diagnostics for intense e-cooled ion beams by vsevolod kamerdzhiev forschungszentrum jülich, ikp,...

35
Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

Upload: theodore-cross

Post on 04-Jan-2016

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

Diagnostics for intense e-cooled ion

beamsby Vsevolod Kamerdzhiev

Forschungszentrum Jülich, IKP, COSY

ICFA-HB2004, Bensheim, October 19, 2004

Page 2: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 2

Content

• Objects of diagnostics

• What is an electron-cooled ion beam from

the diagnostics point of view?

• Parameters to be measured and

corresponding diagnostic methods.

• Diagnostics for electron-cooled beams,

difficulties and advantages.

Page 3: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 3

Objects of diagnostics

• Electron beam– High beam power– Beam pipe is inside the solenoid

• Electron-cooled ion beam– Intensities differ in orders of magnitude– High beam density– Small transverse dimensions– Small momentum spread

Page 4: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 4

• E-beam position• Space charge field

of the e-beam• Current• Temperature• Neutralization

Measured parameters (e-beam)

Page 5: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 5

Measured parameters (ions)

• Beam current • Position along the orbit• Momentum• Momentum spread• Profile• Emittance• Tune• BTF

Page 6: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 6

Interceptive methods or not?

• Interceptive methods– Not suitable for a circulating beam (operation)– Any probe will melt when inserted in the dc

electron beam

• Not interceptive methods– Often indirect measurements– Suitable for (high current) rings

Page 7: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 7

Cooler Synchrotron COSY

- COSY accelerates (polarized) protons and deuterons between 300 and 3700 MeV/c for p 535 to 3700 MeV/c for d

- Kicker extraction, stochastic extraction

- 4 internal and 3 external experimental areas

- Electron cooling at low energy

- Stochastic cooling at high energies

Page 8: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 8

COSY-Cooler

Page 9: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 9

COSY-Cooler

Electron energy:Up to 100 kV

Electron current: 0.2 - 3 A

Operating at: 24,5kV

100-250 mA

Page 10: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 10

e+ trap

Septum

Cooling section

Quadrupole

Collectore-gun

BDetector

e+ source

LEPTA

Page 11: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 11

LEPTA

Electron gun

Page 12: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 12

Parameters of e-cooled ion beam

• Small transverse size/emittance

• High density• Small momentum

spread• During e-cooling

the ion beam is dc• Often unstable

Longitudinal Schottky spectra, uncooled and cooled proton beam

Page 13: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 13

• Pick-ups (at least two) are needed inside the cooling section to measure the position of both beams.– To measure the position of the e-beam

longitudinal modulation must be applied– Large dynamic range of preamplifiers (variable

gain)– Difficulties in mechanical design, bad service

possibilities (COSY, LEPTA…)

Diagnostics in the cooler section

Page 14: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 14

COSY BPMs

Page 15: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 15

• Count rate of the particles recombinating in the

cooler section can be used to find optimum alignment of the electron and ion beams and for fine tuning the energy of the electron beam.

• Measurement of the profile of recombination particles (e.g. MWPC) is the easiest way to determine the ion beam profile (only during cooling process)

Diagnostics in the cooler section

Page 16: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 16

Example of H0-profile measurement at COSY

Calculated from the measured H0- Profiles

Em

itta

nce

[m

rad

]B

eam

radiu

s [m

m]

horizontalvertical

Proton beam current

Page 17: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 17

• Looking at the signals of the pick-up located in the cooling section in frequency domain gives useful information about residual gas ions oscillating in the cooler section.

• Such a pick-up can be used also as a clearing electrode (experience at COSY, I.Meshkov, A.Sidorin). Applying ac-voltage to the clearing electrodes makes it possible to kick out the trapped ions, provided the frequency corresponds to resonant the frequency of a particular ion species.

Diagnostics in the cooler section

Page 18: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 18

Space charge field

To measure the space charge parabola of the electron beam a low intensity cold ion beam can be used.

In this case the ion beam is used as a probe which scans the e-beam.

Procedure:Inject ion beam in the machine, cool it, measure the

revolution frequency of the ion beam, make a parallel shift of the e-beam using the cooler magnetic system, measure the frev again, repeat the procedure several times shifting the e-beam in both directions from the initial position.

Page 19: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 19

Temperature of the e-beam

Longitudinal temperature can be derived from the Schottky spectrum of the cooled ion beam Beam heating effects should be taken into account

Transverse temperature can be measured by the pepper pot method Only in the pulsed mode Requires complex mechanical design

Page 20: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 20

The idea of T-measurement

The optical analysis of the electron beam temperature, V. Golubev et all., Proceedings of the Workshop on Beam Cooling and Related Topics, 1993.

The electrons move in the longitudinal magnetic field.

Method based on the measurement of transverse Larmor radius

Pulse duration – 20-50 s

Page 21: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 21

Profile of the ion beam

Can be based on:

• Ionization of residual gas • Laser induced luminescence• Laser induced photo-neutralization• Light radiation of residual gas,

exited by the beam particles • Wire scanner

Page 22: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 22

Ionization profile monitor

е-

H+

Proton beam

+

Y

X

Detector for ions

Detector for electrons (optional)

If collecting the electrons additional magnetic field is required.

Position sensitive detectors are usually based on the MCPs.

For dense beams MCP life time is a crucial issue.

IPMs are installed in:TSR, SPS, COSY,RHIC…

Page 23: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 23

IPM at COSYIon

Electrons

MCP in Chevron Geometry

Charge signalAnode

Channels

MCP1

MCP2

Page 24: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 24

Beam Profiles measured in COSY

Electron cooled proton beam

Profile measurement

The proton beam is not cooled

1,3·109 particles in the ring, 45 MeV.

Page 25: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 25

Experience with IPM at COSY

• For the W&S anode high amplification factor is necessary – Use of two MCPs in chevron geometry– High electron density in the second MCP– Short life time of the MCPs– Limitations on beam current– Protection screen is installed – Triggering of the MCP power supply is applied

• Using an MCP with a phosphor screen is probably the best way to build a position sensitive detector for IPM

Page 26: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 26

Laser profile monitor

• Laser induced luminescence (for ions) in connection with laser cooling (ASTRID…)– Watching the light using a camera

• Photo-neutralization for H- beam (LANL, BNL, ORNL…)– A tightly focused laser beam is directed

transversely through the beam, causing photo-neutralization.

– Scanning the ion beam with the laser and simultaneously measure the beam current

Page 27: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 27

PM based on light radiation of residual gas, exited by the beam

particles

Page 28: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 28

Spectral analysis of the beam signals

-signals of a pick-up in frequency domain give a lot of information– Exiting the beam und measuring the

betatron frequencies gives the tune– Stability information can be obtained

using the Beam Transfer Function (BTF) method

– Electron cooling improves S/N ratio

Page 29: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 29

Example of the beam spectrum at COSY

Vertical delta signal

Page 30: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 30

Vertical BTF

Page 31: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 31

Transverse stability diagram

Imaginary part[relative units]

Z

Real part[relative units]

Page 32: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 32

Longitudinal BTF at COSY

600 466.67 333.33 200 66.67 66.67 200 333.33 466.67 6001300

1033.33

766.67

500

233.33

33.33

300

566.67

833.33

1100

1366.67

1633.33

1900

2166.67

2433.33

0,8 mA2,7 mA4,5 mA

Stability Diagram

Real part

Imag

inar

y pa

rt

0

0

For different

proton beam

currents:

0,8 mA

2,7 mA

4,5 mA

Page 33: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 33

Transverse BTF at COSY

2.01 104

1.41 104

8174.4 2216.6 3741.2 9699

4.66 104

2.41 104

1672

2.08 104

4.32 104

6.57 104Stability Diagram

Real Part[Ohm/m]

Imag

inar

y pa

rt [

Ohm

/m]

Beam current:3,2 mA2,5 mA

Page 34: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 34

Summary

• Electron cooling gives much better S/N ratios– Schottky diagnostics is a very powerful method– Schottky spectra of an e-cooled ion beam

might be strongly distorted– BTF, longitudinal and transverse– Online BTF measurement should be further developed

• Profiles of an e-cooled ion beam are difficult to measure– Better resolution is needed– Life time of MCPs

• For new machines diagnostic must be planed together with the machine design

Page 35: Diagnostics for intense e-cooled ion beams by Vsevolod Kamerdzhiev Forschungszentrum Jülich, IKP, COSY ICFA-HB2004, Bensheim, October 19, 2004

ICFA-HB2004 35

Thank you