Operating Instructions Vodes UD 500-1500 with acid flushing

dinodos DDE

Installation and OperatingInstructions

n

Diaphragm dosage pump

2015-012-63 /1012/e

Operating InstructionsGeneral

2www.dinotec.de

Notes:

dinotec GmbH.Water and Pool TechnologySpessartstr.763477 Maintal/GermanyTel.: +49 6109-6011-0Fax: +49 6109-6011-90E-mail: [email protected]: www.dinotec.de

Subject to technical changes. Errors excepted.Author: B. Dötsch

Date: 2013-01-22

Operating InstructionsGeneral

3www.dinotec.de

Content

1 General 4

1.1 Declaration of Conformity 4

1.2 General 5

1.3 Notes in bold 5

1.4 Warranty 5

1.5 Qualification and training of personnel 6

1.6 Safety of the system in case of failure of the dosage pump 6

1.7 Dosing of chemicals 7

2 General description 8

2.1 Intended use(s) 8

2.2 Improper operating methods 8

2.3 Device overview 9

3 Technical data 10

3.1 Dimensions 12

4 Assembly and installation 13

4.1 Pump assembly 13

4.2 Hydraulic connection 14

4.3 Electrical connection 15

5 Commissioning 17

5.1 General information 17

5.2 Checks to be carried our before commissioning 17

5.3 Starting and deaerating the pump 17

6 Operation 18

6.1 Operating elements 18

6.2 Operating modes 19

6.3 Signal inputs 20

7 Service 21

7.1 Service intervals 21

7.2 Perform service 21

7.3 Repair 23

8 Spares 23

9 Error 24

9.1 Signalling of faults 24

9.2 List of errors/faults 25

10 Disposal 26

Operating InstructionsGeneral

4www.dinotec.de

1 General

1.1 Declaration of Conformity

We, dinotec GmbH, declare under our sole responsibility that the product dinodos DDE, towhich this declaration relates, is in conformity with the following Council Directives on theapproximation of the laws of the EU Member States:- Machine directive (2006/42/EC)Used standards: EN 809: 1998, EN ISO 12100-1+A1: 2009, EN ISO 12100-2+A1: 2009.- Low voltage directive (2006/95/EC)*Used standard: EN 60204-1+A1: 2009- EMC Directive (2004/108/EC)Used standards: EN 61000-6-2: 2005, EN 61000-6-4: 2007.

Only for products with operating voltages > 50 V AC or > 75 V DC.

Maintal, November 12th, 2012

Ralph ZieglerManaging Director

dinotec GmbHWater and Pool Technology

Spessartstr.763477 Maintal/Germany

Tel.: +49 6109-6011-0Fax: +49 6109-6011-90E-mail: [email protected]: www.dinotec.de

The undersigned person is responsible for the compilation of the technical documentationand authorized to sign the Declaration of CE conformity.

Operating InstructionsGeneral

5www.dinotec.de

1.2 General

These installation and operating instructions contain general instructions that must beobserved during installation, commissioning, operation, monitoring, maintenance anddecommissioning of the pump. It must therefore be read by the installation engineer and therelevant qualified operator prior to installation and start-up, and must be available at theinstallation location at all times.

The operating instructions on hand do not take location-specific regulations into account. Theresponsibility for observance of these regulations lies with the operator, also in respect of theassembly personnel that is assigned!In case that you should require additional information or details, for example in the event ofdamage, please contact the service department of dinotec GmbH.

This manual contains all instructions for the installation, commissioning, maintenance andrepair of the dinodos DEE pump.The safety instructions and notes in bold type are to be observed at all times!

Non-observance of the safety instructions can have dangerous consequences for personnel,the environment and the pump, and will result in a loss of any claims for damages.Failure to comply with the instructions may result in the following hazards:

- Personal injury from exposure to electrical, mechanical and chemical influences.- Damage to the environment and personal injury from leakage of harmful

substances.

1.3 Notes in bold

In this technical information, the bold headings Caution, Warning and Note have the followingmeaning:

Caution:This heading is used if failure to observe the operating or working instructions orprescribed procedures, or incorrect observation of such instructions and the like canlead to accident or personal injury.

Warning:This heading is used if failure to observe the operating or working instructions orprescribed procedures, or incorrect observation of such instructions and the like canlead to damage to the equipment.

Note:This heading is used to draw special attention to important points.

1.4 Warranty

The manufacturer guarantees the operational safety and reliability of the system only if thefollowing conditions are observed:

- Installation, connection, adjustment, maintenance and repairs are carried out only byauthorised and qualified specialist personnel.

- The pump is not dismantled or handled improperly.- Only original spare parts are used for repairs. The use of other parts results in an

exclusion of liability for any resulting damage.- The pump is used in accordance with the instructions in this manual.

Warning:

Operating InstructionsGeneral

6www.dinotec.de

Inappropriate handling and use of acids and lye (storage, refilling, use/application,etc.) in the vicinity of the system invalidates any guarantee or warranty claim.

Safety InstructionsThe safety instructions described in these instructions, existing national regulations on healthprotection, environmental protection and for accident prevention and any internal working,operating and safety regulations of the operator must be observed.Information that is indicated on the pump itself must be observed.Leakages of dangerous substances must be discharged in such a way that they are notharmful for people and the environment.Damage caused by electrical energy must be prevented, see the regulations of the localelectricity supply company.

In order to maintain the safe working condition of the pump and ensure a safe operation, theuser must follow the instructions and warnings contained in this technical manual. If it mustbe assumed that a safe operation is no longer possible, the device must be turned off andtaken out of service, and made safe against accidental operation.

This is the case:

- if the pump shows visible evidence of damage,- if the pump is apparently no longer in working order,- after longer periods of storage under unfavourable conditions.

Warning:Before working on the pump, the pump must be disconnected from the mains. Thesystem must be free of pressure!

1.5 Qualification and training of personnel

The personnel responsible for installation, operation and service must be appropriatelyqualified for these tasks. Roles, responsibilities and supervision of the personnel must beclearly defined by the operator. If necessary, the staff must be appropriately trained.

1.6 Safety of the system in case of failure of the dosage pump

Dosage pump design to the latest technical knowledge. Careful manufacturing process. Allpumps are tested.If the pump should fail nevertheless, the security of the entire system must be ensured. Usethe appropriate monitoring and control functions for this purpose.

Warning:Ensure that chemicals escaping/leaking from the pump or from damaged pipes cannotcause damage to system components and buildings.It is recommended to install leakage monitors and drip pans.

Operating InstructionsGeneral

7www.dinotec.de

1.7 Dosing of chemicals

Caution:Before switching the supply voltage on, the dosing lines must be connected in such away, so that the chemicals present in the dosing head will not splash out and putpeople at risk.The dosing medium is under pressure and can cause damage to the health and theenvironment.

Caution:When working with chemicals, the applicable regulations at the place of use are to beapplied (e.g. wearing protective clothing).Observe the safety data sheets and safety regulations of the chemicals manufacturerwhen working with chemicals.

Caution:If the diaphragm leaks or is broken, dosing liquid will escape from the dischargeopening on the dosing head.Take suitable precautions to prevent harm to health and damage to property causedby escaping dosing liquid!Check daily whether liquid is escaping from the discharge opening! Replacement ofthe diaphragm, see chapter 7 - Service.

Warning:A deaeration hose must be connected to the deaeration screw, which is led to areceptacle, such as a drip pan.

Warning:The dosing medium must be in the liquid aggregate state!Observe the freezing and boiling points of the dosing medium!

Warning:The resistance of parts, such as dosing head, ball valve, seals and pipes, which comeinto contact with the dosing medium is dependent on the medium, media temperatureand operating pressure.Make sure that the parts that come in contact with the dosing medium are resistent tothe dosing medium under operating conditions, see data specifications!For questions regarding the resistance of materials and suitability of the pump forspecific dosing media, please contact dinotec.

Operating InstructionsGeneral description

8www.dinotec.de

2 General description

The dinodos DDE dosage pump is a self-priming diaphragm pump. It consists of a housingwith a stepper motor and electronics, as well as a dosing head with diaphragm and valves.

Excellent dosing features of the pump:- Optimal suction performance (even with degassing media), because the pump is

always working with full suction stroke volume.- Continuous dosing, since the medium is drawn in with a short suction stroke,

regardless of the current dosing flow, and dosed with the longest possible dosingstroke.

2.1 Intended use(s)

The pump is suitable for liquid, non-abrasive, non-combustible and non-flammable liquids inaccordance with the instructions in these installation and operating instructions.

Application areas:- Drinking water treatment- Wastewater treatment- Swimming pool water treatment- Boiler water treatment- CIP (Clean -In-Place)- Cooling water treatment- Process water treatment- Washing plants/installations- Chemical industry- Ultrafiltration processes and reverse osmosis- Irrigation- Paper and pulp industry- Food and beverage industries

2.2 Improper operating methods

The operational safety of the pump is only guaranteed if it is used in accordance with section1.4.

Warning:Frequent disengagement from the mains voltage, e.g. via a relay, can result in damageto the pump electronics and to the breakdown of the pump. The dosing accuracy isalso reduced as a result of internal start-ip processes.Do not use the mains voltage for control of the pump for dosing purposes. Only usethe ’External stop’ function to start and stop the pump!

Caution:Other types of applications or operation of pumps under ambient and operatingconditions that are not allowed are considered to be improper and are not permitted.dinotec cannot be held liable for any damage resulting from incorrect use.

Caution:The pump is NOT approved for operation in potentially explosive areas!

Caution:A sunscreen is required for outdoor installation!

Operating InstructionsGeneral description

2.3 Device overview

Valvepressureside

Control panel (chapter 6.1)

Deaeration valve(chapter 5.3)

Adjustmentknob

Dosinghead

Keys andstatus LEDs

Connectiondeaeration hose

Mechanicallock

Mainsconnection

Dor

Signal inputs(chapter 4.3)

DDE

rain hole in casef diaphragm

9www.dinotec.de

apture

Mounting plate

Valve suction side

Operating InstructionsTechnical data

10

3 Technical data

Mechanical data

Pump type

DDE 6-10

Pump type

DDE 15-4

Setting range [1:X] 1000 1000

Max. dosing flow [l/h] 6.0 15.0

Min. dosing flow [l/h] 0.006 0.015

Max. operating pressure [bar] 10 4

Max. stroke frequency [strokes/min] 140 180

Pump stroke volume [ml] 0.81 1.58

Repeat accuracy [%] ±5

Max. suction lift during operation1 [m] 6

Max. suction lift when priming with wet valves1 [m] 2 3

Min. pressure difference between the suction andpressure side [bar]

1

Max. pressure suction side [bar] 2

Max. viscosity with spring-loaded valves 2 [mPas] 600 500

Max. viscosity without spring-loaded valves 2 [mPas] 50

Min. hose/pipe diameter suction and pressure side[mm] 1,3 4 6

Min. hose/pipe diameter suction side for highly viscousmedia (HV)3 [mm]

9

Min. hose/pipe diameter pressure side for highlyviscous media (HV)3 [mm]

9

Max. media temperature [°C] 45

Min. media temperature [°C] -10

Max. ambient temperature [°C] 45

Min. ambient tem

Max. storage tem

Min. storage tem

Max. noise level

1 Data based on

2 Max. suction lif

3 Length of suctio

1

www.dinotec.de

perature [°C] 0

perature [°C] 70

perature [°C] -20

[dB(A)]l 60

measurements with water

t: 1 m, dosing flow reduced (about 30%)

n line: 1.5 m / Length pressure line: 10 m (with max. viscosity)

Operating InstructionsTechnical data

11www.dinotec.de

Electrical data

Pump type

DDE 6-10

Pump type

DDE 15-4

Voltage [V] 100-240 V, 50-60 Hz

Length connection cable [m] 1.5

Max. current consumption (100 V) [A] 8

Max. current consumption (230 V) [A] 25

Max. power consumption P1 [W] 12

Protection class casing IP 65, Nema 4X

Electrical protection class II

Signal inputs

Pump type

DDE 6-10

Pump type

DDE 15-4

Max. load empty warning input 12 V, 5 mA

Max. load pulse input 12 V, 5 mA

Max. load external stop input 12 V, 5 mA

Min. pulse length [ms] 5

Max. pulse frequency [Hz] 100

Max. line resistance empty warning [Ω] 1000

Max. line resistance in pulse circuit [Ω] 1000

Weight / Size

Pump type

DDE 6-10

Pump type

DDE 15-4

Weight (PVC, PP, PVDF) [kg] 2.4

Weight (stainless steel) [kg] 3.2

Diaphragm diameter [mm] 44 50

Operating InstructionsTechnical data

12www.dinotec.de

3.1 Dimensions

Pump type A1 (mm] B (mm] C (mm] D (mm]

DDE 6-10 251 196 46.5 24

DDE 15-4 251 200.5 39.5 24

DDE

Operating InstructionsAssembly and installation

13www.dinotec.de

4 Assembly and installation

4.1 Pump assembly

The pump is delivered with a mounting plate. The mounting plate can be mounted vertically,e.g. on a wall, or horizontally, e.g. as on a tank. It takes only a few quick steps to firmlysecure the pump to the mounting plate by means of a slot mechanism.The pump can easily be released from the mounting plate for maintenance.

4.1.1 Requirements

- The mounting surface must be stable and must not vibrate.- The direction of dosing should be vertically from bottom to top.

4.1.2 Align the mounting plate and install it.

- Vertical installation: The mounting plate slot mechanism must be on top.- Horizontal installation: The mounting plate slot mechanism must be opposite the

dosing head.- The mounting plate can be used as a drilling template; for drill hole distances, see

above figure.

Attaching the mounting plate

CautionTake care that no cables or lines are damaged during installation!

1. Mark the drilling holes.2. Drill the holes.3. Secure the mounting plate with four screws (5 mm diameter), to the wall, on the

mounting bracket, or on the tank.

4.1.3 Engage pump in mounting plate

Attach the pump to the mounting plate support clamps and slide under slight pressureuntil it engages.

Operating InstructionsAssembly and installation

14www.dinotec.de

4.2 Hydraulic connection

Caution:Danger of chemical burns!Wear protective clothing (gloves and safety glasses) while working on dosing head,on connectors or cables!

Warning:The dosing head may contain water from the factory inspection. When dosing mediawhich should not come into contact with water, another medium must be dosedbeforehand!

Warning:A proper function can only be guaranteed when lines supplied by dinotec are used.The used lines must correspond to the pressure limits specified in chapter 3"Technical data".

Important details regarding the installation- Observe suction lift and cable diameter, see chapter 3 "Technical data".- Shorten the hoses at right angles.- Ensure that there are no loops or kinks in the hoses.- Keep the suction lines as short as possible.- Route suction line up towards the suction valve.- Installing a filter in the suction line protects the entire installation from dirt, thus

reducing the risk of leakage.

How to connect the hose1. Slide the union nut and tensioning ring on the hose.2. Insert the cone part completely into the tube (slide in).3. Push union nut and tensioning ring across hose.4. Tighten the union nut by hand.

– Do not use any tools!– When PTFE is used as sealing material, re-tighten the union nut after 2-5

hours of operation!5. Attach the deaeration hose to the corresponding connection and lead it into a

receptacle, such as a drip pan.

Note:The pressure differential between the suction and pressure side must be at least 1bar!

Warning:Re-tighten the dosing head screws with 3 Nm before commissioning and after 2 - 5hours of operation.

Cone partTensioning ring

Union nut

Hose

O

ITc

4

C

CTc

CTm

TSC

perating InstructionsAssembly and installation

15www.dinotec.de

nstallation example:he pump offers various installation options. In the example below, the pump is installed inonjunction with a suction lance, level switch and multifunction valve.

.3 Electrical connection

onnection to the mains

aution:he enclosure class/protection class (IP65) is only guaranteed if plugs or protectiveaps are correctly installed!

aution:he pump can start automatically when the mains voltage is switched on! Do notanipulate mains plug or cable!

he pump is supplied with assembled mains cable and plug.et capacity adjustment knob to 0 % (see chapter 6.1 "Operating elements").onnect the mains plug with the mains socket.

Multi-functionvalveDeaeration

hose

Container

Suction lance withempty warning

Operating InstructionsAssembly and installation

16www.dinotec.de

Signal inputs

External stop and pulse input

Function Pins Type ofconnection

1/brown 2/white 3/blue 4/black

External stop GND X Pulse

Pulse GND X Pulse

Level signal: empty warning

Function Pins Type ofconnection

1/brown 2/white 3/blue 4/black

Emptywarning

X GND Pulse

Note:Use force to push the connectors for signal inputs onto the connection sockets as faras they will go. Otherwise, there is no contact. The union nut cannot push theconnector all the way (as far as it will go) into a contact position.

Operating InstructionsCommissioning

17www.dinotec.de

5 Commissioning

5.1 General information

Caution:Suction and discharge lines must be connected correctly.The deaeration line must be properly connected and inserted into a suitable tank.

Warning:Re-tighten the dosing head screws with 3 Nm before commissioning and after 2 - 5hours of operation.

5.2 Checks to be carried our before commissioning

– Check that the rated voltage indicated on the nameplate complies with the localconditions.

– Check that all connections are assembled correctly. Re-tighten connections, ifnecessary.

– Check that the dosing head screws are tightened with the specified torque (3 Nm), re-tighten if necessary.

– Check that all electrical cables and plugs are connected correctly.

5.3 Starting and deaerating the pump

– Connect the mains cable.– Open the deaeration screw about half a turn.– Press the deaeration key (100 %) and hold it down, until liquid flows out of the

deaeration hose continuously and without any bubbles.– Close the deaeration screw.

The pump is deaerated.

Operating InstructionsOperation

18www.dinotec.de

Status LED "Pulse"

Operating mode button

Mechanical lock

Status LED"Manual"

6 Operation

6.1 Operating elements

Adjustment knobUse the capacity adjustment knob to set the dosing capacity in percent of the maximumdosing flow of the pump. Due to the logarithmical increase of the percent values, even smalldosing capacities can be set accurately.

Mechanical lockThe mechanical lock protects the set dosing capacity against unauthorised manipulation. Forlocking, tighten the screw until the adjustment knob cannot be turned anymore.

Keys and LEDsWhen pressing and holding down the deaeration key, the pump doses at 100 % for a certaintime. The deaeration key can be used e.g. for deaeration.The operation mode switch is used to change between the ’Manual’ and ’Pulse’ modes (seechapter.6.2 "Operating modes"). Depending on the current mode, the respective status LEDis active ("Pulse" = upper LED; "Manual" = lower LED).The status LEDs indicate the following operating states and faults:

LED colour Operating state/Error

Green (flashing) Stop

Green Running

Yellow Standby (external stop)

Red Empty warning (alarm)

Red (flashing) Motor blocked

Logarithmicscale

Capacity adjustmentknob

Deaeration button

DDE

Operating InstructionsOperation

19www.dinotec.de

6.2 Operating modes

The following operating modes are available:

Manual, see chapter 6.2.1

Pulse, see chapter 6.2.2)

6.2.1 Manual

In this operation mode, the pump doses constantly the dosing quantity set by the adjustmentknob.

The setting range is dependent on the pump type:

Type Setting range [l/h]

DDE 6-10 0.0060 – 6

DDE 15-4 0.0150 - 15

6.2.2 Pulse

In this operating mode, the pump adds the set dosing quantity for each incoming (potential-free) pulse, e.g. from a water meter. There is no direct connection between incoming pulsesand dosing strokes. The pump automatically calculates the optimum stroke frequency fordosing the set volume per pulse.

The calculation is based on:- the frequency of external pulses- the set stroke volume in percent

The dosing quantity per pulse is set to a value between 0.1% and 100% of the stroke volumeusing the adjustment knob.

The setting range is dependent on the pump type:

Type Setting range [ml/pulse]

DDE 6-10 0.0008 - 0.81

DDE 15-4 0.0016 - 1.58

The frequency of the incoming pulses is multiplied by the set dosing quantity. If the pumpreceives more pulses than it can process at the maximum dosing flow, it runs at themaximum stroke frequency in continuous operation. Excess pulses will be ignored.

Note:To achieve the maximum dosing capacity, we recommend the following setting fordinotec measurement and control devices (also dinotecNET ready and AquaTouch), ifthey are set to pulse frequency:

Type Frequency (pulses/h) atcontrol unit

DDE 6-10 7200

DDE 15-4 9600

Please observe our operating instructions for your measuring and control device.

Operating InstructionsOperation

20www.dinotec.de

6.2.3 Changing the operating mode

1. Set the adjustment knob to 0 %.2. Connect the mains supply (see chapter 4.3 Electrical connection).3. Press the operating mode button and hold for at least for 5 seconds.

The new operating mode is saved.

6.3 Signal inputs

Note:Use force to push the connectors for signal inputs onto the connection sockets as faras they will go. Otherwise, there is no contact. The union nut cannot push theconnector all the way (as far as it will go) into a contact position.

6.3.1 External stop

The pump can be stopped via an external pulse, e.g. from a control center. When activatingthe external stop pulse, the pump switches from the operating condition "Running" to the"Standby" mode. The respective status LED lights yellow according to the selected mode.

Warning:Frequent disengagement from the mains voltage, e.g. via a relay, can result in damageto the pump electronics and to the breakdown of the pump. The dosing accuracy isalso reduced as a result of internal start-ip processes.Do not use the mains voltage for control of the pump for dosing purposes. To startand stop the pump, use only the "External stop" function!

6.3.2 Empty warning

To monitor the level in the tank, a one-level signal measurement (empty warning) can beconnected to the pump.The pump responds to the signal in the following ways:

- Active Status LED lights red- Pump stops

Warning:When the tank is filled up again, the pump restarts automatically!

6.3.3 Changing the contact type

The signal inputs (empty warning and external stop) are configured at the factory as normallyopen contact (NO). They can be reconfigured as normally closed contact (NC). Thereconfiguration is always made for both inputs.

1. Set the adjustment knob to 0 %.2. Connect the mains supply3. (see chapter 4.3 Electrical connection).4. Press the deaeration button and the operation mode button simultaneously and hold

for at least 2 seconds,

The new contact type is saved.

Operating InstructionsService

21www.dinotec.de

7 Service

In order to ensure a long service life and a proper dosing accuracy, wearing parts such asdiaphragms and valves must be regularly checked for signs of wear. Where necessary,replace worn parts with original spare parts made from suitable materials.Should you have any questions, please contact your service partner.

7.1 Service intervals

Caution:If the diaphragm leaks or is broken, dosing liquid will escape from the dischargeopening on the dosing head.Take suitable precautions to prevent harm to health and damage to property causedby escaping dosing liquid!Check daily whether liquid is escaping from the discharge opening!

Interval Activity

Daily Check, if liquid leaks from dosing head, drain opening or valves. Ifnecessary, tighten dosing head screws (3 Nm), valves and unionnuts, or perform service

(see 7.2 Perform service).

2 years or 8000operating hours

Replace diaphragms and valves

(see 7.2 Perform service)

7.2 Perform service

Only spare parts and accessories from dinotec should be used for maintenance. The usageof non-original spare parts and accessories renders any liability for resulting damages nulland void.

Caution:Danger of chemical burns!Wear protective clothing (gloves and safety glasses) while working on dosing head,on connectors or cables!Do not allow any chemicals to leak from the pump. Collect and dispose of allchemicals correctly!

Warning:Before working on the pump, the pump must be disconnected from the mains. Thesystem must be free of pressure!

Operating InstructionsService

22www.dinotec.de

Figure pump head:

1 Safety diaphragm2 Flange3 O-ring4 Diaphragm5 Valve on pressure side6 Valve on suction side7 Dosing head8 Screws with washers9 Cover10 Deaeration screw

7.2.1 Dismantling the diaphragm and valves

1. Make the system pressureless.2. Empty the dosing head before maintenance and flush it, if necessary.3. Set the adjustment knob to 0 %.4. Switch off mains supply.5. Take suitable steps to ensure that the returning liquid is safely collected.6. Dismantle suction, pressure and deaeration hoses.7. Dismantle valves on suction and discharge side (5, 6).8. Remove the cover (9).9. Loosen the screws (8) on the dosing head (7) and remove the screws and discs.10. Remove the dosing head (7).11. Unscrew diaphragm (4) counter-clockwise and remove with flange (2).

7.2.2 Reassembling the diaphragm and valves

1. Attach the flange (2) correctly and screw on the new diaphragm (4) clockwise.- Make sure that the O-ring (3) is seated correctly!

2. Connect / switch on mains supply.3. Turn the adjustment knob slowly to bring the diaphragm into its service position

’inside’ (end of suction phase, diaphragm retracted). Set the adjustment knobback to 0 %.

4. Switch the mains supply off again.5. Attach the dosing head (7).6. Install screws with discs (8) and cross-tighten.

– Torque: 3 Nm.7. Attach the cover (9).8. Install new valves (5, 6).

– Do not interchange valves and pay attention to direction of arrow.

Operating InstructionsSpares

23www.dinotec.de

9. Connect suction, pressure and deaeration hoses (see section 4.2 Hydraulicconnection)

10. Ventilate dosing pump (see section 5.3 Start and vent the pump).11. Please observe the notes on commissioning in chapter 5 "Commissioning“.

7.3 Repair

Caution:The pump housing must only be opened by personnel authorised by dinotec.Repairs must only be carried out by authorised and qualified personnel.Switch off the pump and disconnect it from the voltage supply before carrying outmaintenance work and repairs.

8 Spares

Name Order number

Type DDE 6-10 Type DDE 15-4

Diaphragm 0204-450-00 0204-451-00

Suction/pressure valve (PVC version) 0204-440-00 0204-442-00

Suction/pressure valve (version PVDF, chlorine-resistent)

0204-441-00 0204-443-00

Pump head* (PVC version) 0204-420-00 0204-422-00

Pump headFehler! Textmarke nicht definiert. (versionPVDF, chlorine-resistent)

0204-421-00 0204-423-00

Hose connector (PVC version) 0204-179-00 0204-179-01

Deaeration screwwith O-ring

Service kit (PVC version) 0204-403-00 0204-405-00

Service kit (version PVDF, chlorine-resistent)y 0204-404-00 0204-406-00

Frequency cable, connector angled 3054-225-00 3054-225-00

Frequency cable, connector straight 0204-115-00 0204-115-00

Suction lance rigid, adjustable in height, hoselength 1.5 m with M12 connector

0284-104-90 0284-104-91

Suction line flexible, with cover screws, hoselength 1.5 m with M12 connector

0284-104-90 0284-104-91

Mounting plate incl. 4 screws 0204-470-00 0204-470-00

* Dosing head only available as complete kit with diaphragm, suction/pressure valves anddeaeration screw

Operating InstructionsError

24www.dinotec.de

9 Error

9.1 Signalling of faults

Depending on the selected operating mode, the pump will signal the following faults/errorsvia the corresponding status LED:

LED colour Error Remedy

Re-fill tank

Red Empty warning Check type of pulse (seechapter 6.3.3

Reduce the counterpressure

Red (flashing) Motor blockedIf necessary, have the gearrepaired

Operating InstructionsError

25www.dinotec.de

9.2 List of errors/faults

Error Error cause / Remedy Remedy

Install additional spring-loaded valve (approx. 3 bar)on the discharge sideDosing flow too high

Inlet pressure greater thanbackpressure

Increase pressuredifferential

Air in dosing head Deaerate the pump

Diaphragm defectiveReplace diaphragm (see7.2.2)

Leakage/breakage in lines Check the lines and repair

Valves leaking or clogged Check and clean the valves

Check that the arrow on thevalve housing is pointing inthe direction of flow.Valves not correctly installed

Check whether all O-ringshave been correctly installed

Suction line cloggedClean suction line/install astrainer

Reduce the suction liftSuction lift too high

Install a suction aid

Use a hose with a largerdiameter

Viscosity too highInstall a spring-loaded valveon the pressure side

No dosing flow or dosingflow too low

Open the deaeration screw Close the deaeration screw

Valves leaking or cloggedRe-tighten valves, replacevalves if necessary (see7.2.2)Irregular dosing

Counter pressurefluctuations

Keep the counter pressureat a constant level

Liquid leaking from the drainopening on the flange

Diaphragm defectiveReplace diaphragm (see7.2.1)

Dosing head not re-tightened

Re-tighten the screws (see4.2 Connecting thehydraulics)

Liquid leaking

Valves not re-tightenedRe-tighten the valves/unionnuts (see 4.2 Connectingthe hydraulics)

Suction lift too highReduce the suction lift,establish a suction feedoperation

Open the deaeration screwPump not priming

Counter pressure too high Flush the system, replacevalves if necessary (see 7.2)

Pump not running(while in the pulse controloperating mode)

Control cable plug notinserted properly

Insert the plug firmly up tothe stop

Operating InstructionsDisposal

26www.dinotec.de

Error Error cause / Remedy Remedy

Pump does not respond tocontainer empty message

Control cable plug notinserted properly

Insert the plug firmly up tothe stop

Pump does not respond toexternal stop

Control cable plug notinserted properly

Insert the plug firmly up tothe stop

10 Disposal

This product and all its associated parts must be disposed of in an environmentally friendlymanner. Please use the appropriate local waste collection services. If there is no such facilityor the facility refuses to accept the materials used in the product, the product can be sent todinotec.