Directional Control Valve
powersolutions.danfoss.com
Directional Control Valves Technical Information: Contents
2 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
PRODUCT OVERVIEW Flexibility of design ........................................................................................................................................ 3Circuit options ................................................................................................................................................. 3Capability .......................................................................................................................................................... 3Actuation options .......................................................................................................................................... 3Modular valves ................................................................................................................................................ 4
FLUIDS AND FILTRATIONFluids ................................................................................................................................................................... 5
Base stock and additives ........................................................................................................................ 5Viscosity ........................................................................................................................................................ 5Filtration ....................................................................................................................................................... 5Return line filtration ................................................................................................................................. 5Cleanliness .................................................................................................................................................. 5
CDS 60 AND 100 Specifications ................................................................................................................................................... 6Typical performance ..................................................................................................................................... 7Inlet covers order code ................................................................................................................................. 8Inlet porting and relief valve options...................................................................................................... 9Mid-inlet flow dividers and combiners order code ..........................................................................10Mid-inlet flow dividers and combiners.................................................................................................11Outlet covers order code ...........................................................................................................................12Outlet porting and plug options ............................................................................................................13Work section order code ..................................................................................................................... 14-17Circuit types....................................................................................................................................................18Spool types .....................................................................................................................................................19Actuation options ................................................................................................................................. 20-21Cabling and electrical options for actuator types G, H, and J ......................................................22Actuation mounting side ..........................................................................................................................22Spool centering and detent options .............................................................................................. 23-24Auxiliary valves ....................................................................................................................................... 25-26Dimensions CDS 100 ...................................................................................................................................26Dimensions CDS 60 .....................................................................................................................................27
APPENDIX 1 — ORDER FORMS
Spool valve order form ...............................................................................................................................28CDS60 and CDS100 specification worksheet .....................................................................................28CDS60 and CDS100 price worksheet ....................................................................................................28
Product overview
FLEXIBILITY OF DESIGN The Danfoss directional control valves are designed to give customer flexibility over a broad range of flow and pressure capabilities. Actuator options include a range of levers, cable actuators, hydraulic and pneumatic pilot controls, two-axis joysticks, and electrohydraulic solenoids. Flow rates range from 0 to 100 l/min [26 US gal/min].
• Parallel circuits• Series circuits• Tandem circuits• Prioritay circuits• Regenerative circuits• Power beyond
• Flow rates from 0 to 100 l/.min [26 US gal/min]• System pressure up to 250 BAR• Up to 12 work sections• 12 cm³/min [0.7 in³/min] leakage
• Handles and levers• Mechanical two-axis joystick• Spool ends• ElectroHydraulic Control (EHC) on/off solenoid• Cable control• Pneumatic pilot control• Dual spool ends
CIRCUIT OPTIONS
CAPABILITY
ACTUATION OPTIONS
Directional Control Valves Technical Information:
3 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: Product overview
Indicates Maximum Working Pressure Rated At 210 bar [3000 psi]
MODULAR VALVESValve model
l/min [US gal/min] Number of Spools
Circuit Page 20 [5] 40 [11] 60 [16] 80 [21] 100 [26]
CDS-100 100 [26] 1 to 12ParallelTandemSeries
CDS-60 60 [16] 1 to 12Parallel Tandem Series
4 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
FLUIDS Hydraulic fluid performs three basic functions in a hydraulic system: It transfers energy, lubricates moving components, and transports heat and contaminants out of the system.
Base stock and additivesDanfoss valves are designed to operate with mineral-based fluids containing oxidation, rust, and foam inhibitors, compatible with fluoroelastomer seals. Consult your fluid supplier for information on seal compatibility.
ViscosityViscosity is the most important property of a hydraulic fluid. It is a measurement of how the fluid resists flow. Low viscosity fluids increase internal leakage; high viscosity fluids increase pressure drop through the valve. Use a fluid that meets the viscosity limits published in this catalog. For specific requirements, see technical data in each section.
TemperatureTemperature affects a fluid’s viscosity. Higher temperature fluid has lower viscosity. Operating at excessive temperatures may have other detrimental effects on your hydraulic fluid. Design your hydraulic system to operate within the specified temperature range. Specific requirements are published in each section.
For more informationFor more information on hydraulic fluid selection refer to Hydraulic Fluids and Lubricants Technical Information, Danfoss publication 520L0463.
Fluids and Filtration
FILTRATIONEffective filtration is critical to a hydraulic system’s performance and working life. Employ system filtration capable of meeting the published requirements in each valve section. Be aware that other components in the system may have more stringent requirements. Design your filtration system to satisfy the requirements of the most sensitive component.
Return line filtrationReturn line filtration is generally adequate for Danfoss valves. We recommend a 10 micron nominal (20 micron absolute) or finer filter. Insure the filter in your system is properly sized and maintained. To facilitate proper filter maintenance, use a pressure gauge or other indicator to signal when it is necessary to change the filter. Never allow filter to reach its bypass condition. Follow the filter manufacturer’s maintenance recommendations.
CleanlinessHydraulic system contamination must not exceed the limits published for each valve. Limits are specified per ISO 4406 (1999). When measuring system contamination, calibrate test equipment in accordance with the ACFTD method.
For more informationFor more information on system filtration, refer to Design Guidelines for hydraulic fluid cleanliness, Danfoss publication 520L0467.
Directional Control Valves Technical Information:
5 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information:
SPECIFICATIONS
CDS 100
CDS 60
Maximum flow (CDS 100) 100 l/min [26.4 US gal/min]
Maximum flow (CDS 60) 60 l/min [15.8 US gal/min]
Work pressure 210 bar [3050 psi]
Maximum pressure 250 bar [3625 psi]
Maximum pressure (outlet section) 40 bar [580 psi]
Temperature range -40º to 80º C [-40 to 176º F]
Recommended fluid type Mineral based hydraulic oil
Recommended viscosity 26-55 mm²/sec (cSt) [123-255 SUS]
Minimum fluid cleanliness (per ISO 4406) 19/16
CDS 60 and 100
6 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
TYPICAL PERFORMANCE
16
14
12
10
8
6
2
4
12 sections
11 sections
10 sections
9 sections
8 sections
7 sections
6 sections
5 sections
4 sections
3 sections
2 sections
1 sections
0
Pres
sure
- b
ar [p
si]
[2.6] [5.3] [7.9] [10] [13] [16] [19] [21] [24] [26]
Flow - l/min [US gal/min]
[232]
[203]
[174]
[145]
[116]
[87]
[58]
[29]
0 10 20 30 40 50 60 70 80 90 100
0 10 20 30 40 50 60 70 80 90 100
250
200
150
100
50
0
Pres
sure
- b
ar [p
si]
[3625]
[2900]
[2176]
[1450]
[725]
[2.6] [5.3] [7.9] [10] [13] [16] [19] [21] [24] [26]
Flow - l/min [US gal/min]
Pressure vs. flow curves for main relief valve
Based on oil temperature of 45°–50°C [113°–122° F]. Viscosity 32 mm²/sec (cSt) [151 SUS]. CDS spool leakage (standard) at 70 bar [1015 psi], 50°C [122°F], ISO VG46: 10 cm³/min [0.61 in³/min]
12 sections
11 sections
10 sections
9 sections
8 sections
7 sections
6 sections
4 sections
3 sections
2 sections
1 sections
5 sections
16
14
12
10
8
6
2
4
0
Pres
sure
- b
ar [p
si]
[232]
[203]
[174]
[145]
[116]
[87]
[58]
[29]
[2.6] [5.3] [7.9] [10] [13] [16]
Flow - l/min [US gal/min]
0 10 20 30 40 50 60
Pressure drop (P-T) CDS 100Pressure drop (P-T) CDS 60
CDS 60 and 100Directional Control Valves Technical Information:
7 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information:
ModelsCode Description
E100 CDS100
E60 CDS60
Port locationsCode Description
A Top port
B Side port, top port plugged
C Top port, with side gauge port (9/16-18UNF)
D Top inlet and outlet ports (use H, I, J on outlet)
Main relief valvesCode Description
A No valve, with plastic plug
B No valve, with special plug
C Valve, with direct valve and external adjustment
D Valve, with direct valve and internal adjustment
E* Valve, pilot operated and external adjustment* on request
INLET COVERS ORDER CODE
Port typesCode 1 2 3 4 5 7 8 X
ThreadsSAE - ORB BSP - Parallel Metric - ISO 6149
Spec
ial p
ortin
g, s
pec
ify#83/4 -16UNF
#107/8 -14UNF
#121 1/16-12UNF
3/8 -19 1/2 -14 M18x1.5 M22x1.5
Model CDS100
Inlet outlet m m Section m m
Model CDS60
Inlet outlet m m m m Section m m m m
availablem on request
E60 A C 2 140/40*Inlet covers order code (example)
CDS 60 and 100
8 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
CDS 60 and 100
mm [in]
D
C
B
P T
11[0.43]
h1 in
h1 in
67[2.64]max
47[1.85]
h 1 in h 7/8 h 7/16
A Top inlet
B Side inlet (top plugged)
C Top inlet, gauge port side (9/16 - 18 UNF)
D* Top inlet and outlet (use with H,I,J, and L outlet covers)
E* Drawing
* On requestP101 798
A Shipping Plug
Port location
INLET PORTING AND RELIEF VALVE OPTIONS
E100 inlet cover
E60 inlet cover
E60 A C 2 140/40*Inlet covers order code (example)
Directional Control Valves Technical Information:
9 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: CDS 60 and 100
ModelsCode Description
S100 CDS 100
S60 CDS 60
PortsCode Description
A Top outlet
B Side outlet, top plugged
C Side outlet for power beyond (top to tank)
D Top outlet (with closed bypass)
E Top outlet (for electrical control)
F Top outlet (for electrical control, with power beyond)
G Side outlet (for electrical control, top plugged)
H* Top plugged
I* Top plugged, use with power beyond
J* Top plugged for electrical control
L* Top plugged for electrical control, use with power beyond
* On request ( use D on inlet)
OUTLET COVERS ORDER CODE
S60 A 2Outlet covers order code (example)
Port typesCode 1 2 3 4 5 7 8 X
ThreadsSAE - ORB BSP - Parallel Metric - ISO 6149
Spec
ial p
ortin
g,
spec
ify
#83/4 -16UNF
#107/8 -14UNF
#121 1/16-12UNF
3/8 -19 1/2 -14 M18x1.5 M22x1.5
Model CDS100
outlet m m
Model CDS60
outlet m m m m
availablem on request
10 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
CDS 60 and 100
mm [in]
B Side outlet (top plugged)
A Top outlet (side plugged)H** Top plugged
30[1.18]
30[1.18]
25[0.98]
C
I
D*
E
J
F
L
G
30.5[1.20]
32[1.25]
CDS 60
CDS 100
30.5[1.20]
32[1.25]
CDS 60
CDS 100
P101 799E
T
PressureBypass
Outlet
PB
T
PBPressureBypass
Outlet
T
PressureBypass
Outlet
T
PressureBypass
Outlet
T
PressureBypass
Outlet
T
PBPressureBypass
Outlet
T
PBPressureBypass
Outlet
T
PBPressureBypass
Outlet
*Typically used for high pressure standby.** On request
OUTLET PORTING AND PLUG OPTIONS
S100 outlet cover
S60 outlet cover
S60 A 2Outlet covers order code (example)
Directional Control Valves Technical Information:
11 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: CDS 60 and 100
WORK SECTION ORDER CODE
ModelA100 CDS 100 body for supporting valves
B100 CDS 100 normal body (no valves)
A60 CDS 60 body for supporting valves
B60 CDS 60 normal body (no valves)
Circuit types, page 151 Parallel (no priority)
2* Tandem (priority)
3* Series (no priority)
Spool types, page 16A 4-way, closed center
B 4-way, open center
C 4-way, closed center, port A plugged
D 4-way, closed center, port B plugged
E 3-way, closed center, port A plugged
F 3-way, closed center, port B plugged
G 4-way, open center, port A plugged
H 4-way, open center, port B plugged
I Float-spool in (use centering option J )
J Float-spool out (use centering option J)
Spool actuation, pages 17–18A No extension
B Female spool end + Clevis
C Male spool end + Tang
D With support (no lever)
E With lever
F Pneumatic (use centering option A)
G Cable with lever
H Cable with joystick (use A for the adjacent body)
I/M With mechanical joystick (use A for the adjacent body)
J Electrical
R Female spool end
S Male spool end
T Female Spool end with adjust
Spool actuation mounting side, page 20 1 Actuator mounted on A port side
2 Actuator mounted on B port side
3 Electrical A and B (use L centering type)
* On request
See cabling and electrical options, page 22.
1 A E 2 A 1 A B 140/40*A100A100Work section order code (example)
12 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
CDS 60 and 100
WORK SECTION ORDER CODE (continued)
Work port side A
Work port side B
Spool centering and detents, page 20-21A Spring centered
B 3 position detent
C Spring centered, detent in A
D Spring centered, detent in B
E Spring centered, detent in A and B
F Spring centered, hydraulic kickout
H Spring centered, female extension
I Spring centered, male extension
J Spring centered, detent in float: use for floatation spool
L Spring centered, use for electrical command
N 2-position detent, spool in
O 2-position detent, spool out
P* With switch, activates spool in
Q* With switch, activates spool in and out
R* With switch, activates two motors
* on request
1 A E 2 A 1 A B 140/40*A100A100Work section order code (example)
Port typesCode 1 2 3 4 5 7 8 X
ThreadsSAE - ORB BSP - Parallel Metric - ISO 6149
Spec
ial p
ortin
g,
spec
ify
#83/4 -16UNF
#107/8 -14UNF
#121 1/16-12UNF
3/8 -19 1/2 -14 M18x1.5 M22x1.5
Model CDS100
Section m m
Model CDS60
Section m m m
available m on request
Auxiliary valves, page 22-23A Plug
B Direct relief with external adjustment (except electrical actuation)
C Direct relief with internal adjustment
D Pilot check valve
E* Flow control valve (Except electrical actuation)
F Anti-cavitation
GDirect relief with anti-cavitation and external adjustment (except electrical actuation)
I Direct relief with anti-cavitation and internal adjustment (electrical only)
J Plug, for 3-way spools
K Plug, for valves D and E
For valves B, C, G, and I, specify pressure and flowExample: B(140/40) Pressure 140 bar flow 40 l/min
* On request
Directional Control Valves Technical Information:
13 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: CDS 60 and 100
A B C D E F G H I/M J
A
B
C
D
E
F
G
H
I
J L
N
O
P
Q
R
• • • • • • • • •• • • • • • • •• • • • • • • •• • • • • • • •• • • • • • • •• • • • • • • •• • • • • • • ••• • • • • • ••• • • • • • • ••• • • • • • • •
•• • • • • • • •• • • • • • • •• • • • • • • ••• • • • • • • ••• • • • • • • ••
Actings
Cen
terin
gs
ACTINGS AND CENTERING COMBINATIONS AVAILABLE
available
14 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: CDS 60 and 100
3 Series circuit (no priority)*
When two or more sections operate simultaneously, only the section closest to the inlet receives flow.
2 Tandem circuit (priority)*
When two or more sections operate simultaneously, flow favors the lowest pressure.
1 Parallel circuit (no priority)
When two or more sections operate simultaneously, the section closest to the inlet receives flow. Return flow feeds the sections downstream.
* on request
CIRCUIT TYPES
P A B A B T
OutletWork sectionsInlet
P101
696
Pressure
Bypass
T TP A AB B
Inlet and Outlet Work Sections Outlet
P101
698
Bypass
P A B A B T
OutletWork sectionsInlet
P101
697
Bypass
Pressure
1 A E 2 A 1 A B 140/40*A100A100Work section order code (example)
15 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
CDS 60 and 100
A B
P T
A B
P T
A B
P T
A B
P T
A B
P T
A B
P T
A B
P T
A B
P T
A B
P T
A B
P T
SPOOL TYPES
P101 743
Tank (x2)
Bypass core
Pressure core
Ref. Description Symbol
A 4-way closed center
B 4-way open center
C 4-way closed center port A plugged
D 4-way closed center port B plugged
E 3-way closed center port A plugged
F 3-way closed center port B plugged
G 4-way open center port A plugged
H 4-way open center port B plugged
I Float spool in (inner inverter)
J Float spool out (outer inverter)
Central body for use with auxiliary valves
Standard central body1 A E 2 A 1 A B 140/40*A100A100
Work section order code (example)
Pump load checkstandard on all bodies
Pump load checkstandard on all bodies
Directional Control Valves Technical Information:
16 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: CDS 60 and 100
ACTUATION OPTIONS
mm [in]
1/8" NPT (2x)
50[1.97]
M10 x 1.5
70[2.76]
66[2.60]CDS 60
CDS 100
M
34[1.34]
8.3[0.33]
ø 8[0.31]
30[1.18] CDS 60
CDS 100
F
34[1.34]
ø 8[0.31]
8.4[0.33]
30[1.18]
6.4[0.25]
CDS 60
CDS 100
CDS 60
CDS 100
F Pneumatic
D With support
B Female spool end (clevis)
E With lever
C Male spool end (tang)
A Without spool end
15º15º
113[4.45]
213[8.39]
M8 x 1.25
M10 x 1.5
8[0.31]
6.5[0.26]
CDS 100
CDS 60
Minimum air pressure CDS 60: 5 bar [73 psi] Minimum air pressure CDS 100: 8 bar [116 psi] Maximum air pressure: 12 bar [174 psi]
1 A E 2 A 1 A B 140/40*A100A100Work section order code (example)
* Default relief setting if not specified
17 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
CDS 60 and 100
ACTUATION OPTIONS (continued)
mm [in]
J Electrical**
90[3.54](Ref.)
117[4.61](Ref.)
96[3.78](Ref.)
12VCC
24VCC 24VCC
12VCC
1.5m
Flying leadsDIN 43650
83[3.27](Ref.)
[5 ft]
Manual override
P101781a
I/M Mechanical joystick
Ø
A
395 [15.55]
70 [2.76]
25° 25°
P101 779
*
30º 30º
ø 6[0.24]
50[1.97]
7[0.28]
7[0.28]
26[1.02]
40[1.57]
50[1.97] 97
[3.82]
118.5[4.66]
48[1.89]
157[6.18]
280[11.02]
H Cable with joystick**G Cable with lever**
1
2
1
2
15º
15º
307[12.09]
1
2
1
2
I
1 A E 2 A 1 A B 140/40*A100A100Work section order code (example)
**See cabling and electrical options, page 20. Standard sections cannot be converted to electrical due to internal pilot. Minimum pilot pressure to actuate: 35 bar [500 psi]
M
Directional Control Valves Technical Information:
18 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: CDS 60 and 100
ACTUATION MOUNTING
A A
BP B T
2 Actuation on B port side (LH inlet shown)1 Actuation on A port side (RH inlet shown)
P101
822
Electrical specificationsVoltage Amperage (A) Resistance (Ω)
12 VDC 1.75 6.85
24 VDC 0.88 27
Power: 21 W
J: Electrical spool voltage and termination options
Voltage A 12 VDC -lead wires B 24 VDC - lead wires E12 VDC - DIN 43650 conn.
F24 VDC - DIN 43650 conn.
Example: how to order A60 - 1AJ3L1 - AC - A 140/40 (12 VDC coil with lead wires)
H: Flexible cable and handle options controls for joystickA
Joystick handle options Without switches
Standard cables 100 - 125 - 150 - 175 - 200 - 250 - 275 - 300 - 325 - 350 - 400 - 450 - 500 cm (other: consult)
Example: how to order A60 - 1AH2A1 - AB - A100 - 140/40 (handle without switches, 100 cm cable)
G: Flexible cable and lock options for spool control leverA B C
Lever lock options Without lock Lock in A and/or B Lock in central position
Standard cables 100 - 125 - 150 - 175 - 200- 250 - 275- 300 - 325 - 350 - 400 - 450 - 500 cm (other: consult)
Example: how to order A60 - 1AG2A1 - AB - A100 - 140/40 (lever without lock, 100 cm cable)
CABLING AND ELECTRICAL OPTIONS FOR ACTUATOR TYPES G, H, AND J
BP B
A A T
AA
B PB
T
P101
796
CDS100 CDS60
CDS100 CDS60
1 A E 2 A 1 A B 140/40*A100A100Work section order code (example)
Force requirementskgf [lbf ] CDS 60 CDS 100
Push/pull min.
2 [4.4] 3.5 [7.7]
Max. tension 250 [551] 250 [551]
SIDE
19 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
CDS 60 and 100
mm [in]
A Spring centered B 3 position detent C Spring center in, detent out
D Spring center out, detent in E Spring centered, detent in A and B F Spring centered, hydraulic kickout
J Spring centered, floatation spool
40[1.57]
32[1.25] CDS 60
CDS 10040
[1.57]
32[1.25] CDS 60
CDS 100
73[2.87]
56[2.20]
CDS 60
CDS 100 73[2.87]
56[2.20]
CDS 60
CDS 100
73[2.87]
56[2.20]
CDS 60
CDS 100
96[3.78]
CDS 60
CDS 100
92[3.62]
Float in
12.5[0.49]
10[0.39]
CDS 60
CDS 100
78[3.07]
65[2.56]
CDS 60
CDS 100
Float out
101[3.97]
CDS 60
CDS 100
82[3.23]
Note: Unlock body sectionrequired for use with hydraulicunlock kit.
Note: Float body section required
Spring forceCDS 60: 145-155 N [32-35 lbf ]CDS 100: 240-245 N [54-55 lbf ]
F
H Spring centered, female extension
Ø 8[0.31]
20.5[0.81]
8.4[0.331]
6.4[0.251]
CDS 60
CDS 100
93 ±5[3.66± 0.2]
88±5[3.46±0.2] CDS 60
CDS 100
I Spring centered, male extension
Ø8
[0.31]
8.3[0.33]
20[0.79]
93 ±5[3.66± 0.2]
88±5[3.46±0.2] CDS 60
CDS 100
SPOOL CENTERING AND DETENT OPTIONS1 A E 2 A 1 A B 140/40*A100A100
Work section order code (example)
* Default relief setting if not specified
Directional Control Valves Technical Information:
20 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: CDS 60 and 100
SPOOL CENTERING AND DETENT OPTIONS (continued)1 A E 2 A 1 A B 140/40*A100A100
Work section order code (example)
32[1.26]
40[1.57]
CDS 60
CDS 100
32[1.26]
40[1.57]
CDS 60
CDS 100
P* Spring centered with switch:activates on spool in
*on request
N Two-position detent:neutral and spool in
O Two-position detent:neutral and spool out
Q* Spring centered with switch:activates on spool in and out
R* Spring centered with switch:activates two motors
P106 330E
32[1.26]
6.5 [0.26]8.0 [0.32]
40[1.57]
CDS 60
CDS 100CDS 60
CDS 100
6.5 [0.26]8.0 [0.32]
CDS 60CDS 100
32[1.26]
6.5 [0.26]8.0 [0.32]
40[1.57]
CDS 60
CDS 100
CDS 60
CDS 100
21 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
CDS 60 and 100
T P
For 3 ways spools. For valves D and E.
G
F
E*
D
C
B
A KJ
70[2.76]Max
12[0.47]
62[2.44]Max
16[0.63]
47[1.85]
67[2.64]Max
10[0.39]
11[0.43]
11[0.43]
7/8
1 in1 in
1 in
1 in
1 in
1 in
5/8
1 in 11/16 7/16
1 in
1 in 11/16 7/16
29[1.14]
Standard
Short version(use with electricalactuation)
I 1 in
29[1.14]
For valves B, C, F, G, and I
P101 746E
* on request
CDS 60Knob
AUXILIARY VALVES
mm [in]
1 A E 2 A 1 A B 140/40*A100A100Work section order code (example)
Central body for use with auxiliary valves
Directional Control Valves Technical Information:
22 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: CDS 60 and 100
mm [in]
Auxiliary valves compatibilityA B C D E F G I J K
A — — — —
B — — — —
C — — —
D — — — — — — — —
E — — — — — — — —
F — — —
G — — — —
I — — — — —
J — — — — —
K — — — — — — —
— Not compatible Compatible
Compatible (EXCEPT electrical) Compatible (ONLY electrical)
AUXILIARY VALVES (continued)
DIMENSIONS CDS 100
A A
BP B T
10[0.39]
5.5[0.22]
R
44.5[1.75]
t 27 N•m20 lbf•ft
152[5.98]
82[3.23]
142[5.59]
100[3.94]
15[0.59]
127[5.00]
Y
X
38[1.49]
46[1.81]
30[1.18]
46[1.81]
25[0.98]
25[0.98]
Reference dimensionsNumber of sections
X Y
1 95 [3.74] 137 [5.39]
2 139 [5.47] 181 [7.13]
3 184 [7.24] 226 [8.89]
4 229 [9.02] 270 [10.63]
5 273 [10.75] 314 [12.36]
6 318 [12.52] 359 [14.13]
7 362 [14.25] 403 [15.87]
8 406 [15.98] 448 [17.64]
9 451 [17.76] 492 [19.37]
10 495 [19.49] 537 [21.14]
11 540 [21.26] 581 [22.87]
12 584 [22.99] 626 [24.65]
1 A E 2 A 1 A B 140/40*A100A100Work section order code (example)
23 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
CDS 60 and 100
r.
BP
TA
B
A
28.5[1.12]
26[1.02]
36[1.42]
13[0.51]
4.5[0.18]
t 18 N•m13 lbf•ft
P101 795
119[4.69]
82[3.23]
14[0.55] 98
[3.86]
120[4.72]
56 74*[2.20] [2.91]
Y
X
38[1.50]
38[1.50]
24[0.94]
32[1.26]
18[0.71]
18[0.71]
Reference dimensionsNumber of sections
X Y
1 72 [2.83] 112 [4.41]
2 108 [4.25] 148 [5.83]
3 144 [5.67] 184 [7.42]
4 180 [7.09] 220 [8.66]
5 216 [8.50] 256 [10.08]
6 252 [9.92] 292 [11.50]
7 288 [11.34] 328 [12.91]
8 324 [12.76] 364 [14.33]
9 360 [14.17] 400 [15.75]
10 396 [15.59] 436 [17.17]
11 432 [17.01] 472 [18.58]
12 468 [18.43] 508 [20.00]
DIMENSIONS CDS 60
AB
77 78
Flatness 0.5-0.8 [0.02 to 0.03] max Flatness 0.5-0.8 [0.02 to 0.03] max
P106 331E
Mounting requirements
Directional Control Valves Technical Information:
24 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
Directional Control Valves Technical Information: Appendix 1 - Order formsD
irect
iona
l Con
trol
Val
ves
CD
S60
and
CD
S100
Spec
ifica
tion
Ord
er F
orm
Con
trol
No.
Sub
sidi
ary/
Dea
ler
Cus
tom
erA
pp
licat
ion
Inle
t Sec
tion
Pain
tO
utle
t Sec
tion
Mo
del
Mo
del
Si
de
Port
Si
zeM
ain
re
lief
Val
ves
Thre
ads
Port
Sid
e Pr
essu
rePo
rt S
ide
Flow
Non
eM
od
elM
od
el S
ize
Port
s O
pti
on
sTh
read
s
Bla
ck P
rimer
Bla
ck P
aint
Wor
k Se
ctio
ns
Wo
rk
sect
ion
Mo
del
Mo
del
Si
zeC
ircu
it
Typ
eSp
oo
l Ty
pes
Spo
ol
Co
ntr
ols
Spo
ol
Co
ntr
ol
Sid
e
Cen
ter
Typ
eTh
read
sA
ux
Val
ves
“A”
Au
x V
alve
s “B
”
Cab
le o
r El
ectr
ical
C
on
tro
l O
pti
on
s
Cab
le
Len
gth
C
enti
-m
eter
s
“A”
Port
Sid
e Pr
essu
re
(Bar
)
“A”
Port
Sid
e Fl
ow (l
/min
)
“B”
Port
Si
de
Pres
sure
(B
ar)
“B”
Port
Si
de
Flow
(l/
min
)
1st
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
11th
12th
Num
ber
of s
ectio
ns =
Pric
e U
S $:
D
eliv
ery:
D
ate:
CDS60 AND CDS100 SPECIFICATION WORKSHEET
25 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101
OUR PRODUCTS
Hydrostatic transmissions
Hydraulic power steering
Electric power steering
Electrohydraulic power steering
Closed and open circuit axial piston pumps and motors
Gear pumps and motors
Bent axis motors
Orbital motors
Transit mixer drives
Planetary compact gears
Proportional valves
Directional spool valves
Cartridge valves
Hydraulic integrated circuits
Hydrostatic transaxles
Integrated systems
Fan drive systems
Electrohydraulics
Microcontrollers and software
Electric motors and inverters
Joysticks and control handles
Displays
Sensors
Danfoss Mobile Power and Control Systems– Market Leaders Worldwide
Danfoss is a comprehensive supplier providing complete systems to the global mobile market.
Danfoss serves markets such as agriculture, construction, road building, material handling, municipal, forestry, turf care, and many others.
We offer our customers optimum solutions for their needs and develop new products and systems in close cooperation and partner ship with them.
Danfoss specializes in integrating a full range of system components to provide vehicle designers with the most advanced total system design.
Danfoss provides comprehensive worldwide service for its products through an extensive network of Global Service Partners strategically located in all parts of the world.
Local address:
Danfoss (US) Company2800 East 13th StreetAmes, IA 50010, USAPhone: +1 515 239-6000Fax: +1 515 239-6618
Danfoss ApSDK-6430 Nordborg, DenmarkPhone: +45 7488 4444Fax: +45 7488 4400
Danfoss-Daikin LTDSannomiya Grand Bldg. 8F2-2-21 Isogami-dori, Chuo-kuKobe, Hyogo 651-0086, JapanPhone: +81 78 231 5001Fax: +81 78 231 5004
Danfoss GmbH & Co. OHGPostfach 2460, D-24531 NeumünsterKrokamp 35, D-24539 Neumünster, GermanyPhone: +49 4321 871-0Fax: +49 4321 871 122
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice.This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are registered trademarks of Danfoss A/S. All rights reserved.
26 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101