5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 1 Mayor Michael L. Montandon City Manager Gregory E. Rose Council Members William E. Robinson Stephanie S. Smith Shari Buck Robert L. Eliason Utilities Department - David H. Bereskin, P.E., Director Engineering Services Division 2829 Fort Sumter Dr North Las Vegas, Nevada 89030 Telephone: (702) 633-1276 Fax: (702) 649-9784 • TDD: (800) 326-6868 www.cityofnorthlasvegas.com Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards The City of North Las Vegas has adopted geographical information system (GIS) technologies to store, manage and maintain geographic/spatially-related data. Likewise, the majority of the civil engineering community has evolved to the point where the predominating design environment is computer aided design and drafting (CAD). It is the goal of the City to use GIS and CAD technologies to expedite the design and review processes within the administration, by developing standards and procedures for integration of digital engineering CAD drawings into the GIS environment maintaining the integrity and positional accuracy of the data. Digital Data submittals are required for both the Final Construction Plans and Hydraulic Network Analyses. Digital Utility Plan Submittal Summary Digital submittals shall conform to the following: 1. Include one comprehensive Utility plan in a *.dwg format in model space showing all project Utilities on one sheet. 2. Ensure that the Utility Plan is inserted into the correct location of the parcel data contained in Appendix Three (State Plan Coordinates). Note that no other plans in the set are required to be in State Plan Co-ordinates. 3. Water, Sewer and Storm Drain layers in the Auto Cad drawing shall be colored blue for water, green for sewer or orange for Storm and named correctly per Appendix Two. Each layer shall clearly indicate the pipe size and/or the type of appurtenance. 4. Include a Plan set layout (Key Map Overlay) of all Utility sheets in the encompassing project per Appendix Three, Figure 4. 5. Include an electronic version of the Hydraulic Network Analysis if required by the scope of the project. Note: The main purpose of this digital submittal project is that the Industry draws a pipeline or appurtenance once in the lifecycle of the project. The City intends to map all offsite and onsite facilities. This data would then be available in a digital format to customers/clients resulting in a more efficient and effective process/program for sharing digital data to the community. * This summary needs to be read in conjunction with the Digital Plan Requirements document at http://www.cityofnorthlasvegas.com/Departments/Utilities/PDFs/EngineeringServices/DigitalDataSumittal.pdf . * This summary is subject to change without notice.

Upload: lydiep

Post on 19-Jul-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 1

Mayor

Michael L. Montandon City Manager

Gregory E. Rose Council Members

William E. Robinson Stephanie S. Smith

Shari Buck Robert L. Eliason

Utilities Department - David H. Bereskin, P.E., Director

Engineering Services Division • 2829 Fort Sumter Dr • North Las Vegas, Nevada 89030 Telephone: (702) 633-1276 • Fax: (702) 649-9784 • TDD: (800) 326-6868

www.cityofnorthlasvegas.com

Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards The City of North Las Vegas has adopted geographical information system (GIS) technologies to store, manage and maintain geographic/spatially-related data. Likewise, the majority of the civil engineering community has evolved to the point where the predominating design environment is computer aided design and drafting (CAD). It is the goal of the City to use GIS and CAD technologies to expedite the design and review processes within the administration, by developing standards and procedures for integration of digital engineering CAD drawings into the GIS environment maintaining the integrity and positional accuracy of the data. Digital Data submittals are required for both the Final Construction Plans and Hydraulic Network Analyses. Digital Utility Plan Submittal Summary Digital submittals shall conform to the following: 1. Include one comprehensive Utility plan in a *.dwg format in model space showing all project Utilities on one sheet. 2. Ensure that the Utility Plan is inserted into the correct location of the parcel data contained in Appendix Three (State Plan Coordinates). Note that no other plans in the set are required to be in State Plan Co-ordinates. 3. Water, Sewer and Storm Drain layers in the Auto Cad drawing shall be colored blue for water, green for sewer or orange for Storm and named correctly per Appendix Two. Each layer shall clearly indicate the pipe size and/or the type of appurtenance. 4. Include a Plan set layout (Key Map Overlay) of all Utility sheets in the encompassing project per Appendix Three, Figure 4. 5. Include an electronic version of the Hydraulic Network Analysis if required by the scope of the project. Note: The main purpose of this digital submittal project is that the Industry draws a pipeline or appurtenance once in the lifecycle of the project. The City intends to map all offsite and onsite facilities. This data would then be available in a digital format to customers/clients resulting in a more efficient and effective process/program for sharing digital data to the community. * This summary needs to be read in conjunction with the Digital Plan Requirements document at http://www.cityofnorthlasvegas.com/Departments/Utilities/PDFs/EngineeringServices/DigitalDataSumittal.pdf. * This summary is subject to change without notice.

Page 2: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 2

Electronic Plan Requirements Beginning March 01, 2005, the Utilities Department has required a Compact Disk containing electronic drawing files when submitting construction plans on Mylars. These “Final Construction Plan” (Mylar) submittals shall include an electronic copy on Compact Disk (CD) or (DVD) of the plan set in AutoCAD format conforming to City standards. The copy shall include the plan as developed in model space, and all associated sheets in paper space as submitted on the final approved Mylar plan set. Plan View A Plan View of the affected construction area shall be submitted in one encompassing drawing file. It is understood that engineering design is completed in a drawing (digital file) that includes several plan and profile drawing sheets. When the digital file is submitted to the City in the same format as used for the design, it can not logically be imported into the GIS unless the standards for the coordinate system and layer naming convention are used. See Figure 03. Plan Set Layout A Plan Set layer shall show the individual plan of each geo-referenced individual plan sheet extents. See Figure 04 and Figure 05. Project Setup The drawing shall be submitted in State Plane coordinates with two points of geodetic control for spatial reference. All drawings must be geo referenced to the US State Plane coordinate system, NAD 83, East Zone 2701, US Survey Feet. All drawings must contain two reference survey markers (pins) tied to the existing “Clark County” horizontal and vertical datum. The control points shall be shown on the plans with associated Northing, Easting, and Elevation attributes. Hydraulic Network Analysis Digital files are also required for the Hydraulic Analyses performed for the Maximum Day, Peak Hour and Maximum Day plus Fire Flow conditions. The Hydraulic Analyses digital files together with the junction and pipe reports shall be complete with all elevations, lengths, diameter, material, roughness, hydraulic gradelines and all other data required to perform hydraulic analyses. Model Space The drawing must be drawn in at full scale (1:1). Any additional items that help define the model or add model data such as details, schedules or sections must also be drawn full scale in model space. Consistency in keeping related model elements in model space along with proper layer assignments will allow the use of x-refs and the ability to keep information dynamic and updated among disciplines. File Management All/Any XREFs within the drawing file MUST BE INSERTED/BOUND TO THE DRAWING FILE. Please send a separate file containing only the proposed utility information required. See CNLV Standards Drawing Note Tab for details.

Page 3: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 3

For every individual printed sheet of the drawing, there must be an individual, archivable DWG file. DO NOT place multiple sheets within one .DWG file. All digital files are required to be supplied on CDROM or DVD Media only. Other media forms are NOT acceptable. Standard Sheet Sizes and Formats All sheet sizes are to be ARCH D Plot – 24” x 36” (preferred format). Standard Symbols/Blocks Standard Symbols shall be used to reduce drafting time, increase legibility and conserve space. Symbols must be consistent throughout the plan set in accordance with City of North Las Vegas standards as outline in the schedules. All blocks shown are standard AutoDesk blocks. (Provided by the City of North Las Vegas Utilities Department). All blocks and line types will require object data fields to be completed. Vectorized fill patterns are discouraged as they make files unnecessarily large. All consultants are responsible for keeping file sizes within manageable limits. Questions All questions should be directed to Wayne Lindsay, Utilities Mapping Supervisor, Utilities Department, City of North Las Vegas, 2829 Fort Sumter Drive, North Las Vegas, NV 89030. Email: [email protected]. Telephone: (702) 633-1898. General Construction Notes General notes may be shown on the plan to explain all attributes associated to facility material used for the project example:

1. All fire hydrant laterals are 6” PVC unless otherwise noted. 2. All pipe is PVC C900 3. All blow-off valves installed comply with U.D.A.C.S Standards plate No.4 unless otherwise

specified. Quantities Report required per project A quantities report is required for each project listing all quantities and number of individual facilities installed. This includes size and number of valves, blowoffs etc. General Requirements

a) All design drawings must be geo referenced to the US State Plane coordinate system, NAD 83, East Zone, US Survey Feet. All drawings must contain two reference survey markers (pins) tied to the City of North Las Vegas GPS monument network. b) All features depicted in the design drawings must be surveyed after construction. City of North Las Vegas will spot check all coordinates to ensure accuracy. Table 1 specifies the features that must be surveyed. Water system features must be surveyed at a horizontal accuracy of ≤ 0.3 ft and vertical accuracy of ≤ 0.5 ft. Sewer system features must be surveyed at a horizontal accuracy of ≤ 0.5 ft and a vertical accuracy of ≤ 0.1 ft. c) The following feature geometry types must be shot directly using the survey instrument and tied to the City of North Las Vegas monument network:

i) All point features (hydrants, valves, sewer manholes, etc.), ii) All line features at all endpoints, bends, and turns (pipes, etc.), iii) All polygon features at all corners and bends (project boundaries, lots, right-of-ways, etc.)

Page 4: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 4

d) The following feature types are acceptable: Line, Polyline, Text, and Insert. Any other features such as Leaders, Blocks, etc. should not be present on the standard City of North Las Vegas CAD layers. e) City of North Las Vegas will provide a template (or seed) drawing files upon request. f) The project boundary must be labeled on the PROJECT_BOUNDARY_TEXT layer, and the label must be within the extent of the project boundary.

Layering:

a) Layer names for required layers must appear exactly as in Appendix Table 1. The base layers are provided in the CNLV Standards File(s). b) All required layers listed in the CAD layers must contain only the features that are described for that layer. For example, the B-BNDY-CNLV layer must only contain the boundary line and not such features as north arrows or parcels. c) All required layers must be present in the drawing except for features that do not pertain to a particular project. For example, some commercial projects or apartment complexes may not contain sewer taps as part of the construction and should not be included in the drawing. d) All layers must be clearly differentiated from each other.

i) Two layers having the names “C-WATR-PIPE-XXXX” and “C-WATR-PIPES-XXXX” should not exist in the same drawing. ii) C-SEWR-PIPE-XXXX and SEWER-PIPE should not exist in the same drawing. iii) C-SEWR-PIPE-0006 and C-SEWR-PIPE-0010 is preferred.

e) All text must appear on separate layers from the layers they annotate. For example, text describing a sewer line must be on the C-SEWR-ANNO layer, not the C-SEWR-PIPE-XXXX layer, or any other layer in the drawing. Map annotation templates are acceptable. f) Text leaders should be placed on the text layer, not the feature layer. For example, the leader for the diameter of a water pipe should be on the C-WATR-ANNO layer, not the C-WATR-PIPE-XXXX layer.

Drawing

a) All layers must conform to the proper geometry type (insert, line, polygon, text) as indicated in Table 1.

b) All Polygon type features must be completely closed. Lines may need to be duplicated on more than one layer.

i) Subdivision/project parcels must be to closed figures on their layer (not closed with the subdivision/project boundary). ii) Road edge-of-pavement and road right-of-way must be drawn as closed polygons. iii) Where a polygon feature extends beyond the edge of the plan, the property boundary (repeated on the polygon feature’s layer) will be used to close the polygon. iv) All edges on polygon features must be snapped together at the vertices. Gaps in polygon boundaries will not be accepted.

c) Sewer Features i) Sewer Lines and Sewer Taps need to be digitized with proper directionality: Lines must be drawn from the uphill node to the downhill node or flipped after the lines have been digitized. ii) All tangents between sewer manholes need to be drawn with a single line. Lines must not continue for more than one tangent. iii) All tangents must be snapped at endpoints intersecting at the exact center of the manhole. No gaps should exist between tangents. iv) Manholes need to be symbolized consistently with a circle centered exactly on the tangent endpoints.

Page 5: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 5

v) Sewer tap locations must be snapped to the sewer tangent and accurately placed. Placement should be based on direct survey of the tap where it connects to the sewer tangent, or based on the televising report. CCWA will verify tap placement against the televising report. Televising reports may be obtained from the CCWA inspector.

d) Water Features i) Water lines must be digitized with all straight-line pipes consisting of only two end points. Straight-line pipes will begin and end at the following features (nodes): hydrants, valves, meters, pumps, tees, crosses, and valves. Polylines should be used wherever a water line contains elbows or bends (i.e., when the line does make a straight run from node to node). ii) Curves may be digitized with enough vertices to capture the curve geometry, but they must be single, continuous lines. Curves or arcs may also be used to designate curved pipe. iii) Hydrants must be shown in their true, surveyed location, and must be connected to the water main via a valved fire hydrant line. iv) All water lines must be continuous, with pipe endpoints snapped to each other at endpoints (nodes). v) End-of-line caps must be drawn to differentiate end-of-lines from lines that extend beyond the extent of the drawing. Caps should be drawn for lines that are to be permanently capped when the project is complete, not for lines that are temporarily capped pending inspection.

Symbolization

a) Symbols must be standardized according to examples provided in the City of North Las Vegas Standards file(s). All “point” features must be symbolized using standard City of North Las Vegas CAD symbols and drawn as inserts. An example of “point” objects is as follows:

i) Vault ii) Valve iii) Hydrant iv) Manhole v) Meter vi) End of Line/Cap vii) Reducer viii) Drop Inlet vix) SD Manhole x) Sewer Manhole xi) Direction Flow xii) Storm Manhole xiii) Encasing xiv) Well xv) Drain xvi) Blowoff xvii) Air Vac xviii) Reservoir xvix) Mark Balls

This list is not to be taken as all inclusive.

Annotations see Appendix One a) Any non-standard water and sewer lines must be annotated as such. Line diameter, material, ownership, etc. that does not conform to standard practice should be noted in the corresponding annotation layer. For example, standard subdivision sewer lines are 8” in diameter. Any other diameter must be annotated on the C-SEWR-ANNO layer.

Page 6: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 6

b) All addresses and lot numbers must be number data type (that is no text or symbols (#, -, ft, _, “, ’, etc.)). If the lot does not have a number, this layer should be blank. c) All required text must be single line text. d) All annotation for polyline (polygon) features must be bounded by the polyline it annotates. For example, the project name must be within the project boundary, and not extend beyond it.

File naming and revisions.

The AM/FM/GIS/ Divisions have implemented the following standardized nomenclature for all record drawing files that are maintained by the Division. The new nomenclature is recognized by the City of North Las Vegas as the naming convention for all items relating to record drawings placed in Documentum and on the Repository.

Standardized Document Naming (SDN): Example: Project_Name_PH03_WL_004.ext Project Name Discipline Sheet Number Extension

STANDARD DISCIPLINE SHEET REFERENCE C CIVIL PLAN R DEMOLITION PLAN D DETAIL PLAN RW RIGHT OF WAY PLAN DI DROP INLET SECTIONS S STRIPE & SIGNAL PLAN E ELECTRICAL PLAN SD STORM DRAIN PLAN &

PROFILE EX EXHIBIT SL STREET LIGHT PLAN G GENERAL NOTES, COVER,

LEGEND, ABBREVIATIONS SM SIGNAL MODIFICATION PLAN

HC HORIZONTAL CONTROL SS SANITARY SEWER PLAN IG INTERSECTION GRADING PLAN TS TRAFFIC SIGNAL PLAN LS LANDSCAPE PLAN TY TYPICAL SECTIONS M MECHANICAL PLAN U UTILITY PLAN PP PLAN & PROFILE VIEW WL WATER LINE PLAN

Deliverable Format

a) All files will be delivered on single disk media in AutoCAD (a release currently supported by Autodesk subscription plans) or DGN format (for projects created in Microstation). CD Rom and DVD’s are the only acceptable media. Files should not be spanned over more than one disk. b) All deliverables will be labeled with the file name, company name, contact name, and phone number. A transmission letter restating this information along with a statement requesting design review will also accompany the disk.

Page 7: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 7

PROPOSED ADDITIONS AND CHANGES TO THIS CADD STANDARD This standard is intended to be updated and enhanced as appropriate over time. Recommended additions and suggested changes are to be directed to: Wayne Lindsay Utilities Support Supervisor Utilities Department City of North Las Vegas 2829 Fort Sumter Drive North Las Vegas NV 89030. Email: [email protected] Telephone: (702) 633-1898

Page 8: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 8

Appendix One Annotations

All design drawings shall record the following attributes for all installed facilities, structures, instruments and objects if applicable. Please note this sample list is not all inclusive and all items listed herein or in the submittal should be labeled as specifically as possible.

Water Annotations AIR/VACUUM VALVE BODY TYPE VAULT DETAIL MODEL NUMBER MANUFACTURER DIAMETER SURFACE ELEV. TYPE STD. DETAIL ALTITUDE VALVE SIZE STD. DETAIL TYPE INVERTS MANUFACTURER MODEL NUMBER DISCHARGE INFO BACKFLOW MANUFACTURER SIZE TYPE VAULT DETAIL DCDA DETAIL RPPA DETAIL RPZBP DETAIL PVB DETAIL BLOWOFF SIZE INVERT TYPE MANUFACTURER STD. DETAIL MATERIAL MODEL NUMBER CAP SIZE INVERT MANUFACTURER TYPE FITTING TYPE CASING DIAMETER SIZE TYPE MANUFACTURER MATERIAL PURPOSE COMMENTS CATHODE SIZE TYPE SURFACE ELEV. COMMENTS ELEMENT TEST TYPE STD. DETAIL PROTECTION CLEANOUT STD. DETAIL SURFACE ELEV. MANUFACTURER DIAMETER INVERTS FIREHYDRANT TYPE MODEL NUMBER STD. DETAIL COMMENTS MANUFACTURER VALVE TYPE BURY SIZE MANHOLE STD. DETAIL MANHOLE # SURFACE ELEV. MANUFACTURER SIZE TYPE PROPERTY INVERTS MONITOR STATION STD. DETAIL TYPE SURFACE ELEV. COMMENTS TEST SCHEDULE PRV MANUFACTURER STD. DETAIL VALVE TYPE SIZE MODEL NUMBER SURFACE ELEV. VAULT OPERATION PUMP MANUFACTURER SIZE TYPE POWER RATING FLOW RATE INVERTS MODEL NUMBER STD. DETAIL SURFACE ELEV. VAULT BYPASS REDUCER STD. DETAIL INVERT THRU DIAMETERS MANUFACTURER MODEL NUMBER WATER_PIPE STD. DETAIL DIAMETER MANUFACTURER LENGTH MATERIAL PIPE CLASS LINING LOCATION TYPE WATERDRAIN STD. DETAIL SURFACE ELEV. INVERTS SIZE TYPE MANUFACTURER MODEL NUMBER

Page 9: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 9

WATERMETER STD. DETAIL SIZE TYPE MANUFACTURER MODEL NUMBER SURFACE ELEV. INVERTS MATERIAL WATERVALVE TYPE STD. DETAIL MODEL NUMBER COMMENTS SIZE MANUFACTURER FUNCTION CRITICAL SERVICE VAULT # TURNS WELL STD. DETAIL SIZE MATERIAL DEPTH CAPACITY PUMP INFO OPERATION DATE ZONE QUALITY TYPE USABLE DEPTH WATER IN/OUT MARKER BALLS TYPE DEPTH STD. DETAIL MANUFACTURER

Sewer Annotations

CAP SIZE INVERT MANUFACTURER TYPE FITTING TYPE MODEL NUMBER CASING DIAMETER SIZE TYPE MANUFACTURER MATERIAL PURPOSE MODEL NUMBER COMMENTS CLEANOUT STD. DETAIL SURFACE ELEV. MANUFACTURER DIAMETER LIFTSTATION STD. DETAIL PICKUP TYPE SURFACE ELEV. FLOW RATE SIZE TYPE PUMP INFO INVERTS MANUFACTURER MODEL NUMBER MANHOLE STD. DETAIL MANHOLE # SURFACE ELEV. MANUFACTURER SIZE TYPE PROPERTY INVERTS FLOWARROW DIRECTION SEWER_PIPE STD. DETAIL DIAMETER MANUFACTURER LENGTH MATERIAL PIPE CLASS LINING LOCATION TYPE

Storm Annotations ACCESS RAMP MATERIAL STD. DETAIL TYPE SIZE SLOPE CASING DIAMETER SIZE TYPE MANUFACTURER MATERIAL PURPOSE MODEL NUMBER COMMENTS CULVERT STD. DETAIL SIZE MATERIAL TYPE MANUFACTURER INVERTS Q EQUATION CAPACITY CURBINLET STD. DETAIL SIZE Q EQUATION TYPE MANUFACTURER SURFACE ELEV. INVERTS MODEL NUMBER GRATING DROPINLET STD. DETAIL SIZE Q EQUATION TYPE MANUFACTURER SURFACE ELEV. INVERTS MODEL NUMBER GRATING JCTBOX

Page 10: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 10

STD. DETAIL SIZE MANUFACTURER MODEL NUMBER TYPE Q EQUATION SURFACE ELEV. INVERTS LADDER MANUFACTURER MODEL NUMBER TYPE SIZE DETENTION BASIN SIZE CAPACITY ALTERNATE USE DRAIN RATE

General Annotations CNLV JOB TITLE DATE TYPE APN NUMBER PAGE NUMBER HANSEN NUMBER SECTION NUMBER GRID MARKER COMMENTS PROJECT ID JURISDICTION OWNERSHIP MATERIALS MANUFACTURER DATA SHEETS MISCELLANEOUS PLAN SET COMMENTS STATE PLANE WEB LINKS PRESSURE ZONE

Page 11: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 11

Appendix Two CAD Layers

Water Map Layers (BLUE) All Sewer layer are to be colored a shade of blue

Page 12: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 12

Sewer Map Layers (GREEN) All Sewer layer are to be colored a shade of green

Page 13: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 13

Storm Drain Layers All Sewer layer are to be colored a shade of magenta

Page 14: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 14

Other Layers Remaining layers are variable in color with Fire Layers Red

Page 15: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 15

Appendix Three Figures

Figure 01

City Limits, Section Grid

Page 16: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 16

Figure 02

City Limits with Parcels

Page 17: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 17

Figure 03

Example Submittal

Page 18: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 18

Figure 04

Key Map Overlay

Page 19: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 19

Figure 05 Sheet Detail Submittal

Page 20: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 20

Figure 06 CNLV Toolbar

Figure 07 CNLV Menu Drop Down

Page 21: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 21

Figure 08

CNLV Tool Palette

Page 22: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 22

Appendix Four

Standards File Notes Copy

Sheet 01, Example Submittal Notes

WELCOME TO THE CITY OF NORTH LAS VEGAS (CNLV) STANDARD FILE SET. THIS FILE SET IS DESIGNED TO FACILITATE COMPLIANCE WITH THE CNLV DIGITAL SUBMITTAL STANDARDS. THE ENCLOSED FILE SET HAS MANY COMPONENTS CREATED TO AID THE CONSULTANT WITH STANDARDS COMPLIANCE. PLEASE CONSIDER THIS FILE RELEASE VERSION 01. THIS DRAWING, CNLV_UTL_STD_C3D007.DWG OR DWT, IS THE CONSTRUCT OF THE UTILITY XREF. SAID DRAWING IS IN NEVADA STATE PLANE COORDINATES NV83-EF AND CONTAINS VARIOUS BOUNDARIES AND GRIDS FOR REFERENCE. PLEASE NOTE THERE IS INITIAL SETUP TIME INVOLVED IN CONFIGURING THE END USER'S WORKSTATION TO USE THE SUPPLIED TOOLS. THE FOLLOWING WILL DETAIL THE INSTRUCTIONS IN TWO PARTS. PART ONE WILL DETAIL THE INITIAL SETUP AND PART TWO WILL DETAIL THE INSTRUCTION SET AND GENERAL USE OF THE POST-CONFIGURED WORKSTATION. ALSO, THE LOADING OF SAID TOOLS IS NOT MANDATORY BUT HIGHLY SUGGESTED AS PRODUCTIVITY AND COMPLIANCE MAY BE COMPROMISED. TO CONFIGURE THE WORKSTATION FOR THE CNLV TOOLS PLEASE FOLLOW THE INSTRUCTIONS BELOW. IMPORT THE CNLV PROFILE 01. OPEN AUTODESK CIVIL3D_07 OR AUTODESK MAP 3D_07 (CURRENTLY TESTED PROGRAMS) 02. TYPE OPTIONS AT THE COMMAND PROMPT TO DISPLAY THE "OPTIONS" DIALOG BOX. 03. SELECT THE IMPORT BUTTON TO DISPLAY THE "IMPORT PROFILE" DIALOG BOX. 04. BROWSE TO THE FOLDER CONTAINING THE SUPPLIED "CNLV.ARG" FILE. 05. SELECT SAID FILE AND CHOSE OPEN TO IMPORT SAID FILE. 06. CHOOSE "SET CURRENT" THEN "OK" TO APPLY THE NEW SETTING. IMPORT THE CUSTOM USER INTERFACE FILE 01. TYPE "CUI" AT THE COMMAND PROMPT TO OPEN THE "CUSTOM USER INTERFACE" DIALOG BOX. 02. SELECT THE "TRANSFER TAB" 03. UNDER THE "CUSTOMIZATIONS IN NEW CUI FILE" PANE SELECT THE "OPEN CUSTOMIZATION FILE ICON" TO OPEN THE "OPEN" DIALOG BOX. 04. BROWSE TO THE SUPPLIED "CNLV.CUI" AND CHOSE OPEN TO DISPLAY THE "CUSTOMIZATIONS IN CNLV.CUI" PANE (RIGHT HAND PANE). 05. DRAG THE "CNLV" ICON DISPLAYED DIRECTLY UNDER "WORKSPACES" TO THE SAME LOCATION IN THE LEFT HAND PANE (CUSTOMIZATIONS IN MAIN CUI). 06. RIGHT CLICK ON THE IMPORTED "CNLV" WORKSPACE AND SELECT "SET CURRENT" AND SELECT "OK" 07. COPY THE CNLV_ICONS FOLDER TO THE ROOT OF THE C:\ DRIVE. IMPORT THE CUSTOM CNLV TOOL PALETTE 01. IF THE TOOL PALETTE IS NOT OPEN TYPE "CTRL+3" TO OPEN THE PALETTE. 02. AT THE BOTTOM OF THE TOOL PALETTE SELECT THE "PROPERTIES" ICON. 03. SELECT "CUSTOMIZE PALETTES" TO OPEN THE "CUSTOMIZE" DIALOG BOX.

Page 23: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 23

04. IN THE LEFT HAND (ALL PALETTES) PANE OF THE "CUSTOMIZE" DIALOG BOX RIGHT CLICK AND SELECT "IMPORT" TO OPEN THE "IMPORT PALETTES DIALOG BOX". 05. BROWSE TO THE SUPPLIED FOLDER FOR TOOL PALETTES AND IMPORT THE "SEWER.XTP, STORM.XTP AND THE WATER.XTP" FILES. 06. IN THE RIGHT HAND (PALETTE GROUPS) PANE OF THE "CUSTOMIZE" DIALOG BOX RIGHT CLICK AT THE ROOT LEVEL AND SELECT "IMPORT" TO OPEN THE "IMPORT GROUP" DIALOG BOX. 07. BROWSE TO THE SUPPLIED "TOOLPALLETES" FOLDER AND IMPORT THE "CNLV.XPG" FILE. 08. AFTER IMPORT RIGHT CLICK ON THE "CNLV" GROUP AND CHOOSE "SET CURRENT" THESE STEPS WILL CREATE SEVERAL CHANGES TO THE END USERS WORK ENVIRONMENT. THE CNLV PROFILE, UPON IMPORT, WILL CREATE A USER INTERFACE WITH A VARIETY OF C3D (CURRENTLY TESTED PRODUCT) TOOLS AND A MENU DESIGNED FOR GENERAL CIVIL WORK. THESE TOOLS ARE ORGANIZED IN GROUPS AND DISTRIBUTED EVENLY TO GIVE THE LARGEST WORKING WINDOW POSSIBLE. AS WITH ANY PROFILE IT CAN BE CUSTOMIZED TO EACH INDIVIDUAL'S NEEDS. THE CUSTOM USER INTERFACE FILE (CUI) CONTAINS TWO KEY FEATURES IN ADDITION TO THE AFORE MENTIONED WORKSPACE PROFILE. UPON IMPORT THERE WILL BE A NEW DROP DOWN MENU LOCATED ON THE FAR RIGHT SIDE OF THE MENU BAR. THIS MENU, NAMED "CNLV" CONTAINS A SERIES OF TOOLS SPECIFICALLY DESIGNED TO AID WITH STANDARDS COMPLIANCE. FURTHER, A NEW TOOLBAR WITH THE SAME TOOL SET, ALSO CALLED "CNLV" WILL BECOME AVAILABLE. A DETAILED DESCRIPTION OF THESE TOOLS WILL FOLLOW THE GENERAL DESCRIPTION OF THE CNLV TOOL PALETTES. THE CUSTOM CNLV TOOL PALETTE IS THE LAST PIECE OF CUSTOMIZATION. ONCE THE TOOL PALETTES HAS BEEN SUCCESSFULLY IMPORTED THE "CNLV" TOOL PALETTES WILL DISPLAY THE SAME CUSTOM TOOL SET AS THE AFORE MENTIONED MENU BAR AND TOOLBAR. THE DIFFERENCES OF ALL THREE ARE SPECIFIC TO THE DESIGNED FUNCTIONALITY OF EACH TYPE OF COMPONENT. THE MENU BAR TOOLS ARE STYLED IN THE STANDARD "DROP DOWN" FASHION WHILE THE TOOLBAR IS DESIGNED IN THE STANDARD "ICON" PATTERN. THE TOOL PALETTE IS DESIGNED TO DISPLAY THE TOOLS IN THREE SEPARATE TABS UNDER ONE "CNLV" HEADING. IMPORTANT, THE TOOL PALETTE REFERENCES AN EXTERNAL DRAWING AND NOT ITEMS WITHIN THE CURRENT DRAWING. THE PROPERTIES OF EACH TOOL MUST BE CHANGED TO POINT TO THE STORED "STANDARDS" FILE. THE TOOL PALETTE IS GOOD FOR POPULATING ANY DRAWING WITH CNLV BLOCKS. ONCE A BLOCK IS IMPORTED THE CORRELATING MENU AND TOOL BAR WILL BECOME AVAILABLE. EACH TOOL, INDEPENDENT OF THEIR DELIVERY METHODS, HAS A SPECIFIC PURPOSE. THERE ARE TWO DIVISIONS WITHIN THE STANDARD CNLV TOOL SET. THE FIRST DIVISION OF THE TOOL SET IS THE PIPE SET. PLEASE NOTE THESE TOOLS WILL NOT BE AVAILABLE OUTSIDE THE STANDARD FILE SET UNLESS THE APPROPRIATE LAYERS ARE IMPORTED FOR THE TOOLS TO WORK. THIS IS A SPECIFIC DESIGN FUNCTION. THE WATER, SEWER AND STORM PIPE PORTION OF THE TOOL SET TAKES ALL THE GUESSWORK OUT OF DRAWING UTILITY SPECIFIC OBJECT TYPES. SIMPLY SELECT THE WATER PIPE AND THE PROGRAM WILL DRAW A WATER PIPE OF THE CORRECT CAD OBJECT TYPE (PLINE) AND PLACE IT SEAMLESSLY ON THE CORRECT LAYER. THE SAME IS TRUE FOR BOTH THE SEWER AND STORM PIPES. PLEASE NOTE, THERE WILL BE MORE INFORMATION ON LAYER CONTROL IN A FUTURE SECTION. THE SECOND DIVISION IS THE BLOCK SET. WHETHER IT IS IN A MENU, TOOLBAR OR TOOL PALETTE THE BASIC OPERATIONAL FUNCTIONALITY IS THE SAME. TO INSERT A WATER

Page 24: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 24

BLOCK, NAVIGATE TO THE WATER BLOCK SECTION, SELECT THE APPROPRIATE BLOCK AND INSERT IT INTO THE DRAWING. THE BLOCK WILL BE INSERTED ON THE CORRECT LAYER AT THE USER SPECIFIED LOCATION. OBJECT DATA IS AVAILABLE FOR EACH INDIVIDUAL BLOCK TYPE. EACH TOOL HAS AN ICON AND DESCRIPTION ALLOWING EASY IDENTIFICATION. ALL OF THESE TOOLS SHOULD SIMPLIFY AND CREATE A PRACTICALLY ERROR FREE ENVIRONMENT FOR COMPLYING WITH CNLV STANDARDS. CNLV USES CAD LAYERS TO DIFFERENTIATE SIMILAR OBJECTS. THERE ARE MANY GENERALIZED LAYERS AVAILABLE FOR THE WATER, SEWER AND STORM ASSEMBLIES. THESE LAYERS AND THEIR USES ARE CHARACTERIZED BELOW. CNLV HAS ADOPTED AIA/ANSI CAD STANDARDS. THESE STANDARDS ARE ADOPTED BY LARGE GOVERNMENT AGENCIES SUCH AS THE U.S. AIR FORCE AND MAJOR CORPORATIONS SUCH AS INTEL AND UPS. UPON EXPLORING THE ENCLOSED LAYER LIST THE END USER WILL NOTICE THE BASICS SUCH AS C (CIVIL) AND G (GENERAL) IDENTIFIERS AS WELL AS MAJOR SECTIONS SUCH AS WATR (WATER) AND STRM (STORM). AT THE END OF MANY LAYER NAMES A USER MODIFIABLE "XXXX" IS AVAILABLE. THIS ALLOWS FLEXIBILITY FOR THE CONSULTANT TO HELP MAINTAIN THEIR INDIVIDUAL NEEDS. ALSO, THERE IS ROOM FOR EXPANSION IN THE ENCLOSED LIST AS LONG AS THE STANDARD NAMING CONVENTION IS MET AND LAYER PROPERTIES ARE APPROPRIATE. THE UNIVERSITY OF KANSAS (KU) HAS A LAYER GENERATOR THAT CAN ASSIST BUT NOT FULLY AID WITH NEW LAYER GENERATIONS. THE LINK IS MAINTAINED HERE: HTTP://FMIS3W.FMIS.KU.EDU/LAYERNAMER/DEFAULT.ASPX PLEASE NOTE THAT EXISTING DRAWINGS CAN BE CHECKED FOR COMPLIANCE USING THE SUPPLIED "CNLV_UTL_STD_C3D07.DWS" FILE. TO ENSURE QUALITY AND CONSISTENCY THE LAYER TRANSLATOR AND "CONFIGURE STANDARDS" DIALOG BOX IS USEFUL. THE SPECIFIC METHODOLOGY OF STANDARDS COMPLIANCE IS AT THE DISCRETION OF THE CONSULTANT. CITY OF NORTH LAS VEGAS UTILITY DEPARTMENT DISCLAIMER A STATEMENT OF UNDERSTANDING BETWEEN THE CITY OF NORTH LAS VEGAS UTILITY DEPARTMENT (CITY) AND ANY AND ALL SUBSEQUENT USERS OF INFORMATION OBTAINED HEREFROM: THE PLANS AND SUPPORTING INFORMATION IS FURNISHED BY THE CITY, AND IS ACCEPTED/USED BY THE RECIPIENT WITH THE UNDERSTANDING THAT THE CITY MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE ACCURACY, COMPLETENESS, RELIABILITY, OR SUITABILITY OF SAID PLANS OR ANY SUPPORTING DATA AND FURTHER UNDERSTANDS THAT ALL USERS ARE ACTING AT THEIR OWN RISK. THE CITY SHALL BE UNDER NO LIABILITY WHATSOEVER RESULTING FROM ANY USE OF THIS INFORMATION. THIS INFORMATION SHOULD NOT BE RELIED UPON AS THE SOLE BASIS FOR EXISTING WATER AND/OR SEWER LOCATIONS. THE ENGINEER SHALL CHECK AND VERIFY ALL DIMENSIONS AND LOCATIONS OF EXISTING UTILITIES. R & SEWER FACILITIES THE INFORMATION DELINEATED HERON WAS COMPILED FROM AVAILABLE RECORD DATA, NO LIABILITY IS ASSUMED FOR ACCURACY. THIS INCLUDES ALL PRINTS, EMAILS AND DOCUMENTS PROVIDED BY THE CITY OF NORTH LAS VEGAS. IF YOU HAVE ANY QUESTIONS OR COMMENTS, PLEASE CONTACT DANIELLE NEATH AT 702-633-2406 OR BY EMAIL. [email protected] OR WAYNE LINDSAY AT 702-633-1898, [email protected].

Page 25: Digital Plan Submittal Requirements - North Las Vegas, … · 2007-05-01 · Digital Plan Submittal Requirements Introduction: Digital Data Submission Standards ... efficient and

5/1/2007 J:\0Maps\CNLV_Standards\Documents\CNLV Electronic Plan Requirements.doc 25

Sheet 02, Example Submittal Notes

EXAMPLE NOTES: THIS SHEET, ALONG WITH ITS TITLE BLOCK IS FOR PRESENTATION PURPOSES ONLY. THIS EXAMPLE ILLUSTRATES THE GENERAL CONCEPT OF THE CNLV UTILITY SUBMITTAL. THIS IS NOT INTENDED TO CHANGE THE CONSULTANTS METHODOLOGY OF PROJECT SUBMITTALS, BUT TO PROVIDE A TEMPLATE FOR THE ADDITIONAL CNLV UTILITY SUBMITTAL. IT IS NECESSARY FOR THE CONSULTANT TO PROVIDE THIS PLAN TO COMPLY WITH THE STANDARDS. ASPECTS: THE KEY MAP GRID IS A NECESSARY ELEMENT OF THE CNLV UTILITY SUBMITTAL AS IT CORRELATES THE OVERALL UTILITY PLAN TO THE SUBMITTAL SHEET SET. THIS PROVIDES A MAP FOR GEOREFRENCING THE ACTUAL CIVIL PLAN SET INTO THE CNLV SPATIAL DATABASE. THE BACKGROUND PARCEL INFORMATION IS INCLUDED IN THE MODEL FOR REFERENCE ONLY AND IS NOT NECESSARY FOR SUBMITTAL. ALSO NOTE THE ABSENCE OF CERTAIN ITEMS. THERE ARE NO LABELS, NO DIFFERENTIATING LINE TYPES, NO EXISTING INFORMATION AND NO "ACTUAL" REPRESENTATION OF STORM PIPE WIDTH. THE IMPORTANT ITEMS ARE COLORS, LAYER CONTROL AND THE PROVIDED CNLV BLOCKS. SAID EXAMPLE IS PROVIDED FOR INFORMATION PURPOSES ONLY AND IS ENTERED INTO MODEL SPACE AS A BLOCK TO PROVIDE AN ADDITIONAL LEVEL OF PORTABILITY AND STUDY. THE BACKGROUND PARCEL INFORMATION IS PROVIDED FOR CONVENIENCE AND IS NOT NECESSARY FOR THE CNLV UTILITY SUBMITTAL.