dfx-mm series - cross technical services · dfx-mm is repeatable according to api mpms 5.8 table...

8
09/10/2012 Page1 L002H DFX-MM leaflet High-end Ultrasonic Flow Meters for Liquid Hydrocarbons Custody Transfer DFX-MM DFX-MM series series 32 beams for ultimate performance 32 beams for ultimate performance

Upload: doanliem

Post on 27-Jul-2018

235 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: DFX-MM series - Cross Technical Services · DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in ... DFX-MM series Ordering codes DFX-MM ordering contacts METERING

09/1

0/2

012 P

age1

L002H

DFX

-MM

lea

flet

High-end Ultrasonic Flow Meters

for Liquid Hydrocarbons Custody Transfer

DFX-MMDFX-MM seriesseries

32 beams for ultimate performance32 beams for ultimate performance

Page 2: DFX-MM series - Cross Technical Services · DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in ... DFX-MM series Ordering codes DFX-MM ordering contacts METERING

09/1

0/2

012 P

age2

L002H

DFX

-MM

lea

flet

Features & benefits

DFX-MMDFX-MM seriesseries

Applications

PerformanceA master meter class UFM exceeding current standards

from Naphtas / Condensates / Liquid gases to Heavy

crudes / Fuel oils

Superior linearity and repeatability thanks to unequalled

spatial coverage and ultra-fast scanning rate

Compliant with OIML R117-1 class 0.3, M.I.D.

2004/22/EC and API MPMS Ch5.8

Truly Provable with standard turbine prover loops

Design32-beams patented design

Transit time operating principle

Unique 22.5° axial symetry with excentration design for

really much less sensitivity to flow profile disturbances

Small volume transducers cavities minimize the scaling

effects and avoid gas pockets

InstallationReduced straight runs installation possible

Compact integrated electronics for easy site

commissioning and start-up

CommunicationHigh integration to common flow computers

Secure ethernet communication

HTML-based configuration and auditing software with

open communication protocol for on-line remote

technical support

Powerfull flow imaging capability

ServiceUltrasonic paths redundancy allows scheduled site

maintenance and downtime reduction.

Transducers exchangeable without recalibrating the

meter

FSO's & FPSO's custody transfer (Crude oil)

On and Offshore allocation metering (Crude

oil, condensates)

Pipeline metering stations (Crude Oil, Refined

products)

Tanker loading / offloading terminals (Crude

Oil, Refined products, Petrochemicals)

Storage management (Crude Oil, Refined

products, Petrochemicals)

Page 3: DFX-MM series - Cross Technical Services · DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in ... DFX-MM series Ordering codes DFX-MM ordering contacts METERING

DFX-MM requires much less prove volume than other UFM's and therefore is truly provable with standard turbine prover loops where other UFM's definitively should be proved by master meter method.

DFX-MM is provable with standard ball provers thanks to repeatability improved by its unequaled spatial coverage and ultra-fast scanning rate.

DFX-MM accurately measures viscous flows and therefore is ideal when pressure drop is the concern.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

-0,06%

-0,04%

-0,02%

0,00%

0,02%

0,04%

0,06%

DFXMM 08 - REPEATABILITY testDiesel oil 4.9 cs t - 600 m3/h - 10 m3 ball prover - 15 runs

RUN n°

ME

TE

R E

RR

OR

%

50 100 150 200 250 300

0,998

0,999

1,000

1,001

1,002

DFXMM 06 - HEAVY OIL

300 cent is t ockes mineral oil, 6'' PD mast er met er

FLOWRATE M3/H

ME

TE

R F

AC

TO

R

09/1

0/2

012 P

age3

L002H

DFX

-MM

lea

flet

DFX-MMDFX-MM seriesseries

Proving volumeComparison with other UFM's

Repeatability & Heavy Oil

1 10 1000

10

20

30Recommended Prover Volume v/s Meter Size

API MPMS chapter 5-8 recommendation

Conventional UFM #1

Conventional UFM #2

DFX-MM proving requirements

Prover Volume ( m3 )

Met

er S

ize

( in

ch )

DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in the difficult Reynolds flow transition area (medium to high viscosity oils) the difficult Reynolds flow transition area (medium to high viscosity oils)

Page 4: DFX-MM series - Cross Technical Services · DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in ... DFX-MM series Ordering codes DFX-MM ordering contacts METERING

09/1

0/2

012 P

age4

L002H

DFX

-MM

lea

flet

Calibration curves

DFX-MMDFX-MM seriesseries

DFX-MM sustains a premium +/- 0.10 % accuracy with a constant K-Factor DFX-MM sustains a premium +/- 0.10 % accuracy with a constant K-Factor over a wide range of viscosities and of operating conditions. over a wide range of viscosities and of operating conditions.

0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000

0.9900.9910.9920.9930.9940.9950.9960.9970.9980.9991.0001.0011.0021.0031.0041.0051.0061.0071.0081.0091.010

DFX-MM 08'' : baselinesDFX-MM 08'' : baselinesFlowstraightener 7 D long, ball prover volume 10m3

JET FUEL 5,0 cst 17 °C Water 6%

JET FUEL 4,5 cst 24 °C

JET FUEL 4,5 cst 24 °C Ball valve 40% closed

GASOIL 8,4 cst 18 °C

GASOIL 8,4 cst 18 °C Ball valve 40% closed

OIL 15,5 cst 22 °C

OIL 62,0 cst 16 °C

Same oil, no flow conditioner

Flowrate

Mete

r Fact

or

2,000 20,000 200,000 2,000,0000.9900.9910.9920.9930.9940.9950.9960.9970.9980.9991.0001.0011.0021.0031.0041.0051.0061.0071.0081.0091.010

DFX-MM 08'' : baselines v/s Reynolds NumberDFX-MM 08'' : baselines v/s Reynolds NumberFlowstraightener 7 D long, ball prover volume 10m3

JET FUEL 5,0 cst 17 °C Water 6%

JET FUEL 4,5 cst 24 °C

JET FUEL 4,5 cst 24 °C Ball valve 40% closed

GASOIL 8,4 cst 18 °C

GASOIL 8,4 cst 18 °C Ball valve 40% closed

OIL 15,5 cst 22 °C

OIL 62,0 cst 16 °C

Same oil, no flow conditioner

Reynolds Number

Mete

r Fact

or

Page 5: DFX-MM series - Cross Technical Services · DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in ... DFX-MM series Ordering codes DFX-MM ordering contacts METERING

Featuring in DFX-MM software suite :

CALIBRATION PERFORMANCE MONITORING

TRACEABILITY

DATA VISUALIZATION & PLOTTING

DATA LOGGING

DIAGNOSTICS

PROVING SUPPORT

DOCUMENTATION COMMUNICATION

09/1

0/2

012 P

age5

L002H

DFX

-MM

lea

flet

Calibration Performance Monitoring

DFX-MMDFX-MM seriesseries

DFX-MM is the only ultrasonic flow meter performing real time comparison between factory calibration & site operating conditions.

DFX-MM interfacing is easy and cost effective thanks to its Web server DFX-MM interfacing is easy and cost effective thanks to its Web server and Ethernet link, making skid commissioning, meter health check and and Ethernet link, making skid commissioning, meter health check and

auditing operations straightforward. auditing operations straightforward.

Page 6: DFX-MM series - Cross Technical Services · DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in ... DFX-MM series Ordering codes DFX-MM ordering contacts METERING

mm Min. Max. Min. Max.

04" * 100 15 350 100 2200

150 30 800 200 5000

200 60 1400 400 8800

250 90 2200 600 13800

300 130 3200 800 20100

350 160 3800 1000 23900

400 200 5000 1300 31400

450 250 6200 1600 39000

500 350 7800 2200 49100

600 500 11000 3100 69200

650 600 13000 3800 81800

700 700 16000 4400 100600

750 900 18000 5700 113200

800 1000 20000 6300 125800

850 1100 23000 6900 144700

900 1200 26000 7500 163500

950 1300 29000 8200 182400

1000 1400 32000 8800 201300

42" 1050 1500 36000 9400 226400

Nominal f low ranges

for s tandard accuracy +/-0, 15%

Meter s ize Flow rate (m3/h) Flow rate (BPH)

Inch

06"08"10"12"14"16"18"20"24"26"28"30"32"34"36"38"40"

* 15 beams design

mm Min. Max. Min. Max.

04" * 100 30 300 200 1900

150 65 650 400 4100

200 120 1200 800 7500

250 200 2000 1300 12600

300 300 3000 1900 18900

350 320 3200 2000 20100

400 400 4000 2500 25200

450 520 5200 3300 32700

500 650 6500 4100 40900

600 1000 10000 6300 62900

650 1150 11500 7200 72300

700 1350 13500 8500 84900

750 1550 15500 9700 97500

800 1750 17500 11000 110100

850 2000 20000 12600 125800

900 2200 22000 13800 138400

950 2500 25000 15700 157200

1000 2750 27500 17300 173000

42" 1050 3000 30000 18900 188700

Nominal f low ranges

for premium accuracy +/-0 , 1%

Meter s ize Flow rate (m3/h) Flow rate (BPH)

Inch

06"08"10"12"14"16"18"20"24"26"28"30"32"34"36"38"40"

* 15 beams design

type

# 150 # 300 # 600 #900 # 150 # 300 # 600 # 900

DFX-MM04 51 60 72 79 113 132 159 174

DFX-MM06 70 88 113 151 154 194 249 333

DFX-MM08 99 125 159 215 218 275 350 473

DFX-MM10 139 176 240 300 306 388 528 660

DFX-MM12 186 232 328 394 410 511 722 867

DFX-MM14 230 300 352 506 660 775

DFX-MM16 258 364 448 568 801 986

DFX-MM18 295 442 650 973

DFX-MM20 350 504 770 1101

DFX-MM24 495 721 1089 1587

DFX-MM26 568 866 1250 1906

DFX-MM28 646 1035 1422 2277

DFX-MM30 748 1192 1646 2623

DFX-MM32 862 1322 1897 2909

DFX-MM34 951 1553 2093 3417

DFX-MM36 1072 1742 2359 3833

DFX-MM38 1194 2627

DFX-MM40 1355 2981

DFX-MM42 1423 3130

Weight

Weight (kg) Weight ( lb)

09/1

0/2

012 P

age6

L002H

DFX

-MM

lea

flet

DFX-MM performance

DFX-MMDFX-MM seriesseries

Technical data

type

mm mm

DFX-MM04 4'' 100 16 406

DFX-MM06 6'' 150 18 457

DFX-MM08 8'' 200 20 508

DFX-MM10 10'' 250 22 559

DFX-MM12 12'' 300 24 610

DFX-MM14 14'' 350 28 711

DFX-MM16 16'' 400 32 813

DFX-MM18 18'' 450 36 914

DFX-MM20 20'' 500 40 1016

DFX-MM24 24'' 600 48 1220

DFX-MM26 26'' 650 52 1321

DFX-MM28 28'' 700 56 1422

DFX-MM30 30'' 750 60 1524

DFX-MM32 32'' 800 64 1626

DFX-MM34 34'' 850 68 1727

DFX-MM36 36'' 900 72 1829

DFX-MM38 38'' 950 76 1930

DFX-MM40 40'' 1000 80 2032

DFX-MM42 42'' 1050 84 2130

Length*

Meter s ize Meter length

Inch Inch

Note : given length are for face to face flanges

Page 7: DFX-MM series - Cross Technical Services · DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in ... DFX-MM series Ordering codes DFX-MM ordering contacts METERING

METROLOGY:

API MPMS ch5.8M.I.D. 2004/22/EC

:

::

Installation :

CERTIFICATIONS

:pressure : P.E.D. 97/23/EC

ASME B31.3: OIML R117-1 (PTB-1.5-4037579)

GOST-M (FR.C.29.006.A N°38166)SIRIM ATS 04/10

MIGAS (14599/18.06/DMT/2009)SPRING WMO 423/08

INMETRO (P-0003-11-36896-10)

: E.M.C 89/336/EC: I.P. 66/67 IEC529

ENVIRONMENT:

Pressure ::

:

BODY:

: ANSI #150 #300 #600

: full bore

CONVERTER: 110 / 220 VAC 50/60 Hz or 18 / 32 VDC, 10W, isolation 1500V

Pulse volume output :Communication port :

Compliances OIML R117-1 class 0.3

Accuracy +/- 0.15% from 0.5 to 12 m/s+/- 0.10% from 1 to 10 m/s

Repeatability provable, 0.05% 5 runs with conventional prover loopsUncertainty +/-0.027% at 95% confidence level as per API MPMS 5.8 table B-1

10D upstream with recommended flow conditioner + 3D downstream

compliant with all relevant European Community standardsSafety ATEX 94/9/EC II 2 G Exd IIB T6

Metrology

EnvironmentIngress protection

Temperature process : -55°C to + 120°CAmbient: -55°C to + 55°C

Up to 100 barViscosity 0.1 to 600 centistockes

please consult M&T for higher viscosities

Density 400 to 1500 kg/m3

Materials Carbon steel, Low temp carbon steel, Stainless steel, Duplex

Flanges

Internal

Power supplytwo static relays 350V 0.12A isolation 5000V 10/100Base-T IEEE 802.3 Ethernet link RJ45,

optional Wifi 802.11 b & g, optical fiber, RS485

Please contact M&T for specifications outside above standard ones

09/1

0/2

012 P

age7

L002H

DFX

-MM

lea

flet

Specifications

DFX-MMDFX-MM seriesseries

Page 8: DFX-MM series - Cross Technical Services · DFX-MM is repeatable according to API MPMS 5.8 Table B-1 including in ... DFX-MM series Ordering codes DFX-MM ordering contacts METERING

A B - C D - E F - G H

DFX-MM 12 - A 1 - 1 1 - 1 0

09/1

0/2

012 P

age8

L002H

DFX

-MM

lea

flet

DFX-MMDFX-MM seriesseries

Ordering codes

DFX-MM ordering contacts METERING & TECHNOLOGY S.A.S.

Address : Parc des Propylées II - 5, Allée Prométhée 28000 CHARTRES FRANCE

Tel: +33 (0) 965 027 803 / 237 835 446Fax: +33 (0) 237 835 547E.mail : [email protected] : www.mnt-sas.com

Section A : Product line

DFX-MM

Section B : Meter Size

04 4'' / DN100

06 6'' / DN150

08 8'' / DN200

10 10'' / DN250

12 12'' / DN300

14 14'' / DN350

16 16'' / DN400

18 18'' / DN450

20 20'' / DN500

24 24'' / DN600

Section C : Pressure Class

A 150# ANSI R.F. Flanges

B 300# ANSI R.F. Flanges

C 600# ANSI R.F. Flanges

D Other (please contact us)

Section D : Materials of construct ion

Body Flanges Transducers

1 C.S A106 or equ. C.S A105 or equ. Peek / SS 316L

2 L.T.C.S. A333 Gr6or equ.

L.T.C.S. A350 LF2 orequ.

Peek / SS 316L

3 SS 316L or equ. SS 316L or equ. Peek / SS 316L

4 Other Other Peek / SS 316L

Section E : Installat ion condit ions

1 Standard with recommended flow straightener

2 Standard without flow straightener

3 Customized

Sect ion F : Accuracy class

1 standard +/-0.15%

2 premium +/-0.1%

Section G : Documentat ion

0 None

1 Standard

2 Customized

Section H : Special request

0 None

S Special request