Page 1: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

Revision 006

November 2018

DDDeeevvviiiccceeeXXXPPPlllooorrreeerrr DDDaaatttaaa LLLoooggggggeeerrr User’s Guide

Page 2: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 2 -

[ Precautions regarding this manual ] (1) Read this manual and understand it thoroughly before operating the product. (2) This manual explains the details of the product’s functions; it does not guarantee that the product is suitable for

your particular purposes. (3) Publishing or copying this manual or any part thereof without permission is strictly prohibited. (4) The content of this manual is subject to change without notice. (5) The content of this manual applies to program versions 2.1.2.1 or higher. [ Product liability ] (1) TAKEBISHI provides no guarantee for this product other than in the situations stipulated in the Warranty

Conditions. (2) TAKEBISHI also disclaims liability for any damage incurred by the customer or a third party when using the

product or when there are unforeseeable defects in the product or any indirect damages. [ About the software ] (1) Use this software installed on one particular PC.

Another separate license is required to install and use the software on another PC. (2) Copying the software for purposes other than backup is strictly prohibited. (3) Carefully store the CD (media) that contains the software. (4) Reverse engineering of the software, such as decompiling and disassembly, is strictly prohibited. (5) It is strictly prohibited to allow a third party to use this software, or any portion of it, through transfer, exchange or

subleasing, etc., without the prior consent of TAKEBISHI. (6) The specifications of the software are subject to change without notice. [Copyrights ] TAKEBISHI Corporation holds the copyrights to the programs contained in the CD, the online manual, and other documentation. It is prohibited to copy this content or to transfer, sell, or distribute (including providing it via PC network) to a third party. It is also prohibited to record the content, using video tape or other media, without permission. [ Trademarks ] All company names, product names and trademarks that appear in this manual are trademarks of their respective owners.

Page 3: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 3 -

1 Introduction .................................................................................................................................................................................. - 5 -

1.1 Overview .............................................................................................................................................................................. - 5 - 1.2 Features ............................................................................................................................................................................... - 5 -

2 Configuration ............................................................................................................................................................................... - 6 - 2.1 System Configuration ....................................................................................................................................................... - 6 - 2.2 Operating Environment ................................................................................................................................................... - 7 - 2.3 Necessary Software ........................................................................................................................................................... - 7 -

3 Install ............................................................................................................................................................................................. - 8 - 3.1 Install Procedure ................................................................................................................................................................ - 8 - 3.2 Installation Files .............................................................................................................................................................. - 11 - 3.3 Uninstall Procedure ........................................................................................................................................................ - 11 - 3.4 License Authorization ..................................................................................................................................................... - 12 -

3.4.1 Serial Number ......................................................................................................................................................... - 12 - 3.4.2 Software Key (License Code) ................................................................................................................................ - 12 - 3.4.3 License Activation ................................................................................................................................................... - 12 - 3.4.4 License Transfer...................................................................................................................................................... - 13 - 3.4.5 License Clear ........................................................................................................................................................... - 15 - 3.4.6 License Status and Application Operation ........................................................................................................ - 16 -

3.5 Demo version .................................................................................................................................................................... - 16 - 4 General Performance Specifications ...................................................................................................................................... - 17 -

4.1 Specifications Table ......................................................................................................................................................... - 17 - 4.2 Corresponding OPC interface ....................................................................................................................................... - 20 -

5 Operation .................................................................................................................................................................................... - 21 - 5.1 Screen layout .................................................................................................................................................................... - 21 -

5.1.1 The entire screen .................................................................................................................................................... - 21 - 5.1.2 Menu ......................................................................................................................................................................... - 21 - 5.1.3 Tool bar ..................................................................................................................................................................... - 23 - 5.1.4 Explorer view........................................................................................................................................................... - 24 - 5.1.5 Setting window ....................................................................................................................................................... - 25 - 5.1.6 Log message view ................................................................................................................................................... - 27 - 5.1.7 Diagnostic view ....................................................................................................................................................... - 27 - 5.1.8 Status bar ................................................................................................................................................................. - 27 -

5.2 Tutorial ............................................................................................................................................................................... - 28 - 5.2.1 Install DxpLOGGER ............................................................................................................................................. - 28 - 5.2.2 Setting OPC server ................................................................................................................................................ - 28 - 5.2.3 Start up DxpLOGGER .......................................................................................................................................... - 28 - 5.2.4 License activation of DxpLOGGER .................................................................................................................... - 29 - 5.2.5 Basic setting of DxpLOGGER ............................................................................................................................. - 29 - 5.2.6 Start up preject wizard .......................................................................................................................................... - 30 -

5.2.6.1 Communication setting .................................................................................................................................... - 32 - 5.2.6.2 Tag setting ........................................................................................................................................................... - 32 - 5.2.6.3 Setting contents selection ................................................................................................................................. - 33 - 5.2.6.4 Periodic logging .................................................................................................................................................. - 34 - 5.2.6.5 Logging in accordance with the event ............................................................................................................ - 36 - 5.2.6.6 Alarm monitoring .............................................................................................................................................. - 38 - 5.2.6.7 User program execution and Periodic writing ............................................................................................. - 40 -

5.2.7 Save setting file ....................................................................................................................................................... - 42 - 5.2.8 Run Group ............................................................................................................................................................... - 42 - 5.2.9 Logging Data View ................................................................................................................................................. - 43 - 5.2.10 Viewing Histrical Trend Graph ........................................................................................................................... - 44 -

Page 4: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 4 -

5.2.11 Viewing Realtime Trend graph ............................................................................................................................ - 45 - 5.2.12 Viewing currently Alarm ....................................................................................................................................... - 46 - 5.2.13 Viewing Alarm History .......................................................................................................................................... - 46 - 5.2.14 Stop Group ............................................................................................................................................................... - 47 -

6 Troubleshooting ......................................................................................................................................................................... - 48 - 6.1 Error Messages ................................................................................................................................................................ - 48 -

7 Appendix ..................................................................................................................................................................................... - 50 - 7.1 Copyright Information .................................................................................................................................................... - 50 - 7.2 User Support..................................................................................................................................................................... - 50 -

Page 5: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 5 -

1 Introduction This manual explains how to use DeviceXPlorer Data Logger(hereafter referred to as DxpLOGGER). For information of OPC server, setting with PLC and operating method, refer to each User’s Guide.

1.1 Overview DxpLOGGER is data logging and monitoring alarm software for OPC. Function of data logging, alarm monitoring and trend graph display is supported. It can be used for various fields, such as data collecting system, alarm monitoring system and so on.

1.2 Features - Use of OPC(Supported OPCUA,OPCDA2.05) OPC is standard interface specification for communication, so you can access to the data of cominicated equipment for OPC server (PLC, measuring hardware). High flexible system can be constructible which does not depend on the hardware. - Supports a variety of database Collecting data or monitoring alarm history, DxpLOGGER is able to store to various dtabases not only CSV due to supporting access of database through ODBC. Collecting data to database, MES can work together. DxpLOGGER bufferes gathering data in local disk and loss of dta can be maximally suppressed if connection to the storage location is lost. - Data logging DxpLOGGER provides “Periodic Logging” and “Event logging”. Intervals can be set in a wide range from 50 milliseconds at the fastest to 24 hours. Maximum 512 points can be collected per group. 128 group at most can be made and logging dta 65,536 points (512 ×

128) maximum for both “Periodic Logging` ̀and “Event logging”. For collecting data, calculations as below and various logging are available. *Enginnering value conversion *Multiplying factor calculation to convert over the multiplying factor to pulse value *BCD conversion to BIN *Character string log to convert numbers to character table *Logarithm logging *Logging for amount of change (constantly integrating pulse value) *Square root extraction *Power factor caluculation *Specifying rate-of-change for logging in case of exceeding the rate

- Alarm monitor DxpLOGGER enable to monitor alarm with comparing conditions between each specified value or data. (>,≧,=,≠,≦,<) Replace from existing alarm monitor system can be made easily due to supported combination of 2 conditions (AND/OR). Maximum 1024 points per group, 131,072 points (1024×128)of alarm can be monitored. Monitoring intervals can be set felexibility from the fastest 50 millisecond to 24 hours.

- Data display Logging data is displayed as spread sheet like Excel. Data can be found easily with specifying data of calendar. Data

Page 6: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 6 -

between more than one date/file can be confirmed at once.

- Trend graph display Logging data can be displayed as graph. DxpLOGGER supports historical trend for event collecting and real time trend for current collecting. Any area can be enlarged and each item can be switched. Maximum 16 graphs can be displayed at once.

- Action DxpLOGGER execute custom logic per specified time or intervals and writing various process, such as heartbeat signal, value of increment, decrement, fixed and time. Value of tag also can be written to another tag.

- Various sub-function DxpLOGGER features sub-function as below. -Auto-execute feature of logging on start-up -Check-up feature of current logging or monitoring status -Security features that can limit the operation function for each user.

2 Configuration

2.1 System Configuration DxpLOGGER system configuration is as shown below.

-A single server supports multiple PLCs. -Remote connection from a separate node to OPC server possible -Whether local PC or remote, destination of data can be specified.

Page 7: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 7 -

Point Appropriate DCOM settings for connecting PC for OPC server and DxpLOGGER via OPC DA are needed to remote connection (DCOM) to OPC server.

2.2 Operating Environment DxpLOGGER operates in the following environments:

Item Description Computer Computer running Windows

OS*1 Windows10 vesion1607/ Windows8.1/ Windows8/ Windows 7 / Windows Vista / Windows Server2012(R2)/ Windows Server 2008(R2) Japanese OS and English OS

Application Type 32 bit application (WIN32 / x86) Memory 1GB or more Processor 1GHz or more Hard disk 20MB or more*2 Framework .NET Framework 4.0 or more Display resolution XGA(1024×768)or more Disc device CD-ROM drive

*1 DxpLOGGER run as 32bit application, on 64bit operate system. *2 Installing disk space for .NET Framework 4.0 and harddisk disk for collecting data is needed. 2GB or more is

recommended.

2.3 Necessary Software Necessary software to install DxpLOGGER is as follows.

項目 内容 備考

OPC Server Correcponded OPC-UA and OPC-DA2.05A 【Recommended Product】 TAKEBISHI OPC Server (DeviceXPlorer OPC Server)

ODBC data base and ODBC driver

Microsoft SQL Server 2012 (2008) ODBC driver:SQL Server

Necessary when ODBC is selected for storage.

Microsoft Access 2007 ODBC driver:Microsoft Access Driver Oracle Database 11g ODBC driver:Oracle in OraClient11g_home1 PostgreSQL 9 ODBC driver:PosgreSQL ODBC driver

Excel Microsoft Office Excel 2013/ 2010 / 2007 / 2003 Necessary to display excel file.

Page 8: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 8 -

3 Install

3.1 Install Procedure (1) Inserting the product CD in the drive lanches the installer. Choose setup language in dialog. Important You must have Administrator rights to set up.

(2) Depending on the environment to install, install necessary component for DxpLOGGER Click to Install. (3) When the InstallShield is displayed, press “Next.”

Page 9: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 9 -

(4) If you agree with the License Agreement, press “Yes.”

(5) Enter user information and press”Next.”

(6) Select folder to store.

Page 10: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 10 -

(7) Preparation for installation is not Finishd. Press ‘’Install’’ to start installation.

(8) When the Windows component is updated, it is necessary to restart PC.

Page 11: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 11 -

3.2 Installation Files DxpLOGGER installation sets up the following files.

内容 セットアップパス 備考 DxpLOGGER Installation folder ¥Bin Application file and so on. User’s guide Installation folder ¥Doc

Tool Installation folder ¥Tool SuperLOGGERConvertor RemoteLOGGERConvertor

OPC-DA components Windows system folder OPC-DA RCW interface OPC-UA components Installation folder ¥Bin OPC-UA interface

Windows components Windows system folder .NET Framwork4.0 VC# runtime library

3.3 Uninstall Procedure You can uninstall DxpLOGGER by following the steps below. (1) Stop the operation of DxpLOGGER and quit DxpLOGGER. (2) In the Control Panel, select “Add/Remove Program”

(3) Uninstall DeviceXPlorer Data Logger. (4) Even after DxpLOGGER has been uninstalled, project data created by the user will remain. If you do not need the

data, delete it along with the installation folder.

Page 12: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 12 -

3.4 License Authorization License authorization is necessary in order to operate the product as a genuine product.

3.4.1 Serial Number The serial number is a unique number that you receive when you purchase a product. When installing the product, you need to enter the serial number accurately. Important DxpLOGGER can be installed one license each PC. If you need to install to several PC, you need license for each PC.

3.4.2 Software Key (License Code) If your product requires a software key, you need to install the serial number and the software key onto the same PC in order to run the product. When you install the product, enter the correct serial number. And when you activate license, enter the correct license code you got from us. For getting license code, please refer “License Status and Application Operation”. Important You need to obtain a license code within 14 days. Obtain a license code by one of the following methods. 1. Website On the user registration page of the TAKEBISHI website, enter your serial number, computer ID, and other required information and submit it. You will receive a response with your license code. URL http://www.faweb.net/asp/registration.aspx 2. FAX Write your serial number, computer ID and other required information on the user registration form and fax it to TAKEBISHI. You will receive a response with your license code. Fax number 075-325-2273 If you can't get a license cord after the above application procedures, please contact us to the following email address. Email address: [email protected]

3.4.3 License Activation Click ‘’License’’ in the ‘’Help’’ menu and display license entry window. Enter your serial number and click ‘’Activate’’.

Page 13: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 13 -

License will authenticated like the following . If you enter wrong serial number, following message will be appeared.

3.4.4 License Transfer You can transfer the license from the PC which license is installed in to other PC. License Transfer will be enable you to check the system on debugging PC and to shift the official PC easily. 1. At first, you install DeviceXPlorer in the PC of the forwarding address and confirm computer ID.

Important Please authenticate the license until the expiration date.

2. Next, you select “Transfer License” from right-click menu of the component at the original PC..

Page 14: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 14 -

3. You fill out computer ID that you got at “1” at the window.

4. If you click “Transfer License” button, you will get a new license code for other PC.

Important When you do license transfer, original PC's license becomes invalid.

Note The License Code is stored in “LicensTransferred.txt” in current path.

5. Finally you install the license code that you acquired at 4. in a forwarding address PC, and the transfer of the

license is Finishd.

Page 15: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 15 -

3.4.5 License Clear When license is authorized, click ‘’Deactivate’’ and license authorization is cleared.

Following message is apeared if succeeded.

Important License Authorization needs ‘’Administrator’’ user of DxpLOGGER.

・When UAC is valid and not to run as ‘Administrator’, following message is appeared. Retry to run as ‘Administrator’ and authorize license. 【failure to authorize】

【failure to clear Authorization】

Page 16: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 16 -

3.4.6 License Status and Application Operation The correspondences between license status and application operation are as shown below.

License status Application operation Product version No restriction Temporary license No restriction till temporary license expiration. Demo version Operates in demo mode for 1 hour. Operation stops after 1 hour.

Demo version(Stop) Operates in demo mode for one hour and stops. Restart is required to continue to use.

License status is displayed on status bar at the bottom right of the application.

3.5 Demo version If you do not authorize license, it operates as demo version. There is no restriction in demo version but it runs for only one hour.

Page 17: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 17 -

4 General Performance Specifications

4.1 Specifications Table 項目 内容

Connectable OPC server 128 pcs Communication interface OPC-UA,OPC-DA2.05A (see more details to ‘’4.2’’) OPC UA protocol TCP OPC browse function Acquisition of server list, access path OPC data acquisition system Data change notification / cache read / device read

Suport data type *1

VT_BOOL Boolean type VT_I1 8-bit signed integer type VT_UI1 8-bit unsigned integer type VT_I2 16-bit signed integer type VT_UI2 16-bit unsigned integer type VT_I4 32-bit signed integer type VT_UI4 32-bit unsigned integer type VT_R4 32-bit signed real type VT_I8 64-bit signed integer type VT_UI8 64-bit unsigned integer type VT_R8 64-bit signed real type VT_BSTR character string type

OPC delimiter symbol Available to change to any symbol in communication settings. Dot symbol (.) by default.

Communication error data management *2

[NULL value], [Keep previous value], [Zero(0)] can be seleccted

Saving data

CSVfile Various database through ODBC (Microsoft SQL Server 2012(2008) / Microsoft Access 2007 / Oracle Database 11g / PostgreSQL)

Disk write cache function Specified by number, KB

Offline buffering function During disconnecting to distination, 30,000 data can be buffered to local at most.

Item management Item management by tag Alias can be defined for OPC item. (maximum 128 characters)

Auto-execution Available

User authority Registration of 10 users at most. /Restriction of operating items by users. User name and password can be set optionally. (maximum 128 characters )

Start-up user specified Available Start-up file specified Available Store at task tray Available to store at task tray on minimizing Message log auto-save Switching propriety of save on basic setting Numbers of log to be displayed From 100 to 100,000 can be set.

Calculation for tag

Engineering value conversion

All data excluding VT_BOOL and VT_BSTR

Power factor All data excluding VT_BOOL and VT_BSTR

Square root extraction

All data excluding VT_BOOL and VT_BSTR

Page 18: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 18 -

Multiplying factor caluculation

All data excluding VT_BSTR

Number of significant figures

All data excluding VT_BOOL and VT_BSTR

BCD conversion VT_I1 / VT_UI1 / VT_I2 / VT_UI2 / VT_I4 / VT_UI4 Logging for amount of change

VT_I1 / VT_UI1 / VT_I2 / VT_UI2 / VT_I4 / VT_UI4

Logarithm logging VT_I4 / VT_UI4 Change rate specified

All data excluding VT_BOOL and VT_BSTR

String table VT_I1 / VT_UI1 / VT_I2 / VT_UI2 / VT_I4 / VT_UI4 Collecting method periodic logging, event logging

Data collection

Collecting period from 50milisecond to 24 hours Data point 65,536 points each system(maximum 512 points x 128 groups) Collecting method hour record, relative time log, data change log Data logging during stopping

Available

Saving format CSV,ODBC

Slip function Daily / monthly / annual report for only CSV(Total, average, maximum, minimum) output support

Triggering condition Specified execution condition

Save file split (CSV files only) Split setting is available depending on logging numbers, time, period, trigger conditions, collection srart.

Format setting Available any format setting (Time field is necessary)

The maximum number of fields

513(Including one time field)

Data display spread sheet External output CSV, Excell Display method Real time trend, Historical trend

Graph function

Real time trend Able to display from 50 miliseconds to 1 minute. ( plot 5 to10,000 points per line)

Historical trend Plot points, maximum 10,240,000 points Graph types XY plot, step chart, area chart, bar graph, semi-logarithmic graph Read method Calendar format, file specification Operation Time axis, Y-axis Number of graph 16 Number of line 512 Number of color Any (available to specified by RGB.) Maker 2 markers (able to switch display) Caluculation between markers

Average, maximum, minimum

Anti-aliasing display Switchable Search Maximum value, minimum value, specified value Display Optimize, side by side External output Printer print, image output, file output Other Selected row highlighting, grid display, symbol display, legend display Triggering condition Specified execution condition

Alarm Period From 50 miliseconds to 24 hours

Page 19: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 19 -

monitor Point 131,072 points (maximum 1024 points x 128 groups) Conditions Comparison between tag data and value, comparison of each tag data Number of setting 2 conditions (AND/OR logical conditions) Comparison conditions

>,≧,=,≠,≦,<

Display method Alam summary, alarm history

Alarm serch function date and time of occurrence of the alarm/recovery, alarm comment, alarm level

Alam summary Filtering by group name and alarm level Alarm history Display as spread sheet Saving format CSV,ODBC Triggering condition Specified execution condition

Action

Number of setting 128(1 batch file processing and 10 write processing per group) Function Batch file execution, writing execution Batch file execution Argument can be specified, periodic, setting time execution

Writing process Periodic process from one second to 24 hours Heartbeat signal, increment value, decrement value, fixed value (numeric and tag value), time (year, month, day, hour, minute, second)

accessory function

Diagnostic display Group name, of the currently running, the number of items, the target / destination, monitoring period, the actual period, the number of alarm, start time which are currently running

Message display Icon, log number, date and time, type, output source, message content Excel startup function

Start up installed latest excell Corresponding to Microsoft Excel 2013/ 2010 / 2007 / 2003 / 2000

Other Wizard setting

assignment-suppression character

Dot (.), comma (,), at (@), dollar ($), pound (#), slash (/), percent (%), yen (¥), prime ('), double prime (“), semicolon (;), colon (:), question (?), exclamation (!), asterisk (*), plus (+), minus (-), pipeline (|), tilde (~), circumflex ( )̂, grave accent (`), ampersand (&), <> brackets, () brackets, {} brackets, [] brackets, space (␣)

*1 VT_ARRAY (array type) is not supported. *2 Handling when quality and error are not normal for IOPCDataCallback::OnDataChange event and

IOPCSyncIO::Read function

Page 20: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 20 -

4.2 Corresponding OPC DA interface Applicable OPC server in DxpLOGGER required following specifications. OPC server is required for OPC communication corresponding to interface below.

Type Interface Method

OPC Server object

IOPCCommon SetClientName

IOPCServer

AddGroup GetStatus SetStatus RemoveGroup

IOPCBrowseServerAddressSpace QueryOrganization ChangeBrowsePosition BrowseOPCItemIDs

IConnectionPointContainer FindConnectionPoint

OPC Group object

IOPCItemMgt AddItems RemoveItems

IOPCSyncIO Read

IOPCASyncIO2 Read Write

IConnectionPointContainer FindConnectionPoint

Client side interface IOPCDataCallback

OnDataChange OnReadFinish OnWriteFinish

IOPCShutdown ShutdownRequest

Page 21: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 21 -

5 Operation

5.1 Screen layout

5.1.1 The entire screen DxpLOGGER screen is constructed as follows.

5.1.2 Menu The menu of DxpLOGGER is as follows. 【file menu】

Item Content Create a new(N) Create a new project Open(O) Open a project Overwrite save(S) Overwrite and save a project file Save as(A) Save a project as a different name Import(I) Import a project information in CSV Export(E) Export a project information in CSV

Project opened recently(R) View project list opened recently(saved 5 recent projects) Able to open the project with clicking

Exite(X) Exite DxpLOGGER 【Setting menu】

Item Content Basic(E) View basic setting Communication (C) View communication setting String table(T) View string table setting Wizard(W) View wizard setting

Diagnostic

Log message view

Status bar

Setting window Explorer view

Tool bar Menu bar

Page 22: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 22 -

【Edit menu】

Item Content Create group(N) Create new group Logging setting(L) Create new logging setting Event setting(E) Create new event setting Alarm setting(A) Create new alarm setting Action setting(C) Create new action setting Edit group(I) Edit the selected group Delete group(D) Delete the selected group Delete(D) Delete the selected device, group and tag Select all(A) Delete all tag in the selected device Serch(F) Serch by specified tag name Array viewer (A) View array viewer Write of value (V) Write of present value in the tag Property(R) View selected property screen

【View menu】

Item Content Logging data list(L) View logging data list Alarm history(A) View alarm history list Trend graph(G) View graph Alarm summary(S) View alarm summary Explorer(X) View explorer view Log message(M) View message view Diagnosis(D) View diagnosis view View window side by side(W) View window in the setting window side by side Close all(C) Close all the window in the setting window

【Run menu】

Item Content Start all group(S) Start all setting group Stop all group(P) Stop all setting group Start selected group(G) Start the selected group Stop selected group(O) Stop the selected group

Disk write forcing(D) Write forcingat at the time of execution if write cache is carried out for running group.

【Tool menu】

Item Content Security setting(S) View security setting Log in(I) Log in from log out Log out(O) Log out from current user Start up Excel(X) Start up Excel (corresponding to Excel2010/2007/2003/2000)

【Help menu】

Item Content License(L) View license authentication screen Online help(O) View online help Version information(A) View version information

Page 23: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 23 -

5.1.3 Tool bar Tool bar and contents are as follows.

Icon function

Create a new project

Open a project

Overwrite and save a project file

View basic setting

View certificate setting

View communication setting

View setting wizard

(Drop down menu)

Create a new group

Edit the selected group

Delete the selected group

View windows in setting window side by side

Start all setting groups

Stop all setting groups

View alarm summary

View logging data list

View alarm history

View graph

View security setting

Log in from Log out

Log out from current user

Start up excel

Page 24: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 24 -

View version information

5.1.4 Explorer view In the explorer view, setting status in a project can be displayed and operate create new, edit and delete. View advanced setting of selected item in the setting window with left click(or enter key) View function which is related to selected item as pop up menu with right click or(shift key with enter key)

Explorer content Description Left click (Enter)

Right click (Shift with Enter)

Project setting Route ─ ─

Tag setting Tag list Tag setting for setting window ─

Logging setting Logging setting list ─ Add, start, stop

Group Logging group advance setting

View advance setting in the setting window

Change, delete, start, stop Up, down

Event setting Event setting list ─ Add, start, stop

Group Event group advance setting

View advance setting in the setting window

Change, delete, start, stop Up, down

Alarm setting Alarm setting list ─ Add, start, stop

Group Alarm group advance setting

View advance setting in the setting window

Change, delete, start, stop Up, down

Action setting Action setting list ─ Add, start, stop

Group Action group advance setting

View advance setting in the setting window

Change, delete, start, stop Up, down

Recipe setting Recipe setting list ─ Add, start, stop

Group Recipe group advance setting

View advance setting in the setting window

Change, delete, start, stop Up, down

Page 25: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 25 -

Point Displayed order in the explorer view can be changed with Up and Down. Running group order can not be changed.

5.1.5 Setting window 【Tag setting】 Setting window is displayed with left click of tag setting in the explorer. 【Logging format setting】 Setting window is displayed with left click of each group for logging setting of explorer and event setting.

Page 26: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 26 -

【Alarm item setting】 Setting window is displayed with left click of each group for alarm setting of explorer. 【Action setting】 Setting window is displayed with left click of each group for action setting of explorer. 【Alarm summary】 Current alarm can be displayed at the time of running alarm monitoring.

Page 27: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 27 -

5.1.6 Log message view Message is displayed in the log message view when the status is changed such as starting and stopping collection and error is occurred.

5.1.7 Diagnostic view Current running status is displayed in the diagnostic view.

5.1.8 Status bar Following information is displayed in the status bar. Item Content

Log in status Log in: user name is displayed Log out: Log out status is displayed

License status License status is displayed See more details to (3.4.4)

Page 28: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 28 -

5.2 Tutorial Set up in accordance with following procedure before using.

5.2.1 Install DxpLOGGER Insert install disk to CD drive in your PC and install DxpLOGGER. See more details to (3.1) about procedure of install.

5.2.2 Setting OPC server Set up OPC server for communication. Communication between device and OPC server has to be normal. See more details to manual of OPC server for setting OPC server.

5.2.3 Start up DxpLOGGER Start up DxpLOGGER from program menu. Following screen will be displayed.

Page 29: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 29 -

5.2.4 License activation of DxpLOGGER Lisence authentication is required before using DxpLOGGER. See more details to (3.4) about procedure of license authentication.

5.2.5 Basic setting of DxpLOGGER Proceed to basic setting of DxpLOGGER. Open basic setting in the setting menu.

Following basic setting screen will be displayed.

Confirm setting and revise setting if needed. Point ・ Check a box ‘ save output log to a file automatically’. Message information is output automatically to a file. It will

be useful when problems are occurred. ・’Years folder form(CSV only)’ is saved for each month. It is easy to control data.

Page 30: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 30 -

5.2.6 Start up preject wizard Set up logging setting or alarm setting in wizard setting. Open ‘wizard setting’ in the ‘setting menu’.

Following wizard setting screen will be displayed. Initial screen of wizard setting is displayed communication setting. Communication setting ‘OPC1’ is already selected. Press ‘Modify’ button.

Page 31: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 31 -

Following communication setting details screen will be displayed. Set up properly to match your distination OPC server. Press ‘OK’ button after setting and Finish communication setting.

Point ・Set up as follows if communicating with Takebishi DeviceXPlorer OPC server.

Server name:Takebishi.Dxp OPC delimiter character:Dot(.) Access path: Device name of OPC server or device name, group name Server process specified:Default

・Input installed machine node name to server node. Input null character or ‘local host’, if connecting OPC server in

the local machine. ・Set up as follows if communicating with Takebishi DeviceXPlorer OPC server via OPC UA. Endpoint: opc.tcp://[machinename]:52210/DeviceXPlorer5/UA Authority type: ANONYMOUSE ・Check the communication if setting is correct.

If there are more than one OPC server to connect(access path is not same), set up all communication.

Page 32: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 32 -

5.2.6.1 Communication setting

5.2.6.2 Tag setting Proceed to ‘Next’ in the wizard and tag setting is displayed. Select communication setting in the right OPC browse screen and press ‘browse’ button.

Access path is displayed after completing brows. Click the access path and register the tag. Tag is registered as follows. In addition to register to browse the OPC item, new tags are able to be registered.

OPC browse screen

1. Click access path

2. Drag item to register

3. Click [ << Add]

Page 33: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 33 -

5.2.6.3 Setting contents selection Proceed to ‘Next’ in the wizard and setting contents seclection screen is displayed.

【Periodic logging】

Select ‘logging setting’ and press ‘Next>>’(See (5.2.6.4)) 【PLC event (Trigger signal) logging】

Select ‘event setting’ and press ‘Next>>’(See (5.2.6.5)) 【Alarm monitoring】

Select ‘alarm monitoring’ and proceed to ‘Next>>’(See (5.2.6.6)) 【Excuting user program or processing periodic writing】

Select ‘action setting’ and proceed to ‘Next>>’(See (5.2.6.7))

Page 34: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 34 -

5.2.6.4 Periodic logging This section describes how to set up for logging at 10-second intervals. Select ‘logging setting’ in the wizard setting and proceed to ‘Next>>’. Logging group setting is displayed.

① Input any group name and table name (the added name of begging the file name). ② Input 10 seconds in logging period. ③ To log to CSV file, select CSV as logging distination and specify distination directory.

To log to ODBC database, select ODBC as logging distination and input DSN, user name and password. See more details to (6.5) about logging distination.

④ See more details to (6.6) about other setting sach as relative time log, trigger condition and file division. ⑤ Press ‘Next>>’ ⑥ Logging format setting is displayed.

Page 35: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 35 -

⑦ Select a tag from tag name list on the right and press ‘<<Add’.

⑧ Registered to format setting as follows.

⑨ Press [Finish].

⑩ Group name setting is displayed followed by logging setting.

Next see (5.2.7)

1. Drag tags for logging

2. Click ‘<<Add’

Page 36: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 36 -

5.2.6.5 Logging in accordance with the event Setting for logging each time when trigger signal is on from PLC is described as follows. Select ‘event setting>>’ in the wizard setting and proceed to ‘Next>>’. Event group setting is displayed.

① Input any group name and table name which are added to tbe beginning of the file name. ② Input 1 second for event monitoring period. ③ To log to CSV file, select CSV as logging distination and specify distination directory. To log to ODBC database,

select ODBC as logging distination and input DSN, user name and password. ④ Press [advanced setting ] ⑤ Set up PLC request tag and PC response tag. Set up logging tag from PLC and response tag from PC. Press

[OK] to finish setting. Ex. This is a setting when M0 is ON, data is logged and after completing logging, M1 is ON.

⑥ Press ‘Next>>’

Page 37: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 37 -

⑦ Loging format setting is displayed.

⑧ Select a tag from tag name list on the right and press ‘Register>>’.

⑨ Registered to format setting as follows.

⑩ Press [Finish]

1. Drag tags for logging

2. Click ‘<<Add’

Page 38: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 38 -

⑪ Group name setting is displayed followed by event setting.

Next see (5.2.7)

5.2.6.6 Alarm monitoring Setting for alarm monitoring of equipments and facilities.logging each time when trigger signal is on from PLC is described as follows. Select ‘event setting>>’ in the wizard setting and proceed to ‘Next>>’. Event group setting is displayed.

① Input any group name and table name which are added to tbe beginning of the file name. ② Input 1 second for event monitoring period. ③ To save alarm history to CSV file, select CSV as logging distination and specify distination directory. To save

alarm history to ODBC database, select ODBC as logging distination and input DSN, user name and password.

④ Press ‘Next>>’

Page 39: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 39 -

⑤ Alarm item setting is displayed.

⑥ Press [Register new alarm]. Set up alarm name, conditions, level and comment. Ex. This is a setting when ‘M0 is OFF,’ ‘D0 is 50 and M0 is ON’, ‘D1 is over 50 and D2 D3 value are not same’, alam is occurred.

⑦ Press [Finish] ⑧ Group name setting is displayed followed by Alarm setting.

Next see (5.2.7)

Page 40: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 40 -

5.2.6.7 User program execution and Periodic writing Setting for user program execution and periodic writing such as heartbeat signal is described as follows. Select ‘action setting>>’ in the wizard setting and proceed to ‘Next>>’. Action group setting is displayed

① Input any group name and table name. ② Specify trigger conditions if needed. ③ Press ‘Next>>’ ④ Action item setting is displayed. ⑤ Check in the “batch file execution” and set up a batch file setting to execute user program.

Ex. This is a setting to excute that parameter ‘test string’ is set in a executing file “C:¥Data¥Test.exe” at 10 o’clock every day.

Page 41: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 41 -

⑥ Check in the “Constant Action” and set up a Constant Action Setting to execute writing process such as

heartbeat signal.

Ex. This is a setting to write ‘heartbeat signal to M0 every second’ , ‘increment value(0-100) to D0 every 10 seconds’, ‘fix value 1234 to D1 every minute’, “Write Year(YYYY) to D2 every 10 minutes” Check in the “FTP Action” and set up a FTP Setting. Ex. This is a setting to Upload csv file to FTP Server from “C:¥Data¥LOGGER_Data” at 1 o’clock every day.

⑦ See more details to ”エラー! 参照元が見つかりません。“ about ”Batch Acrion”,”Constant Action”, “FTP Action ” ⑧ Press [ Finish ] ⑨ Group name setting is displayed followed by Action setting.

Page 42: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 42 -

5.2.7 Save setting file Setting is able to save as Project file. Select [Save] from menu of [File]. Select file path and fill out project name to saving.

5.2.8 Run Group Runs system. Select [Start All Group] from menu of [Run].

Page 43: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 43 -

While running, will have a “ (mark)“ at icon in Explorer view. System operating status is watcheble at Diagnostics view.

5.2.9 Logging Data View Logging Group or Event Group collecting data are displayed . Select [Logging Data View] from menu of [View].

Page 44: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 44 -

Collecting data are displayed as spread sheet by select Group name and date at Logging data view.

5.2.10 Viewing Histrical Trend Graph

Logging Group or Event Group collecting data are displayed as histrical graph. Select [Trend Graph] from menu of [View]. Collecting data are displayed as historical graph by select Group name and date at Graph window. Press [Load Graph from File].

Page 45: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 45 -

5.2.11 Viewing Realtime Trend graph

Logging Group or Event Group collecting data are displayed as trend graph. Select [Trend Graph] from menu of [View]. Select Group name and press [ReadTime Trend] at Graph View window. Setting update rate at Real Time Trend Setting window. Ex. For 60 seconds data is displayed by real time trend graph and update every one second.

Realtime trend graph is started after [Real Time Trend] press.

Page 46: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 46 -

5.2.12 Viewing currently Alarm

View currently alarm while being alarm monitored. Select [Alarm Summary] from menu of [View]. Alarm Summary is updated when alarm occured if “Auto Refresh” checked.

5.2.13 Viewing Alarm History

View collecting alarm history of Alarm monitoring. Select [Alarm History] from menu of [View].

Page 47: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 47 -

Alarms are displayed as spread sheet by select Group name and date at Alarm History view.

5.2.14 Stop Group

Stop to system. Select [Stop All Group] from menu of [Run].

Page 48: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 48 -

6 Troubleshooting

6.1 Error Messages Error messages showed in log view are listed below. 【All】 No Message Cause and countermeasures

1 Project file load error [***] occurs when the format of the project file is corrupted. 2 Specified file doesn't exist. Please make sure the path to the project file.

3 Stop all groups because DEMO mode finished. DEMO mode finished. Please activation license or restart application.

【Communication Setting】 No Message Cause and countermeasures

1 Failed to connect. Failed to connect OPC Server. Please check status OPCServer and communication setting.

2 Cannot discorvery endpoint. Cannot discorvery endpoint. Please check status OPCServer and communication setting.

3 Failed in AddGroup. Failed to connect OPC Server. Please check status OPCServer and communication setting.

4 AddItem failed. [OPC Item Name] Failed to add OPC item ***. Please check communication setting and Tag setting.

5 Cannot get data of Tag which failed in AddItem. This group is including tag which failed add item. Please check communication setting and Tag setting.

6 Re-connect with OPC Server because of three OPC action failure.

Re-connect with OPC Server because of three OPC action failure.

7 OPC starting timeout Please check status OPCServer and communication setting.

8 Receive OPC Shut down event. If DxpLOGGER gets shutdown event from connecting OPC Server.

【Logging Target(CSV or ODBC)】 No Message Cause and countermeasures

1 ODBC connection failed. DxpLOGGER failed to connect ODBC database. Please check ODBC setting.

2 Upload of offline buffering file failed. [***] Failed to connect save destination. Please check saving file (database).

3 Maximum number of off-line buffering count is exceeded, so old data was deleted.

Exceeded 30,000 as upper limit of the number of offline buffering. Please check saving file (database).

【Logging / Event】 No Message Cause and countermeasures

1 The logging is stopped because the logging setting has incorrect settings. Please check logging setting.

2 The event logging is stopped because the event logging setting has incorrect settings. Please check event setting.

3 Please specify Tag field. Please check logging format. 4 Please specify HandShake setting in Event setting. Handshake setting is required in the event setting. 5 Daily report output error. Failed output Daily Report.

Page 49: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 49 -

6 Yearly report output error. Failed output Yearly Report. 7 Specified reply tag doesn't exist. Please check handshake setting. 8 Specified request tag doesn't exist. Please check handshake setting. 9 Sync Read failed. Failed to read data in the handshake.

10 STRING_ERROR_HANDSHAKE_REP_OFF Handshake process does not work properly. 11 Setting reply tag for handshake to ON failed. Handshake process does not work properly. 12 Reading reply tag data for handshake failed. Handshake process does not work properly. 13 STRING_ERROR_HANDSHAKE_REQ_OFF Handshake process does not work properly. 14 Setting request tag for handshake to ON failed. Handshake process does not work properly. 15 Reading request tag data for handshake failed. Handshake process does not work properly. 16 Handshake is time-out. Handshake process timed out 30 second. 【Alarm】 No Message Cause and countermeasures

1 The Alarm monitor is stopped because the alarm setting has incorrect settings. Please check alarm setting.

2 Alarm Item doesn't exist. Please set alarm item setting. 3 Target Tag1 doesn't exist. [***] Alarm1 Tag 1 doesn't exist. 4 Target Tag2 doesn't exist. [***] Alarm2 Tag 2 doesn't exist. 5 Tag of value1 doesn't exist. Alarm1 Value1 Tag doesn't exist. 6 Tag of value2 doesn't exist. Alarm2 Value2 Tag doesn't exist. 【Action】 No Message Cause and countermeasures

1 The action process is stopped because the action setting has incorrect settings. Please check action setting.

2 Action items doesn't exist. Please set action setting. 3 Constant cycle action failed. [Tag Name]] Failed to cycle action. 4 Specified tag in constant action doesn't exist. Please check constant action setting. 5 Argument tag in batch file action doesn't exist. Please check argument tag in batch file action.

6 Batch file doesn't exist, so cannot run batch file. [***] Please make sure about batch file exist.

【Recipe】 No Message Cause and countermeasures

1 The recipe monitor is stopped because the recipe setting has incorrect settings. Please check recipe setting.

2 Recipe item doesn't exist. Please check recipe item setting. 3 Recipe No tag doesn't exist. Please check recipe No tag setting.

4 Specify recipe tag. Please set recipe tag. If this error is occurred in recipe item setting, please make sure about space exist.

5 Recipe triger tag doesn't exist. Please check recipe triger tag. 6 Invalid recipe no is specified. Please check value of recipe tag in recipe setting.

Page 50: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

- 50 -

7 Appendix

7.1 Copyright Information The copyright information on the third party software currently used by DxpLOGGER is shown. ComponentOne Studio Copyright (C) 2004 GrapeCity inc.

7.2 User Support TAKEBISHI offers a user support service to customers who have completed user registration. If you have any questions about how to set up or operate DeviceXPlorer, please contact the support service detailed below. When you contact the support service, you will be asked to confirm the following information, so please have it ready.

(1) Product name, serial number (written on the CD, license certificate and user registration card) (2) PC model, OS/service packs (3) PLC CPU type, communication unit model (4) Client software version/service pack/development language

Note The support service may not be able to answer questions that do not relate to DeviceXPlorer, such as how to set up the hardware and device driver or how to program the sequence programs and sample programs.

User Support TEL 075-325-2261/FAX 075-325-2273 [email protected] Open: 9:00 - 12:00 / 13:00 - 17:00

Page 51: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

F 13230D-A005 Nov 2018

DeviceXPlorer Data Logger User’s Guide

Page 52: DeviceXPlorer Data Logger ユーザーズガイド- Use of OPC (Supported OPCUA,OPCDA2.05 ) OPC is standard interface specification for communication, so you can access to the data

Instalaciones en Getaria

Larraioz Etxea, Eizaga Auzoa, Garate Mendi E-20808

GETARIA (Gipuzkoa), Spain

Instalaciones América Latina

Carlos Calvo 2480, B8000XAVBuenos Aires (Buenos Aires),

Argentina

Dirección postal

Larraioz Electrónica Industrial, S.L. Apartado de Correos 193 E-20800 ZARAUTZ

(Gipuzkoa), Spain

Instalaciones centrales

Francisco Aristeguieta Centro Tecnológico (F.A.C.T.)GI-3162 (Zarautz – Urdaneta) km 2,2

E-20809 AIA (Gipuzkoa), Spain

Tel. (+34) 943 140 139Fax. (+34) 943 140 327

E-mail. [email protected]

www.larraioz.com

SERVICIO TÉCNICO, CONSULTORÍA, TRAINING Y CANAL DE VENTA OFICIAL

Industry 4.0 VisionIndustrial AutomationMechatronics & Robotics