DIFFERENCE BETWEEN RNC 3810 AND RNC 3820By-
Mohit KumarEILL [email protected]
DIFFERENCE BETWEEN RNC 3810 AND RNC 3820
RNC 3810Consists of one or two cabinets.Each cabinet contains one to three sub racks.Has one MS, located in the Main Cabinet.The capacity of the RNC is increased by connecting ESs to the MS.built on a common platform and connected in a star topologyMaximum ES that can be connected = 5 (F configuration)
A - Power ConnectionsB - Extension SubracksC - Main SubracksD - ICF - Interface connection field
ConfigurationsA - 1 MSB - 1 MS + 1 ESC - 1 MS + 2 ESD - 1 MS + 3 ESE - 1 MS + 4 ESF - 1 MS + 5 ES
RNC 3820Consists of one cabinetA cabinet contains one to three subracks.An RNC has one MS located at the bottom of the cabinet.The capacity of the RNC is increased by connecting ESs to the MS.built on a common platform and connected in a star topologyMaximum ES that can be connected = 2
A - Extension SubrackB - Main SubrackC - APP - Active Patch Panel
ConfigurationsA - 1 MSB - 1 MS + 1 ESC - 1 MS + 2 ES
C-pack - Capacity Card Package1 GPB board 2 SPB boards
O-pack - Optimization Card Package1 GPB board
The hardware structure remains same for both the RNC's
RNC 3810
RNC Hardware Structure – Multiple Subracks
RNC 3820
RNC 3820 Hardware Structure – Multiple Subracks
SXB is not present in RNC 3820
An RNC always includes an MS. The MS interconnects all other subracks in theRNC and includes all functions of an ES as well as functions common to the RNC
RNC 3810
MS Functions• Termination of the Mur interface with OSS-RC• Termination of the Iu interface with the CN• Termination of the Iur interface with another RNC• Termination of the Iub interface with the RBSs• Distribution of broadcast information to all involved subracks• Distribution of broadcast information to all involved RBSs within subrack• External transmission interfaces• Attachment of synchronization sources• Duplicated non-blocking Cell switch• Duplicated high-speed links to interconnect with the ESs• Duplicated timing signals for the node• Input for GPS signals• Pool of processors for user plane processing and control
ES Functions
• Termination of the Iub interface with the RBSs• Distribution of broadcast information to all involved RBSs within subrack• External transmission interfaces• Duplicated high-speed links between subracks and the MS• Duplicated non-blocking Cell switch• Pool of processors for user plane processing and control
RNC Modules
• One General Purpose Processor Board (GPB)• A set of dynamically allocated Special Purpose Processor Modules (SPMs)• A set of semi-static allocated Iub Links, that is connections to RBSs• Supporting software
LEGEND -
RNC 3820
MS Functions• Termination of the Mur interface with OSS-RC• Termination of the Iu interface with the CN• Termination of the Iur interface with another RNC• Termination of the Iub interface with the RBSs• Distribution of broadcast information to all involved subracks• Distribution of broadcast information to all involved RBSs within a subrack• External transmission interfaces• Attachment of synchronization sources• Duplicated non-blocking cell switch• Duplicated high-speed links to interconnect with the ESs• Duplicated timing signals for the node• Input for GPS signals• Pool of processors for user plane processing and control
ES Functions
• Termination of the Iub interface with the RBSs• Distribution of broadcast information to all involved RBSs within subrack• External transmission interfaces• Duplicated high-speed links between subracks and the MS• Duplicated non-blocking Cell switch• Pool of processors for user plane processing and control• Termination of the Iu interface with the CN
RNC Modules
• One General Purpose Processor Board (GPB)• A set of dynamically allocated Special Purpose Processor Modules (SPMs)• A set of semi-static allocated Iub Links, that is connections to RBSs• Supporting software
SAMEDIFFERENT
Subrack Equipment The MS and ES can each house up to 28 boards
RNC 3810
SLOT NO. RNC 3810 FUNCTIONALITY
1 SCB3 Power IN , 4 ports to connect ES.
2 SXB(m) To connect an Extra ES.
3 SXB(r) Same as above - for redundancy purpose
4 TUB(m) For Synch and Clock Pulse.
5 TUB(r) Same as above - for redundancy purpose
6 ET/DUMMY
7 ET/DUMMY
8 GPB (m)
9 GPB(r)
10 GPB(m) MAIN PROCESSOR
11 GPB(r)
12 GPB (m) Operation and Maintenance
13 GPB (r)
14 GPB RNC MODULE (IN POOL)
Towards CN - For UP
Redundancy - Towards CN - For UP
Towards CN - For CP (SCCP)
Redundancy - Towards CN - For CP
Redundancy - MAIN PROCESSOR
Redundancy - Operation and Maintenance
15 GPB RNC MODULE (IN POOL)
16 GPB RNC MODULE (IN POOL)
17 GPB RANAP
18 GPB
19 SPB RNC MODULE (IN POOL)
20 SPB RNC MODULE (IN POOL)
21 SPB RNC MODULE (IN POOL)
22 SPB RNC MODULE (IN POOL)
23 SPB RNC MODULE (IN POOL)
24 SPB RNC MODULE (IN POOL)
25 ET/DUMMY IUB CONNECTIVITY
26 ET/DUMMY IUB CONNECTIVITY
27 ET/DUMMY IUB CONNECTIVITY
28 SCB(r) Redundancy - Power IN , 4 ports to connect ES.
Redundancy - RANAP
RNC 3820SCB- DF
TUB
CMXB
ET-IPG
GPB
GPB
GPB
GPB
SPB
SPB
GPB
ET-IPG
SPB
SPB
ET-IPG
GPB
SPB
SPB
ET-MF4
ET-MF4
ET-MF4
GPB
SPB
GPB
ET-IPG
CMXB
TUB
SCB- DF
RNC 3820
FUNCTIONALITY
Power IN , 4 ports to connect ES.
For Synch and Clock Pulse.
connectivity for internal and external user-plane traffic
ET- For IP connectivity
MAIN PROCESSOR + Operation and Maintenance
RNC MODULE (IN POOL)
RANAP, RNSAP, SCCP
RNC MODULE (IN POOL)
RNC MODULE (IN POOL)
RNC MODULE (IN POOL)
RNC MODULE (IN POOL)
ET- For IP connectivity
RNC MODULE (IN POOL)
RNC MODULE (IN POOL)
ET- For IP connectivity
RNC MODULE (IN POOL)
RNC MODULE (IN POOL)
RNC MODULE (IN POOL)
ET - For ATM Connectivity
ET - For ATM Connectivity
ET - For ATM Connectivity
Redundancy - RANAP, RNSAP, SCCP
RNC MODULE (IN POOL)
Redundancy - MAIN PROCESSOR + Operation and Maintenance
ET- For IP connectivity
redundancy - For Synch and Clock Pulse.
redundancy - Power IN , 4 ports to connect ES.
redundancy for inter-subrack Ethernet communication, each subrack is equipped with two CMXB boards.
redundancy - connectivity for internal & external UP traffic
EXTENSION SUBRACK
RNC 3810
Total Numbers of GPB - Total Numbers of SPB - works in pool
RNC 3820
3810 38206 4
10 9
RNC 3810
RNC 3820
Iu/Iur is to terminated to ET on MS
`
Iu/Iur can be terminated to ET on MS or ES
Board
Other changes
TUB's have been moved to slots 2 and 27 in Main Subrack ESL carries user plane traffic between subracksCMXB & ET-IPG replaces ET-MFG. CMXB & ET-IPG connect through the Ethernet switchboard (ESL) on the back plane. ET-IPG in MS can be used for Iu-Cp & Iu-Up termination (refer to MO Structure). ET-IPG in ES-1 & ES-2 can be used for Iu-Up termination, but not Iu-Cp (refer to MO Structure).
›SXB›SCB›ET-MFG›ET-MC1, ET-MC41›ET-MX12, ET-MX13›ET-M1, ET-M3, ET-M4›SCB-DF›GPB7›CMXB›ET-IPG›TUB›SPB3›ET-MF4›ET-MF41
Status
- Replaced - Replaced - Replaced - Replaced - Replaced - Replaced - New - New - New - New - Moved position - Same - Same - Same
SCB - DFSwitch core board - dual feed
• Provides switch functionality (interface toward the switch core).• Distributes system synchronization.• Provides the ISL interfaces for connection between subracks.• Provides power to the subrack, and in some cases to the fan unit.• Controls the nearest CMXB, if present in the subrack. If an SCB-DF isfaulty or is removed from the subrack, the nearest CMXB ceases to workwithin 90 seconds.
LED1 PORT 03 PORT 24 PORT 3
CMXBCommon Main Switching Board
The CMXB is a 20-port 10G BASE-CX4 Ethernet Switch that provides eightfront-panel electrical Ethernet ports for user-plane data to and from the subrack,and 12 backplane Ethernet ports for device boards in a subrack.
provides 10G BASE-CX4 connectivity for internal and externaluser-plane traffic with redundancy between device boards in the same ordifferent subracks.
The board is controlled (Ethernet and Reset) by the adjacent Switch ControlBoard - Dual Feed (SCB-DF) through a point-to-point 1G Ethernet SerDesInterface (MMEL)
RNC 3810
RNC 3810 moshell log
RNC 3820 moshell log
RNC 3820
In 3810 we have ethernetswitchport
In 3820 we have ethernetswitchmoduleport
RNC 3810Cabinets 2
Subracks 6
Board Placement Fixed
ISL 310 Mbps
ESL NA
ATM backplane 630 Mbps
Ethernet Backplane NA
Optimized for ATM
Supports IP
Subrack Capacity 800W
Switching Low capacity ethernet
RNC 38201
3
Flexible
310 Mbps
10 Gbps
630 Mbps
10 Gbps
IP
ATM
1500W
High capacity Internal
RNC 3810 bo command ("board overview")
RNC 3820 bo command ("board overview")
Advantages
›Iu and Iur user plane can now be terminated in extension subracks ES-1 and ES-2. ›Inter-subrack user plane capacity increased with 10 Gb/s ESL (Ethernet Subrack Link) connections. ›New SCB-DF (Switch Core Board Dual Feed) power supply. ›RNC 3820 introduces 10 Gb Ethernet on external physical interface (Iu, Iur, Iub) via CMXB and APP (Active Patch Panel). ›Supports interface types 10G BaseT and Optical (via SFP modules) ›New RNC Module Identity (rncModule) based on subrack and slot position. ›Introduces new black box configuration when adding an IP based RBS. The operator does not need to define a referred subrack.