Technical Catalogue
DFRA-E seriesDesiccant rotor air dehumidifiers
Electric reactivation
![Page 2: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/2.jpg)
DFRA-E Series Technical Catalogue
General description
FISAIR
PSYCHROMETRIC CHART
NORMAL TEMPERATURE
Units SI
SEA LEVEL
Barometric pressure: 101,325 KPa
0 5 10 15 20 25 30 35 40 45 50
DRY BULB TEMPERATURE - °C
0 10 20 30 40 50
60
70
80
90
100
110
120
EN
TH
AL
PY
- K
J P
ER
KIL
OG
RA
M O
F D
RY
AIR
10
20
30
40
50
60
70
80
90
100
ENTHALP
Y - KJ
PER KIL
OGRAM OF
DRY AIR
SATURATI
ON TEMPERATU
RE - °C
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
21.0
22.0
23.0
24.0
25.0
26.0
27.0
28.0
29.0
30.0
31.0
32.0
33.0
34.0
VA
PO
UR
PR
ES
SU
RE
- M
M O
F M
ER
CU
RY
-10
-5
0
5
10
15
20
25
30
DE
W P
OIN
T T
EM
PE
RA
TU
RE
- °
C
Chart by: HANDS DOWN SOFTWARE, www.handsdownso
1.00
0.95
0.90
0.85
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.350.300.250.20 SENSIBLE HEAT RATIO = Qs / Qt
2
4
6
8
10
12
14
16
18
20
22
24
26
28
15%
25%
2%
4%
6%
8% RELATIVE HUMIDITY
10% RELATIVE HUMIDITY
20%
30%
40%
50%
60%
70%
80%
90%
5
510
10
15
15
20
20
25
25
30 WET BULB TEMPERATURE - °C
30
0.78
0.80
0.82
0.84
0.86 VO
LUM
E - C
UB
IC M
ETR
E P
ER
KG
OF D
RY A
IR0.88
0.90
0.92
HU
MID
ITY
CO
NT
EN
T -
GR
AM
S H
UM
IDIT
Y /
KG
DR
Y A
IR
Chart by: HANDS DOWN SOFTWARE, www.handsdownsoftware.com
The quality and efficiency requirements demanded by today’s society in terms of human comfort, and the control and stability of production processes, have made humidity control increasingly necessary or even essential.
The fact that the water vapour content of air varies greatly, and relative humidity depends on this, means it is vital to employ a dehumidification system for the reduction and control of this value whenever the water vapour content exceeds the humidity content permitted by the process.
That is why Fisair, which has been manufacturing since 1995, designs air dehumidifiers that enable the constant attainment of required humidity levels in a simple and precise manner, for minimal investment and operating costs.
Process Air
Dry Air
![Page 3: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/3.jpg)
Operating principles of desiccant rotors
DFRA series Fisair air dehumidifiers work using a high performance silica gel desiccant rotor, which is chemically and thermally stable, to prevent the deliquescence of the material it is made of, as occurs with other desiccant materials. Its cylindrical shape with a large number of small channels provides a large surface area for contact between the air and the desiccant material, which enables high levels of dehumidification, with a minimal volume of material.
Its simple method involves two air flows moving continuously and simultaneously as counter-currents across the desiccant rotor. The desiccant rotor is equipped with a rotation device and a series of perimeter seals to make the drying process continuous and uniform, and to optimize performance.
The flow of air for drying (process air), is filtered and passes through the desiccant rotor material (270º), and a proportion the water vapour molecules in the air are adsorbed. This air (dry air) is supplied to the controlled humidity zone by means of a fan.
The regeneration air flow from the desiccant rotor (reactivation air), is filtered and heated using an electric heater coil. It then passes through the desiccant rotor material (90º), and the water vapour molecules retained in the desiccant rotor are adsorbed, which regenerates the rotor for a new drying cycle. This air (wet air) is expelled outside of the controlled humidity zone, by means of a fan.
Fisair dehumidifiers have a long operating life because of the chemical resistance of the rotor and the possibility of washing it in water.
Standard dehumidifiers can ensure dry air humidity reaches dew point temperatures of up to -20ºC, or even lower on demand.
Wet air
Process air
Dry air
Reactivation air
Reactivation
(90º)
Drying(270º)
![Page 4: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/4.jpg)
DFRA-E Series Technical Catalogue
Data chart and general dimensions
Percentage variation table
(*) Process and reactivation air input conditions 20ºC/60% R.H.To calculate the drying capacity in other conditions, consult the percentage variation table.
(*) Approximate data used for quick capacity estimates; to be confirmed in each case.
DFRA-E models
Process/Dry Air
Dry Air Available Pressure
Reactivation/Wet Air
Wet Air Available Pressure
BR Electrical Power
(Reactivation Coil)
BR Electrical Power
(Reactivation Coil) with Heat Recovery
Total Electrical
Power
Total Electrical Power
with Heat Recovery
x (*) [Specific Capacity]
t (*) [Dry/Process Air]
Drying Capacity
(*)
Dimensions (mm)
Weight
(m3/h) (Pa) (m3/h) (Pa) (kW) (kW) (kW) (kW) (g/kg) (ºC) (kg/h) Length (A) Width (B) Height (C ) (kg)
DFRA-0065-E 450 300 135 200 4,5 3,7 5,6 4,8 5,5 18,5 3 1560 680 945 152
DFRA-0100-E 700 150 210 100 6,8 4,1 8,1 5,4 4,8 17 4 1623 685 945 164
DFRA-0130-E 900 550 270 250 9 7,2 10 8,2 5,7 19,5 6,1 1635 780 1025 175
DFRA-0160-E 1100 450 330 125 11,3 9,2 12,3 10,2 5,9 22,5 7,8 1635 780 1025 185
DFRA-0175-E 1200 400 360 300 13,5 11,1 14,8 12,4 6,3 23,5 9,1 1675 780 1025 185
DFRA-0200-E 1400 600 420 250 15,8 13,1 17,5 14,8 6,2 22,5 10,4 1650 800 1025 190
DFRA-0230-E 1600 500 480 350 18 15,1 19,9 17 6,1 22 11,7 1715 820 1025 200
DFRA-0300-E 2100 750 630 600 22,5 19,1 25,8 22,4 5,7 20 14,3 1785 875 1025 230
DFRA-0400-E 2700 700 810 400 27 22,1 30,8 25,9 5,8 21 18,8 1839 980 1265 352
DFRA-0500-E 3600 200 1080 550 36 30,6 39,3 33,9 5,7 19,5 24,6 1875 1070 1265 385
DFRA-0650-E 4500 450 1350 500 45 36,9 49,2 41,1 5,5 18 29,7 2020 1305 1525 520
DFRA-0900-E 6000 600 1800 650 63 53,6 70,8 61,4 5,7 20 41 2160 1425 1525 565
DFRA-1100-E 7500 450 2250 800 81 66,4 90,8 76,2 5,8 19 52,2 2204 1600 1865 725
DFRA-1300-E 9000 300 2700 650 99 84,2 109,6 94,8 6 21 64,8 2336 1575 1865 760
DFRA-1700-E 12000 1000 3600 350 126 103,3 144,1 121,4 5,9 22 85 2725 1950 1980 1025
DFRA-2100-E 15000 900 4500 250 162 137,7 181,1 156,8 5,9 21 106,2 2748 2095 1980 1175
DFRA-2900-E 20000 750 6000 350 200 164 215,1 179,1 5,7 21 136,8 3072 2400 2525 1870
DFRA-3500-E 24000 250 7200 200 240 204 258,6 222,6 5,6 20 161,2 3110 2400 2525 1970
Correction Coefficient Percentage (%) to be applied
to the drying capacity (*)
Process/Reactivation Air Temperature (ºC)
5 10 15 20 25 30 35
Relative Humidity of the
Process and Reactivation Air
(% R.H.)
40 25 38 57 73 90 105 110
50 35 46 70 87 105 120 125
60 40 60 78 100 120 125 135
70 50 68 90 110 130 135 145
80 56 75 95 120 135 140 -
95 62 80 105 130 140 145 -
Practical example: Starting with a DFRA-0300-E with 14.3 kg/h (at 20ºC and 60% R.H.), we want to know the capacity if the air being handled is at 30ºC and 70% R.H. The table shows us that a Correction Coefficient of 135% must be applied,
which gives a new capacity of 14.3-1.35= 19.31 kg/h (at 30ºC and 70% R.H.).
![Page 5: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/5.jpg)
Low performance nominal installed electrical power of the reactivation coil. Standard electrical connection 400V/III/50Hz and handling voltage 24Vca (others on demand). Technical data subject to change without prior notification.
DFRA-E models
Process/Dry Air
Dry Air Available Pressure
Reactivation/Wet Air
Wet Air Available Pressure
BR Electrical Power
(Reactivation Coil)
BR Electrical Power
(Reactivation Coil) with Heat Recovery
Total Electrical
Power
Total Electrical Power
with Heat Recovery
x (*) [Specific Capacity]
t (*) [Dry/Process Air]
Drying Capacity
(*)
Dimensions (mm)
Weight
(m3/h) (Pa) (m3/h) (Pa) (kW) (kW) (kW) (kW) (g/kg) (ºC) (kg/h) Length (A) Width (B) Height (C ) (kg)
DFRA-0065-E 450 300 135 200 4,5 3,7 5,6 4,8 5,5 18,5 3 1560 680 945 152
DFRA-0100-E 700 150 210 100 6,8 4,1 8,1 5,4 4,8 17 4 1623 685 945 164
DFRA-0130-E 900 550 270 250 9 7,2 10 8,2 5,7 19,5 6,1 1635 780 1025 175
DFRA-0160-E 1100 450 330 125 11,3 9,2 12,3 10,2 5,9 22,5 7,8 1635 780 1025 185
DFRA-0175-E 1200 400 360 300 13,5 11,1 14,8 12,4 6,3 23,5 9,1 1675 780 1025 185
DFRA-0200-E 1400 600 420 250 15,8 13,1 17,5 14,8 6,2 22,5 10,4 1650 800 1025 190
DFRA-0230-E 1600 500 480 350 18 15,1 19,9 17 6,1 22 11,7 1715 820 1025 200
DFRA-0300-E 2100 750 630 600 22,5 19,1 25,8 22,4 5,7 20 14,3 1785 875 1025 230
DFRA-0400-E 2700 700 810 400 27 22,1 30,8 25,9 5,8 21 18,8 1839 980 1265 352
DFRA-0500-E 3600 200 1080 550 36 30,6 39,3 33,9 5,7 19,5 24,6 1875 1070 1265 385
DFRA-0650-E 4500 450 1350 500 45 36,9 49,2 41,1 5,5 18 29,7 2020 1305 1525 520
DFRA-0900-E 6000 600 1800 650 63 53,6 70,8 61,4 5,7 20 41 2160 1425 1525 565
DFRA-1100-E 7500 450 2250 800 81 66,4 90,8 76,2 5,8 19 52,2 2204 1600 1865 725
DFRA-1300-E 9000 300 2700 650 99 84,2 109,6 94,8 6 21 64,8 2336 1575 1865 760
DFRA-1700-E 12000 1000 3600 350 126 103,3 144,1 121,4 5,9 22 85 2725 1950 1980 1025
DFRA-2100-E 15000 900 4500 250 162 137,7 181,1 156,8 5,9 21 106,2 2748 2095 1980 1175
DFRA-2900-E 20000 750 6000 350 200 164 215,1 179,1 5,7 21 136,8 3072 2400 2525 1870
DFRA-3500-E 24000 250 7200 200 240 204 258,6 222,6 5,6 20 161,2 3110 2400 2525 1970
A
B
C
![Page 6: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/6.jpg)
DFRA-E Series Technical Catalogue
Specifications – Mechanical Components
Standard mechanical components
(1) A self-supporting compact unit design made of galvanized steel with a phosphate coating and enamel finish in line with RAL 7035, with removable seals, covers and accesses to enable inspection and maintenance. (**) (Rock wool thermal insulation up to 50 mm thick and 1.5 mm of galvanized steel).
(RD) Desiccant rotor made of inert, fire-resistant, high performance silica gel material, which is thermally and chemically stable to prevent deliquescence.
(M1 y M2) Centrifugal air fans (M1 Process/dry air fan and M2 Reactivation/wet air fan) with a single ear and blades curved forwards, with a direct transmission engine, made from galvanized steel with a phosphate coating and enamel finish according to RAL 7035.
(M3) A rotation gear motor for the rotor with a pulley and V belt dragging system for the perimeter transmission with tensioner.
(FP y FR) G4 classification synthetic fibre V type air filters. (FP) Process air filter and (FP) Reactivation air filter.
(CP y CR) Process air intake flow manual regulation gates (CP) made of aluminium, and reactivation air (CR) made of galvanized steel with phosphate coating and enamel finish according to RAL 6018/6019.
(BR) Rotor reactivation air heater by means of electrical coils protected in stainless steel piping.
Optional mechanical components
(BF1 y BF2) Integrated pre-cooling coils (BF1) and/or post-cooling (BF2) for cold water, glycol water or gas. (**)
(BC1 y BC2) Integrated pre-heating coils (BC1) and/or post-heating (BC2) for coils, water or steam.
- Basic module made of stainless steel AISI-304.
- High pressure fans up to 15,000 Pa.
- Plug-Fans managed using a frequency variator.
- Turbine fans with reaction blades, made of stainless steel or transmission by belts/pulleys.
- Metal air filters with G3 classification,
- Synthetic fibre air filters with >G4 classification.
- Double electric / steam coil, or another thermal fluid, for reactivation air.
- Indirect evaporative cooler in the dry air.
- Heat recovery from the wet air to preheat the reactivation air.
- Wet air condenser for closed circuit operation.
- Motorized air gates.
Plug-Fan
HEPA filter
Heat recoverer
High pressure fan
![Page 7: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/7.jpg)
BC1(*)
Process air
Reactivation air
Wet air
Dry air
RD
BR
BF2(*)
BF1(*)
BC2(*)
Reactivation
(90º)
Drying(270º)
(*) Optional components
BF1and/or
BC1
M3 BF2and/or
BC2M1
M2
CP
BR
RD
FP
FR
CR
1
1
1
1
![Page 8: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/8.jpg)
DFRA-E Series Technical Catalogue
Specifications – Control and safety components
Standard control and safety components, DFRA-0065-E to DFRA-0175-E series.
(1) Electrical control panel with general isolator, circuit breaker switches, contacts and all the control gear necessary for a safety and handling device.
Handling voltage 24Vca.
(TF1) Automatic reset working thermostat.
(TS1) Manual reset safety thermostat.
(LED) Signalling LEDs (Voltage, On/Off and Fault).
Standard control and safety components, DFRA-0200-E to DFRA-3500-E series.
(1) Electrical control panel with general isolator, circuit breaker switches, contacts and all the control gear necessary for a safety and handling device.
Handling voltage 24Vca.
(LED) Signalling LEDs (Voltage, On/Off and Fault)
(PLR) PLR microprocessor, for the management and operational monitoring of the dehumidifier in real time, and the configuration of its controls and regulation.
(*) Equipment with PLR including the following components as standard:
(S1) Desiccant rotor rotation detector.
(SSR) Solid state relay for PID modulation of the heaters of the reactivation coil BR.
(P0) Differential pressure switch for safety in the reactivation/wet air flow.
(ST1) PT100 Temperature sensor placed in the reactivation air after the heaters.
(M4) Electrical control panel fan.
Optional control and safety components
(PLR) PLR microprocessor for the DFRA-0065-E to DFRA-0175-E series with all the standard components (*)
(P1 y P2) Differential pressure switches for the filters (process filter P1 and reactivation filter P2).
Remote signalling cards with three signals (voltage, on/off and fault) and nine signals (to be selected).
Humidistat, humidity sensors, temperature, dew point, actuators, valves, servomotors, etc.
![Page 9: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/9.jpg)
(ST2) Intake process air flow temperature sensor.
(SH1) Intake process air flow humidity sensor.
(ST3) Temperature sensor for the process air flow after BF1 and/or BC1.
(ST4) Temperature sensor for the dry air flow after BF2 and/or BC2.
(SH2) Humidity sensor for the dry air flow after BF2 and/or BC2.
(MV2) Actuator-valve for regulating the BC1 heating coil.
(MV3) Actuator-valve for regulating the BF1 cooling coil.
(MV4) Actuator-valve for regulating the BF2 cooling coil.
(MV5) Actuator-valve for regulating the BC2 heating coil.
MV2
MV3
ST3
S1
ST1
ST4and/or
SH2
P2
P0SSRM4
P1
ST2and/or
SH1
MV5
MV4
1PLR
LED
TF1TS1
BF1
BC1
BF2
BC2
![Page 10: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/10.jpg)
DFRA-E Series Technical Catalogue
MEASUREMENT AND SUPERVISION (SUP)
• Reactivationairtemperaturemeasuredafterthereactivation coil BR.
• On-screendiagramof theworkingof thecomponents(motor-fans and gear motor).
• Supervisionof thepowersuppliedbythereactivation coil BR.
• Supervisionof themeasurementof thehumiditysensor.
• Supervisionof thesetpointforhumidityandtemperature.
• Supervisionof thesetpointforthemaximumhumidityalarm.
CONFIGURATIONS FOR DIFFERENT OPERATIONS (CONF)
3ª) MEASUREMENT SIGNAL (M)
In order to act as a regulator/controller of the reactivation coil BR and possible pre or post cooling/heating coils (on demand), by means of 0… 10Vcc analogical signals from the humidity and temperature sensors.
1ª) STAGES (S)
In order to control the reactivation coil BR by means of one/two external digital signal/s on/off (in two stages).
2ª) PROPORTIONAL (P)
In order to control the reactivation coil BR by means of an external analogical signal 0… 10Vcc, from a regulator/humidity controller.
Functions provided by the PLR microprocessor
• Rotorrotation.
• Minimumflowof thereactivationair.
• Supervisionof thetemperatureof theSSR.
• Processairtemperaturemeasuredafterthepreorpost(cooling or heating) coil (on demand).
• Supervisionof theproportionalopeningof thevalve of the pre or post (cooling or heating) coil (on demand).
• Pressureswitchesinfilters(on demand).
S P M
CONF
ADJSUPINF
OK
DEL ALT
*ESC
H3H2
S PPM A
S PPM
SPM
HR%
ºC XgKgM
136ºC
Hr= 79%
28%P
Y=H
29%
107ºC
18.5ºC
107ºC
T=25ºC
![Page 11: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/11.jpg)
78ºC
18
ADJUSTMENTS (ADJ)
1) Adjusting the power supplied by each stage when configuration by stages is selected (S).
2) Adjusting the humidity setpoint when configuration by measurement signal is selected (M).
3) Adjusting the maximum deviation of the humidity alarm when configuration by measurement signal is selected (M).
4) Adjusting the setpoint of the temperature of the range of pre/post cooling coils (BF1 and/or BF2) or pre/post heating coils (BC1 and/or BC2) (on demand).
SECURITY AND ALARMS
• Timingof thedisconnectionof themotor-fanof thewetairandthedragging gear motor for cooling the equipment.
• Stoppageof theBRheaterbecauseof excessivetemperatureinthereactivation.
• Alarmandstoppageof theunitbecauseof alackof airinreactivation.
• Alarmandstoppageof theunitbecauseof alackof rotation in the desiccant rotor.
• Alarmandstoppageof theunitbecauseanyof thethermalswitches of the motors are set off.
• Alarmandstoppageof theunitbecauseanyof theelectricalprotections of the heaters are set off.
• Alarmandstoppageof theBRheaterbecausethemaximumtemperature of the SSR is continuously exceeded.
• Alarmbecauseprocessandreactivationfiltersareblocked(ondemand).
• Alarmbecausethemaximumdeviationforthehumiditysetpointisexceeded.
• Alarmandstoppageof theheaterbecauseof anelectro-mechanicalfault in the contacts of the BR or excess temperature in reactivation.
78ºC
18
Space for the alphanumeric indicator
for displaying unit faults.
1 2 3 4
HE= 35%HR= 29%
36%
T ºC 19 ºC
![Page 12: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/12.jpg)
DFRA-E Series Technical Catalogue
Closed system
3
3
3
3
3
2
2
2
2
4
4
4
4
4
1
1
1
1
1
3
4
Recirculated air 100%
Exterior air 100%Open system
1E
1E
1R
1R
Mixture exterior / recirculated air
Mixed system
ø
Types of installation
I
I
I
E
E
E
ø
ø
ø
ø
ø
ø
ø
ø
![Page 13: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/13.jpg)
Leyenda: Wet air
Regulation gate
Interior installation
Exterior installation
Extractor
Air-handling unit
3
3
3
2
2
2
4
4
1
1
1
4
1E I
E1R
Mixture exterior / recirculated air
AHU
AHU
Mixture exterior / recirculated air
Mixed systemDehumidifier in air-handling unit
return by-pass
Mixed systemDehumidifier in air-handling unit
exterior air intake
Dehumidifier
Process air
Exterior process air
Return process ai
Dry air
Reactivation air
øø
ø
ø
ø
ø
ø
E
E
![Page 14: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/14.jpg)
DFRA-E Series Technical Catalogue
Typical applications
MANUFACTURING PROCESSESPharmaceutical industry, polymer plastics, textiles, chemicals…
PRODUCT DRYINGCured meats, cheeses, sweets, chocolate, powdered foods, photographic paper…
![Page 15: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/15.jpg)
COLD WAREHOUSES AND CHAMBERS
Slippery floors, defrosting, electrical faults, high consumption levels…
PREVENTING CORROSIONAutomotive industry, shipbuilding, electricity plants, weaponry, electronic materials…
CONSERVATIONDry warehouses, paper and wood, covered swimming pools, works of art, granular materials…
![Page 16: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/16.jpg)
DFRA-E Series Technical Catalogue
Graphs of capacities (*)
Technical data subject to change without prior notification
DFRA-0065-E
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0100-E
Xe/Xs Xe/Ts
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0130-E
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0160-E
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
![Page 17: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/17.jpg)
Fixed parameters:
- Process/Reactivation Air Temperature: 20 ºC
- T Coil according to Nominal Power
- Absolute Humidity of the Reactivation Air same as Process Air
Eg: Process air
Input data:
•20ºC•Absolutehumidity9g/kg
Table data:
•Dryairtemp=44ºC
•Absolutehumidity=2,8g/kg
(*) For other operating conditions, request the corresponding capacity
DFRA-0200-E
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0230-EA
bso
lute
Hum
idity
of
Dry
Air
(Xs)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0300-E
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0400-E
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0175-EA
bso
lute
Hum
idity
of
Dry
Air
(Xs)
Dry A
ir Temp
erature (Ts)
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
Absolute Humidity of Process Air (Xe)
3032
34
36
38
40
42
44
48
46
50
g/kg
![Page 18: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/18.jpg)
DFRA-E Series Technical Catalogue
DFRA-0650-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0900-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-1100-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-0500-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
Xe/Xs Xe/Ts
Graphs of capacities (*)
Technical data subject to change without prior notification
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
![Page 19: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/19.jpg)
DFRA-1300-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-1700-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-2100-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-2900-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
DFRA-3500-E
5 6 7 8 9 10 11 12 13 140
1
2
3
4
5
6
7
8
g/kg ºC
3032
34
36
38
40
42
44
48
46
50
g/kg
Fixed parameters:
- Process/Reactivation Air Temperature: 20 ºC
- T Coil according to Nominal Power
- Absolute Humidity of the Reactivation Air same as Process Air
(*) For other operating conditions, request the corresponding capacity
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
Ab
solu
te H
umid
ity o
f D
ry A
ir (X
s)
Dry A
ir Temp
erature (Ts)
Absolute Humidity of Process Air (Xe)
![Page 20: DFRA-E series - Accubel · DFRA-E series Desiccant rotor air ... FISAIR PSYCHROMETRIC CHART NORMAL TEMPERATURE Units SI SEA LEVEL Barometric pressure ... The table shows us …](https://reader030.vdocument.in/reader030/viewer/2022012917/5b5741847f8b9a8f128d7cc9/html5/thumbnails/20.jpg)
DFRA-E seriesTechnical Catalogue