determination of safety-relevant data of ferro niobium · temperature of the oven was increased to...
TRANSCRIPT
Page 1 of 12
A company of Bayer and LANXESS
STUDY TITLE
Determination of Safety-Relevant Data of
Ferro Niobium
SPONSOR
CBMM Europe BV WTC H-tower Zuidplein 96
1077 XV Amsterdam The Netherlands
DATA REQUIREMENT
EC-Regulations A 16 (Relative Self-Ignition Temperature)
STUDY DIRECTOR
H. - P. Keldenich
STUDY COMPLETION DATE
2009-10-21
TEST FACILITY
Currenta GmbH & Co. OHG Safety / Process and Plant Safety
Safety Laboratory D-51368 Leverkusen
Federal Republic of Germany
LABORATORY PROJECT ID
Study No. 2009/01120
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 2 of 12
This page is intentionally left blank for the purpose of submitting administrative information that is required by regulations promulgated by various countries.
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 4 of 12
GLP-CERTIFICATE The test facility 'Bayer Industry Services GmbH & Co OHG' trades since 1st January 2008 under the name 'Currenta GmbH & CO OHG'.
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 5 of 12
VALIDITY OF THE GLP-CERTIFICATE AFTER RENAMING (PART 1 OF 2)
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 6 of 12
VALIDITY OF THE GLP-CERTIFICATE AFTER RENAMING (PART 2 OF 2)
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 7 of 12
This page is intentionally left blank for the purpose of submitting administrative information that is required by regulations promulgated by various countries.
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 8 of 12
Table of Contents Page
Study Title................................................................................................................................ 1
Sponsor ................................................................................................................................... 1
Data Requirement.................................................................................................................... 1
Study Director .......................................................................................................................... 1
Study Completion Date............................................................................................................ 1
Test Facility ............................................................................................................................. 1
Laboratory Project ID............................................................................................................... 1
GLP Compliance Statement .................................................................................................... 3
Certification of Authenticity ...................................................................................................... 3
Study Director .......................................................................................................................... 3
Archiving.................................................................................................................................. 3
Quality Assurance Statement .................................................................................................. 3
Quality Assurance Unit ............................................................................................................ 3
GLP-Certificate ........................................................................................................................ 4
Validity of the GLP-Certificate after renaming (Part 1 of 2)...................................................... 5
Validity of the GLP-Certificate after renaming (Part 2 of 2)...................................................... 6
Summary of Results ................................................................................................................ 9
Test Substance...................................................................................................................... 10
Reference Substance ............................................................................................................ 10
General Study Information..................................................................................................... 10
Sponsor ................................................................................................................................. 10
Monitor................................................................................................................................... 11
Sponsors Contact .................................................................................................................. 11
Test Facility ........................................................................................................................... 11
Experimental.......................................................................................................................... 12
1. Relative Self-Ignition Temperature for Solids .................................................................. 12
Enclosure 1............................................................Graph of the Relative Spontaneous Ignition
Enclosure 2......................... Validity of the GLP-Certificate after renaming (english translation)
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 9 of 12
SUMMARY OF RESULTS
Determination of Safety-Relevant Data of
Ferro Niobium
Used test guideline: Guideline 92/69/EWG (German) 'Methods for Determination of Physicochemical Property' Official gazette No L 383 A of December 1992
Point Study-point Method Result
1 Relative Self-Ignition Temperature for Solids EC-A 16 does not undergo spontaneous
combustion
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 10 of 12
TEST SUBSTANCE
Test item: Ferro Niobium AD-number: 4204 CUR internal sample number: 106203 Physical condition: rough pieces Storage: room temperature
MAIN ELEMENTS Component: Ferro CAS number: 7439-89-6 Analysis: 29.4 % Component: Niobium CAS number: 7440-03-1 Analysis: 65.9 % A copy of 'Certificate of Analysis' (Companhia Brasileira de Metalurgia e Mineracao, 2009-07-07) is present in CUR-SIC-VA-VSC and was archived. No repeat identity test was performed in the VA-VSC Laboratory.
REFERENCE SUBSTANCE No reference substances were employed for the tests.
GENERAL STUDY INFORMATION
Sample arrival date: 2009-08-18
Date of study plan: 2009-08-18
Experimental start: 2009-08-21
Experimental finish: 2009-08-22
Report finalization: 2009-10-05
Author of final GLP report: H.- P. Keldenich
SPONSOR Name / Address: CBMM Europe BV
WTC H-tower Zuidplein 96 1077 XV Amsterdam The Netherlands
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 11 of 12
MONITOR Name / Address: CBMM
Companhia Brasileira de Metalurgia e Mineracao Mr Jorge Davo Còrrego da Mata s/n 38183-903 Araxà – MG Brasil
SPONSORS CONTACT Name / Address: BSL BIOSERVICE Scientific Laboratories
GmbH Behringstr. 6/8 82152 Planegg/Munich Germany
TEST FACILITY Name / Address: Currenta GmbH & Co. OHG
Safety / Process and Plant Safety Safety Laboratory Building B 407 D-51368 Leverkusen Federal Republic of Germany
Telephone: +49 214 30 618 17 Telefax: +49 214 30 552 28 Email-Address: [email protected]
Currenta GmbH & Co. OHG Study No.: 2009/01120
Page 12 of 12
EXPERIMENTAL 1. Relative Self-Ignition Temperature for Solids The test was performed as stipulated in EC Test Procedure A 16 'Relative Self-Ignition Temperature for Solids'. 8 ml of the substance (coarsely grounded) was filled in a stainless steel wire mesh (0.045 mm openings, dimensions of 2 x 2 x 2 cm) and placed in a 2-litre-oven (self-build) at room temperature. The oven was operated with natural air circulation. For the controlling of the oven temperature an eurotherm-controller type ‘818 P’ was used and for recording of all temperatures Fe-CuNi-Thermocouples (type L) were used. The temperature/time curve relating to conditions in the centre of the sample was electronically recorded (software FIX32) while the temperature of the oven was increased to 410 °C at a rate of 0.5 °C/min. For this purpose, the temperature of the oven at which the sample temperature reached 400 °C by self-heating is called the self-ignition temperature. No exothermic effects were determined up to 410 °C. A copy of the recorder trace is attached (see Graph of the Relative Spontaneous Ignition). ‘Ferro Niobium' is classified as not undergoing spontaneous combustion when tested according to EC Test Procedure A 16.
SI Process and Plant Safety
500
450
400
350
300
250
200
150
100
50
0
Temperature in °C
0000:00:00 0002:00:00 0004:00:00 0006:00:00 0008:00:00 0010:00:00 0012:00:00 0014:00:00 0016:00:00
Time in hhhh:mm:ss
1.
2.
Determination of the Relative Spontaneous Ignition Temperature (EC-A16)
Report No. 2009/01120VA-internal Sample No. 106203Test Substance Ferro NiobiumTemperature Rate 0.5 K/minTest Volume 8 mLEnclosure 1 of 2Date 2009-08-25Tester Colianni
This Diagram is not the original. The figures are based on original plotter diagram.
1. Sample temperature2. Oven temperature
1.
2.
Transla
tion f
or Inf
ormati
on
Ministry of Labor,
Health and Social Affairs
of North Rhine-Westphalia
Enclosure 2 of 2 to report 2009/01120
Date: 18.12.2007 Ministry of Labor, Health and Social Affairs of North Rhine-Westphalia, 40190 Düsseldorf Currenta GmbH & Co. OHG Page 1 of 2 SIC-VA-VSC Prüfeinrichtung "Sicherheitstechnisches Laboratorium" Reference II A 5 – 31.11 Gebäude B 407 Please indicate in any Chempark
correspondence
Sabine Börner
Phone 0211 855-3335
Fax 0211 855-3705
D-51368 Leverkusen Validity of the GLP certificate dated July 13, 2005 owing to your change of name
Office building and delivery
address:
Fürstenwall 25,
40219 Düsseldorf
Phone 0211 855-5
Fax 0211 855-3683
Your mail dated December 17, 2007 Ladies and gentlemen, From February 22 to 23, 2005, an inspection was carried out by a team of inspectors from North Rhine-Westphalia in the above testing facility to check compliance with the principles of Good Laboratory Practice in accordance with Annex 1 of the German Chemicals Act (in the version in the notification dated June 20, 2002). As you stated in your mail dated December 17, 2007, the name of your company will change from January 1, 2008. According to your mail, the legal form (GmbH & Co. OHG), the ownership structure (Bayer/LANXESS), the areas of operation and the organizational structure will remain unchanged, this also applying to the GLP testing facility of the “Sicherheitstechnisches Laboratorium” (Technical Safety Laboratory). The new name of the testing facility will be: Currenta GmbH & Co. OHG SIC-VA-VSC Prüfeinrichtung "Sicherheitstechnisches Laboratorium"
www.mags.nrw.deGebäude B 407
Public transport:
Rheinbahn lines 704, 709
Stop: Stadttor
Rheinbahn lines 719,725
Stop: Polizeipräsidium
Chempark D-51368 Leverkusen The GLP certificate dated July 13, 2005 assigned to Bayer Industry Services GmbH & Co OHG; Prüfeinrichtung SUA-VA 1; Gebäude B 407; D-51368 Leverkusen