directional control valve block sbe 2 0

12
Wegeventilblock SBE Directional control valve block SBE Bloc distributeur SBE Mobilhydraulik Mobile Hydraulics Hydraulique mobile Ausgabe Version Version 2.0 5 Elektrisch proportionaler Wegeventilblock für Stapler Electric proportional directional control valve block for forklift trucks Bloc distributeur à commande électrique proportionnelle pour chariots élévateurs

Upload: api-3854910

Post on 07-Jun-2015

488 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Directional Control Valve Block Sbe 2 0

Wegeventilblock SBEDirectional control valve block SBEBloc distributeur SBE

MobilhydraulikMobile HydraulicsHydraulique mobile

AusgabeVersionVersion 2.0

5

Elektrisch proportionaler Wegeventilblock für StaplerElectric proportional directional control valve block for forklift trucksBloc distributeur à commande électrique proportionnelle pour chariots élévateurs

Page 2: Directional Control Valve Block Sbe 2 0

2 Mobile Hydraulics

yModerne Gabelstapler setzen für dieHubhydraulik zunehmend elektrischbetätigte Wegeventile ein.Dies bietet je nach Staplerbauart ent-scheidende ergonomische Vorteileund Freizügigkeit bezüglich des Ventil-Einbauortes.Hierzu wurde der neue Wegeventil-block SBE entwickelt, der für Elektro-Gabelstapler mit Impulssteuerung undDiesel-Gabelstapler bis 3 t eingesetztwerden kann.O Nenndurchfluß Heben/Senken

70 l/minO Nenndurchfluß Neigen/Zusatz

30 l/minO Betriebsdruck max. 250 barO Versorgungsspannung 24 V

Der Einsatz des SBE bietet folgendeVorteile:O LS-Ventil zur Minimierung der

EnergieverlusteO elektrisch proportional betätigt mit

sehr gutem FeinsteuerverhaltenO vorgesteuertes Senkenmodul mit

hoher DichtheitO integrierte Vorspannventile für

NeigezylinderO Wegeventilblock elektrisch

anschlußfertig für 2poligen Kfz-Stecker, d. h. keine nachträglichehydraulisch-elektrische Justierungerforderlich

O einseitige Magnetanordnung zurgünstigen Verlegung des Kabel-baums

yyIncreasingly, modern fork-lift trucksuse electrically operated directionalcontrol valves for the lifting hydraulics.Depending upon the type of fork-lifttruck in question, this offers decisiveadvantages in terms of ergonomics aswell as freedom of choice in the instal-lation location of the valves.To this aim, the new SBE directionalcontrol valve block has been devel-oped, which is suitable for use withelectric fork-lift trucks with pulsecontrol and diesel fork-lift trucks upto 3 tons.O Nominal flow for lifting and lowering

70 l/minO Nominal flow for tilting and auxiliary

functions 30 l/minO Max. operating pressure 250 barO Supply voltage 24 V

Using the SBE offers the followingadvantages:O LS valve for minimizing power

lossesO Electrical proportional control with

very good fine metering character-istics

O Highly leak-proof pilot operatedlowering module

O Integrated pressure sequencevalves for tilting cylinder

O Directional control valve block readyfor connection to 2-pole motor-vehicle connector, i.e. no need forlater adjustment of hydraulics/electrics

O Solenoids positioned on one sidefor the best possible routing of thewiring harness

yyyLes chariots élévateurs modernes utili-sent de plus en plus des distributeursà commande électrique pour lesystème hydraulique de levage.Cela apporte, suivant la constructiondu chariot élévateur, d’importantsavantages ergonomiques et unegrande liberté quant à l’emplacementde montage du distributeur.Le nouveau bloc distributeur SBE, quia été conçu pour cet usage, peut êtreutilisé pour des chariots élévateursélectriques à commande par impul-sions et des chariots élévateurs dieseljusqu’à 3 t.O Débit nominal levage/abaissement

70 l/minO Débit nominal inclinaison/fonctions

complémentaires 30 l/minO Pression de service 250 bar max.O Tension d’alimentation 24 V

L’utilisation du SBE offre les avanta-ges suivants :O Distributeur LS permettant une

réduction des pertes énergétiquesO Commande électrique propor-

tionnelle permettant une précisionexcellente

O Module d’abaissement piloté d’unegrande étanchéité

O Valves de précontrainte intégréespour vérin d’inclinaison

O Bloc distributeur prêt au raccorde-ment électrique pour connecteursautomobiles à 2 pôles, c’est-à-direqu’aucun ajustage hydro-électriqueultérieur n’est nécessaire.

O Disposition unilatérale des électro-aimants permettant une posefavorable du faisceau de câbles

SBE-BlockSBE blockBloc SBE

Page 3: Directional Control Valve Block Sbe 2 0

yWegeventilblock SBE– elektrisch proportional betätigt

1 Anschlußeckventil– 2-Wege-Eingangsdruckwaage mit

Vorsteuer-DBV– Zuschaltventil für LS-Druck– Hebenschieber mit Rückschlag-

ventil– Senkenmodul– 2-Wege-Stromregelventil zur

Senkenstrombegrenzung

2 Wegeventilsegment Neigen– 2-Wege-Stromregelventil im Zulauf– Integrierte Vorspannventile

3 Wegeventilsegment Zusatz– Rückschlagventil im P-Kanal

4 Endeckventil Zusatz– Rückschlagventil im P-Kanal– Verbindung LS-Leitung mit

Rücklauf

yyDirectional control valve block SBE– Electrical proportional control

1 Subplate valve unit– 2-way inlet pressure compensator,

with pilot pressure relief valve– Pressure sequence valve for LS

pressure– Lifting spool with check valve– Lowering module– 2-way flow control valve for limiting

the lowering flow

2 Directional control valvesegment, tilting

– 2-way flow control valve in inlet– Integrated pressure sequence

valves

3 Directional control valvesegment, auxiliary functions

– Check valve in P-duct

4 End-plate valve unit, auxiliaryfunctions

– Check valve in P-duct– Connection LS line with return flow

yyyBloc distributeur SBE– A commande électrique pro-

portionnelle

1 Unité comprenant distributeuret plaque de raccordement

– Balance de pression d’entréeà 2 voies avec limiteur de pressionpilote

Mobile Hydraulics 3

– Valve de séquence pour pressionLS

– Tiroir de levage avec clapet anti-retour

– Module d’abaissement– Valve de réglage du débit à 2 voies

permettant une limitation du débitd’abaissement

2 Elément distributeur inclinaison– Valve de réglage du débit à 2 voies

sur l’alimentation– Valves de précontrainte intégrées

3 Elément distributeur fonctionscomplémentaires

– Clapet anti-retour dans le canal P

4 Unité comprenant distributeuret plaque finale

– Clapet anti-retour dans le canal P– Liaison conduite LS avec retour

Page 4: Directional Control Valve Block Sbe 2 0

4 Mobile Hydraulics

yKenngrößen BasisventilAllgemein Ventilblock bestehend aus:

1 Anschlußeckventil, 1 Endeckventil, 1 Wegeventilsegment-Neigenwahlweise 1 Wegeventilsegment-Zusatz3 Zuganker

Befestigung Gewinde M8 in Anschluß- und EndeckventilLeitungsanschlüsse Einschraubgewinde siehe BestellübersichtEinbaulage Schieberachsen horizontal, andere Lage auf AnfrageHydraulischDruckmittel Hydrauliköl auf Mineralölbasis, andere z. B. umweltschonende

Flüssigkeiten auf AnfrageViskosität 10 ... 400 mm2/sDruckmitteltemperatur –20 °C (kurzzeitig) ... +90 °CFilterung Ölverschmutzung Klasse 8 nach NAS 1638

bzw. Klasse 17/14 nach ISO 4406Zulässiger Höchstdruck Eingang bei P: 250 bar

Ausgang bei R: 15 barAnschlüsse A, B: 280 bar

Leckage A, B R R QL = 7,5 cm3/min bei ∆p = 160 bar in WV-ew, L 10 C Q8-EM 2bei T = 50 °C, ν = 30 mm2/s QL = 12 cm3/min bei ∆p = 110 bar in WV-dw, L 30 G Q2-EM 2

QL = 30 cm3/min bei ∆p = 125 bar in WV-dw, L 30-EM 2, L 30-EM 2 E 1Nenndurchfluß ew = 70 l/min, dw = 30 l/min, siehe auch Kennlinien Seite 8ElektrischMagnete Proportional

ED Heben, Senken: S3 = 60%, ts = 10 minED Neigen, Zusatz: S3 = 40%, ts = 10 minSpezielle Ansteuerelektronik erforderlich

Magnetleistung Pnom 21 WMagnetspannung Unom 24 V (12 V auf Anfrage)Magnetstrom Inom 1,46 ASchutzart IP 65Steckerausführung Jet-Stecker 2-polig

Ventilklasse SBEBestellnummer 0 52815…Ventiltyp 4/3 und 3/3 Wege proportionalAnsteuerungsart elektromagnetisch, direkt, vorgesteuert (Senkenmodul)Hydraulische Stellgröße Volumenstrom QMagnet Anschlußart 2poliger Jet-SteckerSpulenwiderstand (RL) bei 20 °C 9,5 q < RL < 10,2 qRSpule bei Temp. Gehäuse = 80 °C # 16 qMagnet Arbeitshub (s) P 3,5 mmInduktivität bei Nennhub (50 Hz) P 157 mHImax. # 1,46 AStrom-Proportionalbereich:

Heben 0,3 A < Iprop. < 1,46 ASenken 0,4 A < Iprop. < 1,46 Adoppeltwirkend 0,8 A < Iprop. < 1,46 A

Dithersignal 0,4 A ssDitherfrequenz 120 Hz ± 5 HzDitherform des Stromsollwertes Dreiecksignal

Schnittstellenbeschreibung

Page 5: Directional Control Valve Block Sbe 2 0

Mobile Hydraulics 5

yySpecifications Basic valveGeneral Valve block set consisting of:

1 subplate valve unit, 1 end-plate valve unit, 1 DCV segment for tilting1 DCV segment for auxiliary functions, optional3 tie bolts

Mounting M 8 thread in subplate and end-plate valve unitsPressure connections Internal thread, see order detailsInstallation position Spool axes horizontal, other positions on requestHydraulicPressure fluid Mineral oil based hydraulic oil, other fluids, e.g. environmentally

acceptable fluids, on requestViscosity 10 ... 400 mm2/sFluid temperature –20 °C (short-time) ... +90 °CFiltration Oil contamination class 8 to NAS 1638

or class 17/14 to ISO 4406Max. permitted pressure Inlet at P: 250 bar

Outlet at R: 15 barPorts A, B: 280 bar

Leakage A, B R R QL = 7.5 cm3/min at ∆p = 160 bar in DCV single acting, L 10 C Q8-EM 2at T = 50 °C, ν = 30 mm2/s QL = 12 cm3/min at ∆p = 110 bar in DCV double acting, L 30 G Q2-EM 2

QL = 30 cm3/min at ∆p = 125 bar in DCV double acting, L 30-EM 2, L 30-EM 2 E 1Nominal flow single acting = 70 l/min, double acting = 30 l/min,

also see characteristic curves on page 8ElectricalSolenoids Proportional

c.d.f. lifting, lowering: S3 = 60%, ts = 10 minc.d.f. tilting, auxiliary functions: S3 = 40%, ts = 10 minSpecial trigger electronics required

Solenoid power Pnom 21 WSolenoid voltage Unom 24 V (12 V on request)Solenoid current Inom 1.46 ADegree of protection IP 65Plug version Jet plug, 2-pole

Valve class SBEPart number 0 52815…Valve type 4/3 and 3/3-way proportionalType of actuation electromagnetic direct, pilot operated (lowering module)Hydraulic actuating variable Flow rate QSolenoid connection 2-pole Jet plugCoil resistance (Rcoil) at 20 °C 9.5 q < Rcoil < 10.2 qRcoil at housing temp. = 80 °C # 16 qWorking stroke of solenoid (s) P 3.5 mmInductance at nominal stroke (50 Hz) P 157 mHImax. # 1.46 AProportional band of current:

Lifting 0.3 A < Iprop. < 1.46 ALowering 0.4 A < Iprop. < 1.46 Adouple-acting 0.8 A < Iprop. < 1.46 A

Dither signal 0.4 A ssDither frequency 120 Hz ± 5 HzDither form of current setpoint Triangular signal

Description of interface

Page 6: Directional Control Valve Block Sbe 2 0

6 Mobile Hydraulics

yyyCharactéristiques Distributeur de baseGénérales Bloc distributeur comprenant:

1 unité comprenant distributeur et plaque de raccordement,1 unité comprenant distributeur et plaque finale,1 élément distributeur inclinaison,au choix 1 élément distributeur fonctions complémentaires3 tirants d’assemblage

Fixation Filetage M8 dans unité comprenant distributeur et plaque de raccordementet unité comprenant distributeur et plaque finale

Raccordement Filetage, voir gamme des produitsPosition de montage Axes des tiroirs horizontaux, autre position sur demandeHydrauliquesFluide Huile hydraulique minérale, autres fluides, par ex. fluides non polluants,

sur demandeViscosité 10 ... 400 mm2/sTempérature du fluide –20 °C (temporaire) ... +90 °CFiltration Encrassement du fluide: classe 8 selon NAS 1638

ou classe 17/14 selon ISO 4406Pression max. admissible Entrée à P: 250 bar

Sortie à R: 15 barRaccords A, B: 280 bar

Fuites A, B R R QL = 7,5 cm3/min à ∆p = 160 bar, distributeur à simple effet, L 10 C Q8-EM 2à T = 50 °C, ν = 30 mm2/s QL = 12 cm3/min à ∆p = 110 bar, distributeur à double effet, L 30 G Q2-EM 2

QL = 30 cm3/min à ∆p = 125 bar, distributeur à double effet, L 30-EM 2, L 30-EM 2 E 1Débit nominal Simple effet = 70 l/min, double effet = 30 l/min, voir également courbes

caractéristiques page 8ElectriquesElectro-aimants A action proportionnelle

Durée d’enclenchement levage, abaissement: S3 = 60%, ts = 10 minDurée d’enclenchement inclinaison, fonctions complémentaires:S3 = 40%, ts = 10 minElectronique de pilotage spéciale nécessaire

Puissance absorbée Pnom 21 WTension électro-aimant Unom 24 V (12 V sur demande)Courant électro-aimant Inom 1,46 ADegré de protection IP 65Version de connecteur Connecteur Jet à 2 pôles

Série de distributeurs SBERéférence de commande 0 52815…Type de distributeur à 4/3 et 3/3 voies, à effet proportionnelType de pilotage électromagnétique direct, pilotées (module d’abaissement)Grandeur de réglage hydraulique Débit volumique QType de raccordement de l’aimant Connecteur Jet à 2 pôlesRésistance de bobine (Rbobine) à 20 °C 9,5 q < Rbobine < 10,2 qRbobine à la température # 16 qdu corps = 80 °CCourse de travail de l’aimant (s) P 3,5 mmInductivité pour course P 157 mHnominale (50 Hz)Imax. # 1,46 ACourant-plage proportionnelle:

levée 0,3 A < Iprop. < 1,46 Adescente 0,4 A < Iprop. < 1,46 Adouble effet 0,8 A < Iprop. < 1,46 A

Signal Dither 0,4 A ssFréquence Dither 120 Hz ± 5 HzForme Dither de la valeur de consigne Signal triangulairedu courant

Description de l’interface

Page 7: Directional Control Valve Block Sbe 2 0

yBestellübersicht

Die hier aufgeführten Sinnbilder be-ziehen sich auf Standardtypen. Spe-zielle Ventilvarianten und kompletteSteuerblöcke werden im Rahmendes Varianten Baukastens im Dialogmit unserem technischen Verkauffestgelegt und in internen Kennlistendokumentiert.

yyOrder details

The symbols listed here relate tostandard versions. Details for specialvalve variatons and complete controlblocks are specified as part of themodular system in consultation withour technical sales department andrecorded on internal code lists.

yyyGamme des produits

Les symboles de commandementionnés dans cette brochurese réfèrent aux types standard. Lesvariantes spéciales des distributeurset les blocs de commande completsseront définis au sein du systèmemodulaire en collaboration avecnotre service technico-commercialet documentés dans des listes decodification internes.

Mobile Hydraulics 7

Sinnbild Bemerkungen kg «Symbol RemarksSymbole Remarques

A 9/L 10C Q 8-EM 2 Qmax: P M 22 x 1,5 0 521 612 ...P R A, A R R = 70 l/min R M 26 x 1,5

A M 22 x 1,5

P G 1/2R G 3/4A G 1/2

L 30 GH Q 2-EM 2 Qmax: A M 18 x 1,5 0 521 612 ...P R A/B = 30 l/min B

A G 3/8B

L 30-EM 2 Qmax: A M 18 x 1,5 0 521 612 ...P R A/B = 30 l/min B

A G 3/8B

L 30-EM 2 E 1 Qmax: A M 18 x 1,5 0 521 612 ...P R A/B = 30 l/min B

A G 3/8B

Page 8: Directional Control Valve Block Sbe 2 0

yKennlinienν = 30 mm2/s, T = 50 °C

yyCharacteristic curvesν = 30 mm2/s, T = 50 °C

yyyCourbes caractéristiquesν = 30 mm2/s, T = 50 °C

8 Mobile Hydraulics

Durchflußwiderstandbei voll geöffnetemWegeventil

Pressure drop whendirectional control valve iscompletely open

Perte de pression lorsque ledistributeur est entièrementouvert

AnschlußeckventilSubplate valve unitUnité comprenant distributeuret plaque de raccordement

Zusatz-/EndeckventilAuxiliary/end-plate valve unitUnité comprenant distributeuret plaque finale/fonctionscomplémentaires

Neutralumlauf P R ROpen centre pump control P R RCircuit neutre P R R

Page 9: Directional Control Valve Block Sbe 2 0

yVolumenstrom über Magnetstrom

Anschlußeckventil P R ASubplate valve unit P R AUnité comprenant distributeuret plaque de raccordement P R A

Anschlußeckventil A R RSubplate valve unit A R RUnité comprenant distributeuret plaque de raccordement A R R

Zusatz-/Endeckventil P R A, BAuxiliary/end-plate valveunit P R A, BUnité comprenant distributeuret plaque finale/fonctionscomplémentaires P R A, B

yyFlow versus solenoid current

yyyDébit volumique en fonction ducourant de l’électro-aimant

Mobile Hydraulics 9

Page 10: Directional Control Valve Block Sbe 2 0

yAbmessungen

yyDimensions

yyyCotes d’encombrement

10 Mobile Hydraulics

Page 11: Directional Control Valve Block Sbe 2 0

Mobile Hydraulics 11

Page 12: Directional Control Valve Block Sbe 2 0

Bosch-Automation Technology

Robert Bosch GmbHGeschäftsbereichAutomationstechnikIndustriehydraulikPostfach 30 02 40D-70442 StuttgartTelefax + 49 (0) 7 11 - 8 11 - 18 57

Robert Bosch GmbHGeschäftsbereichAutomationstechnikMobilhydraulikPostfach 30 02 40D-70442 StuttgartTelefax + 49 (0) 7 11 - 8 11 - 17 98

Robert Bosch GmbHGeschäftsbereichAutomationstechnikPneumatikPostfach 30 02 40D-70442 StuttgartTelefax + 49 (0) 7 11 - 8 11 - 89 17

Robert Bosch GmbHGeschäftsbereichAutomationstechnikdidacticBerliner Straße 25D-64711 Erbach/Odw.Telefax + 49 (0) 60 62 - 78 - 8 33

Robert Bosch GmbHGeschäftsbereichAutomationstechnikMontagetechnikPostfach 30 02 07D-70442 StuttgartTelefax + 49 (0) 7 11 - 8 11 - 77 77

Robert Bosch GmbHGeschäftsbereichAutomationstechnikAntriebs- und SteuerungstechnikPostfach 11 62D-64701 ErbachTelefax + 49 (0) 60 62 - 78 - 4 28

Robert Bosch GmbHGeschäftsbereichAutomationstechnikSchraub- und EinpreßsystemePostfach 11 61D-71534 MurrhardtTelefax + 49 (0) 71 92 - 22 - 1 81

Robert Bosch GmbHGeschäftsbereichAutomationstechnikEntgrattechnikPostfach 30 02 07D-70442 StuttgartTelefax + 49 (0) 7 11 - 8 11 - 34 75

Robert Bosch GmbHGeschäftsbereichAutomationstechnikMobilhydraulikPostfach 30 02 40D-70442 StuttgartTelefax + 49 (0) 7 11 - 8 11 - 17 98

Technische Änderungen vorbehaltenWe reserve the right to make technical alterationsSous réserve de modifications techniques