Measuring Air Flow, Energy Use, and Static Pressure in a Variety of As-Installed Conditions
![Page 2: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/2.jpg)
The Test Setup
![Page 3: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/3.jpg)
Panasonic Whisper GreenFan Controls
• Dial-in CFM• Timer not visible to homeowner
![Page 4: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/4.jpg)
Metering
![Page 5: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/5.jpg)
Variables
• Duct type (metal flex, sheet metal)• Elbow placement (immediate, 2-3’)• Flap (open, screwed shut)• Termination (forced passive, duct roof vent)• Grille (with, without)• Installation type (perfect, small oops, they
probably won’t catch this mistake)
![Page 6: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/6.jpg)
Baseline and Ideal
• Baseline– No duct, open flap, with grille– 136 CFM, 1.5 Pa, 10 Watt
• Ideal– 2 feet straight before elbow, 5 feet
up to roof duct vent termination– 143 CFM, 45 Pa, 19.8 Watt
![Page 7: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/7.jpg)
Duct Type
• No change between metal flex and sheet metal in ideal setup– 141 CFM, 22-24 Pa, 15 Watt
![Page 8: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/8.jpg)
Changing the Termination
• Passive attic vent used as duct termination– Shove it in and seal it– 142 CFM, 22.2 Pa, 14.8 Watt
• Duct roof vent– Meets code– 143 CFM, 45.0 Pa, 19.8 Watt– As a note, running fan 24/7 at this rate is
<$20/year
![Page 9: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/9.jpg)
Real-world Duct Run
• We have a ladder and a phantom truss in the way!– CFM increased
slightly (5 CFM)– Static pressure
doubled to 46 Pa– Energy increased
slightly, up to 21 Watt
![Page 10: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/10.jpg)
Damper
• With the same realistically awkward duct run, now tape the damper shut (but that never happens in real life)– CFM dropped almost in half, but still pulled 87
CFM– Static pressure jumped
from 46 Pa to 128 Pa– Watts increased slightly,
from 21 to 23 Watts
![Page 11: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/11.jpg)
Calibrated Crush
• The “small oops” scenario– Damper open, but complex duct run– No change in CFM– Static increases from
46 Pa to 60 Pa– Watts increase from
21 to 24
![Page 12: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/12.jpg)
Maybe They Won’t Notice
![Page 13: Did Panasonic Make a Contractor-Proof Bath Fan ?](https://reader036.vdocument.in/reader036/viewer/2022062501/56815e49550346895dccbf19/html5/thumbnails/13.jpg)
Maybe They Won’t Notice
• Still pulled 57 CFM• 140 Pa• Only 20 Watt