dijet analyses for icd resolution and response

26
Dijet Analyses for Dijet Analyses for ICD Resolution and ICD Resolution and Response Response Barry Spurlock Barry Spurlock The University of Texas at The University of Texas at Arlington Arlington April 8, 2004 April 8, 2004

Upload: maverick-robertson

Post on 30-Dec-2015

24 views

Category:

Documents


0 download

DESCRIPTION

Dijet Analyses for ICD Resolution and Response. Barry Spurlock The University of Texas at Arlington April 8, 2004. OUTLINE. Motivation DPCC and How We Used It Data Analyses & Results Conclusions. Motivation. Dijet study of QCD background (P13) ICD-MG Task Force (ICD weighting factor) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Dijet Analyses for ICD Resolution and Response

Dijet Analyses for ICD Dijet Analyses for ICD Resolution and ResponseResolution and Response

Barry SpurlockBarry Spurlock

The University of Texas at ArlingtonThe University of Texas at Arlington

April 8, 2004April 8, 2004

Page 2: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 2

OUTLINEOUTLINE• Motivation

• DPCC and How We Used It

• Data

• Analyses & Results

• Conclusions

Page 3: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 3

MotivationMotivation• Dijet study of QCD background (P13)• ICD-MG Task Force (ICD weighting factor)• Initial analyses performed

• 150k JT95TT events

• More data• fixed & corrected• Needed more processing power

• DPCC

Page 4: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 4

DPCCDPCCDistributed & Parallel Computing ClusterDistributed & Parallel Computing Cluster

• Joint effort including UTA CSE dept., UTA HEP dept., and UT Southwest Medical Center (Dallas)

• 97 machines/193 processors• Pentium 4 Xeons at 2.4-2.6 GHz• Over 72 terabytes disk space• The DPCC is supported, in part, by the

NSF grant EIA-0216500

Page 5: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 5

General ProceedureGeneral Proceedure• “Submit_to_PBS”

• Assign job names • Submits “run_in_batch”

• “run_in_batch”• Copy data files, root macro, & tarfile

• File list & root macro are chosen using the job name

• Tarfile includes C++ program, header, MakeClasses

• Runs the root macro as a ROOT batch job

• Root macro makes classes, chains the data files, assigns values to global variables, & runs code

• Compilation problems

Page 6: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 6

Data & Data ProcessingData & Data Processing• Started with thumbnails from QCD group skim of P13

jet data• 200GB, 1281 files, 9.7M events

• tmbfixer & d0correct– Used d0tools to run– Took time to find right version of tmbfixer– d0correct compiled locally

• Skimmed out JT45TT, JT65TT & JT95TT• Skimmed out events with exactly two ‘good’ JCCB

jets, back-to-back (±10°)• 0.5<emf<.95, chf<0.4, hot<10.0, n90>1.0• Events: 170k JT45TT, 160k JT65TT, 37k JT95TT

Page 7: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 7

AnalysesAnalyses

• ICD resolution versus ICD weighting factor

• Dijet asymmetry and response by eta for various ICD weighting factors

• Least squares best fit

Page 8: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 8

ICD ResolutionICD Resolution

• CC-ICD and CC-MG events used

• Cut on narrow ET band of CC jet

• Sigma/E½ used as the resolution of probe

• Resolution plotted against ICD factor for 6 ET bins (60, 75, 85, 100, 120, 150)

Resolution vs. ICD Weighting FactorCC-ICD Events at 120 GeV from JT95TT Data

2.22

2.24

2.26

2.28

2.3

2.32

2.34

2.36

2.38

2.4

2.42

0 1 2 3 4 5 6

ICD Weighting Factor

Res

olu

tio

n

Max Control Eta 0.8 (2500 ev)

Max Control Eta 0.5 (1700 ev)

Parabolic Fit (Eta 0.8) Min at 3.04

Parabolic Fit (Eta 0.5) Min at 3.06

Page 9: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 9

Dijet Asymmetry & ResponseDijet Asymmetry & Response

• CC “control” jet in narrow ET range• Other jet used as probe• Plotted asymmetry and response by eta bin• Plots made for 6 ET bands (60, 75, 85, 100,

120, 150) and various values of ICD weighting factor • 1.0, 1.5, 2.0, 2.4, 2.8, 3.0, 3.2, 3.4, 3.6, 3.8, 4.0,

4.2, 4.4, & 5.0

Page 10: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 10

JT65TT/100 GeV/Factor 1.0JT65TT/100 GeV/Factor 1.0

Page 11: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 11

JT65TT/100 GeV/Factor 1.5JT65TT/100 GeV/Factor 1.5

Page 12: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 12

JT65TT/100 GeV/Factor 2.0JT65TT/100 GeV/Factor 2.0

Page 13: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 13

JT65TT/100 GeV/Factor 2.4JT65TT/100 GeV/Factor 2.4

Page 14: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 14

JT65TT/100 GeV/Factor 2.8JT65TT/100 GeV/Factor 2.8

Page 15: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 15

JT65TT/100 GeV/Factor 3.0JT65TT/100 GeV/Factor 3.0

Page 16: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 16

JT65TT/100 GeV/Factor 3.2JT65TT/100 GeV/Factor 3.2

Page 17: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 17

JT65TT/100 GeV/Factor 3.4JT65TT/100 GeV/Factor 3.4

Page 18: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 18

JT65TT/100 GeV/Factor 3.6JT65TT/100 GeV/Factor 3.6

Page 19: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 19

JT65TT/100 GeV/Factor 3.8JT65TT/100 GeV/Factor 3.8

Page 20: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 20

JT65TT/100 GeV/Factor 4.0JT65TT/100 GeV/Factor 4.0

Page 21: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 21

JT65TT/100 GeV/Factor 4.2JT65TT/100 GeV/Factor 4.2

Page 22: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 22

JT65TT/100 GeV/Factor 4.4JT65TT/100 GeV/Factor 4.4

Page 23: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 23

JT65TT/100 GeV/Factor 5.0JT65TT/100 GeV/Factor 5.0

Page 24: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 24

Best Fit (Least Squares)Best Fit (Least Squares)• ET from probe jet is broken into parts

ETicd = icdf *ET ETccmg = ccmg*ET

ETch = chf*ET ETecmg = ecmg*ET

ETrem = ET – ETicd - ETccmg - ETecmg – Etch

• A linear combination of these is set equal to the ET of the control jet.

• A least squares fit is used to calculate the values of the factors for each part

• This was performed over a variety of eta ranges and ET bands.

• This was also performed where some of the coefficients were fixed to 1

Page 25: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 25

Example of Least Squares FitExample of Least Squares Fit

Page 26: Dijet Analyses for ICD Resolution and Response

April 8, 2004 Barry Spurlock 26

Results/ConclusionsResults/Conclusions

• Submitting 133 jobs at 3 hours each and having it done the next day is very nice!

• …But getting all the results in such a short time is a bit overwhelming.

• The results will be discussed at the ICD-MG task force meeting tomorrow

• At a quick glance, 3.8 seems about right.