LED Approach Flash Lighting System Dimensions URL: http:www.nelt.co.jp/ TEL : +81-(0)3-6746-1770 E-mail : [email protected] Lighting Unit : FX-AVC-01 FX-AVC-01 LED flashing supports safe landing of aircrafts Lighting quality equivalent to Xenon (Dimmable) 20 years Maintenance free design Significant Energy Saving Controller Unit : FX-C-3 Power Unit : FX-AVC-02 Ø62 Ø70 149 228 3-M8 413 287 Ø286 53 261 45 Lighting Unit FX-AVC-02 Power Unit FX-C-3 Controller Unit Front Front Front Top Back Side Side Side 300 3496 600 800 600 100 700 650 50 530 328 413 20

Upload: others

Post on 14-Jul-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Dimensions LED Approach Flash Lighting SystemNEC Approach Flash Lighting System Remarks Descriptions Lighting Unit Power Unit Controller Unit Dimensions (mm) 287 x 228 x 413 530 x

LED Approach Flash Lighting SystemDimensions

URL: http:www.nelt.co.jp/

TEL : +81-(0)3-6746-1770E-mail : [email protected]

Lighting Unit : FX-AVC-01

FX-AVC-01

LED flashing supports safe landing of aircraftsLighting quality equivalent

to Xenon (Dimmable)20 years

Maintenance free designSignificant Energy Saving

Controller Unit : FX-C-3

Power Unit : FX-AVC-02

Ø62

Ø70

149

228

3-M8

413

287

Ø286

53

261

45

■ Lighting Unit

FX-AVC-02■ Power Unit

FX-C-3■ Controller Unit

Front

Front

Front

Top

Back Side

Side

Side

300

(349)

6600

800

600

100

700650

50530 328

413

20

Page 2: Dimensions LED Approach Flash Lighting SystemNEC Approach Flash Lighting System Remarks Descriptions Lighting Unit Power Unit Controller Unit Dimensions (mm) 287 x 228 x 413 530 x

2A,2ms

2ms

Constant current plus emitting

Xenon 500VA Xenon Lump 500H

LED 107VA LED Module 40,000H

20 years maintenance free

■ Energy Saving (Power Consumption) ■ Less Maintenance (Life Time)

Heater ElectrodesHeater Electrodes

■ Front panel heating test data

■Center of Front Panel ………………………… 25±5K■Maximum Temp ………………………………… 40K■Time to reach 80% of Maximum Temp …… 7 minutes

Benefits Approach Flash Lighting System Applications

Brief Technical DataNEC Approach Flash Lighting System Remarks

Descriptions Lighting Unit Power Unit Controller UnitDimensions (mm) 287 x 228 x 413 530 x 328 x 413 600 x 300 x 800Weight (kg) 5.6 30 58.6Timing Signal Voltage AC100V・pulse 30mS to 40mSMonitor Signal 1KΩ Normal Condition = ∞Flash Frequency 120/minutesLight Output High 6,000cd - 20,000cd +10%

Middle 600cd - 2,000cd +10%Low 100cd - 450cd +10%

Power Consumption Heater Off High: 70.0W Middle: 22.0W Low: 18.0WHigh: 107.0VA Middle: 31.0VA Low: 24.0VA

Heater On High: 87.0W Middle: 38.0W Low: 34.0WHigh: 127.0VA Middle: 56.0VA Low: 50.0VA

Heater Power Consumption 10WAdjustable Vertical Angle 0°to 30°Operating Temperature -40℃ to 55℃IP Rating IP66Material Aluminum and Stainless SteelCompliances ICAO Annex 14 vol. 1

JCAB Lighting Spec # 356FAA L-849E/EB-67D ( Apprication process underway)

Center value of Beam

Frigid Environment Field Test @ Shin-Chitose Airport in Hokkaido

① SFL (Sequenced Flashing Lights)

③ AGL (Approach Guidance Lights)

④ RAI (Runway Alignment Indicators)

② REIL (Runway End Identifier Lights)  RWYTIL (Runway Threshold Identification Lights)

Ingress Protection Field Test @Naha Airport in Okinawa

High output Flip-chip LEDLED Module

700lm×1,184 pieces≒830,000 lumens

High density mounting

2A

2.1mm□LED

Achieved Lighting Quality equivalent to that of conventional Xenon lump

Significant Enaergy Saving and 20 years maintenance free design

Safety operation by Laminated Heater (Optional)

LED module decreases 80% of power consumption and increases significant life time compared withXenon lump*

Secure safety operation in a frigid environment

Other Key Features・Lighting-up time adjustment function for the reduction of the load on boot-up.・Luminance back-up function in case of LED circuit failures by the adjustments of flashing time. (* Middle and Low mode only. Up to 7/16(total) LED circuit failures.)・Self diagnosis function for each Lighting Unit.

Prevents the front panel from freezingby the laminated heating technology

*Conditions:Operating hour=5H/day, No heater operation, Life time:Xenon=500H. LED=40,000H