DOC# 14121 REV B CN #687 7-10-14 Diagnosys LLC • 175 Cabot Street • Suite 500 • Lowell, MA 01854 USA • (978) 458-1600 Diagnosys UK Ltd • 54 Impington Lane Impington • Cambridge, CB49NJ England • +44(0) 1223 520699 www.diagnosysllc.com Diagnosys Ultra-widefield mfERG Industry leading funconal diagnoscs for the private pracce Diagnosys LLC, the industry leader in ophthalmic electrophysiology for over thirty years, presents the first Mulfocal Electrorenography (mfERG) system tailored for use in the private pracce. The mfERG has been well documented to aid in the diagnosis and monitoring of renal disorders such as Diabec Renopathy, Age-Related Macular Degeneraon and Renotoxic drug screening. Objecve Most sensive objecve funconal test for maculopathy Simplisc interpretaon aids in streamlined paent care Funconal Correlates funconal test results with structural tests such as OCT and fundus photography Increases sensivity and specificity in the diagnosis of maculopathies when combined with other diagnosc tests Vision Tesng Quick and easy protocols maximize paent flow Normave data and all soſtware updates included AAO-preferred method for drug toxicity screening Both eyes may be tested simultaneously Ultra-widefield smulus (90 degrees) Industry-first 32-bit amplifier provides unmatched signal resoluon

Upload: others

Post on 29-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Diagnosys Ultra-widefield mfERGdiagnosysllc.com/files/Diagnosys LLC Interpretation Samples-Web.pdfGM IIF D FMNP PP P D IR D E D GM IP D P IM P FMN FE M DEE Diagnosys Ultra-widefield

DOC# 14121 REV B CN #687 7-10-14

Diagnosys LLC • 175 Cabot Street • Suite 500 • Lowell, MA 01854 USA • (978) 458-1600Diagnosys UK Ltd • 54 Impington Lane Impington • Cambridge, CB49NJ England • +44(0) 1223 520699

www.diagnosysllc.com

Diagnosys Ultra-widefield mfERGIndustry leading functional diagnostics for the private practice

Diagnosys LLC, the industry leader in ophthalmic electrophysiology for over thirty years, presents the first Multifocal Electroretinography (mfERG) system tailored for use in the private practice.

The mfERG has been well documented to aid in the diagnosis and monitoring of retinal disorders such as Diabetic Retinopathy, Age-Related Macular Degeneration and Retinotoxic drug screening.

Objective•Most sensitive objective functional test for maculopathy•Simplistic interpretation aids in streamlined patient care

Functional•Correlates functional test results with structural tests such as OCT and fundus photography• Increases sensitivity and specificity in the diagnosis of maculopathies when combined with other diagnostic tests

Vision Testing•Quick and easy protocols maximize patient flow•Normative data and all software updates included •AAO-preferred method for drug toxicity screening•Both eyes may be tested simultaneously•Ultra-widefield stimulus (90 degrees)• Industry-first 32-bit amplifier provides unmatched signal resolution

Page 2: Diagnosys Ultra-widefield mfERGdiagnosysllc.com/files/Diagnosys LLC Interpretation Samples-Web.pdfGM IIF D FMNP PP P D IR D E D GM IP D P IM P FMN FE M DEE Diagnosys Ultra-widefield

DOC# 14121 REV B CN #712 3-9-15

Diagnosys LLC • 175 Cabot Street • Suite 500 • Lowell, MA 01854 USA • (978) 458-1600Diagnosys UK Ltd • 5 Trust Court, Chivers Way, Vision Park • Histon • Cambridge, CB24 9PW UK • +44(0) 1223 520699

www.diagnosysllc.com

Normal mfERG Response:

• All ring average responses within normal ranges for both amplitude and implicit time

• Trace array consistent with normative data

• ‘Volcano-shaped’ 3D plot represents healthy macular response with good fixation

Abnormal mfERG Response (Plaquenil Toxicity):

• Degradation in 2nd ring response OU demonstrates paracentral functional loss found in bull’s-eye maculopathy

• Updated American Academy of Ophthalmology screening guidelines for plaquenil toxicity specifically recommends multifocal ERGs as they “objectively evaluate function and can be used in place of visual fields”

• Parafoveal functional degradation illustrated by trace arrays and 3D plots allows practitioners to discontinue retinotoxic drugs and limit both functional and structural losses

Page 3: Diagnosys Ultra-widefield mfERGdiagnosysllc.com/files/Diagnosys LLC Interpretation Samples-Web.pdfGM IIF D FMNP PP P D IR D E D GM IP D P IM P FMN FE M DEE Diagnosys Ultra-widefield

DOC# 14121 REV B CN #712 3-9-15

Diagnosys LLC • 175 Cabot Street • Suite 500 • Lowell, MA 01854 USA • (978) 458-1600Diagnosys UK Ltd • 5 Trust Court, Chivers Way, Vision Park • Histon • Cambridge, CB24 9PW UK • +44(0) 1223 520699

www.diagnosysllc.com

Abnormal mfERG Response (dry AMD):

• Degraded central response OU outside normal limits for both amplitude and implicit time

• 2nd and 3rd ring responses OU show borderline results in both trace array and group averages

• 4th and 5th ring responses OU and trace array quantify residual parafoveal function

• Absent ‘volcano-shaped’ 3D plot represents loss in foveal response

Abnormal mfERG Response (wet AMD):

• Degraded central response OD outside normal range for both amplitude and implicit time (OS response within normal limits)

• 2nd and 3rd ring responses OD show borderline results in both trace array and group averages

• 4th and 5th ring averages and trace arrays OU validate and quantify residual parafoveal function

• Absent ‘volcano-shaped’ 3D plot represents total loss in foveal functional response OD

Page 4: Diagnosys Ultra-widefield mfERGdiagnosysllc.com/files/Diagnosys LLC Interpretation Samples-Web.pdfGM IIF D FMNP PP P D IR D E D GM IP D P IM P FMN FE M DEE Diagnosys Ultra-widefield

DOC# 14121 REV B CN #712 3-9-15

Diagnosys LLC • 175 Cabot Street • Suite 500 • Lowell, MA 01854 USA • (978) 458-1600Diagnosys UK Ltd • 5 Trust Court, Chivers Way, Vision Park • Histon • Cambridge, CB24 9PW UK • +44(0) 1223 520699

www.diagnosysllc.com

Abnormal mfERG Response (Diabetic Retinopathy, NP):

• Ring averages quantify functional responses for longitudinal analysis

• Trace array and 3D plot OU provide geographic evidence of retinal dysfunction that may precede vascular changes

Abnormal mfERG Response (Proliferative DR):

• Ring averages quantify functional responses for longitudinal analysis

• Trace array and 3D plots illustrate clear functional degradation OU compared against normative data and non-proliferative cases, as well as geographic evidence of retinal dysfunction