER 1
-
. 2''2''
.
3@#10 SMS
METAL STUDWALL ASOCCURS
SUSPENDED STUD& BRACE PER 4
-
CANT JOISTAS OCCURS
JOIST PER7
-
2
-
BRACE NOTREQ'DIF L2<4'-0"
2
-
TYP.
4"x16GA TRACKW/ #10 SMS TOEA. STUD
7
-
7
-
4"x16GA TRACKW/ #10 SMSTO EA. STUD
2'6''MAX
PER SCHED
L1
PER SCHED
L2
CL
IN-PLANEBRACINGPER
1
-
1
1
SUSPENDSTUDS PER
4"x16GA STUD(400S162 -43)@4'-0"O.C. W/ 3-#10 SMS EAEND(NOT REQ'D IF CLG/SOFFIT OCCURS & "L" < 4'0")
MTL STUDWALL ASOCCURS
CLG/SOFFIT FRAMINGAS OCCURS, SEE 2
-
4"x16GASTUDS@16"O.C.
6
-
"L"
7'0
''MA
X
.
#10 SMS @ 8" OCAT EA FLUTE
#10 SMS ATEA STUD.TYP
SUSPENDEDSTUD
WALL PERPENDICULAR TO DECK FLUTES
WALL PARALLEL TO DECK FLUTES
STEEL DECK
CONT 16 GA PLOVER 3 FLUTES
SUSPENDEDSTUD
#10 SMS ATEA STUD.TYP
NOTE:1. FOR METAL DECK W / CONCRETE , REPLACE #10 SMS TO HILTC X-CW / 1" MIN. EMBED POWER DRIVEN FASTENER
STEEL DECK
A
B
(1/16)1 1/2-16
TYP ATBOTHSIDES
OFTRACK
(1/16)1 1/2-16
TYP ATBOTHSIDES
OFTRACK
1
PL 1'-6"x3/16"(MAY BEOMITTED WHERE ANGLEALIGNS W/ LOW FLUTE)
600L150-68x1'-6"
3 - #10 SMS
DIAGONAL BRACE
PARALLEL TO DECK FLUTES
SECTION"1"
STEEL DECK
600L150-68
3-#10 SMS
DIAGONAL BRACE
2 #10 SMSEA FLUTE
PERPENDICULAR TO DECK FLUTES
NOTE:1. FOR METAL DECK W / CONCRETE , REPLACE #10 SMS TO HILTCX-C W / 1" MIN. EMBED POWER DRIVEN FASTENER
STEEL DECK 4 #10 SMS
B
A
INTERIOR METAL CEILING JOIST SCHEDULE
NOMINALSIZE
SSMA PRODUCTIDENTIFICATION
Ixx(IN )4
Sxx(IN )3 SPACING
(IN)MAXIMUM
SPAN
3 5/8"x20GA
4"x18GA
6"x18GA
8"x18GA
362S162-33
362S162-43
400S162-43
600S162-43
800S162-43
0.551
0.710
0.892
2.316
4.633
0.304
0.392
0.446
0.772
1.158
16
16
16
16
16
8'-6"
10'-0"
10'-4"
12'-0"
14'-0"
NOTES:1. JOIST AND TRACK DESIGNATIONS ARE BASED ON STEEL STUD MANUFACTURER'S ASSOCIATION(ICC ER-3064P).2. DESIGN LOADS: DEAD LOAD = 6 PSF , LIVE LOAD = 10 PSF
3. SEE TYP. CEILING JOIST FRAMING DETAIL
4. PROVIDE IN-PLANE AND OUT-OF-PLANE BRACING PER
3
-
1
-
STUD
BLKG.SIMPSON L30 @ 3 5/8'' OR 4''JOIST(2-#10SMS PER LEG)L50 @ 6" JOIST,(3-#10SMS PER LEG)L70 @ 8" JOIST,(4-#10SMS PER LEG
TRACKJOIST
JOIST AT WALL W/ #10SMS EA STUD(TRACKTO STUD)
JOIST INTO WALL
STUD
BLKG.
JOIST PARALLEL TO WALL
JOIST
BLKG.@24"
JOIST ATWALL W/ #10SMS EA STUD.
A B
1/16
TRACK TOSTUD
3 5/8"x18GA
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
4 P
M
S-9.10
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.10
1IN-PLANE BRACING
SCALE: 3/4" = 1'-0" S-9.10
2SOFFIT CONNECTIONS
SCALE: 3/4" = 1'-0" S-9.10
3INTERIOR CELING FRAMING
SCALE: 3/4" = 1'-0" S-9.10
4STUD BRACING
SCALE: 3/4" = 1'-0" S-9.10
5DETAIL_1
SCALE: 3/4" = 1'-0" S-9.10
6DETAIL_2
SCALE: 3/4" = 1'-0" S-9.10
7
METAL CEILING JOISTSCHEDULE
METAL STUD
SLIDE CLIP
STEEL WASHERS
(2)#10 SDSTS EASLIDE CLIP TOMETAL STUD
SLOT
"Z" PURLIN
"T" TRACK
SECTION PROPERTIES
NOTES:
1. ALL STEEL 54 MILS AND THICKER (16 GA AND THICKER) SHALL BE MINIMUM YIELD STRENGTH FY = 50KSI, COMPLYING WITH ASTM A653 SS GRADE 50 OR ASTM A1011 SS GRADE 50. STEEL 43 MILS ANDTHINNER, (18 GA AND THINNER) SHALL BE MINIMUM YIELD STRENGTH FY = 33 KSI, COMPLYING WITHASTM A653 SS GRADE 33 OR ASTM A1011 SS GRADE 33, GALVANIZED COATING SHALLCOMPLY WITH ASTM A924.
2. STUD AND TRACK DESIGNATIONS PER STEEL STUD MANUFACTURER'S ASSOCIATION (SSMA), ICC ER-4943P.
3. PROVIDE SECTIONS HAVING PROPERTIES MEETING OR EXCEEDING ABOVE TABULATED GROSS SECTIONPROPERTIES, ICC ER-5912 SECTIONS ACCEPTABLE.
"S" STUD
0.5000 IN FOR W = 1.62 IN0.625 IN FOR W > 2.00 IN
SPECIFIEDFOR THISPROJECT
MEMBERDESIGNATION
DESIGNTHICKNESS IN
REFERENCEGAUGE NO.
SECTIONPROPERTIES
AREA IN 2 Ixx IN 4 Iyy IN 4
* 250S137-54 0.0566 16 0.316 0.318 0.080
400S162-54 0.0566 16 0.433 1.098 0.159
400S200-54 0.0566 16 0.500 1.292 0.287
400S200-68 0.0713 14 0.622 1.581 0.349
400S250-54 0.0566 16 0.566 1.509 0.515
400S250-68 0.0713 14 0.696 1.834 0.630
600S200-33 0.0346 20 0.379 2.075 0.209
600S250-54 0.0566 16 0.670 3.819 0.562
600S250-68 0.0713 14 0.836 4.686 0.688
800S250-54 0.0566 16 0.783 7.465 0.614
800S250-68 0.0713 14 0.976 9.209 0.752
1000S250-68 0.0713 14 1.116 15.683 0.799
1200S250-68 0.0713 14 1.256 24.388 0.836
400T150-33 0.0346 20 0.242 0.622 0.051
400T200-54 0.0566 16 0.452 1.269 0.182
400T200-68 0.0713 14 0.569 1.617 0.227
600T150-33 0.0346 20 .0311 1.590 0.057
600T200-68 0.0713 14 0.712 3.990 0.254
600T200-97 0.1017 12 1.015 5.773 0.354
800T200-68 0.0713 14 0.854 7.786 0.272
800T200-97 0.1017 12 1.218 11.212 0.379
1000T200-68 0.0713 14 0.997 13.292 0.284
1200T200-68 0.0713 14 1.422 19.087 0.397
400Z250-54 0.0566 16 0.566 1.544 1.079
400Z250-68 0.0713 14 0.696 1.819 1.288
600Z250-54 0.0566 16 0.680 3.910 1.079
600Z250-68 0.0713 14 0.836 4.662 1.288
800Z250-54 0.0566 16 0.794 7.628 1.079
800Z250-68 0.0713 14 0.976 9.176 1.289
1000Z250-68 0.0713 14 1.116 15.641 1.289
087F125-27 0.0283 22 0.104 0.013 -
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
"F" FURRINGHAT
CHANNEL
DESIGNATION AS FOLLOWS:
600 S 250 - 54
MATERIAL THICKNESS, "T" (E.G. 54MILS = 0.054 IN)FLANGE WIDTH, "W" (E.G. 250 X1/100 = 2.50 IN)SECTION TYPE (S=STUD, Z=ZEEPURLIN AND T=TRACK)MEMBER DEPTH, "D" (E.G. 600 X1/100 = 6.00 IN)
SCHEDULE (SSMA ER-4943P)
MINIMUM RETURN, TYP.
MATERIAL THICKNESS, TYP.
FLANGE WIDTH
DE
PT
H, T
YP
.
MINIMUM RETURN
2 1/2" MIN
1 1/4".
1/2".
DE
PT
H
CONT MTL TRACK
(2)#10 SDSTS EA CHANNELTO CLIP ANGLE, TYP
METAL STUD
SEE SCHEDULE ON THISSHEET FOR METAL STUD &TRACK SIZES
COLD-ROLLED CHANNELCONT
CLIP ANGLE, DEPTH = 80%OF STUD DEPTH (D)
(2)#10 SDSTS EA CLIPANGLE TO MTL STUD, TYP
DEFLECTION G
AP
1' 6
" M
AX
D
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
5 P
M
S-9.11
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.11
1
FULL HEIGHT CURTAIN WALLDEFLECTION CLIP
SCALE: 3/4" = 1'-0" S-9.11
TYP COLD-FORMED STEEL MEMEBER PROPERTIES 6
SCALE: 3/4" = 1'-0" S-9.11
4
DEFLECTION TRACKASSEMBLY SINGLE TRACK W/COLD - FORMED CHANNEL
K
WF BM EASIDE WHEREOCCURSSEE PLAN
3/8" PL TOP&BOT MIN
CONN PERSCHEDULE
(N) BOLTS PERSCHEDULE TYP
BEAM ONE SIDE
BOLTS PER CONNSCHEDULE (N)
SHEAR PLATE TP PERCONN SCHEDULE
FOR ITEMS NOT SHOWNOR NOTED SEE "BEAMONE SIDE"
NOTES:1. 5/16" MIN FOR COLUMN FLANGES GREATER THAN 3/4" THICK2. PL 1/2" & THICKER SHALL BE GAS OR SAW CUT3. ALL BOLT HOLES SHALL BE STD HOLES UNO.
BEAM TO COL WEB BEAM TO COL FLANGE
WF COL
NOTES:1. USE STANDARD BOLT HOLES2. PROVIDE FULL-DEPTH CONN PL WHENCONNECTING TO LFRS BEAMS
BM PERPLAN
BEAM EACH SIDE
TYP WF BEAM TO WF BEAM
WF BM & GIRDER CONNECTION SCHEDULE
(N)A325N BOLTS
UNOWF BM
(L)MIN PLATE /
WELD LENGTH
(TP)MIN PLATETHICKNESS
(TW)MIN WELD
THICKNESS
W8
W10
W12
W14
W16
W18
W21,24
W27
W30
W33
(2) 3/4"DIA
(2) 3/4"DIA
(3) 1"DIA
(3) 1"DIA
(4) 1"DIA
(5) 1"DIA
(6) 1"DIA
(7) 1"DIA
(8) 1"DIA
(9) 1"DIA
5 1/2"
6"
9"
9"
12"
15"
18"
21"
24"
27"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"2
1/4"
1/4"
1/4"
1/4"
1/4"
3/8"
3/8"
3/8"
3/8"
3/8"
TOP OF COLWHERE OCCURS
ONE-SIDED CONNECTIONOCCURS WHERE OPPOSITEBEAMS ARE OFFSET BY 12"OR MORE
3/8" STIFFENER PLTHIS SIDE WHEREBEAM IS 21" ORDEEPER
BM
EXTEND SHEARPL AT ALL LFRSGIRDERS GIRDER
SEE NOTEBM BOLT & SHEAR PL
PER SCHEDULE
GIRDER
BEAM
NOTE:WHERE NUMBER OF REQUIRED BOLTS PER PLAN ORSCHEDULE ARE MORE THAN NUMBER OF BOLTS THATFIT AT ONE ROW, USE MAXIMUM BOLTS AT FIRST ROW &BALANCE IN SECOND ROW (2 BOLTS MIN AT SECONDROW).
DROP BEAM OR DEEPER BEAM THANGIRDER CONNECTION
CONN PERSCHEDULE
1/2"2
1/2"2
1/2"2
1/2"2
CL BOLTS
3''TYP(TW)
ALLSIDES
TYP PERCONN
SCHED
1 3
/4''M
IN
(TW)
PERSCHED
3''T
YP
1 3
/4''T
YP
2''.
1 3/4''.
1''MAX1/2''MIN
1''MAX1/2''MIN
(TW)
STIFF PLTO CPL
FLANGES& WEB
TYP PERSCHED
(TW)
3 SIDESPER
SCHED
(TW)
ALLSIDES
TYP PERCONN
SCHED K
K
1''MAX1/2''MIN
1/2''CLR
1 3/4'' . . 2''
1 3
/4''M
IN
1 3
/4''M
IN
3''T
YP
1 3
/4''M
IN
3/8" STIFF PLEA SIDE, TYP
COL CAP PL X BMWIDTH" OR COL WIDTH+1/2"C (WHICHEVER ISGREATER) AND SAMETHICKNESSN AS BMFLANGE (3/4" MIN)
NOT ALL ITEMS SHOWNFOR CLARITY
(2) 3/4"DIA A307BOLTS @ STD GA
SHEAR PL TP &BOLTS PERCONNSCHEDULE
COL PER PLANCOL PER PLAN
WF BM PER PLAN
3"
(TW)
2''RETURN
SEECONN
SCHED
3/16TYP
1/4TYP
1 1/2''TYP
1 1/2''TYP
1/2'' .
1 1/2''TYP
1 1/2''TYP
2''.
1 3/4''.
1/2''GAP2'' MIN
PER PLAN
GIRDER,SEE PLAN
BM WHEREOCCURS
# OF 1"DIA. A325SCCLASS "A" BOLTS PERCONN SCHEDULE INEACH ROW
1/2" PL
CL COL
CL COL
BM, SEE PLAN
1/2" PL BMSEE PLAN
# OF 1"DIA. A325SCCLASS "A" BOLTS PERCONN SCHEDULE INEACH ROW
# OF 1"DIA. A325SCCLASS "A" BOLTS PERCONN SCHEDULE INEACH ROW
1/2" PL
BM, SEE PLAN
1/2" PL TOP AND BOT, TYP
BM, SEE PLAN
BM, SEE PLAN
CL COL
3/83 SIDES
3/83 SIDES
TYP1/2''MAX
1/4
WELDSTIFF TO
PL, TOPAND BOT
1/4
3 SIDESWELD PL
TO COL1/4
PL TP COLWEB
TYP1/2''MAX
. 2"
3"TYP1 3/4''TYP
A-A
PLATE &CONN.PERDET.5/S-511
ADDT'L (3)#5 @ 8" O.C.@ A.B. EMBEDMENT
CMU PERPLAN
STL. BEAMPER PLAN
(2) #4
PLATE SCHEDULE
NO. OFBOLTS/SIZE
WF BMPLATE
LENGTH
W12
W16
W18
(4) 3/4"DIA16"
24"
32"
(6) 3/4"DIA
(8) 3/4"DIA
1/2''THK PLATE.NO. OF BOLTSAND LENGTHPER SCHEDULE.
10''.
4''.
8''.
8''.
4''.
A-A
2" MINBEARING TYP.
2" MINBEARING TYP.
4
-
CL PANEL JOINT
CL BEAM
CL BEAM
SEE STEEL BEAM CONN
SCHEDULE
CMU WALL
PL TO CHANNEL3 SIDESTYP.1/4
ELEVATION TYPICAL @ PANEL
SEE PLAN FOR DECKORIENTATION
(2) 3/4"DIAAB TYP.
SPLICE PLATE3/4"X7"X12"
(2) 3/4"DIA AB @ 24" O/CWHEN NO BEAM PRESENT, TYP
(8) 3/4"DIA AB@ FLOORJOIST, TYP
SECTIONA-A
WHEREOCCURS
(2) #4 CONT@ A.B.
COPE TOP ANDBOTTOM FLANGEOF C12X (8" LAG)
WALL OPENING
ELEVATION TYPICAL @ OPENING
CHANNEL SPLICING
WALL OPENING
ELEVATION @ OPENING W/ JOIST
CONT.CHANNELPER PLAN
CL BEAM
(2) 3/4"DIA ABW/ 5" MINEMBED, TYP
CONT CHANNELPER PLAN(4) 3/4"DIA
AB TYP
CONC PERPLAN
TYP6''MIN
TYP
6''MIN
1/4TYP
EQ EQ
10''TYP
8''.
2'0''MAX 8''. 4''. 4''. 8''.8''. 4''. 4''. 8''. 2'0''MAX
2''.
6''.
4''.
8" 8"
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
6 P
M
S-9.12
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.12
TYP BM TO COL AND BM TO BM CONN 1
SCALE: 3/4" = 1'-0" S-9.12
2BM TO TOP OF COLSCALE: 3/4" = 1'-0" S-9.12
BM CONNECTION W/ TWO ROWS OF BOLTS 3
SCALE: 3/4" = 1'-0" S-9.12
4
WF BEAM TO CMU WALLCONNECTION
SCALE: 3/4" = 1'-0" S-9.12S-2.01
BEAM TO CMU CONNECTION 5
STEEL BEAMPER PLAN
1" RADIUSMIN, TYP
CJP TYP
1/2"TYP
SKEWED WF BEAMWHERE OCCURS
WF BEAMWHEREOCCURS
FOR KNIFE PLATE SIZE &BOLTS SEE CONNECTIONSCHEDULE
PERPENDICULAR WF NOTSHOWN FOR CLARITY
WHERE OCCURSCL HSS COL
WHERE OCCURS1/4" CAP PL
1/4
FOR KNIFE PLATE SIZE & BOLTSSEE CONN SCHEDULE
PERPENDICULAR WF NOTSHOWN FOR CLARITY
WF BEAMWHEREOCCURS
CL HSS COL
SEE CONNSCHEDULE
WT4X15.5
WHERE OCCURS
A-A
1/4
B-BA-A
C-C
1/4
WF BEAMWHEREOCCURS
WF BEAMWHEREOCCURS
1/2" MIN1" MAX
1/4
C-C
B-B
A-A
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
6 P
M
S-9.13
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.13
1OPTIONAL SPLICE DETAIL
SCALE: N.T.S.SCALE: 3/4" = 1'-0" S-9.13
TYP BEAM TO HSS COL 2
CHIP OUT CORNER ASREQUIRED FORSQUARE OPENING
CORE 6" DIAMETER HOLEIN EACH CORNER OFOPENING PRIOR TOSAWCUTTING OPENING
EXISTING CONCRETEOR MASONRY
(N) OPENING IN EXISTINGCONCRETE OR MASONRY
SAWCUTOPENING
DO NOT OVER CUT CORNERSSAWCUT ONLY TO COREDHOLES
NON-SHRINKGROUT
DOWELS INTO (E) CMUTO MATCH WALL REBARS
W/ HILTI HIT HY-150 EPOXYW/ SPECIAL INSPECTION TYP
(6" MIN EMBED)
(N) CONCBLOCK TOMATCH (E) WALL
(E) CMU WALL
#5 @ 16" O/C E.W.TYP
Ld TYP
EMBED MIN6''TYP
FIE
LD
ME
AS
UR
E 2''±
2''±
Ld M
IN
16
8LAP
2' - 8"
3
8"
2
7
1
8
8
1' -
0"
8"
6
4
32
7
8
5
7
7
6"
1' -
0"
.
3
1"
CLR
4
6
2
1
6
2
7
88"8"
1" CLR43
SECTION A
SECTION B
SECTION D
SECTION C
B
C
D
C
C
LEGEND
1
2
3
4
5
6
7
8
REMOVE EXISTING WALL BY SAW CUTTING PERIMETER FULL DEPTH
WHERE EXISTING CELLS ARE NOT GROUTED, DRILL HOLES IN(E) WALL AND SOLIDLY GROUT THIS PORTION
DRILL HOLE AND INSTALL #4 DOWEL W/ SIMPSON SET-XP EPOXY
#3 DOWELS @ 16"O/C AT (E) WALL
1 1/2" DRYPACK
GROUT
(E) WALL
(1) #5 CONT
180 DEGREE HOOK W/ 1 1/2" I.D. BEND
OPENING
WALL ELEVATION
SHORE EXISTING ADJACENTCONST. UNTIL 28 DAYS AFTERGROUTING AND DRYPACKINGHAS BEEN PLACED
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
7 P
M
S-9.14
TY
PIC
AL D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.14
1
TYP SAW CUT OPENINGFIGURE
SCALE: 3/4" = 1'-0" S-9.14
3
TYP CMU INFILL AT EXISTINGOPENING
SCALE: 3/4" = 1'-0" S-9.14
TYP CUT OPENING IN CMU WALL 5
FGELEVATION
LONG REINFPER SCHEDULE
TRANSVERSE (SHORT)REINF PER SCHEDULE
#4 BARS SPACING TOMATCH SLAB BAR SPACING
DOWELS TO MATCHWALL VERT. REINF.
WALL REINF.PER PLAN
ROUGHENSURFACE OF
CONCRETE
T.O. S.O.G.ELEVATION
CL OF WALL & FTG
S.O.G, SEE PLANFOR REINF
LAP SPLICE
PE
R S
CH
ED
ULE
FT
G D
EP
TH
TY
P3"
CLR
TYP3" CLR
PER SCHEDULE
FTG WIDTH
18"
MIN
4"
MIN
EQEQ
0".
PER PLANCMU WALL
LONG REINFPER SCHEDULE
TRANSVERSE (SHORT)REINF PER SCHEDULE
#4 BARS SPACING TOMATCH SLAB BAR SPACING
DOWELS TO MATCHWALL VERT. REINF.
WALL REINF.PER PLAN
ROUGHENSURFACE OF
CONCRETE
CL OF WALL & FTG
T.O. S.O.GELEVATION
TYP3" CLR
PER SCHEDULE
FTG WIDTH
EQEQ
0".
PER PLANCMU WALL
PE
R S
CH
ED
ULE
FT
G D
EP
TH
LAP SPLICELd M
IN
S.O.G, SEE PLANFOR REINF
TY
P18"
MIN
METAL STUDPER PLAN
5/8"DIA BOLT@ 24" O.C.
S.O.G.,SEE PLANFOR REINF
T.O. FGELEVATION
T.O. FTGELEVATION SEE PLAN
FOR REINF
(1) #4 CONT.
FINISH PERARCH
3 1/2" TYP6" WHERE RESTROOM
CURB OCCURS
.
TYP3" CLR
TY
P3"
CLR
PER SCHED
FTG WIDTH
PE
R S
CH
ED
FT
G D
EP
TH
18"
MIN
EM
BE
D12"
MIN
SPLICE
LAP
#5 @ 16" O/CHORIZ & VERT
BARS
ROUGHENSURFACE OFCONCRETE
(2) #5 CONTAROUND PIT S.O.G. PER PLAN
12" TYP
24"
TH
K
TY
P3"
CLR
WIDTH PER PLAN
8" CONC WALL
CMU WALL PER PLAN
HSS COLUMN PER PLAN
FINISH FLOOR
A-ASECTION PLAN
REINF. PERSCHEDULE
(4) ANCHOR BOLTSPER SCHEDULE.
A A
COLUMN SIZE
COLUMN SCHEDULE
PLATE SIZE
ANCHOR BOLT
EMBED.SIZE
HSS6x4x1/2" 10"x10"x1" 12"
#4 BARS SPACINGTO MATCH SLABBAR SPACING
FILL W/ CONC. AFTERCOL. ERECTION &ADJUSTMENT
BLOCKOUT PER SLABBLOCKOUT AT COL. DETAILOR PLINTH WHEREOCCURS
WELDSIZE(B)
1/4
SC
HE
D
PE
R
SCHED
PER
1 1/2" TYP
1 1
/2"
TY
P
(B)
SE
E S
CH
ED
ULE
TY
P3"
CLR
TYP3" CLR
PE
R S
CH
ED
EM
BE
D
GRID
3/4" DIA
SEE SCHEDULE
12'' NON-SHRINKGROUT
ALL AROUND1/2''E.J.
11''(
E)S
LA
B
(N)SLAB ON GRADEPER PLAN
REMOVE (E)EQUIPMENT ANDFILL VOID W/CLEAR SAND
WT-OFF PORTIONOF (E)PIT WALLAS SHOWN
(E)UTILITY PIT
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
3/4" = 1'-0"
9/2
8/2
015 1
0:5
8:4
8 P
M
S-9.15
FO
UN
DA
TIO
N D
ET
AIL
S
Designer Author Checker
xxxxxxxx
SCALE: 3/4" = 1'-0" S-9.15S-2.01
1
SECTION AT EXT. CMU WALLFOOTING
SCALE: 3/4" = 1'-0" S-9.15S-2.01
2
SECTION AT INT. CMU WALLFOOTING
SCALE: 3/4" = 1'-0" S-9.15
3
SECTION AT METAL STUDFTG
SCALE: 3/4" = 1'-0" S-9.15S-2.01
4PIT DETAIL
SCALE: 3/4" = 1'-0" S-9.15S-2.01
5HSS COLUMN TO FOOTING
SCALE: 3/4" = 1'-0" S-9.15S-2.04A
6
DETAIL-AIR SUPPLY ATUTILITY PIT
1/4TYP
TYP
1/4" CLOSURE PLT&B
3/4" PL (TYP)
(E) W14X84
STEEL BEAM PER PLAN
1" DRY PACK
SEE ADDT'LREINF. ONELEVATION
NOTE:NO WET SET OFPLATE IS ALLOWED
POCKET SHALL BE SOLIDGROUTED AFTER INSTALL
BEAM WIDTH +4''
3/4'' THK X BEAMWIDTH +2'' X 7''BEAM PL.W/ 5/8''DIA. X 12'' LONGSTUDS@ 4'' O.C.(TOTAL 2 STUDS)
3/16TYP
1/4
1/4
3/16 3
1/2'' STEEL PL. X 7 1/2''WIDE(CONT)W/ 5/8''DIA. X 12 STUDS@16''O.C.
1/8'' THK. X 3''STEEL PL. X 24'' LONG3/16'' FILLET WELD TO TOP PLATE
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
As indicated
9/2
8/2
015 1
0:5
8:4
8 P
M
S-9.17
FR
AM
ING
DE
TA
ILS
Designer Author Checker
xxxxxxxx
SCALE: 1 1/2" = 1'-0" S-9.17S-3.04
1COLUMN REINFORCEMENT
SCALE: 3/4" = 1'-0" S-9.17S-2.01
2DETAIL
(E)W33X141 AT 40'-0''OC
SUSPENTION FITTINGTOP AND BOTTOM(BY CRANE SUPPLIER)
SUSPENTION FITTINGTOP AND BOTTOM(BY CRANE SUPPLIER)
RUNWAY TRACK BEAM
SPLICE ANGLES ANDPLATES AS REQ(BY CRANE SUPPLIER)
LONGITUDINAL SWAYBRACING AT 12'0''OCOCNNECTED TO TOPFLANGE OF (E) W33(BY CRANE SUPPLIER)
B-B
FLECIBLE SUPPORT FORRUNWAY TRACK BEAMAT 40' SPACING(BY CRANE SUPPLIER)
CL SPLICE ANDW33 GIRDER ABOVEAT 40' SPACING
B - B
BEAM STIFFNERSAS REQUIRED(BY CRANE SUPPLIER)
SUSPENTION FITTINGTOP AND BOTTOM(BY CRANE SUPPLIER)
FLECIBLE SUPPORT FORRUNWAY TRACK BEAMAT 40' SPACING(BY CRANE SUPPLIER)
SUSPENTION FITTINGTOP AND BOTTOM(BY CRANE SUPPLIER)
RUNWAY TRACK BEAM(BY CRANE SUPPLIER)
VIEW A - A
A-A
LATERAL SWAY BRACING(BY CRABE SUPPLIER)FOR RUNWAY TRACK BMCONNECTED TO (E)W33 BM AT 40'0''OC
1
1
1
1
1
1
(E) W33X141BOTTOM FLANGE
2MAX
1
B-B
A-A
VIEW B-B
1111
CCCC
BBBB
AAAA
55554444333322221111
DDDD
5555444433332222
-
FDYD1740
NA
VA
L F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
SW
DIV
ISIO
N
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
A/E INFO
DE
PA
RT
ME
NT
OF
TH
E N
AV
YN
AV
AL F
AC
ILIT
IES
EN
GIN
EE
RIN
G C
OM
MA
ND
CO
AS
TA
L IP
TN
AV
AL B
AS
E V
EN
TU
RA
CO
UN
TY
- P
OIN
T M
UG
U, C
A
NA
VA
L B
AS
E V
EN
TU
RA
CO
UN
TY
PO
INT
MU
GU
, CA
SD
60% DESIGNDEVELOPMENT SUBMITTAL
SY
MD
ES
CR
IPT
ION
DA
TE
AP
PR
E-2
C/D
HA
NG
AR
AD
DIT
ION
S A
ND
RE
NO
VA
TIO
NS
SEAL
--
--
#
3161 Michelson Drive, Suite 500Irvine, CA 92612(949) 224-7500
FAX (949) 224-7501
60
% D
ES
IG
N D
EV
ELO
PM
EN
T S
UB
MIT
TA
L - 2
OC
TO
BE
R 2
01
5V
&Y
Pro
ject N
o.: B
124-1
290
1" = 1'-0"
9/2
8/2
015 1
0:5
8:4
8 P
M
S-9.20
CR
AN
E D
ET
AIL
Designer Author Checker
xxxxxxxx
SCALE: N.T.S. S-9.20