M cKenney’s provided critical services that enabled HVAC systems to remain online during a chiller plant renovation for the commercial office in Atlanta, Georgia. THE CHALLENGE The McKenney’s team needed to ensure optimal uptime of an HVAC chilled water system as old equipment was removed and new chillers and pumps were installed. Also, the plant’s layout did not allow removal and installation of the equipment intact— requiring demolition of several concrete walls, doorways and a rest room. THE SOLUTION The original engineering design would have cause a prolonged shutdown of the HVAC system. McKenney’s design/assist services recommended an alternative. Instead, the team used alternate pumps and chiller piping configurations to maintain 800 tons of cooling operation at all times during the renovation. To overcome facility space limitations, existing systems were dismantled and removed, and new chillers were disassembled and then reassembled in the plant’s mechanical room. THE RESULTS The project was completed safely, on time and on budget with just one eight-hour HVAC outage to complete the chiller installation. Designing Alternatives for Uptime PROJECT NAME John Hancock 1100 Peachtree Street Chiller Plant Renovation PROJECT LOCATION Atlanta, Georgia PROJECT TEAM Owner: John Hancock Engineer: Barrett, Woodyard & Associates, Inc. Contractor: McKenney’s, Inc. SPECIALIZATIONS Design/Assist bdoc Pipe Shop Prefab MARKETS Mission Critical Commercial Offices The content of this document is not intended as an endorsement. www.mckenneys.com © 2014 McKenney’s, Inc., Atlanta, Georgia. All rights reserved. Printed in the U.S.A. McKenney’s, Inc. and the McKenney’s, Inc. logo are registered trademarks of McKenney’s, Inc. All other trademarks are the property of their respective owners. 404-622-5000 [email protected] 1056 Moreland Industrial Boulevard Atlanta, Georgia 30316 704-357-1200 [email protected] 3601 Performance Road Charlotte, North Carolina 28214

Upload: mckenneys-inc

Post on 25-Jun-2015

32 views

Category:

Business


1 download

DESCRIPTION

McKenney’s provided critical services that enabled HVAC systems to remain online during a chiller plant renovation for the commercial office in Atlanta, Georgia.

TRANSCRIPT

Page 1: Designing Alternatives for Uptime - Chiller Plant Renovation

McKenney’s provided critical services that enabled HVAC systems to remain online

during a chiller plant renovation for the commercial office in Atlanta, Georgia.

THE CHALLENGEThe McKenney’s team needed to ensure optimal uptime of an HVAC chilled water system as old equipment was removed and new chillers and pumps were installed.

Also, the plant’s layout did not allow removal and installation of the equipment intact—requiring demolition of several concrete walls, doorways and a rest room.

THE SOLUTIONThe original engineering design would have cause a prolonged shutdown of the HVAC system. McKenney’s design/assist services recommended an alternative. Instead, the team used alternate pumps and chiller piping

configurations to maintain 800 tons of cooling operation at all times during the renovation. To overcome facility space limitations, existing systems were dismantled and removed, and new chillers were disassembled and then reassembled in the plant’s mechanical room.

THE RESULTSThe project was completed safely, on time and on budget with just one eight-hour HVAC outage to complete the chiller installation.

Designing Alternatives for UptimePROJECT NAME

� John Hancock 1100 Peachtree Street Chiller Plant Renovation

PROJECT LOCATION

� Atlanta, Georgia

PROJECT TEAM

� Owner: John Hancock

� Engineer: Barrett, Woodyard & Associates, Inc.

� Contractor: McKenney’s, Inc.

SPECIALIZATIONS

Design/Assist

bdoc

Pipe Shop Prefab

MARKETS

� Mission Critical

� Commercial Offices

The content of this document is not intended as an endorsement.

www.mckenneys.com© 2014 McKenney’s, Inc., Atlanta, Georgia. All rights reserved. Printed in the U.S.A.

McKenney’s, Inc. and the McKenney’s, Inc. logo are registered trademarks of McKenney’s, Inc. All other trademarks are the property of their respective owners.

404-622-5000 [email protected] 1056 Moreland Industrial Boulevard Atlanta, Georgia 30316

704-357-1200 [email protected]

3601 Performance Road Charlotte, North Carolina 28214