dl1067_

Upload: ivan-villaneva

Post on 03-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/12/2019 DL1067_

    1/5

    Unilab Laboratory

    PROGRAMMABLE AUTOMATIC

    POWER SUPPLY UNIT

    DL 1067

  • 8/12/2019 DL1067_

    2/5

    DL 1067

    ver a20130125 2

    GENERAL NOTES

    The DL 1067 power supply unit is suitable for regulating the excitation voltage of electric machines

    and brakes. It is essentially composed of a motor-driven variator, a control board and a single-phase

    bridge.

    It can be either internally controlled in manual mode or externally controlled in automatic mode

    through the data acquisition system and the relevant software.

    TECHNICAL FEAUTURES

    Automatic power supply unit having the following features:

    Continuously adjustable output voltage: 0 to 210 V

    Fixed output current: max. 2A

    Magneto-thermal protection

    Analog signal INPUT terminals and connectors: 0 to 10 V

    OPERATING INSTRUCTIONS

    Check the presence and efficiency of the fuse. Check that the main voltage corresponds to thevoltage shown on the plate (220V + E), then connect the power chord to PR1 socket.

    Operate the mains switch J1. The pilot lamp of the switch on the front panel must turn on.

    MANUAL OPERATION

    Open the switch J1, counter-clockwise turn the voltage potentiometer P1 and set the function switch

    J2 to manual position MAN.Connect a 250V range dc voltmeter to B4 and B5 terminals respecting the polarities.

    Close the switch J1 and, by clockwise turning the potentiometer P1, read the output voltage on the

    voltmeter.

    AUTOMATIC OPERATION

    Remove the supply of the equipment according to previous point.

    Set the switch J2 to AUTO.

    Connect the terminals B1 and B2 to the data acquisition system as required by the (software)program and close the switch J1.

    The 0 to 210V, 2A output is protected by the magneto-thermal switch J3.

  • 8/12/2019 DL1067_

    3/5

    DL 1067

    ver a20130125 3

    LAYOUT OF THE CONTROL DEVICE

    J1 Pilot lamp

    P1 Potentiometer for variable regulation

    J2 Control system selection switch

    J3 Magneto-thermal protection of variatorB1, B2 Terminals for system connection

    B3 Ground terminal

    B4, B5 Output terminals

    PR1 Main socket with protection fuse (rear of panel)

  • 8/12/2019 DL1067_

    4/5

    DL 1067

    ver a20130125 4

    MAINTENANCE

    The unit doesnt require any special maintenance operation.

    It can be checked without any difficulty.

    In case of faulty operation, DISCONNECT THE MAINS CONNECTION.Then open the unit and access to the inside.

    It is enough to check that the components and the connections are efficient according to the electric

    diagram.

    The motor is controlled through an electronic board on which a fuse-holder with fuse is assembled.

    Check the fuse and the connections. If the equipment doesnt operate it is suggested not to change

    the calibrations of the electronic board, otherwise the guarantee would be lost.

  • 8/12/2019 DL1067_

    5/5

    1996 - 2013DE LORENZO SPA - Printed in Italy - All right reserved

    DE LORENZO SPA

    V.le Romagna, 20 - 20089 Rozzano (MI) Italy

    Tel. ++39 02 8254551 - Fax ++39 02 8255181

    E-mail:info

    @delorenzo.itWeb sites: www.delorenzoglobal.com - www.technical-education.it -

    www.delorenzoenergy.com