dgpec022912a
DESCRIPTION
Diseño RefuerzoTRANSCRIPT
![Page 1: DGPEC022912a](https://reader036.vdocument.in/reader036/viewer/2022081908/55cf8e10550346703b8e21c4/html5/thumbnails/1.jpg)
6430 S. 39th W. Ave. Tulsa, OK 74132Ph: 918-584-2220 Fax: 918-584-2221
Wrap calculations have taken into consideration all information provided on the Engineering Assessment and are subject to Citadel Technologies' Terms and Conditions.The following calculations apply only to Citadel Technologies' products.
Case #: DGPEC022912a1097.39m; 5.59h
Diamond Wrap® Contact Owner Contact
= User Input = Material Properties
Desired Pressure = 380 psi
Operating Temp. = 201 °FMaterial Used: CB
Temp. Derating Factor: ƒT = 0.6
Service Factor: ƒ = 0.333Number of
Plies = 4
Poisson's Ratio: ν = 0.196
Modulus: Eac = 4,223,486 psi
Epoxy type: High Temp. Amb.
Repair Thickness: tmin = 0.09 in OD of Pipe, D = 16.000 in
Diameter of Defect, d = 0.25 in Nominal Pipe Wall , t = 0.375 in
Shear Modulus: G = 88,780 psiComposite Modulus in Axial
Direction Ea = 3,051,498 psi
Toughness Parameter, γ = 2.5 in.-lb/in2 Lap Shear Strength, τ = 1,000 psiAllowable Axial Strain in Composite εa = 0.01297
ASME PCC2 Equation (13):
P= 504.6 psi
Equation (17): 4.9003
Lover = 4.90 in 3.5624
Is # of Plies Acceptable? Yes
This repair requires 4 plies of material and should extend a minimum of4.90 inches from the defect on all sides.
Repair Recommendations:
(1) DW-HP-XM-1604HTA (16 inch DiamondWrap® HP™ 4-ply High Temperature Ambient 1 meter wide kit)
Project? (Yes/No) Reviewed by: Date:
City, Zip, CountryEmail
PhoneFax
593-3-2380 658
Enter number of plies until pressure rating is satisfied.
Note: The leak must be stopped prior to the installation of this repair kit. A warranty cannot be offered for components suffering from internal corrosion. Citadel Technologies' products are not designed to stop crack propogation. Proper surface preparation is required to ensure adequate bond strength to the substrate.
PEC CIA LTD. Joel Gualberto Bernal Clavijo/Engineer
Manuel Maria Hidalgo S/N yvia interoceánica KM 26
Quito Ecuador
Installation Instructions: Wrap with 100% overlap for complete 4-ply repair. This kit will provide 1 meter of repair length and hold up to a .25 inch diameter through-wall defect no closer than 5 inches from the edge of the repair.
CompanyName
Address
REPSOLDAVID BALDEON
Enter cloth types: AA, BA, CA, CB, or HY
Lover =max 2.5 Dt / 2,Ea!atrepair
"
!
"#
$
%& 2.5 Dt / 2 =
Ea!atrepair"
=
P = fT f!LCL
1!" 2( )Eac
3512tmin
3 d 4 + 1!d
"
#$
%
&'+
364Gtmin