    Electrical Power Engineering

    POWER CIRCUIT BREAKERDL 2108T02

  • 8/11/2019 DL2108T02

    2/10

  • 8/11/2019 DL2108T02

    3/10

  • 8/11/2019 DL2108T02

    4/10

    DL 2108T02

    ver b20130115 3

    3. PUSH-BUTTON CONTROL

    The PLC and RELAY control inputs must be low (short - circuit).

  • 8/11/2019 DL2108T02

    5/10

    DL 2108T02

    ver b20130115 4

    When the module is supplied with the auxiliary voltage, the power breaker K is normally open.

    Pressing the push-button S on the RS flip-flop is set and the power breaker K is closed.

    At SIGNAL OUTPUT terminals is present a high level, TTL compatible.

    Pressing the push-button S off the RS flip-flop is reset and the power breaker driving is inhibited.

  • 8/11/2019 DL2108T02

    6/10

    DL 2108T02

    ver b20130115 5

    4. RELAY CONTROL

    The PLC control input must be low (short-circuit).

    The RELAY control input is connected to a switching contact, normally closed.

  • 8/11/2019 DL2108T02

    7/10

    DL 2108T02

    ver b20130115 6

    When the module is supplied with the auxiliary voltage, the power breaker K is normally open.

    With closed RELAY contact, pressing the push-button S on the RS flip-flop is set and the power breaker K is closed.

    When the RELAY contact is open the RS flip-flop is reset and the power breaker driving is

    inhibited.

    Only when the RELAY contact is closed again it is possible to drive the power breaker K by meansof the push-button S on.

  • 8/11/2019 DL2108T02

    8/10

    DL 2108T02

    ver b20130115 7

    5. PLC CONTROL

    The RELAY control input must be low (short-circuit).

    The PLC control input is connected to a switching contact, normally closed.

  • 8/11/2019 DL2108T02

    9/10

    DL 2108T02

    ver b20130115 8

    When the module is supplied with the auxiliary voltage the power breaker K is normally open.

    With closed PLC contact, pressing the push-button S on the RS flip-flop is set and the power breaker K is closed.

    When the PLC contact is open the drive coil of the power breaker is inhibited and the power contactK is open. The RS flip-flop remains in set state and when the PLC contact is closed again the power

    breaker K is closed.

    Only pressing the push-button S off the RS flip-flop is reset and the power breaker driving isinhibited.